RX 1
A REG
RST-1
RX 1
RST-2 10
Use the provided anchors and screws to mount the ISW-TRL8080 in Vs
GND
PGM
RX 2
OUT
PWR
11
RX 2
PANEL
TX PRG
1 OK
TXP 2 CLR
TXP
2.0 Configuration 17
GND
4
the translator data block.
Vs
1
GND
TX
5 - Connect RX on the serial receiver data block to RX2 on the
11
RX
6
Vs GND
7
NZ AUS
RX
TX
Vs
5- Reset button
TAMPER
TX Vs GND RX
OUT 1
(DCC)
GND
GND
RX 2
GND
RX 1
TX 2
TX 1
TXP
9 - TX (transmit) LED
TX PRG
Vs
Vs
PANEL
RCVR
RX 1
TX 2
TX 1
TXP
2 | F01U126804-03 | 11/09 ISW-EN7280 Serial Receiver Installation Guide © 2009 Bosch Security Systems, Inc.
3.2 Receiver-to-Translator Direct Serial Connection Figure 4: ISW-D8125CW to ISW-TRL8080 Wiring
If desired, you can install the translator into the serial receiver’s
housing so that both devices share the housing. 4
To add the translator to the serial receiver’s housing:
ISW-EN4200 #1 ISW-EN4200 #2
1. Remove the printed circuit board (PCB) from the translator’s
housing.
GND Vs RX TX GND Vs RX TX
2. Align the mating connector with the serial receiver’s serial data
port, and then slide the translator’s PCB into the receiver’s
housing.
3. Ensure that the data ports connect using the mating connector,
and then press down to click the translator’s PCB into place. 2
© 2009 Bosch Security Systems, Inc. ISW-EN7280 Serial Receiver Installation Guide 11/09 | F01U126804-03 | 3
5. Connect the white wire to the GND connection on the Table 1 (continued): ISW-TRL8080 LEDs
translator’s TX PRG terminal block.
LED Description
6. Plug the Transmitter Programming Cable’s black connector RST-1 Receiver 1 Reset Message LED
onto the Transmitter Programming port.
• Lights when the first reset message is
If connecting two ISW-D8125CW Commercial Wireless received from a transmitter.
Interface Modules to the translator, they will share the • Blinks slowly when Receiver 1 is inactive.
Vs, GND and TXP connections on the translator’s • Blinks quickly when a selection jumper is
panel data block. placed in the CLR position on the MAP
selection pins.
4.0 Register the System’s Transmitters RST-2 Receiver 2 Reset Message LED
You must register all transmitters and repeaters with the • Lights when the last reset message is
ISW-D8125CW Commercial Wireless Interface Module and with the received from a transmitter.
TRL8080. Bosch wireless devices employ wireless registration, so • Blinks slowly when Receiver 2 is inactive.
there is no need to connect the transmitter to the ISW-D8125CW.
No data is written to the transmitter during registration. • Blinks quickly when a selection jumper is
placed in the CLR position on the MAP
To register transmitters and repeaters: selection pins.
1. Program the transmitter as described in the ISW-D8125CW PGM Programming Complete LED
Commercial Wireless Interface Module Operation and Installation
• Lights when programming is completed
Guide (P/N: F01U133410).
• Blinks quickly when a selection jumper is
2. When prompted, on the transmitter, press the RESET button, placed in the CLR position on the MAP
press the end device’s RESET button once if the ISW-TRL8080 selection pins.
is set to accept registration after a single reset message, and
OUT Data Transmission LED
twice if the ISW-TRL8080 is set for a double button push.
Lights when data is transmitted to and from the
- The RST-1 LED on the ISW-TRL8080 lights when the first control panel.
reset message is received.
PWR Power LED
- The RST-2 LED on the ISW-TRL8080 lights when the last Lights when the translator is receiving power.
reset message is received. The ISW-TRL8080 uses this LED
only when in double button push mode. 5.2 ISW-EN4200 Operation
3. After registering each transmitter and repeater, ensure an Use the following LEDs to monitor serial receiver operation.
appropriate response from your control panel.
Refer to Table 2 below and Figure 2, page 2.
4. Ensure that each transmitter and repeater also registers with
the ISW-TRL8080. As each unit registers successfully with the Table 2: ISW-EN4200 LEDs
ISW-TRL8080, the ISW-TRL8080’s green PGM LED lights. LED Description
5.0 Operation TX Transmit LED
Lights when the serial receiver is transmitting
5.1 ISW-TRL8080 Operation data to the application controller.
Use the following LEDs to monitor translator operation. RX Receive LED
Refer to Table 1 below, and Figure 1, page 1. Lights when the serial receiver is receiving data
from the application controller.
Table 1: ISW-TRL8080 LEDs
DEC Decode LED
LED Description
Lights when the serial receiver is decoding an RF
TX1 Receiver 1 Transmit LED transmission from another wireless device.
Lights when the translator is transmitting data to
the serial receiver or network coordinator. 6.0 Specifications
RX1 Receiver 1 Receive LED Housing Dimensions 162 x 91.4 x 27.9 mm
Lights when the translator is receiving data from (H x W x D) (6.4 x 3.6 x 1.1 in.)
the serial receiver or network coordinator.
Weight 14.2 g (0.5 oz)
TX2 Receiver 2 Transmit LED
Power Requirements 12 VDC at 1 W
Lights when the translator is transmitting data to
Operating Environment 0° to 60°C (32° to 140°F), 90%
the second RF gateway.
relative humidity, non-condensing
RX2 Receiver 2 Receive LED
Lights when the translator is receiving data from
the second RF gateway.
TXP Transmitter Programming LED
Lights when the translator is sending or receiving
transmitter programming data.