Post Tension Stressing Log

PAGE 1 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
23.01 UNIFORM 1 5/8 1 3/8 1 3/8 -15%
23.02 UNIFORM 1 5/8 1 3/8 1 3/8 -15%
24.01 UNIFORM 1 5/8 1 3/8 1 3/8 -15%
24.02 UNIFORM 1 5/8 1 3/8 1 3/8 -15%
24.03 UNIFORM 1 5/8 1 3/8 1 3/8 -15%
40.01 UNIFORM 2 1/8 2 2 -6%
40.02 UNIFORM 2 1/8 2 1/8 2 1/8 0%
40.03 UNIFORM 2 1/8 2 2 -6%
41.01 UNIFORM 4 3/8 4 3/4 4 3/4 9%
41.02 UNIFORM 4 3/8 4 3/4 4 3/4 9%
41.03 UNIFORM 4 3/8 4 3/4 4 3/4 9%
42.01 UNIFORM 4 3/8 4 1/2 4 1/2 3%
42.02 UNIFORM 4 3/8 4 5/8 4 5/8 6%
42.03 UNIFORM 4 3/8 4 5/8 4 5/8 6%
43.01 UNIFORM 4 3/8 4 3/4 4 3/4 9%
43.02 UNIFORM 4 3/8 4 3/4 4 3/4 9%
43.03 UNIFORM 4 3/8 4 5/8 4 5/8 6%
44.01 UNIFORM 4 3/8 4 3/4 4 3/4 9%
44.02 UNIFORM 4 3/8 4 3/4 4 3/4 9%
44.03 UNIFORM 4 3/8 4 3/4 4 3/4 9%
44.04 UNIFORM 4 3/8 4 1/4 4 1/4 -3%
45.01 UNIFORM 4 3/8 4 1/2 4 1/2 3%
45.02 UNIFORM 4 3/8 4 5/8 4 5/8 6%
45.03 UNIFORM 4 3/8 4 3/4 4 3/4 9%
71.01 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
71.02 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
72.01 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
72.02 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
73.01 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
Post Tension Stressing Log
PAGE 2 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
74.01 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
74.02 UNIFORM 1 5/8 1 1/2 1 1/2 -8%
75.01 BANDED 5 1/4 5 1/2 5 1/2 5%
75.02 BANDED 5 1/4 5 3/4 5 3/4 10%
75.03 BANDED 5 1/4 5 3/4 5 3/4 10%
75.04 BANDED 5 1/4 5 1/2 5 1/2 5%
76.01 BANDED 5 1/4 5 1/2 5 1/2 5%
76.02 BANDED 5 1/4 5 1/2 5 1/2 5%
76.03 BANDED 5 1/4 5 1/2 5 1/2 5%
76.04 BANDED 5 1/4 5 1/2 5 1/2 5%
77.01 BANDED 3 3 1/8 3 1/8 4%
77.02 BANDED 3 3 1/8 3 1/8 4%
77.03 BANDED 3 3 1/8 3 1/8 4%
77.04 BANDED 3 3 1/8 3 1/8 4%
78.01 UNIFORM 6 1/2 6 3/4 6 3/4 4%
78.02 UNIFORM 6 1/2 6 3/4 6 3/4 4%
78.03 UNIFORM 6 1/2 6 3/4 6 3/4 4%
79.01 UNIFORM 6 1/2 6 3/4 6 3/4 4%
79.02 UNIFORM 6 1/2 6 3/4 6 3/4 4%
80.01 UNIFORM 6 1/2 7 7 8%
80.02 UNIFORM 6 1/2 6 3/4 6 3/4 4%
80.03 UNIFORM 6 1/2 6 1/2 6 1/2 0%
81.01 UNIFORM 6 1/8 6 1/4 6 1/4 2%
81.02 UNIFORM 6 1/8 6 3/8 6 3/8 4%

82.01 UNIFORM 4 4 4 0%
83.01 UNIFORM 4 3 3/4 3 3/4 -6%
84.01 UNIFORM 4 4 4 0%
85.01 UNIFORM 6 1/8 6 1/4 6 1/4 2%
85.02 UNIFORM 6 1/8 6 3/8 6 3/8 4%
Post Tension Stressing Log
PAGE 3 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
86.01 UNIFORM 6 1/8 6 1/8 6 1/8 0%
86.02 UNIFORM 6 1/8 6 6 -2%
86.03 UNIFORM 6 1/8 6 6 -2%
87.01 UNIFORM 5 1/2 5 3/4 5 3/4 5%
87.02 UNIFORM 5 1/2 5 3/4 5 3/4 5%
88.01 UNIFORM 5 1/2 6 6 9%
88.02 UNIFORM 5 1/2 5 3/4 5 3/4 5%
89.01 UNIFORM 5 1/2 6 6 9%
89.02 UNIFORM 5 1/2 6 6 9%
89.03 UNIFORM 5 1/2 5 3/4 5 3/4 5%
90.01 UNIFORM 6 6 1/2 6 1/2 8%
90.02 UNIFORM 6 5 3/4 5 3/4 -4%
91.01 UNIFORM 6 6 1/2 6 1/2 8%
91.02 UNIFORM 6 6 6 0%
92.01 UNIFORM 6 6 1/4 6 1/4 4%
92.02 UNIFORM 6 6 6 0%
92.03 UNIFORM 6 6 1/4 6 1/4 4%
93.01 UNIFORM 2 1/8 2 1/4 2 1/4 6%
94.01 UNIFORM 2 1/8 2 1/4 2 1/4 6%
95.01 UNIFORM 1 5/8 1 5/8 1 5/8 0%
95.02 UNIFORM 1 5/8 1 3/4 1 3/4 8%
95.03 UNIFORM 1 5/8 1 5/8 1 5/8 0%
95.04 UNIFORM 1 5/8 1 7/8 1 7/8 15%
96.01 UNIFORM 1 3/4 1 3/4 1 3/4 0%
96.02 UNIFORM 1 3/4 1 3/4 1 3/4 0%
96.03 UNIFORM 1 3/4 1 3/4 1 3/4 0%
97.01 UNIFORM 1 3/4 1 3/4 1 3/4 0%
97.02 UNIFORM 1 3/4 1 3/4 1 3/4 0%
97.03 UNIFORM 1 3/4 1 3/4 1 3/4 0%
97.04 UNIFORM 1 3/4 1 3/4 1 3/4 0%
Post Tension Stressing Log
PAGE 4 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
98.01 UNIFORM 1 3/4 1 3/4 1 3/4 0%
98.02 UNIFORM 1 3/4 1 3/4 1 3/4 0%
98.03 UNIFORM 1 3/4 1 3/4 1 3/4 0%
98.04 UNIFORM 1 3/4 1 3/4 1 3/4 0%
99.01 UNIFORM 1 3/4 1 3/4 1 3/4 0%
99.02 UNIFORM 1 3/4 1 3/4 1 3/4 0%
99.03 UNIFORM 1 3/4 1 1/2 1 1/2 -14%
100.01 UNIFORM 1 3/4 2 2 14%
100.02 UNIFORM 1 3/4 1 3/4 1 3/4 0%
100.03 UNIFORM 1 3/4 1 3/4 1 3/4 0%
100.04 UNIFORM 1 3/4 1 3/4 1 3/4 0%
101.01 UNIFORM 5 1/2 5 1/2 5 1/2 0%
101.02 UNIFORM 5 1/2 5 3/4 5 3/4 5%
102.01 UNIFORM 5 1/2 5 7/8 5 7/8 7%
102.02 UNIFORM 5 1/2 6 6 9%
102.03 UNIFORM 5 1/2 5 3/4 5 3/4 5%
103.01 UNIFORM 5 1/2 5 1/2 5 1/2 0%
103.02 UNIFORM 5 1/2 5 3/4 5 3/4 5%
104.01 UNIFORM 5 1/2 5 7/8 5 7/8 7%
104.02 UNIFORM 5 1/2 5 3/4 5 3/4 5%
104.03 UNIFORM 5 1/2 5 3/4 5 3/4 5%
105.01 UNIFORM 2 7/8 3 3 4%
105.02 UNIFORM 2 7/8 3 1/8 3 1/8 9%
106.01 UNIFORM 2 7/8 3 1/8 3 1/8 9%
106.02 UNIFORM 2 7/8 3 1/8 3 1/8 9%
107.01 UNIFORM 3 3 1/4 3 1/4 8%
107.02 UNIFORM 3 3 3/8 3 3/8 13%
Post Tension Stressing Log
PAGE 5 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)

112.01 UNIFORM 2 3/4 2 3/4 2 3/4 0%


112.02 UNIFORM 2 3/4 3 3 9%
112.03 UNIFORM 2 3/4 3 3 9%
113.01 UNIFORM 2 3/4 3 3 9%
113.02 UNIFORM 2 3/4 3 3 9%
113.03 UNIFORM 2 3/4 3 3 9%
114.01 UNIFORM 2 3/4 3 3 9%
114.02 UNIFORM 2 3/4 2 7/8 2 7/8 5%
114.03 UNIFORM 2 3/4 3 3 9%
115.01 UNIFORM 2 3/4 3 3 9%
115.02 UNIFORM 2 3/4 3 3 9%
115.03 UNIFORM 2 3/4 3 3 9%
115.04 UNIFORM 2 3/4 3 3 9%
116.01 UNIFORM 1 3/4 1 7/8 1 7/8 7%
117.01 UNIFORM 1 3/4 1 7/8 1 7/8 7%
118.01 UNIFORM 2 5/8 2 3/4 2 3/4 5%
118.02 UNIFORM 2 5/8 2 3/4 2 3/4 5%
118.03 UNIFORM 2 5/8 2 3/4 2 3/4 5%
118.04 UNIFORM 2 5/8 3 3 14%
119.01 UNIFORM 2 5/8 2 7/8 2 7/8 10%
119.02 UNIFORM 2 5/8 2 7/8 2 7/8 10%
119.03 UNIFORM 2 5/8 2 3/8 2 3/8 -10%
119.04 UNIFORM 2 5/8 2 1/2 2 1/2 -5%
Post Tension Stressing Log
PAGE 6 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
6.01 BANDED 8 7/8 8 3/4 8 3/4 -1%
6.02 BANDED 8 7/8 8 3/4 8 3/4 -1%
6.03 BANDED 8 7/8 9 1/8 9 1/8 3%
7.01 BANDED 8 7/8 9 1/8 9 1/8 3%
7.02 BANDED 8 7/8 8 5/8 8 5/8 -3%
7.03 BANDED 8 7/8 8 3/4 8 3/4 -1%
8.01 BANDED 8 7/8 8 5/8 8 5/8 -3%
8.02 BANDED 8 7/8 8 3/4 8 3/4 -1%
8.03 BANDED 8 7/8 9 1/8 9 1/8 3%
8.04 BANDED 8 7/8 9 1/4 9 1/4 4%
9.01 BANDED 8 7/8 9 1/8 9 1/8 3%
9.02 BANDED 8 7/8 9 1/4 9 1/4 4%
9.03 BANDED 8 7/8 9 1/4 9 1/4 4%

30.01 BANDED 4 7/8 5 1/4 5 1/4 8%


31.01 BANDED 4 7/8 5 1/4 5 1/4 8%
31.02 BANDED 4 7/8 5 1/4 5 1/4 8%

32.01 BANDED 5 1/4 5 5/8 5 5/8 7%


32.02 BANDED 5 1/4 5 5/8 5 5/8 7%
32.03 BANDED 5 1/4 5 1/2 5 1/2 5%
10.01 BANDED 9 7/8 10 1/4 10 1/4 4%
10.02 BANDED 9 7/8 10 10 1%
10.03 BANDED 9 7/8 10 10 1%
11.01 BANDED 9 7/8 10 10 1%
11.02 BANDED 9 7/8 10 1/4 10 1/4 4%
11.03 BANDED 9 7/8 10 10 1%
Post Tension Stressing Log
PAGE 7 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
16.01 BANDED 8 7 7/8 7 7/8 -2%
16.02 BANDED 8 8 1/4 8 1/4 3%
16.03 BANDED 8 8 1/8 8 1/8 2%
17.01 BANDED 8 7 7/8 7 7/8 -2%
17.02 BANDED 8 7 3/4 7 3/4 -3%
17.03 BANDED 8 8 8 0%
17.04 BANDED 8 8 8 0%
18.01 BANDED 8 8 1/4 8 1/4 3%
18.02 BANDED 8 8 1/4 8 1/4 3%
18.03 BANDED 8 8 1/8 8 1/8 2%
18.04 BANDED 8 8 8 0%
33.01 BANDED 2 2 2 0%
33.02 BANDED 2 2 1/8 2 1/8 6%
33.03 BANDED 2 2 1/8 2 1/8 6%
33.04 BANDED 2 2 2 0%
34.01 BANDED 2 1 3/4 1 3/4 -13%
34.02 BANDED 2 2 2 0%
34.03 BANDED 2 2 2 0%
34.04 BANDED 2 2 2 0%
22.01 BANDED 8 3/4 8 7/8 8 7/8 1%
22.02 BANDED 8 3/4 8 3/4 8 3/4 0%
35.01 BANDED 7 6 3/4 6 3/4 -4%
35.02 BANDED 7 7 7 0%
36.01 BANDED 7 1/8 7 1/2 7 1/2 5%
36.02 BANDED 7 1/8 7 1/4 7 1/4 2%
37.01 BANDED 7 1/8 7 7 -2%
37.02 BANDED 7 1/8 7 1/4 7 1/4 2%
37.03 BANDED 7 1/8 7 1/4 7 1/4 2%
38.01 BANDED 7 1/8 7 3/8 7 3/8 4%
38.02 BANDED 7 1/8 7 7 -2%
Post Tension Stressing Log
PAGE 8 OF 8
PROJECT NAME: Spring St Mixed Use PROJECT NO.: 04865-03
DATE: 6/1/2022 LOCATION: Level 10 Pour 10B
STRESSED BY: Tendon Systems/Anasteel RAM NO.:
POUR #: Level 10 Pour 10B GAUGE NO.:
VERIFIED BY: Palencia Charles JACKING FORCE: 33 KIPS
SPECIAL REMARKS:

TENDON TENDON GAUGE PRESSURE CALC. MEASURED ELONGATION DEVIATION


NO. TYPE JACKING LIFTOFF ELONG. (∆") END 1 END 2 TOTAL (%)
38.03 BANDED 7 1/8 7 1/2 7 1/2 5%
38.04 BANDED 7 1/8 7 1/4 7 1/4 2%
39.01 BANDED 7 7 7 0%
39.02 BANDED 7 7 1/4 7 1/4 4%
39.03 BANDED 7 7 7 0%
39.04 BANDED 7 6 3/4 6 3/4 -4%

25.01 BANDED 2 3/8 2 1/2 2 1/2 5%


25.02 BANDED 2 3/8 2 1/2 2 1/2 5%
25.03 BANDED 2 3/8 2 1/4 2 1/4 -5%

28.01 BANDED 2 7/8 2 3/4 2 3/4 -4%


28.02 BANDED 2 7/8 2 3/8 2 3/8 -17%
28.03 BANDED 2 7/8 2 7/8 2 7/8 0%
29.01 BANDED 2 7/8 2 5/8 2 5/8 -9%
29.02 BANDED 2 7/8 2 7/8 2 7/8 0%

You might also like