Professional Documents
Culture Documents
Mapefloor FC 200 ME: High Build Epoxy Resin Floor Coating
Mapefloor FC 200 ME: High Build Epoxy Resin Floor Coating
flo 0 M
pe 20
a
M FC
High build epoxy resin
floor coating
[Ceramica]
oor ME APPLICATION PROCEDURE 1. Multi-layered smooth coating
Ma FC
The surface of concrete floors must be dry, recommend shot-blasting or rough
clean, sound and have no crumbling or grinding with a diamond disk) and remove
detached portions. dust with a vacuum cleaner.
• Apply Primer SN at a rate of 0.2 kg/m2 (if
Do not apply Mapefloor FC 200 ME on required).
dusty substrates.
• When the primer has hardened apply the
first coat of Mapefloor FC 200 ME by
Do not apply Mapefloor FC 200 ME on
straight trowel or roller.
substrates with oil or grease stains or stains
in general. • Apply finishing coat of Mapefloor FC 200 ME
with a straight steel trowel down to a
The compressive strength of the substrate feather edge and then backroll crosswise
concrete must be at least 25 N/mm² and its with a short-piled roller or apply the mix
tensile strength must be at least 1.5 N/mm². directly on the surface with a
medium-piled roller.
The strength of the substrate must also be
suitable for its final use and the types of 2. Multi-layered non-slip coating
load to which it will be subjected. • Prepare the substrate as specified (we
recommend shot-blasting or rough
The surface of the floor must be prepared grinding with a diamond disk) and remove
with a suitable mechanical process (e.g. dust with a vacuum cleaner.
shot-blasting or grinding with a diamond • Apply Primer SN at a rate of 0.2 kg/m2 (if
disk) to remove all traces of dirt and cement
required).
laitance and crumbling or detached
• When the primer has hardened pour
portions, and to make the surface slightly
rough and absorbent. Before applying the Mapefloor FC 200 ME onto the floor and
coating, remove dust from the surface with spread it out evenly with a straight trowel
a vacuum cleaner. or roller.
• Fully broadcast with Quartz 0.5. If a higher
Any cracks must be repaired by filling them degree of non-slip finish is required, sand
with Eporip, while any deteriorated areas of with a larger particle size may be used. In
the concrete must be repaired with such cases the consumption rate of the
Adesilex PG2 TG. next coat will be higher.
• When the first coat of Mapefloor FC 200 ME
PRIMING has hardened remove any excess sand
Application of the primer and remove the last grains of sand
Priming is not normally required provided with an industrial-grade vacuum cleaner.
the substrate is sound and good quality • Apply the finishing coat of Mapefloor FC
non-porous concrete, if otherwise, it should
200 ME with a straight steel trowel down to
be primed with Primer SN.
a feather edge then backroll crosswise with
a short-piled roller, or apply the mix directly
Apply an even coat of neat Primer SN on
the substrate after it has been prepared as on the surface with a medium-piled roller.
specified with a straight trowel or roller. Make sure the roller strokes criss-cross to
get a better finish.
Preparation of the product
Mix component A thoroughly and add the CONSUMPTION
contents of component B in a clean container. 1. Multi-layered smooth coating.
Primer: (if required)
Power mix at low speed to prevent Primer SN (A+B): 0.15-0.20 kg/m²
entraining air into the mix (300-400 revs/min) (depending on the substrate condition).
for at least 2 minutes until the mix is
completely blended and the color is 1st coat:
uniform. Scrape the sides of the mixing Mapefloor FC 200 ME (A+B ): 0.30 kg/m²
container and remix.
Finishing coat:
Do not mix the product for too long to
Mapefloor FC 200 ME (A+B): 0.30 kg/m²
prevent entraining too much air into the mix.
Apply the mix within the pot life indicated in
the table (refers to a temperature of +25°C). 2. Multi-layered non-slip coating.
Higher surrounding temperatures will reduce Primer: (if required)
the pot life of the mix, while lower tempera- Primer SN (A+B): 0.15-0.20 kg/m²
tures will increase its pot life. (depending on the substrate condition).
PRODUCT IDENTITY
Component A Component B
oor ME literature is accurate and correct, we have The contents of this Technical Data Sheet
efl200
no control over the circumstances in which (“TDS”) may be copied into other project-
p
Ma FC
our product is used. It is therefore important related documents, but the resulting
that installers satisfy themselves that the document shall not supplement or
product and conditions are suitable for the replace requirements per the TDS in force
envisaged application. No warranty can be at the time of the MAPEI product installa-
given or responsibility accepted other than, tion. The most up-to-date TDS can be
that the product supplied by us will meet our downloaded from our website
written specification. The installer should www.mapei.com.
ensure that our latest product data and
safety information sheets have been consult- ANY ALTERATIONS TO THE WORDING
ed prior to use. OR REQUIREMENTS CONTAINED OR
DERIVED FROM THIS TDS EXCLUDES
Please refer to the current version of the THE RESPONSIBILITY OF MAPEI.
Technical Data Sheet, available from our
website www.mapei.com
All relevant references
for the product are available
upon request and from
www.mapei.com