Proposed Rest House Standard Load Calculation (Wiring Design Analysis)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PROPOSED REST HOUSE

STANDARD LOAD CALCULATION (WIRING DESIGN ANALYSIS)

Project: Proposed 2-Storey Rest House with Basement, Attic & Swimming Pool
Location: Block 5, Lot 32, The Cliffside, Anvaya Cove, Barrio Sabang, Morong, Bataan
Owner: Mr. & Mrs. Felipe T. Tan

WIRING DESIGN FOR RESIDENTIAL

Total Floor Area: 601.00 m²

1. LIGHTING & RECEPTACLE LOAD; Table 2.20.2.3


Unit Load Area
Type of Occupancy VA
(VA)/m² (m²)
a. Dwelling Unit 24.00 601.00 14,424.00

2. SMALL-APPLIANCE BRANCH CIRCUIT; Art. 2.20.3.13(A)


Load/Ckt No. of
Description VA
(VA) Ckts
a. Small Appliance Circuit 1500.00 11.00 16,500.00

3. LAUNDRY BRANCH CIRCUIT; Art. 2.20.3.13(B)


Load/Ckt No. of
Description VA
(VA) Ckts
a. Laundry Circuit 1500.00 1.00 1,500.00

SUB-TOTAL 32,424.00
Table 2.20.3.3
Application of Demand Factor D.F. (%)
First 3000 VA 100.00% 10,000.00
From 3001 to 120,000 VA 35.00% 7,848.40

SUB-TOTAL 17,848.40 VA

4. FASTENED-IN-PLACE APPLIANCES; Art. 2.20.3.14


Description Rating (W) Qty. VA
a. 3.5kW Water Heater 3,500.00 5.00 17,500.00
b. Refrigerator 380.00 1.00 380.00
c. Refrigerator 180.00 1.00 180.00
d. 2Hp Pool Pump 2,760.00 1.00 2,760.00

SUB-TOTAL 20,820.00 VA

Art. 2.20.3.14
Application of Demand Factor D.F. (%) Qty. VA
If fewer than four units 100.00%
If four or more units 75.00% 8.00 15,615.00

SUB-TOTAL 15,615.00 VA
5. RANGES, OVENS, COOKTOPS & OTHER HOUSEHOLD COOKING APPLIANCES
OVER 1,750W OR 1-¾ kW; Art. 2.20.3.16
Description Rating (W) Qty. VA
a. Electric Range 2200.00 1.00 2,200.00
b. Range Igniter 200.00 1.00 200.00
b. Electric Range Hood 225.00 2.00 450.00

Table 2.20.3.16
Application of Demand Factor D.F. (%) Qty.
Column A (Less Than 3.5kW) 80.00% 1.00 1,760.00

SUB-TOTAL 2,210.00 VA

6. AIR-CONDITIONING SYSTEM; Art. 2.20.4.3(C), 4.40.1.6(A)


Description FLA (A) Qty. VA
a. 1.5Hp Window Type ACU 5.50 1.00 1,265.00
b. 2Hp Window Type ACU 7.30 4.00 6,716.00
c. 2.5Hp Window Type ACU 11.60 1.00 2,668.00

SUB-TOTAL 10,649.00 VA

7. LARGEST MOTOR; Art. 4.30.2.4, 4.40.1.7


Volt-Ampere of Largest Motor VA D.F. (%) VA
a. 2Hp Pool Pump 2,760.00 25.00% 690.00

SUB-TOTAL 690.00 VA

8. TOTAL VOLT-AMPERE (VA) DEMAND LOAD 47,012.40 VA

9. MINIMUM SIZE OF SERVICE FEEDER (A): 204.40 A

10. SIZE OF MAIN SERVICE FEEDER CONDUCTOR


USE: 2-125 mm² THHN + 1-50 mm² THHN (GROUND) IN 90mm⌀ PVC

11. SIZE OF SERVICE EQUIPMENT:


250AT, 250AF, 2-POLE, 85kAIC MCCB RATED AT 230 Vac