R

R OPTEVA 522 LOBBY CASH DISPENSER


FRONT LOAD
5 HIGH WITH 40mm (1916") CEN III OR CEN IV SAFE
L879

CALL 1-800-999-3600

CONSULT WITH DIEBOLD INSTALLATION/SERVICE


BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
TP-821298-001.
M ETRES

DEPTH
NCHES)

HEIGHT
504
(191316") 1195mm 182mm
A TOP FUNCTION KEY
LLI

(47") (714")
NI
N MI

120mm
ONS I

991mm
B RECEIPT PRINTER
THOUT BAR CODE SCANNER

(39") (434")
ONS I

C KEYBOARD)
M ENSI

960mm

FORM AT KEYPAD)
100mm

TH BAR CODE SCANNER

TH BAR CODE SCANNER


C KEYPAD (TOP ROW)
M ENSI

(3734") (4")
DI

947mm 25mm
(

D
)
)

HEADPHONE JACK (ADA)


DI

33 4"
32"
813

(3712") (1")

)
844

3458"

NUM ERI
1

880
(

(
802mm 15mm
E ADVANCED FUNCTION DISPENSER

(
7 7
LARGE- (31 16") (16")

ALPHA-
1076mm 115mm
WI

WI

WI
F HEADPHONE JACK (CSA)
(4238") (412")
(

(
991mm 135mm
G MOTORIZED CARD READER
(39") (514")
RD ANGLE
ON

991mm 80mm
H
PROJECTI

DIP CARD READER


472 (39") (318")
(18916")
759mm
-
THI

PLAN VIEW I BAR CODE SCANNER


(2978")

1296mm 234mm
J TOP OF MONITOR
(51") (914")

HEIGHT - FROM BOTTOM OF SAFE


DEPTH - FROM FRONT EDGE OF BEZEL

686

504 (27")
80 50
16 (191316") 16
(318") (11516")
)

5 5
138"

( 8") ( 8")
35

)
318"
472 269 158

80
(

9
(18 16") (10916") (614")

(
PAGE 1 OF 4

)
318"

J
80

)
)

23"
)

584
14"
356

3316"
(

)
80

12916"
A

(
(

319
AIR VENTS (

)
318"
80
(
B F

(
C G H
CE"
TERIA

)
THOUT NOTI

5878"

)
1496

318"
GN CRI

80

D
(
(
ONS AND DESI

I
SUBJECT TO CHANGE W I

E
OPTIONAL CONSUMER
BAR CODE SCANNER
M ENSI

(SEE "CAUTION LABEL")


ALL DI

)
35"
889
"

POWER CORD - LENGTH


2210mm (87") FROM SIDE
OF UNIT
546 REV.4
LE NO.177-

141 568
1 3
(5 2") 40 (22 8")
5
(1 8") 749
FI

(2912")
FRONT VIEW
SIDE VIEW
R

CONDUIT AND JUNCTION BOX POWER REQUIREMENTS


REQUIREMENTS THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
1 102mm (4") SQ. X 54mm (218") DP. JUNCTION BOX (ALL BY OWNERS E.C.). DIEBOLD TO CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
PROVIDE FLAT COVER WITH TAMPER SWITCH. SPECIFIED BELOW.

WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED 100-127 VAC (+6%,-10%) 50Hz (+/-1%) SINGLE PHASE
TO CASH DISPENSER, OWNERS E.C. TO RUN 19mm 3 100-127 VAC (+6%,-10%) 60Hz (+/-1%) SINGLE PHASE
2 1
(4") METAL CONDUIT FROM 102mm
200-240 VAC (+/-10%) 50Hz (+/-1%) SINGLE PHASE
(4") SQ. X 54mm (2 8") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY.
200-240 VAC (+/-10%) 60Hz (+/-1%) SINGLE PHASE

OWNERS E.C. TO RUN 19mm 3


(4") LIQUID TIGHT FLEX METAL CONDUIT OR 19mm 3
(4") RIGID POWER TO THE CASH DISPENSER IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED
3 CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT
BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
3
19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ. BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
X 54mm (218") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF SIDE
4 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES
CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY 200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES
(ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS). THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN
SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
M ETRES

5 CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")


NCHES)

FROM SIDE OF UNIT.


POWER USAGE

MACHINE STATUS 1
LLI

NOTE: IDLE (NO TRANSACTION) 150 WATTS


NI
N MI

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING TRANSACTION (DISPENSE
230 WATTS
ONS I

PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). IN PROGRESS)


LOCATE IN AN EASILY ACCESSIBLE AREA.
ONS I

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONFIGURATION
M ENSI

CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER,
CONDUIT FOR EXISTING CONSTRUCTION.
1
RECEIPT PRINTER, AND 5 CASSETTE DISPENSER.
M ENSI

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.
DI
(

HEAT OUTPUT CONFIGURATION


DI

785 BTU/HR DISPENSING


1
512 BTU/HR IDLE

OPERATING ENVIRONMENT
SAFE LOCATION 10º C TO 40º C (50 F TO 104º F)
RELATIVE HUMIDITY ( NON-CONDENSING )
20 TO 80% AT 32º C (90º F),
20 TO 55% AT 40º C (104º F)

WEIGHT OF UNIT
CEN III - 582kg (1,284 LBS.)
CEN IV - 612kg (1,350 LBS.)

SIGNAL CABLE RUN CONSTRAINTS


RD ANGLE
ON

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN
WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
PROJECTI

SEPARATION FROM OTHER CABLES


CAUTION LABEL
TYPE OF ELECTRICAL RUN BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
THI

FLUORESCENT, NEON OR INCANDESCENT


127mm (5") 127mm (5") 127mm (5")
LIGHTING FIXTURES

UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT 127mm (5") 305mm (12") 610mm (2'-0")

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT


64mm (212") 152mm (6") 305mm (12")
WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT

POWER LINES IN GROUNDED CONDUIT WITH SIGNAL


CABLES IN GROUNDED CONDUIT 30mm (1316") 76mm (3") 152mm (6")

SIGNAL CABLE INSTALLATION CONSTRAINTS


RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND
LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT
WITHSTAND AS MUCH STRAIN IN INSTALLATION.

82 82 55 80
)
118"

(314") (314") (2316") (318")


28

)
138"
(

35
338 159 264
(1338")

(
(614") (1038")
PAGE 2 OF 4

)
1916"
)

40
202
8"

AIR VENTS
(

)
318"

318"
80

80
)
12916"
(

(
319

)
1

14"
356
AIR VENTS
)

(
10"
254
(

2
CE"
TERIA

)
318"

4
THOUT NOTI

80
)
1916"
GN CRI

)
318"
(
40

80

4
(
ONS AND DESI

(
SUBJECT TO CHANGE W I

AIR VENTS
M ENSI

1
ALL DI
"

5
546 REV.4

3
LE NO.177-

REAR VIEW SIDE VIEW


FI
R
R OPTEVA 522 LOBBY CASH DISPENSER
FRONT LOAD
5 HIGH WITH 40mm (1916") CEN III OR CEN IV SAFE
CALL 1-800-999-3600

682 682
13 13
) (26 16") (26 16")

)
4"
20

89 504 SAFE 89 89 504 SAFE 89

4"
20
3
(

1 13 1 1 13 1

3
(3 2") (19 16") (3 2") (3 2") (19 16") (3 2")

(
M ETRES

)
NCHES)

4"

4"
20

20
3

3
(

(
)

)
1978"

1978"
51 51

)
24"
505

505
610

)
)

27"
LLI

688
(2") (2")
24"
610
NI

(
)
(

(
27"
N MI

(
688
(
ONS I

(
ONS I
M ENSI

)
152

152
6"

6"
(

(
M ENSI
DI
(
DI

)
3434"

)
883

311116"
805
(

)
(

56316"

)
1428

53316"
1350
(

(
RD ANGLE
ON
PROJECTI

450 504 SAFE 310


(171116") (191316") (12316")
THI

1264
(4934")

PLAN VIEW
( MINIMUM SERVICE AREA ) 450 504 SAFE 310
(171116") (191316") (12316")

1264
(4934")

PLAN VIEW
( RECOMMENDED SERVICE AREA )
PAGE 3 OF 4

NOTE:
SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO
IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE
TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS.

20
3
( 4")
550 650 250 588
(2158") (25916") (978") (2318") RECOMMENDED SERVICE AREA
)
102

4"
(

MINIMUM SERVICE AREA


CE"
TERIA

ALL ELECTRICAL AND DATA CABLES


THOUT NOTI
GN CRI

MUST ENTER UNIT IN THIS AREA


1")
25

(
ONS AND DESI
SUBJECT TO CHANGE W I

ABLE
M ENSI

VARI
ALL DI

)
1475

58"
(
"
546 REV.4
LE NO.177-

HEIGHT OF SPACE IN FRONT OF TERMINAL SHOULD ALLOW A


PERSON TO STAND AND SERVICE THE TERMINAL

SIDE VIEW
FI

( MINIMUM/RECOMMENDED SERVICE AREA )


R

103 298 103


NOTES:
(4116") (1134") (4116")
FOR ADDED SECURITY:
IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH

)
41316"
ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR

123
YOUR INSTALLATION.

(
ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS:
IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS
3
1 1 WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (4") ANCHOR BOLT THAT
IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm

)
191116"
(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.

500
ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES.
)
2034"

(
527
M ETRES
NCHES)

)
LLI

1916"
2
NI

40
N MI
ONS I

(
CABLE ENTRY HOLE

)
ONS I

91316"
SEE NOTE

250
M ENSI

1 1
M ENSI

)
)

(
512"
31516"

140
100
DI

(
(
DI

396 108
(15916") (414")

CABLE ENTRY
ANCHORING HOLES SNAP-OFF DETECTOR
9 ELECTRICAL AND DATA CABLING ENTERS THE CASH DISPENSER
2. (1) 65mm (2
16") RECESS DIAMETER
1. (4) 45mm (134") RECESS DIAMETER 11
THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.
18mm ( 16") RECESS DEPTH CABLES ENTERING THE CASH DISPENSER PASS THROUGH THE
11
18mm ( 16") RECESS DEPTH 7
22mm (8") THROUGH-HOLE-DIAMETER POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL
25.4mm (1") THROUGH-HOLE-DIAMETER OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLES ENTER
RD ANGLE

FROM THE SIDE OF THE UNIT. THE CABLE ENTRY OPENING IS ON


ON

THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE
PLAN VIEW-SAFE FLOOR
PROJECTI

CASH DISPENSER.

1
29mm (1 8") DIA. HOLE FOR
THI

ALARM CABLES (SIDE ENTRY)

OPENING FOR POWER CORD


AND DATA CABLES (SIDE ENTRY)

POWER CABLE PLATE


PAGE 4 OF 4

702 905 905 341 221


5 5 5 7
(27 8") (35 8") (35 8") (13 16") (81116")
89 89
(312") (312")
)

361 504 SAFE 401 504 SAFE 401 504 SAFE

)
4"
20

4"
20
(14316") (191316") (151316") (191316") (151316") (191316")
3
(

3
(
CE"
TERIA
THOUT NOTI

)
GN CRI

1978"

450 310
505

(171116") 3
)

(12 16")
24"
610

27 16"
ONS AND DESI

688

51
(

1
SUBJECT TO CHANGE W I

(2")
(
)
M ENSI

152

6"
(
ALL DI
"

)
)

16"
3434"
883

805
11
(

31
(
546 REV.4
LE NO.177-

3074

(121116")

PLAN VIEW - ADJACENT UNITS


FI

(MINIMUM SERVICE AREA)

You might also like