Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

N A B C D E A B C D E A B C D E

E
8700 8700 8700 E
S
2800
4000 1400
3800
3100
700 1200
200
1500
4000
2500
1400
1400
3100
500 1200
200
2800
4000 1400
4000
3100
1700
200
D
1500 1200 2600 1400 1400 2600 2800 C
1400
900
TO STORM
DRAIN
1200 900 900 1400 1200 1400 1400
B
1a 1a
800

800

800
A.D. A.D.
VC
. P PE

A IAMN PI
C.B.
2" DDRAI
2200

2200

2200
SEPTIC
4" DIAM. PVC SOIL 2" DIAM. PVC WT WT 2" DIAM. PVC
TANK 02
DRAIN PIPE DRAIN PIPE
1400

1400

1400
STACK PIPE S.S. .
S.S. A.D
VC
. P OUT
A.D. WT . . IAM SP

1 C.O.
D.S.

4" DIAM. PVC


DRAIN PIPE
1 C.O. D.S.
1 D.S.

WT
D.S

3" DOWN
D
VC
. P OUT
IAM SP
D.S 3" DOWN
D

S.D. S.D. VC
.P VC
IAM W .P .
D.S
4" DIAM. PVC 3" DLBO IAM W
SEWER PIPE E 4" DLBO
2600

2600
4" DIAM. PVC E
VC VC
.P E .P E
DRAIN PIPE IAM PIP IAM PIP
2" DRAIN
W.C. W.C.
4" DVSTR S.D
. VC
D . P IPE
3900

3900

3900
F.D. F.D. IAM R P
4" DEWE
. C
C.O
C.O. C.O. S . PV E
IAM PIP
LAV. LAV.
.
4" DRAIN
A.D .
K.S. K.S. F.D .
W.C D VC
V. . P PE
C.O.
LA IAMN PI
TO STORM D.S
.
D.S
. 2" DDRAI
DRAIN 4" DIAM. PVC
1300

1300
SEWER PIPE VC
.P E
IAM PIP
4" DRAIN

1a
D . .
C.O A.D

2 2 2
. .
S.S . D.S C C
C.O
C . PV OUT . PV OUT
D.S. .S. IL PV E .S. IAM SP IAM SP
K
SO IAM. R PIP C D
3" DOWN 3" DOWN
. PV PE
D.S. D.S. .
VC D E S.P D D
.D. . P IPE 4" SEW IAM K PI

1400

1400
VC
1500

A.D. S M
IA K P . 4" DTAC . P PE
4" DTAC S.P .S.
IAM K PI
M .
OR W.C D S
ST IN S C VC 4" DTAC
TO DRA . PVPE . P OUT S
IAM PI
. .
F.D LAV C IAM SP
1
2800

2800

2800
4" DRAIN . PV IPE 3" DOWN
D IAM R P D

16600
.

16600
C.B 4" DEWE VC
13600

4" DIAM. PVC S .P E


IAM PIP
M
DRAIN PIPE OR D.S
.

4100
. . ST IN
4" DRAIN

1400

1400
A.D D.S TO DRA .
1300

A.D D
IC
PT 02
SE ANK
T
.
C C.B
. PV IPE
3 3 3 2 S.S
.
C.O
.
IAM R P
4" DEWE D.S
.
.S.
3500

D.S. D.S. D.S.


S D
F.D. S.D. .
K.S
1300

1300

1300
C.B. .
LAV. C.O S.P
.
.
. A.D
S.D .B. M
W.C. . . .
S.P D.S
C OR
W.C ST IN
. TO DRA

2700
C.O
. A.D
. .
A.D. S.P. S.P. S.P. S.P. C.O. F.D LAV
D.S. D.S.
A.D.
1400

1400

1400
4" DIAM. PVC IC
C.O. PT 01
SE ANK
SEWER PIPE T
4700

4700

4700
.
C.B

4" DIAM. PVC

3400
DRAIN PIPE

4
M
OR
ST IN
2500

TO DRA
2000

2000

4800

2000
.
2" DIAM. PVC . C.O
A.D
1100

DRAIN PIPE

4 4 D.S.
4 D.S.

1400

1400
C.B. A.D. A.D.

C.B.
3000

3000
SEPTIC
1600

1600
TANK 01

TO STORM

4a DRAIN
4a
TO STORM
DRAIN

1 BASEMENT FLOOR PLUMBING LAYOUT 2 FIRST FLOOR PLUMBING LAYOUT 3 SECOND FLOOR PLUMBING LAYOUT 4 plumbing isometry
SCALE SCALE SCALE SCALE
P 2 1 : 100 m. P 2 1 : 100 m. P 2 1 : 100 m. P 2 1 : 100 m.

2050
400 mm.
CLEANOUT COVER 3200 150 700 150 900 150
500 mm.
AD AREA DRAIN LS LAUNDRY SINK POURED CONCRETE RAD WALL
150 700 150 700 150 1200 150 150 mm.
10 mm. DIAMETER CO P TATION FOR
410 mm. 10 mm. DIAMETER PLAN REBARS SPACED AT
CLEANOUT COVER PLAN REBARS SPACED AT
12 mm. DIAM.
VERT. BARS
200 mm. B.W. O.C. SEPTIC TANK DI ENSIONS
CLEANOUT COVER 300 mm. 200 mm. B.W. O.C.

150
CB CATCH BASIN SD SHOWER DRAIN SPACED @

150
135 EGREES ELBOW
135 EGREES ELBOW 600MM O.C. SEPTIC TANK 01
DOWNSPOUT 10 mm. DIAM.

450
SINGLE FAMILY DWELLING
PVC PIPE HOR. BARS

350
INLET
CO CLEAN OUT SHO. SHOWER CONCRETE SLAB SPACED @
600MM O.C. REQUIRED SAY :
FINISHED FL. LN. ONE ( 1 ) UNIT = 750 GALLONS

1700
1400
100 mm.

500
100 mm. 3- 12 mm. DIAM. 100 mm.
12 mm. DIAMETER NOTE : ONE ( 1 ) CUBIC METER = 263.97 GALLONS

1500
1200
100 mm. LONGITUDINAL DIAM. PVC

500
SV SHOWER VALVE FINISHED FL. LINE DIAM. PVC DIAM. PVC
CV CHECK VALVE LIFTING HANDLE DIAM. PVC
OUTLET PIPE
INLET PIPE BARS OUTLET PIPE INLET PIPE
500 mm. DIMENSION OF SEPTIC TANK

410 mm.
300 mm.

450
= 1.20 m. (W) x 2.60 m. (L) x 1.50 m. (D)
SP SOIL PIPE PVC PIPE

350
DS DOWNSPOUT AT WALL
10 mm. DIAM.
= 4.680 CUBIC METER

150
REBARS SPACED
WYE

150
@ 200 mm. O.C. = 4.680 CU. M. x 263. 97 GALLONS
SS SERVICE SINK AT GRADE WYE 150 mm. DIAMETER
12 mm. DIAMETER 500 mm. x 500 mm.
F FAUCET N.R.C.P. OUTLET
12 mm. DIAMETER 500 mm. x 500 mm. LIFTING HANDLE MANHOLE = 1235.380 GALLONS BUT NOT LESS THAN 750 GALLONS
LIFTING HANDLE MANHOLE WALL FOOTING 10 mm. DIAMETER THEREFORE ADOPT :
SSP SOIL STACK PIPE PLAN CHB PLAN DETAIL 12 mm. DIAMETER
LIFTING HANDLE
BARS SPACED AT
150 mm. B.W. O.C.
FD FLOOR DRAIN 10 mm. DIAMETER SEPTIC TANK = 1.20m (W) x 2.60m (L) x 1.50m (D)
CLEAN OUT DETAILS

100
SECTION
6 500 mm. 12 mm. DIAMETER
LIFTING HANDLE
BARS SPACED AT
150 mm. B.W. O.C.
410 mm.

100
VSTR VENT STACK THRU ROOF P 2 SCALE 1: 25 m SECTION 10 mm.

300
DIAMETER AIR SPACE AIR SPACE
FV FLOAT VALVE 300 mm. 12 mm. DIAMETER REBARS 100 mm. DIAM.
SEPTIC TANK 02
10 mm. SINGLE FAMILY DWELLING
PVC INLET PIPE

300
100 mm. THK. LIFTING HANDLE DIAMETER AIR SPACE AIR SPACE AIR SPACE
WC WATER CLOSET C.H.B W/ 10 mm.
REBARS 100 mm. DIAM.
REQUIRED SAY :
GV GATE VALVE I E LAM
DIAM. REBARS 10 mm. DIAMETER
PVC INLET PIPE 100 mm. DIAM.
PVC OUTLET PIPE ONE ( 1 ) UNIT = 750 GALLONS
BARS B.W. NOTE : ONE ( 1 ) CUBIC METER = 263.97 GALLONS
WT WATER TANK I E SLEEVE
100 mm. DIAM.
PVC OUTLET PIPE 150 mm. THICK
LEACHING DIGESTIVE
KS KITCHEN SINK

2400
CHB WALL WITH DIMENSION OF SEPTIC TANK
CHAMBER CHAMBER

1800

2800
I E AN E PLAIN CEMENT

2100
150 mm. THICK
AN O BOLT
DOWNSPOUT

2200
WP WATER PUMP LEACHING LEACHING DIGESTIVE PLASTER FINISH = 1.40 m. (W) x 1.60 m. (L) x 2.10 m. (D)

1500
CHB WALL WITH
INLET PLAIN CEMENT CHAMBER CHAMBER CHAMBER ON INSIDE WALL
= 4.704 CUBIC METER
LAV. LAVATORY V VENT I E
PLASTER FINISH
500 mm.

S A B A E
ON INSIDE WALL = 4.704 CU. M. x 263. 97 GALLONS
415 mm.

V VENT STA = 1241.715 GALLONS BUT NOT LESS THAN 750 GALLONS
WATER LINE I E LAM
12 mm. DIAM.
VERT. BARS
12 mm. DIAM.
VERT. BARS THEREFORE ADOPT :
SPACED AT
100

SPACED AT
150 mm. DIAMETER 600 mm. O.C. 600 mm. O.C. SEPTIC TANK = 1.40m (W) x 1.60m (L) x 2.10m (D)

100
SEWER LINE

200

100
I E SLEEVE

200
LEAN O T N.R.C.P. OUTLET
3 - 12 mm. DIAMETER FOOTING 10 mm. DIAMETER REFERENCE: NATIONAL PLUMBING CODE OF THE PHILIPPINES.
3 - 12 mm. DIAMETER FOOTING
V SE E I E SECTION 3 - 12 mm. DIAMETER FOOTING BARS SPACED EQUALLY O.C. BARS AT 200 mm. BARS SPACED EQUALLY O.C.
10 mm. DIAMETER
APPENDIX B. PRIVATE SEWAGE DISPOSAL SYSTEM.
STORM LINE BARS SPACED EQUALLY O.C. B.W. WITH 10 mm. DIAM. REBARS
SP. @ 200 mm. O.C.B.W.
B.W. O.C.
SEPTIC TANK 01 WITH 10 mm. DIAM. REBARS
BARS AT 200 mm.
B.W. O.C. SEPTIC TANK 02 B.2 CAPACITY OF SEPTIC TANK
SP. @ 200 mm. O.C.B.W.

5 legends 7 SOIL STACK DETAILS 8 CATCH BASIN DETAILS 9 SEPTIC TANK DETAILS
SCALE SCALE SCALE
P 2 SCALE NTS P 2 NTS P 2 1: 20 m P 2 AS SHOWN

DESIGNER DESIGNER DRAWN BY CHECKED BY ARCHITECT MASTER PLUMBER REVISION DATE DESCRIPTION PROJECT TITLE SHEET CONTENTS OWNER SHEET NO.
FLAM ARCH. AST PRC NO. 00 22 333

AS TOLEAN + ARCHITECTS DATE : AUGUST 25, 2021 DATE : VALIDITY JULY 12, 2023
O OSE T O STO E S O SES OMEL . OLOMA P
PTR NO. 6868307 MELVIN ALIMBA
ARCHITECTURE BUILDERS PLANNING THESE DRAWINGS AND ITS SPECIFICATION INTENTS ARE INSTRUMENTS OF
PROFESSIONAL SERVICE PURSUANT TO RA 9266 (ARCHITECTURE ACT OF 2004). SECTION 33 - ISSUED ON JANUARY 11, 2021
ESI EN E IT BASEMENT
AS SHOWN MA BEL L. OLOMA 2 2
JA 146 UPPER COGCOGA, KM. 3 PICO, LA TRINIDAD, BENGUET OWNERSHIP OF PLANS, SPECIFICATIONS & OTHER CONTRACT DOCUMENTS, RA 8293 (COPYRIGHT
TRAININGS LAW) AND P.D. 49 THEY ARE THE INTELLECTUAL PROPERTY AND DOCUMENTS OF AS ISSUED AT LA TRINIDAD, BENGUET PRC NO. 0004643
E-MAIL ADD.: ar_albhees@yahoo.com BOSH (SO1)
TOLEAN + ARCHITECTS, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS ALVEZ S. TOLEAN, uap LOCATION ADDRESS PROJECT NO.
EXECUTED OR NOT, IT SHALL NOT BE USE OR REPRODUCE IN WHOLE OR IN PART UAP NO. 17662 PTR NO. 4866381
MOBILE NO.S COSH (SO2) FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDINGS,
LCM (SO3) WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT PROPER PERMISSION OR IAPOA NO. 17662 295419 090720 DATE ISSUED. 01/04/2021
SMART # 0921 627 2449 / B.B.S. WRITTEN CONSENT FROM THE ARCHITECT. LUBAS, LA TRINIDAD, BENGUET BALILI, LA TRINIDAD, BENGUET
GLOBE # 0927 4451 451 FIRST AIDER JUNE 30, 2021 ISSUED AT BAGUIO, CITY