SEN00790-02 40 Troubleshooting

Failure code [CA272] IMV/PCV1 Open Error


Action code Failure code IMV/PCV1 Open Error
Trouble
E11 CA272 (Engine controller system)
Contents of
• Open error was detected in PCV1 circuit of supply pump.
trouble
Action of
• None in particular.
controller
Problem that
appears on
machine
Related
information

Cause Standard value in normal state/Remarks on troubleshooting


aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch ON.
Defective supply pump PCV1 (male) Resistance
1 PCV1
(Internal disconnection) Between (1) – (2) 2.3 – 5.3 z
Between (1), (2) –
Min. 1 Mz
chassis ground
aPrepare with starting switch OFF, then carry out troubleshooting with-
Disconnection in wiring out turning starting switch ON.
harness
Wiring harness between ENG (female) (4) – Resis-
2 (Disconnection in wiring or Max. 1 z
PCV1 (female) (1) tance
defective contact in con-
nector) Wiring harness between ENG (female) (5) – Resis-
Possible causes Max. 1 z
PCV1 (female) (2) tance
and standard
value in normal aPrepare with starting switch OFF, then carry out troubleshooting with-
state out turning starting switch ON.
Ground fault in wiring har- Between wiring harness of ENG (female) (4) –
Resis-
ness PCV1 (female) (1) and chassis ground and Max. 1 Mz
3 tance
(Short circuit with GND cir- chassis ground
cuit) Between wiring harness of ENG (female) (5) –
Resis-
PCV1 (female) (2) and chassis ground and Max. 1 Mz
tance
chassis ground
aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch ON.
ENG (female) Resistance
4 Defective engine controller
Between (4) – (5) 2.3 – 5.3 z
Between (4), (5) –
Min. 1 Mz
chassis ground

Circuit diagram related to supply pump PCV1