SEC-02 Security Fencing
4.13.22. Alll posts, except brace posts, shall be installed in a vertical
position, plumb and in line.
4.13.2.3. Footings forall posts shall extend 100 mm below the end of the
post
4.13.2.4, The soil shall be moistened before placing the concrete.
4.13.2.5. All line posts shall be equally spaced at intervals of not more
than 3 m.
4.13.26. Terminal posts (Comer, End, Gate or Pull) shall be installed at
the beginning and end and at a maximum of 90 m intervals of
fence fabric and at changes in vertical and horizontal
alignments exceeding 22%° deflection angle.
4.13.2.7. Except for gateposts, the exposed surface of the concrete
foundation shall be set 25 mm above surrounding grade with a
smooth 13 mm crown, sloping away from the post.
4.13.2.8, Before placing components such as fabric, rails, tension wire,
and gates, the concrete shall have cured a minimum of 7 days
unless the concrete reaches at least 75 percent of its design
strength.
4.13.29. Line, comer, pull, and terminal posts shall be set vertically in
cylindrical concrete foundations in accordance with Table 2
Comment:
The values in Table 2 below are the minimum; site soil
conditions may require a bigger size in diameter, depth, or
embedment
‘Table 2- Post Installation Schedule
Post Type Foundation] Foundation | Post Enabedment
Diamefer(mm)_| Depth (a) _| (my
Fence Post
Line Post_ [350 10 oo
Comer, Pull &
Terminal Posts _| #50 i 10
Brace Post | 300 10 05
Gatepost OD (mm)
Tieve Date IDGTAT2OSE010