Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Science made smarter

The Eclipse
Designed to
meet your
every need

AEP, ASSR,
VEMP & OAE testing
on one dedicated
platform

Versions:

EP25 ASSR
- Built for accuracy and speed

EP25 ASSR & VEMP


- Combine the power

EP with VEMP
Balance Solution
- Rate Study and ECochG

EP25 with OAE

Audiometry Tympanometry ABR OAE Hearing Aid Fitting Balance


2
Design your
own diagnostic
solution for a
perfect result Optional
Eclipse Cart
The Eclipse is a modern and Making complicated things easy
offers great
versatile platform. It is designed to A range of pre-loaded test protocols mobility and
fit seamlessly into your everyday are available in each software module organized
workflow and to offer complete ensuring that you will quickly feel
storing
reliability and perfect results. confident. After getting acquainted with
the software you can add or modify
Have it your way test protocols and tailor them to your
The goal: To achieve reliable test specific needs. The clear layouts allow
data to screen or diagnose patients you to easily interpret the results and
accurately and efficiently. focus on the essential outcomes of
the test, which can be saved into the
Whatever your challenge may be, the OtoAccess® database for easy retrieval,
Eclipse hardware platform does just review and export to your EMR.
that, enabling you to focus on the
job at hand with the assistance of A preview of the benefits
dedicated software modules for all - Improved preamplifier - reduces
facets of auditory evoked potentials noise levels up to 25% in ABR/ASSR
and otoacoustic emissions. recordings
- Revolutionary CE-Chirp® stimuli for
Are you future-safe? faster data acquisition
Feedback from audiology experts - Quick and easy waveform editing and
assist in our development process, marking tools
ensuring more effective integration of - Multiple customizable normative data
our software for today and tomorrow. options
Upgrades are available for years to - Convenient pre-loaded test protocols
come. - Simple, direct print to PDF (EMR/EHR
ready) or export to XML


Silence is the Key.
- The Eclipse pre-amplifier provides unrivalled
stealth with very low internal noise

3
Software
modules
for any
challenge

The Eclipse has the largest number
of clinically-relevant features of
any AEP device today. The platform
is an excellent blend of parameter
flexibility and user-friendliness.
Todd B. Sauter  M.A.  Audiology Associates of Worcester  Massachusetts

4 * Stock photo
ABR
EP25
ABR, eABR, MLR, LLR, P300, MMN, ECochG

Database options
ASSR
Threshold assessment

NOAH

or

OtoAccess®

OAE
DPOAE Balance
Screening and clinical DPOAE
VEMP
TEOAE cVEMP
Screening and clinical TEOAE oVEMP

5
Traditional Click

Stimulus

6
The Gold standard
for threshold

Auditory
assessment

Evoked
Potentials
New technologies. For an easier visual evaluation of the NB Fmp – knowing when to stop
New standards. CE-Chirp® responses, each of the NB CE- Imagine having an objective waveform
New ABR. Chirp® stimuli have been time shifted to confidence indicator to assist you in
provide latencies similar to Click and the confirming the presence or absence of
Silence – eliminating the noise CE-Chirp® LS stimulus. The time-shifted a response. The Fmp graph provides
Reducing noise is the single most NB CE-Chirps® are named NB CE-Chirp® objective and mathematical information
important factor for improving any LS, as the placements are level specific. based on multiple points within the
evoked potential recording. The newly recording to assist with your waveform
re-engineered Eclipse preamplifier The CE-Chirp® stimulus family is analysis. Use of the Fmp provides a
reduces that noise by an astonishing incorporated in the ABR and ASSR reduction in test time and confidence in
25%. software modules from Interacoustics. your diagnosis.

CE-Chirp® Stimulus Family – Double Bayesian Weighting saves


your response amplitudes you valuable time
The revolutionary Level Specific CE- Using Bayesian Weighting during your
Chirp® stimulus family for threshold ABR recording ensures that waveforms
assessment (developed by Claus remain stable even during periods of
Elberling) compensates for frequency patient activity. The influence of patient
specific cochlear travel times and noise is minimized during the recording,
generates waveform responses up to resulting in continuously lower noise in The online display of the Fmp serves as a calculated
twice the size of traditional click or tone the running average, saving valuable response confidence. In this example, 99% response
confidence was exceeded after only 1500 sweeps.
burst stimuli. test time.

Rather than testing for a certain number of sweeps,


the residual noise should be used as a stop criteria.

7
EP25
From diagnostic ABR
to specialized AEP
EP25 The benefits of
specialized features

Comprehensive The EP25 incorporates functionality


for early, middle, and late responses,

Clinical AEP including P300 and MNN tests.

For your daily routine


For specialized procedures requiring
- Threshold & neurological ABR testing
the full spectrum of AEPs: Go for the
& eABR
Advanced EP25 software.
- Bayesian weighting
- Residual noise calculator
A new standard
- Fmp calculator
The contemporary interface delivers
- SNR 3:1 ratio calculator
unrivalled ease-of-use and superior
- Normative latency data for click, CE-
clarity, which will help you achieve
Chirp®, NB CE-Chirp®, CE-Chirp® LS & NB
clear and reproducible results in a
CE-Chirp® LS
confident and timely manner. Pre-
- Single/split screen
loaded protocols peer-reviewed by
- CE-Chirp®, NB CE-Chirp®, CE-Chirp® LS &
key-experts, easy tailoring of manual
NB CE-Chirp® LS for optimized
and automatic test protocols and
threshold assessment
a multitude of useful tools make
- CM & ECochG testing
the Eclipse the preferred choice for
- AMLR, ALLR & P300/MMN testing
threshold and neurological ABR.
- ECochG Area Ratio Calculation by
John Ferraro

8
Vestibular EP
– We offer a special
version for the
vestibular clinic with
protocols such as
VEMP, ECochG and
rate study tests

Displaying Right and Left ear in a split screen format Unique ECochG Area Ratio Calculation implementation.
is beneficial when performing threshold work.

9
Automated
VEMP ratio calculation
– The amplitude difference

VEMP between right and left side is


calculated automatically
using the VEMP ratio.
Simply mark two places on
cVEMP
the VEMP curve and
The Cervical Vestibular Evoked
Myogenic Response (cVEMP) is an
the software will calculate
evoked potential measured from the the VEMP ratio.
sternocleidomastoid (SCM) muscle
and is used to test the saccule and its
afferent pathways through the inferior
vestibular nerve.
It is useful in the differential diagnosis
of vestibular system pathology.

oVEMP
The Ocular Vestibular Evoked Myogenic
Potential (oVEMP) is an evoked
potential measured from the inferior
oblique muscle and is used to test
the integrity of the utricle and its
afferent pathways through the superior
vestibular nerve. The oVEMP response
provides information to assist in the
diagnosis of disorders such as Superior
vestibular Neuritis and Superior
Semicircular Canal Dehiscence (SSCD).

Patient Monitor
A correct contraction of the SCM muscle
is essential for a reliable cVEMP
VEMP recording with unequal muscle contraction
recording.
The patient monitor provides
information about the test time and
contraction of the SCM muscle.

EMG Scaling – a reliable result


EMG scaling (amplitude normalization)
corrects for differences in EMG activity
throughout the test allowing for a more
reliable final result.

VEMP ratio - easy calculation


Following VEMP waveform collection,
the right and left waveforms can
easily be set as VEMP partners for an
automated amplitude asymmetry ratio
calculation. VEMP recording with responses scaled according
to muscle tonus during recording

10
Complete system
– Combine VEMP with
the Interacoustics VNG
system for a complete
balance system.

11
ASSR
Where
speed
meets
accuracy
The Interacoustics ASSR system Cut test times in half
reduces test times by 50% thanks The Interacoustics ASSR software uses
to Narrow Band CE-Chirp® stimuli the Narrow Band CE-Chirp® stimuli
and new powerful automated dual to generate a maximal response,
response detection methods. which makes the detection fast and
efficient. The dual detection engine
A new (and faster) generation evaluates both the phase and the
Interacoustics ASSR represents a true response magnitude from twelve
breakthrough and a new generation of the higher harmonics of the
in ASSR threshold estimation. The ASSR fundamental modulation rate. This
software enables 8 frequencies to be patented technology can reduce test
tested simultaneously to threshold in time by 50% compared to traditional
less than 20-30 minutes through the ASSR systems and offers unsurpassed
use of Narrow Band CE-Chirp® stimuli accuracy.
and a patented detection engine.
Save data directly to NOAH
Full control – full speed The estimated audiogram generated by
You will dramatically shorten test time the Interacoustics ASSR can be saved
as you are in full control of selecting to NOAH. The estimated audiogram can
the appropriate stimulus levels easily be transferred to Genie or other
independently for each frequency similar hearing aid fitting software,
based on current and previous ensuring a smooth and accurate
results. Also, you are able to change hearing aid fitting.
the stimulation rate during testing
depending on the state of your patient.
All in all: Full control allows full agility
and speed.

12
13
14
DPOAE20
TEOAE25
Otoacoustic
emissions
The Eclipse hardware platform DPOAE
accommodates both DPOAE and Distortion product emissions
TEOAE capabilities. The DPOAE module produces detailed
DP Grams with protocols designed
Shared features and benefits by the user for their preferences or
- Lightweight probe with low requirements. Confidence in the OAE
internal noise measurements is ensured via DPOAE
- Probe check indicator for correct reliability criteria. Available frequency
placement range is 500-10000 Hz.
- Historic overlay for test comparison
- Test summary providing a quick TEOAE
overview of test results Transient evoked emissions
- Protocol settings for automatic display The TEOAE uses linear or non-linear
of pass/refer results for hearing broad band clicks to evoke otoacoustic
screening emissions. The extensive range of
- Weighted averaging improving data clinical options provide a full clinical
quality and limiting the test time evaluation of TEOAEs. Available
frequency range is 500-5500 Hz.

15
Science Interacoustics USA
10393 West 70th Street

made
Eden Prairie, MN 55344

T +1 800 947 6334


F +1 952 903 4200

smarter info@interacoustics-us.com
interacoustics-us.com

Interacoustics is more than


state-of-the-art solutions

Our mission is clear. We want to lead


the way in audiology and balance by
translating complexity into clarity:
- Challenges made into clear solutions
- Knowledge made practical
- Invisible medical conditions made
tangible and treatable

Our advanced technology and


sophisticated solutions ease the lives of
healthcare professionals.

We will continue to set the standard


for an entire industry. Not for the sake
of science. But for the sake of enabling
professionals to provide excellent
treatment for their millions of patients
across the globe.

Interacoustics-us.com

Go online to
explore our
full product
range

© Interacoustics a/s - 8101801-US - 8 - 02/2020


Related
products
EyeSeeCam Titan OtoRead
Video Head Impulse Test Tympanometry, OAE, Handheld DPOAE & TEOAE
(vHIT) ABRIS and WBT

Product specifications
All technical and hardware specifications concerning all products can be downloaded from our website.

Audiometry Tympanometry ABR OAE Hearing Aid Fitting Balance

You might also like