NSC110AD Manual

NSC110AD
NSC110AD User’s Manual (2014.04.16 ver.2.0)

User’s Manual
USER’S MANUAL
SALANITY CONTROLER
(Model : NSC110AD)

NIT-QP-505-01 Ver 1.0(2011.11.01)


1.
Product notes NSC110AD
(2014.04.16 ver.2.0)

Product Notes
CAUTION
1. Please read the whole manual before using it.

2. Be sure to follow the cautions for safety.

3. Please connect to ground for safety.

4. Don't disassemble, repair and remodeling


except service technician.

5. Must not be used to over rated output


capacity.

6. The contents of this manual can be changed


to improve products version and quality
without notice.

NIT-QP-505-01 Ver 1.0(2011.11.01)


2.
Manual table of contents NSC110AD
(2014.04.16 ver.2.0)

Manual Table of
Table of Contents

Contents
Page
Chapter 1 Safety Precautions
Section 1 Warnings and Cautions …..………..….……..…4
1. Warnings..………………………………………………..………..4
2. Cautions.……………….…………………………………..………4

Chapter 2 Installation and Wiring


Section 1 Installation …..…………………….…….…..…........5
1. Check specification…..…………………………….…..…….5
a. Specifications …………..……………………..…….……….5
2. Before Installation.………..………….……………….……...5
3. Dimensions …………..…………...………….…..……….…….6
a. Dimensions of the product.…..………………….……6
4. Connections …………………………….…..….………….……7
a. Connections …………………….…….…..……………….....7
5. Features and Description..…….…………..….…..….…..8
a. Key Features .…………….……….…………..………….…..8
b. Periodic Checks…………….……….…………………… …8

Chapter 3 Operation and driving


1. Operation and driving ………………….………..……..…9
a. Button Function ...…………..………….………..…………9
b. LCD main screen configuration .……………….…..10
c. LCD main screen configuration description .…10

NIT-QP-505-01 Ver 1.0(2011.11.01)


3.
NSC110AD
Chapter 1 Safety Precautions (2014.04.16 ver.2.0)

Section 1 Warnings and Cautions

Chapter 1 Precautions for


Logo Description
If you do not follow the instructions, this may result
in death or serious injury.

safety
Caution
If you do not follow the instructions, personal injury,
fire, or explosion, can result in equipment damage
or malfunction.
Warning

Warning
1. Warnings
1) Do not operate the product with wet hands.
2) Please be grounded for safety.
3) Do not install in the place where humid and rain, snow place.
4) Don't disassemble, repair and remodeling except service technician.
5) Must be followed rated output capacity.

Caution

2. Precautions

1) Be sure to check the product specifications.

NIT-QP-505-01 Ver 1.0(2011.11.01)


4.
Chapter 2 Installation and Wiring
NSC110AD
(2014.04.16 ver.2.0)

Section 1 Installation
1. Check specification

and Wiring
Chapter 2 Installation
1) Specifications
Items Contents

Power AC210~AC230V 50/60 Hz

Current 50mA

LCD 16×01 C LCD

Appearance 165mm(W)×160mm(H)×88mm(D)

Range 0~200PPM

Accuracy ±2.5%

Coverage 0~100℃(±1%)

Operating Pressure 5Kg/㎠

2. Before Installation

Warning
1. Before installing the product, read the instructions and
follow the installation environment.

2. Installing on the panel of metal and non-combustible.

3. Do not install in direct sunlight.

4. Do not install near flammable.

5. Do not install in a location where vibration.

6. Fixing all four sides of the product to tighten the bolts.

7. Do not allow foreign objects to enter the wire, pieces of steel,


wire, and dust.

8. Do not install in hot and humid plase.

NIT-QP-505-01 Ver 1.0(2011.11.01)


5.
Chapter 2 Installation and Wiring
NSC110AD
(2014.04.16 ver.2.0)

3. Dimensions
1) Dimensions of the product

and Wiring
Chapter 2 Installation
Make sure product shape and make enough
space for ventilation.
Caution

Figure - Dimensions

NIT-QP-505-01 Ver 1.0(2011.11.01)


6.
Chapter 2 Installation and Wiring
NSC110AD
(2014.04.16 ver.2.0)

4. Connections
1. Connections

and Wiring
Chapter 2 Installation
Before connections,
Warning the power is must turned off.

Figure-Dimensions
1) Power input connections
The connecter numbers 1, 2, 3 are used to connect according to power source
AC220V, AC110V
a. Power AC220V connects number 1, 3.
b. Power AC110V connects number 1, 2.
NIT-QP-505-01 Ver 1.0(2011.11.01)
7.
Chapter 2 Installation and Wiring
NSC110AD
(2014.04.16 ver.2.0)

2) Sensor Connections
Salinity sensor has Salinity sensor lines and Temperature
sensor lines, GND line

and Wiring
Chapter 2 Installation
a. 11(SALT) : Salinity Sensor wiring(White)
b. 12(TEMP) : Temperature Sensor wiring(Red)
c. 13(GND) : GND wiring(Black)
3) Alarm Connections
In case of need to connect to alarm, connect to terminal 5, 7 for
controller.

4) Solenoid connections
Solenoid wiring should connect to terminal 8, 9, 10 for controller.

5. Features and Description


a. Key Features
Salinity controller is a equipment for measuring salinity of distilled
water from fresh water generator.
And Salinity controller is sensing salinity of distilled water.
In case distilled water is higher than salinity setting ppm value,
The solenoid valve is controlled by salinity controller.
The solenoid valve returns the distilled water to fresh water generator.
In case distilled water is lower than salinity setting ppm value.
The distilled water is supplied by solenoid valve.

b. Periodic Checks
Irregular or Error can occur due to scale adhesion,
the Probe must be kept clean.

NIT-QP-505-01 Ver 1.0(2011.11.01)


8.
NSC110AD
Chapter 3 Operation and driving (2014.04.16 ver.2.0)

1. Operation and driving


1) Button Function

Chapter 3 Operation and


driving
그림 전면 패널 설명

No. Contents Description


The button is used to return to first screen, after each

① function setting

SET button is used to select to change setting value or test.


Solenoid and Alarm , Run Hours, Temperature.

② When SET button is pressed, the display is changed.


If EXIT button is pressed, display is moved to first screen from
each setting mode.

UP button is used to Increase setting value when the screen


moved to setting screen by SET button.

DOWN button is used to decrease setting value when the


screen moved to setting screen by SET button.

ALARM OFF is used to alarm setting button for on and off.

⑤ In case ALARM OFF is setting as off, the alarm relay does not
work.

NIT-QP-505-01 Ver 1.0(2011.11.01)


9.
NSC110AD
Chapter 3 Operation and driving (2014.04.16 ver.2.0)

2) LCD Main Configuration

a. Solenoid(Unit : ppm)

Chapter 3 Operation and


a) This is used to change the solenoid value.
b) When the sensing value is excess than Solenoid value,
The Relay is works.

b. Alarm(Unit : ppm)

driving
a) This is used to set Alarm ppm.
b) When excess than alarm ppm setting value,
The alarm relay is works.

c. Run Hour(Unit : hour)


a) Total operation hour will be displayed.

d. Temp(Unit : ℃)
a) Distillate water temperature will be displayed.

e. Test Salt(Unit : ppm)


a) This is used to test the controller condition.

NIT-QP-505-01 Ver 1.0(2011.11.01)


10.
NSC110AD
Chapter 3 Operation and driving (2014.04.16 ver.2.0)

Explanation of LCD Main screen configuration

Button For Display Description

Chapter 3 Operation and


1. The initial screen
Salinity : 0ppm When the power turned on, The controller is
display the sensing value of salinity sensor.

driving
2. SOL V/V work settings
Press SET button one time,
Solenoid : 0ppm Solenoid value is changed by keys.
(Setting range : 0~200ppm)
ex) In excess of ppm, Solenoid Relay is
worked
3. Alarm operation settings

Alarm : 15ppm Press SET button two times,


Alarm value is changed by keys.
(Setting range : 0~200ppm).
ex) In excess of ppm, alarm Relay is worked
4. Total Operation Hour (Run Hour)
Run Hour: -1h SET button is pressed three times, the total
operation time is displayed.

5. The current temperature

Temp : 0dig SET button is pressed four times, the current


temperature is displayed
.

6. Test

TestSalt : 0ppm On TestSalt mode after pressing set button


five times, The ppm value can be changed by
button, Alarm and relay in the
controller can be check to work (When the
setting value is larger than Alarm and
solenoid setting value, The relay in the
controller will be operated.)

NIT-QP-505-01 Ver 1.0(2011.11.01)


11.
Index NSC110AD
(2014.04.16 ver.2.0)

1. Figure Index

Figure number

Figure shape dimensions ………………………………………………..……6


Figure connections…………………………………………………….…….…….7

Index
Figure front panel and explanation .……………………………..……...9

2. Concordance

The Term
-A-
Alarm Connections ..………………………………………………………..……..8
Alarm …………………………………………………………………………….…….10
-B-
Button Functions …………………..………………………………………………..9
Before installation .…………………………………………………………………5
-C-
Check specification……………………..………………………………….………..5
Cautions ..……………………………………………………………………………….4
-D-
Dimensions ……………………………………………………………………………..6
Dimensions of the product …………………………………………………….6
-F-
Features and description …………………………………………….………….8
-I-
Installation……………………………………………………………………………5 , 9
Installing and Wiring .……………………………………………….……………..5
-K-
Key Features ..……………………………………………………………….………….8
-L-
LCD Main Display Configuration .…………………………………………..10
LCD Main Configuration Description ……………………………………..11
-S-
Sensor Connections .……………………………………………………….……….8
Specifications …………………………………………………………………..……….5
Safety precautions …………………………………………………………………...4

NIT-QP-505-01 Ver 1.0(2011.11.01)


12.
Index NSC110AD
(2014.04.16 ver.2.0)

The Term
-O-
Operation and driving …………………………………………………………….9
-P-

Index
Power input connections .……………………………………………………….7
-R-
Run Hour ………………………………………………………………………………10
-S-
Solenoid Connections ……………………………………………………………8
Solenoid ………………………………………………………………………………..10
-T-
Temp ………………………………………………………………………….………….10
Test Salt …………………………………………………………………….……….….10
-W–
Warnings and cautions ……………………………………………..……………..4
Warnings ….…………………………………………………….…………..…………….4
Wiring Connections .………..…………………………………………………...…..7
Wiring Connections .……………..……………………………………………...…..7

NIT-QP-505-01 Ver 1.0(2011.11.01)


13.
◆ Product Warranty NSC110AD
(2014.04.16 ver.2.0)

Product Model


Serial NO. Purchase

Product Warranty
Name

Address
Your dealer
Telephone

Warranty Period and Scope

● Warranty is 1 year from the date of purchase.


● The meaning of the guarantee is limited to the purchase of products.
Damages caused by the product purchased will be excluded from the warranty
and Warranty is valid only in the Republic of Korea

Free Service

● In case the products are out of order in terms of guarantee, The products will be repaired
at our designated service center with free.

Paid Services

Incorrect use of the product, or any failure caused by bad maintenance and service must be paid
for damage.
● A person who is not specified, the repairer will repair the product or service failures caused by
● Careless handling of consumers in the event of failure to
● Manual does not comply with the warnings and precautions in the event of failure
● If a fault occurs by natural disasters.(Fire, earthquake, flood, lightning, flood, etc.)
● Free service period has elapsed.