Test Report issued under the responsibility of:

TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number .............................. : 4788327671
Date of issue ................................... : 2018-04-05
Total number of pages ..................... : 95
Applicant’s name........................... : Cosel Co., Ltd.
Address ........................................... : 1-6-43 Kamiakae-machi, Toyama-shi, Toyama 930-0816, Japan
Test specification:
Standard ........................................... : IEC 62368-1:2014 (Second Edition)
IEC 60065:2014 (Eighth Edition)
IEC 60950-1:2005 (Second Edition) + A1:2009 + A2:2013
Test procedure .................................. : CB Scheme
Non-standard test method ................. : N/A
Test Report Form No. ...................... : IEC62368_1&IEC60065&IEC60950_1A
Test Report Form(s) Originator .......... : UL(US)
Master TRF ....................................... : 2015-06
Copyright © 2015 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.

Test Item description ....................................... : Switching Power Supply


Trade Mark ...................................................... :

Manufacturer ................................................... : Same as applicant


Model/Type reference ...................................... : FETA7000T-48, FETA7000T-144, FETA7000ST-48 and
FETA7000ST-144
Page 2 of 95 Report No. 4788327671

Rating.............................................................. : 200-240Vac 3 PHASE +PE, 50-60Hz, 22.7A (for


FETA7000T-48)
200-240Vac 3 PHASE +PE, 50-60Hz, 23.9A (for
FETA7000T-144)
346-415Y / 200-240VAC 3φ, 50-60Hz, 13.2A (for
FETA7000ST-48)
346-415Y / 200-240VAC 3φ, 50-60Hz, 13.8A (for
FETA7000ST-144)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 3 of 95 Report No. 4788327671

Testing procedure and testing location:


CB Testing Laboratory:
Testing location/ address ................................ : NATOM Corporation
6-10 Higashiohgishima, Kawasaki-ku, Kawasaki-shi
Kanagawa 210-0869, Japan
Associated CB Testing Laboratory:
Testing location/ address ................................. :

Tested by (name, function, signature) .. : Yuji Chikazawa/


Hirokatsu Kubota
Project Handler

Approved by (name, function, signature) : Shinichi Yokoyama/


Ikuro Kinno
Reviewer

Testing procedure: CTF Stage 1


Testing location/ address ................................. :

Tested by (name, function, signature) .. :


Approved by (name, function, signature) :

Testing procedure: CTF Stage 2


Testing location/ address ................................. :

Tested by (name, function, signature) .. :


Witnessed by (name, function, signature)
............................................................ :
Approved by (name, function, signature) :

Testing procedure: CTF Stage 3


Testing procedure: CTF Stage 4
Testing location/ address ................................. :

Tested by (name, function, signature) .. :


Approved by (name, function, signature) :
Supervised by (name, function,
signature):

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 4 of 95 Report No. 4788327671

List of Attachments (including a total number of pages in each attachment):


- European Group Differences and National Differences (3 pages)
- Canada and U.S.A. National Differences (6 pages)
- Enclosures_1: Test Report of IEC 60950-1, Report Reference No.4788327671 (total 136 Pages)
- Enclosures_2: Photographs, Diagrams, Schematics + PWB, Miscellaneous (total 29 pages)
Summary of testing:
Unless otherwise indicated, all tests were conducted at NATOM Corporation, 6-10 Higashiohgishima,
Kawasaki-ku, Kawasaki-shi, Kanagawa, 210-0869 Japan.
Tests performed (name of test and test clause): Testing location:
--
- Classification of electrical energy sources (5.2)
- Temperature measurements
(5.4.1.4, 6.3.2, 9.0, B.2.6)
- Determination of working voltage (5.4.1.8)
- Ball pressure test of thermoplastics (5.4.1.10.3)
- Minimum Clearances/Creepage distance
(5.4.2.2, 5.4.2.4, 5.4.3)
- Minimum Clearances distances using required
withstand voltage (5.4.2.3)
- Electric strength tests (5.4.9)
- Stored discharge on capacitors (5.5.2.2)
- Earthed accessible conductive part (5.7.2.2, 5.7.4)
- Electrical power sources (PS) measurements
for classification (6.2.2)
- Input test (B.2.5)
- Abnormal operating condition tests (B.3)
- Fault condition tests (B.4)
- Limited power source (Q.1)
Summary of compliance with National Differences:
List of countries addressed
Summary of compliance with National Differences (for explanation of codes see below):
Group differences and CA, DK, FI, GB, IT, NO, SE and US.
CA=Canada, DK=Denmark, FI: Finland, GB=United Kingdom, IT=Italy, NO=Norway, SE=Sweden and
US=United States of America.
Group Differences of CENELEC according to the above-mentioned standard and Group Differences are
applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary,
Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
For National Differences see end of this report.
Additionally evaluated Test specifications (see appended test report).
EN 62368-1:2014 Audio/video, information and communication technology equipment Part 1: Safety
requirements.
UL 62368-1:2014 Audio/video, information and communication technology equipment – Part 1: Safety
requirements.
CSA C22.2 NO. 62368-1-14 Audio/video, information and communication technology equipment – Part 1:
Safety requirements.
EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013.
The product fulfils the requirements of IEC 62368-1:2014 (Second Edition).

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 5 of 95 Report No. 4788327671

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be authorized by the
respective NCBs that own these marks.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 6 of 95 Report No. 4788327671

TEST ITEM PARTICULARS:


Classification of use by ............................................... : Ordinary person
Instructed person
Skilled person
Children likely to be present
Supply Connection ..................................................... : AC Mains DC Mains
External Circuit - not Mains connected
- ES1 ES2 ES3
Supply % Tolerance .................................................. : +10%/-10%
+20%/-15%
+____%/ -_____%
None
Supply Connection – Type ......................................... : pluggable equipment type A -
non-detachable supply cord
appliance coupler
direct plug-in
mating connector
pluggable equipment type B -
non-detachable supply cord
appliance coupler
permanent connection
mating connector other: for building-in
Considered current rating of protective device as part of 50A
building or equipment installation ............................... : Installation location: building; equipment
Equipment mobility ..................................................... : movable hand-held transportable
stationary for building-in direct plug-
in rack-mounting wall-mounted
Over voltage category (OVC) ..................................... : OVC I OVC II OVC III
OVC IV other: _______
Class of equipment ................................................... : Class I Class II Class III
Access location ......................................................... : restricted access location N/A
Pollution degree (PD) ................................................ : PD 1 PD 2 PD 3
Manufacturer’s specified maximum operating ambient . : 60 °C. Depends on model and load factor. (See
Enclosure Id. 4-01 and 4-02 for details.)
IP protection class ..................................................... : IPX0 IP___
Power Systems ......................................................... : TN TT IT - 230 V L-L
Altitude during operation (m) ...................................... : 2000 m or less 3000 m or less
Altitude of test laboratory (m) ..................................... : 2000 m or less ______ m
Mass of equipment (kg) ............................................. : Approximately 11 kg

POSSIBLE TEST CASE VERDICTS:


- test case does not apply to the test object ................. : N/A
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................. : F (Fail)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 7 of 95 Report No. 4788327671

TESTING:
Date of receipt of test item .......................................... : 2016-10-24, 2016-11-25, 2017-12-21
Date (s) of performance of tests.................................. : 2016-10-24, 2016-12-06 to 2017-01-13, 2018-01-16 to
2018-02-19, 2018-03-29

GENERAL REMARKS:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

This Test Report covers test results for IEC 62368-1: 2014 (Second Edition), and additional results for IEC
60065: 2014 (Eighth Edition) and/or IEC 60950-1: 2005 (Second Edition) + Am 1: 2009 + Am 2: 2013.

Where a requirement in IEC 62368-1 addresses the same requirement/principle in IEC 60065 and/or IEC
60950-1, compliance with the IEC 62368-1 requirements covers compliance with the same requirement/principle
in IEC 60065 and/or IEC 6095-1, as indicated.

The complete background/rationale behind the considerations in this TRF is outlined in 108/575/INF, IEC TC
108 position related to TRFs associated with the transition of IEC 60065 and IEC 60950-1 to IEC 62368-1. Use
of this TRF is intended to allow for a smooth transition from the legacy standards, IEC 60065 and IEC 60950-1,
to the state-of-art requirements for safety of audio/video, information and communication technology equipment,
IEC 62368-1.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:


The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a declaration Not applicable
from the Manufacturer stating that the sample(s)
submitted for evaluation is (are) representative of the
products from each factory has been provided ............ :
When differences exist; they shall be identified in the General product information section.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 8 of 95 Report No. 4788327671

Name and address of factory (ies) .......................... : 1. Cosel Co., Ltd.


1-6-43 Kamiakae-machi Toyama-shi, Toyama 930-
0816, Japan
2. Cosel Co., Ltd. Tateyama Factory
78 Dogenji, Tateyama Machi Nakaniikawa-gun,
Toyama 930-0241, Japan
3. Eikoku Co., Ltd.
45-6 Nishida Kaneoke, Kokufu-cho Takayama-shi,
Gifu 509-4123, Japan
4. Eikoku Co., Ltd. Toyama Satellite Factory
223 Nakajinzu Yatsuo-Machi, Toyama-shi, Toyama
939-2311, Japan
5. Daiyon Corp.
1-18 Zoushima, Fuchu-machi, Toyama-shi,
Toyama-Ken 939-2726, Japan
6. Kyousei Co., Ltd.
501-1 Nakaookubo Toyama-shi, Toyama-Ken 939-
2243, Japan
7. Takanami Co., Ltd.
2000-39 Hirokami Imizu-shi, Toyama-Ken 939-
0256, Japan
8. Sunrise Industries Co., Ltd.
2-24-6 Terajima, Itoigawa-shi, Niigata 941-0066,
Japan
9. Wuxi Cosel Electronics Co., Ltd
5TH FL, BLD A3, No.866 Liyuan Development
Zone Wuxi Jiangsu 214072 China
10. Glanzhokuriku Co., Ltd.
476 Hashizume machi Hakusan City 924-0812
Japan
11. Futaba Dies Co., Ltd.
762-1 Kunugiyama Nyuzen-machi Shimo Niikawa-
Gun Toyama-Ken 936-0627 JAPAN
Note: The test samples submitted for evaluation are
representative of the products from each factory listed
above.
GENERAL PRODUCT INFORMATION:
Product Description –
The product is a Building-in component type Switching Power Supply.

Model FETA7000T series are intended to be used in end-product which connected to three phase star system
and delta system.

Model FETA7000ST series are intended to be used in end-product which connected to three phase, four wire,
(3/N/PE) system.

This Switching Power Supply unit has three units of CB certified component Power Supply Units (PS1, PS2 and
PS3).

Output ratings:
Model FETA7000T-48 and FETA7000ST-48: 48Vdc (21.6-52.8Vdc), 148.2A, maximum 7113W
Model FETA7000T-144 and FETA7000ST-144: 144Vdc (64.8-158.4Vdc), 52.0A, maximum 7488W

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 9 of 95 Report No. 4788327671

Adjustment of output voltage range was made via component VR31.


AUX output (CN1, CN2 pin1, 2): 12 Vdc, 0.15 A
Condition of output derating: Depends on model, input voltage and ambient temperature. See Enclosure Id. 4-01
and 4-02 for details.
Model Differences –
All models are identical to each other except for output terminal connection of switching power supplies (PS1,
PS2, PS3) output rating and the following AC power distribution systems.

- FETA7000T-48 and FETA7000T-144: Three-phase, three wire, delta system and star system power supply
connection
- FETA7000ST-48 and FETA7000ST-144: Three-phase, four wire, (3/N/PE) system power supply connection

Additional application considerations – (Considerations used to test a component or sub-assembly) –


Additional Information:

Based on attached the IEC 60950-1 informative report (see attached Enclosure 1) and the review of product
construction, only following tests were deemed necessary.
- 5.2: Classification of electrical energy sources
- 5.5.2.2: Capacitor discharge test
- 5.7: Prospective Touch Voltage and Touch Current Measurement

In this Test Report, CENELEC mark license indicating compliance to EN standard was used to verify component
compliance to IEC standard because the standards are technically equivalent.
The Clearances and Creepage Distances have additionally been assessed for suitability up to 3000 m elevation.

Technical Considerations
- The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by
the manufacturer’s specification of: 60°C. (See Enclosure Id. 4-01 and 4-02 for details of output derating
upon the factors including ambient temperature.)

- The product is intended for use on the following power systems: TN

- Models FETA7000T-48 and FETA7000ST-48 were tested with output voltage range of 21.6 – 52.8Vdc
(maximum 7113W), Models FETA7000T-144 and FETA7000ST-144 were tested with output voltage range
of 64.8 – 158.4Vdc (maximum 7488W), Adjustment was made via component VR31.

Engineering Conditions of Acceptability

- The end-product Electric Strength Test shall take into account the maximum working voltage of: Primary-
Ground: 428 Vrms, 976Vpk, Primary-Secondary: 349 Vrms, 1050 Vpk

- The following secondary output circuits are ES1: 48Vdc output of Models FETA7000T-48 and
FETA7000ST-48, and interface circuit (CN1, CN2) of all models.

- The following secondary output circuits are PS2: AUX output

- The following secondary output circuits are PS3: Outputs of all models except for AUX output

- The following secondary output circuits are limited power source: AUX output

- The power supply terminals and/or connectors are: Suitable for factory wiring only

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 10 of 95 Report No. 4788327671

- Proper bonding to the end-product main protective earthing termination is: Required (Chassis or cover)

- An investigation of the protective bonding terminals has: Not been conducted

- The following input connectors must be connected to the end-product supply neutral: TB2 Pin 2 (N) (Indicate
near the TB2 for models FETA7000ST-48 and FETA7000ST-144).

- The following end-product enclosures are required: Electrical, Fire

- This component has been evaluated in ‘control of fire spread’ method assuming appropriate fire enclosure is
provided in end product. Unless the fire enclosure is made of non-combustible or V-0 material, the
separation from the PIS (all electrical components) shall be considered.

- Mains Supply Source is assumed to both Delta system and Star system during the tests for model
FETA7000T-48 and FETA7000T-144.

- Mains Supply Source is assumed to Star system during the tests for model FETA7000ST-48 and
FETA7000ST-144.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 11 of 95 Report No. 4788327671

ENERGY SOURCE IDENTIFICATION AND CLASSIFICATION TABLE:


(Note 1: Identify the following six (6) energy source forms based on the origin of the energy.)
(Note 2: The identified classification e.g., ES2, TS1, should be with respect to its ability to cause pain or injury
on the body or its ability to ignite a combustible material. Any energy source can be declared Class 3 as a worse
case classification e.g. PS3, ES3.
Electrically-caused injury (Clause 5):
(Note: Identify type of source, list sub-assembly or circuit designation and corresponding energy source
classification)
Example: +5 V dc input ES1
Source of electrical energy Corresponding classification (ES)
All circuits except for output of Models FETA7000T-48 and ES3
FETA7000ST-48, AUX output and Interface circuit.
Output of Models FETA7000T-144 and FETA7000ST-144 ES3
Output of Models FETA7000T-48 and FETA7000ST-48 ES1
AUX output ES1
Interface circuit ES1
Electrically-caused fire (Clause 6):
(Note: List sub-assembly or circuit designation and corresponding energy source classification)
Example: Battery pack (maximum 85 watts): PS2
Source of power or PIS Corresponding classification (PS)
All circuits except for AUX output and Interface circuit PS3 (Declared)
AUX output PS2 (Limited Power Source)
Interface circuit PS2
Injury caused by hazardous substances (Clause 7)
(Note: Specify hazardous chemicals, whether produces ozone or other chemical construction not addressed as
part of the component evaluation.)
Example: Liquid in filled component Glycol
Source of hazardous substances Corresponding chemical
N/A N/A
Mechanically-caused injury (Clause 8)
(Note: List moving part(s), fan, special installations, etc. & corresponding MS classification based on Table 35.)
Example: Wall mount unit MS2
Source of kinetic/mechanical energy Corresponding classification (MS)
N/A N/A
Thermal burn injury (Clause 9)
(Note: Identify the surface or support, and corresponding energy source classification based on type of part,
location, operating temperature and contact time in Table 38.)
Example: Hand-held scanner – thermoplastic enclosure TS1
Source of thermal energy Corresponding classification (TS)
N/A (building-in component) N/A
Radiation (Clause 10)
(Note: List the types of radiation present in the product and the corresponding energy source classification.)
Example: DVD – Class 1 Laser Product RS1
Type of radiation Corresponding classification (RS)
N/A N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 12 of 95 Report No. 4788327671

ENERGY SOURCE DIAGRAM


Indicate which energy sources are included in the energy source diagram. Insert diagram below

☐ ES ☐ PS ☐ MS ☐ TS ☐ RS

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 13 of 95 Report No. 4788327671

OVERVIEW OF EMPLOYED SAFEGUARDS


Clause Possible Hazard
5.1 Electrically-caused injury
Body Part Energy Source Safeguards
(e.g. Ordinary) (ES3: Primary Filter circuit)
Basic Supplementary Reinforced
(Enclosure)
Ordinary (assumed to be accessing ES3: All circuits except for N/A N/A Enclosure
end use product) output of Models to be
FETA7000T-48 and provided in
FETA7000ST-48 end
product.
See C of A.
ES3:Primary circuit Clearance Chassis or N/A
and cover to be
creepage bonded to end
distance product
between protective
primary earthing
and terminal. See
Chassis C of A.
and cover
ES3:Primary circuit N/A N/A Y1
capacitors
(C14, C15,
C16) for
Model
FETA7000T
series,
Y1 capacitor
(C15) for
Model
FETA7000S
T series
ES3: Charged energy of N/A N/A Resistors:
X-Capacitors Evaluated in
certified
component
power
supply.
Ordinary (secondary circuit) ES3: All primary circuits N/A N/A Transforme
rs:
Evaluated
in certified
component
power
supply.
N/A N/A Optocoupler
s:
Evaluated in
certified
component
power
supply.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 14 of 95 Report No. 4788327671

N/A N/A Clearance


and
Creepage
distance
6.1 Electrically-caused fire
Material part Energy Source Safeguards
(e.g. mouse enclosure) (PS2: 100 Watt circuit)
Basic Supplementary Reinforced
All electrical components except PS3: Declared Temperat Mounted on N/A
Isolation Transformers (T301, T701) ure in "N" PWB rated V-0
in certified component power and "A" And fire
supply. enclosure to be
provided in end
product. See C
of A
Isolation Transformers (T301, T701) PS3: Declared Temperat Complied with N/A
in certified component power ure in "N" Annex G.5.3.
supply. and "A"
Input Terminal Block (TB1, TB2, PS3: Declared Temperat V-0 (Base) N/A
TB3, TB4) ure in "N" And fire
and "A" enclosure to be
provided in
end-product.
See C of A.
Inductors (L11) for Model PS3: Declared Temperat V-0 (Core N/A
FETA7000T series ure in "N" Case)
and "A" And fire
enclosure to be
provided in
end-product.
See C of A.
Insulation sheet PS3: Declared Temperat V-0 or VTM-0 N/A
ure in "N" And fire
and "A" enclosure to be
provided in
end-product.
See C of A.
Printed wiring board PS3: Declared Temperat V-0 N/A
ure in "N"
and "A"
7.1 Injury caused by hazardous substances
Body Part Energy Source Safeguards
(e.g., skilled) (hazardous material)
Basic Supplementary Reinforced
N/A N/A N/A N/A N/A
8.1 Mechanically-caused injury
Body Part Energy Source Safeguards
(e.g. Ordinary) (MS3:High Pressure
Basic Supplementary Reinforced
Lamp)
(Enclosure)
N/A N/A N/A N/A N/A
9.1 Thermal Burn
Body Part Energy Source Safeguards

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 15 of 95 Report No. 4788327671

(e.g., Ordinary) (TS2) Basic Supplementary Reinforced


N/A N/A N/A N/A N/A
10.1 Radiation
Body Part Energy Source Safeguards
(e.g., Ordinary) (Output from audio port)
Basic Supplementary Reinforced
N/A N/A N/A N/A N/A
Supplementary Information:
(1) See attached energy source diagram for additional details.
(2) “N” – Normal Condition; “A” – Abnormal Condition; “S” Single Fault

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 16 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and Secondary internal wire is accepted P
subassemblies base on compliance with IEC
(IEC 60065, 3.4) & (IEC 60950-1, 1.5.1) 60950-1.

4.1.2 Use of components P


(IEC 60065, 3.4, 14.1) & (IEC 60950-1, 1.5.2)
4.1.3 Equipment design and construction P
(IEC 60065, 3.1) & (IEC 60950-1, 1.3.2)
4.1.15 Markings and instructions ................................ : See Annex F 
(IEC 60065, 5.1) & (IEC 60950-1, 1.7)
4.4.4 Safeguard robustness N/A
4.4.4.2 Steady force tests ........................................... : Building-in component. 
(IEC 60065, 9.1.1.7 c), 13.3.1) & (IEC 60950-1,
4.2.4)
4.4.4.3 Drop tests ....................................................... : Building-in component. 
(IEC 60065, 12.1.5) & (IEC 60950-1, 4.2.6)
4.4.4.4 Impact tests .................................................... : Building-in component. 
(IEC 60065, 12.1.4) & (IEC 60950-1, 4.2.5)
4.4.4.5 Internal accessible safeguard enclosure and Building-in component. 
barrier tests ..................................................... : Assumed all parts are not
(IEC 60950-1, 4.2.3) accessible to end product user.
4.4.4.6 Glass Impact tests ........................................... : Building-in component. 
(IEC 60065, 19.6) & (IEC 60950-1, 4.2.5)
4.4.4.7 Thermoplastic material tests ............................ : Building-in component. 
(IEC 60065, 12.1.6) & (IEC 60950-1, 4.2.7)
4.4.4.8 Air comprising a safeguard .............................. : Building-in component. 
(IEC 60065, 9.1.7) & (IEC 60950-1, 4.2)
4.4.4.9 Accessibility and safeguard effectiveness N/A
(IEC 60065, 9.1.7) & (IEC 60950-1, 4.2.1)
4.5 Explosion No explosion under normal, P
abnormal and single fault condition.
4.6 Fixing of conductors P
(IEC 60065, 8.14) & (IEC 60950-1, 3.1.9)
4.6.1 Fix conductors not to defeat a safeguard Conductors are suitably terminated, P
(IEC 60065, 8.14) & (IEC 60950-1, 3.1.9) creepage and clearances
maintained, second securing for
soldered terminations provided.
4.6.2 10 N force test applied to ................................ : No tests were considered 
(IEC 60065, 8.14) & (IEC 60950-1, 3.1.9) necessary.

4.7 Equipment for direct insertion into mains socket – No such equipment. N/A
outlets
(IEC 60065, 15.4) & (IEC 60950-1, 4.3.6)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 17 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

4.7.2 Mains plug part complies with the relevant 


standard .......................................................... :
(IEC 60065, 15.4.2) & (IEC 60950-1, 4.3.6)
4.7.3 Torque (Nm).................................................... : 
(IEC 60065, 15.4.1) & (IEC 60950-1, 4.3.6)
4.8 Products containing coin/button cell batteries No batteries used. N/A
(IEC 60065, 12.7)
4.8.2 Instructional safeguard N/A
(IEC 60065, 5.4 c), 5.5.2 j))
4.8.3 Battery Compartment Construction N/A
(IEC 60065, 12.7.2)
Means to reduce the possibility of children 
removing the battery........................................ :
4.8.4 Battery Compartment Mechanical Tests .......... : 
(IEC 60065, 12.7.3)
4.8.5 Battery Accessibility N/A
(IEC 60065, 12.7.4)
4.9 Likelihood of fire or shock due to entry of Building-in component. 
conductive object ............................................ :
(IEC 60065, 9.1.3, 20.3.2) & (IEC 60950-1, 4.6.1)

5 ELECTRICALLY-CAUSED INJURY P
5.2.1 Electrical energy source classifications ............. : See appended table 5.2 
5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current ...................... : See appended table 5.2.2.2 
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.2, 2.3, 2.4)
5.2.2.3 Capacitance limits............................................ : See appended table 5.2.2.3 
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.4)
5.2.2.4 Single pulse limits ............................................ : No single pulse. 
(IEC 60950-1, 2.2)
5.2.2.5 Limits for repetitive pulses ................................ : No repetitive pulse. 
(IEC 60950-1, 2.2)
5.2.2.6 Ringing signals ............................................... : No ringing signals. 
(IEC 60950-1, 2.3, Annex M)
5.2.2.7 Audio signals .................................................. : No audio signals. 
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.1.1.9)
5.3 Protection against electrical energy sources P
(IEC 60065, 9.1.1) & (IEC 60950-1, 2.1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 18 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

5.3.1 General Requirements for accessible parts to (for Models FETA7000T-48 and P
ordinary, instructed and skilled persons FETA7000ST-48)
(IEC 60065, 9.1.1) & (IEC 60950-1, 2.1) Secondary ES1 outputs are
assumed to be accessible in end
product application.
5.3.2.1 Accessibility to electrical energy sources and Building-in component. N/A
safeguards Final compliance to be evaluated
(IEC 60065, 9.1.1.3, 9.1.2, 9.1.3, 9.1.4, 9.1.5) & in end-product.
(IEC 60950-1, 2.1.1.1)
5.3.2.2 Contact requirements N/A
(IEC 60065, 9.1.1.1) & (IEC 60950-1, 2.1.1.1)
a) Test with test probe from Annex V ................ : 
b) Electric strength test potential (V) ................. : 
c) Air gap (mm) ............................................... : 
5.3.2.4 Terminals for connecting stripped wire N/A
(IEC 60065, 9.1.1.4)
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material P
(IEC 60065, 8.3) & (IEC 60950-1, 2.9.1)
5.4.1.3 Humidity conditioning ...................................... : See sub-clause 5.4.8 
(IEC 60065, 10.3)
(IEC 60950-1, 2.9.1)
5.4.1.4 Maximum operating temperature for insulating See appended table 5.4.1.4 
materials ......................................................... :
(IEC 60065, 7.1) & (IEC 60950-1, 4.5)
5.4.1.5 Pollution degree............................................... : 2 
(IEC 60065, 13.1) & (IEC 60950-1, 2.10.1.2)
5.4.1.5.2 Test for pollution degree 1 environment and for an No such insulating parts. N/A
insulating compound
(IEC 60065, 13.6, 13.7) & (IEC 60950-1, 2.10.10)
5.4.1.5.3 Thermal cycling N/A
(IEC 60065, 13.6) & (IEC 60950-1, 2.10.9)
5.4.1.6 Insulation in transformers with varying dimensions No such transformer. N/A
(IEC 60065, 13.2) & (IEC 60950-1, 2.10.1.5)
5.4.1.7 Insulation in circuits generating starting pulses No circuits generating starting N/A
(IEC 60950-1, 2.10.3.5) pulses.

5.4.1.8 Determination of working voltage See appended table 5.4.2.2, 5.4.2.4 P


(IEC 60065, 13.2) & (IEC 60950-1, 2.10.2) and 5.4.3

5.4.1.9 Insulating surfaces Building-in component. N/A


(IEC 60065, 13.3.1) & (IEC 60950-1, 2.10.3.1)
5.4.1.10 Thermoplastic parts on which conductive metallic P
parts are directly mounted
(IEC 60065, 7.2) & (IEC 60950-1, 4.5.5)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 19 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

5.4.1.10.2 Vicat softening temperature.............................. : Ball pressure test applied. 


(IEC 60065, 7.2)
5.4.1.10.3 Ball pressure .................................................. : See appended table 5.4.1.10.3 
(IEC 60950-1, 4.5.5)
5.4.2 Clearances P
(IEC 60065, 13.3, Annex J) & (IEC 60950-1,
2.10.3, Annex G)
5.4.2.2 Determining clearance using peak working voltage See appended table 5.4.2.2 P
5.4.2.3 Determining clearance using required withstand See appended table 5.4.2.3 
voltage ........................................................... :
a) a.c. mains transient voltage .......................... : 2500 V 
b) d.c. mains transient voltage ......................... : No connection to the d.c. mains. 
c) external circuit transient voltage .................... : No connection to the external 
circuit.
d) transient voltage determined by measurement Not measured. 
....................................................................... :
5.4.2.4 Determining the adequacy of a clearance using an N/A
electric strength test
5.4.2.5 Multiplication factors for clearances and test Unit intended for use in altitudes up 
voltages........................................................... : to 3000 m.
5.4.3 Creepage distances ......................................... : See appended table 5.4.3. 
(IEC 60065, 13.4) & (IEC 60950-1, 2.10.4)
5.4.3.1 General P
5.4.3.3 Material Group ................................................ : Material group IIIb is assumed to be 
(IEC 60065, 13.4) & (IEC 60950-1, 2.10.4.2) used.

5.4.4 Solid insulation P


(IEC 60065, 8.8) & (IEC 60950-1, 2.10.5)
5.4.4.2 Minimum distance through insulation ............... : See appended table 5.4.4.2 P
(IEC 60065, 8.8) & (IEC 60950-1, 2.10.5.2)
5.4.4.3 Insulation compound forming solid insulation No such insulation. P
(IEC 60065, 13.6, 13.7, 13.8) & (IEC 60950-1,
2.10.5.3)
5.4.4.4 Solid insulation in semiconductor devices Evaluated in certified component N/A
(IEC 60065, 13.6, 13.8) & (IEC 60950-1, 2.10.5.4) power supply.

5.4.4.5 Cemented joints Not considered. N/A


(IEC 60065, 13.6) & (IEC 60950-1, 2.10.5.5)
5.4.4.6 Thin sheet material See appended table 5.4.4.2. P
(IEC 60065, 8.8) & (IEC 60950-1, 2.10.5.6)
5.4.4.6.1 General requirements N/A
(IEC 60065, 8.8)
5.4.4.6.2 Separable thin sheet material See appended table 5.4.4.2. P
(IEC 60065, 8.8) & (IEC 60950-1, 2.10.5.7)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 20 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Number of layers (pcs) ................................... : 


5.4.4.6.3 Non-separable thin sheet material N/A
(IEC 60065, 8.21) & (IEC 60950-1, 2.10.5.8)
5.4.4.6.4 Standard test procedure for non-separable thin 
sheet material ................................................. :
(IEC 60950-1, 2.10.5.9)
5.4.4.6.5 Mandrel test N/A
(IEC 60065, 8.21) & (IEC 60950-1, Annex AA)
5.4.4.7 Solid insulation in wound components Evaluated in certified component N/A
(IEC 60065, 8.16) & (IEC 60950-1, 2.10.5.11) power supply.

5.4.4.9 Solid insulation at frequencies >30 kHz ........... : See appended Table 5.4.4.9 
5.4.5 Antenna terminal insulation No antenna terminal. N/A
(IEC 60065, 10.2) & (IEC 60950-1, 7.4)
5.4.5.1 General N/A
5.4.5.2 Voltage surge test N/A
(IEC 60065, 10.2) & (IEC 60950-1, 7.4.2)
Insulation resistance (M)............................... : 
5.4.6 Insulation of internal wire as part of No such internal wire. 
supplementary safeguard ................................ :
(IEC 60065, 8.9) & (IEC 60950-1, 2.1.1.3)
5.4.7 Tests for semiconductor components and for N/A
cemented joints
(IEC 60065, 13.6, 13.7, 13.8) & (IEC 60950-1,
2.10.11)
5.4.8 Humidity conditioning P
(IEC 60065, 10.3) & (IEC 60950-1, 2.9.2)
Relative humidity (%) ...................................... : 93 % 
Temperature (°C) ........................................... : 25 °C 
Duration (h) .................................................... : 48 hours 
5.4.9 Electric strength test ........................................ : See appended table 5.4.9 
(IEC 60065, 10.4) & (IEC 60950-1, 5.2)
5.4.9.1 Test procedure for a solid insulation type test P
(IEC 60065, 10.4) & (IEC 60950-1, 5.2)
5.4.9.2 Test procedure for routine tests N/A
(IEC 60065, N.3.2) & (IEC 60950-1, 5.2.2)
5.4.10 Protection against transient voltages between Building-in component. N/A
external circuit No connection to such external
(IEC 60065, Annex B) & (IEC 60950-1, 6.2) circuit.
5.4.10.1 Parts and circuits separated from external circuits N/A
(IEC 60950-1, 6.2.1)
5.4.10.2 Test methods N/A
(IEC 60950-1, 6.2.2)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 21 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

5.4.10.2.1 General N/A


5.4.10.2.2 Impulse test .................................................... : 
(IEC 60950-1, 6.2.2.1)
5.4.10.2.3 Steady-state test ............................................. : 
(IEC 60950-1, 6.2.2.2)
5.4.11 Insulation between external circuits and earthed Building-in component. 
circuitry ........................................................... : No connection to such external
(IEC 60065, Annex B) & (IEC 60950-1, 6.1) circuit.
5.4.11.1 Exceptions to separation between external N/A
circuits and earth
(IEC 60950-1, 6.1.2.2)
5.4.11.2 Requirements N/A
(IEC 60950-1, 6.1.2.1)
Rated operating voltage Uop (V) ....................... : 
Nominal voltage Upeak (V)................................. : 
Max increase due to variation Usp .................... : 
Max increase due to ageing Usa .................... : 
Uop= Upeak +  Usp + Usa .................................. : 
5.5 Components as safeguards P
5.5.1 General P
5.5.2 Capacitors and RC units P
(IEC 60065, 14.3)
5.5.2.1 General requirement Type X2 capacitors are used P
(IEC 60065, 14.3) & (IEC 60950-1, 1.5.6) between lines, type Y1 capacitors
are used between line and earth
comply with IEC 60384-14 (for
model FETA7000T series).
Type Y1 capacitors are used
between Neutral and FG comply
with IEC 60384-14 (for model
FETA7000ST series).
See appended table 4.1.2.
5.5.2.2 Safeguards against capacitor discharge after See appended table 5.5.2.2 
disconnection of a connector ........................... :
(IEC 60065, 9.1.6) & (IEC 60950-1, 2.1.1.7)
5.5.3 Transformers See Annex G.5.3 P
(IEC 60065, 14.4) & (IEC 60950-1, 1.5.4, Annex C)
5.5.4 Optocouplers Evaluated in certified component N/A
(IEC 60065, 14.12) & (IEC 60950-1, 2.10.5.3, power supply.
2.10.5.4)
5.5.5 Relays No relay used. N/A
5.5.6 Resistors Evaluated in certified component N/A
(IEC 60065, 14.2) & (IEC 60950-1, 1.5.7) power supply.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 22 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

5.5.7 SPD’s No such components. N/A


(IEC 60065, 14.13) & (IEC 60950-1, 1.5.9)
5.5.7.1 Use of an SPD connected to reliable earthing N/A
(IEC 60065, 14.13) & (IEC 60950-1, 1.5.9.4)
5.5.7.2 Use of an SPD between mains and protective N/A
earth
(IEC 60065, 14.13) & (IEC 60950-1, 1.5.9.4)
5.5.8 Insulation between the mains and external circuit No external circuit. 
consisting of a coaxial cable ............................ :
(IEC 60065, 10.2) & (IEC 60950-1, 1.5.7.3, 7.4)
5.6 Protective conductor N/A
5.6.2 Requirement for protective conductors N/A
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3, 2.6.5)
5.6.2.1 General requirements Building-in component. Final N/A
compliance to be evaluated in end-
product. Chassis or cover
considered to be connected to the
end-product bonding.
5.6.2.2 Colour of insulation No such conductors. N/A
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3.5)
5.6.3 Requirement for protective earthing conductors No power cords provided. N/A
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3.2)
Protective earthing conductor size (mm2) ........... : 
5.6.4 Requirement for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
(IEC 60950-1, 2.6.3.3)
Protective bonding conductor size (mm2). ........... : 
Protective current rating (A) ............................. : 
5.6.4.3 Current limiting and overcurrent protective N/A
devices
(IEC 60950-1, 2.6.5.2)
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Requirement Building-in component. N/A
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.4.2) To be evaluated in end-product.
Proper bonding to the end-product
main protective earthing termination
is from Chassis or cover.
Conductor size (mm2), nominal thread diameter 
(mm). ................................................................ :
5.6.5.2 Corrosion See Annex N. Final compliance is N/A
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.5.6) to be evaluated for the end product.

5.6.6 Resistance of the protective system <Reference only> N/A


(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3.4) See appended table 5.6.6.2

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 23 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

5.6.6.1 Requirements N/A


(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3.4)
5.6.6.2 Test Method Resistance () .............................. : 
(IEC 60065, 15.2) & (IEC 60950-1, 2.6.3.4)
5.6.7 Reliable earthing Building-in component. N/A
(IEC 60065, 14.13) & (IEC 60950-1, 1.5.9.4,
5.1.7.1)
5.7 Prospective touch voltage, touch current and protective conductor current P
5.7.2 Measuring devices and networks P
5.7.2.1 Measurement of touch current ........................... : FG terminal is assumed to be 
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 5.1.4) connected to Accessible parts in
end-product.
See appended table 5.7.2.2, 5.7.4
5.7.2.2 Measurement of prospective touch voltage P
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 1.4.9)
5.7.3 Equipment set-up, supply connections and earth P
connections
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 5.1.3)
System of interconnected equipment (separate No such component. 
connections/single connection) .......................... :
Multiple connections to mains (one connection at No such component. 
a time/simultaneous connections) ...................... :
5.7.4 Earthed conductive accessible parts.................. : Building-in component. N/A
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 5.1.6) No accessible parts.
5.7.5 Protective conductor current Building-in component. N/A
(IEC 60950-1, 5.1.7) No protective conductor.
Supply Voltage (V) ............................................ : 
Measured current (mA)...................................... : 
Instructional Safeguard...................................... : 
5.7.6 Prospective touch voltage and touch current due No connection to the external N/A
to external circuits circuit.
(IEC 60950-1, 5.1.8)
5.7.6.1 Touch current from coaxial cables No connection to the coaxial cable. N/A
5.7.6.2 Prospective touch voltage and touch current from N/A
external circuits
(IEC 60950-1, 5.1.8.1)
5.7.7 Summation of touch currents from external N/A
circuits
(IEC 60950-1, 5.1.8.2)
a) Equipment with earthed external circuits 
Measured current (mA)...................................... :
b) Equipment whose external circuits are not 
referenced to earth. Measured current (mA) ...... :

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 24 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

6 ELECTRICALLY- CAUSED FIRE P


6.2 Classification of power sources (PS) and potential ignition sources (PIS) P
6.2.2 Power source circuit classifications P
6.2.2.1 General P
6.2.2.2 Power measurement for worst-case load fault ... : See appended table 6.2.2 
(IEC 60065, 4.3.1) & (IEC 60950-1, 2.5)
6.2.2.3 Power measurement for worst-case power source See appended table 6.2.2 
fault ................................................................. :
(IEC 60065, 4.3.1) & (IEC 60950-1, 2.5)
6.2.2.4 PS1 ................................................................ : No PS1 circuits 
6.2.2.5 PS2 ................................................................ : AUX output and Interface circuit. 
6.2.2.6 PS3 ................................................................ : All circuits except for AUX output 
and Interface circuit.
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ....................................................... : Primary circuit (L-N) conductors to 
be considered arcing PIS.
All circuits are considered arcing
PIS except for output terminal and
secondary connectors.
Arcing PIS is covered with metal
chassis.
6.2.3.2 Resistive PIS ................................................... : All components are considered 
resistive PIS.
6.3 Safeguards against fire under normal operating and abnormal operating conditions P
6.3.1 (a) No ignition and attainable temperature value less See appended table 5.4.1.5, 6.3.2, 
than 90 % defined by ISO 871 or less than 300 C 9.0, B.2.6
for unknown materials ...................................... :
(IEC 60065, 7.1) & (IEC 60950-1, 4.5.3)
6.3.1 (b) Combustible materials outside fire enclosure Building-in component. N/A
(IEC 60950-1, 4.7.3.3)
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method “Control fire spread” applied. P
(IEC 60950-1, 4.7.1)
6.4.2 Reduction of the likelihood of ignition under single N/A
fault conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single N/A
fault conditions in PS2 and PS3 circuits
(IEC 60065, 11.2, 20.2)
6.4.3.1 General N/A
6.4.3.2 Supplementary Safeguards N/A
(IEC 60065, 20.2)
Special conditions if conductors on printed boards N/A
are opened or peeled

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 25 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

6.4.3.3 Single Fault Conditions ..................................... : 


(IEC 60065, 11.2)
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits . N/A
6.4.5 Control of fire spread in PS2 circuits AUX output meets the requirements P
(IEC 60950-1, 4.7.3.4) of Annex Q (Limited Power Source)

6.4.5.2 Supplementary safeguards ............................. : (See appended tables 4.1.2 and 


(IEC 60950-1, 4.7.3.4) Annex G)
All electrical components are
mounted on minimum V-1 printed
wiring board.
6.4.6 Control of fire spread in PS3 circuit Building-in component. N/A
(IEC 60950-1, 4.7.3.4) Fire enclosure shall be provided in
end-product.
6.4.7 Separation of combustible materials from a PIS “Control fire spread” applied. P
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.7.3.4) Insulation sheet between PWB and
Chassis is made of V-0 or VTM-0.
6.4.7.1 General ........................................................... : 
6.4.7.2 Separation by distance N/A
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.7.3.4)
6.4.7.3 Separation by a fire barrier N/A
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.7.3.4)
6.4.8 Fire enclosures and fire barriers Building-in component. N/A
(IEC 60065, 20.2.5, 20.3) & (IEC 60950-1, 4.7.2, Fire enclosure shall be provided in
4.7.3) end-product.
6.4.8.1 Fire enclosure and fire barrier material properties N/A
(IEC 60065, 20.2.5, 20.3) & (IEC 60950-1, 4.7.3.2,
4.7.3.4)
6.4.8.2.1 Requirements for a fire barrier N/A
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.7.3.4)
6.4.8.2.2 Requirements for a fire enclosure N/A
(IEC 60065, 20.3) & (IEC 60950-1, 4.7.3.2)
6.4.8.3 Constructional requirements for a fire enclosure N/A
and a fire barrier
6.4.8.3.1 Fire enclosure and fire barrier openings N/A
(IEC 60065, 20.3) & (IEC 60950-1, 4.6.1, 4.6.2)
6.4.8.3.2 Fire barrier dimensions N/A
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.6.2)
6.4.8.3.3 Top Openings in Fire Enclosure: dimensions 
(mm) ................................................................. :
(IEC 60065, 20.3) & (IEC 60950-1, 4.6.1)
Needle Flame test N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 26 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

6.4.8.3.4 Bottom Openings in Fire Enclosure, condition met 


a), b) and/or c) dimensions (mm) ....................... :
(IEC 60065, 20.3) & (IEC 60950-1, 4.6.2)
Flammability tests for the bottom of a fire 
enclosure .......................................................... :
6.4.8.3.5 Integrity of the fire enclosure, condition met: a), 
b) or c) ............................................................. :
(IEC 60950-1, 4.6.3)
6.4.8.4 Separation of PIS from fire enclosure and fire 
barrier distance (mm) or flammability rating ........ :
(IEC 60065, 20.2.5) & (IEC 60950-1, 4.7.3.1,
4.7.3.2)
6.5 Internal and external wiring N/A
6.5.1 Requirements See 4.1.1 for secondary internal N/A
(IEC 60065, 16.3, 20.2.3) & (IEC 60950-1, 4.7.3.3, wire.
4.7.3.4)
6.5.2 Cross-sectional area (mm2) ............................... : 
6.5.3 Requirements for interconnection to building Building-in component. 
wiring .................................................................. : No such wiring.
(IEC 60950-1, 2.5, 6.3)
6.6 Safeguards against fire due to connection to Building-in component. N/A
additional equipment
(IEC 60950-1, 3.5.4)
External port limited to PS2 or complies with N/A
Clause Q.1

7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A


7.2 Reduction of exposure to hazardous substances No hazardous substances. N/A
7.3 Ozone exposure N/A
(IEC 60950-1, 1.7.2.6)
7.4 Use of personal safeguards (PPE) N/A
Personal safeguards and instructions ................ : 
7.5 Use of instructional safeguards and instructions N/A
Instructional safeguard (ISO 7010) .................... : 
7.6 Batteries............................................................ : No batteries used. 
(IEC 60065, 14.10) & (IEC 60950-1, 4.3.8)

8 MECHANICALLY-CAUSED INJURY N/A


8.1 General N/A
8.2 Mechanical energy source classifications No mechanical energy source. N/A
8.3 Safeguards against mechanical energy sources N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 27 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

8.4 Safeguards against parts with sharp edges and N/A


corners
(IEC 60065, 19.5) & (IEC 60950-1, 4.3.1)
8.4.1 Safeguards N/A
(IEC 60950-1, 4.3.1)
8.5 Safeguards against moving parts N/A
8.5.1 MS2 or MS3 part required to be accessible for the N/A
function of the equipment
(IEC 60065, 14.10.3) & (IEC 60950-1, 4.4)
8.5.2 Instructional Safeguard .................................... : 
(IEC 60950-1, 4.4.5.2)
8.5.4 Special categories of equipment comprising N/A
moving parts
8.5.4.1 Large data storage equipment N/A
(IEC 60950-23)
8.5.4.2 Equipment having electromechanical device for N/A
destruction of media
(IEC 60950-1, Annex EE)
8.5.4.2.1 Safeguards and Safety Interlocks .......................: 
(IEC 60950-1, EE.3)
8.5.4.2.2 Instructional safeguards against moving parts N/A
Instructional Safeguard ......................................: 
(IEC 60950-1, EE.2)
8.5.4.2.3 Disconnection from the supply N/A
(IEC 60950-1, EE.4)
8.5.4.2.4 Probe type and force (N) ....................................: 
(IEC 60950-1, EE.5)
8.5.5 High Pressure Lamps N/A
(IEC 60950-1, 4.2.9)
8.5.5.1 Energy Source Classification N/A
8.5.5.2 High Pressure Lamp Explosion Test ...................: 
8.6 Stability Building-in component. N/A
(IEC 60065, 19) & (IEC 60950-1, 4.1)
8.6.1 Product classification N/A
Instructional Safeguard ......................................: 
(IEC 60065, 5.5.2)
8.6.2 Static stability N/A
(IEC 60065, 19.1) & (IEC 60950-1, 4.1)
8.6.2.2 Static stability test N/A
(IEC 60065, 19.2) & (IEC 60950-1, 4.1)
Applied Force ..................................................... : 

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 28 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

8.6.2.3 Downward Force Test N/A


(IEC 60065, 19.3) & (IEC 60950-1, 4.1)
8.6.3 Relocation stability test N/A
(IEC 60065, 19.2)
Unit configuration during 10 tilt ........................... : 
8.6.4 Glass slide test N/A
8.6.5 Horizontal force test (Applied Force) .................... : 
(IEC 60065, 19.4)
Position of feet or movable parts.......................... : 
8.7 Equipment mounted to wall or ceiling N/A
(IEC 60065, 19.7) & (IEC 60950-1, 4.2.10)
8.7.1 Mounting Means (Length of screws (mm) and 
mounting surface) .............................................. :
(IEC 60065, 19.7)
8.7.2 Direction and applied force .................................. : 
(IEC 60065, 19.7) & (IEC 60950-1, 4.2.10)
8.8 Handles strength N/A
8.8.1 Classification N/A
8.8.2 Applied Force .................................................... : 
8.9 Wheels or casters attachment requirements N/A
8.9.1 Classification N/A
8.9.2 Applied force ...................................................... : 
8.10 Carts, stands and similar carriers N/A
8.10.1 General N/A
8.10.2 Marking and instructions N/A
Instructional Safeguard ....................................... : 
8.10.3 Cart, stand or carrier loading test and compliance N/A
Applied force ...................................................... : 
8.10.4 Cart, stand or carrier impact test N/A
8.10.5 Mechanical stability N/A
Applied horizontal force (N) ................................. : 
8.10.6 Thermoplastic temperature stability (C) .............. : 
8.11 Mounting means for rack mounted equipment N/A
(IEC 60950-1, Annex DD)
8.11.1 General N/A
(IEC 60950-1, DD.1)
8.11.2 Product Classification N/A
8.11.3 Mechanical strength test, variable N ..................: 
(IEC 60950-1, DD.2)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 29 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

8.11.4 Mechanical strength test 250N, including end stops N/A


(IEC 60950-1, DD.3)
8.12 Telescoping or rod antennas ..............................: 
(IEC 60065, 12.6)
Button/Ball diameter (mm) ..................................: 

9 THERMAL BURN INJURY N/A


9.2 Thermal energy source classifications Building-in component. N/A
(IEC 60065, 7.1, 11.2) & (IEC 60950-1, 4.5.4)
9.3 Safeguard against thermal energy sources N/A
(IEC 60065, 7.1, 11.2) & (IEC 60950-1, 4.5.4)
9.4 Requirements for safeguards N/A
9.4.1 Equipment safeguard N/A
(IEC 60065, 7.1, 11.2) & (IEC 60950-1, 4.5.4)
9.4.2 Instructional safeguard ....................................... : 
(IEC 60065, 7.1, 11.2) & (IEC 60950-1, 4.5.4)

10 RADIATION N/A
10.2 Radiation energy source classification No radiation energy source as N/A
specified in this standard is present.
10.2.1 General classification N/A
10.3 Protection against laser radiation No laser. N/A
(IEC 60065, 6.2) & (IEC 60950-1, 4.3.13.5.1)
Laser radiation that exists equipment .................: 
Normal, abnormal, single-fault ...........................: 
Instructional safeguard ......................................: 
Tool...................................................................: 
10.4 Protection against visible, infrared, and UV No UV radiation. N/A
radiation
(IEC 60065, 6.3) & (IEC 60950-1, 4.3.13.4,
4.3.13.5.2)
10.4.1 General N/A
10.4.1.a) RS3 for Ordinary and instructed persons ...........: 
10.4.1.b) RS3 accessible to a skilled person ....................: 
Personal safeguard (PPE) instructional safeguard 
.........................................................................:
10.4.1.c) Equipment visible, IR, UV does not exceed RS1 : 
10.4.1.d) Normal, abnormal, single-fault conditions .........: 
10.4.1.e) Enclosure material employed as safeguard is 
opaque ..............................................................:

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 30 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

10.4.1.f) UV attenuation ..................................................: 


10.4.1.g) Materials resistant to degradation UV ................: 
10.4.1.h) Enclosure containment of optical radiation .........: 
10.4.1.i) Exempt Group under normal operating conditions 
.........................................................................:
10.4.2 Instructional safeguard ......................................: 
10.5 Protection against x-radiation No x-radiation. N/A
(IEC 60065, 6.1) & (IEC 60950-1, 4.3.13.2)
10.5.1 X- radiation energy source that exists equipment : 
Normal, abnormal, single fault conditions N/A
Equipment safeguards.......................................: 
Instructional safeguard for skilled person ...........: 
10.5.3 Most unfavourable supply voltage to give 
maximum radiation ............................................:
(IEC 60950-1, Annex H)
Abnormal and single-fault condition ...................: 
Maximum radiation (pA/kg) ................................: 
10.6 Protection against acoustic energy sources No acoustic energy sources. N/A
10.6.1 General N/A
10.6.2 Classification N/A
Acoustic output, dB(A) .......................................: 
Output voltage, unweighted r.m.s. .....................: 
10.6.4 Protection of persons N/A
Instructional safeguards ....................................: 
Equipment safeguard prevent ordinary person to 
RS2...................................................................:
Means to actively inform user of increase sound 
pressure ............................................................:
Equipment safeguard prevent ordinary person to 
RS2...................................................................:
10.6.5 Requirements for listening devices (headphones, N/A
earphones, etc.)
10.6.5.1 Corded passive listening devices with analogue N/A
input
Input voltage with 94 dB(A) LAeq acoustic 
pressure output .................................................:
10.6.5.2 Corded listening devices with digital input N/A
Maximum dB(A) ................................................: 
10.6.5.3 Cordless listening device N/A
Maximum dB(A) ................................................: 

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 31 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

B NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING P


CONDITION TESTS AND SINGLE FAULT CONDITION TESTS
B.2 Normal Operating Conditions P
B.2.1 General requirements........................................ : See Test Item Particulars and 
(IEC 60065, 4.2.1) & (IEC 60950-1, 1.4.4) appended test tables

Audio Amplifiers and equipment with audio No audio amplifier. 


amplifiers .......................................................... :
(IEC 60065, 4.2.5) & (IEC 60950-1, 4.4)
B.2.3 Supply voltage and tolerances +10 % / -10 % P
(IEC 60065, 4.2.2) & (IEC 60950-1, 1.4.5)
B.2.5 Input test ........................................................... : See appended table B.2.5 
(IEC 60065, 4.2, 5.2 g), h)) & (IEC 60950-1, 1.6.2)
B.3 Simulated abnormal operating conditions P
B.3.1 General requirements........................................ : See appended table B.3 
(IEC 60065, 4.3) & (IEC 60950-1, 5.3.1)
B.3.2 Covering of ventilation openings Building-in component. N/A
(IEC 60065, 4.3.11) & (IEC 60950-1, 5.3.1)
B.3.3 D.C. mains polarity test No connection to the D.C. mains. N/A
(IEC 60065, 4.2.2) & (IEC 60950-1, 5.3.1)
B.3.4 Setting of voltage selector ................................. : No voltage selector. 
(IEC 60065, 4.3.14) & (IEC 60950-1, 5.3.1)
B.3.5 Maximum load at output terminals ...................... : See appended table B.3. 
(IEC 60065, 4.3.10) & (IEC 60950-1, 5.3.7)
B.3.6 Reverse battery polarity No battery. N/A
(IEC 60065, 4.3.12) & (IEC 60950-1, 4.3.8)
B.3.7 Abnormal operating conditions as specified in No audio amplifier. N/A
Clause E.2.
(IEC 60065, 4.3.6) & (IEC 60950-1, 5.3.6)
B.3.8 Safeguards functional during and after abnormal See appended table B.4. P
operating conditions
(IEC 60065, 11) & (IEC 60950-1, 5.3.9)
B.4 Simulated single fault conditions P
(IEC 60065, 4.3) & (IEC 60950-1, 1.4.14)
B.4.2 Temperature controlling device open or short- See appended table B.4 
circuited ............................................................ :
B.4.3 Motor tests P
(IEC 60065, 4.3.7) & (IEC 60950-1, 5.3.2)
B.4.3.1 Motor blocked or rotor locked increasing the See appended table B.4 
internal ambient temperature ............................ :
(IEC 60065, 4.3.7) & (IEC 60950-1, 5.3.2)
B.4.4 Short circuit of functional insulation See appended table B.4 P
(IEC 60950-1, 5.3.4)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 32 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

B.4.4.1 Short circuit of clearances for functional insulation See appended table B.4 P
B.4.4.2 Short circuit of creepage distances for functional See appended table B.4 P
insulation
B.4.4.3 Short circuit of functional insulation on coated No coated printed board. N/A
printed boards
B.4.5 Short circuit and interruption of electrodes in See appended table B.4 P
tubes and semiconductors
(IEC 60065, 4.3.4) & (IEC 60950-1, 5.3.7)
B.4.6 Short circuit or disconnect of passive components See appended table B.4 P
(IEC 60065, 4.3.5) & (IEC 60950-1, 5.3.7)
B.4.7 Continuous operation of components No applicable component. N/A
(IEC 60065, 4.3.8) & (IEC 60950-1, 5.3.5)
B.4.8 Class 1 and Class 2 energy sources within limits See appended table B.4 P
during and after single fault conditions
(IEC 60065, 11) & (IEC 60950-1, 5.3.9)
B.4.9 Battery charging under single fault conditions .... : No battery. N/A
(IEC 60065, 14.11.3) & (IEC 60950-1, 4.3.8)

C UV RADIATION N/A
C.1 Protection of materials in equipment from UV No ultraviolet light source. N/A
radiation
(IEC 60950-1, 4.3.13.3)
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
(IEC 60950-1, Annex Y)
C.2.1 Test apparatus N/A
(IEC 60950-1, Y.1)
C.2.2 Mounting of test samples N/A
(IEC 60950-1, Y.2)
C.2.3 Carbon-arc light-exposure apparatus N/A
(IEC 60950-1, Y.3)
C.2.4 Xenon-arc light exposure apparatus N/A
(IEC 60950-1, Y.4)

D TEST GENERATORS N/A


D.1 Impulse test generators Not used. N/A
(IEC 60065, Annex K) & (IEC 60950-1, N.1)
D.2 Antenna interface test generator N/A
(IEC 60950-1, N.2)
D.3 Electronic pulse generator N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 33 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

E TEST CONDITIONS FOR EQUIPMENT CONTAINING AUDIO AMPLIFIERS N/A


E.1 Audio amplifier normal operating conditions No audio amplifier. N/A
(IEC 60065, 4.2.5) & (IEC 60950-1, 4.5.1)
Audio signal voltage (V)..................................... : 
Rated load impedance (Ω) ................................ : 
E.2 Audio amplifier abnormal operating conditions N/A
(IEC 60065, 4.3.6) & (IEC 60950-1, 5.3.6)

F EQUIPMENT MARKINGS, INSTRUCTIONS, AND INSTRUCTIONAL SAFEGUARDS P


F.1 General requirements P
(IEC 60065, 5.1, 5.2, 5.3) & (IEC 60950-1, 1.7.2.1)
Instructions – Language ................................... : English version checked. 
F.2 Letter symbols and graphical symbols P
(IEC 60065, 5.1)
F.2.1 Letter symbols according to IEC60027-1 N/A
(IEC 60065, 5.1)
F.2.2 Graphic symbols IEC, ISO or manufacturer P
specific
(IEC 60065, 5.1) & (IEC 60950-1, 1.7.1.1)
F.3 Equipment markings P
F.3.1 Equipment marking locations Building-in component. N/A
(IEC 60065, 5.1) & (IEC 60950-1, 1.7.1.2)
F.3.2 Equipment identification markings Manufacturer identification logo P
(IEC 60065, 5.2) & (IEC 60950-1, 1.7.1.2) mark is marked on nameplate.
See clause F.3.2.1.
F.3.2.1 Manufacturer identification ................................ : 
(IEC 60065, 5.2 a)) & (IEC 60950-1, 1.7.1.2)
F.3.2.2 Model identification ........................................... : Model identification is marked on 
(IEC 60065, 5.2 b)) & (IEC 60950-1, 1.7.1.2) nameplate.

F.3.3 Equipment rating markings Building-in component. N/A


(IEC 60065, 5.2) & (IEC 60950-1, 1.7.1.1) No power rating marking required.
However, marked on the label
correctly.
F.3.3.1 Equipment with direct connection to mains N/A
(IEC 60065, 5.2 e)) & (IEC 60950-1, 1.7.1.1)
F.3.3.2 Equipment without direct connection to mains N/A
(IEC 60065, 5.2 e)) & (IEC 60950-1, 1.7.1.1)
F.3.3.3 Nature of supply voltage .................................... : 
(IEC 60065, 5.2 d)) & (IEC 60950-1, 1.7.1.1)
F.3.3.4 Rated voltage .................................................... : 
(IEC 60065, 5.2 e)) & (IEC 60950-1, 1.7.1.1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 34 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

F.3.3.4 Rated frequency ................................................ : 


(IEC 60065, 5.2 f)) & (IEC 60950-1, 1.7.1.1)
F.3.3.6 Rated current or rated power ............................. : 
(IEC 60065, 5.2 g), h)) & (IEC 60950-1, 1.7.1.1)
F.3.3.7 Equipment with multiple supply connections No such connection. N/A
(IEC 60950-1, 1.7.1.1)
F.3.4 Voltage setting device No such device. N/A
(IEC 60065, 5.2 e)) & (IEC 60950-1, 1.7.4)
F.3.5 Terminals and operating devices P
F.3.5.1 Mains appliance outlet and socket-outlet No such outlet. 
markings ........................................................... :
(IEC 60065, 5.3 c)) & (IEC 60950-1, 1.7.5)
F.3.5.2 Switch position identification marking ................ : No switch used. 
(IEC 60065, 5.5.3) & (IEC 60950-1, 1.7.8.3)
F.3.5.3 Replacement fuse identification and rating Evaluated in certified component 
markings ........................................................... : power supply.
(IEC 60065, 14.6.3.2) & (IEC 60950-1, 1.7.6)
F.3.5.4 Replacement battery identification marking........ : No battery. 
(IEC 60065, 5.5.2 c)) & (IEC 60950-1, 1.7.13)
F.3.5.5 Terminal marking location Terminal marking are located on P
(IEC 60950-1, 1.7.7.1) cover near input terminal.

F.3.6 Equipment markings related to equipment P


classification
F.3.6.1 Class I Equipment P
F.3.6.1.1 Protective earthing conductor terminal Protective Earthing terminal is not N/A
(IEC 60065, 5.3 a)) & (IEC 60950-1, 1.7.7.1) provided on the unit.

F.3.6.1.2 Neutral conductor terminal Primary input connector; “N” P


(IEC 60950-1, 1.7.7.2) marked on cover near input
terminal TB2 (for models
FETA7000ST-48 and
FETA7000ST-144).
F.3.6.1.3 Protective bonding conductor terminals Bonding symbol (IEC 60417-5017) P
(IEC 60950-1, 1.7.7.1) marked on cover near the FG
terminal.
F.3.6.2 Class II equipment (IEC60417-5172) N/A
F.3.6.2.1 Class II equipment with or without functional earth N/A
(IEC 60065, 5.2 c)) & (IEC 60950-1, 1.7.7.2)
F.3.6.2.2 Class II equipment with functional earth terminal N/A
marking
(IEC 60950-1, 2.6.2)
F.3.7 Equipment IP rating marking ............................ : No IP rating. 
(IEC 60065, A.5)
F.3.8 External power supply output marking Built-in component. N/A
(IEC 60065, 5.3 c))

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 35 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

F.3.9 Durability, legibility and permanence of marking P


(IEC 60065, 5.1) & (IEC 60950-1, 1.7.11)
F.3.10 Test for permanence of markings Marking is durable and legible. P
(IEC 60065, 5.1) & (IEC 60950-1, 1.7.11) Tested by water followed with
petroleum spirit.
F.4 Instructions N/A
(IEC 60065, 5.4, 5.5.2) & (IEC 60950-1, 1.7.2.1, 1.7.14, 5.1.7, 3,4,3)
a) Equipment for use in locations where children Built-in component. N/A
not likely to be present – marking
b) Instructions given for installation or initial use N/A
c) Equipment intended to be fastened in place N/A
d) Equipment intended for use only in restricted N/A
access area
e) Audio equipment terminals classified as ES3 N/A
and other equipment with terminals marked in
accordance F.3.6.1
f) Protective earthing employed as safeguard N/A
g) Protective earthing conductor current exceeding N/A
ES 2 limits
h) Symbols used on equipment N/A

i) Permanently connected equipment not provided N/A


with all-pole mains switch
j) Replaceable components or modules providing N/A
safeguard function
F.5 Instructional safeguards N/A
(IEC 60065, 5.4, 5.5)
Where “instructional safeguard” is referenced in N/A
the test report it specifies the required elements,
location of marking and/or instruction

G COMPONENTS P
G.1 Switches N/A
(IEC 60950-1, 2.8.7)
G.1.1 General requirements Not used. N/A
(IEC 60065, 14.7)
G.1.2 Ratings, endurance, spacing, maximum load N/A
(IEC 60065, 14.7)
G.2 Relays N/A
(IEC 60065, 14.4.3) & (IEC 60950-1, 2.8.7)
G.2.1 General requirements Not used. N/A
G.2.2 Overload test N/A
(IEC 60950-1, 2.8.7.2)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 36 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.2.3 Relay controlling connectors supply power N/A


G.2.4 Mains relay, modified as stated in G.2 N/A
G.3 Protection Devices P
G.3.1 Thermal cut-offs Not used. N/A
(IEC 60065, 14.6.2.2)
G.3.1.1a) Thermal cut-outs separately approved according N/A
&b) to IEC 60730 with conditions indicated in a) & b)
(IEC 60065, 14.6.2.2 a))
G.3.1.1c) Thermal cut-outs tested as part of the equipment N/A
as indicated in c)
(IEC 60065, 14.6.2.2 b))
G.3.1.2 Thermal cut-off connections maintained and N/A
secure
G.3.2 Thermal links N/A
(IEC 60065, 14.6.2.3)
G.3.2.1a) Thermal links separately tested with IEC 60691 Not used. N/A
(IEC 60065, 14.6.2.3 a))
G.3.2.1b) Thermal links tested as part of the equipment N/A
(IEC 60065, 14.6.2.3 b))
Aging hours (H) ................................................. : 
Single Fault Condition ....................................... : 
Test Voltage (V) and Insulation Resistance () . : 
G.3.3 PTC Thermistors Not used. N/A
(IEC 60065, 14.6.4) & (IEC 60950-1, 2.5)
G.3.4 Overcurrent protection devices Evaluated as part of the certified N/A
(IEC 60065, 14.6.3) & (IEC 60950-1, 2.7) component power supply
investigation.
G.3.5 Safeguards components not mentioned in G.3.1 to G.3.5 N/A
(IEC 60065, 14.6.5)
G.3.5.1 Non-resettable devices suitably rated and N/A
marking provided
(IEC 60065, 14.6.5)
G.3.5.2 Single faults conditions ...................................... : 
(IEC 60065, 14.6.5)
G.4 Connectors N/A
G.4.1 Spacings Built-in component. N/A
(IEC 60950-1, 2.10.3.1, 2.10.4.3) To be evaluated in end product.
G.4.2 Mains connector configuration .......................... : 
(IEC 60065, 15.1) & (IEC 60950-1, 3.2.4)
G.4.3 Plug is shaped that insertion into mains socket- N/A
outlets or appliance coupler is unlikely
(IEC 60065, 15.1.2) & (IEC 60950-1, 4.3.5)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 37 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.5 Wound Components N/A


G.5.1 Wire insulation in wound components ................ Evaluated as part of the certified 
component power supply
investigation.
G.5.1.2 a) Two wires in contact inside wound component, N/A
angle between 45° and 90°
(IEC 60065, 8.16) & (IEC 60950-1, 2.10.5.12)
G.5.1.2 b) Construction subject to routine testing Evaluated in certified component N/A
(IEC 60950-1, 2.10.5.11) power supply.

G.5.2 Endurance test on wound components N/A


(IEC 60065, 8.17)
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test N/A
(IEC 60065, 8.17 a))
Time (s) ............................................................ : 
Temperature (C) .............................................. : 
G.5.2.3 Wound Components supplied by mains N/A
(IEC 60065, 8.17 d))
G.5.3 Transformers N/A
(IEC 60950-1, 1.5.4)
G.5.3.1 Requirements applied (IEC61204-7, IEC61558- Evaluated in certified component 
1/-2, and/or IEC62368-1) ................................... : power supply.
(IEC 60065, 14.4.3)
Position ............................................................. : 
Method of protection ......................................... : 
G.5.3.2 Insulation N/A
Protection from displacement of windings .......... : 
(IEC 60065, 14.4) & (IEC 60950-1, C.2)
G.5.3.3 Overload test..................................................... : 
G.5.3.3.1 Test conditions N/A
(IEC 60950-1, C.1)
G.5.3.3.2 Winding Temperatures testing in the unit N/A
(IEC 60065, 11.2) & (IEC 60950-1, C.1)
G.5.3.3.3 Winding Temperatures - Alternative test method N/A
G.5.4 Motors N/A
G.5.4.1 General requirements Evaluated in certified component N/A
(IEC 60065, 4.3.7, 14.10) & (IEC 60950-1, B.1) power supply.

Position ............................................................ : 
G.5.4.2 Test conditions N/A
(IEC 60065, 4.3.7, 14.10) & (IEC 60950-1, B.2)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 38 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.5.4.3 Running overload test N/A


(IEC 60950-1, B.4)
G.5.4.4 Locked-rotor overload test N/A
(IEC 60065, 4.3.7) & (IEC 60950-1, B.5)
Test duration (days) ......................................... : 
G.5.4.5 Running overload test for d.c. motors in N/A
secondary circuits
(IEC 60950-1, B.6)
G.5.4.5.2 Tested in the unit N/A
(IEC 60950-1, B.6.2)
Electric strength test (V) .................................... : 
G.5.4.5.3 Tested on the Bench - Alternative test method; 
test time (h) ...................................................... :
(IEC 60950-1, B.6.3)
Electric strength test (V) .................................... : 
G.5.4.6 Locked-rotor overload test for d.c. motors in N/A
secondary circuits
(IEC 60065, 4.3.7) & (IEC 60950-1, B.7)
G.5.4.6.2 Tested in the unit N/A
(IEC 60950-1, B.7.2)
Maximum Temperature .................................... : 
Electric strength test (V) ................................... : 
G.5.4.6.3 Tested on the bench - Alternative test method; 
test time (h) ....................................................... :
(IEC 60950-1, B.7.3)
Electric strength test (V) .................................... : 
G.5.4.7 Motors with capacitors N/A
(IEC 60950-1, B.8)
G.5.4.8 Three-phase motors N/A
(IEC 60950-1, B.9)
G.5.4.9 Series motors N/A
(IEC 60950-1, B.10)
Operating voltage ............................................. : 
G.6 Wire Insulation N/A
G.6.1 General Evaluated as part of the certified N/A
(IEC 60065, 8.16) & (IEC 60950-1, 2.10.5.12) component power supply
investigation.
G.6.2 Solvent-based enamel wiring insulation Not used. N/A
(IEC 60065, 8.1) & (IEC 60950-1, 2.10.5.13)
G.7 Mains supply cords N/A
G.7.1 General requirements Built-in component. N/A
(IEC 60065, 16.1, 16.2) & (IEC 60950-1, 3.2.5.1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 39 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Type ................................................................. : 
Rated current (A)............................................... : 
2
Cross-sectional area (mm ), (AWG)................... : 
G.7.2 Compliance and test method N/A
(IEC 60065, 16.2) & (IEC 60950-1, 3.2.5.1)
G.7.3 Cord anchorages and strain relief for non- N/A
detachable power supply cords
G.7.3.2 Cord strain relief N/A
G.7.3.2.1 Requirements N/A
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.6)
Strain relief test force (N)................................... : 
G.7.3.2.2 Strain relief mechanism failure N/A
(IEC 60950-1, 3.2.6)
G.7.3.2.3 Cord sheath or jacket position, distance (mm) ... : 
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.7)
G.7.3.2.4 Strain relief comprised of polymeric material N/A
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.6, 3.2.7)
G.7.4 Cord Entry......................................................... : 
(IEC 60950-1, 3.1.4, 3.2.7)
G.7.5 Non-detachable cord bend protection N/A
G.7.5.1 Requirements N/A
(IEC 60950-1, 3.2.8)
G.7.5.2 Mass (g) ........................................................... : 
Diameter (m) ..................................................... : 
Temperature (C) .............................................. : 
G.7.6 Supply wiring space N/A
(IEC 60950-1, 3.2.9)
G.7.6.2 Stranded wire N/A
(IEC 60950-1, 3.3.8)
G.7.6.2.1 Test with 8 mm strand N/A
(IEC 60950-1, 3.3.8)
G.8 Varistors N/A
G.8.1 General requirements Not used. N/A
G.8.2 Safeguard against shock N/A
(IEC 60065, 14.13) & (IEC 60950-1, Annex Q)
G.8.3 Safeguard against fire N/A
G.8.3.2 Varistor overload test ........................................ : 
(IEC 60065, 14.13)
G.8.3.3 Temporary overvoltage...................................... : 

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 40 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.9 Integrated Circuit (IC) Current Limiters N/A


(IEC 60950-1, Annex CC)
G.9.1 a) Manufacturer defines limit at max. 5A. Not used. N/A
(IEC 60950-1, CC.1)
G.9.1 b) Limiters do not have manual operator or reset N/A
(IEC 60950-1, CC.1)
G.9.1 c) Supply source does not exceed 250 VA ........... : 
(IEC 60950-1, CC.1)
G.9.1 d) IC limiter output current (max. 5A) ..................... : 
(IEC 60950-1, CC.1)
G.9.1 e) Manufacturers’ defined drift .............................. : 
(IEC 60950-1, CC.1)
G.9.2 Test Program 1 N/A
(IEC 60950-1, CC.2)
G.9.3 Test Program 2 N/A
(IEC 60950-1, CC.3)
G.9.4 Test Program 3 N/A
(IEC 60950-1, CC.4)
G.10 Resistors N/A
(IEC 60065, 14.2) & (IEC 60950-1, 1.5.7)
G.10.1 General requirements Evaluated as part of the certified N/A
(IEC 60065, 14.2) & (IEC 60950-1, 1.5.7.1) component power supply
investigation.
G.10.2 Resistor test N/A
(IEC 60065, 14.2) & (IEC 60950-1, 1.5.7.2)
G.10.3 Test for resistors serving as safeguards between N/A
the mains and an external circuit consisting of a
coaxial cable
(IEC 60065, 14.2) & (IEC 60950-1, 1.5.7.3)
G.10.3.1 General requirements N/A
G.10.3.2 Voltage surge test N/A
G.10.3.3 Impulse test N/A
(IEC 60950-1, 1.5.7.3)
G.11 Capacitor and RC units P
(IEC 60065, 14.3) & (IEC 60950-1, 1.5.6)
G.11.1 General requirements P
(IEC 60065, 14.3.1) & (IEC 60950-1, 1.5.6)
G.11.2 Conditioning of capacitors and RC units Certified capacitors used. P
(IEC 60065, 14.3.1) & (IEC 60950-1, 1.5.6)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 41 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.11.3 Rules for selecting capacitors Type X2 capacitors are used P


(IEC 60065, 14.3.2) & (IEC 60950-1, 1.5.6) between lines, type Y1 capacitors
are used primary to ground comply
with IEC 60384-14 (for model
FETA7000T series).
Type Y1 capacitors are used
between Neutral and FG comply
with IEC 60384-14 (for model
FETA7000ST series).
See appended table 4.1.2.
G.12 Optocouplers N/A
Optocouplers comply with IEC 60747-5-5:2007 Evaluated as part of the certified N/A
Spacing or Electric Strength Test (specify option component power supply
and test results)................................................. : investigation.
(IEC 60065, 14.12) & (IEC 60950-1, 2.10.5.4)
Type test voltage Vini ....................................... : 
Routine test voltage, Vini,b ............................... : 
G.13 Printed boards P
(IEC 60065, 13.5) & (IEC 60950-1, 2.10.6)
G.13.1 General requirements P
G.13.2 Uncoated printed boards See appended table 5.4.2.2, P
(IEC 60065, 13.5.1) & (IEC 60950-1, 2.10.6.1) 5.4.2.3, 5.4.2.4 and 5.4.3

G.13.3 Coated printed boards Coating not used for insulation. N/A
(IEC 60065, 13.5.2) & (IEC 60950-1, 2.10.6.2)
G.13.4 Insulation between conductors on the same inner N/A
surface
(IEC 60950-1, 2.10.6.3)
Compliance with cemented joint requirements 
(Specify construction) ........................................ :
(IEC 60065, 13.5.2, 13.6, 13.7) & (IEC 60950-1,
2.10.5.5)
G.13.5 Insulation between conductors on different N/A
surfaces
(IEC 60065, 13.5.1) & (IEC 60950-1, 2.10.6.4)
Distance through insulation ................................ : 
Number of insulation layers (pcs) ..................... : 
G.13.6 Tests on coated printed boards Coating not used for insulation. N/A
(IEC 60065, 13.5.2) & (IEC 60950-1, 2.10.8)
G.13.6.1 Sample preparation and preliminary inspection N/A
(IEC 60950-1, 2.10.8.1)
G.13.6.2a) Thermal conditioning N/A
(IEC 60950-1, 2.10.8.2)
G.13.6.2b) Electric strength test N/A
(IEC 60950-1, 2.10.8.3)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 42 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

G.13.6.2c) Abrasion resistance test N/A


(IEC 60950-1, 2.10.8.4)
G.14 Coating on components terminals N/A
G.14.1 Requirements ................................................... : Coating not used for insulation. 
(IEC 60950-1, 2.10.7)
G.15 Liquid filled components N/A
G.15.1 General requirements Not used. N/A
G.15.2 Requirements N/A
G.15.3 Compliance and test methods N/A
G.15.3.1 Hydrostatic pressure test N/A
G.15.3.2 Creep resistance test N/A
G.15.3.3 Tubing and fittings compatibility test N/A
G.15.3.4 Vibration test N/A
G.15.3.5 Thermal cycling test N/A
G.15.3.6 Force test N/A
G.15.4 Compliance N/A
G.16 IC including capacitor discharge function (ICX) N/A
a) Humidity treatment in accordance with sc5.4.8 – N/A
120 hours
b) Impulse test using circuit 2 with Uc = to transient 
voltage ............................................................. :
C1) Application of ac voltage at 110% of rated voltage N/A
for 2.5 minutes
C2) Test voltage ..................................................... : 
D1) 10,000 cycles on and off using capacitor with N/A
smallest capacitance resistor with largest
resistance specified by manufacturer
D2) Capacitance ..................................................... : 
D3) Resistance ....................................................... : 

H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A


H.1 General N/A
(IEC 60950-1, M.1)
H.2 Method A N/A
(IEC 60950-1, M.2)
H.3 Method B N/A
(IEC 60950-1, M.3)
H.3.1 Ringing signal N/A
(IEC 60950-1, M.3.1)
H.3.1.1 Frequency (Hz) ................................................ : 
(IEC 60950-1, M.3.1.1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 43 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

H.3.1.2 Voltage (V) ....................................................... : 


(IEC 60950-1, M.3.1.2)
H.3.1.3 Cadence; time (s) and voltage (V) .................... : 
(IEC 60950-1, M.3.1.3)
H.3.1.4 Single fault current (mA): ................................... : 
(IEC 60950-1, M.3.1.4)
H.3.2 Tripping device and monitoring voltage.............. : 
(IEC 60950-1, M.3.2)
H.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage complied with
(IEC 60950-1, M.3.2.1)
H.3.2.2 Tripping device N/A
(IEC 60950-1, M.3.2.2)
H.3.2.3 Monitoring voltage (V) ....................................... : 
(IEC 60950-1, M.3.2.3)

J INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION P


General requirements Evaluated as part of the certified P
(IEC 60065, Annex H) & (IEC 60950-1, Annex U) component power supply
investigation.

K SAFETY INTERLOCKS N/A


K.1 General requirements No safety interlocks. N/A
(IEC 60065, 14.8) & (IEC 60950-1, 2.8.1, 2.8.2)
K.2 Components of safety interlock safeguard 
mechanism ......................................................
(IEC 60950-1, 2.8.7)
K.3 Inadvertent change of operating mode N/A
(IEC 60950-1, 2.8.3)
K.4 Interlock safeguard override N/A
(IEC 60950-1, 2.8.6)
K.5 Fail-safe N/A
(IEC 60950-1, 2.8.4)
Compliance....................................................... : 
K.6 Mechanically operated safety interlocks N/A
(IEC 60950-1, 2.8.5)
K.6.1 Endurance requirement N/A
(IEC 60950-1, 2.8.5)
K.6.2 Compliance and Test method............................ : 
(IEC 60950-1, 2.8.5)
K.7 Interlock circuit isolation N/A
(IEC 60950-1, 2.8.7)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 44 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

K.7.1 Separation distance for contact gaps & interlock 


circuit elements (type and circuit location) ........ :
(IEC 60950-1, 2.8.7.1, 2.8.7.3)
K.7.2 Overload test, Current (A) ................................. : 
(IEC 60950-1, 2.8.7.2)
K.7.3 Endurance test N/A
(IEC 60950-1, 2.8.7.3)
K.7.4 Electric strength test ......................................... : 
(IEC 60950-1, 2.8.7.4)

L DISCONNECT DEVICES N/A


L.1 General requirements Building-in component. N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.1, 3.4.2)
L.2 Permanently connected equipment N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.3)
L.3 Parts that remain energized N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.4)
L.4 Single phase equipment N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.6)
L.5 Three-phase equipment N/A
(IEC 60065, 8.18) & (IEC 60950-1, 3.4.7)
L.6 Switches as disconnect devices N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.8)
L.7 Plugs as disconnect devices N/A
(IEC 60065, 5.5.3) & (IEC 60950-1, 3.4.9)
L.8 Multiple power sources N/A
(IEC 60950-1, 3.4.11)

M EQUIPMENT CONTAINING BATTERIES AND THEIR PROTECTION CIRCUITS N/A


M.1 General requirements No battery used. N/A
(IEC 60065, 5.5.2 c)) & (IEC 60950-1, 1.7.13)
M.2 Safety of batteries and their cells N/A
(IEC 60065, 14.11.1) & (IEC 60950-1, 4.3.8)
M.2.1 Requirements N/A
(IEC 60950-1, 4.3.8)
M.2.2 Compliance and test method (identify method) .. : 
(IEC 60950-1, 4.3.8)
M.3 Protection circuits N/A
(IEC 60950-1, 4.3.8)
M.3.1 Requirements N/A
(IEC 60950-1, 4.3.8)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 45 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

M.3.2 Tests N/A


(IEC 60950-1, 4.3.8)
- Overcharging of a rechargeable battery N/A
- Unintentional charging of a non-rechargeable N/A
battery
- Reverse charging of a rechargeable battery N/A
- Excessive discharging rate for any battery N/A
M.3.3 Compliance ....................................................... : 
(IEC 60950-1, 4.3.8)
M.4 Additional safeguards for equipment containing N/A
secondary lithium battery
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Charging operating limits N/A
M.4.2.2a) Charging voltage, current and temperature........ : 
(IEC 60065, 14.11.3)
M.4.2.2 b) Single faults in charging circuitry ....................... : 
(IEC 60065, 14.11.3)
M.4.3 Fire Enclosure N/A
M.4.4 Endurance of equipment containing a secondary N/A
lithium battery
M.4.4.2 Preparation N/A
M.4.4.3 Drop and charge/discharge function tests N/A
(IEC 60065, 14.11.5)
Drop N/A
Charge N/A
Discharge N/A
M.4.4.4 Charge-discharge cycle test N/A
M.4.4.5 Result of charge-discharge cycle test N/A
M.5 Risk of burn due to short circuit during carrying N/A
M.5.1 Requirement N/A
M.5.2 Compliance and Test Method (Test of P.2.3) N/A
M.6 Prevention of short circuits and protection from N/A
other effects of electric current
M.6.1 Short circuits N/A
M.6.1.1 General requirements N/A
M.6.1.2 Test method to simulate an internal fault N/A
M.6.1.3 Compliance (Specify M.6.1.2 or alternative 
method) ........................................................... :
M.6.2 Leakage current (mA) ....................................... : 

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 46 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

M.7 Risk of explosion from lead acid and NiCd N/A


batteries
M.7.1 Ventilation preventing explosive gas N/A
concentration
M.7.2 Compliance and test method N/A
M.8 Protection against internal ignition from external N/A
spark sources of lead acid batteries
M.8.1 General requirements N/A
M.8.2 Test method N/A
M.8.2.1 General requirements N/A
3
M.8.2.2 Estimation of hypothetical volume Vz (m /s) ...... : 
M.8.2.3 Correction factors.............................................. : 
M.8.2.4 Calculation of distance d (mm) ......................... : 
M.9 Preventing electrolyte spillage N/A
M.9.1 Protection from electrolyte spillage N/A
M.9.2 Tray for preventing electrolyte spillage N/A
M.10 Instructions to prevent reasonably foreseeable 
misuse (Determination of compliance: inspection,
data review; or abnormal testing) ...................... :
(IEC 60065, 5.5.1)

N ELECTROCHEMICAL POTENTIALS N/A


Metal(s) used .................................................... : <Reference only> 
(IEC 60065, Annex F) & (IEC 60950-1, Annex J) Chassis to FG:
Chassis (High Cr stainless) =>
Screw (Ni on copper) => Tab (Ni
on copper) => PWB trace (copper)
=> softsolder => Terminal Block
(Ti on brass)
All combination are less than
0.6 V

O MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES P


Figures O.1 to O.20 of this Annex applied ......... : Considered. 
(IEC 60065, Annex E) & (IEC 60950-1, Annex F)

P SAFEGUARDS AGAINST ENTRY OF FOREIGN OBJECTS AND SPILLAGE OF N/A


INTERNAL LIQUIDS
P.1 General requirements Building-in component; Final N/A
compliance to be evaluated by the
end-product.
P.2.2 Safeguards against entry of foreign object N/A
(IEC 60065, 9.1.3) & (IEC 60950-1, 4.6.1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 47 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Location and Dimensions (mm) ........................ : 


P.2.3 Safeguard against the consequences of entry of N/A
foreign object
P.2.3.1 Safeguards against the entry of a foreign object N/A
(IEC 60950-1, 4.6.1, 4.6.4.3)
Openings in transportable equipment N/A
Transportable equipment with metalized plastic 
parts ................................................................. :
P.2.3.2 Openings in transportable equipment in relation 
to metallized parts of a barrier or enclosure
(identification of supplementary safeguard) ...... :
(IEC 60950-1, 4.6.4.2, 4.6.4.3)
P.3 Safeguards against spillage of internal liquids N/A
P.3.1 General requirements N/A
P.3.2 Determination of spillage consequences N/A
P.3.3 Spillage safeguards N/A
P.3.4 Safeguards effectiveness N/A
P.4 Metallized coatings and adhesive securing parts N/A
P.4.2 a) Conditioning testing N/A
(IEC 60950-1, 4.6.5)
Tc (°C) .............................................................. : 
Tr (°C)............................................................... : 
Ta (°C) .............................................................. : 
P.4.2 b) Abrasion testing ............................................... : 
P.4.2 c) Mechanical strength testing ................................ : 

Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING P


Q.1 Limited power sources AUX output. P
(IEC 60950-1, 2.5) Note: AUX output of Models
FETA7000T series and
FETA7000ST series are
connected to AUX output (LPS
output) of the certified component
power supply directly.
Q.1.1 a) Inherently limited output N/A
(IEC 60950-1, 2.5)
Q.1.1 b) Impedance limited output N/A
(IEC 60950-1, 2.5)
- Regulating network limited output under normal Evaluated as part of the certified N/A
operating and simulated single fault condition component power supply
investigation.
Q.1.1 c) Overcurrent protective device limited output N/A
(IEC 60950-1, 2.5)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 48 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Q.1.1 d) IC current limiter complying with G.9 N/A


(IEC 60950-1, 2.5)
Q.1.2 Compliance and test method N/A
(IEC 60950-1, 2.5)
Q.2 Test for external circuits – paired conductor cable N/A
(IEC 60950-1, 6.3)
Maximum output current (A) .............................. : 
Current limiting method ...................................... : 

R LIMITED SHORT CIRCUIT TEST N/A


R.1 General requirements N/A
R.2 Determination of the overcurrent protective N/A
device and circuit
R.3 Test method Supply voltage (V) and short-circuit 
current (A)). .................................................... :

S TESTS FOR RESISTANCE TO HEAT AND FIRE N/A


S.1 Flammability test for fire enclosures and fire Building-in component; Final N/A
barrier materials of equipment where the steady compliance to be evaluated by the
state power does not exceed 4 000 W end-product.
Samples, material ............................................. : 
Wall thickness (mm) .......................................... : 
Conditioning (C)............................................... : 
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier N/A
integrity
Samples, material ............................................. : 
Wall thickness (mm) .......................................... : 
Conditioning (C)............................................... : 
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
Test specimen does not show any additional hole N/A
S.3 Flammability test for the bottom of a fire N/A
enclosure
(IEC 60950-1, A.3)
Samples, material ............................................. : 
Wall thickness (mm) .......................................... : 

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 49 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Cheesecloth did not ignite N/A


S.4 Flammability classification of materials N/A
S.5 Flammability test for fire enclosures and fire N/A
barrier materials of equipment where the steady
state power does not exceed 4 000 W
Samples, material ............................................. : 
Wall thickness (mm) .......................................... : 
Conditioning (test condition), (C) ...................... : 
Test flame according to IEC 60695-11-20 with N/A
conditions as set out
After every test specimen was not consumed N/A
completely
After fifth flame application, flame extinguished N/A
within 1 min

T MECHANICAL STRENGTH TESTS P


T.1 General requirements P
T.2 Steady force test, 10 N ..................................... : Checked by inspection. 
(IEC 60065, 13.3.1) & (IEC 60950-1, 4.2.2)
T.3 Steady force test, 30 N ..................................... : Building-in component. 
(IEC 60065, 13.3.1) & (IEC 60950-1, 4.2.3)
T.4 Steady force test, 100 N ................................... : Building-in component. 
(IEC 60065, 9.1.7)
T.5 Steady force test, 250 N ................................... : Building-in component. 
(IEC 60065, 9.1.7) & (IEC 60950-1, 4.2.4)
T.6 Enclosure impact test Building-in component. N/A
(IEC 60065, 12.1.4) & (IEC 60950-1, 4.2.5)
Fall test N/A
Swing test N/A
T.7 Drop test .......................................................... : Building-in component. 
(IEC 60065, 12.1.5) & (IEC 60950-1, 4.2.6)
T.8 Stress relief test ................................................ : Building-in component. 
(IEC 60065, 12.1.6) & (IEC 60950-1, 4.2.7)
T.9 Impact Test (glass) N/A
(IEC 60065, 19.6.1) & (IEC 60950-1, 4.2.5)
T.9.1 General requirements N/A
T.9.2 Impact test and compliance N/A
Impact energy (J)............................................... : 
Height (m) ......................................................... : 
T.10 Glass fragmentation test .................................... : 
(IEC 60065, 19.6.2)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 50 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

T.11 Test for telescoping or rod antennas N/A


(IEC 60065, 12.6)
Torque value (Nm) ............................................ : 

U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND PROTECTION N/A


AGAINST THE EFECTS OF IMPLOSION
U.1 General requirements N/A
(IEC 60065, 18.1) & (IEC 60950-1, 4.2.8)
U.2 Compliance and test method for non-intrinsically N/A
protected CRTs
(IEC 60065, 18.2)
U.3 Protective Screen .............................................. : 

V DETERMINATION OF ACCESSIBLE PARTS (FINGERS, PROBES AND WEDGES) N/A


V.1 Accessible parts of equipment Building-in component. N/A
(IEC 60065, 9.1.1.3, 9.1.3, 9.1.4) & (IEC 60950-1,
1.7.2.5, 2.1.1.1, EE.5)
V.2 Accessible part criterion N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 51 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

4.1.2 TABLE: List of critical components P


Object / part No. Manufacturer/ Type / model Technical data Standard Mark(s) of
1
trademark conformity
Terminal Blocks Osada Co., Ltd. OTB-910-BL (PRI/GND/SEC) UL 1059 UL (E121961)
(TB1, TB2, TB3, 600V, 115A, 130
TB4) C
Base of Terminal Wintech Polymer 3316 PBT, RTI: 140 C, IEC 60695-11- UL (E213445)
Blocks (TB1, TB2, Ltd. V-0, Minimum 0.38 10
TB3, TB4) mm thick.
X-Capacitors (C11, (SEMKO) Cowell PCX2 339 (Line-to-Line) 305 IEC/EN 60384- SEMKO
C12, C13) Fashion Co., Ltd. Vac, 0.68μF, Class 14 (SE/0256-4J)
(for model Pilkor Electronics X2 UL 60384-14 UL (E165646)
FETA7000T-48, (UL) Cowell
FETA7000T-144) Fashion Co., Ltd.
X-Capacitors (C11, (SEMKO) Cowell PCX2 339 (Line-to-Line) 305 IEC/EN 60384- SEMKO
C12, C13, C14) Fashion Co., Ltd. Vac, 0.68μF, Class 14 (SE/0256-4J)
(for model Pilkor Electronics X2 UL 60384-14 UL (E165646)
FETA7000ST-48, (UL) Cowell Capacitor (C14) is
FETA7000ST-144) Fashion Co., Ltd. connected to each
capacitor (C11,
C12 and C13) in
series.
Inductor (L11) Toho Zinc Co., FKY-160GK- (Line-to-Line) Core: -- --
(for model Ltd. 3010HRS Ferrite. See
FETA7000T-48, Enclosure Id. 2-01
FETA7000T-144) for detail.

Core Case of Wintech Polymer CRN7000 PBT, RTI: 140 C, IEC 60695-11- UL (E213445)
Inductor (L11) Ltd. V-0, Minimum 0.32 10
(for model mm thick.
FETA7000T-48,
FETA7000T-144)
Y-Capacitors (C14, Murata Mfg. Co., KX (PRI-to-GND) 250 IEC 60384-14 VDE
C15, C16) (for Ltd. V, 3300 pF, Class (40002831)
model FETA7000T- Y1 UL (E37921)
UL 60384-14
48, FETA7000T-
144)
Y-Capacitor (C15) Murata Mfg. Co., KX (Neutral-to-GND) IEC 60384-14 VDE
(for model Ltd. 250 V, 3300 pF, (40002831)
FETA7000ST-48, Class Y1 UL 60384-14 UL (E37921)
FETA7000ST-144)
Switching Power Cosel Co., Ltd. FETA2500BA- (PRI/SEC/GND) IEC 60950-1, UL (CB)
Supplies (PS1, PS2, 48 Input: 200-240Vac IEC 62368-1 (4788327644)
PS3) 50-60Hz 13.8 A UL 60950-1 UL (E132067)
Output: 48Vdc 52A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 52 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Secondary Internal Interchangeable Interchangeable (SEC) Minimum 80 UL 758 UL


Wire C, Minimum 300
Vac
Insulation tube Nikkan Industries E-651U-1 Supplementary UL 224 UL (E88468)
Co., Ltd. Insulation, Silicone
rubber, 300V, 200
C
Insulation sheet Sabic Japan L L FR700 Basic Insulation, IEC 60695-11- UL (E207780)
C PC, RTI: 130 C, 10
V-0, 0.25 mm thick.
Alternate AGC CARBOGLASS Basic Insulation、 IEC 60695-11- UL (E141248)
Polycarbonate CFR230B PC, RTI: 130 C, 10
Co., Ltd.
V-0, 0.25 mm thick.
Chassis and Cover -- -- High Cr stainless -- --
1 mm thick. See
Enclosure Id. 5-01,
5-02 for detail.
PWB Interchangeable Interchangeable V-0, minimum 130 UL 796 UL
C
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
2)
Description line content is optional. Main line description needs to clearly detail the component used for
testing
The CBTL has verified the component information.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 53 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

4.8.4, 4.8.5 TABLE: Lithium coin/button cell batteries mechanical tests N/A
(The following mechanical tests are conducted in the sequence noted.)
4.8.4.2 TABLE: Stress relief test 
Part Material Oven Temperature (°C) Comments
-- -- -- --
4.8.4.3 TABLE: Battery replacement test 
Battery part no. ............................................................ : —
Battery Installation/withdrawal Battery Installation/Removal Cycle Comments
1 --
2 --
3 --
4 --
5 --
6 --
8 --
9 --
10 --
4.8.4.4 TABLE: Drop test 

Impact Area Drop Distance Drop No. Observations

-- -- 1 --

-- -- 2 --

-- -- 3 --
4.8.4.5 TABLE: Impact 
Impacts per surface Surface tested Impact energy (Nm) Comments
-- -- -- --
4.8.4.6 TABLE: Crush test 
Test position Surface tested Crushing Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:
No battery used.

4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result N/A
Test position Surface tested Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 54 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

No battery used.

5.2 TABLE: Classification of electrical energy sources P


5.2.2.2 – Steady State Voltage and Current conditions

Location (e.g. Parameters


Supply
No. circuit Test conditions U I ES Class
Voltage
designation) Hz
(Vrms or Vpk) (Apk or Arms)
1 240 Vac, 60 144 Vdc output Normal 158.4 Vdc -- DC
Hz (model
FETA7000T-
144) (#) Abnormal -- -- -- ES3

Single fault – -- -- --
SC/OC
2 240 Vac, 60 48 Vdc output Normal ($) 52.8 Vdc -- DC
Hz (model
FETA7000T-
48) (###) Abnormal 55.35 Vdc -- DC
VR31 maximum ES1
Volume
Single fault – Maximum 52.8 -- DC
SC/OC Vdc
R418 SC
3 240 Vac, 60 AUX output Normal (4+) Maximum 12.1 -- DC
Hz (CN2 (CN1) 1 Vdc (+)
pin to 2 pin) of
model Maximum 12.1 -- DC
FETA7000T- Vdc (3+)
144 (#) (##)
Single fault – Maximum 27.99 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 11.95 -- DC
T701 4 pin SC Vdc (3+)
(4+)
Single fault – Maximum 42.78 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 11.99 -- DC ES1
D810 (K) SC Vdc (3+)
(4+)
Single fault – Maximum 32.8 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 10.58 -- DC
D811 (K) SC Vdc (3+)
(4+)
Single fault – Maximum 26.0 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 12.05 -- DC
T701 2 pin SC Vdc (3+)
(4+)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 55 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Single fault – 12.1 Vdc (+) -- DC


SC/OC
R405 SC (2+) 12.2 Vdc (3+) -- DC

5.2.2.3 - Capacitance Limits


Location (e.g. Parameters
Supply
No. circuit Test conditions ES Class
Voltage Capacitance, nF Upk (V)
designation)
1 264 Vac, Input connector Normal 3.3 < 420
60 Hz of model
FETA7000T- Abnormal -- --
144 (2#) ES1
Single fault – -- --
(R line and SC/OC
Ground)
2 264 Vac, Input connector Normal 3.3 < 420
60 Hz of model
Abnormal -- --
FETA7000T-
ES1
144 (2#) Single fault – -- --
(S line and SC/OC
Ground)
3 264 Vac, Input connector Normal 3.3 < 420
60 Hz of model
Abnormal -- --
FETA7000T-
ES1
144 (2#) Single fault – -- --
(T line and SC/OC
Ground)
4 264 Vac, Input connector Normal 680 < 420
60 Hz of model
Abnormal -- --
FETA7000T-
ES3
144 (2#) Single fault – -- --
(R line and S SC/OC
line)
5 264 Vac, Input connector Normal 680 < 420
60 Hz of model
FETA7000T- Abnormal -- --
ES3
144 (2#) Single fault – -- --
(S line and T SC/OC
line)
6 264 Vac, Input connector Normal 680 < 420
60 Hz of model
Abnormal -- --
FETA7000T-
ES3
144 (2#) Single fault – -- --
(T line and R SC/OC
line)
7 415 Vac, Input connector Normal 3.3 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES1
(Neutral and Single fault – -- --
Ground) SC/OC

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 56 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

8 415 Vac, Input connector Normal 340 < 420


60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L1 line and L2 SC/OC
line)
9 415 Vac, Input connector Normal 340 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L2 line and L3 SC/OC
line)
10 415 Vac, Input connector Normal 340 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L3 line and L1 SC/OC
line)
11 415 Vac, Input connector Normal 340 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L1 line and SC/OC
Neutral)
12 415 Vac, Input connector Normal 340 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L2 line and SC/OC
Neutral)
13 415 Vac, Input connector Normal 340 < 420
60Hz of model
FETA7000ST- Abnormal -- --
144 (3#) ES3
Single fault – -- --
(L3 line and SC/OC
Neutral)
5.2.2.4 - Single Pulses
Location (e.g. Parameters
Supply
No. circuit Test conditions ES Class
Voltage Duration (ms) Upk (V) Ipk (mA)
designation)
-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
5.2.2.5 - Repetitive Pulses
Location (e.g. Parameters
Supply
No. circuit Test conditions ES Class
Voltage Off time (ms) Upk (V) Ipk (mA)
designation)
-- -- -- Normal -- -- -- --

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 57 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Abnormal -- -- --
Single fault – -- -- --
SC/OC
Test Conditions:
Normal – maximum Voltage with in output voltage range.
Supplementary information: SC=Short Circuit, OC=Short Circuit
(+) CN2 (CN1) 1pin is connected to Ground.
(2+) For FETA7000T-144 (Maximum voltage within output voltage range: 158.4V, 47.28A)
(3+) CN2 (CN1) 1pin is not connected to Ground (floating).
(4+) For PS1 (FETA2500BA-48)
(#) Test performed on Model FETA7000T-144 representative of model FETA7000ST-144 because secondary
circuits are identical.
(##) This test was performed to confirm whether the output of model FETA7000T-144 would affect interface circuit.
Interface circuits are connected to AUX circuits of the certified component power supply FETA2500BA-48.
Therefore, voltage between CN2 (CN1) 1 pin and 2 pin connected to AUX circuits was measured as
representative. This measurement covers all interface circuits.
(###) Test performed on Model FETA7000T-48 representative of model FETA7000ST-48 because secondary
circuits are identical.
(2#) Test performed on Model FETA7000T-144 representative of model FETA7000T-48 because primary circuits
are identical.
(3#) Test performed on Model FETA7000ST-144 representative of model FETA7000ST-48 because primary
circuits are identical.
($) This result is referred to the result of 48 Vdc output of Model FETA2500BA-48, Because 48 Vdc outputs of
Models FETA7000T series and FETA7000ST series are is connected to 48 Vdc output of Model FETA2500BA-48
directly.

5.4.1.4, TABLE: Temperature measurements P


6.3.2, 9.0,
B.2.6
Supply voltage (V) ................... : See See See See 
Below Below Below Below
Ambient Tmin (C) ..................... : -- -- -- -- 
Ambient Tmax (C) .................... : See See See See 
Below Below Below Below
Tma (C) ................................. : See See See See 
Below Below Below Below
T (C) Allowed Tmax
Maximum measured temperature T of part/at:
(C)
FETA7000T-144, Power Source Connection: -- -- -- -- --
3 PHASE, Delta system
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% --
load load load load
(144V, (144V, (144V, (144V,
52A) 52A) 52A) 52A)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 58 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Ambient 27 -- 27 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 67 80 58 71 130 (TB1)
Terminal Block (TB3) 70 83 62 75 130 (TB3)
Inductor (L11) 105 118 78 91 140 (RTI)
Capacitor (C13) 78 91 66 79 110 (C13)
Capacitor (C16) 73 86 62 75 125 (C16)
Capacitor (C21) 74 87 65 78 110 (C21)
PWB near TB211 77 90 67 80 130 (PWB)
PWB near IC491 80 93 70 83 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 96 74 87 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 93 106 83 96 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 83 96 74 87 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 91 104 83 96 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 80 93 71 84 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 87 100 76 89 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 95 108 85 98 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 101 114 90 103 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 82 95 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 100 113 91 104 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 53 66 39 52 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 55 68 41 54 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 93 106 84 97 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 77 90 67 80 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 80 93 70 83 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 84 97 75 88 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 92 105 82 95 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 81 94 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 99 112 90 103 130 (PWB)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 59 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

PWB near T701 (FETA2500BA-48/PS3) 89 102 80 93 130 (PWB)


Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% load 50% --
load load (144V, load
(144V, (144V, 26A) (144V,
26A) 26A) 26A)
Ambient 24 -- 24 -- --
Tma -- 60 -- 60 --
Terminal Block (TB1) 43 79 41 77 130 (TB1)
Terminal Block (TB3) 45 81 44 80 130 (TB3)
Inductor (L11) 57 93 50 86 140 (RTI)
Capacitor (C13) 48 84 45 81 110 (C13)
Capacitor (C16) 46 82 43 79 125 (C16)
Capacitor (C21) 48 84 45 81 110 (C21)
PWB near TB211 47 83 45 81 130 (PWB)
PWB near IC491 53 89 51 87 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 50 86 48 84 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 53 89 51 87 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 55 91 53 89 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 58 94 55 91 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 54 90 51 87 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 56 92 52 88 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 54 90 51 87 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 57 93 54 90 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 55 91 52 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 62 98 59 95 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 32 68 29 65 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 33 69 30 66 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 62 98 59 95 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 49 85 46 82 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 54 90 51 87 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 88 50 86 130 (Class F)
48/PS3)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 60 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Sec. side (FETA2500BA- 54 90 52 88 130 (Class F)


48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 55 91 52 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 63 99 60 96 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 98 59 95 130 (PWB)
FETA7000T-144, Power Source Connection: -- -- -- -- --
3 PHASE, Star system,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% --
load load load load
(144V, (144V, (144V, (144V,
52A) 52A) 52A) 52A)
Ambient 24 -- 24 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 56 72 50 66 130 (TB1)
Terminal Block (TB3) 58 74 53 69 130 (TB3)
Inductor (L11) 84 100 66 82 140 (RTI)
Capacitor (C13) 63 79 56 72 110 (C13)
Capacitor (C16) 60 76 53 69 125 (C16)
Capacitor (C21) 61 77 55 71 110 (C21)
PWB near TB211 63 79 57 73 130 (PWB)
PWB near IC491 66 82 60 76 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 67 83 61 77 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 74 90 69 85 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 71 87 65 81 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 76 92 72 88 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 66 82 61 77 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 72 88 66 82 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 76 92 69 85 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 81 97 74 90 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 69 85 63 79 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 83 99 77 93 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 43 59 34 50 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 45 61 36 52 140 (RTI)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 61 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Inductor (L301) (FETA2500BA-48/PS2) 78 94 73 89 150 (RTI)


PWB near TR302 (FETA2500BA-48/PS2) 62 78 56 72 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 66 82 61 77 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 68 84 63 79 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 74 90 68 84 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 69 85 64 80 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 82 98 77 93 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 74 90 69 85 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% load 50% --
load load (144V, load
(144V, (144V, 26A) (144V,
26A) 26A) 26A)
Ambient 25 -- 25 -- --
Tma -- 60 -- 60 --
Terminal Block (TB1) 45 80 43 78 130 (TB1)
Terminal Block (TB3) 47 82 45 80 130 (TB3)
Inductor (L11) 58 93 51 86 140 (RTI)
Capacitor (C13) 50 85 46 81 110 (C13)
Capacitor (C16) 48 83 45 80 125 (C16)
Capacitor (C21) 49 84 47 82 110 (C21)
PWB near TB211 49 84 46 81 130 (PWB)
PWB near IC491 54 89 52 87 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 86 48 83 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 54 89 51 86 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 91 53 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 59 94 56 91 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 55 90 52 87 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 57 92 53 88 130 (RTI)
Transformer (T301 coil Pri. side (FETA2500BA- 55 90 52 87 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 59 94 56 91 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 56 91 53 88 110 (Class B)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 62 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

PWB near T301 (FETA2500BA-48/PS2) 64 99 60 95 130 (PWB)


Inductor (L101) (FETA2500BA-48/PS2) 34 69 30 65 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 35 70 31 66 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 64 99 61 96 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 50 85 47 82 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 56 91 53 88 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 54 89 51 86 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 56 91 53 88 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 57 92 54 89 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 64 99 61 96 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 63 98 60 95 130 (PWB)
FETA7000T-48, Power Source Connection: -- -- -- -- --
3 PHASE, Delta system,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% load 100% --
load load (48V, load
(48V, (48V, 148.2A) (48V,
148.2A) 148.2A) 148.2A)
Ambient 26 -- 27 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 61 75 56 69 130 (TB1)
Terminal Block (TB3) 75 89 71 84 130 (TB3)
Inductor (L11) 95 109 74 87 140 (RTI)
Capacitor (C13) 70 84 62 75 110 (C13)
Capacitor (C16) 67 81 60 73 125 (C16)
Capacitor (C21) 74 88 68 81 110 (C21)
PWB near TB211 69 83 62 75 130 (PWB)
PWB near IC491 72 86 66 79 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 75 89 69 82 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 84 98 78 91 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 78 92 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 86 100 81 94 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 76 90 69 82 130 (PWB)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 63 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Terminal Block (TB101) (FETA2500BA-48/PS2) 79 93 72 85 130 (RTI)


Transformer (T301) coil Pri. side (FETA2500BA- 81 95 75 88 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 90 104 83 96 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 78 92 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 90 104 84 97 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 46 60 37 50 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 47 61 38 51 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 85 99 79 92 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 69 83 62 75 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 78 92 72 85 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 78 92 72 85 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 86 100 79 92 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 76 90 70 83 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 91 105 85 98 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 83 97 76 89 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 50% load 50% load 50% load 50% load --
(48V, (48V, (48V, (48V,
74.1A) 74.1A) 74.1A) 74.1A)
Ambient 26 -- 27 -- --
Tma -- 60 -- 60 --
Terminal Block (TB1) 45 79 44 77 130 (TB1)
Terminal Block (TB3) 49 83 48 81 130 (TB3)
Inductor (L11) 57 91 52 85 140 (RTI)
Capacitor (C13) 49 83 47 80 110 (C13)
Capacitor (C16) 47 81 46 79 125 (C16)
Capacitor (C21) 50 84 49 82 110 (C21)
PWB near TB211 48 82 47 80 130 (PWB)
PWB near IC491 53 87 52 85 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 85 50 83 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 54 88 52 85 130 (Class F)
48/PS1)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 64 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Transformer (T701) coil (FETA2500BA-48/PS1) 56 90 55 88 110 (Class B)


PWB near T301 (FETA2500BA-48/PS1) 58 92 57 90 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 56 90 55 88 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 55 89 54 87 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 53 87 52 85 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 57 91 56 89 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 58 92 56 89 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 61 95 60 93 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 33 67 31 64 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 34 68 32 65 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 62 96 60 93 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 49 83 48 81 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 58 92 56 89 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 53 87 52 85 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 55 89 54 87 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 90 55 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 62 96 61 94 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 96 61 94 130 (PWB)
FETA7000T-48, Power Source Connection: -- -- -- -- --
3 PHASE, Star system,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% load 100% --
load load (48V, load
(48V, (48V, 148.2A) (48V,
148.2A) 148.2A) 148.2A)
Ambient 24 -- 25 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 61 77 53 68 130 (TB1)
Terminal Block (TB3) 74 90 67 82 130 (TB3)
Inductor (L11) 93 109 70 85 140 (RTI)
Capacitor (C13) 68 84 59 74 110 (C13)
Capacitor (C16) 65 81 57 72 125 (C16)
Capacitor (C21) 73 89 65 80 110 (C21)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 65 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

PWB near TB211 67 83 59 74 130 (PWB)


PWB near IC491 71 87 63 78 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 73 89 66 81 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 82 98 75 90 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 76 92 69 84 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 84 100 78 93 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 74 90 66 81 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 77 93 68 83 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 79 95 71 86 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 88 104 80 95 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 77 93 69 84 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 88 104 81 96 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 45 61 35 50 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 47 63 36 51 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 84 100 76 91 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 67 83 59 74 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 76 92 68 83 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 77 93 69 84 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 84 100 76 91 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 74 90 67 82 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 90 106 83 98 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 82 98 73 88 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 50% load 50% load 50% load 50% load --
(48V, (48V, (48V, (48V,
74.1A) 74.1A) 74.1A) 74.1A)
Ambient 25 -- 25 -- --
Tma -- 60 -- 60 --
Terminal Block (TB1) 45 80 43 78 130 (TB1)
Terminal Block (TB3) 48 83 47 82 130 (TB3)
Inductor (L11) 56 91 50 85 140 (RTI)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 66 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Capacitor (C13) 48 83 46 81 110 (C13)


Capacitor (C16) 47 82 44 79 125 (C16)
Capacitor (C21) 50 85 48 83 110 (C21)
PWB near TB211 47 82 45 80 130 (PWB)
PWB near IC491 53 88 50 85 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 50 85 48 83 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 53 88 51 86 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 91 53 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 57 92 55 90 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 56 91 53 88 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 55 90 52 87 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 53 88 50 85 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 56 91 54 89 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 57 92 55 90 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 60 95 58 93 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 33 68 29 64 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 34 69 30 65 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 61 96 58 93 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 48 83 46 81 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 57 92 55 90 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 87 50 85 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 55 90 52 87 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 91 53 88 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 62 97 59 94 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 97 59 94 130 (PWB)
FETA7000ST-144, Power Source Connection: 3 -- -- -- -- --
PHASE, (3/N/PE) system,
Supply voltage/ frequency 311Vac 311Vac 457Vac 457Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% load 100% --
load load (144V, load
(144V, (144V, 52A) (144V,
52A) 52A) 52A)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 67 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Ambient 28 -- 26 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 63 75 55 69 130 (TB1)
Terminal Block (TB3) 61 73 54 68 130 (TB3)
Capacitor (C11) 72 84 62 76 110 (C11)
Capacitor (C15) 70 82 59 73 125 (C15)
Capacitor (C21) 67 79 58 72 110 (C21)
PWB near TB211 78 90 67 81 130 (PWB)
PWB near IC491 78 90 68 82 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 95 74 88 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 83 95 74 88 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 76 88 66 80 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 94 106 85 99 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 70 82 59 73 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 79 91 68 82 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 86 98 76 90 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 80 92 69 83 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 106 118 96 110 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 75 87 64 78 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 85 97 74 88 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 54 66 38 52 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 53 65 38 52 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 65 77 43 57 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 77 89 66 80 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 73 85 62 76 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 81 93 74 88 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 78 90 70 84 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 92 104 84 98 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 69 81 61 75 130 (PWB)
Supply voltage/ frequency 311Vac 311Vac -- -- --
/60Hz /60Hz

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 68 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Condition 50% load 50% load -- -- --


(144V, (144V,
26A) 26A)
Ambient 24 -- -- -- --
Tma -- 60 -- -- --
Terminal Block (TB1) 43 79 -- -- 130 (TB1)
Terminal Block (TB3) 43 79 -- -- 130 (TB3)
Capacitor (C11) 49 85 -- -- 110 (C11)
Capacitor (C15) 47 83 -- -- 125 (C15)
Capacitor (C21) 46 82 -- -- 110 (C21)
PWB near TB211 49 85 -- -- 130 (PWB)
PWB near IC491 54 90 -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 88 -- -- 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 52 88 -- -- 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 54 90 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 60 96 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 50 86 -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 54 90 -- -- 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 57 93 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 68 104 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 53 89 -- -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 57 93 -- -- 130 (TB101)
Inductor (L101) (FETA2500BA-48/PS2) 33 69 -- -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 34 70 -- -- 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 41 77 -- -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 52 88 -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 47 83 -- -- 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 51 87 -- -- 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 55 91 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 59 95 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 50 86 -- -- 130 (PWB)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 69 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

FETA7000ST-48, Power Source Connection: 3 -- -- -- -- --


PHASE, (3/N/PE) system
Supply voltage/ frequency 311Vac 311Vac 457Vac 457Vac --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% load 100% --
load load (48V, load
(48V, (48V, 148.2A) (48V,
148.2A) 148.2A) 148.2A)
Ambient 23 -- 22 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 56 73 48 66 130 (TB1)
Terminal Block (TB3) 66 83 59 77 130 (TB3)
Capacitor (C11) 62 79 52 70 110 (C11)
Capacitor (C15) 65 82 55 73 125 (C15)
Capacitor (C21) 64 81 56 74 110 (C21)
PWB near TB211 71 88 61 79 130 (PWB)
PWB near IC491 71 88 61 79 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 69 86 60 78 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 75 92 66 84 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 72 89 63 81 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 89 106 81 99 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 67 84 58 76 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 71 88 61 79 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 79 96 68 86 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 74 91 64 82 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 97 114 87 105 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 69 86 58 76 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 78 95 67 85 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 48 65 34 52 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 48 65 34 52 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 60 77 40 58 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 70 87 60 78 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 65 82 57 75 130 (Class F)
48/PS3)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 70 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Sec. side (FETA2500BA- 74 91 66 84 130 (Class F)


48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 73 90 65 83 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 84 101 77 95 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 64 81 56 74 130 (PWB)
Supply voltage/ frequency 311Vac 311Vac -- -- --
/60Hz /60Hz
Condition 50% load 50% load -- -- --
(48V, (48V,
74.1A) 74.1A)
Ambient 24 -- -- -- --
Tma -- 60 -- -- --
Terminal Block (TB1) 44 80 -- -- 130 (TB1)
Terminal Block (TB3) 47 83 -- -- 130 (TB3)
Capacitor (C11) 48 84 -- -- 110 (C11)
Capacitor (C15) 49 85 -- -- 125 (C15)
Capacitor (C21) 48 84 -- -- 110 (C21)
PWB near TB211 50 86 -- -- 130 (PWB)
PWB near IC491 54 90 -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 53 89 -- -- 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 92 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 62 98 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 53 89 -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 55 91 -- -- 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 58 94 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 67 103 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 55 91 -- -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 58 94 -- -- 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 35 71 -- -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 35 71 -- -- 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 42 78 -- -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 53 89 -- -- 130 (PWB)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 71 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Pri. side (FETA2500BA- 48 84 -- -- 130 (Class F)


48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 52 88 -- -- 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 92 -- -- 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 59 95 -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 52 88 -- -- 130 (PWB)
Simulated Abnormal Operating Conditions – -- -- -- --
--
Maximum Load at output terminals.
Model FETA7000T-48 -- -- -- -- --
52.8 V output overload (+) (2+) -- -- -- -- --
Ambient 25 Calculat -- -- --
ed to
Tma
Tma -- 60 -- -- --
Supply voltage / frequency 264 Vac 264 Vac -- -- --
/ 60 Hz / 60 Hz
Transformer (T301) Sec. side coil of PS1 101 136 -- -- 300
Transformer (T701) of PS1 81 116 -- -- 300
Transformer (T301) Sec. side coil of PS2 107 142 -- -- 300
Transformer (T701) of PS2 82 117 -- -- 300
Transformer (T301) Sec. side coil of PS3 101 136 -- -- 300
Transformer (T701) of PS3 80 115 -- -- 300
Model FETA7000T-144 -- -- -- -- --
158.4 V output overload (+) (3+) -- -- -- -- --
Ambient 26 Calculat -- -- --
ed to
Tma
Tma -- 60 -- -- --
Supply voltage / frequency 264 Vac 264 Vac -- -- --
/ 60 Hz / 60 Hz
Transformer (T301) Sec. side coil of PS1 101 135 -- -- 300
Transformer (T701) of PS1 81 115 -- -- 300
Transformer (T301) Sec. side coil of PS2 108 142 -- -- 300
Transformer (T701) of PS2 84 118 -- -- 300
Transformer (T301) Sec. side coil of PS3 100 134 -- -- 300
Transformer (T701) of PS3 80 114 -- -- 300
Supplementary information:
(+): Maximum voltage with in output voltage range
(2+): Model FETA7000T-48 is the representative of Model FETA7000ST-48.
(3+): Model FETA7000T-144 is the representative of FETA7000ST-144.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 72 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

t1 (°C) R1 () t2 (°C) R2 () T (C) Allowe Insulati


Temperature T of winding: d Tmax on
(C) class
-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Tma should be considered as directed by appliable requirement
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9)

5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics N/A


Penetration (mm) .......................................................... : -- 
Object/ Part No./Material Manufacturer/t T softening (°C)
rademark
-- -- --
Supplementary information:
Ball pressure test applied.

5.4.1.10.3 TABLE: Ball pressure test of thermoplastics P


Allowed impression diameter (mm) ................................ :  2 mm 
Object/Part No./Material Manufacturer/trademark Test temperature (C) Impression diameter (mm)
Bobbin (Core Case) of Wintech Polymer Ltd. 133 1.0
Inductors (L11), PBT, Type
CRN7000
Base of Terminal Block Wintech Polymer Ltd. 125 0.8
(TB1, TB3), PBT, Type 3316
Supplementary information: --

5.4.2.2, TABLE: Minimum Clearances/Creepage distance P


5.4.2.4 and
5.4.3
Clearance (cl) and creepage Up U r.m.s. Frequenc Required cl Required3 cr
1 2
distance (cr) at/of/between: (V) (V) y (kHz) cl (mm) (mm) cr (mm) (mm)
Functional: -- -- -- -- -- -- --
Pri. – Pri. (R to S, S to T of < 420 < 250 < 30 1.5 (1.27) 10.6 2.5 10.6
Terminal Block (TB1)) (+)
Pri. – Pri. (L1 to L2, L2 to L3 of < 420 < 250 < 30 1.5 (1.27) 10.6 2.5 10.6
Terminal Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 4.3 2.5 4.3
between R and S of Terminal
Block (TB1)) (+)
Pri. – Pri. (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 5.3 2.5 5.3
between L3 and L2 of Terminal
Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 4.0 2.5 4.0

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 73 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Capacitors (C13)) (+)


Pri. – Pri. (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 5.3 2.5 5.3
between Capacitor (C13) and L2
of Terminal Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 3.1 2.5 3.1
between Capacitors (C11, C12)
and L2 of Terminal Block (TB1))
(3+)
Pri. – Pri. (PWB Trace T to R at < 420 < 250 < 30 1.5 (1.27) 4.0 2.5 4.0
Inductor (L11)) (+)
Basic/supplementary: -- -- -- -- -- -- --
Pri. – Gnd (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 7.5 2.5 7.5
Capacitor (C14, C16) (+))
Pri. – Gnd (PWB Trace at < 420 < 250 < 30 1.5 (1.27) 9.0 2.5 9.0
between FG of Terminal Block
(TB2) and N of Terminal Block
(TB2) (3+))
Reinforced: -- -- -- -- -- -- --
Pri. - Sec. (Screw of TR304 to 1050 349 1340 2.9 (2.54) 7.0 7.0 28.0
T301 core) (2+)
Pri. - Sec. (Wire of Internal fan to 1050 349 1340 2.9 (2.54) 15.2 7.0 33.2
T301 core) (2+)
Pri. - Sec. (T702 core to output 976 428 589.8 2.9 (2.54) 11.1 8.6 13.3
terminal (2+)
Pri. - Sec. (TR702 to output 976 428 589.8 2.9 (2.54) 10.5 8.6 10.5
terminal) (2+)
Pri. - Sec. (PWB Trace at 512 288 1340 2.9 (2.54) 7.0 5.8 7.0
between TB211 and TB112) (+)
Pri. - Sec. (PWB Trace at < 420 < 250 1340 2.9 (2.54) 8.5 5.0 8.5
between PS1/+V out and L2 of
Terminal Block (TB1)) (3+)
Pri. - Sec. (PWB Trace at PC204 448 245 1340 2.9 (2.54) 6.2 4.9 6.2
3pin to T301 6, 7, 8pin) (2+)
Pri. - Sec. (PWB Trace at C125 440 246 < 30 2.9 (2.54) 8.8 5.0 8.8
to T301 9, 10, 11pin (2+)
Pri. - Sec. (PWB Trace at L311 728 306 < 30 2.9 (2.54) 8.5 6.2 8.5
pin to T301 3, 4, 5pin (2+)
Pri. - Sec. (PWB Trace at Optical < 420 < 250 < 30 2.9 (2.54) 6.5 4.8 6.5
Isolators (PC201, PC203,
PC204, PC331, PC332) (2+)
Pri. - Sec., (PWB Trace at 408 238 1340 2.9 (2.54) 7.0 4.8 7.0
between TR302 and T301 3, 4,
5pin (2+)
Pri. - Sec., (PWB Trace at C744 496 310 589.8 2.9 (2.54) 6.7 6.2 6.7
to T701 1pin (2+)
Pri. - Sec., (PWB Trace at TR702 968 425 589.8 2.9 (2.54) 10.0 8.5 10.0
to Output terminal trace (2+)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 74 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Supplementary information:
Note 1: Only for frequency above 30 kHz
Note 2: See table 5.4.2.4 if this is based on electric strength test
Note 3: Provide Material Group
(+) FETA7000T-144/-48
(2+) FETA2500BA-48
(3+) FETA7000ST-144/-48
The value in the above table is the required clearance of operated at up to 3000 m sea level. The multiplication
factors of table 17 applied. For operation up to 2000 m sea level, see the value in the parentheses.

5.4.2.3 TABLE: Minimum Clearances distances using required withstand voltage P


Overvoltage Category (OV) ........................................................................... : II
Pollution Degree ........................................................................................... : 2
Clearance distanced between: Required withstand Required cl Measured cl (mm)
voltage (mm)
Functional: -- -- --
Pri. – Pri. (R to S, S to T of Terminal 2500 1.8 (1.5) 10.6
Block (TB1)) (+)
Pri. – Pri. (L1 to L2, L2 to L3 of 2500 1.8 (1.5) 10.6
Terminal Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at between R 2500 1.8 (1.5) 4.3
and S of Terminal Block (TB1)) (+)
Pri. – Pri. (PWB Trace at between L3 2500 1.8 (1.5) 5.3
and L2 of Terminal Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at Capacitors 2500 1.8 (1.5) 4.0
(C13)) (+)
Pri. – Pri. (PWB Trace at between 2500 1.8 (1.5) 5.3
Capacitor (C13) and L2 of Terminal
Block (TB1)) (3+)
Pri. – Pri. (PWB Trace at between 2500 1.8 (1.5) 3.1
Capacitors (C11, C12) and L2 of
Terminal Block (TB1)) (3+)
Pri. – Pri. (PWB Trace T to R at 2500 1.8 (1.5) 4.0
Inductor (L11)) (+)
Basic/supplementary: -- -- --
Pri. – Gnd (PWB Trace at Capacitor 2500 1.8 (1.5) 7.5
(C14, C16) (+))
Pri. – Gnd (PWB Trace at between 2500 1.8 (1.5) 9.0
FG of Terminal Block (TB2) and N of
Terminal Block (TB2) (3+))
Reinforced: -- -- --
Pri. - Sec. (Screw of TR304 to T301 2500 3.5 (3.0) 7.0
core) (2+)
Pri. - Sec. (Wire of Internal fan to 2500 3.5 (3.0) 15.2
T301 core) (2+)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 75 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Pri. - Sec. (T702 core to output 2500 3.5 (3.0) 11.1


terminal (2+)
Pri. - Sec. (TR702 to output terminal) 2500 3.5 (3.0) 10.5
(2+)
Pri. - Sec. (PWB Trace at between 2500 3.5 (3.0) 7.0
TB211 and TB112) (+)
Pri. - Sec. (PWB Trace at between 2500 3.5 (3.0) 8.5
PS1/+V out and L2 of Terminal Block
(TB1)) (3+)
Pri. - Sec. (PWB Trace at PC204 3pin 2500 3.5 (3.0) 6.2
to T301 6, 7, 8pin) (2+)
Pri. - Sec. (PWB Trace at C125 to 2500 3.5 (3.0) 8.8
T301 9, 10, 11pin (2+)
Pri. - Sec. (PWB Trace at L311 pin to 2500 3.5 (3.0) 8.5
T301 3, 4, 5pin (2+)
Pri. - Sec. (PWB Trace at Optical 2500 3.5 (3.0) 6.5
Isolators (PC201, PC203, PC204,
PC331, PC332) (2+)
Pri. - Sec., (PWB Trace at between 2500 3.5 (3.0) 7.0
TR302 and T301 3, 4, 5pin (2+)
Pri. - Sec., (PWB Trace at C744 to 2500 3.5 (3.0) 6.7
T701 1pin (2+)
Pri. - Sec., (PWB Trace at TR702 to 2500 3.5 (3.0) 10.0
Output terminal trace (2+)
Supplementary information:
(+) FETA7000T-144/-48
(2+) FETA2500BA-48
(3+) FETA7000ST-144/-48
The value in the above table is the required clearance of operated at up to 3000 m sea level. The multiplication
factors of table 17 applied. For operation up to 2000 m sea level, see the value in the parentheses.

5.4.2.4 TABLE: Clearances based on electric strength test N/A


Test voltage applied between: Required cl Test voltage (kV) Breakdown
(mm) peak/ r.m.s. / d.c. Yes / No
-- -- -- --
Supplementary information: --

5.4.4.2, TABLE: Distance through insulation measurements P


5.4.4.5 c)
5.4.4.9
Distance through Peak voltage Frequency Material Required DTI DTI
insulation di at/of: (V) (kHz) (mm) (mm)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 76 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Basic: Insulation sheet 1050 1340 PC (AGC -- 0.25


between Main PWB and (Ep: 63.6 kV/mm, Ef: (Kr: 0.17) Polycarbonat (Required Vw:
Chassis 10.812 kV, Vw: 2.703 e Co., Ltd., 1.26 kV)
kV) Type (1.050 x 1.2)
CARBOGLAS
S CFR230B)
Supplementary: 1050 1340 Silicone 0.4 0.56
Insulation tube for CN31, (Ep: 14 kV/mm, Ef: 2.38 (Kr: 0.17) rubber (Required Vw:
CN32 and CN33 kV, Vw: 1.332 kV) (Nikkan 1.26 kV)
Industries (1.050 x 1.2)
Co., Ltd.,
Type E-651U-
1)
Supplementary information: --

5.4.9 TABLE: Electric strength tests P


Test voltage applied between: Voltage shape Test voltage (V) Breakdown
(AC, DC) Yes / No
Functional:
-- -- -- --
Basic/supplementary: -- -- --
Primary / Ground DC 3393 (#1) No
Reinforced: -- -- --
Primary / Secondary DC 4243 (#2) No
Routine Tests: N/A N/A N/A
Supplementary information:
(#1) Required voltage is 2500 Vpk. Test was carried out under severer condition due to applicant’s request.
(#2) Required voltage is 4000 Vpk. Test was carried out under severer condition due to applicant’s request.

5.5.2.2 TABLE: Stored discharge on capacitors P


Supply Voltage (V), Hz Test Operating Switch Measured Voltage ES Classification
Location Condition position (after 2 seconds)
(N, S) On or off
Model FETA7000T-144 -- -- -- -- --
264 Vac, 60 Hz Phase R N N/A 0.719 V ES1
line to S line
264 Vac, 60 Hz Phase S line N N/A 0.844 V ES1
to T line
264 Vac, 60 Hz Phase T line N N/A 0.50 V ES1
to R line
264 Vac, 60 Hz Phase R N N/A 45.47 V ES1
line to
Ground
264 Vac, 60 Hz Phase S line N N/A 46.34 V ES1
to Ground

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 77 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

264 Vac, 60 Hz Phase T line N N/A 50.44 V ES1


to Ground
264 Vac, 60 Hz Phase to S (#1) -- -- --
Neutral
Model FETA7000ST- -- -- -- -- --
144
457 Vac, 60 Hz Phase L1 to N N/A 1.187 V ES1
L2
457 Vac, 60 Hz Phase L2 to N N/A 1.563 V ES1
L3
457 Vac, 60 Hz Phase L3 to N N/A 1.219 V ES1
L1
457 Vac, 60 Hz Phase L1 to N N/A 1.258 V ES1
Ground
457 Vac, 60 Hz Phase L2 to N N/A 1.031 V ES1
Ground
457 Vac, 60 Hz Phase L3 to N N/A 1.50 V ES1
Ground
457 Vac, 60 Hz Phase L1 to N N/A 1.469 V ES1
Neutral
457 Vac, 60 Hz Phase L2 to N N/A 0.532 V ES1
Neutral
457 Vac, 60 Hz Phase L3 to N N/A 0.532 V ES1
Neutral
457 Vac, 60 Hz Phase N N/A 0.065 V ES1
Neutral to
Ground
457 Vac, 60 Hz Phase to S (#1) -- -- --
Neutral
Supplementary information:
X-capacitors installed for testing are: For model FETA7000T series: 0.68μF (C101 of model FETA2500BA-48),
0.68μF (C11, C12, C13 of model FETA7000T series), Total 1.36μF
For model FETA7000ST series: 0.68μF (C101 of model FETA2500BA-48), 0.34μF (C11, C12, C13, C14), Total
1.02μF
☒ bleeding resistor rating: 56 kohm, 1/4 W (R102, R103, R104, R105, R106, R107, R108, R109, R110, R111
R112, R113 connected in series) the above resistors installed in model FETA2500BA-48.
☐ ICX: :
Notes:
A. Test Location:
Phase to Neutral; Phase to Phase; Phase to Earth; and/or Neutral to Earth
B. Operating condition abbreviations:
N – Normal operating condition (e.g., normal operation, or open fuse); S –Single fault condition
(#1): No test was performed. See Clause G10.1.

5.6.6.2 TABLE: Resistance of protective conductors and terminations N/A

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 78 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Accessible part Test current Duration Voltage drop Resistance


(A) (min) (V) (Ω)
FG terminal of TB2 to Cover 100 4 0.301 0.003
Supplementary information:
This test data is for reference purpose only.

5.7.2.2, TABLE: Earthed accessible conductive part P


5.7.4
Supply voltage .............................................................. : 264 Vac, 60 Hz —
Location Test conditions specified in 6.1 of Touch current
IEC 60990 or Fault Condition No (mA)
in IEC 60990 clause 6.2.2.1
through 6.2.2.8, except for 6.2.2.7
FG Terminal Model: FETA7000T-144 / Delta
--
system
1, switch e open, Phase R line (For fig.4) 2.64
connected to FG, Capacitor (C14)
disconnected (For fig.5) 2.66

1, switch e open, Phase S line (For fig.4) 2.64


connected to FG, Capacitor (C14)
disconnected (For fig.5) 2.65

1, switch e open, Phase T line (For fig.4) 2.98


connected to FG, Capacitor (C14)
disconnected (For fig.5) 2.99

1, switch e open, Phase R line (For fig.4) 2.61


connected to FG, Capacitor (C15)
disconnected (For fig.5) 2.60

1, switch e open, Phase S line (For fig.4) 2.95


connected to FG, Capacitor (C15)
disconnected (For fig.5) 2.94

1, switch e open, Phase T line (For fig.4) 2.62


connected to FG, Capacitor (C15)
disconnected (For fig.5) 2.62

1, switch e open, Phase R line (For fig.4) 2.64


connected to FG, Capacitor (C16)
disconnected (For fig.5) 2.66

1, switch e open, Phase S line (For fig.4) 2.60


connected to FG, Capacitor (C16)
disconnected (For fig.5) 2.62

1, switch e open, Phase T line (For fig.4) 2.60


connected to FG, Capacitor (C16)
disconnected (For fig.5) 2.60

2* N/A
3 N/A
(For fig.4)
4, Phase R line open, Phase R switch e close:
line connected to FG 0.001, switch e
open: 0.063,

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 79 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

(For fig.5)
switch e close:
0.001, switch e
open: 0.063
(For fig.4)
switch e close:
0.001, switch e
4, Phase R line open, Phase S open: 2.524,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.524
(For fig.4)
switch e close:
0.001, switch e
4, Phase R line open, Phase T open: 2.528,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.534
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase R open: 2.556,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.550
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase S open: 0.080,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 0.080
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase T open: 2.546,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.553
(For fig.4)
switch e close:
0.001, switch e
4, Phase T line open, Phase R open: 2.522,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.530
4, Phase T line open, Phase S (For fig.4)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 80 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

line connected to FG switch e close:


0.001, switch e
open: 2.544,
(For fig.5)
switch e close:
0.001, switch e
open: 2.539
(For fig.4)
switch e close:
0.001, switch e
4, Phase T line open, Phase T open: 0.067,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 0.067
Model: FETA7000T-144 / Star
--
system
(For fig.4)
Normal: 0.26,
1, switch e open, Capacitor (C16) Reverse: 0.26,
disconnected (For fig.5)
Normal: 0.27,
Reverse: 0.25
(For fig.4)
Normal: 0.27,
1, switch e open, Capacitor (C15) Reverse: 0.25,
disconnected (For fig.5)
Normal: 0.28,
Reverse: 0.26
(For fig.4)
Normal: 0.25,
1, switch e open, Capacitor (C14) Reverse: 0.24,
disconnected (For fig.5)
Normal: 0.26,
Reverse: 0.25
2* N/A
3 N/A
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.37, Reverse:
1.40,
4, Phase R line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.40

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 81 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.40,
4, Phase S line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.40
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.37, Reverse:
1.41,
4, Phase T line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.41
5 N/A
6 N/A
8 N/A
Model: FETA7000ST-144 / Star
--
system
(For fig.4)
Normal: 0.12,
1, switch e open, Capacitor (C15) Reverse: 0.12,
disconnected (For fig.5)
Normal: 0.14,
Reverse: 0.14
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
4, Phase L1 line open open: Normal:
0.66, Reverse:
0.67,
(For fig.5)
switch e close:
Normal: 0.001,

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 82 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Reverse:
0.001, switch e
open: Normal:
0.67, Reverse:
0.66
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66,
4, Phase L2 line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66,
4, Phase L3 line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66
5 N/A
6 N/A
8 N/A
Supplementary Information:
Notes:
[1] Supply voltage is the anticipated maximum Touch Voltage
[2] Earthed neutral conductor [Voltage differences less than 1% or more]
[3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3
[4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable.
[5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g., appliance coupler)
provided.

6.2.2 TABLE: Electrical power sources (PS) measurements for classification P


Max Power after 3 Max Power after 5 PS
Source Description Measurement
s s*) Classification

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 83 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

48 Vdc output Power (W) .... : -- 9008.2


of model
A VA (V)........... : -- 52.8 PS3
FETA7000T-
48 IA (A) ............ : -- 184.0
144 Vdc Power (W) .... : -- 9204.0
output of
B model VA (V)........... : -- 158.4 PS3
FETA7000T- IA (A) ............ :
144 -- 59.0

48 Vdc output Power (W) .... : -- 9176.7


of model VA (V)........... :
C
FETA7000ST-
-- 52.8 PS3
48 IA (A) ............ : -- 176.4
144 Vdc Power (W) .... : -- 9122.1
output of
D model VA (V)........... : -- 158.4 PS3
FETA7000ST- IA (A) ............ :
144 -- 58.4
AUX output of Power (W) .... : -- 14.0 (#)
model
VA (V)........... : -- 1.45 (#)
FETA7000T
E PS2
series and IA (A) ............ :
FETA7000ST -- 0.4 (#)
series
Supplementary Information:
(*) Measurement taken only when limits at 3 seconds exceed PS1 limits
(#) These results are referred to the results of the AUX output of Model FETA2500BA-48, Because the AUX
outputs of Models FETA7000T series and FETA7000ST series are identical to the circuits of the AUX output of
Model FETA2500BA-48.

6.2.3.1 TABLE: Determination of Potential Ignition Sources (Arcing PIS) N/A


Open circuit
voltage Measured r.m.s
After 3 s current Calculated value Arcing PIS?
Location (Vp) (Irms) (Vp x Irms) Yes / No
-- -- -- -- --
Supplementary information:

An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the product of
the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than 15.
All circuits are considered as PIS.

6.2.3.2 TABLE: Determination of Potential Ignition Sources (Resistive PIS) N/A


Measured Measured Protective Circuit,
Operating Resistive
wattage or wattage or Regulator, or
Condition PIS?
Circuit Location (x-y) VA VA PTC Operated?
(Normal / Describe
During first After 30 s (W Yes / No Yes/No
Single Fault)
30 s (W / VA) / VA) (Comment)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 84 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

-- -- -- -- -- --
Supplementary Information:

A combination of voltmeter, VA and ammeter IA may be used instead of a wattmeter.


If a separate voltmeter and ammeter are used, the product of (VA x IA) is used to determine Resistive PIS
classification.
A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under single
fault conditions has either a power exceeding 100 W measured immediately after the introduction of the fault if
electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15 W measured 30
s after introduction of the fault.
All circuits are considered as PIS.

8.5.5 TABLE: High Pressure Lamp N/A


Description Values Energy Source Classification
Lamp type..................................................... : -- —
Manufacturer................................................. : -- —
Cat no........................................................... : -- —
Pressure (cold) (MPa) ................................... : -- MS_
Pressure (operating) (MPa) ........................... : -- MS_
Operating time (minutes) ............................... : -- —
Explosion method.......................................... : -- —
Max particle length escaping enclosure (mm) . : -- MS_
Max particle length beyond 1 m (mm) ............ : -- MS_
Overall result ................................................. : --
Supplementary information:
No high pressure lamp used.

B.2.5 TABLE: Input test P


U (V) I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
-- Phase T, -- -- -- -- Phase T, --
S, R S, R
FETA7000T- -- -- -- -- -- -- --
48
Power -- -- -- -- -- -- 3 PHASE, Star
Source system
Connection
200 22.5, 22.7 -- -- (+) 22.5, 50Hz, 48V, 148.2A
22.5, 22.5,
23.0 23.0
200 22.5, 22.7 -- -- (+) 22.5, 60Hz, 48V, 148.2A
22.5, 22.5,
23.0 23.0

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 85 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

240 19.0, 22.7 -- -- (+) 19.0, 50Hz, 48V, 148.2A


19.0, 19.0,
19.0 19.0
240 19.0, 22.7 -- -- (+) 19.0, 60Hz, 48V, 148.2A
19.0, 19.0,
19.0 19.0
200 22.5, 22.7 -- -- (+) 22.5, 50Hz, 52.8V,
22.5, 22.5, 134.73A
23.0 23.0
200 22.5, 22.7 -- -- (+) 22.5, 60Hz, 52.8V,
22.5, 22.5, 134.73A
23.0 23.0
240 19.0, 22.7 -- -- (+) 19.0, 50Hz, 52.8V,
19.0, 19.0, 134.73A
19.0 19.0
240 19.0, 22.7 -- -- (+) 19.0, 60Hz, 52.8V,
19.0, 19.0, 134.73A
19.0 19.0
Power -- -- -- -- -- -- 3 PHASE, Delta
Source system, Gnd
Connection connected to R line.
200 22.5, 22.7 -- -- (+) 22.5, 50Hz, 48V, 148.2A
22.5, 22.5,
22.5 22.5
200 22.5, 22.7 -- -- (+) 22.5, 60Hz, 48V, 148.2A
22.5, 22.5,
22.5 22.5
240 19.0, 22.7 -- -- (+) 19.0, 50Hz, 48V, 148.2A
19.0, 19.0,
19.0 19.0
240 19.0, 22.7 -- -- (+) 19.0, 60Hz, 48V, 148.2A
19.0, 19.0,
19.0 19.0
200 22.5, 22.7 -- -- (+) 22.5, 50Hz, 52.8V,
22.5, 22.5, 134.73A
22.5 22.5
200 22.5, 22.7 -- -- (+) 22.5, 60Hz, 52.8V,
22.5, 22.5, 134.73A
22.5 22.5
240 19.0, 22.7 -- (+) 19.0, 50Hz, 52.8V,
19.0, 19.0, 134.73A
19.0 19.0
240 19.0, 22.7 -- -- (+) 19.0, 60Hz, 52.8V,
19.0, 19.0, 134.73A
19.0 19.0

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 86 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

FETA7000T- -- -- -- -- -- -- --
144
Power -- -- -- -- -- -- 3 PHASE, Star
Source system
Connection
200 24.5, 23.9 -- -- (+) 24.5, 50 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
200 24.5, 23.9 -- -- (+) 24.5, 60 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
200 24.0, 23.9 -- -- (+) 24.0, 50 Hz, 158.4 V, 47.28
24.5, 24.5, A
24.0 24.0
200 24.0, 23.9 -- -- (+) 24.0, 60 Hz, 158.4 V, 47.28
24.5, 24.5, A
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
Power -- -- -- -- -- -- 3 PHASE, Delta
Source system, Gnd
Connection connected to R line.
200 24.5, 23.9 -- -- (+) 24.5, 50 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
200 24.5, 23.9 -- -- (+) 24.5, 60 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 87 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

200 24.0, 23.9 -- -- (+) 24.0, 50 Hz, 158.4 V, 47.28


24.5, 24.5, A
24.0 24.0
200 24.0, 23.9 -- -- (+) 24.0, 60 Hz, 158.4 V, 47.28
24.5, 24.5, A
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
-- Phase -- -- -- -- Phase --
L1, L2, L1, L2,
L3 L3
FETA7000ST -- -- -- -- -- -- --
-48
Power -- -- -- -- -- -- 3 PHASE, Star
Source (3/N/PE) system
Connection
346/200 13.0, 13.2 -- -- (+) 13.0, 50Hz, 48V, 148.2A
13.0, 13.0,
13.0 13.0
346/200 13.0, 13.2 -- -- (+) 13.0, 60Hz, 48V, 148.2A
13.0, 13.0,
13.0 13.0
415/240 10.8, 13.2 -- -- (+) 10.8, 50Hz, 48V, 148.2A
10.8, 10.8,
10.8 10.8
415/240 10.8, 13.2 -- -- (+) 10.8, 60Hz, 48V, 148.2A
10.8, 10.8,
10.8 10.8
346/200 13.0, 13.2 -- -- (+) 13.0, 50Hz, 52.8V,
13.0, 13.0, 134.73A
13.0 13.0
346/200 13.0, 13.2 -- -- (+) 13.0, 60Hz, 52.8V,
13.0, 13.0, 134.73A
13.0 13.0
415/240 10.8, 13.2 -- -- (+) 10.8, 50Hz, 52.8V,
10.8, 10.8, 134.73A
10.8 10.8
415/240 10.8, 13.2 -- -- (+) 10.8, 60Hz, 52.8V,
10.8, 10.8, 134.73A
10.8 10.8

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 88 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

FETA7000ST -- -- -- -- -- -- --
-144
Power -- -- -- -- -- -- 3 PHASE, Star
Source (3/N/PE) system
Connection
346/200 13.6, 13.8 -- -- (+) 13.6, 50 Hz, 144 V, 52 A
13.8, 13.8,
13.8 13.8
346/200 13.6, 13.8 -- -- (+) 13.6, 60 Hz, 144 V, 52 A
13.8, 13.8,
13.8 13.8
415/240 11.4, 13.8 -- -- (+) 11.4, 50 Hz, 144 V, 52 A
11.6, 11.6,
11.6 11.6
415/240 11.4, 13.8 -- -- (+) 11.4, 60 Hz, 144 V, 52 A
11.6, 11.6,
11.6 11.6
346/200 13.6, 13.8 -- -- (+) 13.6, 50 Hz, 158.4 V, 47.28
13.8, 13.8, A
13.8 13.8
346/200 13.6, 13.8 -- -- (+) 13.6, 60 Hz, 158.4 V, 47.28
13.8, 13.8, A
13.8 13.8
415/240 11.2, 13.8 -- -- (+) 11.2, 50 Hz, 158.4 V, 47.28
11.4, 11.4, A
11.4 11.4
415/240 11.2, 13.8 -- -- (+) 11.2, 60 Hz, 158.4 V, 47.28
11.4, 11.4, A
11.4 11.4
Supplementary information:
(+) Branch circuit breaker, Rated 50A.

B.3 TABLE: Abnormal operating condition tests P


Ambient temperature (C) ........................................................... : See below. 
Power source for EUT: Manufacturer, model/type, output rating .. : NF Electronic Instruments 
ES180000W, Output 18KVA
Component No. Abnormal Supply Test time Fuse Fuse T- Temp. Observation
Condition voltage, (V) (ms) no. current, couple (C)
(A)
Model -- -- -- -- -- -- -- --
FETA7000T-48

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 89 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

52.8V output Short 264 Vac 1 second (+) -- (+) (+) Unit shut down no
/60Hz (2+) damaged.
NB, NC, NT,
Ambient: 25 °C
52.8V output Overload 264 Vac 7 hours, (+) 22.0, (+) (+) Maximum
/60Hz (2+) 21 21.5, continuous
temperature was
minutes. 22.0 obtained at 52.07V,
173A load.
T301 coil (Sec.
side) of PS1:
101 °C.
T701 coil of PS1:
81 °C.
T301 coil (Sec.
side) of PS2:
107 °C.
T701 coil of PS2:
82 °C.
T301 coil (Sec.
side) of PS3:
101 °C.
T701 coil of PS3:
80 °C.
Then temperature
decreased when
further loaded over
173 A load.
NB, NC, NT,
Ambient: 25°C
Model -- -- -- -- -- -- -- --
FETA7000T-
144
158.4V output Short 264 Vac 1 (+) -- (+) (+) Unit shut down no
/60Hz (2+) seccond damaged.
NB, NC, NT,
Ambient: 25 °C

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 90 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

158.4V output Overload 264 Vac 4 hours, (+) 22.0, (+) (+) Maximum
/60Hz (2+) 48 22.0, continuous
minutes. 22.0 temperature was
obtained at 157.6
V, 56.8 A. load.
T301 coil (Sec.
side) of PS1:
101 °C.
T701 coil of PS1:
81 °C.
T301 coil (Sec.
side) of PS2:
108 °C.
T701 coil of PS2:
84 °C.
T301 coil (Sec.
side) of PS3:
100 °C.
T701 coil of PS3:
80 °C.
Then temperature
decreased when
further loaded over
56.8 A load.
NB, NC, NT,
Ambient: 26 °C
Supplementary information:
Test table is provided to record abnormal and fault conditions for all applicable energy sources including
Thermal burn injury. Column “Abnormal/Fault.” Specify if test condition by indicating “Abnormal” then the
condition for a Clause B.3 test or “Single Fault” then the condition for Clause B.4.
(+) Branch circuit breaker, Rated 50A.
(2+) Power Source Connection: 3 PHASE, Delta System,
CT - Constant temperatures were obtained
NB - No indication of dielectric breakdown
NC - Cheesecloth remained intact
NT - Tissue paper remained intact
Test performed on models FETA7000T-144 and FETA7000T-48 representative of models FETA7000ST-144
and FETA7000ST-48 because the difference between each other is only the difference between the primary
part and the supply power source at a level that is not affected by the above test results.

B.4 TABLE: Fault condition tests P


Ambient temperature (C) ...........................................................: See below. 
Power source for EUT: Manufacturer, model/type, output rating ..: See below. 
Component No. Fault Supply Test time Fuse Fuse T-couple Temp. Observation
Condition voltage, (V) (ms) no. current, (A) (C)

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 91 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Component -- -- -- -- -- -- -- --
Failure Test
Model -- -- -- -- -- -- -- --
FETA7000T-144
PC481 (Primary Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
side) /60Hz (2+) minutes 18.5 normal.
NB, NC ,NT,
Ambient:
25 °C
PC481 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
PC482 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Primary side) /60Hz (2+) minutes 18.5 normal.
NB, NC, NT,
Ambient:
25 °C
PC482 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
PC461 Short 264Vac 1 second (+) -- -- -- Unit shit down
(Primary side) /60Hz (2+) no damaged.
NB, NC, NT,
Ambient:
25 °C
PC461 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
TR491 Short 264Vac 15 (+) 15.0, 17.0, -- -- Output down:
(C to E) /60Hz (2+) minutes 15.0 144V, 52A
>124V 52A.
Unit kept the
operation
aftre short
test.
NB, NC, NT,
Ambient:
25 °C

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 92 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

TR491 Short 264Vac 15 (+) 15.0, 17.0, -- -- Output down:


(E to B) /60Hz (2+) minutes 15.0 144V, 52A
>128V 52A.
Unit kept the
operation
aftre short
test.
NB, NC, NT,
Ambient:
25 °C
Abnormal -- -- -- -- -- -- -- --
Operation Test
Model -- -- -- -- -- -- -- --
FETA7000T-
144
FAN of PS2 Stalled 180 Vac 5 (+) -- -- -- After 5
/60Hz (2+) seconds seconds. unit
shut down no
damaged.
NB, NC, NT,
Ambient:
25 °C
Phase open (S opened 180 Vac 1 second (+) -- -- -- Unit shut
line) /60Hz (2+) down no
damaged.
NB, NC, NT,
Ambient:
25 °C
Phase open (S opened 180 Vac 1 second (+) -- -- -- Unit shut
line) /60Hz (3+) down no
damaged.
NB, NC, NT,
Ambient:
25 °C
Supplementary information:
(+) Branch circuit breaker, Rated 50A.
(2+) Power Source Connection: 3 PHASE, Delta System,
(3+) Power Source Connection: 3 PHASE, Star System,
CT - Constant temperatures were obtained
NB - No indication of dielectric breakdown
NC - Cheesecloth remained intact
NT - Tissue paper remained intact
Test performed on models FETA7000T-144 and FETA7000T-48 representative of models FETA7000ST-144
and FETA7000ST-48 because the difference between each other is only the difference between the primary
part and the supply power source at a level that is not affected by the above test results.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 93 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Annex M TABLE: Batteries N/A


The tests of Annex M are applicable only when appropriate battery data is not available N/A
Is it possible to install the battery in a reverse polarity position? ........................ : N/A
Non-rechargeable batteries Rechargeable batteries
Discharging Un- Charging Discharging Reversed
intentional charging
charging
Meas. Manuf. Meas. Manuf. Meas. Manuf. Meas. Manuf.
current Specs. current Specs. current Specs. current Specs.
Max. current -- -- -- -- -- -- -- -- --
during normal
condition
Max. current -- -- -- -- -- -- -- -- --
during fault
condition

Test results: -- Verdict


- Chemical leaks -- N/A
- Explosion of the battery -- N/A
- Emission of flame or expulsion of molten metal -- N/A
- Electric strength tests of equipment after completion of tests -- N/A
Supplementary information:
No battery used.

Annex M.4 TABLE: Additional safeguards for equipment containing secondary lithium N/A
batteries

Battery/Cell Measurements
Test conditions Observation
No.
U I (A) Temp (C)
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault –SC/OC -- -- -- --
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault – SC/OC -- -- -- --
Supplementary Information:

Charging at Observation Charging at Observation


Battery
Tlowest Thighest
identification
(C) (C)
-- -- -- -- --
Supplementary Information:
No battery used.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 94 of 95 Report No. 4788327671
IEC 62368-1 (ed.2) & IEC 60065 (ed.8) & IEC 60950-1 (ed.2), am1; am2
Clause Requirement + Test Result - Remark Verdict

Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) P
Note: Measured UOC (V) with all load circuits disconnected:
Output Components Uoc (V) Isc (A) S (VA)
Circuit
Meas. Limit Meas. Limit
-- -- -- -- -- -- --
Supplementary Information:
SC=Short circuit, OC=Open circuit
See Annex Q.

T.2, T.3, TABLE: Steady force test N/A


T.4, T.5
Part/Location Material Thickness Force Test Duration Observation
(mm) (N) (sec)
-- -- -- -- -- --
Supplementary information:
Building-in component.

T.6, T.9 TABLE: Impact tests N/A


Part/Location Material Thickness Vertical Observation
(mm) distance (mm)
-- -- -- -- --
Supplementary information:
Building-in component.

T.7 TABLE: Drop tests N/A


Part/Location Material Thickness Drop Height Observation
(mm) (mm)
-- -- -- -- --
Supplementary information:
Building-in component.

T.8 TABLE: Stress relief test N/A


Part/Location Material Thickness Oven Duration Observation
(mm) Temperature (h)
(C)
-- -- -- -- -- --
Supplementary information:
Building-in component.

TRF No. IEC62368_1&IEC60065&IEC60950_1A


Page 95 of 95 Report No. 4788327671

List of test equipment used:


A completed list of used test equipment shall be provided in the Test Reports when a Manufacturer Testing
Laboratory according to TMP/CTF stage 1 or WMT/CTF stage 2 procedure has been used.

Clause Measurement / Testing / measuring equipment / Range used Calibration


testing material used date
-- -- -- -- --
Page 1 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 62368-1


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(Audio/video, information and communication technology equipment Part 1: Safety requirements)
Differences according to ............... : EN 62368-1:2014
Attachment Form No. .................... : EU_GD_IEC62368_1B
Attachment Originator .................. : Intertek Semko AB
Master Attachment ........................ : Date (2015-08)
Copyright © 2015 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE)

CENELEC COMMON MODIFICATIONS (EN) P


1 NOTE Z1 P
4.Z1 Protective devices included as integral parts of Building-in component. N/A
the equipment or as parts of the building
No direct connection to mains.
installation:
Final compliance to be
evaluated in end-product.
a) Included as parts of the equipment N/A
b) For components in series with the mains; by N/A
devices in the building installation
c) For pluggable type B or permanently connected; N/A
by devices in the building installation
5.4.2.3.2.4 Interconnection with external circuit Building-in component. N/A
10.2.1 Additional requirements in 10.5.1 N/A
10.5.1 RS1 compliance measurement conditions No X-ray radiation. N/A
10.6.2.1 EN 71-1:2011, 4.20 and methods and distances No acoustic energy sources. N/A
10.Z1 Non-ionizing radiation from radio frequencies in N/A
the range 0 to 300 GHz
G.7.1 NOTE Z1 N/A

ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) P


4.1.15 Denmark, Finland, Norway and Sweden: Building-in component. N/A
Class I pluggable equipment type A marking
4.7.3 United Kingdom: No direct plug-in. N/A
Torque test socket-outlet BS 1363, and the plug
part BS 1363.
5.2.2.2 Denmark: N/A
Warning for high touchcurrent
5.4.11.1 Finland and Sweden: Not intended for connection to N/A
and Separation of the telecommunication network telecommunication network.
Annex G from earth
Page 2 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

5.5.2.1 Norway: Considered. P


Capacitors rated for the applicable line-to-line
voltage (230 V).
5.5.6 Finland, Norway and Sweden: Considered for discharged P
Resistors used as basic safeguard or bridging resistors (see cl. G.10).
basic insulation comply with G.10.1 and G.10.2.
5.6.1 Denmark: Building-in component. N/A
Protection for pluggable equipment type A;
integral part of the equipment
5.6.4.2.1 Ireland and United Kingdom: N/A
The protective current rating is taken to be 13 A
5.6.5.1 Ireland and United Kingdom: Building-in component. N/A
Conductor sizes of flexible cords to be accepted No power supply cord.
by terminals for equipment rated 10 A to 13 A
5.7.5 Denmark: Building-in component. N/A
The installation instruction affixed to the
equipment if high protective conductor current
5.7.6.1 Norway and Sweden: Building-in component. N/A
Television distribution system isolation text in
user manual
5.7.6.2 Denmark: Building-in component. N/A
Warning for high touch current
B.3.1 Ireland and United Kingdom: No direct plug-in. N/A
and Tests conducted using an external miniature
B.4 circuit breaker or protective devices included as
an integral part of the direct plug-in equipment
G.4.2 Denmark: Building-in component. N/A
Appliances rated ≤13 A provided with a plug No power supply cord.
according to DS 60884-2-D1:2011.
Class I equipment provided with socket-outlets N/A
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having rated >13 A N/A
or poly-phase equipment provided with a supply
cord with a plug, plug in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or
EN 60309-2.
Mains socket outlets intended for providing power N/A
to Class II apparatus rated 2,5 A in accordance
with DS 60884-2-D1:2011 standard sheet DKA 1-
4a.
Other current rating socket outlets in compliance N/A
with Standard Sheet DKA 1-3a or DKA 1-1c.
Mains socket-outlets with earth in compliance N/A
with DS 60884-2-D1:2011 Standard Sheet DK 1-
3a, DK 1-1c, DK1-1d, DK 1-5a or DK 1-7a
G.4.2 United Kingdom: No direct plug-in. N/A
The plug part of direct plug-in equipment
assessed to BS 1363
Page 3 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

G.7.1 United Kingdom: Building-in component. N/A


Equipment fitted with a ‘standard plug’ in
No power supply cord and
accordance with the Plugs and Sockets etc
plug.
(Safety) Regulations 1994, Statutory Instrument
1994 No. 1768
G.7.1 Ireland: Building-in component. N/A
Apparatus provided with a plug in accordance
No power supply cord and
with Statutory Instrument 525: 1997, “13 A Plugs
plug.
and Conversion Adapters for Domestic Use
G.7.2 Ireland and United Kingdom: Building-in component. N/A
A power supply cord for equipment which is rated No power supply cord.
over 10 A and up to and including 13 A.

ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A


10.5.2 Germany: No cathode ray tube. N/A
Cathode ray tube intended for the display of
visual images, authorization or application of type
approval and marking.
F.1 Italy: No such equipment. N/A
The power consumption in Watts (W) indicated on
TV receiver and in instruction for use
TV receivers provided with an instruction for use, N/A
schematic diagrams and adjustments procedure
in Italian language.
Marking for controls and terminals in Italian N/A
language.
Conformity declaration according to the above N/A
requirements in the instruction manual
First importers of TV receivers manufactured N/A
outside EEC previous conformity certification to
the Italian Post Ministry and Certification number
on the backcover.
Page 4 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 62368-1 2th Ed.


U.S.A. NATIONAL DIFFERENCES
Audio/video, information and communication technology equipment – Part 1: Safety requirements
Differences according to ............... : CSA/UL 62368-1:2014
Attachment Form No. .................... : US&CA_ND_IEC623681B
Attachment Originator .................. : UL(US)
Master Attachment ........................ : Date 2015-06
Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

IEC 62368-1 - US and Canadian National Differences


Special National Conditions based on Regulations and Other National Differences

1.1 All equipment is to be designed to allow Considered. P


installation according to the National Electrical
Code (NEC), ANSI/NFPA 70, the Canadian
Electrical Code (CEC), Part I, CAN/CSA C22.1,
and when applicable, the National Electrical
Safety Code, IEEE C2.
Also, for such equipment marked or otherwise
identified, installation is allowed per the
Standard for the Protection of Information
Technology Equipment, ANSI/NFPA 75.
1.4 Additional requirements apply to some forms of No such equipment. N/A
power distribution equipment, including sub-
assemblies.
4.1.17 For lengths exceeding 3.05 m, external No interconnecting cable N/A
interconnecting flexible cord and cable provided.
assemblies are required to be a suitable cable
type (e.g., DP, CL2) specified in the NEC.
For lengths 3.05 m or less, external N/A
interconnecting flexible cord and cable
assemblies that are not types specified in the
NEC generally are required to have special
construction features and identification
markings.
4.8 Lithium coin / button cell batteries have modified No lithium coin / button cell N/A
special construction and performance batteries.
requirements.
5.6.3 Protective earthing conductors comply with the Building-in component. N/A
minimum conductor sizes in Table G.5, except
as required by Table G.7ADV.1 for cord
connected equipment, or Annex DVH for
permanently connected equipment
Page 5 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

5.7.7 Equipment intended to receive No such equipment. N/A


telecommunication ringing signals complies with
a special touch current measurement tests.
6.5.1 PS3 wiring outside a fire enclosure complies Building-in component. N/A
with single fault testing in B.4, or be current
limited per one of the permitted methods.
Annex F Output terminals provided for supply of other Building-in component. N/A
(F.3.3.8) equipment, except mains, supply are marked
with a maximum rating or references to which
equipment it is permitted to be connected.
Annex G Permanent connection of equipment to the Building-in component. N/A
(G.7.1) mains supply by a power supply cord is not
permitted, except for certain equipment, such as
ATMs.

Annex G Power supply cords are required to have Building-in component. N/A
(G.7.3) attachment plugs rated not less than 125 No power supply cord.
percent of the rated current of the equipment.
Flexible power supply cords are required to be N/A
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.

Annex G Minimum cord length is required to be 1.5 m, Building-in component. N/A


(G.7.5) with certain constructions such as external No power supply cord.
power supplies allowed to consider both input
and output cord lengths into the requirement.
Power supply cords are required to be no longer
than 4.5 m in length if used in ITE Rooms.
Annex H.2 Continuous ringing signals under normal No ringing signals generated. N/A
operating conditions up to 16 mA only are
permitted if the equipment is subjected to
special installation and performance restrictions.

Annex H.4 For circuits with other than ringing signals and N/A
with voltages exceeding 42.4 Vpeak or 60 V d.c.,
the maximum acceptable current through a
2000 ohm resistor (or greater) connected across
the voltage source with other loads
disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
Annex M Battery packs for stationary applications comply No battery pack. N/A
with special component requirements.
Page 6 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex DVA Equipment intended for use in spaces used for Building-in component. N/A
(1) environmental air are subjected to special
flammability requirements for heat and visible
smoke release.
For ITE room applications, automated N/A
information storage systems with combustible
3
media greater than 0.76 m (27 cu ft) have a
provision for connection of either automatic
sprinklers or a gaseous agent extinguishing
system with an extended discharge.
Consumer products designed or intended N/A
primarily for children 12 years of age or younger
are subject to additional requirements in
accordance with U.S. & Canadian Regulations.

Baby monitors additionally comply with ASTM N/A


F2951, Consumer Safety Specification for Baby
Monitors.

Annex DVA For Pluggable Equipment Type A, the protection Building-in component. N/A
(5.6.3) in the installation is assumed to be 20A.
Annex DVA The maximum quantity of flammable liquid No flammable liquid used. N/A
(6.3) stored in equipment complies with NFPA 30.

Annex DVA For ITE room applications, enclosures with Building-in component. N/A
(6.4.8) combustible material measuring greater than
0.9 m2 (10 sq ft) or a single dimension greater
than 1.8 m (6 ft) have a flame spread rating of
50 or less. For equipment with the same
dimensions for other applications, an external
surface that is not a fire enclosure requires a
min. flammability classification of V-1.

Annex DVA Equipment with lasers meets the U.S. Code of No lasers. N/A
(10.3.1) Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act,
REDR C1370).
Annex DVA Equipment that produces ionizing radiation No ionizing radiation. N/A
(10.5.1) complies with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
Page 7 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex DVA Equipment for use on a.c. mains supply systems Single phase. N/A
(F.3.3.3) with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
Additional considerations apply for voltage
ratings that exceed the attachment cap rating or
are lower than the “Normal Operating Condition”
in Table 2 of CAN/CSA C22.2 No. 235.”

Annex DVA Equipment identified for ITE (computer) room Building-in component. N/A
(F.3.3.5) installation is marked with the rated current
Annex DVA Vertically-mounted disconnect switches and No switch used. N/A
(G.1) circuit breakers have the "on" position indicated
by the handle in the up position
Annex DVA Suitable NEC/CEC branch circuit protection Building-in component. N/A
(G.3.4) rated at the maximum circuit rating is required
for all standard supply outlets and receptacles
(such as supplied in power distribution units) if
the supply branch circuit protection is not
suitable.
Annex DVA Equipment with isolated ground (earthing) No such receptacles. N/A
(G.4.2) receptacles complies with NEC 250.146(D) and
CEC 10-112 and 10-906(8).
Annex DVA Where a fuse is used to provide Class 2 or No such fuse. N/A
(G.4.3) Class 3 current limiting, it is not operator-
accessible unless it is non- interchangeable.

Annex DVA Power distribution transformers distributing No such equipment. N/A


(G.5.3) power at 100 volts or more, and rated 10 kVA or
more, require special transformer overcurrent
protection.

Annex DVA Motor control devices are required for cord- No such equipment. N/A
(G.5.4) connected equipment with a mains-connected
motor if the equipment is rated more than 12 A,
or if the equipment has a nominal voltage rating
greater than 120 V, or if the motor is rated more
than 1/3 hp (locked rotor current over 43 A).
Annex DVA For ITE room applications, equipment with Building-in component. N/A
(Annex M) battery systems capable of supplying 750 VA for
five minutes have a battery disconnect means
that may be connected to the ITE room remote
power-off circuit.
Page 8 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex DVA Wiring terminals intended to supply Class 2 No class 2 circuit. N/A
(Q) outputs according to the NEC or CEC Part 1are
marked with the voltage rating and “Class 2” or
equivalent; marking is located adjacent to the
terminals and visible during wiring.

Annex DVB Additional requirements apply for equipment Building-in component. N/A
(1) used for entertainment purposes intended for
installation in general patient care areas of
health care facilities.

Annex DVC Additional requirements apply for equipment Building-in component. N/A
(1) intended for mounting under kitchen cabinets.
Annex DVE Some equipment, components, sub-assemblies Considered. P
(4.1.1) and materials associated with the risk of fire,
electric shock, or personal injury have
component or material ratings in accordance
with the applicable national (U.S. and Canadian)
component or material requirements.
Components required to comply include:
appliance couplers, attachment plugs, battery
back-up systems, battery packs, circuit
breakers, communication circuit accessories,
connectors (used for current interruption of non-
LPS circuits), power supply cords, direct plug-in
equipment, electrochemical capacitor modules
(energy storage modules with ultra-capacitors),
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), ground-fault current
interrupters, interconnecting cables, data
storage equipment, printed wiring, protectors for
communications circuits, receptacles, surge
protective devices, vehicle battery adapters,
wire connectors, and wire and cables.

Annex DVH Equipment for permanent connection to the Building-in component. N/A
mains supply is subjected to additional
requirements.

Annex DVH Wiring methods (terminals, leads, etc.) used for N/A
(DVH.1) the connection of the equipment to the mains
are in accordance with the NEC/CEC.
Annex DVH Terminals for permanent wiring, including N/A
(DVH.3.2) protective earthing terminals, are suitable for
U.S./Canadian wire gauge sizes, rated 125
percent of the equipment rating, and are
specially marked when specified.
Page 9 of 9 Report No. 4788327671

IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex DVH Wire binding screws are not permitted to attach N/A
(DVH.3.2) conductors larger than 10 AWG (5.3 mm 2).
Annex DVH Permanently connected equipment is required N/A
(DVH.4) to have a suitable wiring compartment and wire
bending space.

Annex DVH Equipment connected to a centralized d.c. N/A


(DVH 5.5) power system, and having one pole of the DC
mains input terminal connected to the main
protective earthing terminal in the equipment,
complies with special earthing, wiring, marking
and installation instruction requirements.
Annex DVI Equipment intended for connection to Not intended for connection to N/A
(6.7 ) telecommunication network outside plant cable telecommunication network.
is required to be protected against overvoltage
from power line crosses.

Annex DVJ Equipment connected to a telecommunication Not intended for connection to N/A
(10.6.1 ) and cable distribution networks and supplied telecommunication network.
with an earphone intended to be held against, or
in the ear is required to comply with special
acoustic pressure requirements.

---------- END OF REPORT ----------


Enclosure_1 Report No. 4788327671

Test Report issued under the responsibility of:

TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements

Report Number. .............................. : 4788327671


Date of issue................................... : 2018-04-05
Total number of pages ................... 80

Applicant’s name ........................... : Cosel Co., Ltd.


Address ........................................... : 1-6-43 Kamiakae-machi, Toyama-shi, Toyama 930-0816, Japan
Test specification:
Standard ......................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Test procedure ............................... : Informative
Non-standard test method ............ : N/A
Test Report Form No. .................... : IEC60950_1F
Test Report Form(s) Originator .... : SGS Fimko Ltd
Master TRF ..................................... : Dated 2014-02
Copyright © 2014 IEC System of Conformity Assessment Schemes for Electrotechnical
Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Enclosure_1 Page 2 of 80 Report No. 4788327671

Test item description ....................... : Switching Power Supply


Trade Mark ........................................ :

Manufacturer .................................... : Same as applicant


Model/Type reference ...................... : FETA7000T-48, FETA7000T-144, FETA7000ST-48 and
FETA7000ST-144
Ratings .............................................. : 200-240Vac 3 PHASE +PE, 50-60Hz, 22.7A (for FETA7000T-48)
200-240Vac 3 PHASE +PE, 50-60Hz, 23.9A (for FETA7000T-144)
346-415Y / 200-240VAC 3φ, 50-60Hz, 13.2A (for FETA7000ST-48)
346-415Y / 200-240VAC 3φ, 50-60Hz, 13.8A (for FETA7000ST-
144)

TRF No. IEC60950_1F


Enclosure_1 Page 3 of 80 Report No. 4788327671

Testing procedure and testing location:

CB Testing Laboratory:
Testing location/ address............................. : NATOM Corporation
6-10 Higashiohgishima, Kawasaki-ku, Kawasaki-shi,
Kanagawa, 210-0869 Japan
Associated CB Testing Laboratory:
Testing location/ address............................. :
Tested by (name + signature) ...................... : Yuji Chikazawa/
Hirokatsu Kubota
Project Handler

Approved by (name + signature) ................. : Shinichi Yokoyama/


Ikuro Kinno
Reviewer

Testing procedure: TMP/CTF Stage 1:


Testing location/ address............................. :
Tested by (name + signature) ...................... :
Approved by (name + signature) ................. :

Testing procedure: WMT/CTF Stage 2:


Testing location/ address............................. :
Tested by (name + signature) ...................... :
Witnessed by (name + signature)................ :
Approved by (name + signature) ................. :

Testing procedure:
SMT/CTF Stage 3 or 4:
Testing location/ address............................. :
Tested by (name + signature) ...................... :
Witnessed by (name + signature)................ :
Approved by (name + signature) ................. :
Supervised by (name + signature) .............. :

TRF No. IEC60950_1F


Enclosure_1 Page 4 of 80 Report No. 4788327671

List of Attachments (including a total number of pages in each attachment):


European Group Differences and National Differences. (19 pages)
Australia and New Zealand National Differences. (10 pages)
Canada National Differences. (6 pages)
U.S.A. National Differences. (5 pages)
Japan National Differences (16 pages)
Enclosure (29 pages)
Summary of testing:
Unless otherwise indicated, all tests were conducted at NATOM Corporation, 6-10 Higashiohgishima,
Kawasaki-ku, Kawasaki-shi, Kanagawa, 210-0869 Japan
Tests performed (name of test and test Testing location:
clause): --
Input Test (1.6.2)
Durability of Marking Test (1.7.11)
Energy Hazard Measurements (2.1.1.5)
Capacitance Discharge Test (2.1.1.7)
SELV Reliability Test (2.2)
Protective Bonding Test (2.6.3.4)
Humidity Test (2.9.2)
Working Voltage Measurement (2.10.2)
Distance through insulation measurements(2.10.5)
Heating Test (4.5.1)
Ball Pressure Test (4.5.5)
Touch Current Measurement (5.1)
Electric Strength Test (5.2)
Abnormal Operation Test (5.3.1 – 5.3.9)

TRF No. IEC60950_1F


Enclosure_1 Page 5 of 80 Report No. 4788327671

Summary of compliance with National Differences:


List of countries addressed
Summary of compliance with National Differences (for explanation of codes see below):
Group differences and
AT, AU, CA, DE, DK, GB, IT, JP, MY, NZ, SE, SG, TR and US.
AT= Austria, AU= Australia, CA= Canada, DE= Germany, DK= Denmark, GB= United Kingdom, IT= Italy,
JP= Japan, MY= Malaysia, NZ= New Zealand, SE= Sweden, SG = Singapore, TR= Turkey and US=
United States of America.
Group Differences of CENELEC according to the above-mentioned standard and Group Differences are
applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway,
Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
No National Differences of Malaysia and Singapore according to CB Bulletin
For National Difference see end of this report.
Additionally evaluated Test specifications (see appended test report).
EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 + A2:2013.
UL 60950-1 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL
REQUIREMENTS - Edition 2 - Revision Date 2014/10/14.
CSA C22.2 NO. 60950-1-07 + AMD 1 AMD 2 INFORMATION TECHNOLOGY EQUIPMENT –
SAFETY. PT. 1, GENERAL REQUIREMENTS - Edition 2 - Revision Date 2014/10/14
The product fulfils the requirements of IEC 60950-1: 2005 (2nd Edition)+ Am 1:2009+ Am 2:2013

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.

TRF No. IEC60950_1F


Enclosure_1 Page 6 of 80 Report No. 4788327671

Test item particulars...................................................:


Equipment mobility.................................................: [] movable [] hand-held [] transportable
[] stationary [X] for building-in [] direct plug-in
Connection to the mains........................................: [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition................................................: [X] continuous
[] rated operating / resting time:
Access location ......................................................: [] operator accessible
[] restricted access location
N/A (unit intended for building-in)
Over voltage category (OVC) ................................: [] OVC I [X] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains
supply values .........................................................: ±10%
Tested for IT power systems .................................: [] Yes [X] No
IT testing, phase-phase voltage (V) ......................: N/A
Class of equipment ................................................: [X] Class I [] Class II [] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A) .......................: 50A
Pollution degree (PD) .............................................: [] PD 1 [X] PD 2 [] PD 3
IP protection class ..................................................: IP X0
Altitude during operation (m) ................................: up to 3000 m
Altitude of test laboratory (m) ...............................: less than 2000 m
Mass of equipment (kg) .........................................: Approximately 11 kg

Possible test case verdicts:


- test case does not apply to the test object ........... : N/A
- test object does meet the requirement.................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ........................................ : 2016-10-24, 2016-11-25, 2017-12-21
Date (s) of performance of tests ............................... : 2016-10-24, 2016-12-06 to 2017-01-13, 2018-01-16
to 2018-02-19, 2018-03-29

TRF No. IEC60950_1F


Enclosure_1 Page 7 of 80 Report No. 4788327671

General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:


The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :

When differences exist; they shall be identified in the General product information section.

TRF No. IEC60950_1F


Enclosure_1 Page 8 of 80 Report No. 4788327671

Name and address of factory (ies) .......................... : 1. Cosel Co., Ltd.


1-6-43 Kamiakae-machi Toyama-shi, Toyama
930-0816, Japan
2. Cosel Co., Ltd. Tateyama Factory
78 Dogenji, Tateyama Machi Nakaniikawa-gun,
Toyama 930-0241, Japan
3. Eikoku Co., Ltd.
45-6 Nishida Kaneoke, Kokufu-cho Takayama-
shi, Gifu 509-4123, Japan
4. Eikoku Co., Ltd. Toyama Satellite Factor
223 Nakajinzu Yatsuo-Machi, Toyama-shi,
Toyama 939-2311, Japan
5. Daiyon Corp.
1-18 Zoushima, Fuchu-machi, Toyama-shi,
Toyama-Ken 939-2726, Japan
6. Kyousei Co., Ltd.
501-1 Nakaookubo Toyama-shi, Toyama-Ken
939-2243, Japan
7. Takanami Co., Ltd.
2000-39 Hirokami Imizu-shi, Toyama-Ken 939-
0256, Japan
8. Sunrise Industries Co., Ltd.
2-24-6 Terajima, Itoigawa-shi, Niigata 941-
0066, Japan
9. Wuxi Cosel Electronics Co., Ltd.
5TH FL, BLD A3, No.866 Liyuan Development
Zone Wuxi Jiangsu 214072 China
10. Glanzhokuriku Co., Ltd.
476 Hashizume machi Hakusan City 924-0812
Japan
11. Futaba Dies Co., Ltd.
762-1 Kunugiyama Nyuzen-machi Shimo
Niikawa-Gun Toyama-Ken 936-0627 Japan

Note: The test samples submitted for evaluation


are representative of the products from each factory
listed above.
General product information:

Product Description

The product is a Building-in component type Switching Power Supply.

Model FETA7000T series are intended to be used in end-product which connected to three phase star
system and delta system.

Model FETA7000ST series are intended to be used in end-product which connected to three phase, four
wire, (3/N/PE) system.

This Switching Power Supply unit has three units of CB certified component Power Supply Units (PS1,
PS2 and PS3).

TRF No. IEC60950_1F


Enclosure_1 Page 9 of 80 Report No. 4788327671

Output ratings:
Model FETA7000T-48 and FETA7000ST-48: 48Vdc (21.6-52.8Vdc), 148.2A, maximum 7113W
Model FETA7000T-144 and FETA7000ST-144: 144Vdc (64.8-158.4Vdc), 52.0A, maximum 7488W
Adjustment of output voltage range was made via component VR31.
AUX output (CN1, CN2 pin1, 2): 12 Vdc, 0.15 A
Condition of output derating: Depends on model, input voltage and ambient temperature. See Enclosure
Id. 4-01 and 4-02 for details.

Model Differences

All models are identical to each other except for output terminal connection of switching power supplies
(PS1, PS2, PS3), output rating and the following AC power distribution systems.

- FETA7000T-48 and FETA7000T-144: Three-phase, three wire, delta system and star system power
supply connection.
- FETA7000ST-48 and FETA7000ST-144: Three-phase, four wire, (3/N/PE) system power supply
connection.

Technical Considerations

- The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted
by the manufacturer’s specification of: 60 °C (See Enclosure Id. 4-01 and 4-02 for details of output
derating upon the factors including ambient temperature.)

- The product is intended for use on the following power systems: TN

- The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 + A2:2013 (which includes all European national differences, including those
specified in this test report).

- The power supply in this equipment was: Investigated to IEC 60950-1. As part of the investigation of
this product, the power supply and its test report were reviewed and found to comply with IEC 60950-
1.

- Models FETA7000T-48 and FETA7000ST-48 were tested with output voltage range of 21.6 – 52.8Vdc
(maximum 7113W), Models FETA7000T-144 and FETA7000ST-144 were tested with output voltage
range of 64.8 – 158.4Vdc (maximum 7488W), Adjustment was made via component VR31.

Engineering Conditions of Acceptability

- The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-
Ground: 428 Vrms, 976Vpk, Primary-Secondary: 349 Vrms, 1050 Vpk

- The following secondary output circuit are SELV: 48Vdc output of Models FETA7000T-48 and
FETA7000ST-48, and interface circuit (CN1, CN2) of all models.

- The following secondary output circuits are at hazardous energy levels: Outputs of all models (except
for AUX output)

- The following secondary output circuits are limited power source: AUX output

- The maximum investigated branch circuit rating is 50A

- The power supply terminals and/or connectors are: Suitable for factory wiring only

TRF No. IEC60950_1F


Enclosure_1 Page 10 of 80 Report No. 4788327671

- Proper bonding to the end-product main protective earthing termination is: Required (Chassis or
Cover)

- An investigation of the protective bonding terminals has: Not been conducted

- The following end-product enclosures are required: Electrical, Fire.

- Mains Supply Source is assumed to both Delta system and Star system during the tests for model
FETA7000T-48 and FETA7000T-144.

- Mains Supply Source is assumed to Star system during the tests for model FETA7000ST-48 and
FETA7000ST-144.

Additional Information

This report is a reissue of CB report No. 4787682858, CB test certificate No. US-29277-UL.
Base on the previously conducted testing and the review of product technical documentation including
photos, Schematics, wiring diagrams and similar, has been determined that the product continues to
comply with the standard with the following modifications.

[1] Addition of models FETA7000ST-48 and FETA7000ST-144


The compliance of models FETA7000ST-48 and FETA7000ST-144, models similar to models
FETA7000T-48 and FETA7000T-144, to IEC 60950-1 was confirmed by additionally testing and
evaluating only the differences.
[2] Replacement of Copy of marking plate of models FETA7000T-48 and FETA7000T-144.
[3] Addition of Name and address of ten factories;
- Cosel Co., Ltd. 1-6-43 Kamiakae-machi Toyama-shi, Toyama 930-0816, Japan
- Eikoku Co., Ltd. 45-6 Nishida Kaneoke, Kokufu-cho Takayama-shi, Gifu 509-4123, Japan
- Eikoku Co., Ltd. Toyama Satellite Factory, 223 Nakajinzu Yatsuo-machi, Toyama-shi, Toyama 939-
2311, Japan
- Daiyon Corp. 1-18 Zoushima, Fuchu-machi, Toyama-shi, Toyama-Ken 939-2726, Japan
- Kyousei Co., Ltd. 501-1 Nakaookubo Toyama-shi, Toyama-Ken 939-2243, Japan
- Takanami Co., Ltd. 2000-39 Hirokami Imizu-shi, Toyama-Ken 939-0256, Japan
- Sunrise Industries Co., Ltd. 2-24-6 Terajima, Itoigawa-shi, Niigata 941-0066, Japan
- Wuxi Cosel Electronics Co., Ltd. 5th Fl, Bld A3, No.866 Liyuan Development Zone Wuxi, 214072
Jiangsu, China
- Glanzhokuriku Co., Ltd. 476 Hashizume machi Hakusan City 924-0812 Japan
- Futaba Dies Co., Ltd. 762-1 Kunugiyama Nyuzen-machi Shimo Niikawa-Gun Toyama-Ken 936-0627
Japan
[4] Correction of Name and address of factories;
- From: Cosel Co., Ltd. Tateyama Factory 78 Dogenji, Tateyama-machi Nakaniikawa-gun, Toyama 930-
0241, Japan
To: Cosel Co., Ltd. Tateyama Factory 78 Dogenji, Tateyama Machi Nakaniikawa-gun, Toyama 930-
0241, Japan
[5] Correction of typographical error for load condition of 158.4V output for Power Supply output short-
circuit /overload Test
- From: 52.07V, 173A, To: 157.6V, 56.8A (see TABLE 5.3, Fault condition tests for details.)
[6] Correction of typographical error for temperature measuring point for Power Supply output short- circuit
/overload Test
52.8V output, From: T301 coil of PS1: 81°C, To: T701 coil of PS1: 81°C
158.4V output, From: T301 coil of PS1: 81°C, To: T701 coil of PS1: 81°C
[7] Replacement of photograph of model FETA7000T-144 and model FETA7000T-48 of Enclosures due to
misplacement
[8] Addition of National Differences countries for Australia (AU), Germany (DE), Japan (JP), Malaysia
(MY), New Zealand (NZ), Singapore (SG) and Turkey (TR). And addition of No National Differences

TRF No. IEC60950_1F


Enclosure_1 Page 11 of 80 Report No. 4788327671

countries for singapore and Malaysia.


Based on the previously conducted testing and the review of product construction, only following tests
were deemed necessary.
- 1.6.2 Input Test
- 2.1.1.5 Energy Hazard Measurements
- 2.1.1.7 Capacitance Discharge Test
- 2.9.2 Humidity Test
- 4.5.1 Heating Test
- 5.1 Touch Current Measurement
- 5.2 Electric Strength Test

Working voltage at inside certified component power supply units and clearance and creepage distances
were additionally assessed in this report due to deviation of mains supply systems.

In this Test Report, CENELEC mark license indicating compliance to EN standard was used to verify
component compliance to IEC standard because the standards are technically equivalent.
For table 1.5.1, UL Standard has requirements that meet or exceed the relevant IEC requirements.

Abbreviations used in the report:

- normal conditions N.C. - single fault conditions S.F.C


- functional insulation FI - basic insulation BI
- double insulation DI - supplementary insulation SI
- between parts of opposite
polarity BOP - reinforced insulation RI
- Built-in component: Final compliance is to be evaluated at the end product.

Indicate used abbreviations (if any)

TRF No. IEC60950_1F


Enclosure_1 Page 12 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1 GENERAL P

1.5 Components P
1.5.1 General P
Comply with IEC 60950-1 or relevant component Components, which are found P
standard to affect safety aspects, comply
with the requirements of this
standard or comply with the
safety requirement of the
relevant component standards.
1.5.2 Evaluation and testing of components Components, which are P
certified for IEC and/or national
standards, are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
1.5.3 Thermal controls Evaluated in certified N/A
component power supply.
1.5.4 Transformers Evaluated in certified N/A
component power supply.
1.5.5 Interconnecting cables No interconnecting cables. N/A
1.5.6 Capacitors bridging insulation Type X2 capacitors are used P
between lines.
Type Y1 capacitors are used
between line and earth comply
with IEC 60384-14 (for model
FETA7000T series).
Type Y1 capacitors are used
between Neutral and FG
comply with IEC 60384-14 (for
model FETA7000ST series).
(see appended table 1.5.1)
1.5.7 Resistors bridging insulation Evaluated in certified N/A
component power supply.
1.5.7.1 Resistors bridging functional, basic or N/A
supplementary insulation
1.5.7.2 Resistors bridging double or reinforced insulation N/A
between a.c. mains and other circuits
1.5.7.3 Resistors bridging double or reinforced insulation N/A
between a.c. mains and antenna or coaxial cable
1.5.8 Components in equipment for IT power systems N/A

TRF No. IEC60950_1F


Enclosure_1 Page 13 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.5.9 Surge suppressors No surge suppressors. N/A


1.5.9.1 General N/A
1.5.9.2 Protection of VDRs N/A
1.5.9.3 Bridging of functional insulation by a VDR N/A
1.5.9.4 Bridging of basic insulation by a VDR N/A
1.5.9.5 Bridging of supplementary, double or reinforced N/A
insulation by a VDR

1.6 Power interface P


1.6.1 AC power distribution systems TN P
1.6.2 Input current (see appended table 1.6.2) P
1.6.3 Voltage limit of hand-held equipment Not hand-held equipment. N/A
1.6.4 Neutral conductor (For model FETA7000ST P
series only)
Neutral insulated from earth
like a line conductor by at least
basic insulation.
Components between Neutral
and earth are rated the same
as for line to earth.

1.7 Marking and instructions P


1.7.1 Power rating and identification markings P
1.7.1.1 Power rating marking Unit intended for building-in. N/A
No power rating marking
required. However, marked on
the label as follows.
Multiple mains supply connections.........................: No such connection. N/A
Rated voltage(s) or voltage range(s) (V) ...............: <For reference> N/A
200-240Vac 3 PHASE (for
FETA7000T-48 and
FETA7000T-144),
346-415Y/200-240VAC 3φ(for
FETA7000ST-48 and
FETA7000ST-144)
Symbol for nature of supply, for d.c. only ...............: AC supply N/A
Rated frequency or rated frequency range (Hz) ....: 50-60Hz N/A
Rated current (mA or A) ........................................: 22.7A (for FETA7000T-48), N/A
23.9A (for FETA7000T-144)
13.2A (for FETA7000ST-48)
13.8A (for FETA7000ST-144)

TRF No. IEC60950_1F


Enclosure_1 Page 14 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.7.1.2 Identification markings P


Manufacturer’s name or trade-mark or identification Trade-mark marked on P
mark .......................................................................: Nameplate.
Model identification or type reference ...................: FETA7000T-48, P
FETA7000T-144,
FETA7000ST-48,
FETA7000ST-144
Symbol for Class II equipment only .......................: N/A
Other markings and symbols .................................: N/A
1.7.1.3 Use of graphical symbols N/A
1.7.2 Safety instructions and marking N/A
1.7.2.1 General Built-in component. N/A
1.7.2.2 Disconnect devices Built-in component. N/A
1.7.2.3 Overcurrent protective device N/A
1.7.2.4 IT power distribution systems N/A
1.7.2.5 Operator access with a tool N/A
1.7.2.6 Ozone No ozone generated. N/A
1.7.3 Short duty cycles Continuous operation. N/A
1.7.4 Supply voltage adjustment ...................................: Single voltage range. N/A
Methods and means of adjustment; reference to N/A
installation instructions .........................................:
1.7.5 Power outlets on the equipment ...........................: No power outlets provided. N/A
1.7.6 Fuse identification (marking, special fusing Evaluated as part of the N/A
characteristics, cross-reference) ..............................: certified component power
supply investigation.
1.7.7 Wiring terminals P
1.7.7.1 Protective earthing and bonding terminals .............: Symbol (60417-1-IEC-5017) P
marked adjacent to FG
terminal of Terminal Block
(TB2)
1.7.7.2 Terminals for a.c. mains supply conductors Not permanently connected N/A
equipment and No ordinary
non-detachable power supply
cord.
1.7.7.3 Terminals for d.c. mains supply conductors N/A
1.7.8 Controls and indicators N/A
1.7.8.1 Identification, location and marking ........................: No safety related controls or N/A
indicators provided.
1.7.8.2 Colours ..................................................................: N/A

TRF No. IEC60950_1F


Enclosure_1 Page 15 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.7.8.3 Symbols according to IEC 60417............................: N/A


1.7.8.4 Markings using figures ..........................................: N/A
1.7.9 Isolation of multiple power sources ........................: Single supply. N/A
1.7.10 Thermostats and other regulating devices .............: No thermostats or similar N/A
regulating devices.
1.7.11 Durability Marking is durable and legible. P
Tested by water followed with
petroleum spirit.
1.7.12 Removable parts Built-in component. N/A
1.7.13 Replaceable batteries .......................................... : No batteries. N/A
Language(s) ........................................................ : 
1.7.14 Equipment for restricted access locations ............ : Built-in component. N/A

2 PROTECTION FROM HAZARDS P


2.1 Protection from electric shock and energy hazards N/A
2.1.1 Protection in operator access areas N/A
2.1.1.1 Access to energized parts Built-in component. N/A
Test by inspection ..................................................: N/A
Test with test finger (Figure 2A) ............................: N/A
Test with test pin (Figure 2B) .................................: N/A
Test with test probe (Figure 2C) ............................: N/A
2.1.1.2 Battery compartments No TNV circuits. N/A
2.1.1.3 Access to ELV wiring Built-in component. N/A
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm)
2.1.1.4 Access to hazardous voltage circuit wiring Built-in component. N/A
2.1.1.5 Energy hazards .....................................................: Built-in component. N/A
2.1.1.6 Manual controls No such controls. N/A
2.1.1.7 Discharge of capacitors in equipment Built-in component. Tested for P
reference.
Measured voltage (V); time-constant (s) ................: 0 V, after 1 sec. (FETA7000T- 
144), 0.56 V, after 1 sec.
(FETA7000ST-48)
2.1.1.8 Energy hazards – d.c. mains supply Not intended for connected to N/A
d.c. mains supply.
a) Capacitor connected to the d.c. mains supply ..: N/A

TRF No. IEC60950_1F


Enclosure_1 Page 16 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

b) Internal battery connected to the d.c. mains N/A


supply :
2.1.1.9 Audio amplifiers .....................................................: N/A
2.1.2 Protection in service access areas Built-in component. N/A
2.1.3 Protection in restricted access locations Built-in component. N/A

2.2 SELV circuits P


2.2.1 General requirements 48V output (Models P
FETA7000T-48 and
FETA7000ST-48): Secondary
circuit supplied from certified
component power supplies,
which output evaluated as
SELV.
Voltage at Interface connectors
(CN1, CN2) are maintained
SELV levels (All models) after
single fault condition.
(see appended table 2.2)
2.2.2 Voltages under normal conditions (V) .................. : Secondary circuit voltages P
except for 144V Output
(Models FETA7000T-144 and
FETA7000ST-144) are less
than 42.4 Vpk or 60 Vdc and
are classified as SELV.
2.2.3 Voltages under fault conditions (V) ...................... : Under fault conditions voltages P
never exceed 71 Vpk and 120
Vdc and do not exceed 42.4
Vpk or 60 Vdc for more than
0.2 second. (see appended
table 2.2)
2.2.4 Connection of SELV circuits to other circuits ...... : SELV not connected to N/A
primary.

2.3 TNV circuits N/A


2.3.1 Limits No TNV circuits. N/A
Type of TNV circuits .............................................. : 
2.3.2 Separation from other circuits and from accessible N/A
parts
2.3.2.1 General requirements N/A
2.3.2.2 Protection by basic insulation N/A
2.3.2.3 Protection by earthing N/A
2.3.2.4 Protection by other constructions ......................... : N/A

TRF No. IEC60950_1F


Enclosure_1 Page 17 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.3.3 Separation from hazardous voltages N/A


Insulation employed............................................... : 
2.3.4 Connection of TNV circuits to other circuits N/A
Insulation employed............................................... : 
2.3.5 Test for operating voltages generated externally N/A

2.4 Limited current circuits N/A


2.4.1 General requirements No limited current circuits. N/A
2.4.2 Limit values N/A
Frequency (Hz) .......................................................: 
Measured current (mA)...........................................: 
Measured voltage (V) .............................................: 
Measured circuit capacitance (nF or µF) ................: 
2.4.3 Connection of limited current circuits to other N/A
circuits

2.5 Limited power sources P


a) Inherently limited output AUX output supplied from P
certified component power
supplies which output
evaluated as LPS.
b) Impedance limited output N/A
c) Regulating network or IC current limiter, limits N/A
output under normal operating and single fault
condition
Use of integrated circuit (IC) current limiters N/A
d) Overcurrent protective device limited output N/A
Max. output voltage (V), max. output current (A), 
max. apparent power (VA)..................................... :
Current rating of overcurrent protective device (A) .: 

2.6 Provisions for earthing and bonding P


2.6.1 Protective earthing Built-in component. N/A
Metal chassis is reliably
connected to protective earth in
end product.
2.6.2 Functional earthing No functional earthing. N/A
Use of symbol for functional earthing ...................: N/A

TRF No. IEC60950_1F


Enclosure_1 Page 18 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.6.3 Protective earthing and protective bonding N/A


conductors
2.6.3.1 General N/A
2.6.3.2 Size of protective earthing conductors Power supply cord is not N/A
provided.
Rated current (A), cross-sectional area (mm2), 
AWG ...................................................................... :
2.6.3.3 Size of protective bonding conductors Tested per cl. 2.6.3.4. N/A
2
Rated current (A), cross-sectional area (mm ), 
AWG ...................................................................... :
Protective current rating (A), cross-sectional area
(mm2), AWG .......................................................... :
2.6.3.4 Resistance of earthing conductors and their <Reference only> N/A
terminations; resistance (), voltage drop (V), test Voltage drop of following
current (A), duration (min) ..................................... : conductive parts are
measured, test current: 100 A
and Time duration 4 minutes.
FG terminal of Terminal Block
(TB2) to Cover: 0.301 V
2.6.3.5 Colour of insulation ................................................ : Power supply cord is not N/A
provided.
2.6.4 Terminals Built-in component. N/A
2.6.4.1 General N/A
2.6.4.2 Protective earthing and bonding terminals N/A
Rated current (A), type, nominal thread diameter 
(mm) ...................................................................... :
2.6.4.3 Separation of the protective earthing conductor N/A
from protective bonding conductors
2.6.5 Integrity of protective earthing P
2.6.5.1 Interconnection of equipment No interconnection. N/A
2.6.5.2 Components in protective earthing conductors and No such components. N/A
protective bonding conductors
2.6.5.3 Disconnection of protective earth N/A
2.6.5.4 Parts that can be removed by an operator N/A
2.6.5.5 Parts removed during servicing N/A
2.6.5.6 Corrosion resistance (see Annex J) N/A
2.6.5.7 Screws for protective bonding P
2.6.5.8 Reliance on telecommunication network or cable No TNV circuits. N/A
distribution system

TRF No. IEC60950_1F


Enclosure_1 Page 19 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.7 Overcurrent and earth fault protection in primary circuits P


2.7.1 Basic requirements This unit was evaluated as P
component protecting by the
50A circuit breaker of building
installation. Supplementary
protective devices are
integrated in the unit. Current
fuse (F101, F102) provided in
each certified component
power supply.
Instructions when protection relies on building Built-in component. N/A
installation
2.7.2 Faults not simulated in 5.3.7 Considered. P
2.7.3 Short-circuit backup protection Built-in component. N/A
2.7.4 Number and location of protective devices .......... : Evaluated as part of the N/A
certified component power
supply investigation.
2.7.5 Protection by several devices Evaluated as part of the N/A
certified component power
supply investigation.
2.7.6 Warning to service personnel ................................ : Evaluated as part of the N/A
certified component power
supply investigation.

2.8 Safety interlocks N/A


2.8.1 General principles No safety interlocks. N/A
2.8.2 Protection requirements N/A
2.8.3 Inadvertent reactivation N/A
2.8.4 Fail-safe operation N/A
Protection against extreme hazard N/A
2.8.5 Moving parts N/A
2.8.6 Overriding N/A
2.8.7 Switches, relays and their related circuits N/A
2.8.7.1 Separation distances for contact gaps and their N/A
related circuits (mm) .............................................. :
2.8.7.2 Overload test N/A
2.8.7.3 Endurance test N/A
2.8.7.4 Electric strength test N/A
2.8.8 Mechanical actuators N/A

TRF No. IEC60950_1F


Enclosure_1 Page 20 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.9 Electrical insulation P


2.9.1 Properties of insulating materials Natural rubber, asbestos or P
hygroscopic materials are not
used.
2.9.2 Humidity conditioning Humidity treatment conducted P
for 48 h.
Relative humidity (%), temperature (°C) ............... : 93%, 25°C 
2.9.3 Grade of insulation Kind of insulation and working P
voltage considered.
2.9.4 Separation from hazardous voltages P
Method(s) used ..................................................... : Method 1: double insulation or 
reinforced insulation.

2.10 Clearances, creepage distances and distances through insulation P


2.10.1 General P
2.10.1.1 Frequency ..............................................................: Considered. P
2.10.1.2 Pollution degrees ...................................................: Pollution degree 2 P
2.10.1.3 Reduced values for functional insulation Considered. See cl. 5.3.4. P
2.10.1.4 Intervening unconnected conductive parts Considered. P
2.10.1.5 Insulation with varying dimensions Single working voltage (highest N/A
value) considered.
2.10.1.6 Special separation requirements N/A
2.10.1.7 Insulation in circuits generating starting pulses No circuits generating starting N/A
pulses.
2.10.2 Determination of working voltage P
2.10.2.1 General The r.m.s. and the peak P
voltages were measured on all
cases of connections at both
delta and star system.
2.10.2.2 RMS working voltage (see appended table 2.10.2) P
2.10.2.3 Peak working voltage (see appended table 2.10.2) P
2.10.3 Clearances P
2.10.3.1 General Comply with 2.10.3.1 and P
2.10.3.2, Annex G not applied.
2.10.3.2 Mains transient voltages P
a) AC mains supply ...............................................: AC mains supply voltage: up to P
300 V, Overvoltage caterory II,
Mains transient voltage 2500
V.

TRF No. IEC60950_1F


Enclosure_1 Page 21 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

b) Earthed d.c. mains supplies ..............................: N/A


c) Unearthed d.c. mains supplies ..........................: N/A
d) Battery operation ...............................................: N/A
2.10.3.3 Clearances in primary circuits (see appended table 2.10.3 P
and 2.10.4)
2.10.3.4 Clearances in secondary circuits (see appended table 2.10.3 P
and 2.10.4)
2.10.3.5 Clearances in circuits having starting pulses No circuits generating starting N/A
pulses.
2.10.3.6 Transients from a.c. mains supply .........................: See cl. 2.10.3.9. N/A
2.10.3.7 Transients from d.c. mains supply .........................: N/A
2.10.3.8 Transients from telecommunication networks and No TNV circuits and not N/A
cable distribution systems .....................................: intended for connection to
cable distribution systems.
2.10.3.9 Measurement of transient voltage levels Not measured, same level than N/A
the mains transient voltage
considered.
a) Transients from a mains supply N/A
For an a.c. mains supply .......................................: N/A
For a d.c. mains supply .........................................: N/A
b) Transients from a telecommunication network : N/A
2.10.4 Creepage distances P
2.10.4.1 General P
2.10.4.2 Material group and comparative tracking index P
CTI tests .................................................................: Material group IIIb assumed to 
be used.
2.10.4.3 Minimum creepage distances (see appended table 2.10.3 P
and 2.10.4)
2.10.5 Solid insulation P
2.10.5.1 General P
2.10.5.2 Distances through insulation (see appended table 2.10.5) P
2.10.5.3 Insulating compound as solid insulation No such insulating part. N/A
2.10.5.4 Semiconductor devices Evaluated as part of the N/A
certified component power
supply investigation.
2.10.5.5. Cemented joints No such insulating part. N/A
2.10.5.6 Thin sheet material – General N/A
2.10.5.7 Separable thin sheet material N/A
Number of layers (pcs) ...........................................: 

TRF No. IEC60950_1F


Enclosure_1 Page 22 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.10.5.8 Non-separable thin sheet material N/A


2.10.5.9 Thin sheet material – standard test procedure N/A
Electric strength test 
2.10.5.10 Thin sheet material – alternative test procedure N/A
Electric strength test 
2.10.5.11 Insulation in wound components P
2.10.5.12 Wire in wound components Evaluated as part of the N/A
certified component power
supply investigation.
Working voltage .....................................................: N/A
a) Basic insulation not under stress ......................: N/A
b) Basic, supplementary, reinforced insulation ......: N/A
c) Compliance with Annex U .................................: N/A
Two wires in contact inside wound component; N/A
angle between 45 and 90 ...................................:
2.10.5.13 Wire with solvent-based enamel in wound Not used. N/A
components
Electric strength test 
Routine test N/A
2.10.5.14 Additional insulation in wound components Evaluated as part of the N/A
certified component power
supply investigation.
Working voltage .....................................................: N/A
- Basic insulation not under stress ........................: N/A
- Supplementary, reinforced insulation ..................: N/A
2.10.6 Construction of printed boards P
2.10.6.1 Uncoated printed boards (see appended table 2.10.3 P
and 2.10.4)
2.10.6.2 Coated printed boards Coating not used for insulation. N/A
2.10.6.3 Insulation between conductors on the same inner N/A
surface of a printed board
2.10.6.4 Insulation between conductors on different layers of N/A
a printed board
Distance through insulation N/A
Number of insulation layers (pcs) ...........................: N/A
2.10.7 Component external terminations N/A
2.10.8 Tests on coated printed boards and coated Coating not used for insulation. N/A
components

TRF No. IEC60950_1F


Enclosure_1 Page 23 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.10.8.1 Sample preparation and preliminary inspection N/A


2.10.8.2 Thermal conditioning N/A
2.10.8.3 Electric strength test N/A
2.10.8.4 Abrasion resistance test N/A
2.10.9 Thermal cycling N/A
2.10.10 Test for Pollution Degree 1 environment and N/A
insulating compound
2.10.11 Tests for semiconductor devices and cemented N/A
joints
2.10.12 Enclosed and sealed parts N/A

3 WIRING, CONNECTIONS AND SUPPLY P


3.1 General P
3.1.1 Current rating and overcurrent protection Sufficient cross sectional area P
of internal wiring. Internal wires
are UL recognized wires.
3.1.2 Protection against mechanical damage Internal wirings are well routed P
and free from sharp edges.
3.1.3 Securing of internal wiring Internal secondary wires with P
basic isolation are routed so
that they are not close to any
live bare components.
Wires are adequately fixed to
prevent excessive strain or
damage of the conductors’
insulation.
3.1.4 Insulation of conductors The insulation of the individual P
conductors is suitable for the
application and the working
voltage. (see appended table
1.5.1 and 2.10.5)
3.1.5 Beads and ceramic insulators Not used. N/A
3.1.6 Screws for electrical contact pressure Relevant electrical and P
earthing connections engage at
least two complete threads into
metal.
No screws of insulating
material are used for electrical
and earthing connections.
3.1.7 Insulating materials in electrical connections Relevant current carrying N/A
connections are metal to metal.
3.1.8 Self-tapping and spaced thread screws No such screws. N/A

TRF No. IEC60950_1F


Enclosure_1 Page 24 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

3.1.9 Termination of conductors Conductors are suitable P


terminated, creepage and
clearances maintained, second
secureing for soldered
terminations provided.
10 N pull test 10N applied to relevant P
conductors.
3.1.10 Sleeving on wiring Sleeving used as P
supplementary insulation on
internal wiring is retained by
heat shrinkable tube.

3.2 Connection to a mains supply N/A


3.2.1 Means of connection Built-in component. N/A
3.2.1.1 Connection to an a.c. mains supply N/A
3.2.1.2 Connection to a d.c. mains supply N/A
3.2.2 Multiple supply connections N/A
3.2.3 Permanently connected equipment N/A
Number of conductors, diameter of cable and 
conduits (mm) ....................................................... :
3.2.4 Appliance inlets N/A
3.2.5 Power supply cords N/A
3.2.5.1 AC power supply cords N/A
Type ...................................................................... : 
2
Rated current (A), cross-sectional area (mm ), 
AWG ..................................................................... :
3.2.5.2 DC power supply cords N/A
3.2.6 Cord anchorages and strain relief N/A
Mass of equipment (kg), pull (N) ......................... : 
Longitudinal displacement (mm) ........................... : 
3.2.7 Protection against mechanical damage N/A
3.2.8 Cord guards N/A
Diameter or minor dimension D (mm); test mass (g) 
............................................................................... :
Radius of curvature of cord (mm) .......................... : 
3.2.9 Supply wiring space N/A

3.3 Wiring terminals for connection of external conductors N/A


3.3.1 Wiring terminals Built-in component. N/A

TRF No. IEC60950_1F


Enclosure_1 Page 25 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

3.3.2 Connection of non-detachable power supply cords N/A


3.3.3 Screw terminals N/A
3.3.4 Conductor sizes to be connected N/A
Rated current (A), cord/cable type, cross-sectional 
area (mm2) ............................................................. :
3.3.5 Wiring terminal sizes N/A
Rated current (A), type, nominal thread diameter 
(mm) ...................................................................... :
3.3.6 Wiring terminal design N/A
3.3.7 Grouping of wiring terminals N/A
3.3.8 Stranded wire N/A

3.4 Disconnection from the mains supply N/A


3.4.1 General requirement Built-in component. N/A
3.4.2 Disconnect devices N/A
3.4.3 Permanently connected equipment N/A
3.4.4 Parts which remain energized N/A
3.4.5 Switches in flexible cords N/A
3.4.6 Number of poles - single-phase and d.c. equipment N/A
3.4.7 Number of poles - three-phase equipment N/A
3.4.8 Switches as disconnect devices N/A
3.4.9 Plugs as disconnect devices N/A
3.4.10 Interconnected equipment N/A
3.4.11 Multiple power sources N/A

3.5 Interconnection of equipment N/A


3.5.1 General requirements Built-in component. N/A
3.5.2 Types of interconnection circuits ...........................: N/A
3.5.3 ELV circuits as interconnection circuits N/A
3.5.4 Data ports for additional equipment N/A

4 PHYSICAL REQUIREMENTS P
4.1 Stability N/A
Angle of 10 Built-in component. N/A
Test force (N) .........................................................: N/A

TRF No. IEC60950_1F


Enclosure_1 Page 26 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

4.2 Mechanical strength N/A


4.2.1 General Built-in component. N/A
Rack-mounted equipment. N/A
4.2.2 Steady force test, 10 N N/A
4.2.3 Steady force test, 30 N N/A
4.2.4 Steady force test, 250 N N/A
4.2.5 Impact test N/A
Fall test N/A
Swing test N/A
4.2.6 Drop test; height (mm) ...........................................: N/A
4.2.7 Stress relief test N/A
4.2.8 Cathode ray tubes N/A
Picture tube separately certified ............................: N/A
4.2.9 High pressure lamps N/A
4.2.10 Wall or ceiling mounted equipment; force (N) .......: N/A

4.3 Design and construction P


4.3.1 Edges and corners Built-in component. N/A
Note) Edges and corners are
sufficient rounded and smooth.
4.3.2 Handles and manual controls; force (N) ............. : No such parts. N/A
4.3.3 Adjustable controls No such controls. N/A
4.3.4 Securing of parts Electrical and mechanical P
connections can be expected to
withstand usual mechanical
stress.
Relevant screws are provided
with means of locking.
4.3.5 Connection by plugs and sockets N/A
4.3.6 Direct plug-in equipment Not direct plug-in equipment. N/A
Torque ..................................................................: 
Compliance with the relevant mains plug standard N/A
...............................................................................:
4.3.7 Heating elements in earthed equipment No heating elements. N/A
4.3.8 Batteries No batteries. N/A
- Overcharging of a rechargeable battery N/A

TRF No. IEC60950_1F


Enclosure_1 Page 27 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

- Unintentional charging of a non-rechargeable N/A


battery
- Reverse charging of a rechargeable battery N/A
- Excessive discharging rate for any battery N/A
4.3.9 Oil and grease N/A
4.3.10 Dust, powders, liquids and gases N/A
4.3.11 Containers for liquids or gases N/A
4.3.12 Flammable liquids .................................................: N/A
Quantity of liquid (l) ...............................................: N/A
Flash point (C) .....................................................: N/A
4.3.13 Radiation No radiation hazards. N/A
4.3.13.1 General N/A
4.3.13.2 Ionizing radiation No ionising radiation. N/A
Measured radiation (pA/kg) ..................................: 
Measured high-voltage (kV) .................................: 
Measured focus voltage (kV) ................................: 
CRT markings .......................................................: 
4.3.13.3 Effect of ultraviolet (UV) radiation on materials No ultraviolet (UV) radiation. N/A
Part, property, retention after test, flammability N/A
classification .........................................................:
4.3.13.4 Human exposure to ultraviolet (UV) radiation ......: N/A
4.3.13.5 Lasers (including laser diodes) and LEDs N/A
4.3.13.5.1 Lasers (including laser diodes) No laser. N/A
Laser class ............................................................: 
4.3.13.5.2 Light emitting diodes (LEDs) LED is used for only indicator. N/A
4.3.13.6 Other types ...........................................................: N/A

4.4 Protection against hazardous moving parts N/A


4.4.1 General No hazardous moving parts. N/A
4.4.2 Protection in operator access areas .................... : N/A
Household and home/office document/media N/A
shredders
4.4.3 Protection in restricted access locations ............. : N/A
4.4.4 Protection in service access areas N/A
4.4.5 Protection against moving fan blades N/A
4.4.5.1 General N/A

TRF No. IEC60950_1F


Enclosure_1 Page 28 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Not considered to cause pain or injury. a)…………: N/A


Is considered to cause pain, not injury. b) ………...: N/A
Considered to cause injury. c) …………: N/A
4.4.5.2 Protection for users N/A
Use of symbol or warning …………………………..: N/A
4.4.5.3 Protection for service persons N/A
Use of symbol or warning …………………………..: N/A

4.5 Thermal requirements P


4.5.1 General P
4.5.2 Temperature tests (see appended table 4.5) P
Normal load condition per Annex L ..................... : L7 
4.5.3 Temperature limits for materials (see appended table 4.5) P
4.5.4 Touch temperature limits Built-in component. N/A
4.5.5 Resistance to abnormal heat ............................... : (see appended table 4.5.5.) P
and Evaluated as part of the
certified component power
supply investigation.

4.6 Openings in enclosures N/A


4.6.1 Top and side openings Built-in component. N/A
Dimensions (mm) ................................................ : 
4.6.2 Bottoms of fire enclosures N/A
Construction of the bottomm, dimensions (mm) .. : 
4.6.3 Doors or covers in fire enclosures N/A
4.6.4 Openings in transportable equipment N/A
4.6.4.1 Constructional design measures N/A
Dimensions (mm) ................................................ : 
4.6.4.2 Evaluation measures for larger openings N/A
4.6.4.3 Use of metallized parts N/A
4.6.5 Adhesives for constructional purposes N/A
Conditioning temperature (C), time (weeks) ....... : 

4.7 Resistance to fire P

TRF No. IEC60950_1F


Enclosure_1 Page 29 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

4.7.1 Reducing the risk of ignition and spread of flame Materials with the required P
flammability classes are used.
Safety relevant components
used within their specified
rating.
Electrical parts are not likely to
ignite nearby materials.
Temperatures see 4.5.2.
Method 1, selection and application of components (see appended table 4.7) P
wiring and materials
Method 2, application of all of simulated fault N/A
condition tests
4.7.2 Conditions for a fire enclosure Built-in component: fire N/A
enclosure is to be provided by
the end product.
4.7.2.1 Parts requiring a fire enclosure N/A
4.7.2.2 Parts not requiring a fire enclosure N/A
4.7.3 Materials P
4.7.3.1 General Materials with the required P
flammability classes are used.
4.7.3.2 Materials for fire enclosures N/A
4.7.3.3 Materials for components and other parts outside N/A
fire enclosures
4.7.3.4 Materials for components and other parts inside fire Internal components except P
enclosures small parts are V-2, HF-2 or
better. Small parts were
mounted on minimum V-1 PWB.
4.7.3.5 Materials for air filter assemblies No air filter assemblies. N/A
4.7.3.6 Materials used in high-voltage components No high voltage (>4 kV) N/A
components.

5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P


5.1 Touch current and protective conductor current P
5.1.1 General (according Annex D) P
Built-in component.
Tested for TN system.
5.1.2 Configuration of equipment under test (EUT) Single supply, independently P
tested.
5.1.2.1 Single connection to an a.c. mains supply Single supply, independently P
tested.
5.1.2.2 Redundant multiple connections to an a.c. mains N/A
supply

TRF No. IEC60950_1F


Enclosure_1 Page 30 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

5.1.2.3 Simultaneous multiple connections to an a.c. mains N/A


supply
5.1.3 Test circuit Per figure 5A. P
5.1.4 Application of measuring instrument Per Annex D. P
5.1.5 Test procedure P
5.1.6 Test measurements P
Supply voltage (V) ................................................ : (see appended table 5.1) 
Measured touch current (mA) ............................... : (see appended table 5.1) 
Max. allowed touch current (mA) .......................... : (see appended table 5.1) 
Measured protective conductor current (mA) ....... : 
Max. allowed protective conductor current (mA) ... : 
5.1.7 Equipment with touch current exceeding 3,5 mA Touch current does not exceed N/A
3.5 mA.
5.1.7.1 General ................................................................. : N/A
5.1.7.2 Simultaneous multiple connections to the supply N/A
5.1.8 Touch currents to telecommunication networks and N/A
cable distribution systems and from
telecommunication networks
5.1.8.1 Limitation of the touch current to a Not connected to N/A
telecommunication network or to a cable telecommunication networks
distribution system and cable distribution systems.
Supply voltage (V) ................................................ : 
Measured touch current (mA) ............................... : 
Max. allowed touch current (mA) .......................... : 
5.1.8.2 Summation of touch currents from N/A
telecommunication networks
a) EUT with earthed telecommunication ports ..... : N/A
b) EUT whose telecommunication ports have no N/A
reference to protective earth

5.2 Electric strength P


5.2.1 General (see appended table 5.2) P
5.2.2 Test procedure No insulation breakdown P
detected during the test.

5.3 Abnormal operating and fault conditions P


5.3.1 Protection against overload and abnormal (see appended table 5.3) P
operation

TRF No. IEC60950_1F


Enclosure_1 Page 31 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

5.3.2 Motors Evaluated in certified N/A


component power supply.
5.3.3 Transformers Evaluated in certified N/A
component power supply.
5.3.4 Functional insulation .............................................. : Functional insulation between P
the phases before the fuse
complies with method a).
Other, Method c).
5.3.5 Electromechanical components Not provided. N/A
5.3.6 Audio amplifiers in ITE .......................................... : No audio amplifier. N/A
5.3.7 Simulation of faults (see appended table 5.3) P
5.3.8 Unattended equipment No such equipment. N/A
5.3.9 Compliance criteria for abnormal operating and P
fault conditions
5.3.9.1 During the tests No fire propagated beyond the P
equipment.
No molten metal was emitted.
(see appended table 5.3)
5.3.9.2 After the tests Electric strength test primary to P
Secondary and Primary to
Ground passed.
(see appended table 5.2)

6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A


6.1 Protection of telecommunication network service persons, and users of other N/A
equipment connected to the network, from hazards in the equipment
6.1.1 Protection from hazardous voltages N/A
6.1.2 Separation of the telecommunication network from earth N/A
6.1.2.1 Requirements No TNV circuits. N/A
Supply voltage (V) ............................................... : 
Current in the test circuit (mA) ........................... : 
6.1.2.2 Exclusions ............................................................ : N/A

6.2 Protection of equipment users from overvoltages on telecommunication N/A


networks
6.2.1 Separation requirements No TNV circuits. N/A
6.2.2 Electric strength test procedure N/A
6.2.2.1 Impulse test N/A
6.2.2.2 Steady-state test N/A

TRF No. IEC60950_1F


Enclosure_1 Page 32 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

6.2.2.3 Compliance criteria N/A

6.3 Protection of the telecommunication wiring system from overheating N/A


Max. output current (A) ........................................ : No TNV circuits. 
Current limiting method ....................................... : 

7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A


7.1 General Not connected to cable N/A
distribution systems.
7.2 Protection of cable distribution system service N/A
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
7.3 Protection of equipment users from overvoltages N/A
on the cable distribution system
7.4 Insulation between primary circuits and cable N/A
distribution systems
7.4.1 General N/A
7.4.2 Voltage surge test N/A
7.4.3 Impulse test N/A

A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A


A.1 Flammability test for fire enclosures of movable Not tested; flammability data N/A
equipment having a total mass exceeding were taken from available
18 kg, and of stationary equipment (see 4.7.3.2) literature.
A.1.1 Samples ................................................................ : 
Wall thickness (mm) ............................................. : 
A.1.2 Conditioning of samples; temperature (C) ......... : N/A
A.1.3 Mounting of samples ............................................ : N/A
A.1.4 Test flame (see IEC 60695-11-3) N/A
Flame A, B, C or D ............................................... : 
A.1.5 Test procedure N/A
A.1.6 Compliance criteria N/A
Sample 1 burning time (s)..................................... : 
Sample 2 burning time (s)..................................... : 
Sample 3 burning time (s)..................................... : 

TRF No. IEC60950_1F


Enclosure_1 Page 33 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

A.2 Flammability test for fire enclosures of movable equipment having a total N/A
mass not exceeding 18 kg, and for material and components located inside fire
enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1 Samples, material ................................................. : 
Wall thickness (mm) ............................................. : 
A.2.2 Conditioning of samples; temperature (°C) ......... : N/A
A.2.3 Mounting of samples ............................................ : N/A
A.2.4 Test flame (see IEC 60695-11-4) N/A
Flame A, B or C ................................................... : 
A.2.5 Test procedure N/A
A.2.6 Compliance criteria N/A
Sample 1 burning time (s)..................................... : 
Sample 2 burning time (s)..................................... : 
Sample 3 burning time (s)..................................... : 
A.2.7 Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N/A
Sample 1 burning time (s)..................................... : 
Sample 2 burning time (s)..................................... : 
Sample 3 burning time (s)..................................... : 
A.3 Hot flaming oil test (see 4.6.2) N/A
A.3.1 Mounting of samples N/A
A.3.2 Test procedure N/A
A.3.3 Compliance criterion N/A

B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and N/A
5.3.2)
B.1 General requirements Evaluated in certified N/A
component power supply.
Position .................................................................: 
Manufacturer ........................................................: 
Type ......................................................................: 
Rated values ........................................................: 
B.2 Test conditions N/A
B.3 Maximum temperatures N/A
B.4 Running overload test N/A
B.5 Locked-rotor overload test N/A
Test duration (days) ..............................................: 

TRF No. IEC60950_1F


Enclosure_1 Page 34 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Electric strength test: test voltage (V) ...................: 


B.6 Running overload test for d.c. motors in N/A
secondary circuits
B.6.1 General N/A
B.6.2 Test procedure N/A
B.6.3 Alternative test procedure N/A
B.6.4 Electric strength test; test voltage (V) ...................: N/A
B.7 Locked-rotor overload test for d.c. motors in N/A
secondary circuits
B.7.1 General N/A
B.7.2 Test procedure N/A
B.7.3 Alternative test procedure N/A
B.7.4 Electric strength test; test voltage (V) .................. : N/A
B.8 Test for motors with capacitors N/A
B.9 Test for three-phase motors N/A
B.10 Test for series motors N/A
Operating voltage (V) ...........................................: 

C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) N/A


Position .................................................................: Evaluated in certified 
component power supply.
Manufacturer ........................................................: 
Type ......................................................................: 
Rated values ........................................................: 
Method of protection ............................................. : 
C.1 Overload test N/A
C.2 Insulation N/A
Protection from displacement of windings ............ : N/A

D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS P


(see 5.1.4)
D.1 Measuring instrument P
D.2 Alternative measuring instrument N/A

E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N/A

TRF No. IEC60950_1F


Enclosure_1 Page 35 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES P


(see 2.10 and Annex G)

G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM N/A


CLEARANCES
G.1 Clearances Not considered. N/A
G.1.1 General N/A
G.1.2 Summary of the procedure for determining N/A
minimum clearances
G.2 Determination of mains transient voltage (V) N/A
G.2.1 AC mains supply ...................................................: N/A
G.2.2 Earthed d.c. mains supplies .................................: N/A
G.2.3 Unearthed d.c. mains supplies .............................: N/A
G.2.4 Battery operation ..................................................: N/A
G.3 Determination of telecommunication network N/A
transient voltage (V) .......................................... :
G.4 Determination of required withstand voltage (V) N/A
G.4.1 Mains transients and internal repetitive peaks .....: N/A
G.4.2 Transients from telecommunication networks ......: N/A
G.4.3 Combination of transients N/A
G.4.4 Transients from cable distribution systems N/A
G.5 Measurement of transient voltages (V) N/A
a) Transients from a mains supply N/A
For an a.c. mains supply N/A
For a d.c. mains supply N/A
b) Transients from a telecommunication network N/A
G.6 Determination of minimum clearances ........... : N/A

H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A

J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N/A

TRF No. IEC60950_1F


Enclosure_1 Page 36 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Metal(s) used ........................................................: <Reference only> 


Chassis to FG:
Chassis (High Cr stainless) =>
Screw (Ni on copper) => Tab
(Ni on copper) => PWB trace
(copper) => softsolder =>
Terminal Block (Ti on brass)
All combination are less than
0.6 V

K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) N/A


K.1 Making and breaking capacity Evaluated in certified N/A
component power supply.
K.2 Thermostat reliability; operating voltage (V) .........: N/A
K.3 Thermostat endurance test; operating voltage (V) N/A
...............................................................................:
K.4 Temperature limiter endurance; operating voltage N/A
(V) .........................................................................:
K.5 Thermal cut-out reliability N/A
K.6 Stability of operation N/A

L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL P


BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
L.1 Typewriters N/A
L.2 Adding machines and cash registers N/A
L.3 Erasers N/A
L.4 Pencil sharpeners N/A
L.5 Duplicators and copy machines N/A
L.6 Motor-operated files N/A
L.7 Other business equipment Rated output. P

M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A


M.1 Introduction No ringing signals generated. N/A
M.2 Method A N/A
M.3 Method B N/A
M.3.1 Ringing signal N/A
M.3.1.1 Frequency (Hz) .....................................................: 
M.3.1.2 Voltage (V) ............................................................: 
M.3.1.3 Cadence; time (s), voltage (V) ..............................: 

TRF No. IEC60950_1F


Enclosure_1 Page 37 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

M.3.1.4 Single fault current (mA) .......................................: 


M.3.2 Tripping device and monitoring voltage ................: N/A
M.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage
M.3.2.2 Tripping device N/A
M.3.2.3 Monitoring voltage (V) ..........................................: N/A

N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, N/A
7.3.2, 7.4.3 and Clause G.5)
N.1 ITU-T impulse test generators Not used. N/A
N.2 IEC 60065 impulse test generator N/A

P ANNEX P, NORMATIVE REFERENCES 

Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) N/A


- Preferred climatic categories ..............................: Not used. N/A
- Maximum continuous voltage .............................: N/A
- Combination pulse current .................................: N/A
Body of the VDR N/A
Test according to IEC60695-11-5.........................:
Body of the VDR. N/A
Flammability class of material ( min V-1)..............:

R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL N/A


PROGRAMMES
R.1 Minimum separation distances for unpopulated Not applied. N/A
coated printed boards (see 2.10.6.2)
R.2 Reduced clearances (see 2.10.3) N/A

S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A


S.1 Test equipment Not applied. N/A
S.2 Test procedure N/A
S.3 Examples of waveforms during impulse testing N/A

T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER N/A


(see 1.1.2)
Not applied. 

TRF No. IEC60950_1F


Enclosure_1 Page 38 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED N/A


INSULATION (see 2.10.5.4)
Evaluated as part of the 
certified component power
supply investigation.

V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) P


V.1 Introduction Considered. P
V.2 TN power distribution systems P

W ANNEX W, SUMMATION OF TOUCH CURRENTS P


W.1 Touch current from electronic circuits Considered. P
W.1.1 Floating circuits P
W.1.2 Earthed circuits P
W.2 Interconnection of several equipments N/A
W.2.1 Isolation N/A
W.2.2 Common return, isolated from earth N/A
W.2.3 Common return, connected to protective earth N/A

X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause P


C.1)
X.1 Determination of maximum input current Considered. P
X.2 Overload test procedure P

Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A


Y.1 Test apparatus ......................................................: No ultraviolet light source. N/A
Y.2 Mounting of test samples ......................................: N/A
Y.3 Carbon-arc light-exposure apparatus ...................: N/A
Y.4 Xenon-arc light exposure apparatus ....................: N/A

Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) P

AA ANNEX AA, MANDREL TEST (see 2.10.5.8) N/A

BB ANNEX BB, CHANGES IN THE SECOND EDITION 

TRF No. IEC60950_1F


Enclosure_1 Page 39 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters N/A


CC.1 General No such device used. N/A
CC.2 Test program 1……………………………………….: N/A
CC.3 Test program 2……………………………………….: N/A
CC.4 Test program 3.....................................................: N/A
CC.5 Compliance...........................................................: N/A

DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment N/A
DD.1 General Not rack-mounted equipment. N/A
DD.2 Mechanical strength test, variable N………………..: N/A
DD.3 Mechanical strength test, 250N, including end N/A
stops……………………………………………………:
DD.4 Compliance……………………………………………. N/A
:

EE ANNEX EE, Household and home/office document/media shredders N/A


EE.1 General N/A
EE.2 Markings and instructions N/A
Use of markings or symbols…………………………: N/A
Information of user instructions, maintenance N/A
and/or servicing instructions…………………………:
EE.3 Inadvertent reactivation test…………………………: N/A
EE.4 Disconnection of power to hazardous moving parts: N/A
Use of markings or symbols…………………………: N/A
EE.5 Protection against hazardous moving parts N/A
Test with test finger (Figure 2A) ……………………: N/A
Test with wedge probe (Figure EE1 and EE2) ……: N/A

TRF No. IEC60950_1F


Enclosure_1 Page 40 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.5.1 TABLE: List of critical components P


Object/part No. Manufacturer/ Type/model Technical data Standard Mark(s) of
trademark (Edition / year) conformity1)
Terminal Blocks Osada Co., Ltd. OTB-910-BL (PRI/GND/SEC) UL 1059 UL
(TB1, TB2, TB3, 600V, 115A, (E121961)
TB4) 130 C
Base of Terminal Wintech Polymer 3316 PBT, RTI: 140 UL 94 UL
Blocks (TB1, TB2, Ltd. C, (E213445)
TB3, TB4) V-0, Minimum
0.38 mm thick.
X-Capacitors (SEMKO) Cowell PCX2 339 (Line-to-Line) IEC/EN 60384- SEMKO
(C11, C12, C13) Fashion Co., Ltd. 305 Vac, 14 (SE/0256-4J)
(for model Pilkor Electronics 0.68μF, Class UL 60384-14 UL
FETA7000T-48, (UL) Cowell X2 (E165646)
FETA7000T-144) Fashion Co., Ltd.
X-Capacitors (C11, (SEMKO) Cowell PCX2 339 (Line-to-Line) IEC/EN 60384- SEMKO
C12, C13, C14) Fashion Co., Ltd. 305 Vac, 14 (SE/0256-4J)
(for model Pilkor Electronics 0.68μF, Class UL 60384-14 UL
FETA7000ST-48, (UL) Cowell X2 (E165646)
FETA7000ST-144) Fashion Co., Ltd. Capacitor (C14)
is connected to
each Capacitors
(C11, C12 and
C13) in series.
Inductor (L11) Toho Zinc Co., FKY-160GK- (Line-to-Line) -- --
(for model Ltd. 3010HRS Core: Ferrite
FETA7000T-48, See Enclosure
FETA7000T-144) Id. 2-01 for
detail.
Core Case of Wintech Polymer CRN7000 PBT, RTI: 140 UL 94 UL
Inductor (L11) Ltd. C, (E213445)
(for model V-0, Minimum
FETA7000T-48, 0.32 mm thick.
FETA7000T-144)
Y-Capacitors Murata Mfg. Co., KX (PRI-to-GND) IEC 60384-14 VDE
(C14, C15, C16) Ltd. 250 V, 3300 pF, (40002831)
(for model Class Y1 UL 60384-14 UL (E37921)
FETA7000T-48,
FETA7000T-144)
Y-Capacitor (C15) Murata Mfg. Co., KX (Neutral-to- IEC 60384-14 VDE
(for model Ltd. GND) 250 V, (40002831)
FETA7000ST-48, 3300 pF, Class UL 60384-14 UL (E37921)
FETA7000ST-144) Y1

TRF No. IEC60950_1F


Enclosure_1 Page 41 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Switching Power Cosel Co., Ltd. FETA2500BA-48 (PRI/SEC/GND) IEC 60950-1, UL (CB)
Supplies (PS1, Input: 200- IEC 62368-1 (4788327644)
PS2, PS3) 240Vac
50-60Hz 13.8 A UL 60950-1 UL (E132067)
Output: 48Vdc
52A
Secondary Internal Interchangeable Interchangeable (SEC) Minimum UL 758 UL
Wire 80 C, Minimum
300 Vac
Insulation tube Nikkan Industries E-651U-1 Supplementary UL 224 UL (E88468)
Co., Ltd. Insulation,
Silicone rubber,
300V, 200 C
Insulation sheet Sabic Japan L L C FR700 Basic Insulation, UL 94 UL (E207780)
PC, RTI: 130
C,
V-0, 0.25 mm
thick.
Alternate AGC CARBOGLASS Basic Insulation, UL 94 UL (E141248)
Polycarbonate Co., CFR230B PC, RTI: 130
Ltd. C,
V-0, 0.25 mm
thick.
Chassis and Cover -- -- High Cr -- --
stainless
1 mm thick.
PWB Interchangeable Interchangeable V-0, minimum UL 796 UL
130 C
Supplementary information: The CBTL has verified the component information.
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.

TRF No. IEC60950_1F


Enclosure_1 Page 42 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.5.1 TABLE: Opto Electronic Devices N/A


Manufacturer ............................................... : --
Type ............................................................ : --
Separately tested ........................................ : --
Bridging insulation ....................................... : --
External creepage distance ........................ : --
Internal creepage distance .......................... : --
Distance through insulation ......................... : --
Tested under the following conditions......... : --
Input ............................................................ : --
Output.......................................................... : --
supplementary information
--

TRF No. IEC60950_1F


Enclosure_1 Page 43 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1.6.2 TABLE: Electrical data (in normal conditions) P


U (V) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status
-- Phase T, -- -- -- Phase T, --
S, R S, R
FETA7000 -- -- -- -- -- --
T-48
Power -- -- -- -- -- 3 PHASE, Star System
Source
Connection
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 50Hz, 48V, 148.2A
23.0 23.0
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 60Hz, 48V, 148.2A
23.0 23.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 50Hz, 48V, 148.2A
19.0 19.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 60Hz, 48V, 148.2A
19.0 19.0
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 50Hz, 52.8V, 134.73A
23.0 23.0
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 60Hz, 52.8V, 134.73A
23.0 23.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 50Hz, 52.8V, 134.73A
19.0 19.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 60Hz, 52.8V, 134.73A
19.0 19.0
Power -- -- -- -- -- 3 PHASE, Delta System, Gnd
Source connected to R line.
Connection
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 50Hz, 48V, 148.2A
22.5 22.5
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 60Hz, 48V, 148.2A
22.5 22.5
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 50Hz, 48V, 148.2A
19.0 19.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 60Hz, 48V, 148.2A
19.0 19.0
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 50Hz, 52.8V, 134.73A
22.5 22.5
200 22.5, 22.5, 22.7 -- (+) 22.5, 22.5, 60Hz, 52.8V, 134.73A
22.5 22.5
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 50Hz, 52.8V, 134.73A

TRF No. IEC60950_1F


Enclosure_1 Page 44 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

19.0 19.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 60Hz, 52.8V, 134.73A
19.0 19.0
FETA7000 -- -- -- -- -- --
T-144
Power -- -- -- -- -- 3 PHASE, Star System
Source
Connection
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 50 Hz, 144 V, 52 A
24.0 24.0
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 60 Hz, 144 V, 52 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 144 V, 52 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 144 V, 52 A
20.0 20.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 50 Hz, 158.4 V, 47.28 A
24.0 24.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 60 Hz, 158.4 V, 47.28 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 158.4 V, 47.28 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 158.4 V, 47.28 A
20.0 20.0
Power -- -- -- -- -- 3 PHASE, Delta System, Gnd
Source connected to R line.
Connection
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 50 Hz, 144 V, 52 A
24.0 24.0
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 60 Hz, 144 V, 52 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 144 V, 52 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 144 V, 52 A
20.0 20.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 50 Hz, 158.4 V, 47.28 A
24.0 24.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 60 Hz, 158.4 V, 47.28 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 158.4 V, 47.28 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 158.4 V, 47.28 A
20.0 20.0

TRF No. IEC60950_1F


Enclosure_1 Page 45 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

-- Phase L1, -- -- -- Phase L1, --


L2, L3 L2, L3
FETA7000 -- -- -- -- -- --
ST-48
Power -- -- -- -- -- 3 PHASE, Star (3/N/PE) System
Source
Connection
346/200 13.0, 13.0, 13.2 -- (+) 13.0, 13.0, 50Hz, 48V, 148.2A
13.0 13.0
346/200 13.0, 13.0, 13.2 -- (+) 13.0, 13.0, 60Hz, 48V, 148.2A
13.0 13.0
415/240 10.8, 10.8, 13.2 -- (+) 10.8, 10.8, 50Hz, 48V, 148.2A
10.8 10.8
415/240 10.8, 10.8, 13.2 -- (+) 10.8, 10.8, 60Hz, 48V, 148.2A
10.8 10.8
346/200 13.0, 13.0, 13.2 -- (+) 13.0, 13.0, 50Hz, 52.8V, 134.73A
13.0 13.0
346/200 13.0, 13.0, 13.2 -- (+) 13.0, 13.0, 60Hz, 52.8V, 134.73A
13.0 13.0
415/240 10.8, 10.8, 13.2 -- (+) 10.8, 10.8, 50Hz, 52.8V, 134.73A
10.8 10.8
415/240 10.8, 10.8, 13.2 -- (+) 10.8, 10.8, 60Hz, 52.8V, 134.73A
10.8 10.8
FETA7000 -- -- -- -- -- --
ST-144
Power -- -- -- -- -- 3 PHASE, Star (3/N/PE) System
Source
Connection
346/200 13.6, 13.8, 13.8 -- (+) 13.6, 13.8, 50 Hz, 144 V, 52 A
13.8 13.8
346/200 13.6, 13.8, 13.8 -- (+) 13.6, 13.8, 60 Hz, 144 V, 52 A
13.8 13.8
415/240 11.4, 11.6, 13.8 -- (+) 11.4, 11.6, 50 Hz, 144 V, 52 A
11.6 11.6
415/240 11.4, 11.6, 13.8 -- (+) 11.4, 11.6, 60 Hz, 144 V, 52 A
11.6 11.6
346/200 13.6, 13.8, 13.8 -- (+) 13.6, 13.8, 50 Hz, 158.4 V, 47.28 A
13.8 13.8
346/200 13.6, 13.8, 13.8 -- (+) 13.6, 13.8, 60 Hz, 158.4 V, 47.28 A
13.8 13.8
415/240 11.2, 11.4, 13.8 -- (+) 11.2, 11.4, 50 Hz, 158.4 V, 47.28 A
11.4 11.4
415/240 11.2, 11.4, 13.8 -- (+) 11.2, 11.4, 60 Hz, 158.4 V, 47.28 A

TRF No. IEC60950_1F


Enclosure_1 Page 46 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

11.4 11.4
Supplementary information: (+) Branch circuit breaker, Rated 50A.

2.1.1.5 c) TABLE: max. V, A, VA test P


1)
Voltage (rated) Current (rated) Voltage (max.) Current (max.) VA (max.)
(V) (A) (V) (A) (VA)
FETA7000T-48 (+) -- -- -- --
48V output 148.2 48.0 184.0 8171.8
52.8V output 148.2 52.8 184.0 9008.2
21.6V output 148.2 21.6 186.8 3937.39
FETA7000T-144 (+) -- -- -- --
144V output 52 144.0 59.0 8354.4
158.4V output 52 158.4 59.0 9204.0
64.8 output 52 64.8 60 3793.8
FETA7000ST-48 (2+) -- -- -- --
48V output 148.2 48.0 176.8 8377.3
52.8V output 148.2 52.8 176.4 9176.7
21.6V output 148.2 21.6 182.8 3820.2
FETA7000ST-144 (2+) -- -- -- --
144V output 52 144.0 58.4 8398.0
158.4V output 52 158.4 58.4 9122.1
64.8 output 52 64.8 60.8 3628.3
supplementary information:
(+) Power Source Connection: 3 PHASE, Star System
(2+) Power Source Connection: 3 PHASE, Star (3/N/PE) System

2.1.1.5 c) TABLE: stored energy N/A


2)
Capacitance C (µF) Voltage U (V) Energy E (J)
-- -- --
supplementary information:
--

TRF No. IEC60950_1F


Enclosure_1 Page 47 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

2.2 TABLE: evaluation of voltage limiting components in SELV circuits P


Component (measured between) max. voltage (V) Voltage Limiting Components
(normal operation)
V peak V d.c.
AUX output (CN2 (CN1) 1 pin to 2 pin) (+) (2+) -- 12.1 --
AUX output (CN2 (CN1) 1 pin to 2 pin) (2+) (3+) -- 12.1 --
Vss_ORMDS to Ground (5+) -- 156 --
Fault test performed on voltage limiting components Voltage measured (V) in SELV circuits
(V peak or V d.c.)
Vss_ORMDS to T701, 4 pin short (+) (5+) Maximum 27.99Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS1, PS3 damaged. (4+)
Vss_ORMDS to T701, 4 pin short (3+) (5+) Maximum 11.95Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS3 damaged. (4+)
Vss_ORMDS to D810 (K) short (+) (5+) Maximum 42.78Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS1, PS3 damaged. (4+)
Vss_ORMDS to D810 (K) short (3+) (5+) Maximum 11.99Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS3 damaged. (4+)
Vss_ORMDS to D811 (K) short (+) (5+) Maximum 32.8Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS1, PS3 damaged. (4+)
Vss_ORMDS to D811 (K) short (3+) (5+) Maximum 10.58Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS1, PS3 damaged. (4+)
Vss_ORMDS to T701, 2 pin (+) (5+) Maximum 26.0Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS1, PS3 damaged. (4+)
Vss_ORMDS to T701, 2 pin (3+) (5+) Maximum 12.05Vdc at between CN2 (CN1) 1 pin and
2 pin (2+) PS3 damaged. (4+)
R405 short (+) (2+) 12.1Vdc at between CN2 (CN1) 1 pin and 2 pin (2+)
Unit operated normal.
R405 short (2+) (3+) 12.2Vdc at between CN2 (CN1) 1 pin and 2 pin (2+)
Unit operated normal.

TRF No. IEC60950_1F


Enclosure_1 Page 48 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

supplementary information:
(+) CN2 (CN1) 1pin is connected to Ground.
(2+) For FETA7000T-144 (Maximum voltage within output voltage range: 158.4V, 47.28A)
(3+) CN2 (CN) 1 pin is not connected to Ground (floating).
(4+) Test was conducted three times.
(5+) For PS1 (FETA2500BA-48)
Note: This test was performed to confirm whether the output (non- SELV) of model FETA7000T-144 would
affect interface circuit (SELV). Interface circuits are connected to AUX circuits of the certified component
power supply FETA2500BA-48. Therefore, voltage between CN2 (CN1) 1 pin and 2 pin connected to AUX
circuits was measured as representative. This measurement covers all interface circuits.
Test performed on model FETA7000T-144 representative of model FETA7000ST-144 because secondary
circuits are identical.

2.5 TABLE: Limited power sources P


Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components Sample No. Uoc (V) Isc (A) VA
Meas. Limit Meas. Limit
-- -- -- -- -- -- --
supplementary information:
See clause 2.5.

2.10.2 Table: working voltage measurement P

Location RMS voltage (V) Peak voltage (V) Comments


FETA7000T-144 -- -- --
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to T line.
T301 of PS3 (FETA2500BA-48) -- -- --
1 to Gnd 251 588 Input voltage: 240V, 60Hz, (+)
2 to Gnd 245 420 Input voltage: 240V, 60Hz, (+)
1 to 3 253 652 Input voltage: 240V, 60Hz, (+)
1 to 4 219 548 Input voltage: 240V, 60Hz, (+)
1 to 5 295 764 Input voltage: 240V, 60Hz, (+)
3 to Gnd 33.5 57.2 Input voltage: 240V, 60Hz, (+)
4 to Gnd 68 166 Input voltage: 240V, 60Hz, (+)
5 to Gnd 68 166 Input voltage: 240V, 60Hz, (+)
1 to Gnd 247 600 Input voltage: 200V, 60Hz, (+)

TRF No. IEC60950_1F


Enclosure_1 Page 49 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1 to 5 291 760 Input voltage: 200V, 60Hz, (+)


1 to Gnd 251 608 Input voltage: 240V, 60Hz, (2+)
1 to 5 299 760 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 249 600 Input voltage: 200V, 60Hz, (2+)
1 to 5 296 776 Input voltage: 200V, 60Hz, (2+)
T701 of PS3 (FETA2500BA-48) -- -- --
5 to G, 5 to 2 387 712 Input voltage: 240V, 60Hz, (+)
7 to Gnd 312 432 Input voltage: 240V, 60Hz, (+)
8 to Gnd 167 384 Input voltage: 240V, 60Hz, (+)
9 to Gnd 167 360 Input voltage: 240V, 60Hz, (+)
5 to 1 387 704 Input voltage: 240V, 60Hz, (+)
5 to 3 378 688 Input voltage: 240V, 60Hz, (+)
5 to 4 385 388 Input voltage: 240V, 60Hz, (+)
1 to Gnd 1.42 3.44 Input voltage: 240V, 60Hz, (+)
2 to Gnd 12.1 14.4 Input voltage: 240V, 60Hz, (+)
3 to Gnd 16.9 33.6 Input voltage: 240V, 60Hz, (+)
4 to Gnd 21.4 48 Input voltage: 240V, 60Hz, (+)
5 to Gnd, 5 to 2 392 688 Input voltage: 200V, 60Hz, (+)
5 to Gnd, 5 to 2 387 696 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 392 688 Input voltage: 200V, 60Hz, (2+)
T301 of PS2 (FETA2500BA-48) -- -- --
1 to Gnd 303 852 Input voltage: 240V, 60Hz, (2+)
1 to 5 333 970 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 285 824 Input voltage: 200V, 60Hz, (2+)
1 to 5 313 940 Input voltage: 200V, 60Hz, (2+)
T701 of PS2 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 423 960 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 417 912 Input voltage: 200V, 60Hz, (2+)
T301 of PS1 (FETA2500BA-48) -- -- --
1 to Gnd 251 592 Input voltage: 240V, 60Hz, (2+)
1 to 5 288 688 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 248 600 Input voltage: 200V, 60Hz, (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 50 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1 to 5 278 672 Input voltage: 200V, 60Hz, (2+)


T701 of PS1 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 386 688 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 391 688 Input voltage: 200V, 60Hz, (2+)
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to S line.
T301 of PS3 (FETA2500BA-48) -- -- --
1 to Gnd 303 872 Input voltage: 240V, 60Hz, (2+)
1 to 5 343 1020 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 285 816 Input voltage: 200V, 60Hz, (2+)
1 to 5 325 1000 Input voltage: 200V, 60Hz, (2+)
T701 of PS3 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 423 976 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 417 920 Input voltage: 200V, 60Hz, (2+)
T301 of PS2 (FETA2500BA-48) -- -- --
1 to Gnd 251 592 Input voltage: 240V, 60Hz, (2+)
1 to 5 290 712 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 248 604 Input voltage: 200V, 60Hz, (2+)
1 to 5 283 724 Input voltage: 200V, 60Hz, (2+)
T701 of PS2 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 387 688 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 392 692 Input voltage: 200V, 60Hz, (2+)
T301 of PS1 (FETA2500BA-48) -- -- --
1 to Gnd 247 592 Input voltage: 240V, 60Hz, (2+)
1 to 5 277 648 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 252 616 Input voltage: 200V, 60Hz, (2+)
1 to 5 289 672 Input voltage: 200V, 60Hz, (2+)
T701 of PS1 -- -- --
5 to Gnd, 5 to 2 391 688 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 386 688 Input voltage: 200V, 60Hz, (2+)
PS3 (FETA2500BA-48) -- -- --
3 of PC204 to 6, 7, 8 of T301 245 448 Input voltage: 240V, 60Hz, (2+)
C125 to 9,10, 11 of T301 246 440 Input voltage: 240V, 60Hz, (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 51 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

L311 to 3, 4, 5 of T301 306 728 Input voltage: 240V, 60Hz, (2+)


PC331, PC332 Pri. to Sec. 236 360 Input voltage: 240V, 60Hz, (2+)
PC201, PC203, PC204 Pri. to 231 344 Input voltage: 240V, 60Hz, (2+)
Sec.
TR302 to 3, 4, 5 of T301 238 408 Input voltage: 240V, 60Hz, (2+)
TR702 to output terminal 425 968 Input voltage: 240V, 60Hz, (2+)
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to R line.
T301 of PS3 (FETA2500BA-48) -- -- --
1 to Gnd 251 592 Input voltage: 240V, 60Hz, (2+)
1 to 5 299 752 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 248 608 Input voltage: 200V, 60Hz, (2+)
1 to 5 296 768 Input voltage: 200V, 60Hz, (2+)
T701 of PS3 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 387 696 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 392 688 Input voltage: 200V, 60Hz, (2+)
T301 of PS2 (FETA2500BA-48) -- -- --
1 to Gnd 247 604 Input voltage: 240V, 60Hz, (2+)
1 to 5 282 700 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 253 612 Input voltage: 200V, 60Hz, (2+)
1 to 5 291 724 Input voltage: 200V, 60Hz, (2+)
T701 of PS2 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 386 692 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 392 708 Input voltage: 200V, 60Hz, (2+)
T301 of PS1 (FETA2500BA-48) -- -- --
1 to Gnd 304 860 Input voltage: 240V, 60Hz, (2+)
1 to 5 333 910 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 286 824 Input voltage: 200V, 60Hz, (2+)
1 to 5 308 860 Input voltage: 200V, 60Hz, (2+)
T701 of PS1 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 422 952 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 416 912 Input voltage: 200V, 60Hz, (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 52 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Power Source Connection: -- -- 3 PHASE, Star System,


T301 of PS3 (FETA2500BA-48) -- -- --
1 to Gnd 234 672 Input voltage: 240V, 60Hz, (+)
2 to Gnd 226 488 Input voltage: 240V, 60Hz, (+)
1 to 3 197 632 Input voltage: 240V, 60Hz, (+)
1 to 4 236 728 Input voltage: 240V, 60Hz, (+)
1 to 5 280 820 Input voltage: 240V, 60Hz, (+)
1 to Gnd 236 664 Input voltage: 200V, 60Hz, (+)
1 to 5 283 828 Input voltage: 200V, 60Hz, (+)
1 to Gnd 234 676 Input voltage: 240V, 60Hz, (2+)
1 to 5 286 828 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 236 656 Input voltage: 200V, 60Hz, (2+)
1 to 5 287 824 Input voltage: 200V, 60Hz, (2+)
T701 of PS3 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 378 784 Input voltage: 240V, 60Hz, (+)
7 to Gnd 297 496 Input voltage: 240V, 60Hz, (+)
8 to Gnd 132 232 Input voltage: 240V, 60Hz, (+)
9 to Gnd 131 208 Input voltage: 240V, 60Hz, (+)
5 to 1 378 780 Input voltage: 240V, 60Hz, (+)
5 to 3 368 756 Input voltage: 240V, 60Hz, (+)
5 to 4 376 776 Input voltage: 240V, 60Hz, (+)
5 to Gnd, 5 to 2 387 772 Input voltage: 200V, 60Hz, (+)
5 to Gnd, 5 to 2 387 772 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 377 780 Input voltage: 200V, 60Hz, (2+)
T301 of PS2 (FETA2500BA-48) -- -- --
1 to Gnd 234 668 Input voltage: 240V, 60Hz, (+)
1 to 5 271 796 Input voltage: 240V, 60Hz, (+)
1 to Gnd 235 660 Input voltage: 200V, 60Hz, (+)
1 to 5 269 772 Input voltage: 200V, 60Hz, (+)
1 to Gnd 232 652 Input voltage: 240V, 60Hz, (2+)
1 to 5 274 772 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 235 668 Input voltage: 200V, 60Hz, (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 53 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

1 to 5 273 772 Input voltage: 200V, 60Hz, (2+)


T701 of PS2 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 377 780 Input voltage: 240V, 60Hz, (+)
5 to Gnd, 5 to 2 387 780 Input voltage: 200V, 60Hz, (+)
5 to Gnd, 5 to 2 376 788 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 386 764 Input voltage: 200V, 60Hz, (2+)
T301 of PS1 (FETA2500BA-48) -- -- --
1 to Gnd 233 680 Input voltage: 240V, 60Hz, (+)
1 to 5 268 744 Input voltage: 240V, 60Hz, (+)
1 to Gnd 237 656 Input voltage: 200V, 60Hz, (+)
1 to 5 263 744 Input voltage: 200V, 60Hz, (+)
1 to Gnd 235 688 Input voltage: 240V, 60Hz, (2+)
1 to 5 273 752 Input voltage: 240V, 60Hz, (2+)
1 to Gnd 236 652 Input voltage: 200V, 60Hz, (2+)
1 to 5 268 732 Input voltage: 200V, 60Hz, (2+)
T701 of PS1 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 376 780 Input voltage: 240V, 60Hz, (+)
5 to Gnd, 5 to 2 385 764 Input voltage: 200V, 60Hz, (+)
5 to Gnd, 5 to 2 374 780 Input voltage: 240V, 60Hz, (2+)
5 to Gnd, 5 to 2 384 756 Input voltage: 200V, 60Hz, (2+)
FETA7000T-144 -- -- --
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to T line.
Main board -- -- --
TB112 to TB211 288 512 Input voltage: 240V, 60Hz, (2+)
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to S line.
Main board -- -- --
TB112 to TB211 159 168 Input voltage: 240V, 60Hz,
158.4V, 47.28A, (2+)
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to R line.
Main board -- -- --
TB112 to TB211 288 512 Input voltage: 240V, 60Hz, (2+)
1, 2 of TB3 to 1, 2 of TB4 159 166 Input voltage: 240V, 60Hz, (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 54 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

TB221 to 1, 2 of TB4 106 112 Input voltage: 240V, 60Hz, (2+)


TB231 to 1, 2 of TB4 52.2 60 Input voltage: 240V, 60Hz, (2+)
AUX1 to 1, 2 of TB4 0.418 1.68 Input voltage: 240V, 60Hz, (2+)
AUXG1 to 1, 2 of TB4 0.218 1.44 Input voltage: 240V, 60Hz, (2+)
AUX2 to 1, 2 of TB4 12 13.6 Input voltage: 240V, 60Hz, (2+)
AUXG2 to 1, 2 of TB4 0.4 2 Input voltage: 240V, 60Hz, (2+)
AUX3 to 1, 2 of TB4 0.41 1.6 Input voltage: 240V, 60Hz, (2+)
AUXG3 to 1, 2 of TB4 11.9 12.8 Input voltage: 240V, 60Hz, (2+)
Power Source Connection: -- -- 3 PHASE, Star System,
Main board -- -- --
TB112 to TB211 210 368 Input voltage: 240V, 60Hz, (2+)
FETA7000T-48 -- -- --
Power Source Connection: -- -- 3 PHASE, Delta System, Gnd
connected to S line.
T301 of PS3 (FETA2500BA-48) -- -- --
1 to Gnd 308 860 Input voltage: 240V, 60Hz, (3+)
1 to 5 349 1050 Input voltage: 240V, 60Hz, (3+)
1 to Gnd 290 856 Input voltage: 200V, 60Hz, (3+)
1 to 5 330 1000 Input voltage: 200V, 60Hz, (3+)
T701 of PS3 (FETA2500BA-48) -- -- --
5 to Gnd, 5 to 2 428 968 Input voltage: 240V, 60Hz, (3+)
5 to Gnd, 5 to 2 422 932 Input voltage: 200V, 60Hz, (3+)
supplementary information:
(+) Rated load (144V, 52A)
(2+) Maximum voltage within output voltage range (158.4V, 47.28A)
(3+) Maximum voltage within output voltage range (52.8V, 134.73A)

2.10.3 and TABLE: Clearance and creepage distance measurements P


2.10.4
Clearance (cl) and creepage U peak U r.m.s. Required cl cl Required cr cr
distance (cr) at/of/between: (V) (V) (mm) (mm) (mm) (mm)
Functional:
Component -- -- -- -- -- --
R to S, S to T of Terminal < 420 < 250 1.5 (1.8) 10.6 2.5 10.6
Block (TB1) (+)

TRF No. IEC60950_1F


Enclosure_1 Page 55 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

L1 to L2, L2 to L3 of Terminal < 420 < 250 1.5 (1.8) 10.6 2.5 10.6
Block (TB1) (3+)
PWB -- -- -- -- -- --
Trace at between R and S of < 420 < 250 1.5 (1.8) 4.3 2.5 4.3
Terminal Block (TB1) (+)
Trace at between L3 and L2 of < 420 < 250 1.5 (1.8) 5.3 2.5 5.3
Terminal Block (TB1) (3+)
Trace at Capacitors (C13) (+) < 420 < 250 1.5 (1.8) 4.0 2.5 4.0
Trace at between Capacitor < 420 < 250 1.5 (1.8) 5.3 2.5 5.3
(C13) and L2 of Terminal Block
(TB1) (3+)
Trace at between Capacitors < 420 < 250 1.5 (1.8) 3.1 2.5 3.1
(C11, C12) and L2 of Terminal
Block (TB1) (3+)
Trace T to R at Inductor (L11) < 420 < 250 1.5 (1.8) 4.0 2.5 4.0
(+)
Basic/supplementary:
PWB -- -- -- -- -- --
Trace at Capacitor (C14, C16) < 420 < 250 2.0 (2.3) 7.5 2.5 7.5
(+)
Trace at between FG of < 420 < 250 2.0 (2.3) 9.0 2.5 9.0
Terminal Block (TB2) and N of
Terminal Block (TB2) (3+)
Reinforced:
Unit -- -- -- -- -- --
Pri. to Sec.Screw of TR304 to 1050 349 5.8 (6.7) 7.0 7.0 28.0
T301 core (2+)
Pri. to Sec.Wire of Internal fan 1050 349 5.8 (6.7) 15.2 7.0 33.2
to T301 core (2+)
Pri. to Sec.T702 core to output 976 428 5.6 (6.4) 11.1 8.6 13.3
terminal (2+)
Pri. to Sec.TR702 to output 976 428 5.6 (6.4) 10.5 8.6 10.5
terminal (2+)
PWB -- -- -- -- -- --
Pri. to Sec. Trace at between 512 288 4.4 (5.1) 7.0 5.8 7.0
TB211 and TB112 (+)
Pri. to Sec. Trace at between < 420 < 250 4.0 (4.6) 8.5 5.0 8.5
PS1/+V out and L2 of Terminal
Block (TB1) (3+)
Pri. to Sec.Trace at PC204 448 245 4.2 (4.8) 6.2 4.9 6.2
3pin to T301 6, 7, 8pin (2+)

TRF No. IEC60950_1F


Enclosure_1 Page 56 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Pri. to Sec.Trace at C125 to 440 246 4.2 (4.8) 8.8 5.0 8.8
T301 9, 10, 11pin (2+)
Pri. to Sec.Trace at L311 pin to 728 306 5.0 (5.7) 8.5 6.2 8.5
T301 3, 4, 5pin (2+)
Pri. to Sec.Trace at Optical < 420 < 250 4.0 (4.6) 6.5 4.8 6.5
Isolators (PC201, PC203,
PC204, PC331, PC332) (2+)
Pri. to Sec.Trace at between 408 238 4.0 (4.6) 7.0 4.8 7.0
TR302 and T301 3, 4, 5pin (2+)
Pri. to Sec.Trace at C744 to 496 310 4.4 (5.1) 6.7 6.2 6.7
T701 1pin (2+)
Pri. to Sec. Trace at TR702 to 968 425 5.6 (6.4) 10.0 8.5 10.0
Output terminal trace (2+)
Supplementary information:
(+) FETA7000T-144/-48
(2+) FETA2500BA-48
(3+) FETA7000ST-144/-48
The Value in parentheses of above table is required clearance of operated at up to 3000 m sea level. The
multiplication factors of table A.2 of IEC 60664-1 applied. (1.14 times of required clearance of operated at
up to 2000 m sea level.)

2.10.5 TABLE: Distance through insulation measurements P


Distance through insulation (DTI) at/of: U peak U rms Test Required DTI DTI
(V) (V) voltage (mm) (mm)
(V)
Basic: < 420 250 DC -- 0.25
Insulation sheet between Main PWB and Chassis 2121
(AGC Polycarbonate Co., Ltd. Type
CARBOGLASS CFR230B)
Supplementary: < 420 250 DC 0.4 0.56
Insulation tube for CN31, CN32 and CN33 2121
(Nikkan Industries Co, Ltd. Type E-651U-1)
Supplementary information: --

4.3.8 TABLE: Batteries N/A


The tests of 4.3.8 are applicable only when appropriate battery -- --
data is not available
Is it possible to install the battery in a reverse polarity position? -- --
Non-rechargeable batteries Rechargeable batteries
Discharging Un- Charging Discharging Reversed
intentional charging
Meas. Manuf. charging Meas. Manuf. Meas. Manuf. Meas. Manuf.
current Specs. current Specs. current Specs. current Specs.

TRF No. IEC60950_1F


Enclosure_1 Page 57 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Max. -- -- -- -- -- -- -- -- --
current
during
normal
condition
Max. -- -- -- -- -- -- -- -- --
current
during fault
condition

Test results: -- Verdict


- Chemical leaks -- N/A
- Explosion of the battery -- N/A
- Emission of flame or expulsion of molten metal -- N/A
- Electric strength tests of equipment after completion of tests -- N/A
Supplementary information:

4.3.8 TABLE: Batteries N/A


Battery category .......................................... : --
Manufacturer ............................................... : --
Type / model ............................................... : --
Voltage ........................................................ : --
Capacity ...................................................... : --
Tested and Certified by (incl. Ref. No.) ....... : --
Circuit protection diagram: --
--

MARKINGS AND INSTRUCTIONS (1.7.13 )


Location of replaceable battery --
Language(s) …………………………………….: --
Close to the battery …………………………….: --
In the servicing instructions ……………………: --
In the operating instructions …………………..: --

4.5 TABLE: Thermal requirements P


Supply voltage (V) .......................... : See See See See -- 
below below below below
Ambient Tmin (C) ............................ : -- -- -- -- -- 
Ambient Tmax (C) ............................ : See See See See -- 
below below below below

TRF No. IEC60950_1F


Enclosure_1 Page 58 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Maximum measured temperature T of part/at......: T (C) Allowed


Tmax (C)
FETA7000T-144, Power Source Connection: -- -- -- -- -- --
3 PHASE, Delta System
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(144V, (144V, (144V, (144V,
52A) 52A) 52A) 52A)
Ambient 27 -- 27 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 67 80 58 71 -- 130 (TB1)
Terminal Block (TB3) 70 83 62 75 -- 130 (TB3)
Inductor (L11) 105 118 78 91 -- 140 (RTI)
Capacitor (C13) 78 91 66 79 -- 110 (C13)
Capacitor (C16) 73 86 62 75 -- 125 (C16)
Capacitor (C21) 74 87 65 78 -- 110 (C21)
PWB near TB211 77 90 67 80 -- 130 (PWB)
PWB near IC491 80 93 70 83 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 96 74 87 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 93 106 83 96 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 83 96 74 87 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 91 104 83 96 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 80 93 71 84 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 87 100 76 89 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 95 108 85 98 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 101 114 90 103 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 82 95 72 85 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 100 113 91 104 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 53 66 39 52 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 55 68 41 54 -- 140 (RTI)
48/PS2)

TRF No. IEC60950_1F


Enclosure_1 Page 59 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Inductor (L301) (FETA2500BA-48/PS2) 93 106 84 97 -- 150 (RTI)


PWB near TR302 (FETA2500BA-48/PS2) 77 90 67 80 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 80 93 70 83 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 84 97 75 88 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 92 105 82 95 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 81 94 72 85 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 99 112 90 103 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 89 102 80 93 -- 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% 50% -- --
load load load load
(144V, (144V, (144V, (144V,
26A) 26A) 26A) 26A)
Ambient 24 -- 24 -- -- --
Tma -- 60 -- 60 -- --
Terminal Block (TB1) 43 79 41 77 -- 130 (TB1)
Terminal Block (TB3) 45 81 44 80 -- 130 (TB3)
Inductor (L11) 57 93 50 86 -- 140 (RTI)
Capacitor (C13) 48 84 45 81 -- 110 (C13)
Capacitor (C16) 46 82 43 79 -- 125 (C16)
Capacitor (C21) 48 84 45 81 -- 110 (C21)
PWB near TB211 47 83 45 81 -- 130 (PWB)
PWB near IC491 53 89 51 87 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 50 86 48 84 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 53 89 51 87 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 55 91 53 89 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 58 94 55 91 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 54 90 51 87 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 56 92 52 88 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 54 90 51 87 -- 130
48/PS2) (Class F)

TRF No. IEC60950_1F


Enclosure_1 Page 60 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Sec. side (FETA2500BA- 57 93 54 90 -- 130


48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 55 91 52 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 62 98 59 95 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 32 68 29 65 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 33 69 30 66 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 62 98 59 95 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 49 85 46 82 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 54 90 51 87 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 88 50 86 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 54 90 52 88 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 55 91 52 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 63 99 60 96 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 98 59 95 -- 130 (PWB)
FETA7000T-144, Power Source Connection: -- -- -- -- -- --
3 PHASE, Star System,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(144V, (144V, (144V, (144V,
52A) 52A) 52A) 52A)
Ambient 24 -- 24 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 56 72 50 66 -- 130 (TB1)
Terminal Block (TB3) 58 74 53 69 -- 130 (TB3)
Inductor (L11) 84 100 66 82 -- 140 (RTI)
Capacitor (C13) 63 79 56 72 -- 110 (C13)
Capacitor (C16) 60 76 53 69 -- 125 (C16)
Capacitor (C21) 61 77 55 71 -- 110 (C21)
PWB near TB211 63 79 57 73 -- 130 (PWB)
PWB near IC491 66 82 60 76 -- 130 (PWB)

TRF No. IEC60950_1F


Enclosure_1 Page 61 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Pri. side (FETA2500BA- 67 83 61 77 -- 130


48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 74 90 69 85 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 71 87 65 81 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 76 92 72 88 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 66 82 61 77 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 72 88 66 82 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 76 92 69 85 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 81 97 74 90 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 69 85 63 79 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 83 99 77 93 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 43 59 34 50 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 45 61 36 52 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 78 94 73 89 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 62 78 56 72 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 66 82 61 77 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 68 84 63 79 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 74 90 68 84 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 69 85 64 80 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 82 98 77 93 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 74 90 69 85 -- 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% 50% -- --
load load load load
(144V, (144V, (144V, (144V,
26A) 26A) 26A) 26A)
Ambient 25 -- 25 -- -- --
Tma -- 60 -- 60 -- --
Terminal Block (TB1) 45 80 43 78 -- 130 (TB1)

TRF No. IEC60950_1F


Enclosure_1 Page 62 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Terminal Block (TB3) 47 82 45 80 -- 130 (TB3)


Inductor (L11) 58 93 51 86 -- 140 (RTI)
Capacitor (C13) 50 85 46 81 -- 110 (C13)
Capacitor (C16) 48 83 45 80 -- 125 (C16)
Capacitor (C21) 49 84 47 82 -- 110 (C21)
PWB near TB211 49 84 46 81 -- 130 (PWB)
PWB near IC491 54 89 52 87 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 86 48 83 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 54 89 51 86 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 91 53 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 59 94 56 91 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 55 90 52 87 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 57 92 53 88 -- 130 (RTI)
Transformer (T301 coil Pri. side (FETA2500BA- 55 90 52 87 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 59 94 56 91 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 56 91 53 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 64 99 60 95 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 34 69 30 65 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 35 70 31 66 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 64 99 61 96 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 50 85 47 82 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 56 91 53 88 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 54 89 51 86 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 56 91 53 88 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 57 92 54 89 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 64 99 61 96 -- 130 (PWB)

TRF No. IEC60950_1F


Enclosure_1 Page 63 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

PWB near T701 (FETA2500BA-48/PS3) 63 98 60 95 -- 130 (PWB)


FETA7000T-48, Power Source Connection: -- -- -- -- -- --
3 PHASE, Delta System,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(48V, (48V, (48V, (48V,
148.2A) 148.2A) 148.2A) 148.2A)
Ambient 26 -- 27 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 61 75 56 69 -- 130 (TB1)
Terminal Block (TB3) 75 89 71 84 -- 130 (TB3)
Inductor (L11) 95 109 74 87 -- 140 (RTI)
Capacitor (C13) 70 84 62 75 -- 110 (C13)
Capacitor (C16) 67 81 60 73 -- 125 (C16)
Capacitor (C21) 74 88 68 81 -- 110 (C21)
PWB near TB211 69 83 62 75 -- 130 (PWB)
PWB near IC491 72 86 66 79 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 75 89 69 82 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 84 98 78 91 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 78 92 72 85 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 86 100 81 94 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 76 90 69 82 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 79 93 72 85 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 81 95 75 88 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 90 104 83 96 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 78 92 72 85 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 90 104 84 97 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 46 60 37 50 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 47 61 38 51 -- 140 (RTI)
48/PS2)

TRF No. IEC60950_1F


Enclosure_1 Page 64 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Inductor (L301) (FETA2500BA-48/PS2) 85 99 79 92 -- 150 (RTI)


PWB near TR302 (FETA2500BA-48/PS2) 69 83 62 75 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 78 92 72 85 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 78 92 72 85 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 86 100 79 92 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 76 90 70 83 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 91 105 85 98 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 83 97 76 89 -- 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% 50% -- --
load load load load
(48V, (48V, (48V, (48V,
74.1A) 74.1A) 74.1A) 74.1A)
Ambient 26 -- 27 -- -- --
Tma -- 60 -- 60 -- --
Terminal Block (TB1) 45 79 44 77 -- 130 (TB1)
Terminal Block (TB3) 49 83 48 81 -- 130 (TB3)
Inductor (L11) 57 91 52 85 -- 140 (RTI)
Capacitor (C13) 49 83 47 80 -- 110 (C13)
Capacitor (C16) 47 81 46 79 -- 125 (C16)
Capacitor (C21) 50 84 49 82 -- 110 (C21)
PWB near TB211 48 82 47 80 -- 130 (PWB)
PWB near IC491 53 87 52 85 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 85 50 83 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 54 88 52 85 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 90 55 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 58 92 57 90 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 56 90 55 88 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 55 89 54 87 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 53 87 52 85 -- 130
48/PS2) (Class F)

TRF No. IEC60950_1F


Enclosure_1 Page 65 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Sec. side (FETA2500BA- 57 91 56 89 -- 130


48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 58 92 56 89 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 61 95 60 93 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 33 67 31 64 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 34 68 32 65 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 62 96 60 93 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 49 83 48 81 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 58 92 56 89 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 53 87 52 85 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 55 89 54 87 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 90 55 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 62 96 61 94 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 96 61 94 -- 130 (PWB)
FETA7000T-48, Power Source Connection: -- -- -- -- -- --
3 PHASE, Star System,
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(48V, (48V, (48V, (48V,
148.2A) 148.2A) 148.2A) 148.2A)
Ambient 24 -- 25 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 61 77 53 68 -- 130 (TB1)
Terminal Block (TB3) 74 90 67 82 -- 130 (TB3)
Inductor (L11) 93 109 70 85 -- 140 (RTI)
Capacitor (C13) 68 84 59 74 -- 110 (C13)
Capacitor (C16) 65 81 57 72 -- 125 (C16)
Capacitor (C21) 73 89 65 80 -- 110 (C21)
PWB near TB211 67 83 59 74 -- 130 (PWB)
PWB near IC491 71 87 63 78 -- 130 (PWB)

TRF No. IEC60950_1F


Enclosure_1 Page 66 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Transformer (T301) coil Pri. side (FETA2500BA- 73 89 66 81 -- 130


48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 82 98 75 90 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 76 92 69 84 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 84 100 78 93 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 74 90 66 81 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 77 93 68 83 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 79 95 71 86 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 88 104 80 95 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 77 93 69 84 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 88 104 81 96 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 45 61 35 50 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 47 63 36 51 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 84 100 76 91 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 67 83 59 74 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 76 92 68 83 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 77 93 69 84 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 84 100 76 91 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 74 90 67 82 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 90 106 83 98 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 82 98 73 88 -- 130 (PWB)
Supply voltage/ frequency 180Vac 180Vac 264Vac 264Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 50% 50% 50% 50% -- --
load load load load
(48V, (48V, (48V, (48V,
74.1A) 74.1A) 74.1A) 74.1A)
Ambient 25 -- 25 -- -- --
Tma -- 60 -- 60 -- --
Terminal Block (TB1) 45 80 43 78 -- 130 (TB1)

TRF No. IEC60950_1F


Enclosure_1 Page 67 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Terminal Block (TB3) 48 83 47 82 -- 130 (TB3)


Inductor (L11) 56 91 50 85 -- 140 (RTI)
Capacitor (C13) 48 83 46 81 -- 110 (C13)
Capacitor (C16) 47 82 44 79 -- 125 (C16)
Capacitor (C21) 50 85 48 83 -- 110 (C21)
PWB near TB211 47 82 45 80 -- 130 (PWB)
PWB near IC491 53 88 50 85 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 50 85 48 83 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 53 88 51 86 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 91 53 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 57 92 55 90 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 56 91 53 88 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 55 90 52 87 -- 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 53 88 50 85 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 56 91 54 89 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 57 92 55 90 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 60 95 58 93 -- 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 33 68 29 64 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 34 69 30 65 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 61 96 58 93 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 48 83 46 81 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 57 92 55 90 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 87 50 85 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 55 90 52 87 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 91 53 88 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 62 97 59 94 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 62 97 59 94 -- 130 (PWB)

TRF No. IEC60950_1F


Enclosure_1 Page 68 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

FETA7000ST-144, Power Source Connection: 3 -- -- -- -- -- --


PHASE, (3/N/PE) System,
Supply voltage/ frequency 311Vac 311Vac 457Vac 457Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(144V, (144V, (144V, (144V,
52A) 52A) 52A) 52A)
Ambient 28 -- 26 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 63 75 55 69 -- 130 (TB1)
Terminal Block (TB3) 61 73 54 68 -- 130 (TB3)
Capacitor (C11) 72 84 62 76 -- 110 (C11)
Capacitor (C15) 70 82 59 73 -- 125 (C15)
Capacitor (C21) 67 79 58 72 -- 110 (C21)
PWB near TB211 78 90 67 81 -- 130 (PWB)
PWB near IC491 78 90 68 82 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 95 74 88 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 83 95 74 88 -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 76 88 66 80 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 94 106 85 99 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 70 82 59 73 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 79 91 68 82 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 86 98 76 90 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 80 92 69 83 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 106 118 96 110 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 75 87 64 78 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 85 97 74 88 -- 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 54 66 38 52 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 53 65 38 52 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 65 77 43 57 -- 150 (RTI)

TRF No. IEC60950_1F


Enclosure_1 Page 69 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

PWB near TR302 (FETA2500BA-48/PS2) 77 89 66 80 -- 130 (PWB)


Transformer (T301) coil Pri. side (FETA2500BA- 73 85 62 76 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 81 93 74 88 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 78 90 70 84 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 92 104 84 98 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 69 81 61 75 -- 130 (PWB)
Supply voltage/ frequency 311Vac 311Vac -- -- -- --
/60Hz /60Hz
Condition 50% 50% -- -- -- --
load load
(144V, (144V,
26A) 26A)
Ambient 24 -- -- -- -- --
Tma -- 60 -- -- -- --
Terminal Block (TB1) 43 79 -- -- -- 130 (TB1)
Terminal Block (TB3) 43 79 -- -- -- 130 (TB3)
Capacitor (C11) 49 85 -- -- -- 110 (C11)
Capacitor (C15) 47 83 -- -- -- 125 (C15)
Capacitor (C21) 46 82 -- -- -- 110 (C21)
PWB near TB211 49 85 -- -- -- 130 (PWB)
PWB near IC491 54 90 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 52 88 -- -- -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 52 88 -- -- -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 54 90 -- -- -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 60 96 -- -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 50 86 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 54 90 -- -- -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 57 93 -- -- -- 110
(Class B)

TRF No. IEC60950_1F


Enclosure_1 Page 70 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

PWB near T301 (FETA2500BA-48/PS2) 68 104 -- -- -- 130 (PWB)


PWB near T701 (FETA2500BA-48/PS2) 53 89 -- -- -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 57 93 -- -- -- 130
(TB101)
Inductor (L101) (FETA2500BA-48/PS2) 33 69 -- -- -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 34 70 -- -- -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 41 77 -- -- -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 52 88 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 47 83 -- -- -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 51 87 -- -- -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 55 91 -- -- -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 59 95 -- -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 50 86 -- -- -- 130 (PWB)
FETA7000ST-48, Power Source Connection: 3 -- -- -- -- -- --
PHASE, (3/N/PE) System
Supply voltage/ frequency 311Vac 311Vac 457Vac 457Vac -- --
/60Hz /60Hz /60Hz /60Hz
Condition 100% 100% 100% 100% -- --
load load load load
(48V, (48V, (48V, (48V,
148.2A) 148.2A) 148.2A) 148.2A)
Ambient 23 -- 22 -- -- --
Tma -- 40 -- 40 -- --
Terminal Block (TB1) 56 73 48 66 -- 130 (TB1)
Terminal Block (TB3) 66 83 59 77 -- 130 (TB3)
Capacitor (C11) 62 79 52 70 -- 110 (C11)
Capacitor (C15) 65 82 55 73 -- 125 (C15)
Capacitor (C21) 64 81 56 74 -- 110 (C21)
PWB near TB211 71 88 61 79 -- 130 (PWB)
PWB near IC491 71 88 61 79 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 69 86 60 78 -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 75 92 66 84 -- 130
48/PS1) (Class F)

TRF No. IEC60950_1F


Enclosure_1 Page 71 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Transformer (T701) coil (FETA2500BA-48/PS1) 72 89 63 81 -- 110


(Class B)
PWB near T301 (FETA2500BA-48/PS1) 89 106 81 99 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 67 84 58 76 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 71 88 61 79 -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 79 96 68 86 -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 74 91 64 82 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 97 114 87 105 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 69 86 58 76 -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 78 95 67 85 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 48 65 34 52 -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 48 65 34 52 -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 60 77 40 58 -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 70 87 60 78 -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 65 82 57 75 -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 74 91 66 84 -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 73 90 65 83 -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 84 101 77 95 -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 64 81 56 74 -- 130 (PWB)
Supply voltage/ frequency 311Vac 311Vac -- -- -- --
/60Hz /60Hz
Condition 50% 50% -- -- -- --
load load
(48V, (48V,
74.1A) 74.1A)
Ambient 24 -- -- -- -- --
Tma -- 60 -- -- -- --
Terminal Block (TB1) 44 80 -- -- -- 130 (TB1)
Terminal Block (TB3) 47 83 -- -- -- 130 (TB3)
Capacitor (C11) 48 84 -- -- -- 110 (C11)
Capacitor (C15) 49 85 -- -- -- 125 (C15)

TRF No. IEC60950_1F


Enclosure_1 Page 72 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Capacitor (C21) 48 84 -- -- -- 110 (C21)


PWB near TB211 50 86 -- -- -- 130 (PWB)
PWB near IC491 54 90 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- -- 130
48/PS1) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 53 89 -- -- -- 130
48/PS1) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS1) 56 92 -- -- -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS1) 62 98 -- -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 53 89 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 51 87 -- -- -- 130
48/PS2) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 55 91 -- -- -- 130
48/PS2) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS2) 58 94 -- -- -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS2) 67 103 -- -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 55 91 -- -- -- 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 58 94 -- -- -- 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 35 71 -- -- -- 140 (RTI)
Inductor (L102) near R101 (FETA2500BA- 35 71 -- -- -- 140 (RTI)
48/PS2)
Inductor (L301) (FETA2500BA-48/PS2) 42 78 -- -- -- 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 53 89 -- -- -- 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 48 84 -- -- -- 130
48/PS3) (Class F)
Transformer (T301) coil Sec. side (FETA2500BA- 52 88 -- -- -- 130
48/PS3) (Class F)
Transformer (T701) coil (FETA2500BA-48/PS3) 56 92 -- -- -- 110
(Class B)
PWB near T301 (FETA2500BA-48/PS3) 59 95 -- -- -- 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 52 88 -- -- -- 130 (PWB)
Supplementary information: --
Temperature T of winding: t1 (°C) R1 () t2 (°C) R2 () T (C) Allowed Insulatio
Tmax (C) n class
-- -- -- -- -- -- -- --
Supplementary information: --

TRF No. IEC60950_1F


Enclosure_1 Page 73 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

4.5.5 TABLE: Ball pressure test of thermoplastic parts P


Allowed impression diameter (mm) ..................... :  2 mm 
Part Test temperature Impression diameter
(C) (mm)
PBT of Bobbin (Core Case) of L11 133 1.0
(Wintech Polymer Ltd. Type CRN7000)
PBT of Base of TB1, TB3 125 0.8
(Wintech Polymer Ltd. Type 3316)
Supplementary information: --

4.7 TABLE: Resistance to fire P


Part Manufacturer of Type of material Thickness Flammability Evidence
material (mm) class
-- -- -- -- -- --
Supplementary information: See Table 1.5.1 List of critical components.

5.1 TABLE: touch current measurement P

Measured between: Measured Limit Comments/conditions


(mA) (mA)
Power Source Connection: -- -- 3 PHASE, Delta System, (#)
Ground (Chassis) 2.760 (+) 3.5 Switch “e” =open; Comp. C14 is
disconnected. Gnd connected to R line.
Ground (Chassis) 2.672 (2+) 3.5 Switch “e” =open; Comp. C15 is
disconnected. Gnd connected to R line.
Ground (Chassis) 3.166 (3+) 3.5 Switch “e” =open; Comp. C16 is
disconnected. Gnd connected to R line.
Ground (Chassis) 2.694 (4+) 3.5 Switch “e” =open; Comp. C14 is
disconnected. Gnd connected to S line.
Ground (Chassis) 3.010 (5+) 3.5 Switch “e” =open; Comp. C15 is
disconnected. Gnd connected to S line.
Ground (Chassis) 2.740 (6+) 3.5 Switch “e” =open; Comp. C16 is
disconnected. Gnd connected to S line.
Ground (Chassis) 3.084 (7+) 3.5 Switch “e” =open; Comp. C14 is
disconnected. Gnd connected to T line.
Ground (Chassis) 2.688 (8+) 3.5 Switch “e” =open; Comp. C15 is
disconnected. Gnd connected to T line.
Ground (Chassis) 2.748 (9+) 3.5 Switch “e” =open; Comp. C16 is
disconnected. Gnd connected to T line.

TRF No. IEC60950_1F


Enclosure_1 Page 74 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Power Source Connection: -- -- 3 PHASE, Star System, (#)


Ground (Chassis) 0.2550 (10+) 3.5 Switch “e” =open; P1 – N,
Comp. C14 is disconnected.
Ground (Chassis) 0.2496 (11+) 3.5 Switch “e” =open; P1 – R,
Comp. C14 is disconnected.
Ground (Chassis) 0.2244 (12+) 3.5 Switch “e” =open; P1 – N,
Comp. C15 is disconnected.
Ground (Chassis) 0.2226 (13+) 3.5 Switch “e” =open; P1 – R,
Comp. C15 is disconnected.
Ground (Chassis) 0.2638 (14+) 3.5 Switch “e” =open; P1 – N,
Comp. C16 is disconnected.
Ground (Chassis) 0.2462 (15+) 3.5 Switch “e” =open; P1 – R,
Comp. C16 is disconnected.
Power Source Connection: -- -- 3 PHASE, (3/N/PE) System, (##)
Ground (Chassis) 0.276 (16+) 3.5 Switch “e” =open; P1 – N,
Comp. C15 is disconnected.
Ground (Chassis) 0.272 (17+) 3.5 Switch “e” =open; P1 – R,
Comp. C15 is disconnected.
supplementary information:
(#) 264Vac, 60Hz, model FETA7000T-144 is representative of model FETA7000T-48.
(##) 457Vac, 60Hz, model FETA7000ST-144 is representative of model FETA7000ST-48.
(+) 1.380V / 500 ohm
(2+) 1.336V / 500 ohm
(3+) 1.583V / 500 ohm
(4+) 1.347V / 500 ohm
(5+) 1.505V / 500 ohm
(6+) 1.370V / 500 ohm
(7+) 1.542V / 500 ohm
(8+) 1.344V / 500 ohm
(9+) 1.374V / 500 ohm
(10+) 0.1275V / 500 ohm
(11+) 0.1248V / 500 ohm
(12+) 0.1122V / 500 ohm
(13+) 0.1113V / 500 ohm
(14+) 0.1319V / 500 ohm
(15+) 0.1231V / 500 ohm
(16+) 0.138V / 500 ohm
(17+) 0.136V / 500 ohm

5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests P

TRF No. IEC60950_1F


Enclosure_1 Page 75 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Test voltage applied between: Voltage shape Test voltage Breakdo


(AC, DC, (V) wn
impulse, surge) Yes / No
Functional:
-- -- -- --
Basic/supplementary:
Primary / Ground DC 3393 No
Reinforced:
Primary / Secondary DC 4243 No
Supplementary information: --

5.3 TABLE: Fault condition tests P


Ambient temperature (C) ................................... : See below. 
Power source for EUT: Manufacturer, model/type, NF Electronic Instruments 
output rating ........................................................ : ES18000W, Output 18KVA
Component Fault Supply Test Fuse # Fuse Observation
No. voltage time current
(V) (A)
Component -- -- -- -- -- --
Failure Test
FETA7000T- -- -- -- -- -- --
144
PC481 Short 264Vac 15 (+) 18.5, Unit operated normal.
(Primary /60Hz minutes 18.5, NB, NC ,NT, Ambient: 25 °C
side) (2+) 18.5
PC481 Short 264Vac 15 (+) 18.5, Unit operated normal.
(Secondary /60Hz minutes 18.5, NB, NC, NT, Ambient: 25 °C
side) (2+) 18.5
PC482 Short 264Vac 15 (+) 18.5, Unit operated normal.
(Primary /60Hz minutes 18.5, NB, NC, NT, Ambient: 25 °C
side) (2+) 18.5
PC482 Short 264Vac 15 (+) 18.5, Unit operated normal.
(Secondary /60Hz minutes 18.5, NB, NC, NT, Ambient: 25 °C
side) (2+) 18.5
PC461 Short 264Vac 1 (+) -- Unit shit down no damaged.
(Primary /60Hz second NB, NC, NT, Ambient: 25 °C
side) (2+)
PC461 Short 264Vac 15 (+) 18.5, Unit operated normal.
(Secondary /60Hz minutes 18.5, NB, NC, NT, Ambient: 25 °C
side) (2+) 18.5

TRF No. IEC60950_1F


Enclosure_1 Page 76 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

TR491 Short 264Vac 15 (+) 15.0, Output down: 144V, 52A >124V
(C to E) /60Hz minutes 17.0, 52A.
(2+) 15.0 Unit kept the operation aftre short
test.
NB, NC, NT, Ambient: 25 °C
TR491 Short 264Vac 15 (+) 15.0, Output down: 144V, 52A >128V
(E to B) /60Hz minutes 17.0, 52A.
(2+) 15.0 Unit kept the operation aftre short
test.
NB, NC, NT, Ambient: 25 °C
Abnormal -- -- -- -- -- --
Operation
Test
FETA7000T- -- -- -- -- -- --
144
FAN of PS2 Stalled 180 Vac 5 (+) -- After 5 seconds. unit shut down
/60Hz seconds no damaged.
(2+) NB, NC, NT, Ambient: 25 °C
Phase open opened 180 Vac 1 (+) -- Unit shut down no damaged.
(S line) /60Hz second NB, NC, NT, Ambient: 25 °C
(2+)
Phase open opened 180 Vac 1 (+) -- Unit shut down no damaged.
(S line) /60Hz second NB, NC, NT, Ambient: 25 °C
(3+)
Power -- -- -- -- -- --
Supply
output
short- circuit
/overload
Test
FETA7000T- -- -- -- -- -- --
48
52.8V output Short 264 Vac 1 (+) -- Unit shut down no damaged.
/60Hz second NB, NC, NT, Ambient: 25 °C
(2+)

TRF No. IEC60950_1F


Enclosure_1 Page 77 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

52.8V output Overload 264 Vac 7 hours, (+) 22.0, Maximum continuous temperature
/60Hz 21 21.5, was obtained at 52.07V, 173A
(2+) minutes. 22.0 load.
T301 coil (Sec. side) of PS1:
101 °C.
T701 coil of PS1: 81 °C.
T301 coil (Sec. side) of PS2:
107 °C.
T701 coil of PS2: 82 °C.
T301 coil (Sec. side) of PS3:
101 °C.
T701 coil of PS3: 80 °C.
Then temperature decreased
when further loaded over 173 A
load.
NB, NC, NT, Ambient: 25°C
FETA7000T- -- -- -- -- -- --
144
158.4V Short 264 Vac 1 (+) -- Unit shut down no damaged.
output /60Hz seccond NB, NC, NT, Ambient: 25 °C
(2+)
158.4V Overload 264 Vac 4 hours, (+) 22.0, Maximum continuous temperature
output /60Hz 48 22.0, was obtained at 157.6 V, 56.8 A.
(2+) minutes. 22.0 load.
T301 coil (Sec. side) of PS1:
101 °C.
T701 coil of PS1: 81 °C.
T301 coil (Sec. side) of PS2:
108 °C.
T701 coil of PS2: 84 °C.
T301 coil (Sec. side) of PS3:
100 °C.
T701 coil of PS3: 80 °C.
Then temperature decreased
when further loaded over 56.8 A
load.
NB, NC, NT, Ambient: 26 °C

TRF No. IEC60950_1F


Enclosure_1 Page 78 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

Supplementary information:
(+) Branch circuit breaker, Rated 50A.
(2+) Power Source Connection: 3 PHASE, Delta System,
(3+) Power Source Connection: 3 PHASE, Star System,
CT - Constant temperatures were obtained
NB - No indication of dielectric breakdown after 60 seconds
NC - Cheesecloth remained intact
NT - Tissue paper remained intact
Test performed on models FETA7000T-144 and FETA7000T-48 representative of models FETA7000ST-
144 and FETA7000ST-48 because the difference between each other is only the difference between the
primary part and the supply power source at a level that is not affected by the above test results.

C.2 TABLE: transformers P


Loc. Tested Working Working Require Required Required Required
insulation voltage voltage d clearance creepage distance thr.
peak / V rms / V electric / mm distance / insul.
strength mm
(2.10.2) (2.10.2) (2.10.3) (2.10.4) (2.10.5)
(5.2)
FETA2500BA- -- -- -- -- -- -- --
48
T301 1) -- -- -- -- -- -- --
Pri. to Sec. Reinforced 1050 349 AC 3000 5.8 (6.7) 7.0 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced 1050 349 AC 3000 5.8 (6.7) 7.0 Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
T701 3) -- -- -- -- -- -- --
Pri. to Sec. Reinforced 976 428 AC 3000 4.8 (5.5) 8.6 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced 976 428 AC 3000 4.8 (5.5) 8.6 Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
Loc. Tested Test Measure Measured Measured
insulation voltage/ d creepage distance thr.
V clearance dist./ mm insul. / mm;
/ mm number of
layers
FETA2500BA- -- -- -- -- --
48

TRF No. IEC60950_1F


Enclosure_1 Page 79 of 80 Report No. 4788327671

IEC 60950-1
Clause Requirement + Test Result - Remark Verdict

T301 1) -- -- -- -- --
Pri. to Sec. Reinforced AC 3000 11.4 11.4 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced AC 3000 -- 2) -- 2) Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
T701 3) -- -- -- -- --
Pri. to Sec. Reinforced AC 3000 12.7 12.7 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced AC 3000 -- 4) -- 4) Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
supplementary information:
1)
Core of Transformer T301 is considered as Sec.
2)
Pri. wire is used Triple Insulation Wire.
3)
Core of Transformer T701 is considered as Pri.
4)
Sec. wire is used Triple Insulation Wire.
Note: The Value in parentheses of above table is required clearance of operated at up to 3000 m sea level.
The multiplication factors of table A.2 of IEC 60664-1 applied. (1.14 times of required clearance of operated
at up to 2000 m sea level.)

This table is for certified power supply: model FETA2500BA-48. But this table was confirmed, because
working voltage of model FETA2500BA-48 increased in combination with 3 PHASE power supply
connection.

C.2 TABLE: transformers N/A


--

TRF No. IEC60950_1F


Enclosure_1 Page 80 of 80 Report No. 4788327671

List of test equipment used:


A completed list of used test equipment shall be provided in the Test Reports when a Manufacturer Testing
Laboratory according to TMP/CTF stage 1 or WMT/CTF stage 2 procedure has been used.

Clause Measurement / Testing / measuring equipment / Range used Calibration date


testing material used
-- -- -- -- --
Enclosure_1 Page 1 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60950-1


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Information technology equipment – Safety –
Part 1: General requirements
Differences according to................ : EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
Attachment Form No. ..................... : EU_GD_IEC60950_1F
Attachment Originator ................... : SGS Fimko Ltd
Master Attachment ......................... : Date 2014-02
Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Clauses, subclauses, notes, tables and figures which are additional to those in P
IEC60950-1 and it´s amendmets are prefixed “Z”
Contents Add the following annexes: P
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZB (normative) Special national conditions
(A2:2013) Annex ZD (informative) IEC and CENELEC code designations for
flexible cords
General Delete all the “country” notes in the reference document (IEC 60950-1:2005) P
according to the following list:
1.4.8 Note 2 1.5.1 Note 2 & 3 1.5.7.1 Note
1.5.8 Note 2 1.5.9.4 Note 1.7.2.1 Note 4, 5 & 6
2.2.3 Note 2.2.4 Note 2.3.2 Note
2.3.2.1 Note 2 2.3.4 Note 2 2.6.3.3 Note 2 & 3
2.7.1 Note 2.10.3.2 Note 2 2.10.5.13 Note 3
3.2.1.1 Note 3.2.4 Note 3. 2.5.1 Note 2
4.3.6 Note 1 & 2 4.7 Note 4 4.7.2.2 Note
4.7.3.1 Note 2 5.1.7.1 Note 3 & 4 5.3.7 Note 1
6 Note 2 & 5 6.1.2.1 Note 2 6.1.2.2 Note
6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note
7.1 Note 3 7.2 Note 7.3 Note 1 & 2
G.2.1 Note 2 Annex H Note 2
General Delete all the “country” notes in the reference document (IEC 60950- P
(A1:2010) 1:2005/A1:2010) according to the following list:
1.5.7.1 Note 6.1.2.1 Note 2
6.2.2.1 Note 2 EE.3 Note
Enclosure_1 Page 2 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
General Delete all the “country” notes in the reference document (IEC 60950- P
(A2:2013)
1:2005/A2:2013) according to the following list:
2.7.1 Note * 2.10.3.1 Note 2
6.2.2. Note
* Note of secretary: Text of Common Modification remains unchanged.
1.1.1 Replace the text of NOTE 3 by the following. P
(A1:2010) NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia
equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN
60065 applies.
1.3.Z1 Add the following subclause: Not such equipment. N/A
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed
as to present no danger when used for its intended
purpose, either in normal operating conditions or
under fault conditions, particularly providing
protection against exposure to excessive sound
pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in
EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part
1: General method for “one package equipment”, and in
EN 50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment -
Maximum sound pressure level measurement
methodology and limit considerations - Part 2: Guidelines
to associate sets with headphones coming from different
manufacturers.
(A12:2011)
In EN 60950-1:2006/A12:2011 N/A
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010
1.5.1 Add the following NOTE: Considered. P
NOTE Z1 The use of certain substances in electrical and See Enclosure Supplement
electronic equipment is restricted within the EU: see Id. 5-03
Directive 2002/95/EC.
(Added New Directive 2011/65/11 *
info*)
1.7.2.1 In addition, for a PORTABLE SOUND SYSTEM, the Not such equipment. N/A
(A1:2010) instructions shall include a warning that excessive
sound pressure from earphones and headphones can
cause hearing loss.
1.7.2.1 In EN 60950-1:2006/A12:2011 N/A
(A12.2011)
Delete NOTE Z1 and the addition for Portable Sound
System.
Add the following clause and annex to the existing
standard and amendments.
Enclosure_1 Page 3 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Zx Protection against excessive sound pressure from personal music N/A
players
Zx.1 General Not such equipment. N/A
This sub-clause specifies requirements for protection
against excessive sound pressure from personal
music players that are closely coupled to the ear. It
also specifies requirements for earphones and
headphones intended for use with personal music
players.
A personal music player is a portable equipment 
for personal use, that:
is designed to allow the user to listen to recorded
or broadcast sound or video; and
primarily uses headphones or earphones that can
be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.

A personal music player and earphones or


headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected to
an external amplifier; or
while the headphones or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.

The requirements do not apply to:


hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.
Enclosure_1 Page 4 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
analogue personal music players (personal
music players without any kind of digital
processing of the sound signal) that are brought
to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a few
years it will no longer exist. This exemption will not be extended to
other technologies.

For equipment which is clearly designed or intended


for use by young children, the limits of EN 71-1
apply.
Zx.2 Equipment requirements N/A
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal music
player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured
while playing the fixed “programme simulation
noise” as described in EN 50332-1; and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this clause,
the 30 s A-weighted equivalent sound pressure level LAeq,T is
meant. See also Zx.5 and Annex Zx.

All other equipment shall:


a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and

Enclosure_1 Page 5 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding
those mentioned above. Any means used shall
be acknowledged by the user before
activating a mode of operation which allows for
an acoustic output exceeding those mentioned
above. The acknowledgement does not need to
be repeated more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening time,
independent how often and how long the personal music player
has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with
Its listening device), the acoustic output shall be
≤ 100 dBA measured while playing the fixed
“programme simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song
is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.
NOTE 4 Classical music typically has an average sound pressure
(long term LAeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable to
analyse the song and compare it with the programme simulation
noise, the warning does not need to be given as long as the
average sound pressure of the song is below the basic limit of 85
dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the song
is not above the basic limit of 85 dBA.
Enclosure_1 Page 6 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict

Zx.3 Warning N/A


The warning shall be placed on the equipment, or on
the packaging, or in the instruction manual and shall
consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and
the following wording, or similar:
“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”

Figure 1 – Warning label (IEC 60417-6044)

Alternatively, the entire warning may be given


through the equipment display during use, when the
user is asked to acknowledge activation of the
higher level.
Zx.4 Requirements for listening devices (headphones and earphones) N/A
Zx.4.1 Wired listening devices with analogue N/A
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for example
built-in volume level control).

NOTE The values of 94 dBA – 75 mV correspond with 85dBA –


27 mV and 100 dBA – 150 mV.
Enclosure_1 Page 7 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
Zx.4.2 Wired listening devices with digital input N/A
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall be
≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
NOTE An example of a wired listening device with digital input is
a USB headphone.
Zx.4.3 Wireless listening devices N/A
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth
headphone.
Zx.5 Measurement methods N/A
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable. Unless
stated otherwise, the time interval T shall be 30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.
Enclosure_1 Page 8 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
2.7.1 Replace the subclause as follows: Built-in component. N/A
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of 5.3
shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and earth
fault protection may be provided by protective
devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT Built-in component. N/A
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for PLUGGABLE EQUIPMENT TYPE A
the building installation shall be regarded as
providing protection in accordance with the rating of
the wall socket outlet.
2.7.2 This subclause has been declared ‘void’. N/A
3.2.3 Delete the NOTE in Table 3A, and delete also in this N/A
table the conduit sizes in parentheses.
3.2.5.1 Replace “60245 IEC 53” by “H05 RR-F”; N/A
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 | 0,75 a) | Over 6
b)
up to and including 10| (0,75) 1,0 | Over 10 up
to and including 16| (1,0) c) 1,5 |
In the conditions applicable to Table 3B delete the
words “in some countries” in condition a).
In NOTE 1, applicable to Table 3B, delete the
second sentence.
Enclosure_1 Page 9 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)


Clause Requirement + Test Result - Remark Verdict
3.2.5.1 NOTE Z1 The harmonised code designations corresponding to
the IEC cord types are given in Annex ZD
N/A
(A2:2013)
3.3.4 In Table 3D, delete the fourth line: conductor sizes N/A
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A
4.3.13.6 Replace the existing NOTE by the following: N/A
(A1:2010)
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic fields
0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).
Standards taking into account mentioned N/A
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are indicated
in the OJEC.
Annex H Replace the last paragraph of this annex by: N/A
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall not
exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is
taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
Bibliograph Additional EN standards. 
y

ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 


THEIR CORRESPONDING EUROPEAN PUBLICATIONS

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.2.4.1 In Denmark, certain types of Class I appliances (see Built-in component. N/A
3.2.1.1) may be provided with a plug not establishing No power supply cord
earthing conditions when inserted into Danish provided.
socket-outlets.
1.2.13.14 In Norway and Sweden, for requirements see Built-in component. N/A
(A11:2009) 1.7.2.1 and 7.3 of this annex.
Enclosure_1 Page 10 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.5.7.1 In Finland, Norway and Sweden, resistors bridging No such resistor used. N/A
(A11:2009) BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT
TYPE A must comply with the requirements in 1.5.7.1.
In addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.
1.5.8 In Norway, due to the IT power system used (see Built-in component. N/A
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
1.5.9.4 In Finland, Norway and Sweden, the third dashed No such components.. N/A
sentence is applicable only to equipment as defined
in 6.1.2.2 of this annex.
Enclosure_1 Page 11 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.2.1 In Finland, Norway and Sweden, CLASS I Built-in component. N/A
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”

1.7.2.1 In Norway and Sweden, the screen of the cable


(A11:2009)
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in some
circumstances create a fire hazard. Connection to a
cable distribution system has therefore to be
provided through a device providing electrical
isolation below a certain frequency range (galvanic
isolator, see EN 60728-11).”
Enclosure_1 Page 12 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for
1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
1.7.2.1 In Denmark, CLASS I PLUGGABLE EQUIPMENT Built-in component. N/A
(A2:2013)
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
1.7.5 In Denmark, socket-outlets for providing power to No socket-outlet provided. N/A
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when
used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in
accordance with Standard Sheet DK 1-1b or DK 1-
5a.
1.7.5 For CLASS II EQUIPMENT the socket outlet shall be in
(A11:2009)
accordance with Standard Sheet DKA 1-4a.
Enclosure_1 Page 13 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.5 In Denmark, socket-outlets for providing power to No socket-outlet provided. N/A
(A2:2013) other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard Sheets
are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception for
STATIONARY EQUIPMENT where the socket-
outlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class
II apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet
DKA 1-4a. Other current rating socket outlets shall
be in compliance with by DS 60884-2-D1
Standard Sheet DKA 1-3a or DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
2.2.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and Built-in component. N/A
6.1.2.2 of this annex.
2.3.2 In Finland, Norway and Sweden there are No TNV circuits. N/A
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
2.3.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and No TNV circuits. N/A
6.1.2.2 of this annex.
2.6.3.3 In the United Kingdom, the current rating of the Considered. P
circuit shall be taken as 13 A, not 16 A.
2.7.1 In the United Kingdom, to protect against excessive Not direct plug-in. N/A
currents and short-circuits in the PRIMARY CIRCUIT
of DIRECT PLUG-IN EQUIPMENT, tests according
to 5.3 shall be conducted, using an external
protective device rated 30 A or 32 A. If these tests
fail, suitable protective devices shall be included as
integral parts of the DIRECT PLUG-IN EQUIPMENT,
so that the requirements of 5.3 are met.
2.10.5.13 In Finland, Norway and Sweden, there are No TNV circuits. N/A
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
3.2.1.1 In Switzerland, supply cords of equipment having a Built-in component. N/A
RATED CURRENT not exceeding 10 A shall be No power supply cord
provided with a plug complying with SEV 1011 or provided.
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15 3P+N+PE
250/400 V, 10 A
Enclosure_1 Page 14 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
SEV 6533-2.1991 Plug Type 11 L+N
250 V, 10 A
SEV 6534-2.1991 Plug Type 12 L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socket-
outlet system is being introduced in Switzerland, the
plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400
V, 16 A

SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A

SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16


A
3.2.1.1 In Denmark, supply cords of single-phase Built-in component. N/A
equipment having a rated current not exceeding13 A No power supply cord
shall be provided with a plug according to the Heavy provided.
Current Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT exceeding
13 A is provided with a supply cord with a plug, this
plug shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.
Enclosure_1 Page 15 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Denmark, supply cords of single-phase Built-in component. N/A
(A2:2013) equipment having a rated current not exceeding 13
A shall be provided with a plug according to DS No power supply cord
60884-2-D1. provided.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Justification
the Heavy Current Regulations, 6c
3.2.1.1 In Spain, supply cords of single-phase equipment Built-in component. N/A
having a rated current not exceeding 10 A shall be No power supply cord
provided with a plug according to UNE 20315:1994. provided.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules, shall be
provided with a plug in accordance with standard
UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
3.2.1.1 In the United Kingdom, apparatus which is fitted Built-in component. N/A
with a flexible cable or cord and is designed to be No power supply cord
connected to a mains socket conforming to BS 1363 provided.
by means of that flexible cable or cord and plug,
shall be fitted with a ‘standard plug’ in accordance
with Statutory Instrument 1768:1994 - The Plugs and
Sockets etc. (Safety) Regulations 1994, unless
exempted by those regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
Enclosure_1 Page 16 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Ireland, apparatus which is fitted with a flexible Built-in component. N/A
cable or cord and is designed to be connected to a No power supply cord
mains socket conforming to I.S. 411 by means of provided.
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.
3.2.4 In Switzerland, for requirements see 3.2.1.1 of this N/A
annex.
3.2.5.1 In the United Kingdom, a power supply cord with Built-in component. N/A
conductor of 1,25 mm2 is allowed for equipment with No power supply cord
a rated current over 10 A and up to and including 13 provided.
A.
3.3.4 In the United Kingdom, the range of conductor Built-in component. N/A
sizes of flexible cords to be accepted by terminals No power supply cord
for equipment with a RATED CURRENT of over 10 provided.
A up to and including 13 A is:
• 1,25 mm2 to 1,5 mm2 nominal cross-sectional area.
4.3.6 In the United Kingdom, the torque test is performed Not direct plug-in. N/A
using a socket outlet complying with BS 1363 part
1:1995, including Amendment 1:1997 and
Amendment 2:2003 and the plug part of DIRECT
PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test of 12.17
is performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of clauses
22.2 and 23 also apply.
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is known Not direct plug-in. N/A
as plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 - National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets for
domestic use) Regulations, 1997.
Enclosure_1 Page 17 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
5.1.7.1 In Finland, Norway and Sweden TOUCH Built-in component. N/A
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A
that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation
of that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1 In Finland, Norway and Sweden, add the following No TNV circuits. N/A
(A1:2010)
text between the first and second paragraph of the
compliance clause:
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and in
addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
Enclosure_1 Page 18 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).

It is permitted to bridge this insulation with a


capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN
60384-14:2005, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN
60384-14:
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 60384-14, in the
sequence of tests as described in EN 60384-14.
6.1.2.2 In Finland, Norway and Sweden, the exclusions No TNV circuits. N/A
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected PROTECTIVE
EARTHING CONDUCTOR and is provided with
instructions for the installation of that conductor by a
SERVICE PERSON.
7.2 In Finland, Norway and Sweden, for requirements Not connected to cable N/A
see 6.1.2.1 and 6.1.2.2 of this annex. distribution systems.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
7.3 In Norway and Sweden, for requirements see Not connected to cable N/A
(A11:2009)
1.2.13.14 and 1.7.2.1 of this annex. distribution systems.
Enclosure_1 Page 19 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex ZD
(informative)

IEC and CENELEC code designations for flexible cords


Type of flexible cord Code designations
IEC CENELEC
PVC insulated cords
Flat twin tinsel cord 60227 IEC 41 H03VH-Y
Light polyvinyl chloride sheathed flexible cord 60227 IEC 52 H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord 60277 IEC 53 H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord 60245 IEC 51 H03RT-F
Ordinary tough rubber sheathed flexible cord 60245 IEC 53 H05RR-F
Ordinary polychloroprene sheathed flexible cord 60245 IEC 57 H05RN-F
Heavy polychloroprene sheathed flexible cord 60245 IEC 66 H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord 60245 IEC 86 H03RR-H
Rubber insulated, crosslinked PVC sheathed cord 60245 IEC 87 H03RV4-H
Crosslinked PVC insulated and sheathed cord 60245 IEC 88 H03V4V4-H
Enclosure_1 Page 20 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60950-1


(AUSTRALIA/NEW ZEALAND) NATIONAL DIFFERENCES
(Information technology equipment-safety)
Differences according to................ : AS/NZS 60950.1:2015
Attachment Form No. ..................... : AU_NZ_ND_IEC60950_1F
Attachment Originator ................... : JAS-ANZ

Master Attachment ......................... : 2017-06


Copyright © 2017 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

National Differences --
Appendix Variations to IEC 60950-1, Ed 2.2 (2013) for Australia and New Zealand --
ZZ
1.2 DEFINITIONS P
After definition ‘PERSON, SERVICE’, insert the Added. P
following new definition:
POTENTIAL IGNITION SOURCE…….1.2.12.201
1.5 COMPONENTS P
1.5.1 1. ............................................................. First Added and considered. P
paragraph, insert the following text after the
words ‘IEC component standard:
or the relevant Australian/New Zealand
Standard
2........................................................ In the
Note, insert the following text after the word
standard:
or the relevant Australian/New Zealand
Standard
3........................................................ Second
paragraph, delete the words ‘without further
evaluation’
Enclosure_1 Page 21 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

1.5.2 1 ................................................................ First Added and considered. P


paragraph, insert the following text after the
word ‘standard’
or an Australian/New Zealand Standard
2 ................................................................ First
paragraph, second dash item, second line,
insert the following text after the word
‘standard’
or an Australian/New Zealand Standard
3 ................................................................ First
paragraph, second dash item, last line, insert
the following text after the word ‘standard’:
or an Australian/New Zealand Standard
1.7 MARKINGS AND INSTRUCTIONS P
1.7.1.3 Delete existing text and replace with the following: P
Graphical symbols placed on the equipment as a
requirement of this standard, shall be in accordance
with IEC 60417 or ISO 3864-2 or ISO 7000, if
available. In the absence of suitable symbols, the
manufacturer may design specific graphical symbols.
Symbols as required by this standard placed on the
equipment shall be explained in the user manual
2.9 ELECTRICAL INSULATION P
2.9.2 Variation P
Second paragraph, delete the word ‘designated’
3.2.5 POWER SUPPLY CORDS N/A
Table 3B Variation Built-in component. N/A
1. ..................................................... Delete the
first four rows and replace with the following:
Over 0.2 up to and including 3 0.5a 18
[0.8]
Over 3 up to and including 7.5 0.75 16
[1.3]
Over 7.5 up to including 10 (0.75)b 16
1.00 [1.3]
Over 10 up to including 16 (1.0)c 14
1.5 [2]
2. ...........................................................Delete N/A
NOTE 1 and renumber existing NOTE 2 as
‘NOTE’
Enclosure_1 Page 22 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

3. ...........................................................Delete N/A
Footnote a and replace with the following:
a
This nominal cross-sectional area is only allowed for
Class II appliances if the length of the power supply cord,
measured between the point where the cord, or cord
guard, enters the appliance, and the to the plug does
not exceed 2 m (0,5 mm2 three-core supply flexible
cords are not permitted; see AS/NZS 3191)

4.3 DESIGN AND CONSTRUCTION N/A


4.3.6 Variation No direct-plug-in equipment. N/A
Delete the third paragraph and replace with the
following:
Equipment with a plug portion, suitable for insertion N/A
into a 10 A 3-pin flat-pin socket-outlet complying with
AS/NZS 3112 shall comply with the requirements in
AS/NZS 3112 for equipment with integral pins for
insertion into socket-outlets
4.3.8 Addition No batteries. N/A
Eighth paragraph, insert the following new note after
the first dash item:
NOTE 6.201 In cases where the voltage source is N/A
provided by power from an unassociated power
source, consideration should be given to the effects
of possible single fault conditions in the unassociated
equipment. If the power source is unknown then it
should be assumed that the maximum limit of SELV
may be applied to the source input under assumed
single fault conditions in the source when assessing
the charging circuit in the equipment under test.
4.3.13.5.1 Variation No laser. N/A
Delete the first paragraph and replace with the
following:
Except as permitted below, equipment shall be
classified and labelled according to IEC 60825-1 or
AS/NZS 60825.1, IEC 60825-2 or AS/NZS 60825.2
and IEC 60825-12, as applicable
Third paragraph, first sentence, after ‘IEC 60825-1’, N/A
insert the following text: or AS/NZS 60825.1
Fourth paragraph, after ‘IEC 60825-1’, insert the N/A
following text: or AS/NZS 60825.1
4.7 RESISTANCE TO FIRE N/A
4.7 Addition No alternative tests applied. N/A
At the end of Clause 4.7, insert the following text:
For alternate tests refer to Clause 4.7.201
6 CONNECTION TO TELECOMMUNICATIONS NETWORKS N/A
Enclosure_1 Page 23 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

6.2.2 Variation No TNV circuits. N/A


For Australia only, delete the first paragraph and
Note, and replace with the following:
In Australia only, compliance with 6.2.2 shall be
checked by the tests of both 6.2.2.1 and 6.2.2.2
6.2.2.1 Variation No TNV circuits. N/A
For Australia only, delete the first paragraph including
the Notes, and replace with the following:
In Australia only, the electrical separation is subjected
to 10 impulses of alternating polarity, using the
impulse test generator Reference 1 of Table N.1.
The interval between successive impulses is 60 s
and the initial voltage, Uc, is:
(i) ............................................................. for 6.2.1
a): 7.0 kV for hand-held telephones and
for headsets and 2.5 kV for other
equipment; and
(ii) ............................................................ For
6.2.1 b) and 6.2.1 c): 1.5kV
NOTE 201 The 7 kV impulse simulates lightning surges on typical N/A
rural and semi-rural network lines
NOTE 202 The value of 2.5 kV for 6.2.1 a) was chosen to ensure N/A
the adequacy of the insulation concerned and does not necessarily
simulate likely overvoltages

6.2.2.2 Variation No TNV circuits N/A


For Australia only, delete the second paragraph
including the Note, and replace with the following:
In Australia only, the a.c. test voltage is
(i) .........................................................................for
6.2.1 a): 3kV; and
(ii) ........................................................................for
6.2.1b) and 6.2.1c): 1.5kV
NOTE 201 Where there are capacitors across the insulation under N/A
test, it is recommended that d.c. test voltages are used.

NOTE 202 The 3 kV and 1.5 kV values have been determined N/A
considering the low frequency induced voltages from the power
supply distribution system.

7 CONNECTION TO CABLE DISTRIBUTION NETWORK N/A


7.3 Addition N/A
Add the following before the first paragraph:
Equipment providing functions that fall only within the
scope of AS/NZS 60065 and that incorporate a PSTN
interface, are not required to comply with this Clause
where the only ports provided on the equipment, in
addition to a coaxial cable connection and a PSTN
interface, are audio or video ports and analogue or
data ports not intended to be used for
telecommunications purposes
Enclosure_1 Page 24 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Annex P Addition N/A


Add the following Normative References:
AS/NZS 3191, Electric flexible cords
AS/NZS 3112, Approval and test specification—
Plugs and socket-outlets

Special national conditions (if any) --


1.2.12 FLAMMABILITY P
1.2.12.15 Addition Added. P
After Clause 1.2.12.15, insert the following new
clause:
1.2.12.201 POTENTIAL IGNITION SOURCE P
Possible fault which can start a fire if the open-circuit
voltage measured across an interruption or faulty
contact exceeds a value of 50 V (peak) a.c. or d.c.
and the product of the peak value of this voltage and
the measured r.m.s. current under normal operating
conditions exceeds 15 VA
Such a faulty contact or interruption in an electrical P
connection includes those which may occur in
CONDUCTIVE PATTERNS on PRINTED BOARDS
NOTE 1 An electronic protection circuit may be used P
to prevent such a fault from becoming a POTENTIAL
IGNITION SOURCE
NOTE 2 This definition is from AS/NZS 60065:2012, P
Clause 2.8.11.
4 PHYSICAL REQUIREMENTS
4.1 Addition No display devices. N/A
After Clause 4.1, insert new Clause 4.1.201 as
follows:
4.1.201 Display devices used for television purposes N/A
Display devices which may be used for television
purposes, with a mass of 7 kg or more, shall comply
with the requirements for stability and mechanical
hazards, including the additional stability
requirements for television receivers, specified in
AS/NZS 60065
4.3 DESIGN AND CONSTRUCTION N/A
4.3.8 Addition No batteries. N/A
After Clause 4.3.8, add the following new clause as
follows
Enclosure_1 Page 25 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

4.3.8.201 Products containing coin/button cell batteries N/A


and batteries designated R1
The requirements of AS/NZS 60065:2012
Amendment 1:2015, Clause 14.10.201 apply for this
Clause.
4.7 RESISTANCE TO FIRE N/A
4.7.3.6 Addition No high-voltage components. N/A
After Clause 4.7.3.6, add new clauses as follows:
4.7.201 Resistance to fire—Alternative tests N/A
4.7.201.1 General N/A
Parts of non-metallic material shall be resistant to
ignition and spread of fire. This requirement does not
apply to decorative trims, knobs and other parts
unlikely to be ignited or to propagate flames from
inside the apparatus, or the following:
a) Components that are contained in an enclosure
having a flammability category of V-0 according to
AS/NZS 60695.11.10 and having openings only for
the connecting wires filling the openings completely,
and for ventilation not exceeding 1 mm in width
regardless of length.
b) The following parts which would contribute N/A
negligible fuel to a fire:
– small mechanical parts, the mass of which does
not exceed 4 g, such as mounting parts, gears,
cams, belts and bearings;
– small electrical components, such as capacitors
with a volume not exceeding 1,750 mm3, integrated
circuits, transistors and optocoupler packages, if
these components are mounted on material of
flammability category V-1, or better, according to
AS/NZS 60695.11.10
NOTE In considering how to minimize propagation of fire and what N/A
‘small parts are, account should be taken of the cumulative effect
of small parts adjacent to each other for the possible effect of
propagating the fire from one part to another

Compliance shall be checked by the tests of N/A


4.7.201.2, 4.7.201.3, 4.7.201.4 and 4.7.201.5
For the base material of printed boards, compliance N/A
shall be checked by the test of 4.7.201.5
The tests shall be carried out on parts of non-metallic N/A
material which have been removed from the
apparatus. When the glow-wire test is carried out, the
parts shall be placed in the same orientation as they
would be in normal use.
These tests are not carried out on internal wiring
Enclosure_1 Page 26 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

4.7.201.2 Testing of non-metallic materials N/A


Parts of non-metallic material shall be subject to the
glow-wire test of AS/NZS 60695.2.11 which shall be
carried out at 550°C
Parts for which the glow-wire test cannot be carried
out, such as those made of soft or foamy material,
shall meet the requirements specified in ISO 9772 for
category FH-3 material. The glow-wire test shall be
not carried out on parts of material classified at least
FH-3 according to ISO 9772 provided that the sample
tested was not thicker than the relevant part.
4.7.201.3 Testing of insulating materials N/A
Parts of insulating material supporting POTENTIAL
IGNITION SOURCES shall be subject to the glow-
wire test of AS/NZS 60695.2.11 which shall be
carried out at 750°C.
The test shall be also carried out on other parts of
insulating material which are
within a distance of 3 mm of the connection.

NOTE Contacts in components such as switch contacts are


considered to be connections.

For parts which withstand the glow-wire test but


produce a flame, other parts above the connection
within the envelope of a vertical cylinder having a
diameter of 20 mm and a height of 50 mm shall be
subjected to the needle-flame test. However, parts
shielded by a barrier which meets the needle-flame
test shall not be tested.
The needle-flame test shall be made in accordance
with AS/NZS 60695.11.5 with the following
modifications:
Enclosure_1 Page 27 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

Clause of AS/NZS Change


60695.11.5
9 Test procedure
9.2 Application of Delete the first and
Needle-flame second paragraphs and
replace with the
following:
The specimen shall be
arranged so that
the flame can be
applied to a vertical or
horizontal edge as
shown in the examples
of Figure 1. If possible
the flame shall be
applied at least 10 mm
from a corner.
The duration of
application of the test
flame shall be 30 s ± 1
s
9.3 Number of test Delete existing text and
specimens replace with the
following:
The test shall be made
on one specimen. If the
specimen does not
withstand the
test, the test may be
repeated on two
further specimens, both
of which shall
withstand the test.
11 Evaluation of Delete existing text and
test results replace with the
following:
The duration of burning
(tb) shall not exceed 30
s. However, for printed
circuit boards, it shall
not exceed 15s
The needle-flame test shall not be carried out on N/A
parts of material classified as V-0 or V-1 according to
AS/NZS 60695.11.10, provided that the sample
tested was not thicker than the relevant part
Enclosure_1 Page 28 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

4.7.201.4 Testing in the event of non-extinguishing material N/A


If parts, other than enclosures, do not withstand the
glow wire tests of 4.7.201.3 by failure to extinguish
within 30 s after the removal of the glow-wire tip, the
needle-flame test detailed in 4.7.201.3 shall be made
on all parts of non-metallic
material which are within a distance of 50 mm or
which are likely to be impinged upon by flame during
the tests of 4.7.201.3. Parts shielded by a separate
barrier which meets the needle-flame test need not
be tested.
NOTE 1 If the enclosure does not withstand the glow-wire test the N/A
equipment is considered to have failed to meet the requirements of
Clause 4.7.201 without the need for consequential testing.
NOTE 2 If other parts do not withstand the glow-wire test due to N/A
ignition of the tissue paper and if this indicates that burning or
glowing particles can fall onto an external surface underneath the
equipment, the equipment is considered to have failed to meet the
requirements of Clause 4.7.201 without the need for consequential
testing
NOTE 3 Parts likely to be impinged upon by the flame are N/A
considered to be those within the envelope of a vertical cylinder
having a radius of 10 mm and a height equal to the height of the
flame, positioned above the point of the material supporting, in
contact with, or in close proximity to, connections.

4.7.201.5 Testing of printed boards N/A


The base material of printed boards shall be
subjected to the needle-flame test of Clause
4.7.201.3. The flame shall be applied to the edge of
the board where the heat sink effect is lowest when
the board is positioned as in normal use. The
flame shall not be applied to an edge, consisting of
broken perforations, unless the edge is less than 3
mm from a POTENTIAL IGNITION SOURCE.
Enclosure_1 Page 29 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

The test is not carried out if the N/A


– Printed board does not carry any POTENTIAL
IGNITION SOURCE;

– Base material of printed boards, on which the


available apparent power at a connection exceeds 15
VA operating at a voltage exceeding 50 V and equal
or less than 400 V (peak) a.c. or d.c. under normal
operating conditions, is of flammability category V-1
or better according to AS/NZS 60695.11.10, or the
printed boards are protected by an enclosure
meeting the flammability category V-0 according to
AS/NZS 60695.11.10, or made of metal, having
openings only for connecting wires which fill the
openings completely; or

– Base material of printed boards, on which the


available apparatus power at a connection exceeds
15 VA operating at a voltage exceeding 400 V (peak)
a.c. or d.c. under normal operating conditions, and
base material of printed boards supporting spark
gaps which provides protection against overvoltages,
is of flammability category V-0 according to AS/NZS
60695.11.10 or the printed boards are contained in a
metal enclosure, having openings only for connecting
wires which fill the openings completely
.
Compliance shall be determined using the smallest
thickness of the material.

NOTE Available apparent power is the maximum apparent power N/A


which can be drawn from the supplying circuit through a resistive
load whose value is chosen to maximise the
apparent power for more than 2 m when the circuit supplied is
disconnected.
Enclosure_1 Page 30 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60950-1 with A1:2009 and A2:2013


CANADA NATIONAL DIFFERENCES
Information technology equipment – Safety – Part 1: General requirements
Differences according to ............... : CAN/CSA-C22.2 No. 60950-1-07, Amd 1:2011, Amd 2:2014
Attachment Form No. .................... : CA_ND_IEC60950_1F
Attachment Originator ................... : CSA
Master Attachment......................... : Date (2015-05)
Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

1.1.1 All equipment is to be designed to allow installation Considered. P


in accordance with the National Electrical Code
(NEC), ANSI/NFPA 70, the Canadian Electrical
Code (CEC), Part I, CAN/CSA C22.1, and when
applicable, the National Electrical Safety Code,
IEEE C2. Also, unless marked or otherwise
identified, installation is allowed per the Standard
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.
1.1.2 Baby monitors are required to additionally comply No such equipment. N/A
with ASTM F2951, Consumer Safety Specification
for Baby Monitors.
1.4.14 For Pluggable Equipment Type A, the protection in 50A considered. P
the installation is assumed to be 20A:
1.5.5 For lengths exceeding 3.05 m, external No interconnecting cable N/A
interconnecting flexible cord and cable assemblies provided.
are required to be a suitable cable type (e.g., DP,
CL2) specified in the CEC/NEC.
For lengths 3.05 m or less, external interconnecting
flexible cord and cable assemblies that are not
types specified in the CEC/NEC are required to
have special construction features and identification
markings.
1.7.1 Equipment for use on a.c. mains supply systems Built-in component. N/A
with a neutral and more than one phase conductor
(e.g. 120/240 V, 3-wire) require a special marking
format for electrical ratings.
A voltage rating that exceeds an attachment plug
cap rating is only permitted if it does not exceed the
extreme operating conditions in Table 2 of
CAN/CSA C22.2 No. 235, and if it is part of a range
that extends into the Table 2 "Normal Operating
Conditions." Likewise, a voltage rating shall not be
lower than the specified "Normal Operating
Conditions," unless it is part of a range that extends
into the "Normal Operating Conditions."
Enclosure_1 Page 31 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

1.7.7 Wiring terminals intended to supply Class 2 outputs No such terminals. N/A
in accordance with CEC Part 1 or NEC shall be
marked with the voltage rating and “Class 2” or
equivalent. Marking shall be located adjacent to the
terminals and shall be visible during wiring.
2.5 Where a fuse is used to provide Class 2, Limited No limited power source. N/A
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
2.6 Equipment with isolated ground (earthing) N/A
receptacles are required to comply with NEC
250.146(D) and CEC 10-112 and 10-906(8).
2.7.1 Suitable NEC/CEC branch circuit protection rated at Built-in component. N/A
the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.

Power distribution transformers distributing power


at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent protection.
3.2 Wiring methods (terminals, leads, etc.) used for the Built-in component. N/A
connection of the equipment to the mains shall be
in accordance with the NEC/CEC.
3.2.1 Power supply cords are required to have Built-in component. N/A
attachment plugs rated not less than 125 percent of No power supply cord
the rated current of the equipment. provided.
3.2.1.2 Equipment connected to a centralized d.c. power No such equipment. N/A
system, and having one pole of the DC mains input
terminal connected to the main protective earthing
terminal in the equipment, is required to comply
with special earthing, wiring, marking and
installation instruction requirements.
3.2.3 Permanent connection of equipment to the mains Built-in component. N/A
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
3.2.5 Power supply cords are required to be no longer Built-in component. N/A
than 4.5 m in length. No power supply cord
provided.
Minimum cord length is required to be 1.5 m, with
certain constructions such as external power
supplies allowed to consider both input and output
cord lengths into the requirement.

Flexible power supply cords are required to be


compatible with Article 400 of the NEC, and Tables
11 and 12 of the CEC.
Enclosure_1 Page 32 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

3.2.9 Permanently connected equipment is required to Built-in component. N/A


have a suitable wiring compartment and wire Not permanently connected
bending space. equipment.
3.3 Wiring terminals and associated spacings for field No field wiring terminals. N/A
wiring connections shall comply with CSA C22.2
No. 0
3.3.3 Wire binding screws are not permitted to attach N/A
conductors larger than 10 AWG (5.3 mm2).
3.3.4 Terminals for permanent wiring, including protective N/A
earthing terminals, are required to be suitable for
US/Canadian wire gauge sizes, rated 125 percent
of the equipment rating, and be specially marked
when specified (1.7.7).
3.3.5 First column of Table 3E revised to require “Smaller Built-in component. N/A
of the RATED CURRENT of the equipment or the
PROTECTIVE CURRENT RATING of the circuit
under consideration.”
3.4.2 Motor control devices are required for No such equipment. N/A
cord-connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V, or
is rated more than 1/3 hp (locked rotor current over
43 A).
3.4.8 Vertically-mounted disconnect switches and circuit Built-in component. N/A
breakers are required to have the "on" position No such device used.
indicated by the handle in the up position.
3.4.11 For computer room applications, equipment with Built-in component. N/A
battery systems capable of supplying 750 VA for No such equipment.
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
4.3.12 The maximum quantity of flammable liquid stored in No flammable liquid used. N/A
equipment is required to comply with NFPA 30.
4.3.13.5. Equipment with lasers is required to meet the U.S. No laser source provided. N/A
1 Code of Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
4.7 For computer room applications, automated Built-in component. N/A
information storage systems with combustible No such equipment.
media greater than 0.76 m3 (27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Enclosure_1 Page 33 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

4.7.3.1 For computer room applications, enclosures with Built-in component. N/A
combustible material measuring greater than 0.9 No such equipment.
m2 (10 sq ft) or a single dimension greater than 1.8
m (6 ft) are required to have a flame spread rating
of 50 or less. For other applications, enclosures
with the same dimensions require a flame spread
rating of 200 or less.
Non-metallic enclosures of equipment for use in N/A
spaces used for environmental air (plenums) are
required to comply
with UL 2043.
Annex H Equipment that produces ionizing radiation is No ionizing radiation. N/A
required to comply with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
Enclosure_1 Page 34 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

OTHER DIFFERENCES

The following key national differences are based on requirements other than national regulatory
requirements.
1.5.1 Some components and materials associated with Considered. P
the risk of fire, electric shock, or personal injury are
required to have component or material ratings in
accordance with the applicable national (Canadian
and/or U.S.) component or material standard
requirements. These components include:
attachment plugs, battery packs (rechargeable type,
used with transportable equipment), cathode ray
tubes, circuit breakers, communication circuit
accessories, connectors (used for current
interruption of non-LPS circuits), cord sets and
power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), fuseholders, ground-fault
current interrupters, industrial control equipment,
insulating tape, interconnecting cables,
lampholders, limit controls, printed wiring, protectors
for communications circuits, receptacles, solid state
controls, supplementary protectors, switches
(including interlock switches), thermal cutoffs,
thermostats, (multi-layer) transformer winding wire,
transient voltage surge suppressors, tubing, wire
connectors, and wire and cables.
1.6.1.2 A circuit for connection to the DC Mains Supply is No DC Mains Supply N/A
classified as either a SELV Circuit, TNV-2 Circuit or connections.
Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage shall include
consideration of the battery charging “float voltage”
associated with the intended supply system,
regardless of the marked power rating of the
equipment.
2.3.1 For TNV-2 and TNV-3 circuits with other than No TNV circuits. N/A
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the maximum acceptable current
through a 2000 ohm resistor (or greater) connected
across the voltage source with other loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal operating conditions.
2.3.2.1 In the event of a single fault between TNV and N/A
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
2.6.2 Equipment with functional earthing is required to be No functional earthing symbol N/A
marked with the functional earthing symbol (IEC used.
60417-6092).
Enclosure_1 Page 35 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

2.6.3.4 Protective bonding conductors of non-standard Built-in component. N/A


protective bonding constructions (e.g., printed No such construction.
circuit traces) may be subjected to the additional
limited short circuit test conditions specified.
4.2.8.1 Enclosures around CRTs with a face diameter of No CRT provided. N/A
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
4.3.2 Equipment with handles is required to comply with No handle provided. N/A
special loading tests.
4.3.8 Battery packs for both portable and stationary No battery pack used. N/A
applications are required to comply with special
component requirements.
5.1.8.3 Equipment intended to receive telecommunication No such equipment. N/A
ringing signals is required to comply with a special
touch current measurement tests.
5.3.7 Internal (e.g., card cage) SELV circuit connectors Considered did not occur. N/A
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
During abnormal operating testing, if a circuit is
interrupted by the opening of a component, the test
shall be repeated twice (three tests total) using new
components as necessary.
6.4 Equipment intended for connection to No TNV circuit. N/A
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
Annex UL articulated accessibility probe (Fig EE.3) Not a shredder. N/A
EE required for assessing accessibility to
document/media shredders instead of the Figure 2A
test finger.
M.2 Continuous ringing signals up to 16 mA only are No such equipment. N/A
permitted if the equipment is subjected to special
installation and performance restrictions.
Annex Equipment connected to a telecommunication and Unit is not connected to a N/A
NAD cable distribution networks and supplied with an telecommunication and cable
earphone intended to be held against, or in the ear distribution networks.
is required to comply with special acoustic pressure
requirements.
Enclosure_1 Page 36 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60950-1 with A1: 2009 and A2:2013
U.S.A. NATIONAL DIFFERENCES
Information technology equipment – Safety – Part 1: General requirements
Differences according to ................ : UL 60950-1-07(Second Edition) + A1: 2011 + A2: 2014
Attachment Form No. ...................... : US_ND_IEC60950_1F
Attachment Originator .................... : UL
Master Attachment .......................... : Date 2014-07
Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

Special national conditions --

1.1.1 All equipment is designed as to allow installation in Considered. P


accordance with the National Electrical Code (NEC),
ANSI/NFPA 70, Canadian Electrical Code (CEC), Part
I, CAN/CSA C22.1, and if applicable, the National
Electrical Safety Code, IEEE C2
Also, unless marked or otherwise identified, P
installation is allowed per the Standard for the
Protection of Electronic Computer/Data-Processing
Equipment, ANSI/NFPA 75
1.1.2 Baby monitors are required to additionally comply No such equipment. N/A
with ASTM F2951, Consumer Safety Specification for
Baby Monitors
1.4.14 For Pluggable Equipment Type A, the protection in the 50A considered. P
installation is assumed to be 20A
1.5.5 For lengths exceeding 3.05 m, external No interconnecting cable N/A
interconnecting flexible cord and cable assemblies are provided.
required to be a suitable cable type (e.g., DP, CL2)
specified in the /NEC
For lengths 3.05 m or less, external interconnecting N/A
flexible cord and cable assemblies that are not types
specified in the NEC are required to have special
construction features and identification markings
1.7.1 Equipment for use on a.c. mains supply systems with Built-in component. N/A
a neutral and more than one phase conductor (e.g.
120/240 V, 3-wire) require a special marking format for
electrical ratings
A voltage rating that exceeds an attachment plug cap N/A
rating is only permitted if it does not exceed the
extreme operating conditions in Table 2 of CAN/CSA
C22.2 No. 235, and
- if it is part of a range that extends into the Table 2 N/A
"Normal Operating Conditions"
Likewise, a voltage rating is not to be lower than the N/A
specified "Normal Operating Conditions," unless it is
part of a range that extends into the "Normal
Operating Conditions"
1.7.7 Wiring terminals intended to supply Class 2 outputs in No such terminals. N/A
accordance with NEC or CEC Part 1 or NEC are
marked with the voltage rating and “Class 2” or
equivalent
Enclosure_1 Page 37 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

- Marking is located adjacent to the terminals N/A


- Marking is visible during wiring N/A
2.5 Fuse providing Class 2, Limited Power Source, or No limited power source. N/A
TNV current limiting is not operator-accessible unless
it is not interchangeable
2.6 Equipment with isolated ground (earthing) receptacles N/A
is in compliance with NEC 250.146(D) and CEC 10-
112 and 10-906(8)
2.7.1 Suitable NEC/CEC branch circuit protection rated at Built-in component. N/A
the maximum circuit rating is provided for all standard
supply outlets and receptacles (such as supplied in
power distribution units) if the supply branch circuit
protection is not suitable.
Power distribution transformers distributing power at N/A
100 volts or more, and rated 10 kVA or more, provided
with special transformer overcurrent protection
3.2 Wiring methods (terminals, leads, etc.) used for the Built-in component. N/A
connection of the equipment to the mains is in
accordance with the NEC/CEC
3.2.1 Attachment plugs of power supply cords are rated not Built-in component. N/A
less than 125 percent of the rated current of the No power supply cord
equipment provided.
3.2.1.2 Equipment connected to a centralized d.c. power No such equipment. N/A
system, and having one pole of the DC mains input
terminal connected to the main protective earthing
terminal in the equipment comply with special
earthing, wiring, marking and installation instruction
requirements
3.2.3 Permanent connection of equipment to the mains Built-in component. N/A
supply by a power supply cord is not permitted, except
for certain equipment, such as ATMs
3.2.5 Power supply cords are no longer than 4.5 m in length Built-in component. N/A
No power supply cord
provided.
Minimum cord length is 1.5 m, with certain N/A
constructions such as external power supplies allowed
to consider both input and output cord lengths into the
requirement
Flexible power supply cords are compatible with N/A
Article 400 of the NEC, and Tables 11 and 12 of the
CEC
3.2.9 Permanently connected equipment has a suitable Built-in component. N/A
wiring compartment and wire bending space
Not permanently connected
equipment.
3.3 Wiring terminals and associated spacings for field No field wiring terminals. N/A
wiring connections comply with CSA C22.2 No. 0
3.3.3 Wire binding screws are not attached with conductors N/A
larger than 10 AWG (5.3 mm2)
3.3.4 Terminals for permanent wiring, including protective N/A
earthing terminals, are suitable for Canadian/US wire
gauge sizes, are
Enclosure_1 Page 38 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

- rated 125 per cent of the equipment rating, and N/A


- are specially marked when specified (1.7.7) N/A
3.3.5 Revise first column of Table 3E to “Smaller of the Built-in component. N/A
RATED CURRENT of the equipment or the PROTECTIVE
CURRENT RATING of the circuit under consideration”
3.4.2 Motor control devices are provided for cord-connected No such equipment. N/A
equipment with a motor if the equipment is rated more
than 12 A,
- or if the motor has a nominal voltage rating greater N/A
than 120 V
- or is rated more than 1/3 hp (locked rotor current N/A
over 43 A)
3.4.8 Vertically-mounted disconnect switches and circuit Built-in component. N/A
breakers have the "on" position indicated by the
No such device used.
handle in the up position
3.4.11 For computer room applications, equipment with Built-in component. N/A
battery systems capable of supplying 750 VA for five
No such equipment.
minutes have a battery disconnect means that may be
connected to the computer room remote power-off
circuit
4.3.12 The maximum quantity of flammable liquid stored in No flammable liquid used. N/A
equipment complies with NFPA 30
4.3.13.5.1 Equipment with lasers meets the U.S. Code of No laser source provided. N/A
Federal Regulations 21 CFR 1040 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
4.7 For computer room applications, automated Built-in component. N/A
information storage systems with combustible media No such equipment.
greater than 0.76 m3 (27 cu ft) have a provision for
connection of either automatic sprinklers or a gaseous
agent extinguishing system with an extended
discharge
4.7.3.1 For computer room applications, enclosures with Built-in component. N/A
combustible material measuring greater than 0.9m2
No such equipment.
(10 sq ft) or a single dimension greater than 1.8 m (6
ft) have a flame spread rating of 50 or less
For other applications, enclosures with the same N/A
dimensions require a flame spread rating of 200 or
less
4.7.3.1 Non-metallic enclosures of equipment for use in Built-in component. N/A
spaces used for environmental air (plenums) are
No such equipment.
required to comply with UL 2043
Annex H Equipment that produces ionizing radiation complies No ionising radiation. N/A
with U.S. Code of Federal Regulations, 21 CFR 1020
(and the Canadian Radiation Emitting Devices Act,
REDR C1370)
Other National Differences --
Enclosure_1 Page 39 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

1.5.1 Some components and materials associated with the Considered. P


risk of fire, electric shock, or personal injury have
component or material ratings in accordance with the
applicable national (Canadian and/or U.S.) component
or material standard requirements.
These components include:
attachment plugs, battery backup systems, battery
packs, cathode ray tubes, circuit breakers,
communication circuit accessories, connectors (used
for current interruption of non-LPS circuits), cord sets
and power supply cords, direct plug-in equipment,
electrochemical capacitor modules (energy storage
modules with ultracapacitors), enclosures (outdoor),
flexible cords and cables, fuses (branch circuit),
fuseholders, ground-fault current interrupters, industrial
control equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits, receptacles,
solid state controls, supplementary protectors, switches
(including interlock switches), thermal cut-offs,
thermostats, (multi-layer) transformer winding wire,
surge protective devices, tubing, vehicle battery
adapters, wire connectors, and wire and cables
1.6.1.2 A circuit for connection to the DC Mains Supply is No DC Mains Supply N/A
classified as a SELV Circuit, TNV-2 Circuit or connections.
Hazardous Voltage Circuit depending on the maximum
operating voltage of the supply
This maximum operating voltage includes N/A
consideration of the battery charging “float voltage”
associated with the intended supply system, regardless
of the marked power rating of the equipment
2.3.1 For TNV-2 and TNV-3 circuits with other than ringing No TNV circuits. N/A
signals and with voltages exceeding 42.4 Vpeak or 60
Vd.c., the maximum acceptable current through a 2000
ohm resistor (or greater) connected across the voltage
source with other loads disconnected is 7.1 mA peak
or 30 mA d.c. under normal operating conditions
2.3.2.1 In the event of a single fault between TNV and SELV N/A
circuits, the limits of 2.2.3 apply to SELV Circuits and
accessible conductive parts
2.6.2 Equipment with functional earthing marked with the No functional earthing symbol N/A
functional earthing symbol (IEC 60417-6092) used.
2.6.3.4 Protective bonding conductors of non-standard Built-in component. N/A
protective bonding constructions (e.g., printed circuit No such construction.
traces) may be subjected to the additional limited short
circuit test conditions specified
4.2.8.1 Enclosures around CRTs with a face diameter of 160 No CRT provided. N/A
mm or more reduce the risk of injury due to the
implosion of the CRT
4.3.2 Equipment with handles complies with special loading No handle provided. N/A
tests
4.3.8 Battery packs for both portable and stationary No battery pack used. N/A
applications comply with special component
requirements
Enclosure_1 Page 40 of 56 Report No. 4788327671

IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict

5.1.8.3 Equipment intended to receive telecommunication No such equipment. N/A


ringing signals comply with a special touch current
measurement tests
5.3.7 Internal (e.g., card cage) SELV circuit connectors and N/A
printed wiring board connectors that are accessible to
the operator and that deliver power are overloaded
During abnormal operating testing, if a circuit is Considered, did not occur. N/A
interrupted by the opening of a component, the test is
repeated twice (three tests total) using new
components as necessary
6.4 Equipment intended for connection to No TNV circuit. N/A
telecommunication network outside plant cable is
protected against overvoltage from power line crosses
in accordance with 6.4 and Annex NAC
Annex EE Articulated accessibility probe (Fig EE.3) is used for Not a shredder. N/A
assessing accessibility to document/media shredders
instead of the Figure 2A test finger
Annex Continuous ringing signals up to 16 mA only are No such equipment. N/A
M.2 permitted if the equipment is subjected to special
installation and performance restrictions
Annex Equipment connected to a telecommunication and Unit is not connected to a N/A
NAD cable distribution networks and supplied with an telecommunication and cable
earphone intended to be held against, or in the ear distribution networks.
comply with special acoustic pressure requirements
Enclosure_1 Page 41 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT


IEC 60950-1 with A1: 2009 and A2:2013
JAPAN NATIONAL DIFFERENCES
Information technology equipment – Safety – Part 1: General requirements

Differences according to ............... : J60950-1 (H29)

Attachment Form No...................... : JP_ND_IEC60950_1F

Attachment Originator ................... : JQA

Master Attachment ......................... : 2017-11

Copyright © 2017 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

National Differences
1.2.4.1 Add the following new notes. No power cords N/A
provided.
Note: Even if the equipment is designed as Class I, the
equipment is regarded as CLASS 0I EQUIPMENT (see
1.2.4.3A) when 2-pin adaptor with earthing lead wire or cord
set having 2-pin plug with earthing lead wire is provided or
recommended.
1.2.4.3A Add the following new clause. Built-in component. N/A

1.2.4.3A CLASS 0I EQUIPMENT


Equipment having attachment plug without earthing blade,
where protection against electric shock is achieved by:
- using BASIC INSULATION, and
- providing either of the following a) or b) in order to connect
those conductive parts that might assume a HAZARDOUS
VOLTAGES in the event of BASIC INSULATION fault to
the PROTECTIVE EARTHING CONDUCTOR in the
building wiring.
a) Provision of 2-pin plug with earthing lead including the
condition of that 2-pin adaptor with earthing lead wire is
provided or recommended.
b) Provision of an independent earthing terminal, when 2-
core mains cord (without earthing conductor) is used.
Note – CLASS 0I EQUIPMENT may have a part constructed
with Double Insulation or Reinforced Insulation.
Enclosure_1 Page 42 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

1.3.2 Add the following notes after the first paragraph: Built-in component. N/A

Note 1 Transportable or similar equipment that are relocated


frequently for intended usage should not be designed as Class
I or CLASS 0I EQUIPMENT unless it is intended to be installed
by service personnel.

Note 2 Considering wiring circumstance in Japan, equipment


intended to be installed where the provision for earthing
connection is unlikely should not be designed as Class I or
CLASS 0I EQUIPMENT unless it is intended to be installed by
service personnel.
1.5.1 Replace the first paragraph with the follows: Considered. P

Where safety is involved, components shall comply either with


the requirements of this standard, with the safety aspects of
the relevant JIS component standard, or IEC component
standards, or components shall have equivalent to or better
properties than these.

Replace Note 1 with the following:

Note 1 Components complying with the interpretation of


Ministerial Ordinance on stipulating technical requirements for
the Electrical Appliance is regarded to have equivalent to or
better performance.

Note 2 JIS or an IEC component standard is considered


relevant only if the component in question clearly falls within its
scope.

Add the following after the last paragraph:

For an appliance connector that is able to fit with appliance


inlet compatible with the standard sheet of IEC 60320-1 or JIS
C 8283-1, the size of the connector shall comply with relevant
standard sheet of IEC 60320-1 or JIS C 8283-1. A power
supply cord set complying with JIS C 8286 is regarded to
comply with this requirement.
Note 3 A power supply cord set provided with appliance
connector that is able to fit with appliance inlet compatible with
the standard sheet of IEC 60320-1 or JIS C 8283-1 should
comply with JIS C 8286.
Enclosure_1 Page 43 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

1.5.2 Add the following Note 2 after the 4th dashed paragraph: No such appliance N/A
coupler.
Note 2 See 1.7.5A when Type C.14 appliance coupler rated
10 A per JIS C 8283-1 is used with an equipment rated not
more than 125 V and rated more than 10 A.
1.5.5 Add the following Note after the last paragraph: No interconnection
cord set.
NOTE An interconnection cord sets provided with
interconnecting coupler for mains supply complying with JIS C
8283-2-2 should comply with JIS C 8286.
1.5.9.1 Add the following in the last of NOTE 1. No such VDR. N/A

Gas discharge tube connected in series with VDR may be


used.
1.7 Replace EE.2 and EE.4 with the following: Built-in component. N/A

JA.1 Shredder warning


JA.3 Shredder power disconnection

1.7.1.2 Replace first and second dashed paragraphs with the Considered. P
followings:

- manufacturer’s or responsible company’s name or trade-mark


or identification mark;

- manufacturer's or responsible company’s model identification


or type reference;
1.7.2.1 Add the following after the second paragraph. Considered. P

Instruction or equipment marking regarding safety shall be


written in Japanese unless otherwise permitted in this
standard.
1.7.2.5 Replace the last sentence with the following: N/A

An acceptable marking for an electric shock hazard is


(6.2.4 of JIS S 0101).
1.7.5 Replace the second paragraph with the following. No socket-outlets N/A
provided.
Socket-outlets conforming to JISC8282-1 are examples of
standard power supply outlets.
Enclosure_1 Page 44 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

1.7.5A Add the following new clause after 1.7.5. No appliance N/A
coupler.
1.7.5A Power supply cord set
If appliance coupler according to IEC60320-1, C.14(rated
current: 10A) is used in equipment whose rated voltage is less
than 125V and rated current is over 10A, the following
instruction or equivalent shall be described in the operating
instruction.
“ Use only designated cord set attached in this equipment”

Example in Japanese:

If appliance coupler is used for connection to the mains and if


the cord set is not provided within the package for the
equipment, suitable information regarding to the cord set shall
be described in the operating instruction

Note Since the combination of appliance inlet with


earthing pin and two-core cord set (without earthing
conductor) is special, the cord set should be attached in the
equipment and the operating instruction should provide the
information that the cord set is exclusively used with the
equipment and not allowed to use with other equipment.
Enclosure_1 Page 45 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

1.7.14A Add the following new clause after 1.7.14. Built-in component. N/A

1.7.14A Marking for CLASS 0I EQUIPMENT


For CLASS 0I EQUIPMENT, the following or equivalent
instructions shall be marked.

- the following instruction shall be marked on the mains plug or


on the visible place of the main body

“Provide an earthing connection”

Example in Japanese:

- the following instruction shall be marked on the visible place


of the main body or written in the operating instructions:

“Provide an earthing connection before the mains plug is


connected to the mains. And, when disconnecting the earthing
connection, be sure to disconnect after pulling out the mains
plug from the mains.”

Example in Japanese:

1.7.14B Add the following new clause after 1.7.14A Built-in component. N/A

1.7.14B Protective earthing conductor used for CLASS 0I


EQUIPMENT

For CLASS 0I EQUIPMENT provided with independent main


protective earthing terminal, where the cord for the protective
earthing connection is not provided within the package for the
equipment, the suitable information for the protective earthing
connection shall be provided in the operating instruction. (See
2.6.3.2)
Enclosure_1 Page 46 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

2.1.1.1 Replace item b) of 2.1.1.1with the following. Built-in component. N/A

b) A test with the test finger, Figure 2A, which shall not contact
parts described above when applied to openings in the
ENCLOSURES after removal of parts that can be detached by
an OPERATOR, including fuseholders, and with OPERATOR
access doors and covers open. It is permitted to leave lamps in
place for this test. Connectors that can be separated by an
OPERATOR, other than those complying with JIS C 8303 or
JIS C 8285 or IEC 60309 series or JIS C 8283 series or IEC
60320 series, shall also be tested during disconnection. But
even if the connector does not comply with these standards,
the one having equivalent to or better performance need not be
tested during disconnection.

Note 4 Connectors complying with Appendix 4 of the


interpretation of Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance is regarded to have
equivalent to or better performance.

2.5 Replace “IEC 60730-1” with “JIS C 9730-1” (in item b)). Considered. P
2.6.2 Delete the following line. Built-in component. N/A

• the symbol ,IEC 60417-5018 (2011-07);


2.6.3.2 Add the following after the first paragraph. No power cords N/A
provided.
However where the single core conductor is used for protective
earthing lead or earthing cord for CLASS 0I EQUIPMENT,
either of the following condition shall be met.

- Use of annealed copper wire with 1.6 mm diameter or


corrosion-inhibiting metal wire having equivalent to or more
strength and thickness.
- Single core cord or single core cab tire cable with 1.25 mm2
or more cross-sectional area
2.6.3.5 Add the following after the first paragraph. No such conductors. N/A

However this requirement does not apply to internal conductor


of the cord set that is covered by the sheath of mains cord and
is formed together with mains plug and appliance connector.
Enclosure_1 Page 47 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

2.6.4.2 Replace the first paragraph with the following. Built-in component. N/A

Equipment required to have protective earthing shall have a


main protective earthing terminal.
For equipment with a DETACHABLE POWER SUPPLY
CORD, the earthing terminal in the appliance inlet is regarded
as the main protective earthing terminal. However, for CLASS
0I EQUIPMENT provided with the separate main protective
earthing terminal other than appliance inlet, the separate main
protective earthing terminal may be treated as mains protective
earthing terminal.

2.6.5.4 Replace the first sentence with the following. Built-in component. N/A

Protective earthing connections of CLASS I EQUIPMENT


shall make earlier and break later than the supply
connections in each of the following:

Add the following after last paragraph:

Note For CLASS 0I EQUIPMENT,1.7.14A is applied


instead of this requirement.
2.6.5.8A Add the following new clause after 2.6.5.8 Built-in component. N/A

2.6.5.8A Earthing of CLASS 0I EQUIPMENT


Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire shall not
be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an earthing
terminal or lead wire for earthing in the external location where
easily visible.
2.7.6 Replace “ISO 3864, No. 5036” with “6.2.4 of JIS S 0101”. N/A
2.10.3.1 Replace the 8th paragraph with the following N/A

The above minimum CLEARANCE for connectors do not apply


to connectors that comply with JIS C 8285, IEC60309 series of
standards, JIS C 8283 series of standards, IEC60320 series of
standards, JIS C 8303, or even if it does not comply with the
above standards but the one having equivalent to or better
performance and dimension which comply with JIS C 8283
series of standards, JIS C 8303 or IEC 60309-2.
Note Connectors complying with Appendix 4 of the
interpretation of Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance is regarded to have
equivalent to or better performance.
Enclosure_1 Page 48 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

2.10.3.2 In Japan, the value of the main power supply transient voltage
Table 2J for the nominal ac main power supply voltage of 100 V is
determined by applying the row of AC main power supply
voltage 150 V.
2.10.4.3 Replace the 6th paragraph with the following N/A

The above minimum CREEPAGE DISTANCE for connectors


do not apply to connectors that comply with JIS C 8285,
IEC60309 series of standards, JIS C 8283 series of standards,
IEC60320 series of standards, JIS C 8303, or even if it does
not comply with the above standards but the one having
equivalent to or better performance and dimension which
comply with JIS C 8283 series of standards, JIS C 8303 or IEC
60309-2.
Note Connectors complying with Appendix 4 of the
interpretation of Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance is regarded to have
equivalent to or better performance.
2.10.9 Replace “1.4.5” in the third paragraph with “1.4.12”. N/A
3.2.3 Add the following after the third paragraph. No power cords N/A
provided.
Table 3A applies when cables complying JIS C 3662 series of
standards or JIS C 3663 series of standards are used. In case
of other cables, cable entries shall be so designed that the
cable could be fitted in a conduit.
3.2.4 Add the following as 4th dashed paragraph. No appliance inlet N/A
- be so constructed that mechanical stress shall not transmit to provided.
the soldering part of inlet terminal during insertion or removal
of the connector except that the body of the inlet is secured
and is secured not only soldering.
Enclosure_1 Page 49 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

3.2.5.1 Add the following after Note 3: No power cords N/A


Note 4 In Japan, mains cords having equivalent to or better provided.
electro-mechanical and fire
safety performance as above and complying with Appendix 1
of the interpretation of Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance can be
used.

Replace the paragraph after Note 3 with the following.

For equipment required to have protective earthing, a


PROTECTIVE EARTHING CONDUCTOR shall be included in
the MAINS SUPPLY cord except for CLASS 0I EQUIPMENT
having separate protective earthing conductor from mains
cord.

Add the following after the second paragraph after Note 3:

Note 5 For the cross-sectional area of mains cord described in


Note 4, relevant Japanese wiring regulation can be applied.
3.2.5A Add the following new clause after 3.2.5 No power cords N/A
provided.
3.2.5A AC mains plug
Mains plug for PLUGGABLE EQUIPMENT TYPE A shall
comply with JIS C 8282-1 or equivalent to or better
performance. Power supply cord set complying with JIS C
8286 is regarded to meet the requirements. Mains plug with
fuse link for PLUGGABLE EQUIPMENT TYPE A shall comply
with JIS C 8282-2-1 or equivalent to or better performance.
Note Mains plug complying with Appendix 4 of the
interpretation of Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance is regarded to have
equivalent to or better performance.
3.3.4 Add the following note to Table 3D: No power cords N/A
Table 3D provided.
Note For cables other than those complying with JIS C 3662
series of standards or JIS C 3663 series of standards, the
terminals shall be suitable for the size of the intended cables.
3.3.7 Add the following after the first sentence: Built-in component. N/A

This requirement is not applicable to the external earthing


terminal of CLASS 0I EQUIPMENT.
4.2.8 Add the following after the first paragraph: No picture tube N/A
used.
Note Intrinsically protected picture tube is required to comply
with JIS C 6965 in clause 18 of JIS C 6065. No intrinsically
protected picture tube which is out of scope of JIS C 6965 is
required to test according to sub-clause 18.2 of JIS C 6065.
Enclosure_1 Page 50 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

4.3.4 Add the following after the first sentence: Built-in component. N/A

This requirement also applies to those connections in CLASS


0I EQUIPMENT, where CLEARANCE or CREEPAGE
DISTANCES over BASIC INSULATION would be reduced to
less than the values specified in 2.10.
4.3.5 Replace the first dashed paragraph with the following. N/A

Within a manufacturer’s unit or system, plugs and sockets


likely to be used by the OPERATOR or by a SERVICE
PERSON shall not be employed in a manner likely to create a
hazard due to misconnection. In particular, connectors
complying with IEC 60320/JIS C 8283 series of standards or
JIS C 8303 or JIS C 8358 shall not be used for SELV
CIRCUITS or TNV CIRCUITS. Keying, location or, in the case
of connectors accessible only to a SERVICE PERSON, clear
markings are permitted to meet the requirement.
4.3.6 Replace the 1st paragraph with the following No direct plug-in N/A
equipment
DIRECT PLUG-IN EQUIPMENT shall not impose undue stress
on the socket-outlet. The mains plug part shall comply with the
standard for the relevant mains plug. (see 3.2.5A)
4.4.2 Replace the paragraph with the following: N/A

HOUSEHOLD AND HOME/OFFICE DOCUMENT/MEDIA


SHREDDERS shall also comply with Annex JA.
4.5.3 Add the following note to footnote b) of Table 4B: Considered. P

NOTE In case no data for the material is available, Appendix 4,


1. (1). b. 3 of the Interpretation on the Ministerial Ordinance
stipulating Technical Specifications for Electrical Appliances is
regarded as maximum temperature limit of the material.
5.1.3 Add a note after the first paragraph as follows: Single-phase N/A
equipment.
Note – Attention should be drawn to that majority of three-
phase power system in Japan is of delta connection, and
therefore, in that case, test is conducted using the test circuit
from IEC 60990, figure 13.
Enclosure_1 Page 51 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

5.1.6 Replace Table 5A. as follows N/A


Type of equipment Terminal A of Maximum Maximum
measuring TOUCH PROTECTI
instrument CURRENT VE
a
connected to: mA r.m.s. CONDUCT
OR
CURRENT
ALL equipment Accessible parts 0,25 -
and circuits not
connected
b
to protective earth
HAND-HELD Main protective 0,75 -
earthing terminal of
CLASS I
EQUIPMENT
Main protective 0,5 -
earthing terminal of
CLASS 0 I
EQUIPMENT
MOVABLE (other than Main protective 3,5 -
HAND_HELD, but earthing terminal of
including CLASS I
TRANSPORTABLE EQUIPMENT
EQUIPMENT) Main protective 1.0 -
earthing terminal of
CLASS 0 I
EQUIPMENT
STATIONARY, Main protective 3,5 -
PLUGGABLE TYPE A earthing terminal of
CLASS I
EQUIPMENT
Main protective 1,0 -
earthing terminal of
CLASS 0 I
EQUIPMENT
ALL other Main protective 3.5 -
STATIONARY earthing terminal of - 5 % of input
EQUIPMENT CLASS I current
- not subject to the EQUIPMENT
conditions of 5.1.7 Main protective 1.0 -
- subject to the earthing terminal of - -
conditions of 5.1.7 CLASS 0 I
EQUIPMENT
a If peak values of TOUCH CURRENT are measured, the maximum values
are obtained by multiplying the r.m.s.values in the table by 1,414.
b Some unearthed accessible parts are covered in 1.5.6 and 1.5.7 and the
requirements of 2.4 apply. These may be different from those in 5.1.6.
Annex G Replace the paragraph before Table G.2 with the following Alternate method not N/A
considered.
The above minimum CLEARANCE for connectors do not apply
to connectors that comply with JIS C 8285, IEC60309 series of
standards, JIS C 8283 series of standards, IEC60320 series of
standards, JIS C 8303, and 1.5.1 of this standard in which
dimension is comply with JIS C 8283 series, JIS C 8303 or IEC
60309-2.
Annex V Replace “3.1.2”in the first line of V.1 with “312” in the first line. Considered. P
V.1
Enclosure_1 Page 52 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

Annex W Replace the third sentence in the first paragraph with the N/A
W.1 following:

Floating circuits can exist in CLASS I EQUIPMENT, CLASS 0I


EQUIPMENT and earthed circuits can exist in CLASS II
EQUIPMENT.
Annex BB This annex is not applicable.
Annex Replace the third dashed paragraph with the following: No such circuits. N/A
CC
CC.2 - 10 000 cycles of turning enable on and off with the input
connected to a capacitor rated
425 uF ± 10 uF and shorting the output;
CC.3 Add note at end of CC.3: N/A
Note: The fast blow fuse should be the one complying
with JIS C 6575-2.
CC.4 Replace the 2nd dashed paragraph with the following:

- 10 000 cycles of turning enable on and off with a 100 Ω± 5


Ω resistor and a
425 uF ± 10 uF capacitor in parallel with the output;

Replace the 4th dashed paragraph with the following:

- 10 000 cycles of turning enable on and off with the input


connected to a capacitor rated
425 uF ± 10 uF and shorting the output;

Replace the 5th dashed paragraph with the following:

−10 000 cycles of turning the input pin on and off with a
capacitor rated 425 uF ± 10 uF
connected to the input supply while keeping enable active and
shorting the output;

Replace the 6th dashed paragraph with the following:

−10 000 cycles of turning the input pin on and off with an
ferrite-core inductor having
350 mH ± 10 mH inductance at 1 kHz and less than 1 Ω d.c.
resistance connected to the
input supply and return while keeping enable active and
shorting the output;

Replace the 10th dashed paragraph with the following:

−3 cycles of exposing the device (not energized) to 70 °C ±


2 °C for 24 h; followed by at
least 1 h at room ambient; followed by at least 3 h at -30 °C ±
2 °C; followed by 3 h at room ambient;
Enclosure_1 Page 53 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

Replace the 11th dashed paragraph with the following:

−10 cycles of exposing the device (while energized) to 50 °C ±


2 °C for 10 min; followed by
10 min at 0 °C ± 2 °C with a 5 min period of transition from one
state to the other;
Annex EE Replace Annex EE with the following Annex JA. N/A

Annex JA
(normative)
Document shredding machines

HOUSEHOLD AND HOME/OFFICE DOCUMENT/MEDIA


SHREDDERS shall additionally comply with the requirements
of this annex.

JA.1 Markings and instructions

The symbol (JIS S 0101:2000, 6.2.1) and the following


precautions for use shall be marked on readily visible part
adjacent to document feed opening. The marking shall be
clearly legible, permanent, and easily discernible;

;
(that use by infants/children may cause a hazard of injury
etc.)

;
(that a hand can be drawn into the mechanical section for
shredding when touching the document-slot)

;
(that clothing can be drawn into the mechanical section for
shredding when touching the document-slot)

;
(that hairs can be drawn into the mechanical section for
shredding when touching the document-slot)
- in case of equipment incorporating a commutator motor,

(that equipment may catch fire or explode by spraying of


flammable gas.)

JA.2 Inadvertent reactivation


Enclosure_1 Page 54 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

Any safety interlock that can be operated by means of the test


finger, Figure JA.1, is considered to be likely to cause
inadvertent reactivation of the hazard.

Compliance is checked by inspection and, where necessary,


by a test with the test finger, Figure JA.1.

JA.3 Disconnection from the mains supply


Document shredding machines shall incorporate an isolating
switch complying with sub-clause 3.4.2 as the device
disconnecting the power of hazardous moving parts. For this
switch, two-position (single-use) switch or multi-position
(multifunction) switch (e.g., slide switch) may be used.
If two-position switch, the positions for “ON” and “OFF” shall be
indicated in accordance with sub-clause 1.7.8. If multi-position
switch, the position for “OFF” shall be indicated in accordance
with sub-clause 1.7.8 and other positions shall be indicated
with proper terms or symbols.

Compliance is checked by inspection.


JA.4 Protection against hazardous moving parts N/A
Any warning shall not be used instead of the structure for
preventing access to hazardous moving parts.

Document shredding machines shall comply with the


following requirements.

Insert the test finger, Figure JA.1, into all openings in


MECHANICAL ENCLOSURES without applying
appreciable force. It shall not be possible to touch
hazardous moving parts with the test finger. This
consideration applies to all sides of MECHANICAL
ENCLOSURES when the equipment is mounted as
intended. Before testing with the test finger, remove the
parts detachable without a tool.

Insert the wedge-probe, Figure JA.2, into the document-


slot. And, against all directions of openings, if straight-
cutting type, a force of 45 N shall apply to the probe, and
90 N if cross-cutting type. In this case, the weight of the
probe is to be factored into the overall applied force.
Before testing with the wedge-probe, remove the parts
detachable without a tool. It shall not be possible to touch
any hazardous moving parts, including the shredding
roller or the mechanical section for shedding, with the
probe.
Enclosure_1 Page 55 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

N/A

Figure JA.1 Test finger


Enclosure_1 Page 56 of 56 Report No. 4788327671

IEC 60950_1F ATTACHMENT


Clause Requirement + Test Result - Remark Verdict

N/A

(Details of the tip of wedge)

Distance from the tip (mm) Thickness of probe (mm)


0 2
12 4
180 24

Note 1 - The thickness of the probe varies linearly, with slope


changes at the respective points shown in the table.
Note 2 –The allowable dimensional tolerance of the probe is;
for ≤ 25 mm: +/- 0.13 mm
for > 25 mm: +/- 0.3 mm.

Figure JA.2 Wedge-probe


Enclosure_2
Page 1 of 29 Report No. 4788327671

Enclosures

Type Supplement Id Description


Photographs 1-01 Overall View (Top) with Cover
Photographs 1-02 Overall View (Bottom) with Cover
Photographs 1-03 Overall View (Top) without Cover (FETA7000T-144)
Photographs 1-04 Overall View (Top) without Cover (FETA7000T-48)
Photographs 1-05 Overall View (Top) without Cover (FETA7000ST-144)
Photographs 1-06 Overall View (Top) without Cover (FETA7000ST-48)
Diagrams 2-01 Inductor (L11)
Schematics + PWB 3-01 Circuit Diagram (FETA7000T-144 and FETA7000T-48)
Schematics + PWB 3-02 Component Layout (FETA7000T-144 and FETA7000T-48)
Schematics + PWB 3-03 PWB Trace (FETA7000T-144 and FETA7000T-48)
Schematics + PWB 3-04 Circuit Diagram (FETA7000ST-144 and FETA7000ST-48)
Schematics + PWB 3-05 Component Layout (FETA7000ST-144 and FETA7000ST-48)
Schematics + PWB 3-06 PWB Trace (FETA7000ST-144 and FETA7000ST-48)
Manuals 4-01 Instruction Manual (FETA7000T-144 and FETA7000T-48)
Manuals 4-02 Instruction Manual (FETA7000ST-144 and FETA7000ST-48)
Miscellaneous 5-01 Drawing of Cover
Miscellaneous 5-02 Drawing of Chassis
Miscellaneous 5-03 Letter of Assurance and Declaration of Conformity on RoHS
Miscellaneous 5-04 Manufacturer’s Declaration under IECEE CB Scheme
Enclosure_2
Page 2 of 29 Report No. 4788327671

Photographs ID 1-01
Enclosure_2
Page 3 of 29 Report No. 4788327671

Photographs ID 1-02
Enclosure_2
Page 4 of 29 Report No. 4788327671

Photographs ID 1-03
Enclosure_2
Page 5 of 29 Report No. 4788327671

Photographs ID 1-04
Enclosure_2
Page 6 of 29 Report No. 4788327671

Photographs ID 1-05
Enclosure_2
Page 7 of 29 Report No. 4788327671

Photographs ID 1-06
Enclosure_2
Page 8 of 29 Report No. 4788327671

Diagrams ID 2-01
Enclosure_2
Page 9 of 29 Report No. 4788327671

Diagrams ID 2-01
Enclosure_2
Page 24 of 29 Report No. 4788327671

Miscellaneous ID 4-01
Enclosure_2
Page 25 of 29 Report No. 4788327671

Miscellaneous ID 4-02
Enclosure_2
Page 28 of 29 Report No. 4788327671

Miscellaneous ID 5-03
Enclosure_2
Page 29 of 29 Report No. 4788327671

Miscellaneous ID 5-04