Microjet Recorder (180Mm) : Features
Microjet Recorder (180Mm) : Features
FEATURES
1. Compact size
Compact and lightweight design, 199mm in depth and
about 6kg in mass{weight}.
2. High quality recording
• Ink jet system is used for recording and printing
measured data in 6 different colors at a high speed.
Operating noise is minimized.
• Six and twelve continuous traces without pen offset 6. Easy handling
are possible with this compact size of recorder; a • A cartridge type recording device is used for easy
unique recording system is used for the first time in replacement.
the industry. • Chart paper can be loaded without drawing out the
• Scale of each channel is printed on chart paper, internal unit of the recorder.
elimi- nating the need for scales. • Shortage of ink is detected in early stages and an
3. Easy setting of input signals alarm is given to the operator.
DC voltage input (5mV span, 50V max.), 12 kinds of • The end of chart paper is detected and indicated on
thermocouples (Type B, R, S, K, E, J, T, N, W, L, U, PN) the front panel display.
and resistance bulbs (Pt100) can be set for each chan- • Shortage of ink and the end of chart paper alarm
nel. output is possible.
4. Digital printing 7. Full variety of functions
Beside the analog recording of measured data, digital • Alarm relay output/external control (record start/
printing is also available (periodic printing, list printing, stop, chart speed change, data printing, message
alarm printing, daily report printing, message printing). printing). This unit can easily be connected to the
• Periodic data printing: Channel No., date, time, unit, recorder by user (option).
chart speed, measured value • Chart paper illumination lamp (option): The result of
• List printing: Date, time, unit, recording range, scal- printing can be checked even in lower light.
ing value, alarm set value, chart speed, Tag No. • Burnout function is provided as a standard.
• Alarm printing: Channel No., alarm type, on/off time, • Various recording: Enlarged/reduced recording,
output relay No. auto-range recording, zone recording.
• Daily report and totalized data printing: Printing of • Calculation: Square root extraction, subtraction, en-
maximum, minimum, average and total of data gineering unit conversion, logarithm.
measured during maximum 24 hours • Language: Selectable 3 languages in display and
• Message printing : 10 messages, 16-character user- printing.
entered messages • Passcode security is configurable.
5. Interactive key operation • The message print and alarm print function are op-
Fluorescent indicator is used to clearly indicate alpha- erational, even when the recording mode is off.
numeric characters and symbols. • All parameters of recording format, daily report,
Input mode, recording range, alarm value, chart speed, totalize, message and periodic data printing can be
etc., can be set according to the comments indicated printed cut.
by the display and operating keys. No bothersome op-
eration is required.
EDSX10-60m
Date Nov. 24, 2011
PHA
4
2. Alarm output/3-point external control:
Periodic data Time, date, chart speed, measured value and unit
This unit can be mounted from the printing function can be printed at fixed intervals.
rear side of the recorder. Printing can be enabled/disabled from keyboard.
(1) Alarm output (DO): Message Maximum 10 messages, 16- character user-
6 or 12 points of relay contact N.O. (1a) printing entered messages can be printed.
output for individual channel opera- Alarm printing Time, channel No., kind of alarm, and output re-
tion or common operation function lay No. can be printed when alarm is on or off.
Maximum contact voltage 240V AC, Unit indication Engineering units such as °C, °F, %, mV, mA,
30V DC Pa,L, etc., are indicated (setting from key board).
Maximum contact current 3A Scaling function Scaling with DC voltage input is possible.
(Setting of decimal point is also possible within
(resistive load) the range of –32767 to +32767).
(2) External control (DI):
Subtract function Difference between any channels is recorded
The following control is possible with (channel is set from keyboard).
external contact signal.
Logarithm Measured value can be displayed and printed by
• Recording start/stop; 10n power
Recording start/stop is effected
Auto-range Recording range is automatically changed for re-
by contact signal. Recording is recording cording in the event of overrange or underrange
started when contact is closed and (setting with keyboard).
This function is not available for combination of
stopped when contact is open. zone recording and enlarged/reduced recording.
• Chart speed change;
Zone recording Recording area is divided into a maximum of 4
Selection between normal and re- zones for recording.
mote chart speeds is effected by This function is not available for combination of
automatic range selection and enlarged/reduced
contact signal. Remote chart speed recording.
is selected when contact is closed
Enlarged/reduced A part of recording area of each channel is ex-
and normal when contact is open. recording panded or contracted for recording.
• Measured value printing; This function is not available for combination of
automatic range selection and zone recording.
Measured value list printing (date,
Square-root ex- Square-root extraction of DC voltage input is pos-
time, channel No., measured value, traction function sible.
unit) is effected by contact signal.
Daily report Measured value of every hour for maximum one
Printing is started when contact is function day (24 data) in each channel is stored for print-
closed. ing. Maximum, minimum and average values are
also printed at the same time.
• Message printing ON-OFF operation, ON-OFF of each channel and
operation start time/stop time can be set from
Note: For external control, use a dry con- keyboard.
tact.
Contact capacity: 12V DC, 0.05A, Totalize function Integrated value of every hour for maximum one
day (24 data) in each channel is stored for print-
N.O. (1a) contact
ing (integration in 1 sec steps). Possible to print
total value only.
3. Transmission function: Total value is also printed at the same time.
ON-OFF operation, ON-OFF of each channel and
T-link interface for transmitting meas- operation start time/stop time can be set from
keyboard.
ured value and receiving the condi-
tion of setting.
Measured value Shift the zero point and inclination of the mea-
shift sured value so that the measured value can be
adjusted according to other instruments.
Transmission
method Half-duplex bit serial
Memory backup Set data and clock function are protected by
Transmission speed 500kbps built-in lithium battery (expected battery life,
about 10 years under normal temperature).
Transmission distance Max. 500m Input filter Response is delayed according to sudden chang-
es in input of each channel (1st order lag filter).
I/O frame 8w or 16w Time constant setting range: 0 to 900 sec (setting
from keyboard).
Available to set/change param-
Message frame Burnout function When thermocouple or resistance bulb input is
eters etc.
disconnected, it is deflected 100%. Also, it is
indicated and printed at the same time.
Passcode 4 digits passcode security is available.
5
PHA
PHA
6
OUTLINE DIAGRAMS (Unit:mm)
Alarm unit(option)
2 T 30
(Alarm 7 to 12)
t
Alarm/external control Mounting
unit(option) bracket Panel
Transmission terminal
(Alarm 1 to 6, DI 1 to 3)
(option)
Input terminal 2
(Input 7 to 12)
280
288
Input terminal 1 Power terminal
(Input 1 to 6)
280 39 160 288
312 199 18
360 min.
Panel cutout
281+20
281+20
320 min.
CONNECTION DIAGRAMS
Input terminal 2 Input terminal 1 Alarm unit Alarm/external control Transmission
(option) unit (option) terminal
(Alarm 7 to 12) (Alarm 1 to 6, DI 1 to 3) (option)
Terminal Terminal
Thermocouple No. No.
Resistance Voltage 71 11
buld + + DI 1 TRX1 TRX2 SHLD
72 Input 7 12 Input 1 11 21
– – + –
73 13 DI 2
12 22
81 21
82 Input 8 22 Input 2 13 23 DI 3 Power terminal
83 23
91 31 31 41 Alarm 7 14 24 Alarm 1 AC AC G
7
PHA
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.