FIRST AID - PARAMEDICAL - EMERGENCY

DUAL MODE DEFIBRILLATORS: AED+MANUALS WITH SpO2


AED
+
MANUAL


These two defibrillators
DBOCFVTFECPUIJOBVUPNBUJD "&%
BOENBOVBMNPEBMJUZ
Main features:
 - Synchronized cardioversion
- ECG monitoring mode (3 lead ECG cable)
7PJDFWFSTJPO  &OHMJTI *UBMJBO 4QBOJTI 'SFODI 1PSUVHVFTF 0UIFS - SpO2 monitoring with Nellcor SpO2 module (only CU-ER3)
BOENBOVBM       MBOHVBHFT
- Heart rate and SpO2 alarm system (only CU-ER3)
CU-ER 2       - CPR coaching in AED
CU-ER 3        - Efficient e~cube biphasic truncated exponential shock waveform
(*."DPEF "$$&4403*&4'03$6&3"/%$6&3 - Versatile power supply
 Disposable pads - kit of 2 pcs *German, Czech, - Intelligent data management system
 Pediatric disposable pads - kit of 2 pcs Japanese, Thai, ECG of patient is recorded all throughout the rescue operation, relevant
 ECG cable - 3 lead Chinese, Dutch. events (e.g. shock advised, charging, shock delivery) are recorded together
 Communication connector + software** for event with timestamp
recording download with key file Recorded data may be transferred to a PC for archiving and review or may
 Car cigar lighter jack be reviewed in the device
  Nellcor compatible SpO2 probe (only for CU-ER3) - Lightweight 2.7 kg (CU-ER2) 2.8 kg (CU-ER3) and highly portable.
 Rechargeable battery** Supplied with rechargeable battery, battery charger, adult pads with cable,
 Battery charger **Need CU-ER 2/3 serial number SpO2 module (CU-ER3 only), user manual and carrying bag.
5&$)/*$"-41&$*'*$"5*0/4
t&$(.POJUPS - Charging time: less than 10 seconds - Internal flash memory: 12 hours of - Power on self-test / Run time self-test
- Patient connection: defibrillation - Sensitivity & specificity: meets MMIguidelines event and ECG recording / Manual self-test
pads. ECG electrodes - Defibrillation electrodes: multifunctio- - Review the patient ECG. incident - Periodic self-test (daily/weekly/monthly)
- Bandwidth: monitoring mode: 0.3 to nal electrodes (disposable. pre-gelled) details and device information t"$BEBQUFS
40Hz (-3dB) t4Q0 $6&3POMZ
- Transmit multi patient data to PC - Input : 100 - 240V AC 50/ 60Hz 170VA
- EMS mode : 1 - 30Hz - Pulse rate: 20-250 bpm (±3bpm) t%JTQMBZ - Output: +12V DC 3.6A
- Heart rate: digital 30 to 300 bpm (±3bpm) - Saturation: 70-110% (± 3 digits) - Screen type: high resolution display t#BUUFSZQBDL
t%FmCSJMMBUPS t7PJDFUFYUQSPNQUT (Graphic LCD) - 12V 4.5Ah nickel-metal hydride batte-
AED + manual mode: variable energy - Voice prompts guide the user through - Screen size: 4 inches (10.16 cm) diago- ry pack (rechargeable)
level selection in 12 steps: 2,3,5,7,10,2 the rescue protocol nal. 320x240 pixels - Charging time: minimum of 4 hours
0,30,50,70,100,150,2005 - All user interfaces are supported in - Sweep speed: 25mm / sec. nominal for full charging
- Waveform: e-cube biphasic (biphasic local language - Viewing time: 3.2 seconds - Capacity: when new. minimum of 200
truncated exponential type) t%BUBTUPSBHFNBOBHFNFOU t"VUPNBUJDTFMGUFTU shock deliveries (fully charged)

DEFI-B BATTERY AND DEFI-N MAINS OPERATED DEFIBRILLATORS


In emergency situation the version and has proved successful in daily use in ambulances,
well structured and logical with cardio sport groups and in hospitals. DEFI-N is a mains
operator guidance may
operated version. The convincing advantages: PRIMEDIC
save a life
DEFI-B and DEFI-Nare quickly ready to use, DEFI-B not mains
Suitable for adult and
children (reference norms
dependent due to large accumulator capacity. After switching
ERC 2005 use of joule on the defibrillators, an internal self-test with error diagnosis
depending on kg). is carried out automatically. Pictograms and a clear program
run, to ensure functional handling. A shock-resistant plastic
Compact and handy: PRIMEDIC
DEFI-B is easily transportable casing protects the device, especially
and immediately ready to use in hard conditions.
everywhere t41"3&#"55&3:
5&$)/*$"-41&$*'*$"5*0/4
Mode: Asynchronous, external defibrillator
Energy step: 20, 50, 100, 160, 250, 360 Joule
Discharges: 45 shocks with 360 Joule,
0123 (10 reserve after signal "battery low")
Charging time:
 2 sec (33380-2) and 4 sec (33383) up to 100 Joule,
4.5 sec (33380-2) and 7.6 sec(33383) up to 360 Joule
t%&'*#%&'*#3*--"5037 Paddles for children integrated
t%&'*#%&'*#3*--"5037 Accumulator: 14.4V/1.4 Ah (33380-2 only)
Charging time: 3.5 hours (33380-2 only)
t%&'*/%&'*#3*--"5037 Safety: Internal discharge of energy after 15 sec.
The mobile security: PRIMEDIC DEFI-B and DEFI-N are a Internal self-testing and fault recognition
state-of-the-art accumulator-driven defibrillators. They were Protection class II, type BF
designed in accordance with strict requirements of emergency Mains voltage: 200-240 V 50/60 Hz or 110 V
medical science. Fully developed and reliable technique, world- Dimensions: 40x48x12 cm (W x D x H)
Weight: 8.5 kg Made in Germany
wide in use for years. PRIMEDIC DEFI-B is a mains-independent