Interactive Schematic: This Document Is Best Viewed at A Screen Resolution of 1024 X 768

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Switch Switch Switch Switch Circuit Breaker Pump
Variability
FUNCTION KEYS or Motor

Click here to view the


Spring
Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner (Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB
MOTORS
AB
Single Acting Double Acting
Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
ACCUMULATORS Unidirectional Bidirectional Control Line Restriction
Valves (Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.

PILOT CONTROL
Line Restriction 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR3630-01
July 2017

336F and 340F Excavator


Hydraulic System - Attachment
336F: 340F:
TZA1-UP RBD1-UP
RKB1-UP YBF1-UP
RBC1-UP SGH1-UP
YFD1-UP EAR1-UP
TJE1-UP
DKF1-UP
WCF1-UP
ZBJ1-UP
LCL1-UP
NBL1-UP
SSN1-UP
KCS1-UP
NBS1-UP
KFT1-UP
DSW1-UP
LJY1-UP
WTZ1-UP

Medium Pressure - Electric Control

© 2017 Caterpillar CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, and the POWER EDGE trade dress as well as
All Rights Reserved corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Schematic Machine
Description
Location Location
Accumulator Gp - Hydraulic (Charged) B-4 1
Control Gp - Joystick (LH) E-3 2
Control Gp - Joystick (RH) E-2 3
Filter and Valve Gp - Pilot (Hydraulic Oil) B-4 4
Filter Gp - Oil (Hydraulic Return) A-4 5
Filter Gp - Oil (Hydraulic, Case Drain) A-4 6
Manifold Gp - Control (Pilot Oil Supply) B-4 7
Motor Gp - Swing F-6 8
Motor Gp - Travel (LH) F-5 9
Motor Gp - Travel (RH) F-4 10
Pump Gp - Main Hydraulic B-2 11
Sensor Gp - Pressure (Boom Cylinder Head) F-7 12
Sensor Gp - Pressure (Boom Down Control) D-3 13
Sensor Gp - Pressure (Drive) A-7 14
Sensor Gp - Pressure (Idler) A-6 15
Sensor Gp - Pressure (Implement) D-2 34
Sensor Gp - Pressure (NFC 1) D-8 16
Sensor Gp - Pressure (NFC 2) D-5 17
Sensor Gp - Pressure (Swing Control) D-2 18
Sensor Gp - Pressure (Travel Left) F-3 35
Sensor Gp - Pressure (Travel Right) F-3 36
Swivel Gp E-5 19
Valve Gp - Check B-8 20
Valve Gp - Check (Return) D-5 21
Valve Gp - Load Control (Boom Drift Reduction) B-8 22
Valve Gp - Load Control (Stick Drift Reduction) D-5 23
Valve Gp - Main Control A-6 24
Valve Gp - Pilot (Travel) (Shuttle) F-3 25
Valve Gp - Pressure Reducing (Boom Priority) C-3 26
Valve Gp - Shuttle D-2 27
Valve Gp - Swing Cushion F-6 28
Valve Gp - Travel Counterbalance (LH) E-5 29
Valve Gp - Travel Counterbalance (RH) E-4 30
Attachments: Medium Pressure - Electric Control
Pump Gp - Medium Pressure B-3 31
Valve Gp - Control (Medium Pressure, Pump Relief) E-8 32
Valve Gp - Solenoid (AUX) D-4 33

Note: Check Part Number In The Part Manual For Your Specific Machine.
TAP LOCATION

Tap Schematic
Description
Number Location
AA Idler Pump Pressure B-3
BB Case Drain Pressure B-3
CC Drive Pump Pressure A-3
DD ESP Drive Solenoid Pressure A-2
EE ESP Idler Solenoid Pressure B-2
FF Boom Regeneration Pressure B-8
GG ATT Stem 3 Extend EPRV Pressure D-4
HH ATT Stem 3 Retract EPRV Pressure D-4
II Medium Pressure E-7
PG Pilot Pump Pressure A-4
SOS Oil Sampling Port A-4
8 7 6 5 4 3 2 1
(8) MOTOR GP (9) MOTOR GP
SWING TRAVEL (LH)
SWING MOTOR 334-9973 TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT)
SWG 355-5668
PRKG BK (25) VALVE GP
BUCKET CYLINDER STICK CYLINDER BOOM CYLINDER CONTROL PG TP PILOT (TRAVEL) (SHUTTLE)
369-8502
TT
SWG DR (10) MOTOR GP
MOTOR TRAVEL(L) TRAVEL(R)
DRAIN TRAVEL (RH)
MU 355-5668
F MU F
(12) SENSOR GP
PRESSURE AG BG
L5 R5 L6 SP2 (BOOM CYLINDER HEAD) Pp3 Pp3
338-6971
T1 T1
A1 DR B1
R3 BP2 (FWD) (BKWD) (BKWD) (FWD)
T2 T2 T5 T1 T3 T6 T4
T2
T2 pR1f pL1f pL2b pR2b
NOTE A NOTE A (36) SENSOR GP
PRESSURE (RIGHT TRAVEL)
AG BG BG AG (35) SENSOR GP 454-5075
(28) VALVE GP
SWING CUSHION PRESSURE
(EXT) (RET) 158-9085 (LEFT TRAVEL)
Pa1 Pb1 (R) A B (L) PD-Dr
454-5075 5 6 3 2
(32) VALVE GP 4 1
L4 R4
CONTROL (MEDIUM PRESSURE,
A B B A
PUMP RELIEF) (RET) B1 4 1
310-0165 (29) VALVE GP
E (30) VALVE GP 5 6 3 2 E
TRAVEL COUNTERBALANCE (LH) TRAVEL COUNTERBALANCE (RH) PD-Pi
(EXT) A1 322-8714 322-8714 (3) CONTROL GP
(2) CONTROL GP
(BKWD) (FWD) (BKWD) (FWD) JOYSTICK (RH)
JOYSTICK (LH) JLP JRP
L1 R1 L2 R2 335-0511 335-0510
2 SPEED JLT JRT
P TRAVEL
PLS M.P.V-P STICK SWING BUCKET BOOM
(19) SWIVEL GP CONTROL
SWG 234-4440
DRAIN
PPS MOTOR
T1 FILTER
M.P.V-T R.C.V-D DRAIN
II
(21) VALVE GP (OUT) (IN) (R) (L) (OPEN) (CLOSE) (DOWN) (UP)
CHECK (RETURN) C JL1 JL3 JL2 JL4 JR2 JR4 JR1 JR3
455-3961 M.P.V-T

(17) SENSOR GP
PRESSURE (NFC 2)
(16) SENSOR GP
338-6970
PRESSURE (NFC 1) B (27) VALVE GP
338-6970 NFC1 NFC2 SHUTTLE
323-7560
E
D (23) VALVE GP GG A1 A2 A3 A4 A5 A6 A7 A8 D
LOAD CONTROL HH
(STICK DRIFT REDUCTION) Pa1 Pb1
A 335-0200
MU
T (33) VALVE GP
SDr A2 B2 A1 B1 SOLENOID (AUX) B1 C1 B2 B3 C2 B4 C3 B5 B6 B7 C4 B8
L6 SPi (EXT) (RET) 259-7430
56 55 pL5f pR4b
pL4b

SP2 P
R6 (13) SENSOR GP (18) SENSOR GP
PRESSURE pBR pR5f pR6f
SP1 PRESSURE
T (BOOM DOWN CONTROL) (SWING CONTROL)
pL3b pR5b
454-5075 454-5075
ST6 ST SOL3-T
BPi pL3f (34) SENSOR GP
pL6f PRESSURE (IMPLEMENT)
(IN) pSR SPi
2 SPEED 454-5075
STICK(2) pR3f
TRAVEL (26) VALVE GP NOTE A pSR
pR6f CONTROL PRESSURE REDUCING
(OUT) dST
(BOOM PRIORITY) pR3b
C L5 C
pST MF-P PD-Pi MF-TANK 352-7065 B
(OPEN) pL5b
R5
P A IDENT CONNECTOR
pR5f P2 Pi1 P-IN PSA2 DR1 PSA1 T-OUT2 DR2 pL6f
1 LEFT TRAVEL PRESS SW
(CLOSE)
pL5f pR5b 18 20 2 RIGHT TRAVEL PRESS SW
(OUT)
STICK(1) 17 3 IMPLEMENT PRESS SW
BUCKET T
13 BOOM REGEN REPRV
(IN)
pL5b PRV-T 17 SWING BREAK SOL
(1) ACCUMULATOR GP 18 TRAVEL SPEED CHANGE SOL
L4 HYDRAULIC (CHARGED)
164-6981 19 STRAIGHT TRAVEL SOL
(R) 21 RDr
pL4b 352-6860 BC/AL REGULATION 20 HYD LOCK SOL
P1 AA 21 SWING PRIORITY VALVE
R4 PAC M2 A2
BRG 22 HEAVY LIFT SOL
FF 13 (L)
P2
pR4b DR3 DR4 Pi2 DR5 T-OUT1 DR6 51 ATT STEM 3 EXTEND EPRV
(UP) BB DrM
pL3b 38 53 ATT STEM 3 RETRACT EPRV
SWING (7) MANIFOLD GP SOL3-T
CONTROL (PILOT OIL SUPPLY) A3
(20) VALVE GP BDr LINE PATTERNS
CHECK pL3f
(UP) pBR
215-5037
PD-Dr EE
389-2477 M4 Pressure Line
B PRV-T SWG B
BT3 R3 PRKG BK Pilot / Load Sensing Pressure
CONTROL Q MAX Q MIN
BT Drain / Return Lines
(4) FILTER AND VALVE GP (31) PUMP GP
MF-P Dr (11) PUMP GP Component Group
PILOT (HYDRAULIC OIL) MEDIUM PRESSURE
BP1 L3 158-8987 MAIN HYDRAULIC
418-8372 CALLOUTS
M.P.V-P 377-4950
BP2 pR3b YY Taps (Pressure, Sampling, Sensor - by letter)
OUT IN Connectors (By letter)
BOOM(1) BOOM(2) DL DL D

Callout Number Component

BPi pR3f T (Machine Location from (52) VALVE GP - CONTROL Name


(DOWN) Component LocationsTable)
138-1234 Part Number

BDr R2 Q MAX Q MIN


SDr HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
pR2b
(22) VALVE GP (FWD) M3
HEAVY LIFT CIRCUIT

LOAD CONTROL TRAVEL(R) dR1b DD PILOT PUMP OUTPUT


DRIVE PUMP OUTPUT
(BOOM DRIFT REDUCTION) L2 PG SOS LEFT TRAVEL CIRCUIT
R1 SUPPLY LINE
323-7610 DRAIN STICK CYLINDER CONTROL CIRCUIT
pL2b pR1f RDr FILTER SWING CONTROL CIRCUIT
(BKWD) (FWD) 37 DRAIN / RETURN LINE
R.C.V-D M1 A1 SWING BRAKE CIRCUIT
TRAVEL(L) dR1b MF-TANK CC P1 IDLER PUMP OUTPUT
STR-TRAVEL TRAVEL SPEED CONTROL CIRCUIT
S3 S1 BUCKET CYLINDER CONTROL CIRCUIT
L1
A RIGHT TRAVEL CIRCUIT
BOOM CYLINDER CONTROL CIRCUIT
A
pL1f MEDIUM PRESSURE CONTROL CIRCUIT
(BKWD)
pST (6) FILTER GP THIS SCHEMATIC IS FOR THE 336F AND 340F EXCAVATOR HYDRAULIC SYSTEM
OIL (HYDRAULIC, CASE DRAIN) ATTACHMENT: MEDIUM PRESSURE - ELECTRIC CONTROL
dST 19 289-8194
PUMP-S1 PUMP-S2 MEDIA NUMBER: UENR3630-01
HPi
P1 SCHEMATIC PART NUMBER: 369-8520, CHANGE: 00, VERSION: HE
(24) VALVE GP HEAVY LIFT
Do not operate or work on this product unless you have
(15) SENSOR GP MAIN CONTROL
read and understood the instruction and warnings in the SCHEMATIC PART NUMBER: 497-9570, CHANGE: 00, VERSION: HE
(14) SENSOR GP (5) FILTER GP relevant Operation and Maintenance Manuals and
PRESSURE (DRIVE) PRESSURE (IDLER) P2 369-8542 (HEAVY LIFT) NOTE A: relevant service literature. Failure to follow the instruc- Components are shown installed on a fully operable machine with the key and engine off, with parking brake set.
OIL (HYDRAULIC RETURN) 319-4407 PRESSURE SWITCH FOR SERIAL NUMBERS 1 - 10000 tions or heed the warnings could result in injury or Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
338-6971 338-6971 369-8540 (STD) 188-4145 454-5075 PRESSURE SENSOR FOR SERIAL NUMBERS 10001 - UP death. Proper care is your responsibility. Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

8 7 6 5 4 3 2 1
CAB - FRONT VIEW
VIEW ALL CALLOUTS

3 13

27

18

25
34
36

35
MACHINE - TOP RIGHT VIEW
VIEW ALL CALLOUTS
II
GG
32

HH

33

28

12

19

9
8
29
5
30
10
MAIN CONTROL VALVE - FRONT VIEW
VIEW ALL CALLOUTS
17 21

24

FF
16

23 26

15
20

14

22

1 7
PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

11 CC AA BB EE 6

DD

31

SOS PG