Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

Instrument status list

Customer name Name of instrument MLS045 The number of pages 3 pages


NO project Function parameter
1. Operating Voltage DC12V。
Shutdown gate, standby power
2. Less than 4mA。
consumption
The tire has a circumference of 1.85 meters and two magnetic steels in one circle.
3. RPMometer LCD display, 36Hz = 63KM / H; when there is a RPM, the RPM signal lights begin
to flow.
4. Tachometer Liquid crystal display, 166 Hz vs. 10 x 1000 r/min.
Liquid crystal display, connected with fuel sensor, fuel block display, not connected
with no display.
0 block, e,
F, fuel
1 flash, oil 1 2 3 4 5
piece dispenser
pot flash pieces pieces pieces pieces pieces
5. Fuel gauge symbol
flashing
2 line
More 14
require 89-81 80-71 70-53 52-34 33-15
than 90 below
ment

Liquid crystal display, connected with water temperature sensor, water temperature
block long display, do not connect not display.
0 pieces 3 4 5
piece 1 pieces 2 pieces
pieces pieces flashes
6. Water temperature gauge
resistan 699-558 557- 193- 136- 125-
82Eur
ce(Ω Europe 194Eur 137Eur 126Eur 83Euro
ope
) ope ope ope pe

7. Undervoltage alarm No.


A. press the key briefly to switch between total (ODO) and subtotal (trip).

B. in the total (ODO) interface, long press the key for 8 seconds to switch between
metric system and English system. The default is metric system. After switching, it
can be saved even if the power is completely cut off.
C. in the trip interface, long press the key for 4 seconds to clear the subtotal.
8. Key Function
D. in the total (ODO) interface, long press the key for 4 seconds to release, enter the
clock setting, the hour position flashes, the second point does not flash, short
press the key plus 1, long press the key for 3 seconds to switch to the minute
position second flash, the second point does not flash, and then long press the
key for 3 seconds to save the exit or 10 seconds to save the exit automatically
without operation.
12 hour system, cold start am10:00, in the total (ODO) interface, long press the key for
4 seconds to release, enter the clock setting, the hour position flashes, the second
9. Clock adjustment point does not flash, short press the key plus 1, long press the key for 3 seconds to
switch to the minute position second flash, the second point does not flash, and then
long press the key for 3 seconds to save or 10 seconds to save automatically.
10. Backlight LCD backlight: white.
11. LCD screen The 6 point.
12. sensor

From the
cable side ①Red and black: RPM signal
②Brown Red: fault symbol
① ② ③ ③Black: electric door lock
④ ⑤ ⑥ ④Shallow orchid: turn right
13. ⑤Blue: high beam
⑦ ⑧ ⑨
⑥Orange: turn left
⑦Red: battery (normal, 12V positive)
Terminal DJ621-E2.8*0.5 ⑧Blue / White: fuel signal
Plastic
DJ7091A-2.8-21 white ⑨Green: negative
Parts

From the
cable side
Green / red: N file
N ① ②
Pink: 1st gear
③ ④ ⑤ Blue / red: 2 files
14.
Green / Black: 3 files
Terminal DJ621-E2.8*0.5 Yellow / red: 4 files
Plastic Yellow / white: 5 files
DJ7061A-2.8-21 white
Parts

Grey: 6th gear


Green and white: water temperature signal
15. 4 round head Brown: backlight control, 12V forward control,
When the backlight is on, the backlight brightness decreases
from 100% to 30%.

16.

From the
cable side

①Red / White: sensor positive


① ② ③
②Green: sensor negative
③Black / White: sensor signal

Terminal DJ621-E2.8*0.5
Plastic
DJ7031A-2.8-21
Parts
1 background parameter setting

1.1. Press and hold the key first, then open the switch lock, and enter the back door setting in 5S, which is divided into 6 interfaces

1.2. Interface 1: tire circumference setting


The 188 first digit of the vehicle RPM display shows 1, and the total cumulative display is c-1850. 1850 indicates that the default tire
circumference is 1850mm, with a flash of one thousand positions. Short press the key to modify, and if there is no operation for 5S, a flash
of one hundred positions will cycle to one position, (and then jump to a flash of one thousand positions). The perimeter can be set from
500-2600mm. Long press the key for 3 seconds to save and enter the magnetic steel number setting interface.

1.3. Interface 2: magnetic steel number setting


The 188 first digit of the vehicle RPM display shows 2, the total cumulative display C --- 02, 02 represents the number of magnetic steel, 1-
12 can be set, short press the key to modify. Press and hold the key for 3S to enter the RPM setting interface.

1.4. Interface 3: RPM setting interface


The 188 first digit of the vehicle RPM display shows 3, and the total cumulative display shows C --- 2. 2 indicates that the engine is
cylinder 2 Press the key briefly to switch cylinder 2 / 4. Press and hold the key for 3 seconds to enter the two-wire three wire fuel setting
interface. ,

1.5. Interface 4: two lines and three lines fuel setting (two lines and three lines can be set in the general item of upper computer)
The 188 first digit of the vehicle RPM display shows 4, the total cumulative display e ---- 2, 2 represents the second line oil meter, set as the
third line display e ---- 3, set as the second line display e ---- 2, short press the key to switch the third line / second line. Press and hold the
key for 3S to enter the cumulative reset interface.

1.6. Interface 5: metric and English settings (this point should be included in the general settings on the upper computer)
The 188 first digit of the vehicle RPM display shows 5, and the lower right corner shows km / h. short press km / h to switch to mph. Press
and hold the key for 3S to enter the mileage clearing interface. Default value km / h

1.7. Interface 6: cumulative reset


The 188 first digit of the vehicle RPM display shows 6 in 8 words. Press the key briefly to clear it. It can clear it for 200km at a time. You
can clear it three times (one time for entering the back door setting) and long press or power off to exit the back door setting.

You might also like