Professional Documents
Culture Documents
Safe and Reliable GT Operation Ensured by Unique High Temperature Measuring Technique
Safe and Reliable GT Operation Ensured by Unique High Temperature Measuring Technique
GT operation
ensured by unique
high temperature
measuring technique
www.kistler.com/thermoacoustics
©2016, Kistler Group
Description
The sensor features a shear design, which significantly reduces
• Temperature range -55 … 260oC
the influence of temperature and base strain. Other features are
• Sensitivity 20, 50 and 100 pC/g
a high frequency response and a hermetic construction of the
• Differential output
housing.
960-662e-12.16
• Frequency response 1 Hz … 10kHz (±10%)
• Hermetically welded construction
The sensor provides a differential signal output and features an
• Ex-certification for use in potentially explosive environment
internally case isolated design. It is available without cable in a
• Integrated cable version with specific degree of protection
connector version, or alternatively, equipped with a shielded low
• ARNIC 3-point fixation
noise, AWG 22, twisted pair high temperature integral cable with
• EMI resistant measuring chain
standard lengths up to 20 meters and different cable protection
systems to suit various applications.
8205B_C
8205B_D
8205B_E
Kistler Group
Eulachstrasse 22
8408 Winterthur
Switzerland
Tel. +41 52 224 11 11