Tanktopper Series I, II & III: Tanktop Mounted Return Line Filters With Integrated Air Breather Max. 650 I/min - 10 Bar
Tanktopper Series I, II & III: Tanktop Mounted Return Line Filters With Integrated Air Breather Max. 650 I/min - 10 Bar
When an all-in-one RE
EN
G ING ®
solution matters VE R
F
TI TU
I
VA EA
NO F
IN TER
E
N
A FIL
Reduction of reservoir
accessories
L
The Tanktopper Series features
an integrated, 10 micron Abs. air
breather. Maximum pressure 10 bar.
Maximum flow 650 l/min. LEIF®
elements available. An all-in-one,
easy-to-mount filter range for more
compact tank design.
www.parker.com/hfde
Parker Hannifin
Hydraulic Filter Division Europe
61 FDHB500UK.
FDHB500UK/Tanktopper
Tanktopper Series I, II & III
Tanktop Mounted Return Line Filters
with Integrated Air Breather
Typical Applications
Parker Hannifin
Hydraulic Filter Division Europe
62 FDHB500UK.
FDHB500UK/Tanktopper
Specification
2
(1.06)
3
77 (3.03)
4
(0.59) D
33 (1.3)
0.2
3.2
15
11
Min 3.15)
M8
(0.59)
5
.80
15
R61
74±0.5 (2.91±0.02)
mm
Min.80mm
6
Mounting hole
(3.15)
13
12
Ø72.9
Max oil-level 0°-max.45°
7
(2.87)
Ø61
(2.40)
H
1 1 Cover
55 (2.16) 61 (2.40) 2 1 Magnet-set
)
G / 8(BSP 3 1 Cover-seal
1 8
O 22 10 4 1 Bridge (blue)
54° IS 5 1 LEIF® Element
6 1 Sleeve
7 1 Funnel-assembly
Pitch 90
8 1 Filter-housing
74 (2.91)
9 1 Housing-seal
Length H F D 10 1 Airguide
54° 11 1 Cover airbreather
ISO G 1/
228 8 169 160 G3/4 12 1 Breather-element
Indicator (BS 1 TPR1-40 (6.65) (6.30) (BSP)
P ) Ø9 (0.35) 13 1 Dipstick assembly
61 (2.40) Max. torque-load 269 260
filter-tank 8 Nm 2 TPR1-80 (10.60) (10.23) SAE 12
Dimensions in mm
Parker Hannifin
Hydraulic Filter Division Europe
63 FDHB500UK.
FDHB500UK/Tanktopper
Tanktopper Series I, II & III
Tanktop Mounted Return Line Filters
with Integrated Air Breather
Specification (cont.)
Tanktopper II (length 5, 6 and 7) 1
2
F Free element clearance 3
4
5
100 Second port optional
(D) 6
(3.94)
17
40 3.2 0.3 (0.67) (Port) D
(1.59)
7
G1 / 1 4 (BSP)
4xM8 111+0.5
0 8
Mounting hole G11/2 (BSP)
(Min. 100mm) SAE 20
(3.94) 9
Max oil level (H) SAE 24 14
Length H F
181 170
5 TPR2-120 (7.12) (6.70)
267 255 10
6 TPR2-200 (10.51) (10.03)
4x9 on pitch circle Ø145 400 380
Torque-load max. 8 Nm (5.70) 7 TPR 2-250 (15.75) (14.96)
ISO 228 G1/8 (BSP) Dimensions in mm
11
82 (Min. 100mm) 12
(3.23) (3.94)
105
(4.13)
* For filter with
air breather:
In order to keep the
13
Tanktopper II & III
minimum required
Ø40 distance under all Ref. No. Description
(1.57) Top view circumstances, it is 1 1 Hexagon socket bolt M8
recommended to 2 1 Air breather cap
171 (6.73) position the filter in
the middle of the 3 1 Air breather filter medium
4 1 Cover (assembly)
Tanktopper III (length 10 and 11) reservoir
5 1 Cover seal
6 1 Bridge
Free element clearance 7 1 Magnet set
8 1 Element
1 9 1 Sleeve
10 1 Filter house
(5.31)
135
2
11 1 Airguide
(D) 3 12 1 Tank gasket
Second port optional
13 1 Funnel
(1.73)
*
44
10
4x11 on pitch circle 185
ISO 228-G1/8 (BSP) Torque-load max. 15 Nm
110 (4.33) 110 (4.33)
11
130
(5.12)
Filter housing and element pressure drop based on 32cSt fluid viscosity and 0.87 density.
TPR40 Empty Housing (Length code 1) TPR80 Empty Housing (Length code 2)
Flow (US GPM) Flow (US GPM)
0 1 3 4 5 6 8 9 11 12 13 0 3 5 8 11 13 16 18 21 24
0.2 2.9 0.2 2.9
0.15 0.15
∆p (PSID)
∆p (PSID)
∆p (bar)
∆p (bar)
0.05 0.05
0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90
Flow (l/min) Flow (l/min)
0 1 3 4 5 6 8 9 11 12 13 0 3 5 8 11 13 16 18 21 24
1.4 20.3 1.4 20.3
∆p (PSID)
∆p (PSID)
∆p (bar)
∆p (bar)
0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90
Flow (l/min) Flow (l/min)
0 1 3 4 5 6 8 9 11 12 13 0 3 5 8 11 13 16 18 21 24
0.1 1.5 0.1 1.5
∆p (PSID)
∆p (PSID)
10C 10C
0.04 0.58 0.04 0.58
040W 040W
0.02 0.29 0.02 0.29
0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90
Flow (l/min) Flow (l/min)
0 5 11 16 21 26 31 37 42 0 5 11 16 21 26 31 37 42 47 53 58 64 69
0.2 2.9 0.2 2.9
0.15 0.15
∆p (PSID)
∆p (PSID)
∆p (bar)
∆p (bar)
0.05 0.05
0 0 0 0
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160 180 200 220 240 260
Flow (l/min) Flow (l/min)
Parker Hannifin
Hydraulic Filter Division Europe
65 FDHB500UK.
FDHB500UK/Tanktopper
Tanktopper Series II & III
Tanktop Mounted Return Line Filters
with Integrated Air Breather
Pressure Drop Curves - Tanktopper II (cont.)
Filter housing and element pressure drop based on 32cSt fluid viscosity and 0.87 density.
0 5 11 16 21 26 31 37 0 13 26 39 53 66 79
0.8 11.6 0.9 13.1
0.7 10.2 0.8 11.6
02Q
02Q 0.7 10.2
0.6 8.7
05Q 0.6 8.7
∆p (PSID)
∆p (PSID)
0.5 7.3 05Q
∆p (bar)
∆p (bar)
0.5 7.3
0.4 5.8
0.4 5.8
10Q 4.4 10Q
0.3
0.3 4.4
0.2 2.9 0.2 2.9
20Q
0.1 1.5 20Q 1.5
0.1
0 0 0 0
0 20 40 60 80 100 120 140 0 50 100 150 200 250 300
Flow (l/min) Flow (l/min)
0 13 26 39 53 66 79
0.8 11.6
0.7 10.2
0.6 8.7
∆p (PSID)
0.5 7.3
∆p (bar)
02Q 05Q
0.4 5.8
0.3 4.4
10Q
0.2 2.9
20Q
0.1 1.5
0 0
0 50 100 150 200 250 300
Flow (l/min)
Filter housing and element pressure drop based on 32cSt fluid viscosity and 0.87 density.
TPR III Empty Housing with G11/2” ports
(Length code 10 and 11)
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132 145 159 172 185 198 211 225
1 14.5
0.9
0.8 11.6
0.7
∆p (PSID)
0.6 8.7
∆p (bar)
0.5
0.4 5.8
0.3
0.2 2.9
0.1
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850
Flow (l/min)
TPR450 (Element length code 10) TPR650 (Element length code 11)
Flow (US GPM) Flow (US GPM)
0 26 53 79 106 132 159 185 0 26 53 79 106 132 159 185 211 238
1.2 17.4 1.2 17.4
02Q
1
02Q
14.5 1 14.5
∆p (PSID)
∆p (bar)
∆p (bar)
05Q 05Q
0.6 8.7 0.6 8.7
10Q 10Q
0.4 5.8 0.4 5.8
20Q
20Q
0.2 2.9 0.2 2.9
0 0 0 0
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700 800 900
Flow (l/min) Flow (l/min)
Parker Hannifin
Hydraulic Filter Division Europe
66 FDHB500UK.
FDHB500UK/Tanktopper
Tanktopper Series I, II & III
Tanktop Mounted Return Line Filters
with Integrated Air Breather
Ordering Information
Product configurator
Configurator example TPR filter
Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
TPR 2 05QL B S2 E G12 L
Box 7 Box 8
Filter connection Options
Ports Code Options Code
G3/4 (BSP) (TPR 1 Series) G12 Standard 1
SAE12 (TPR 1 Series) S12 Dipstick 6
G11/4 (BSP) (TPR 2 Series) G20 Aluminium funnel for TPR 1-80 J Highlights Key (Denotes part
2 x ISO 228-G11/4 (BSP) (TPR 2 Series) 2G20 Magnets for TPR 1 Series E number availability)
SAE 20 (TPR 2 Series) S20 Magnets + Dipstick for TPR 1 Series K 123 Item is standard
2 x SAE 20 (TPR 2 Series) 2S20 Magnets + Aluminium Funnel for TPR 80 Series L 123 Item is standard green option
SAE 24 (TPR 2 Series) S24 Magnets + Aluminium Funnel + Dipstick for TPR 80 Series M 123 Item is semi standard
2 x SAE 24 (TPR 2 Series) 2S24 Other combinations on request 123 Item is non standard
G11/2 (BSP) (TPR 2 and 3 Series) G24 Note: Tanktopper I Series are standard supplied with POM type funnel.
2 x G11/2 (BSP) (TPR 2 and 3 Series) 2G24 Aluminium funnel is recommended for heavy duty applications, sensitivity for
electrostatically charging or high fluid temperatures.
Tanktopper II and III Series are always supplied with metal funnel.
Parker Hannifin
Hydraulic Filter Division Europe
67 FDHB500UK.
FDHB500UK/Tanktopper
Tanktopper Series I, II & III
Tanktop Mounted Return Line Filters
with Integrated Air Breather
Degree of filtration
Average filtration beta ratio ß (ISO 16889) / particle size µm [c] Media
ßx(c)=2 ßx(c)=10 ßx(c)=75 ßx(c)=100 ßx(c)=200 ßx(c)=1000
code
% efficiency, based on the above beta ratio (ßx)
50.0% 90.0% 98.7% 99.0% 99.5% 99.9%
N/A N/A N/A N/A N/A 4.5 02Q/02QL
N/A N/A 4.5 5 6 7 05Q/05QL
N/A 6 8.5 9 10 12 10Q/10QL
6 11 17 18 20 22 20Q/20QL
Parker Hannifin
Hydraulic Filter Division Europe
68 FDHB500UK.
FDHB500UK/Tanktopper