Project: GSC PHASE 1 (Mechanical RETAIL area)

Location: Ortigas ave., Greenhills, San Juan, Metro Manila


Subject: AHU, FANS and BLOWER MONITORING START-UP & FUNCTIONALITY SCHEDULE
Date: MARCH 22, 2022

ITEM EQUIPMENT TAGGING QTY MOTOR KW / HP ELECTRICAL V / ø / Hz ACTIVITY START DATE END DATE Location Mall 1 / 2

LOWER GROUND FLOOR


1 AHU-LG-01 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Sunday, February 13, 2022 Wednesday, February 23, 2022 2 (on-hold)
2 AHU-LG-02 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Sunday, February 13, 2022 Wednesday, February 23, 2022 2 (on-hold)
3 AHU-LG-03 1 3.73kw / 5hp 400 / 3 / 60 Start-up/Functionality Test Wednesday, August 31, 2022 Saturday, September 10, 2022 2 (on-hold)
4 AHU-LG-04 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Wednesday, August 31, 2022 Saturday, September 10, 2022 2 (on-hold)
5 AHU-LG-05 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Sunday, September 11, 2022 Wednesday, September 21, 2022 1
7 AHU-LG-07 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Thursday, September 22, 2022 Sunday, October 2, 2022 1
8 AHU-LG-08 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test Thursday, September 22, 2022 Sunday, October 2, 2022 1
9 AHU-LG-09 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test Monday, October 3, 2022 Thursday, October 13, 2022 1
10 AHU-LG-10 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test Monday, October 3, 2022 Thursday, October 13, 2022 1
11 AHU-LG-11 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test Friday, October 14, 2022 Monday, October 24, 2022 1
12 AHU-LG-12 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test Friday, October 14, 2022 Monday, October 24, 2022 1
GROUND FLOOR
13 AHU-GF-02 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Tuesday, October 25, 2022 Friday, November 4, 2022 2 (on-hold)
14 AHU-GF-03 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test Tuesday, October 25, 2022 Friday, November 4, 2022 2 (on-hold)
15 AHU-GF-04 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test Saturday, November 5, 2022 Tuesday, November 15, 2022 1
16 AHU-GF-05 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test Saturday, November 5, 2022 Tuesday, November 15, 2022 1
17 AHU-GF-06 1 11.19kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Sunday, February 13, 2022 Wednesday, February 23, 2022 1
18 AHU-GF-07 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Wednesday, August 31, 2022 Tuesday, November 15, 2022 1
19 AHU-GF-08 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
20 AHU-GF-09 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
21 AHU-GF-10 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
22 AHU-GF-11 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
23 AHU-GF-12 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
SECOND FLOOR
24 AHU-2F-03 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
25 AHU-2F-04 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
26 AHU-2F-05 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
27 AHU-2F-06 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
28 AHU-2F-07 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
29 AHU-2F-08 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
30 AHU-2F-09 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
31 AHU-2F-10 1 3.73kw / 5hp 400 / 3 / 60 Start-up/Functionality Test 1
32 AHU-2F-12 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
33 AHU-2F-13 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
34 AHU-2F-14 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
35 AHU-2F-15 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
36 AHU-2F-16 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
THIRD FLOOR
37 AHU-3F-01 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
38 AHU-3F-02 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
39 AHU-3F-03 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
40 AHU-3F-04 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
41 AHU-3F-05 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
42 AHU-3F-06 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
43 AHU-3F-07 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
44 AHU-3F-08 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
45 AHU-3F-09 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
47 AHU-3F-11 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
48 AHU-3F-12 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
49 AHU-3F-13 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
50 AHU-3F-14 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
51 AHU-3F-15 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
FOURTH FLOOR
52 AHU-4F-01 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
53 AHU-4F-02 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
54 AHU-4F-03 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
55 AHU-4F-04 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
56 AHU-4F-05 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
57 AHU-4F-06 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
59 AHU-4F-08 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
60 AHU-4F-09 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
61 AHU-4F-10 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
62 AHU-4F-11 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 2 (on-hold)
63 AHU-4F-12 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
64 AHU-4F-13 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
65 AHU-4F-14 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
66 AHU-4F-15 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test 1
67 AHU-4F-16 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
FIFTH FLOOR
68 AHU-5F-01 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
69 AHU-5F-02 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
70 AHU-5F-03 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 1
71 AHU-5F-04 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
74 AHU-5F-07 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test 1
75 AHU-5F-08 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
76 AHU-5F-09 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
77 AHU-5F-10 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1
78 AHU-5F-12 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test Cinema/ on-hold
79 AHU-5F-15 1 3.73kw / 5hp 400 / 3 / 60 Start-up/Functionality Test Cinema/ on-hold
80 AHU-5F-16 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Cinema/ on-hold
81 AHU-5F-17 1 5.6kw / 7.5hp 400 / 3 / 60 Start-up/Functionality Test Cinema/ on-hold
82 AHU-5F-18 1 7.46kw / 10hp 400 / 3 / 60 Start-up/Functionality Test
83 AHU-5F-19 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test
SIX FLOOR
87 AHU-6F-02 1 11.19kw / 15hp 400 / 3 / 60 Start-up/Functionality Test 2
88 AHU-6F-03 1 14.92kw / 20hp 400 / 3 / 60 Start-up/Functionality Test 1

Prepared by:

Ariel R. Lambon
CISC-QA/QC Engr.
REQUIRED POWER SUPPLY

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent P
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Project: GSC PHASE 1 (Mechanical RETAIL area)
Location: Ortigas ave., Greenhills, San Juan, Metro Manila
Subject: AHU, FANS and BLOWER MONITORING START-UP & FUNCTIONALITY SCHEDULE
Date: MARCH 22, 2022

Capacity QTY MOTOR RATING


ITEM EQUIPMENT TAGGING Activity Start Date End Date Location Mall 1 / 2
LPS HP V Ph Hz
BASEMENT LEVEL
1 CEF-B11 13,923 8 7.5 400 3 60 Start-up/Functionality Test Basement 1
2 CEF-B21 13,923 8 7.5 400 3 60 Start-up/Functionality Test Basement 2
3 CEF-B31 13,923 8 7.5 400 3 60 Start-up/Functionality Test Basement 3
4 CSF-B11 13,923 8 5 400 3 60 Start-up/Functionality Test Basement 1
5 CSF-B21 13,923 8 5 400 3 60 Start-up/Functionality Test Basement 2
6 CSF-B31 13,923 8 5 400 3 60 Start-up/Functionality Test Basement 3
7 EF-B2-1 156 0.33 230 1 60 Start-up/Functionality Test on-hold
8 EF-B41 2,210 1 1.5 400 3 60 Start-up/Functionality Test Mall 1
9 EF-B42 4,830 1 5 400 3 60 Start-up/Functionality Test Mall 1
10 EF-LG-1 472 1 0.5 230 1 60 Start-up/Functionality Test Mall 1
11 EF-LG-01 1,871 1 2 400 3 60 Start-up/Functionality Test Mall 1
12 EF-LG-3F-01 4,113 1 3 400 3 60 Start-up/Functionality Test Mall 1
13 EF-51-A,B,C&D 2,952 4 2 400 3 60 Start-up/Functionality Test McKinley Area.
14 EF-52-A,B,C,D,E & F 2,952 6 2 400 3 60 Start-up/Functionality Test McKinley Area.
15 EF-5F-01 3,560 1 3 400 3 60 Start-up/Functionality Test Mall 1
16 EF-5F-02 3,560 1 3 400 3 60 Start-up/Functionality Test Mall 1
17 IJF-1 1,954/1,297 115 3 / 1.5 400 3 60 Start-up/Functionality Test Mall 1 & 2

LOWER GROUND FLOOR


18 KEF-LG-01 12,137 1 20 400 3 60 Start-up/Functionality Test Mall 1
19 KEF-LG-02 7,315 1 15 400 3 60 Start-up/Functionality Test Mall 1
20 KEF-LG-03 10,316 1 15 400 3 60 Start-up/Functionality Test Mall 1
21 KEF-LG-04 7,331 1 15 400 3 60 Start-up/Functionality Test Mall 1
23 KEF-LG-06 5,893 1 10 400 3 60 Start-up/Functionality Test Mall 1
24 KEF-LG-07 6,934 1 10 400 3 60 Start-up/Functionality Test Mall 1
25 KEF-LG-08 9,733 1 15 400 3 60 Start-up/Functionality Test Mall 1
26 KEF-LG-09 7,079 1 10 400 3 60 Start-up/Functionality Test Mall 1
27 KEF-LG-10 5,899 1 10 400 3 60 Start-up/Functionality Test Mall 1
28 KEF-LG-11 1,085 1 2 400 3 60 Start-up/Functionality Test McKinley Area.
GROUND FLOOR
29 KEF-GF-01 6,993 1 10 400 3 60 Start-up/Functionality Test Mall 1
30 KEF-GF-02 9,040 1 15 400 3 60 Start-up/Functionality Test Mall 1
31 KEF-GF-03 7,109 1 10 400 3 60 Start-up/Functionality Test Mall 1
32 KEF-GF-04 9,322 1 15 400 3 60 Start-up/Functionality Test Mall 1
33 KEF-GF-05 8,029 1 15 400 3 60 Start-up/Functionality Test Mall 1
34 KEF-GF-06 8,209 1 15 400 3 60 Start-up/Functionality Test Mall 1
35 KEF-GF-07 9,807 1 15 400 3 60 Start-up/Functionality Test Mall 1
36 KEF-GF-08 6,761 2 15 400 3 60 Start-up/Functionality Test Mall 1 & 2
37 KEF-GF-09 6,326 1 15 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
SECOND FLOOR
38 KEF-2F-5F-01 7,653 1 15 400 3 60 Start-up/Functionality Test Mall 1
39 KEF-2F-02 9,369 1 15 400 3 60 Start-up/Functionality Test Mall 1
40 KEF-2F-03 6,714 1 10 400 3 60 Start-up/Functionality Test Mall 1
41 KEF-2F-05 6,554 1 10 400 3 60 Start-up/Functionality Test Mall 1
42 KEF-2F-06 7,359 1 15 400 3 60 Start-up/Functionality Test Mall 1
THIRD FLOOR
43 KEF-3F-01 4,692 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
44 KEF-3F-02 7,386 1 15 400 3 60 Start-up/Functionality Test Mall 1
45 KEF-3F-03 5,184 1 10 400 3 60 Start-up/Functionality Test Mall 1
Capacity QTY MOTOR RATING
ITEM EQUIPMENT TAGGING Activity Start Date End Date Location Mall 1 / 2
LPS HP V Ph Hz
46 KEF-3F-04 8,349 1 15 400 3 60 Start-up/Functionality Test Mall 1
47 KEF-3F-05 7,342 1 15 400 3 60 Start-up/Functionality Test Mall 1
48 KEF-3F-06 8,158 1 15 400 3 60 Start-up/Functionality Test Mall 1
49 KEF-3F-07 8,204 1 15 400 3 60 Start-up/Functionality Test Mall 1
50 KEF-3F-08 3,744 1 5 400 3 60 Start-up/Functionality Test McKinley Area.
FOURTH FLOOR
51 KEF-4F-01 4,744 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
52 KEF-4F-06 8,328 1 15 400 3 60 Start-up/Functionality Test Mall 1
53 KEF-4F-07 8,158 1 15 400 3 60 Start-up/Functionality Test Mall 1
54 KEF-4F-08 5,906 1 10 400 3 60 Start-up/Functionality Test Mall 1
FIFTH FLOOR
55 KEF-5F-01 4,871 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
56 KEF-5F-02 9,549 1 15 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
57 KEF-5F-03 9,196 1 15 400 3 60 Start-up/Functionality Test Mall 1
58 KEF-5F-06 7,401 1 15 400 3 60 Start-up/Functionality Test Mall 1
SIX FLOOR
59 KEF-6F-02 6,525 1 7.5 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
60 KEF-6F-03 6,363 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
61 KEF-6F-04 5,451 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
62 KEF-6F-05 6,888 1 10 400 3 60 Start-up/Functionality Test Mall 1
63 KEF-6F-06 10,917 1 15 400 3 60 Start-up/Functionality Test Mall 1
64 KEF-6F-07 9,538 1 15 400 3 60 Start-up/Functionality Test Mall 1
65 KEF-6F-08 4,795 7.5 400 3 60 Start-up/Functionality Test Mall 1
66 KEF-6F-11 10,774 1 15 400 3 60 Start-up/Functionality Test Mall 1
67 KEF-6F-12 5,048 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
LOWER GROUND FLOOR
68 KSF-LG-01 9,710 1 15 400 3 60 Start-up/Functionality Test Mall 1
69 KSF-LG-02 5,708 1 10 400 3 60 Start-up/Functionality Test Mall 1
70 KSF-LG-03 7,671 1 10 400 3 60 Start-up/Functionality Test Mall 1
71 KSF-LG-04 6,445 1 10 400 3 60 Start-up/Functionality Test Mall 1
72 KSF-LG-05 1,085 1 2 400 3 60 Start-up/Functionality Test McKinley Area.
GROUND FLOOR
73 KSF-GF-01 5,595 1 10 400 3 60 Start-up/Functionality Test Mall 1
74 KSF-GF-02 3,934 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
75 KSF-GF-03 2,823 1 3 400 3 60 Start-up/Functionality Test McKinley Area.
Capacity QTY MOTOR RATING
ITEM EQUIPMENT TAGGING Activity Start Date End Date Location Mall 1 / 2
LPS HP V Ph Hz
76 KSF-GF-04 8,469 1 10 400 3 60 Start-up/Functionality Test Mall 1
77 KSF-GF-05 10,602 1 10 400 3 60 Start-up/Functionality Test Mall 1
SECOND FLOOR
78 KSF-2F-05 5,608 1 5 400 3 60 Start-up/Functionality Test Mall 1
79 KSF-2F-06 8,346 1 10 400 3 60 Start-up/Functionality Test Mall 1
80 KSF-2F-07 8,346 1 10 400 3 60 Start-up/Functionality Test Mall 1
81 KSF-2F-08 8,346 1 10 400 3 60 Start-up/Functionality Test Mall 1
82 KSF-2F-09 8,346 1 10 400 3 60 Start-up/Functionality Test Mall 1
THIRD FLOOR
83 KSF-3F-01 3,754 1 5 400 3 60 Start-up/Functionality Test Mall 1
84 KSF-3F-02 6,564 1 7.5 400 3 60 Start-up/Functionality Test McKinley Area.
85 KSF-3F-03 6,679 1 7.5 400 3 60 Start-up/Functionality Test McKinley Area.
86 KSF-3F-04 2,995 1 5 400 3 60 Start-up/Functionality Test McKinley Area.
87 KSF-4F-01 3,795 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
FIFTH FLOOR
90 KSF-5F-01 3,897 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
91 KSF-5F-02 6,860 1 10 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
92 KSF-5F-03 7,357 1 15 400 3 60 Start-up/Functionality Test Mall 1
93 KSF-5F-06 7,401 1 15 400 3 60 Start-up/Functionality Test Mall 1
SIX FLOOR
94 KSF-6F-02 5,220 1 5 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
95 KSF-6F-03 5,091 1 5 400 3 60 Start-up/Functionality Test Mall 1
96 KSF-6F-04 4,361 1 5 400 3 60 Start-up/Functionality Test Mall 1
97 KSF-6F-05 5,510 1 5 400 3 60 Start-up/Functionality Test Mall 1
98 KSF-6F-06 8,733 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
99 KSF-6F-07 7,630 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
100 KSF-6F-08 3,836 1 5 400 3 60 Start-up/Functionality Test Mall 1
101 KSF-6F-11 8,181 1 15 400 3 60 Start-up/Functionality Test Mall 1
102 KSF-6F-12 4,030 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
SIX FLOOR ROOFDECK
103 LPF-01,02,3,04 4,000 4 5 400 3 60 Start-up/Functionality Test
104 SEF-1 25,097 1 40 400 3 60 Start-up/Functionality Test Mall 1
105 SEF-2,3,6,7,8 13,252 5 25 400 3 60 Start-up/Functionality Test Mall 1
106 SEF-4,5,9 13,252 3 25 400 3 60 Start-up/Functionality Test Mall 1
107 SEF-10A 10,562 1 10 400 3 60 Start-up/Functionality Test Mall 1
108 SEF-10B 15,686 1 20 400 3 60 Start-up/Functionality Test Mall 1
109 SEF-10C 11,439 1 15 400 3 60 Start-up/Functionality Test Mall 1
110 SEF-10D 8,091 1 10 400 3 60 Start-up/Functionality Test Mall 1
111 SEF-11A 5,344 1 7.5 400 3 60 Start-up/Functionality Test Mall 1
112 SEF-11B 7,236 1 10 400 3 60 Start-up/Functionality Test Mall 1
113 SEF-12A 8,860 1 15 400 3 60 Start-up/Functionality Test Mall 1
114 SEF-12B 8,860 1 15 400 3 60 Start-up/Functionality Test Mall 1
115 SF-B41 4,830 1 5 400 3 60 Start-up/Functionality Test Mall 1
116 SF-LG-01 1,871 1 1.5 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
117 SF-2F-01 4,112 1 3 400 3 60 Start-up/Functionality Test Mall 1
118 SF-5F-01 3,560 1 3 400 3 60 Start-up/Functionality Test Mall 1
119 SF-5F-02 2,524 1 3 400 3 60 Start-up/Functionality Test Mall 1
120 SPF-01,02,03,04,06 4,000 5 10 400 3 60 Start-up/Functionality Test
121 SPF-05,11 4,400 2 10 400 3 60 Start-up/Functionality Test
122 SPF-09,10 2,973 2 10 400 3 60 Start-up/Functionality Test
123 TEF-B11 198 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
124 TEF-B12 180 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
125 TEF-B13 70 1 0.167 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
126 TEF-B14 47 4 0.167 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
127 TEF-B21 198 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
Capacity QTY MOTOR RATING
ITEM EQUIPMENT TAGGING Activity Start Date End Date Location Mall 1 / 2
LPS HP V Ph Hz
128 TEF-B22 180 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
129 TEF-LG1 231 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
130 TEF-LG2 198 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
131 TEF-LG3 378 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
132 TEF-LG4 444 1 0.33 230 1 60 Start-up/Functionality Test Mall 1 (on-hold)
133 TEF-LG5 267 1 0.33 230 1 60 Start-up/Functionality Test Mall 2 (on-hold)
134 TEF-LG6 293 1 0.33 230 1 60 Start-up/Functionality Test Mall 2 (on-hold)
135 TEF-1 4,848 1 5 400 3 60 Start-up/Functionality Test Mall 1
136 TEF-51 994 1 1 230 1 60 Start-up/Functionality Test Mall 2 (on-hold)
137 TEF-52 2,012 1 1.5 400 3 60 Start-up/Functionality Test Mall 2 (on-hold)
138 TEF-61 697 1 1 400 3 60 Start-up/Functionality Test Mall 1
139 TEF-62 820 1 1 400 3 60 Start-up/Functionality Test Mall 1
140 WEF-LG1 1,911 1 0.75 230 1 60 Start-up/Functionality Test Mall 1
141 WEF-GF1 1,935 2 0.75 400 3 60 Start-up/Functionality Test Mall 1
142 WEF-4F1 1,935 3 0.75 400 3 60 Start-up/Functionality Test McKinley Area.
143 WEF-5F1 3,351 7 1 400 3 60 Start-up/Functionality Test McKinley Area.
CINEMA
144 EF-5F-C1 28 2 0.054KW 230 3 60 Start-up/Functionality Test CINEMA
145 EF-5F-C2 71 2 0.186KW 230 3 60 Start-up/Functionality Test CINEMA
146 EF-6F-C1 71 1 0.186KW 230 3 60 Start-up/Functionality Test CINEMA
147 KEF-5F-C1 1392 1 2.24 KW 400 3 60 Start-up/Functionality Test CINEMA
148 KSF-5F-C1 566 1 0.373KW 230 3 60 Start-up/Functionality Test CINEMA
149 TEF-51 944 1 0.5595KW 230 3 60 Start-up/Functionality Test CINEMA
150 TEF-5F-C1 57 2 0.054KW 230 3 60 Start-up/Functionality Test CINEMA
151 TEF-5F-C2 198 3 0.186KW 230 3 60 Start-up/Functionality Test CINEMA
152 TEF-5F-C3 227 1 0.186KW 230 3 60 Start-up/Functionality Test CINEMA
REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Additional Based on TM4
Additional Based on TM4

Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
REMARKS

Additional Based on TM4


Additional Based on TM4

Additional Based on TM4


Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4

Permanent
Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Additional Based on TM4
Additional Based on TM4

Permanent
Permanent
Permanent
Permanent
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

Additional Based on TM4


Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Additional Based on TM4
Project: GSC PHASE 1 (Mechanical RETAIL area)
Location: Ortigas ave., Greenhills, San Juan, Metro Manila
Subject: AHU, FANS and BLOWER MONITORING START-UP & FUNCTIONALITY SCHEDULE
Date: MARCH 22, 2022

Capacity QTY MOTOR RATING


ITEM EQUIPMENT TAGGING
TR KW V Ph Hz
WATER CHILLER
1 WC-1 1,000 1 560 400 3 60
2 WC-2 1,000 1 560 400 3 60
3 WC-3 1,000 1 560 400 3 60
4 WC-4 1,000 1 560 400 3 60
5 WC-5 1,000 1 560 400 3 60
6 WC-6 500 1 280 400 3 60
7 WC-7 500 1 280 230 1 60
Capacity QTY MOTOR RATING
ITEM EQUIPMENT TAGGING
TR HP V Ph Hz
COOLING TOWER
8 CT-1 500 1 25 400 3 60
9 CT-2 500 1 25 400 3 60
10 CT-3 500 1 25 400 3 60
11 CT-4 500 1 25 400 3 60
12 CT-6 500 1 25 400 3 60
13 CT-7 500 1 25 400 3 60
14 CT-8 500 1 25 400 3 60
15 CT-9 500 1 25 400 3 60
16 CT-10 500 1 25 400 3 60
17 CT-11 500 1 25 400 3 60
18 CT-12 500 1 25 400 3 60
Capacity QTY MOTOR RATING
ITEM EQUIPMENT TAGGING
LPS HP V Ph Hz
CHWP AND COWP
19 CHWP-1 151.42 1 100 400 3 60
20 CHWP-2 151.42 1 100 400 3 60
21 CHWP-3 151.42 1 100 400 3 60
22 CHWP-4 151.42 1 100 400 3 60
23 CHWP-5 151.42 1 100 400 3 60
24 CHWP-6 151.42 1 100 400 3 60
25 CHWP-7 75.71 1 60 400 3 60
26 CHWP-8 75.71 1 60 400 3 60
27 COWP-1 189.27 1 100 400 3 60
28 COWP-2 189.27 1 100 400 3 60
29 COWP-3 189.27 1 100 400 3 60
30 COWP-4 189.27 1 100 400 3 60
31 COWP-5 189.27 1 100 400 3 60
32 COWP-6 189.27 1 100 400 3 60
33 COWP-7 94.64 1 50 400 3 60
34 COWP-8 94.64 1 50 400 3 60
Activity

Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test

Activity

Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test

Activity

Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start-up/Functionality Test
Start Date

Start Date

Start Date
End Date Location

Chiller Plant Room


Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room

End Date Location

Chiller Plant Room


Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room

End Date Location

Chiller Plant Room


Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
Chiller Plant Room
REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent

REMARKS

Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Project Name: GH Tower
Subject: Start-up/Functionality Testing Schedule
Note: Based on Updated Schedule
Item No. Activity Floor QTY POWER (KVA)
1 Start-up/Functionality Test Basement 4
Fire Pump 2 150 hp
Jockey Pump 2 7.5 hp

1 Start-up/Functionality Test Roofdeck


Fire Pump 2 60 hp
Jockey Pump 1 3 hp
Note: Based on Updated Schedule
Start Date End Date Required Power Supply

May 9, 2022 May 28, 2022 Permanent


May 9, 2022 May 28, 2022 Permanent

May 9, 2022 May 28, 2022 Permanent


May 9, 2022 May 28, 2022 Permanent
Rating
400V/3Ph/60Hz
400V/3Ph/60Hz

400V/3Ph/60Hz
400V/3Ph/60Hz
Project Name : GH Tower
Subject : Start-up/Testing and Commissioning

Note: Based on Updated Schedule


Item No. Activity Floor QTY
1 Mall Area 1 Escalator
1.1 Well 02 6
1.1.1 ESC 65 HW - GF 1
1.1.2 ESC 66 GF - HW 1
1.1.3 ESC 67 L3 HW - 4F 1
1.1.4 ESC 68 4F - L3 HW 1
1.1.5 ESC 73 4F - 5F 1
1.1.6 ESC 74 5F - 4F 1
1.2 Well 03 8
1.2.1 ESC 21 B2 - B1 1
1.2.2 ESC 22 B1 - B2 1
1.2.3 ESC 23 B1 - LG 1
1.2.4 ESC 24 LG - B1 1
1.2.5 ESC 25 LG - GF 1
1.2.6 ESC 26 GF - LG 1
1.2.7 ESC 71 5F - 6F 1
1.2.8 ESC 72 6F - 5F 1
1.3 Well 04 8
1.3.1 ESC 37 GF - 2F 1
1.3.2 ESC 38 2F - GF 1
1.3.3 ESC 39 2F - 3F 1
1.3.4 ESC 40 3F - 2F 1
1.3.5 ESC 41 3F - 4F 1
1.3.6 ESC 42 4F - 3F 1
1.3.7 ESC 43 4F - 5F 1
1.3.8 ESC 44 5F - 4F 1
1.4 Well 07 2
1.4.1 ESC 63 HW - GF 1
1.4.2 ESC 64 GF - HW 1
1.5 Well 09 4
1.5.1 ESC 69 3F - 4F 1
1.5.1 ESC 70 4F - 3F 1
1.5.1 ESC 75 4F - 5F 1
1.5.1 ESC 76 5F - 4F 1
POWER (kW) Starting Current Rated Current Start Date

7.5 kW 37.0 A 16.5 A Sunday, September 18, 2022


7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022

11 kW 52.0 A 23.0 A Saturday, October 15, 2022


11 kW 52.0 A 23.0 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 78.1 A 35.5 A Saturday, October 15, 2022
9.0 kW 78.1 A 35.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
End Date Required Power Supply Rating

Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz


Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz

Friday, January 27, 2023 Permanent 400V/3Ph/60Hz


Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Project Name : GH Tower
Subject : Start-up/Testing and Commissioning

Note: Based on Updated Schedule


Item No. Activity Floor QTY
1 Mall Area 1 Escalator
1.1 Well 02 6
1.1.1 ESC 65 HW - GF 1
1.1.2 ESC 66 GF - HW 1
1.1.3 ESC 67 L3 HW - 4F 1
1.1.4 ESC 68 4F - L3 HW 1
1.1.5 ESC 73 4F - 5F 1
1.1.6 ESC 74 5F - 4F 1
1.2 Well 03 8
1.2.1 ESC 21 B2 - B1 1
1.2.2 ESC 22 B1 - B2 1
1.2.3 ESC 23 B1 - LG 1
1.2.4 ESC 24 LG - B1 1
1.2.5 ESC 25 LG - GF 1
1.2.6 ESC 26 GF - LG 1
1.2.7 ESC 71 5F - 6F 1
1.2.8 ESC 72 6F - 5F 1
1.3 Well 04 8
1.3.1 ESC 37 GF - 2F 1
1.3.2 ESC 38 2F - GF 1
1.3.3 ESC 39 2F - 3F 1
1.3.4 ESC 40 3F - 2F 1
1.3.5 ESC 41 3F - 4F 1
1.3.6 ESC 42 4F - 3F 1
1.3.7 ESC 43 4F - 5F 1
1.3.8 ESC 44 5F - 4F 1
1.4 Well 07 2
1.4.1 ESC 63 HW - GF 1
1.4.2 ESC 64 GF - HW 1
1.5 Well 09 4
1.5.1 ESC 69 3F - 4F 1
1.5.1 ESC 70 4F - 3F 1
1.5.1 ESC 75 4F - 5F 1
1.5.1 ESC 76 5F - 4F 1
POWER (kW) Starting Current Rated Current Start Date

7.5 kW 37.0 A 16.5 A Sunday, September 18, 2022


7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022
7.5 kW 37.0 A 16.5 A Saturday, October 15, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Friday, November 4, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022

11 kW 52.0 A 23.0 A Saturday, October 15, 2022


11 kW 52.0 A 23.0 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 78.1 A 35.5 A Saturday, October 15, 2022
9.0 kW 78.1 A 35.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022
9.0 kW 43.0 A 19.5 A Saturday, October 15, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022

7.5 kW 37.0 A 16.5 A Friday, November 4, 2022


7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
7.5 kW 37.0 A 16.5 A Friday, November 4, 2022
End Date Required Power Supply Rating

Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz


Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz
Saturday, December 31, 2022 Permanent 400V/3Ph/60Hz

Friday, January 27, 2023 Permanent 400V/3Ph/60Hz


Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz
Friday, January 27, 2023 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz

Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz


Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Thursday, February 16, 2023 Permanent 400V/3Ph/60Hz
Note: Based on Updated Schedule
Item No. Activity Floor QTY

1 Submersible Pump(Elevator) Basement 3 9


2 Submersible Pump(Escalator) Basement 3 2
3 Submersible Pump(Sump Pit)
3.1 Basement 4 2
3.2 Basement 3 9
4 Submersible Pump(Sewage Pit) 3
5 2-CPS Pump Roof Deck 2
6 4-CPS Pump
6.1 Basement 4 2
6.2 Roof Deck 2
7 1-CPS Pump Lower Ground Floor 2
Based on Updated Schedule
POWER (KVA) Start Date End Date Required Power Supply

31-Jan-22 31-Mar-22
31-Jan-22 31-Mar-22

24-Jan-22 2-Jul-22
31-Jan-22 31-Mar-22

31-Jan-22 9-Jul-22

24-Jan-22 2-Jul-22
31-Jan-22 9-Jul-22
31-Jan-22 31-Mar-22
Rating