Installation & Operation Manual: Package Terminal Air Conditioner - Heat Pump
Installation & Operation Manual: Package Terminal Air Conditioner - Heat Pump
INSTALLATION &
OPERATION MANUAL
.
MAN-IO-IPTH-0416
intensity.mx
CONTENTS
1. SAFETY PRECAUTIONS..................................................................2
6. INSTALLATION..................................................................................11
7. CARE AND CLEANING.....................................................................13
8. TROUBLESHOOTING.......................................................................14
! CAUTION
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play
the appliance. Cleaning and user maintenance shall not be made by children without
supervision. ( be applicable for the European Countries )
This appliance is not intended for use by persons (including children) with reduced
physical ,sensory or mental capabilities or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. (be applicable for other countries except the
European Countries )
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
The appliance with electric heater shall have at least 1 meter space to the combustible
materials.
Contact the authorised service technician for repair or maintenance of this unit.
Contact the authorised installer for installation of this unit.
1
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.
Never do this.
! Always do this.
! WARNING
! Plug in power plug Do not operate or stop the Do not damage or use an
properly. unit by inserting or pulling unspecified power cord.
out the power plug.
Otherwise, it may cause electric It may cause electric shock or fire It may cause electric shock or fire.
shock or fire due to excess heat due to heat generation. If the power cord is damaged, it
generation. must be replaced by the manufac-
turer or an authorised service
centre or a similarly qualified per-
son in order to avoid a hazard.
! Do not modify power cord Do not operate with wet Do not direct airflow at
length or share the outlet hands or in damp room occupants only.
with other appliances. environment.
It may cause electric shock or It may cause electric shock. This could damage your health.
fire due to heat generation.
! Always ensure effective Do not allow water to run !
Always install circuit
earthing. into electric parts. breaker and a dedicated
power circuit.
Incorrect earthing may cause It may cause failure of machine Incorrect installation may cause
electric shock. or electric shock. fire and electric shock.
! Unplug the unit if strange Do not use the socket if it is Do not open the unit
sounds, smell, or smoke loose or damaged. during operation.
comes from it.
It may cause fire and electric It may cause fire and electric It may cause electric shock.
shock. shock.
! Keep firearms away. Do not use the power cord Do not use the power cord near
close to heating appliances. flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
It may cause fire. It may cause fire and electric It may cause an explosion or fire.
shock.
! Ventilate room before operating air Do not disassemble or modify unit.
conditioner if there is a gas leakage from
another appliance.
It may cause explosion, fire and, burns. It may cause failure and electric shock.
2
! CAUTION
When the air filter is to be Do not clean the air ! Ventilate the room well when
removed, do not touch the conditioner with water. used together with a stove,
metal parts of the unit. etc.
It may cause an injury. Water may enter the unit and An oxygen shortage may occur.
degrade the insulation. It may
cause an electric shock.
! When the unit is to be Do not put a pet or house Do not use for special
cleaned, switch off, and turn plant where it will be purposes.
off the circuit breaker. exposed to direct air flow.
Do not clean unit when This could injure the pet or Do not use this air conditioner to
power is on as it may cause plant. preserve precision devices, food,
fire and electric shock, it may pets, plants, and art objects.
It may cause deterioration of
cause an injury. quality, etc.
Stop operation and close ! Turn off the main power
! ! Hold the plug by the head
the window in storm or of the power plug when switch when not using the
hurricane. taking it out. unit for a long time.
Operation with windows It may cause electric shock It may cause failure of product
opened may cause wetting and damage. or fire.
of indoor and soaking of
household furniture.
Do not place obstacles ! Ensure that the installation bracket of ! Always insert the filters
around air-inlets or inside the outdoor appliance is not damaged securely. Clean filter once
of air-outlet. due to prolonged exposure. every two weeks.
It may cause failure of If bracket is damaged, there Operation without filters may
appliance or accident. is concern of damage due to cause failure.
falling of unit.
Do not use strong deter- Do not place heavy object on the Do not drink water drained
gent such as wax or power cord and ensure that the cord from air conditioner.
thinner but use a soft cloth. is not compressed.
Appearance may be There is danger of fire or It contains contaminants and
deteriorated due to change electric shock. could make you sick.
of product color or
scratching of its surface.
! Use caution when unpacking and ! If water enters the unit, turn the unit off at the power
installing. Sharp edges could cause injury. outlet and switch off the circuit breaker. Isolate
supply by taking the power-plug out and contact a
qualified service technician.
! Clean the evaporator once every three
months by professional people.
3
IMPORTANT SAFETY INSTRUCTIONS
WARNING For your safety
NOTE The power supply cord with
this air conditioner contains a current Do not store or use gasoline or other flammable vapors and liquids in
detection device designed to reduce the vicinity of this or any other appliance.
the risk of fire. Avoid fire hazard or electric shock. Do not use an extension cord or an
,
Please refer to the section Operation adaptor plug. Do not remove any prong from the power cord.
,
of Current Device for details. WARNING Electrical Infor mation
In the event that the power supply
cord is damaged, it cannot be Be sure the electrical service is adequate for the model you have
repaired-it must be replaced with a chosen. This information can be found on the serial plate, which
cord from the Product Manufacturer. is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The power
Do not, under any
circumstances, cut, cord is equipped with a three-prong grounding plug for protection
remove, or bypass against shock hazards.
the grounding prong. Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or circuit breaker,
have a qualified electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place.
Power supply cord This could result in mechanical damage within the air conditioner.
with 3-prong grounding plug The appliance shall be installed in accordance with national wiring
and current detection device
regulations.
Do not use an extension cord or an adapter plug.
NOTE:
The shape may be different according to its model:
Power Cord
4
Operation of Cur rent Device(optional)
The power supply cord contains a current device that senses damage to the power cord. To test your power
supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head.
Press the TEST button, you will notice a click as the RESET
button pops out.
3. Press the RESET button, again you will notice a click as the button
engages.
4. The power supply cord is now supplying electricity to the unit.
(On some products this it also indicated by a light on the plug head.)
NOTES:
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be
reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the
product manufacturer.
When 265V units are to be installed,the power supply must be permanent wiring. Permanent
wiring may be done through the accessory subbase.An exposed cord connection on 265V units
are not permitted.
5
CONTROL PANEL OPERATION
The control panel keypad will look like the following Note: If the unit has DIP SWITCHES feature,the
Fig.1. For some models with REMOTE SIGNAL temperature range can be setted is controlled by
RECEPTOR, the unit can be controlled by the control DIP SWITCHES.See DIP SWITCHES CONFI-
panel alone or by the remote. NOTE: Some models GURATIONS on page 8 for details.
have no REMOTE SIGNAL RECEPTOR. UP/DOWN BUTTONS ( / )
REMOTE SIGNAL - Push the UP (or DOWN) button to increase (or
RECEPTOR
decrease) the set temperature of the unit in cooling
Fig.1 or heating mode. The temperature can be set by
increments of 1OC (1OF).The setting temperature
appears in the display.
NOTE: Press and hold and buttons together
for 3 seconds will alternate the temperature display
O O
between C & F scale.
POWER FAN (FAN SPEED)
- Press the POWER button to turn the unit on or off. - Every time you push this button, the fan speed
When the unit is on, the power indicator light will be cycles through the settings as follows: HIGH-MED-
green. When the unit is off, the light will go out. LOW-HIGH.
MODE DISPLAYS:
- Push this button to cycle through the modes from - Shows the set temperature in OC or OF. While on
COOL-HEAT-FAN-COOL. The indicator light beside Fan only mode, it shows the room temperature.
the "MODE" option will illuminate, identifying the Control code (on some models):
mode selected. LC-Pads on the control panel is not available. The
- COOL:The range of set temperature is 17OC/62OF unit can be setted by using wire cotroller only.
FC-Pads on the control panel and wire controller
~30OC/86OF. Cooling begins automatically when the
are not available. The unit can be setted by
room temperature is above the set point, and stops
using FRONT DESK CONTROL only.
when the room temperature is 2OC(4OF) below the
Error codes:
set point. But the compressor will run 5 minutes at
AS-Room temperature sensor error;
least in COOL mode before stoping. The fan runs
ES-Evaporator temperature sensor error;
in continuous mode.
CS-Condenser temperature sensor error;
- HEAT:The range of set temperature is 17OC/62OF
OS-Outside temperature sensor error;
~29OC/84OF. For heat pump models, the unit can
HS-Exhaust temperature sensor error;
alternate to run between in reverse cycle heat mode
LE-Wire cotroller error;
and electric heater mode according to the difference
NOTE:When error occurs, unplug the unit and plug
between the setting temperature and the room
it back in. If error repeats, call for service.
temperature. The fan motor cycles on and off
Other codes:
with the compressor and electric heater.
LO-Room temperature is lower than 0OC/32OF;
NOTE:
The reverse cycle and electric heater cannot be run at
HI-Room temperature is higher than 37OC/99OF;
the same time. In following cases, it is normal that the FP-Low temp. Protection.
reverse cycle does not operate. NOTE: All the illustrations in this manual are
1.When the outdoor temperatrue is lower than 4OC/40OF for explanation purpose only. Your air
or the room temperature falls to 4.5OC/8OF below the conditioner may be slightly different.
set point temperature. The actual shape shall prevail.
2.There is a 3-minute minimum compressor run time at NOTE:This air conditioner is designed to be
any setting to prevent short cycling. The indoor fan operated under condition as follows:
motors starts before the compressor and stops after
Cooling Outdoor temp: 18-43OC/64-109OF (18-52OC/64-125OF
the compressor cycles off.
for special tropical models)
3.Push the S1 on the DIP SWITCHES to UP (ON) operation
position. Indoor temp: 17-32 C/62-90OF
O
O O
4.When frost builds up to the evaporator coils, the unit Heating Outdoor temp: -5-24 C/23-76 F
O O
will defrost automatically and the compressor will cycle operation Indoor temp: 0-27 C/32-80 F
off.
Note: Performance may be reduced outside of
- FAN:Fan operation only without heating and cooling.
these operating temperatures.
6
CONTROL PANEL OPERATION CONTINUED
Accessory
7
DIP SWITCHES CONFIGURATIONS (Optional)
REMOVING THE FRONT PANEL 2
- Dip switches controls are located behind front panel,
through an opening below the control panel. To
access, remove front panel. See Fig.2.
- Dip switches are accessible without opening the
control box. See Fig.3.
- Unit must be powered OFF to effectively change
1
their status. - Pull out at the bottom to release it from the tabs 1 .
DIP SWITCHES CONFIGURATIONS - Then lift up 2 .
- See Table 1 and Fig.4 for Dip Switches configurations Fig.2
and functions of each dip switch position.
UP(ON)
1 2 3 4 1 2 3 4 1 2 1 2 3 4
DOWN(OFF) Dip Switches
S8
S7
S6
S5
S4
S3
S2
S1
S9
A0- A4 A5
X
A3
Wall thermostat type
Heating type
Temperature display type
Control type Fig.3
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for heating
Fan CON/CYC for cooling
Fig.4
Table 1 DIP SWITCHES CONFIGURATIONS
8
WALL THERMOSTAT TERMINAL (Optional)
IMPORTANT: Only trained, qualified personnel - Insert the wire connector of the wall thermostat into
should access electrical panel on unit and install the relevant terminal according to different shapes as
electrical accessories. Please contact your local shown below.
electrical contractor, dealer, or distributor for Terminal of some types of wall
assistance. thermostat
HEAT1
COMP
FC(L)
FC(N)
24V(N)
4-WAY
24V(L)
Dip switch
24V(N) 24VAC terminal N(Neutral),Common
24V(L) 24VAC terminal L
9
WALL THERMOSTAT TERMINAL (Optional)
FRONT DESK CONTROL
! CAUTION The controller can handle a switch signal from FC(L) and
UNIT DAMAGE HAZARD FC(N) input, called front desk control. Input must be 24VAC.
If system doesn't receive a 24VAC signal, it will turn unit
Failure to follow this caution may result in
off; otherwise, the unit runs in normal control.
equipment damage or improper operation.
Improper wiring may damage unit electronics. - The DIP switch can control the FRONT DESK CONTROL
Common busing is not permitted. Damage or feature. The DIP switch is on the DOWN position, the unit will
erratic operation may result. be turn off; otherwise,the unit runs in normal control.
NOTE: See FigB.
Use terminal 4-way for heat pump connection
only.
Suggest set the compressor protection time Dip switch of FRONT
more than 3 minutes in wall thermostat. If set less DESK CONTROL
than 3 minutes, the compressor will restart delay
3 minutes still.
Wall thermostat must be heating changeover 4-way
valve.
For thermostats that have only one fan speed
output (on or auto),the fan speed is determined Fig B.
by how the terminal connector is wired. If Low
fan is desired, wire the G output from the
thermostat to (LOW-FAN) on the units terminal
block. If High fan is desired, wire the G output
from the themostat to (HI-FAN) on the units
terminal block.
The range of set tempreture of Wall thermostat
must be in consonance with the range of DIP
switch setting.
Wall thermostat must be set the type properly
in consonance with the unit type : heat pump
or no heat pump.
If the Wall thermostat has only one electrical
heater output, connect the two terminals of HEAT 1
and HEAT 2, the unit can operate two electrical
heaters(only for the unit has two electrical
heaters). Otherwise operate one electrical heater.
Please do not remove the control panel.
10
INSTALLATION
HOW TO INSTALL THE UNIT Dimension of air conditioner
! CAUTION 1067mm/42inch
WALL SLEEVE
COOLED
AIR
HEAT
RADIATION
Shipping
Over 20 tape
INTAKE
AIR
WALL
Fig.3
2
Fig.2
PREPARATION OF SLEEVE ASSEMBLY(optional)
- Refer to the installation instruction of sleeve assembly
for details.
PREPARATION OF REAR GRILLE ASSEMBLY(optional)
- Refer to the installation instruction of rear grille 1
assembly for details. - Pull out at the bottom to release it from the tabs 1 .
UNIT INSTALLATION - Then lift up 2 .
Fig.4
- Carefully remove shipping tapes from the front panel.
(See Fig.3)
Shipping
- Remove the front panel. (See Fig.4) screw
Vent closed
Vent open
Fig.6
NOTE: When vent control lever set at CLOSE, only
the air inside the room is circulated and filtered.
When set at OPEN, some outdoor air will be drawn
into room. This will reduce heating or cooling
efficiency.
- Lift unit level and slide unit into wall sleeve until
firmly against front of wall sleeve and secure with
4 screws and washers (supplied in the SLEEVE
ASSEMBLY ) through the unit flange holes.
(See Fig.7 and Fig.8)
Fig.7
Fig.8
- Reinstall front panel. (See Fig.9)
1
Fig.9
12
CARE AND CLEANING
FRONT PANEL AND CASE - Removing Air Filter
- Turn unit off and disconnect power supply. To clean, 2 Air filters
use water and a mild detergent. DO NOT use bleach
and abrasivers. Some commercial cleaners may
Pull up
damage the plastic parts.
OUTDOOR COIL
- Coil on outdoor side of unit should be checked
regularly. Unit will need to be removed to inspect
dirt build-up that will occur on the inside of the coil.
If clogged with dirt and soot ,coil should be Fig.9
professionally cleaned. Clean inside and outside of - Replacing Air Filter
outdoor coils regularly.
NOTE: Never use a high-pressure spray on coil.
13
TROUBLESHOOTING
POSSIBLE CAUSES SOLUTONS
UNIT DOES NOT START Check that plug is plugged securely in wall receptacle.
Unit may have become unplugged Note:Plug has a test/reset button on it. Make sure that the plug has
Fuse may have blown not tripped.
Circuit breaker may have been tripped Replace the fuse. See Note 1.
Unit may be off Reset circuit breaker. See Note 1.
Unit may be in a protection mode. Turn unit on (bottom right button on keypad).
UNIT NOT COOLING/HEATING ROOM Make sure that curtains, blinds or furniture are not restricting or
Unit air discharge section is blocked blocking unit airflow.
Temperature setting is not high or low Reset to a lower or higher temperature setting.
enough Remove and clean filters.
Note: Setpoint limits may not allow the Allow sufficient amount of time for unit to heat or cool the room. Start
unit to heat or cool the room to the heating or cooling early before outdoor temperature, cooking heat or
temperature desired. Check section on gatherings of people make room uncomfortable.
dipswitch settings. Close vent door.
Unit air filters are dirty. Check dipswitch and wall thermostat settings for desired comfort.
Room is excessively hot or cold when Wait approximately 3 minutes for compressor to start.
unit is started.
Vent door left open.
Unit may be in a protection mode.
Compressor is in time delay.