TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number .............................. : 4788327671
Date of issue ................................... : 2018-04-05
Total number of pages ..................... : 95
Applicant’s name........................... : Cosel Co., Ltd.
Address ........................................... : 1-6-43 Kamiakae-machi, Toyama-shi, Toyama 930-0816, Japan
Test specification:
Standard ........................................... : IEC 62368-1:2014 (Second Edition)
IEC 60065:2014 (Eighth Edition)
IEC 60950-1:2005 (Second Edition) + A1:2009 + A2:2013
Test procedure .................................. : CB Scheme
Non-standard test method ................. : N/A
Test Report Form No. ...................... : IEC62368_1&IEC60065&IEC60950_1A
Test Report Form(s) Originator .......... : UL(US)
Master TRF ....................................... : 2015-06
Copyright © 2015 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
TESTING:
Date of receipt of test item .......................................... : 2016-10-24, 2016-11-25, 2017-12-21
Date (s) of performance of tests.................................. : 2016-10-24, 2016-12-06 to 2017-01-13, 2018-01-16 to
2018-02-19, 2018-03-29
GENERAL REMARKS:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
This Test Report covers test results for IEC 62368-1: 2014 (Second Edition), and additional results for IEC
60065: 2014 (Eighth Edition) and/or IEC 60950-1: 2005 (Second Edition) + Am 1: 2009 + Am 2: 2013.
Where a requirement in IEC 62368-1 addresses the same requirement/principle in IEC 60065 and/or IEC
60950-1, compliance with the IEC 62368-1 requirements covers compliance with the same requirement/principle
in IEC 60065 and/or IEC 6095-1, as indicated.
The complete background/rationale behind the considerations in this TRF is outlined in 108/575/INF, IEC TC
108 position related to TRFs associated with the transition of IEC 60065 and IEC 60950-1 to IEC 62368-1. Use
of this TRF is intended to allow for a smooth transition from the legacy standards, IEC 60065 and IEC 60950-1,
to the state-of-art requirements for safety of audio/video, information and communication technology equipment,
IEC 62368-1.
Model FETA7000T series are intended to be used in end-product which connected to three phase star system
and delta system.
Model FETA7000ST series are intended to be used in end-product which connected to three phase, four wire,
(3/N/PE) system.
This Switching Power Supply unit has three units of CB certified component Power Supply Units (PS1, PS2 and
PS3).
Output ratings:
Model FETA7000T-48 and FETA7000ST-48: 48Vdc (21.6-52.8Vdc), 148.2A, maximum 7113W
Model FETA7000T-144 and FETA7000ST-144: 144Vdc (64.8-158.4Vdc), 52.0A, maximum 7488W
- FETA7000T-48 and FETA7000T-144: Three-phase, three wire, delta system and star system power supply
connection
- FETA7000ST-48 and FETA7000ST-144: Three-phase, four wire, (3/N/PE) system power supply connection
Based on attached the IEC 60950-1 informative report (see attached Enclosure 1) and the review of product
construction, only following tests were deemed necessary.
- 5.2: Classification of electrical energy sources
- 5.5.2.2: Capacitor discharge test
- 5.7: Prospective Touch Voltage and Touch Current Measurement
In this Test Report, CENELEC mark license indicating compliance to EN standard was used to verify component
compliance to IEC standard because the standards are technically equivalent.
The Clearances and Creepage Distances have additionally been assessed for suitability up to 3000 m elevation.
Technical Considerations
- The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by
the manufacturer’s specification of: 60°C. (See Enclosure Id. 4-01 and 4-02 for details of output derating
upon the factors including ambient temperature.)
- Models FETA7000T-48 and FETA7000ST-48 were tested with output voltage range of 21.6 – 52.8Vdc
(maximum 7113W), Models FETA7000T-144 and FETA7000ST-144 were tested with output voltage range
of 64.8 – 158.4Vdc (maximum 7488W), Adjustment was made via component VR31.
- The end-product Electric Strength Test shall take into account the maximum working voltage of: Primary-
Ground: 428 Vrms, 976Vpk, Primary-Secondary: 349 Vrms, 1050 Vpk
- The following secondary output circuits are ES1: 48Vdc output of Models FETA7000T-48 and
FETA7000ST-48, and interface circuit (CN1, CN2) of all models.
- The following secondary output circuits are PS3: Outputs of all models except for AUX output
- The following secondary output circuits are limited power source: AUX output
- The power supply terminals and/or connectors are: Suitable for factory wiring only
- Proper bonding to the end-product main protective earthing termination is: Required (Chassis or cover)
- The following input connectors must be connected to the end-product supply neutral: TB2 Pin 2 (N) (Indicate
near the TB2 for models FETA7000ST-48 and FETA7000ST-144).
- This component has been evaluated in ‘control of fire spread’ method assuming appropriate fire enclosure is
provided in end product. Unless the fire enclosure is made of non-combustible or V-0 material, the
separation from the PIS (all electrical components) shall be considered.
- Mains Supply Source is assumed to both Delta system and Star system during the tests for model
FETA7000T-48 and FETA7000T-144.
- Mains Supply Source is assumed to Star system during the tests for model FETA7000ST-48 and
FETA7000ST-144.
☐ ES ☐ PS ☐ MS ☐ TS ☐ RS
4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and Secondary internal wire is accepted P
subassemblies base on compliance with IEC
(IEC 60065, 3.4) & (IEC 60950-1, 1.5.1) 60950-1.
4.7 Equipment for direct insertion into mains socket – No such equipment. N/A
outlets
(IEC 60065, 15.4) & (IEC 60950-1, 4.3.6)
5 ELECTRICALLY-CAUSED INJURY P
5.2.1 Electrical energy source classifications ............. : See appended table 5.2
5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current ...................... : See appended table 5.2.2.2
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.2, 2.3, 2.4)
5.2.2.3 Capacitance limits............................................ : See appended table 5.2.2.3
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.4)
5.2.2.4 Single pulse limits ............................................ : No single pulse.
(IEC 60950-1, 2.2)
5.2.2.5 Limits for repetitive pulses ................................ : No repetitive pulse.
(IEC 60950-1, 2.2)
5.2.2.6 Ringing signals ............................................... : No ringing signals.
(IEC 60950-1, 2.3, Annex M)
5.2.2.7 Audio signals .................................................. : No audio signals.
(IEC 60065, 9.1.1.2) & (IEC 60950-1, 2.1.1.9)
5.3 Protection against electrical energy sources P
(IEC 60065, 9.1.1) & (IEC 60950-1, 2.1)
5.3.1 General Requirements for accessible parts to (for Models FETA7000T-48 and P
ordinary, instructed and skilled persons FETA7000ST-48)
(IEC 60065, 9.1.1) & (IEC 60950-1, 2.1) Secondary ES1 outputs are
assumed to be accessible in end
product application.
5.3.2.1 Accessibility to electrical energy sources and Building-in component. N/A
safeguards Final compliance to be evaluated
(IEC 60065, 9.1.1.3, 9.1.2, 9.1.3, 9.1.4, 9.1.5) & in end-product.
(IEC 60950-1, 2.1.1.1)
5.3.2.2 Contact requirements N/A
(IEC 60065, 9.1.1.1) & (IEC 60950-1, 2.1.1.1)
a) Test with test probe from Annex V ................ :
b) Electric strength test potential (V) ................. :
c) Air gap (mm) ............................................... :
5.3.2.4 Terminals for connecting stripped wire N/A
(IEC 60065, 9.1.1.4)
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material P
(IEC 60065, 8.3) & (IEC 60950-1, 2.9.1)
5.4.1.3 Humidity conditioning ...................................... : See sub-clause 5.4.8
(IEC 60065, 10.3)
(IEC 60950-1, 2.9.1)
5.4.1.4 Maximum operating temperature for insulating See appended table 5.4.1.4
materials ......................................................... :
(IEC 60065, 7.1) & (IEC 60950-1, 4.5)
5.4.1.5 Pollution degree............................................... : 2
(IEC 60065, 13.1) & (IEC 60950-1, 2.10.1.2)
5.4.1.5.2 Test for pollution degree 1 environment and for an No such insulating parts. N/A
insulating compound
(IEC 60065, 13.6, 13.7) & (IEC 60950-1, 2.10.10)
5.4.1.5.3 Thermal cycling N/A
(IEC 60065, 13.6) & (IEC 60950-1, 2.10.9)
5.4.1.6 Insulation in transformers with varying dimensions No such transformer. N/A
(IEC 60065, 13.2) & (IEC 60950-1, 2.10.1.5)
5.4.1.7 Insulation in circuits generating starting pulses No circuits generating starting N/A
(IEC 60950-1, 2.10.3.5) pulses.
5.4.4.9 Solid insulation at frequencies >30 kHz ........... : See appended Table 5.4.4.9
5.4.5 Antenna terminal insulation No antenna terminal. N/A
(IEC 60065, 10.2) & (IEC 60950-1, 7.4)
5.4.5.1 General N/A
5.4.5.2 Voltage surge test N/A
(IEC 60065, 10.2) & (IEC 60950-1, 7.4.2)
Insulation resistance (M)............................... :
5.4.6 Insulation of internal wire as part of No such internal wire.
supplementary safeguard ................................ :
(IEC 60065, 8.9) & (IEC 60950-1, 2.1.1.3)
5.4.7 Tests for semiconductor components and for N/A
cemented joints
(IEC 60065, 13.6, 13.7, 13.8) & (IEC 60950-1,
2.10.11)
5.4.8 Humidity conditioning P
(IEC 60065, 10.3) & (IEC 60950-1, 2.9.2)
Relative humidity (%) ...................................... : 93 %
Temperature (°C) ........................................... : 25 °C
Duration (h) .................................................... : 48 hours
5.4.9 Electric strength test ........................................ : See appended table 5.4.9
(IEC 60065, 10.4) & (IEC 60950-1, 5.2)
5.4.9.1 Test procedure for a solid insulation type test P
(IEC 60065, 10.4) & (IEC 60950-1, 5.2)
5.4.9.2 Test procedure for routine tests N/A
(IEC 60065, N.3.2) & (IEC 60950-1, 5.2.2)
5.4.10 Protection against transient voltages between Building-in component. N/A
external circuit No connection to such external
(IEC 60065, Annex B) & (IEC 60950-1, 6.2) circuit.
5.4.10.1 Parts and circuits separated from external circuits N/A
(IEC 60950-1, 6.2.1)
5.4.10.2 Test methods N/A
(IEC 60950-1, 6.2.2)
10 RADIATION N/A
10.2 Radiation energy source classification No radiation energy source as N/A
specified in this standard is present.
10.2.1 General classification N/A
10.3 Protection against laser radiation No laser. N/A
(IEC 60065, 6.2) & (IEC 60950-1, 4.3.13.5.1)
Laser radiation that exists equipment .................:
Normal, abnormal, single-fault ...........................:
Instructional safeguard ......................................:
Tool...................................................................:
10.4 Protection against visible, infrared, and UV No UV radiation. N/A
radiation
(IEC 60065, 6.3) & (IEC 60950-1, 4.3.13.4,
4.3.13.5.2)
10.4.1 General N/A
10.4.1.a) RS3 for Ordinary and instructed persons ...........:
10.4.1.b) RS3 accessible to a skilled person ....................:
Personal safeguard (PPE) instructional safeguard
.........................................................................:
10.4.1.c) Equipment visible, IR, UV does not exceed RS1 :
10.4.1.d) Normal, abnormal, single-fault conditions .........:
10.4.1.e) Enclosure material employed as safeguard is
opaque ..............................................................:
B.4.4.1 Short circuit of clearances for functional insulation See appended table B.4 P
B.4.4.2 Short circuit of creepage distances for functional See appended table B.4 P
insulation
B.4.4.3 Short circuit of functional insulation on coated No coated printed board. N/A
printed boards
B.4.5 Short circuit and interruption of electrodes in See appended table B.4 P
tubes and semiconductors
(IEC 60065, 4.3.4) & (IEC 60950-1, 5.3.7)
B.4.6 Short circuit or disconnect of passive components See appended table B.4 P
(IEC 60065, 4.3.5) & (IEC 60950-1, 5.3.7)
B.4.7 Continuous operation of components No applicable component. N/A
(IEC 60065, 4.3.8) & (IEC 60950-1, 5.3.5)
B.4.8 Class 1 and Class 2 energy sources within limits See appended table B.4 P
during and after single fault conditions
(IEC 60065, 11) & (IEC 60950-1, 5.3.9)
B.4.9 Battery charging under single fault conditions .... : No battery. N/A
(IEC 60065, 14.11.3) & (IEC 60950-1, 4.3.8)
C UV RADIATION N/A
C.1 Protection of materials in equipment from UV No ultraviolet light source. N/A
radiation
(IEC 60950-1, 4.3.13.3)
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
(IEC 60950-1, Annex Y)
C.2.1 Test apparatus N/A
(IEC 60950-1, Y.1)
C.2.2 Mounting of test samples N/A
(IEC 60950-1, Y.2)
C.2.3 Carbon-arc light-exposure apparatus N/A
(IEC 60950-1, Y.3)
C.2.4 Xenon-arc light exposure apparatus N/A
(IEC 60950-1, Y.4)
G COMPONENTS P
G.1 Switches N/A
(IEC 60950-1, 2.8.7)
G.1.1 General requirements Not used. N/A
(IEC 60065, 14.7)
G.1.2 Ratings, endurance, spacing, maximum load N/A
(IEC 60065, 14.7)
G.2 Relays N/A
(IEC 60065, 14.4.3) & (IEC 60950-1, 2.8.7)
G.2.1 General requirements Not used. N/A
G.2.2 Overload test N/A
(IEC 60950-1, 2.8.7.2)
Position ............................................................ :
G.5.4.2 Test conditions N/A
(IEC 60065, 4.3.7, 14.10) & (IEC 60950-1, B.2)
Type ................................................................. :
Rated current (A)............................................... :
2
Cross-sectional area (mm ), (AWG)................... :
G.7.2 Compliance and test method N/A
(IEC 60065, 16.2) & (IEC 60950-1, 3.2.5.1)
G.7.3 Cord anchorages and strain relief for non- N/A
detachable power supply cords
G.7.3.2 Cord strain relief N/A
G.7.3.2.1 Requirements N/A
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.6)
Strain relief test force (N)................................... :
G.7.3.2.2 Strain relief mechanism failure N/A
(IEC 60950-1, 3.2.6)
G.7.3.2.3 Cord sheath or jacket position, distance (mm) ... :
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.7)
G.7.3.2.4 Strain relief comprised of polymeric material N/A
(IEC 60065, 16.5) & (IEC 60950-1, 3.2.6, 3.2.7)
G.7.4 Cord Entry......................................................... :
(IEC 60950-1, 3.1.4, 3.2.7)
G.7.5 Non-detachable cord bend protection N/A
G.7.5.1 Requirements N/A
(IEC 60950-1, 3.2.8)
G.7.5.2 Mass (g) ........................................................... :
Diameter (m) ..................................................... :
Temperature (C) .............................................. :
G.7.6 Supply wiring space N/A
(IEC 60950-1, 3.2.9)
G.7.6.2 Stranded wire N/A
(IEC 60950-1, 3.3.8)
G.7.6.2.1 Test with 8 mm strand N/A
(IEC 60950-1, 3.3.8)
G.8 Varistors N/A
G.8.1 General requirements Not used. N/A
G.8.2 Safeguard against shock N/A
(IEC 60065, 14.13) & (IEC 60950-1, Annex Q)
G.8.3 Safeguard against fire N/A
G.8.3.2 Varistor overload test ........................................ :
(IEC 60065, 14.13)
G.8.3.3 Temporary overvoltage...................................... :
G.13.3 Coated printed boards Coating not used for insulation. N/A
(IEC 60065, 13.5.2) & (IEC 60950-1, 2.10.6.2)
G.13.4 Insulation between conductors on the same inner N/A
surface
(IEC 60950-1, 2.10.6.3)
Compliance with cemented joint requirements
(Specify construction) ........................................ :
(IEC 60065, 13.5.2, 13.6, 13.7) & (IEC 60950-1,
2.10.5.5)
G.13.5 Insulation between conductors on different N/A
surfaces
(IEC 60065, 13.5.1) & (IEC 60950-1, 2.10.6.4)
Distance through insulation ................................ :
Number of insulation layers (pcs) ..................... :
G.13.6 Tests on coated printed boards Coating not used for insulation. N/A
(IEC 60065, 13.5.2) & (IEC 60950-1, 2.10.8)
G.13.6.1 Sample preparation and preliminary inspection N/A
(IEC 60950-1, 2.10.8.1)
G.13.6.2a) Thermal conditioning N/A
(IEC 60950-1, 2.10.8.2)
G.13.6.2b) Electric strength test N/A
(IEC 60950-1, 2.10.8.3)
Core Case of Wintech Polymer CRN7000 PBT, RTI: 140 C, IEC 60695-11- UL (E213445)
Inductor (L11) Ltd. V-0, Minimum 0.32 10
(for model mm thick.
FETA7000T-48,
FETA7000T-144)
Y-Capacitors (C14, Murata Mfg. Co., KX (PRI-to-GND) 250 IEC 60384-14 VDE
C15, C16) (for Ltd. V, 3300 pF, Class (40002831)
model FETA7000T- Y1 UL (E37921)
UL 60384-14
48, FETA7000T-
144)
Y-Capacitor (C15) Murata Mfg. Co., KX (Neutral-to-GND) IEC 60384-14 VDE
(for model Ltd. 250 V, 3300 pF, (40002831)
FETA7000ST-48, Class Y1 UL 60384-14 UL (E37921)
FETA7000ST-144)
Switching Power Cosel Co., Ltd. FETA2500BA- (PRI/SEC/GND) IEC 60950-1, UL (CB)
Supplies (PS1, PS2, 48 Input: 200-240Vac IEC 62368-1 (4788327644)
PS3) 50-60Hz 13.8 A UL 60950-1 UL (E132067)
Output: 48Vdc 52A
4.8.4, 4.8.5 TABLE: Lithium coin/button cell batteries mechanical tests N/A
(The following mechanical tests are conducted in the sequence noted.)
4.8.4.2 TABLE: Stress relief test
Part Material Oven Temperature (°C) Comments
-- -- -- --
4.8.4.3 TABLE: Battery replacement test
Battery part no. ............................................................ : —
Battery Installation/withdrawal Battery Installation/Removal Cycle Comments
1 --
2 --
3 --
4 --
5 --
6 --
8 --
9 --
10 --
4.8.4.4 TABLE: Drop test
-- -- 1 --
-- -- 2 --
-- -- 3 --
4.8.4.5 TABLE: Impact
Impacts per surface Surface tested Impact energy (Nm) Comments
-- -- -- --
4.8.4.6 TABLE: Crush test
Test position Surface tested Crushing Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:
No battery used.
4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result N/A
Test position Surface tested Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:
No battery used.
Single fault – -- -- --
SC/OC
2 240 Vac, 60 48 Vdc output Normal ($) 52.8 Vdc -- DC
Hz (model
FETA7000T-
48) (###) Abnormal 55.35 Vdc -- DC
VR31 maximum ES1
Volume
Single fault – Maximum 52.8 -- DC
SC/OC Vdc
R418 SC
3 240 Vac, 60 AUX output Normal (4+) Maximum 12.1 -- DC
Hz (CN2 (CN1) 1 Vdc (+)
pin to 2 pin) of
model Maximum 12.1 -- DC
FETA7000T- Vdc (3+)
144 (#) (##)
Single fault – Maximum 27.99 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 11.95 -- DC
T701 4 pin SC Vdc (3+)
(4+)
Single fault – Maximum 42.78 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 11.99 -- DC ES1
D810 (K) SC Vdc (3+)
(4+)
Single fault – Maximum 32.8 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 10.58 -- DC
D811 (K) SC Vdc (3+)
(4+)
Single fault – Maximum 26.0 -- DC
SC/OC Vdc (+)
Vss_ORMDS to Maximum 12.05 -- DC
T701 2 pin SC Vdc (3+)
(4+)
Abnormal -- -- --
Single fault – -- -- --
SC/OC
Test Conditions:
Normal – maximum Voltage with in output voltage range.
Supplementary information: SC=Short Circuit, OC=Short Circuit
(+) CN2 (CN1) 1pin is connected to Ground.
(2+) For FETA7000T-144 (Maximum voltage within output voltage range: 158.4V, 47.28A)
(3+) CN2 (CN1) 1pin is not connected to Ground (floating).
(4+) For PS1 (FETA2500BA-48)
(#) Test performed on Model FETA7000T-144 representative of model FETA7000ST-144 because secondary
circuits are identical.
(##) This test was performed to confirm whether the output of model FETA7000T-144 would affect interface circuit.
Interface circuits are connected to AUX circuits of the certified component power supply FETA2500BA-48.
Therefore, voltage between CN2 (CN1) 1 pin and 2 pin connected to AUX circuits was measured as
representative. This measurement covers all interface circuits.
(###) Test performed on Model FETA7000T-48 representative of model FETA7000ST-48 because secondary
circuits are identical.
(2#) Test performed on Model FETA7000T-144 representative of model FETA7000T-48 because primary circuits
are identical.
(3#) Test performed on Model FETA7000ST-144 representative of model FETA7000ST-48 because primary
circuits are identical.
($) This result is referred to the result of 48 Vdc output of Model FETA2500BA-48, Because 48 Vdc outputs of
Models FETA7000T series and FETA7000ST series are is connected to 48 Vdc output of Model FETA2500BA-48
directly.
Ambient 27 -- 27 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 67 80 58 71 130 (TB1)
Terminal Block (TB3) 70 83 62 75 130 (TB3)
Inductor (L11) 105 118 78 91 140 (RTI)
Capacitor (C13) 78 91 66 79 110 (C13)
Capacitor (C16) 73 86 62 75 125 (C16)
Capacitor (C21) 74 87 65 78 110 (C21)
PWB near TB211 77 90 67 80 130 (PWB)
PWB near IC491 80 93 70 83 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 96 74 87 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 93 106 83 96 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 83 96 74 87 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 91 104 83 96 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 80 93 71 84 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 87 100 76 89 130 (RTI)
Transformer (T301) coil Pri. side (FETA2500BA- 95 108 85 98 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 101 114 90 103 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 82 95 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 100 113 91 104 130 (PWB)
Inductor (L101) (FETA2500BA-48/PS2) 53 66 39 52 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 55 68 41 54 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 93 106 84 97 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 77 90 67 80 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 80 93 70 83 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 84 97 75 88 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 92 105 82 95 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 81 94 72 85 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 99 112 90 103 130 (PWB)
Ambient 28 -- 26 -- --
Tma -- 40 -- 40 --
Terminal Block (TB1) 63 75 55 69 130 (TB1)
Terminal Block (TB3) 61 73 54 68 130 (TB3)
Capacitor (C11) 72 84 62 76 110 (C11)
Capacitor (C15) 70 82 59 73 125 (C15)
Capacitor (C21) 67 79 58 72 110 (C21)
PWB near TB211 78 90 67 81 130 (PWB)
PWB near IC491 78 90 68 82 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 83 95 74 88 130 (Class F)
48/PS1)
Transformer (T301) coil Sec. side (FETA2500BA- 83 95 74 88 130 (Class F)
48/PS1)
Transformer (T701) coil (FETA2500BA-48/PS1) 76 88 66 80 110 (Class B)
PWB near T301 (FETA2500BA-48/PS1) 94 106 85 99 130 (PWB)
PWB near T701 (FETA2500BA-48/PS1) 70 82 59 73 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 79 91 68 82 130 (Class F)
48/PS2)
Transformer (T301) coil Sec. side (FETA2500BA- 86 98 76 90 130 (Class F)
48/PS2)
Transformer (T701) coil (FETA2500BA-48/PS2) 80 92 69 83 110 (Class B)
PWB near T301 (FETA2500BA-48/PS2) 106 118 96 110 130 (PWB)
PWB near T701 (FETA2500BA-48/PS2) 75 87 64 78 130 (PWB)
Terminal Block (TB101) (FETA2500BA-48/PS2) 85 97 74 88 130 (RTI)
Inductor (L101) (FETA2500BA-48/PS2) 54 66 38 52 140 (RTI)
Inductor (L102) near R101 (FETA2500BA-48/PS2) 53 65 38 52 140 (RTI)
Inductor (L301) (FETA2500BA-48/PS2) 65 77 43 57 150 (RTI)
PWB near TR302 (FETA2500BA-48/PS2) 77 89 66 80 130 (PWB)
Transformer (T301) coil Pri. side (FETA2500BA- 73 85 62 76 130 (Class F)
48/PS3)
Transformer (T301) coil Sec. side (FETA2500BA- 81 93 74 88 130 (Class F)
48/PS3)
Transformer (T701) coil (FETA2500BA-48/PS3) 78 90 70 84 110 (Class B)
PWB near T301 (FETA2500BA-48/PS3) 92 104 84 98 130 (PWB)
PWB near T701 (FETA2500BA-48/PS3) 69 81 61 75 130 (PWB)
Supply voltage/ frequency 311Vac 311Vac -- -- --
/60Hz /60Hz
Supplementary information:
Note 1: Only for frequency above 30 kHz
Note 2: See table 5.4.2.4 if this is based on electric strength test
Note 3: Provide Material Group
(+) FETA7000T-144/-48
(2+) FETA2500BA-48
(3+) FETA7000ST-144/-48
The value in the above table is the required clearance of operated at up to 3000 m sea level. The multiplication
factors of table 17 applied. For operation up to 2000 m sea level, see the value in the parentheses.
2* N/A
3 N/A
(For fig.4)
4, Phase R line open, Phase R switch e close:
line connected to FG 0.001, switch e
open: 0.063,
(For fig.5)
switch e close:
0.001, switch e
open: 0.063
(For fig.4)
switch e close:
0.001, switch e
4, Phase R line open, Phase S open: 2.524,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.524
(For fig.4)
switch e close:
0.001, switch e
4, Phase R line open, Phase T open: 2.528,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.534
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase R open: 2.556,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.550
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase S open: 0.080,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 0.080
(For fig.4)
switch e close:
0.001, switch e
4, Phase S line open, Phase T open: 2.546,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.553
(For fig.4)
switch e close:
0.001, switch e
4, Phase T line open, Phase R open: 2.522,
line connected to FG (For fig.5)
switch e close:
0.001, switch e
open: 2.530
4, Phase T line open, Phase S (For fig.4)
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.40,
4, Phase S line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.40
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.37, Reverse:
1.41,
4, Phase T line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
1.36, Reverse:
1.41
5 N/A
6 N/A
8 N/A
Model: FETA7000ST-144 / Star
--
system
(For fig.4)
Normal: 0.12,
1, switch e open, Capacitor (C15) Reverse: 0.12,
disconnected (For fig.5)
Normal: 0.14,
Reverse: 0.14
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
4, Phase L1 line open open: Normal:
0.66, Reverse:
0.67,
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.67, Reverse:
0.66
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66,
4, Phase L2 line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66
(For fig.4)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66,
4, Phase L3 line open
(For fig.5)
switch e close:
Normal: 0.001,
Reverse:
0.001, switch e
open: Normal:
0.66, Reverse:
0.66
5 N/A
6 N/A
8 N/A
Supplementary Information:
Notes:
[1] Supply voltage is the anticipated maximum Touch Voltage
[2] Earthed neutral conductor [Voltage differences less than 1% or more]
[3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3
[4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable.
[5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g., appliance coupler)
provided.
An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the product of
the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than 15.
All circuits are considered as PIS.
-- -- -- -- -- --
Supplementary Information:
FETA7000T- -- -- -- -- -- -- --
144
Power -- -- -- -- -- -- 3 PHASE, Star
Source system
Connection
200 24.5, 23.9 -- -- (+) 24.5, 50 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
200 24.5, 23.9 -- -- (+) 24.5, 60 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
200 24.0, 23.9 -- -- (+) 24.0, 50 Hz, 158.4 V, 47.28
24.5, 24.5, A
24.0 24.0
200 24.0, 23.9 -- -- (+) 24.0, 60 Hz, 158.4 V, 47.28
24.5, 24.5, A
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 158.4 V, 47.28
20.0, 20.0, A
20.0 20.0
Power -- -- -- -- -- -- 3 PHASE, Delta
Source system, Gnd
Connection connected to R line.
200 24.5, 23.9 -- -- (+) 24.5, 50 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
200 24.5, 23.9 -- -- (+) 24.5, 60 Hz, 144 V, 52 A
24.5, 24.5,
24.0 24.0
240 20.0, 23.9 -- -- (+) 20.0, 50 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
240 20.0, 23.9 -- -- (+) 20.0, 60 Hz, 144 V, 52 A
20.0, 20.0,
20.0 20.0
FETA7000ST -- -- -- -- -- -- --
-144
Power -- -- -- -- -- -- 3 PHASE, Star
Source (3/N/PE) system
Connection
346/200 13.6, 13.8 -- -- (+) 13.6, 50 Hz, 144 V, 52 A
13.8, 13.8,
13.8 13.8
346/200 13.6, 13.8 -- -- (+) 13.6, 60 Hz, 144 V, 52 A
13.8, 13.8,
13.8 13.8
415/240 11.4, 13.8 -- -- (+) 11.4, 50 Hz, 144 V, 52 A
11.6, 11.6,
11.6 11.6
415/240 11.4, 13.8 -- -- (+) 11.4, 60 Hz, 144 V, 52 A
11.6, 11.6,
11.6 11.6
346/200 13.6, 13.8 -- -- (+) 13.6, 50 Hz, 158.4 V, 47.28
13.8, 13.8, A
13.8 13.8
346/200 13.6, 13.8 -- -- (+) 13.6, 60 Hz, 158.4 V, 47.28
13.8, 13.8, A
13.8 13.8
415/240 11.2, 13.8 -- -- (+) 11.2, 50 Hz, 158.4 V, 47.28
11.4, 11.4, A
11.4 11.4
415/240 11.2, 13.8 -- -- (+) 11.2, 60 Hz, 158.4 V, 47.28
11.4, 11.4, A
11.4 11.4
Supplementary information:
(+) Branch circuit breaker, Rated 50A.
52.8V output Short 264 Vac 1 second (+) -- (+) (+) Unit shut down no
/60Hz (2+) damaged.
NB, NC, NT,
Ambient: 25 °C
52.8V output Overload 264 Vac 7 hours, (+) 22.0, (+) (+) Maximum
/60Hz (2+) 21 21.5, continuous
temperature was
minutes. 22.0 obtained at 52.07V,
173A load.
T301 coil (Sec.
side) of PS1:
101 °C.
T701 coil of PS1:
81 °C.
T301 coil (Sec.
side) of PS2:
107 °C.
T701 coil of PS2:
82 °C.
T301 coil (Sec.
side) of PS3:
101 °C.
T701 coil of PS3:
80 °C.
Then temperature
decreased when
further loaded over
173 A load.
NB, NC, NT,
Ambient: 25°C
Model -- -- -- -- -- -- -- --
FETA7000T-
144
158.4V output Short 264 Vac 1 (+) -- (+) (+) Unit shut down no
/60Hz (2+) seccond damaged.
NB, NC, NT,
Ambient: 25 °C
158.4V output Overload 264 Vac 4 hours, (+) 22.0, (+) (+) Maximum
/60Hz (2+) 48 22.0, continuous
minutes. 22.0 temperature was
obtained at 157.6
V, 56.8 A. load.
T301 coil (Sec.
side) of PS1:
101 °C.
T701 coil of PS1:
81 °C.
T301 coil (Sec.
side) of PS2:
108 °C.
T701 coil of PS2:
84 °C.
T301 coil (Sec.
side) of PS3:
100 °C.
T701 coil of PS3:
80 °C.
Then temperature
decreased when
further loaded over
56.8 A load.
NB, NC, NT,
Ambient: 26 °C
Supplementary information:
Test table is provided to record abnormal and fault conditions for all applicable energy sources including
Thermal burn injury. Column “Abnormal/Fault.” Specify if test condition by indicating “Abnormal” then the
condition for a Clause B.3 test or “Single Fault” then the condition for Clause B.4.
(+) Branch circuit breaker, Rated 50A.
(2+) Power Source Connection: 3 PHASE, Delta System,
CT - Constant temperatures were obtained
NB - No indication of dielectric breakdown
NC - Cheesecloth remained intact
NT - Tissue paper remained intact
Test performed on models FETA7000T-144 and FETA7000T-48 representative of models FETA7000ST-144
and FETA7000ST-48 because the difference between each other is only the difference between the primary
part and the supply power source at a level that is not affected by the above test results.
Component -- -- -- -- -- -- -- --
Failure Test
Model -- -- -- -- -- -- -- --
FETA7000T-144
PC481 (Primary Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
side) /60Hz (2+) minutes 18.5 normal.
NB, NC ,NT,
Ambient:
25 °C
PC481 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
PC482 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Primary side) /60Hz (2+) minutes 18.5 normal.
NB, NC, NT,
Ambient:
25 °C
PC482 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
PC461 Short 264Vac 1 second (+) -- -- -- Unit shit down
(Primary side) /60Hz (2+) no damaged.
NB, NC, NT,
Ambient:
25 °C
PC461 Short 264Vac 15 (+) 18.5, 18.5, -- -- Unit operated
(Secondary /60Hz (2+) minutes 18.5 normal.
side) NB, NC, NT,
Ambient:
25 °C
TR491 Short 264Vac 15 (+) 15.0, 17.0, -- -- Output down:
(C to E) /60Hz (2+) minutes 15.0 144V, 52A
>124V 52A.
Unit kept the
operation
aftre short
test.
NB, NC, NT,
Ambient:
25 °C
Annex M.4 TABLE: Additional safeguards for equipment containing secondary lithium N/A
batteries
Battery/Cell Measurements
Test conditions Observation
No.
U I (A) Temp (C)
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault –SC/OC -- -- -- --
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault – SC/OC -- -- -- --
Supplementary Information:
Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) P
Note: Measured UOC (V) with all load circuits disconnected:
Output Components Uoc (V) Isc (A) S (VA)
Circuit
Meas. Limit Meas. Limit
-- -- -- -- -- -- --
Supplementary Information:
SC=Short circuit, OC=Open circuit
See Annex Q.
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex G Power supply cords are required to have Building-in component. N/A
(G.7.3) attachment plugs rated not less than 125 No power supply cord.
percent of the rated current of the equipment.
Flexible power supply cords are required to be N/A
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
Annex H.4 For circuits with other than ringing signals and N/A
with voltages exceeding 42.4 Vpeak or 60 V d.c.,
the maximum acceptable current through a
2000 ohm resistor (or greater) connected across
the voltage source with other loads
disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
Annex M Battery packs for stationary applications comply No battery pack. N/A
with special component requirements.
Page 6 of 9 Report No. 4788327671
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex DVA Equipment intended for use in spaces used for Building-in component. N/A
(1) environmental air are subjected to special
flammability requirements for heat and visible
smoke release.
For ITE room applications, automated N/A
information storage systems with combustible
3
media greater than 0.76 m (27 cu ft) have a
provision for connection of either automatic
sprinklers or a gaseous agent extinguishing
system with an extended discharge.
Consumer products designed or intended N/A
primarily for children 12 years of age or younger
are subject to additional requirements in
accordance with U.S. & Canadian Regulations.
Annex DVA For Pluggable Equipment Type A, the protection Building-in component. N/A
(5.6.3) in the installation is assumed to be 20A.
Annex DVA The maximum quantity of flammable liquid No flammable liquid used. N/A
(6.3) stored in equipment complies with NFPA 30.
Annex DVA For ITE room applications, enclosures with Building-in component. N/A
(6.4.8) combustible material measuring greater than
0.9 m2 (10 sq ft) or a single dimension greater
than 1.8 m (6 ft) have a flame spread rating of
50 or less. For equipment with the same
dimensions for other applications, an external
surface that is not a fire enclosure requires a
min. flammability classification of V-1.
Annex DVA Equipment with lasers meets the U.S. Code of No lasers. N/A
(10.3.1) Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act,
REDR C1370).
Annex DVA Equipment that produces ionizing radiation No ionizing radiation. N/A
(10.5.1) complies with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
Page 7 of 9 Report No. 4788327671
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex DVA Equipment for use on a.c. mains supply systems Single phase. N/A
(F.3.3.3) with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
Additional considerations apply for voltage
ratings that exceed the attachment cap rating or
are lower than the “Normal Operating Condition”
in Table 2 of CAN/CSA C22.2 No. 235.”
Annex DVA Equipment identified for ITE (computer) room Building-in component. N/A
(F.3.3.5) installation is marked with the rated current
Annex DVA Vertically-mounted disconnect switches and No switch used. N/A
(G.1) circuit breakers have the "on" position indicated
by the handle in the up position
Annex DVA Suitable NEC/CEC branch circuit protection Building-in component. N/A
(G.3.4) rated at the maximum circuit rating is required
for all standard supply outlets and receptacles
(such as supplied in power distribution units) if
the supply branch circuit protection is not
suitable.
Annex DVA Equipment with isolated ground (earthing) No such receptacles. N/A
(G.4.2) receptacles complies with NEC 250.146(D) and
CEC 10-112 and 10-906(8).
Annex DVA Where a fuse is used to provide Class 2 or No such fuse. N/A
(G.4.3) Class 3 current limiting, it is not operator-
accessible unless it is non- interchangeable.
Annex DVA Motor control devices are required for cord- No such equipment. N/A
(G.5.4) connected equipment with a mains-connected
motor if the equipment is rated more than 12 A,
or if the equipment has a nominal voltage rating
greater than 120 V, or if the motor is rated more
than 1/3 hp (locked rotor current over 43 A).
Annex DVA For ITE room applications, equipment with Building-in component. N/A
(Annex M) battery systems capable of supplying 750 VA for
five minutes have a battery disconnect means
that may be connected to the ITE room remote
power-off circuit.
Page 8 of 9 Report No. 4788327671
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex DVA Wiring terminals intended to supply Class 2 No class 2 circuit. N/A
(Q) outputs according to the NEC or CEC Part 1are
marked with the voltage rating and “Class 2” or
equivalent; marking is located adjacent to the
terminals and visible during wiring.
Annex DVB Additional requirements apply for equipment Building-in component. N/A
(1) used for entertainment purposes intended for
installation in general patient care areas of
health care facilities.
Annex DVC Additional requirements apply for equipment Building-in component. N/A
(1) intended for mounting under kitchen cabinets.
Annex DVE Some equipment, components, sub-assemblies Considered. P
(4.1.1) and materials associated with the risk of fire,
electric shock, or personal injury have
component or material ratings in accordance
with the applicable national (U.S. and Canadian)
component or material requirements.
Components required to comply include:
appliance couplers, attachment plugs, battery
back-up systems, battery packs, circuit
breakers, communication circuit accessories,
connectors (used for current interruption of non-
LPS circuits), power supply cords, direct plug-in
equipment, electrochemical capacitor modules
(energy storage modules with ultra-capacitors),
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), ground-fault current
interrupters, interconnecting cables, data
storage equipment, printed wiring, protectors for
communications circuits, receptacles, surge
protective devices, vehicle battery adapters,
wire connectors, and wire and cables.
Annex DVH Equipment for permanent connection to the Building-in component. N/A
mains supply is subjected to additional
requirements.
Annex DVH Wiring methods (terminals, leads, etc.) used for N/A
(DVH.1) the connection of the equipment to the mains
are in accordance with the NEC/CEC.
Annex DVH Terminals for permanent wiring, including N/A
(DVH.3.2) protective earthing terminals, are suitable for
U.S./Canadian wire gauge sizes, rated 125
percent of the equipment rating, and are
specially marked when specified.
Page 9 of 9 Report No. 4788327671
IEC62368_1B - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex DVH Wire binding screws are not permitted to attach N/A
(DVH.3.2) conductors larger than 10 AWG (5.3 mm 2).
Annex DVH Permanently connected equipment is required N/A
(DVH.4) to have a suitable wiring compartment and wire
bending space.
Annex DVJ Equipment connected to a telecommunication Not intended for connection to N/A
(10.6.1 ) and cable distribution networks and supplied telecommunication network.
with an earphone intended to be held against, or
in the ear is required to comply with special
acoustic pressure requirements.
TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements
CB Testing Laboratory:
Testing location/ address............................. : NATOM Corporation
6-10 Higashiohgishima, Kawasaki-ku, Kawasaki-shi,
Kanagawa, 210-0869 Japan
Associated CB Testing Laboratory:
Testing location/ address............................. :
Tested by (name + signature) ...................... : Yuji Chikazawa/
Hirokatsu Kubota
Project Handler
Testing procedure:
SMT/CTF Stage 3 or 4:
Testing location/ address............................. :
Tested by (name + signature) ...................... :
Witnessed by (name + signature)................ :
Approved by (name + signature) ................. :
Supervised by (name + signature) .............. :
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
When differences exist; they shall be identified in the General product information section.
Product Description
Model FETA7000T series are intended to be used in end-product which connected to three phase star
system and delta system.
Model FETA7000ST series are intended to be used in end-product which connected to three phase, four
wire, (3/N/PE) system.
This Switching Power Supply unit has three units of CB certified component Power Supply Units (PS1,
PS2 and PS3).
Output ratings:
Model FETA7000T-48 and FETA7000ST-48: 48Vdc (21.6-52.8Vdc), 148.2A, maximum 7113W
Model FETA7000T-144 and FETA7000ST-144: 144Vdc (64.8-158.4Vdc), 52.0A, maximum 7488W
Adjustment of output voltage range was made via component VR31.
AUX output (CN1, CN2 pin1, 2): 12 Vdc, 0.15 A
Condition of output derating: Depends on model, input voltage and ambient temperature. See Enclosure
Id. 4-01 and 4-02 for details.
Model Differences
All models are identical to each other except for output terminal connection of switching power supplies
(PS1, PS2, PS3), output rating and the following AC power distribution systems.
- FETA7000T-48 and FETA7000T-144: Three-phase, three wire, delta system and star system power
supply connection.
- FETA7000ST-48 and FETA7000ST-144: Three-phase, four wire, (3/N/PE) system power supply
connection.
Technical Considerations
- The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted
by the manufacturer’s specification of: 60 °C (See Enclosure Id. 4-01 and 4-02 for details of output
derating upon the factors including ambient temperature.)
- The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 + A2:2013 (which includes all European national differences, including those
specified in this test report).
- The power supply in this equipment was: Investigated to IEC 60950-1. As part of the investigation of
this product, the power supply and its test report were reviewed and found to comply with IEC 60950-
1.
- Models FETA7000T-48 and FETA7000ST-48 were tested with output voltage range of 21.6 – 52.8Vdc
(maximum 7113W), Models FETA7000T-144 and FETA7000ST-144 were tested with output voltage
range of 64.8 – 158.4Vdc (maximum 7488W), Adjustment was made via component VR31.
- The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-
Ground: 428 Vrms, 976Vpk, Primary-Secondary: 349 Vrms, 1050 Vpk
- The following secondary output circuit are SELV: 48Vdc output of Models FETA7000T-48 and
FETA7000ST-48, and interface circuit (CN1, CN2) of all models.
- The following secondary output circuits are at hazardous energy levels: Outputs of all models (except
for AUX output)
- The following secondary output circuits are limited power source: AUX output
- The power supply terminals and/or connectors are: Suitable for factory wiring only
- Proper bonding to the end-product main protective earthing termination is: Required (Chassis or
Cover)
- Mains Supply Source is assumed to both Delta system and Star system during the tests for model
FETA7000T-48 and FETA7000T-144.
- Mains Supply Source is assumed to Star system during the tests for model FETA7000ST-48 and
FETA7000ST-144.
Additional Information
This report is a reissue of CB report No. 4787682858, CB test certificate No. US-29277-UL.
Base on the previously conducted testing and the review of product technical documentation including
photos, Schematics, wiring diagrams and similar, has been determined that the product continues to
comply with the standard with the following modifications.
Working voltage at inside certified component power supply units and clearance and creepage distances
were additionally assessed in this report due to deviation of mains supply systems.
In this Test Report, CENELEC mark license indicating compliance to EN standard was used to verify
component compliance to IEC standard because the standards are technically equivalent.
For table 1.5.1, UL Standard has requirements that meet or exceed the relevant IEC requirements.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
1 GENERAL P
1.5 Components P
1.5.1 General P
Comply with IEC 60950-1 or relevant component Components, which are found P
standard to affect safety aspects, comply
with the requirements of this
standard or comply with the
safety requirement of the
relevant component standards.
1.5.2 Evaluation and testing of components Components, which are P
certified for IEC and/or national
standards, are used correctly
within their ratings.
Components not covered by
IEC standards are tested under
the conditions present in the
equipment.
1.5.3 Thermal controls Evaluated in certified N/A
component power supply.
1.5.4 Transformers Evaluated in certified N/A
component power supply.
1.5.5 Interconnecting cables No interconnecting cables. N/A
1.5.6 Capacitors bridging insulation Type X2 capacitors are used P
between lines.
Type Y1 capacitors are used
between line and earth comply
with IEC 60384-14 (for model
FETA7000T series).
Type Y1 capacitors are used
between Neutral and FG
comply with IEC 60384-14 (for
model FETA7000ST series).
(see appended table 1.5.1)
1.5.7 Resistors bridging insulation Evaluated in certified N/A
component power supply.
1.5.7.1 Resistors bridging functional, basic or N/A
supplementary insulation
1.5.7.2 Resistors bridging double or reinforced insulation N/A
between a.c. mains and other circuits
1.5.7.3 Resistors bridging double or reinforced insulation N/A
between a.c. mains and antenna or coaxial cable
1.5.8 Components in equipment for IT power systems N/A
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
4 PHYSICAL REQUIREMENTS P
4.1 Stability N/A
Angle of 10 Built-in component. N/A
Test force (N) .........................................................: N/A
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
4.7.1 Reducing the risk of ignition and spread of flame Materials with the required P
flammability classes are used.
Safety relevant components
used within their specified
rating.
Electrical parts are not likely to
ignite nearby materials.
Temperatures see 4.5.2.
Method 1, selection and application of components (see appended table 4.7) P
wiring and materials
Method 2, application of all of simulated fault N/A
condition tests
4.7.2 Conditions for a fire enclosure Built-in component: fire N/A
enclosure is to be provided by
the end product.
4.7.2.1 Parts requiring a fire enclosure N/A
4.7.2.2 Parts not requiring a fire enclosure N/A
4.7.3 Materials P
4.7.3.1 General Materials with the required P
flammability classes are used.
4.7.3.2 Materials for fire enclosures N/A
4.7.3.3 Materials for components and other parts outside N/A
fire enclosures
4.7.3.4 Materials for components and other parts inside fire Internal components except P
enclosures small parts are V-2, HF-2 or
better. Small parts were
mounted on minimum V-1 PWB.
4.7.3.5 Materials for air filter assemblies No air filter assemblies. N/A
4.7.3.6 Materials used in high-voltage components No high voltage (>4 kV) N/A
components.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
A.2 Flammability test for fire enclosures of movable equipment having a total N/A
mass not exceeding 18 kg, and for material and components located inside fire
enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1 Samples, material ................................................. :
Wall thickness (mm) ............................................. :
A.2.2 Conditioning of samples; temperature (°C) ......... : N/A
A.2.3 Mounting of samples ............................................ : N/A
A.2.4 Test flame (see IEC 60695-11-4) N/A
Flame A, B or C ................................................... :
A.2.5 Test procedure N/A
A.2.6 Compliance criteria N/A
Sample 1 burning time (s)..................................... :
Sample 2 burning time (s)..................................... :
Sample 3 burning time (s)..................................... :
A.2.7 Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N/A
Sample 1 burning time (s)..................................... :
Sample 2 burning time (s)..................................... :
Sample 3 burning time (s)..................................... :
A.3 Hot flaming oil test (see 4.6.2) N/A
A.3.1 Mounting of samples N/A
A.3.2 Test procedure N/A
A.3.3 Compliance criterion N/A
B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and N/A
5.3.2)
B.1 General requirements Evaluated in certified N/A
component power supply.
Position .................................................................:
Manufacturer ........................................................:
Type ......................................................................:
Rated values ........................................................:
B.2 Test conditions N/A
B.3 Maximum temperatures N/A
B.4 Running overload test N/A
B.5 Locked-rotor overload test N/A
Test duration (days) ..............................................:
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, N/A
7.3.2, 7.4.3 and Clause G.5)
N.1 ITU-T impulse test generators Not used. N/A
N.2 IEC 60065 impulse test generator N/A
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment N/A
DD.1 General Not rack-mounted equipment. N/A
DD.2 Mechanical strength test, variable N………………..: N/A
DD.3 Mechanical strength test, 250N, including end N/A
stops……………………………………………………:
DD.4 Compliance……………………………………………. N/A
:
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
Switching Power Cosel Co., Ltd. FETA2500BA-48 (PRI/SEC/GND) IEC 60950-1, UL (CB)
Supplies (PS1, Input: 200- IEC 62368-1 (4788327644)
PS2, PS3) 240Vac
50-60Hz 13.8 A UL 60950-1 UL (E132067)
Output: 48Vdc
52A
Secondary Internal Interchangeable Interchangeable (SEC) Minimum UL 758 UL
Wire 80 C, Minimum
300 Vac
Insulation tube Nikkan Industries E-651U-1 Supplementary UL 224 UL (E88468)
Co., Ltd. Insulation,
Silicone rubber,
300V, 200 C
Insulation sheet Sabic Japan L L C FR700 Basic Insulation, UL 94 UL (E207780)
PC, RTI: 130
C,
V-0, 0.25 mm
thick.
Alternate AGC CARBOGLASS Basic Insulation, UL 94 UL (E141248)
Polycarbonate Co., CFR230B PC, RTI: 130
Ltd. C,
V-0, 0.25 mm
thick.
Chassis and Cover -- -- High Cr -- --
stainless
1 mm thick.
PWB Interchangeable Interchangeable V-0, minimum UL 796 UL
130 C
Supplementary information: The CBTL has verified the component information.
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
19.0 19.0
240 19.0, 19.0, 22.7 -- (+) 19.0, 19.0, 60Hz, 52.8V, 134.73A
19.0 19.0
FETA7000 -- -- -- -- -- --
T-144
Power -- -- -- -- -- 3 PHASE, Star System
Source
Connection
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 50 Hz, 144 V, 52 A
24.0 24.0
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 60 Hz, 144 V, 52 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 144 V, 52 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 144 V, 52 A
20.0 20.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 50 Hz, 158.4 V, 47.28 A
24.0 24.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 60 Hz, 158.4 V, 47.28 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 158.4 V, 47.28 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 158.4 V, 47.28 A
20.0 20.0
Power -- -- -- -- -- 3 PHASE, Delta System, Gnd
Source connected to R line.
Connection
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 50 Hz, 144 V, 52 A
24.0 24.0
200 24.5, 24.5, 23.9 -- (+) 24.5, 24.5, 60 Hz, 144 V, 52 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 144 V, 52 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 144 V, 52 A
20.0 20.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 50 Hz, 158.4 V, 47.28 A
24.0 24.0
200 24.0, 24.5, 23.9 -- (+) 24.0, 24.5, 60 Hz, 158.4 V, 47.28 A
24.0 24.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 50 Hz, 158.4 V, 47.28 A
20.0 20.0
240 20.0, 20.0, 23.9 -- (+) 20.0, 20.0, 60 Hz, 158.4 V, 47.28 A
20.0 20.0
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
11.4 11.4
Supplementary information: (+) Branch circuit breaker, Rated 50A.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
supplementary information:
(+) CN2 (CN1) 1pin is connected to Ground.
(2+) For FETA7000T-144 (Maximum voltage within output voltage range: 158.4V, 47.28A)
(3+) CN2 (CN) 1 pin is not connected to Ground (floating).
(4+) Test was conducted three times.
(5+) For PS1 (FETA2500BA-48)
Note: This test was performed to confirm whether the output (non- SELV) of model FETA7000T-144 would
affect interface circuit (SELV). Interface circuits are connected to AUX circuits of the certified component
power supply FETA2500BA-48. Therefore, voltage between CN2 (CN1) 1 pin and 2 pin connected to AUX
circuits was measured as representative. This measurement covers all interface circuits.
Test performed on model FETA7000T-144 representative of model FETA7000ST-144 because secondary
circuits are identical.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
L1 to L2, L2 to L3 of Terminal < 420 < 250 1.5 (1.8) 10.6 2.5 10.6
Block (TB1) (3+)
PWB -- -- -- -- -- --
Trace at between R and S of < 420 < 250 1.5 (1.8) 4.3 2.5 4.3
Terminal Block (TB1) (+)
Trace at between L3 and L2 of < 420 < 250 1.5 (1.8) 5.3 2.5 5.3
Terminal Block (TB1) (3+)
Trace at Capacitors (C13) (+) < 420 < 250 1.5 (1.8) 4.0 2.5 4.0
Trace at between Capacitor < 420 < 250 1.5 (1.8) 5.3 2.5 5.3
(C13) and L2 of Terminal Block
(TB1) (3+)
Trace at between Capacitors < 420 < 250 1.5 (1.8) 3.1 2.5 3.1
(C11, C12) and L2 of Terminal
Block (TB1) (3+)
Trace T to R at Inductor (L11) < 420 < 250 1.5 (1.8) 4.0 2.5 4.0
(+)
Basic/supplementary:
PWB -- -- -- -- -- --
Trace at Capacitor (C14, C16) < 420 < 250 2.0 (2.3) 7.5 2.5 7.5
(+)
Trace at between FG of < 420 < 250 2.0 (2.3) 9.0 2.5 9.0
Terminal Block (TB2) and N of
Terminal Block (TB2) (3+)
Reinforced:
Unit -- -- -- -- -- --
Pri. to Sec.Screw of TR304 to 1050 349 5.8 (6.7) 7.0 7.0 28.0
T301 core (2+)
Pri. to Sec.Wire of Internal fan 1050 349 5.8 (6.7) 15.2 7.0 33.2
to T301 core (2+)
Pri. to Sec.T702 core to output 976 428 5.6 (6.4) 11.1 8.6 13.3
terminal (2+)
Pri. to Sec.TR702 to output 976 428 5.6 (6.4) 10.5 8.6 10.5
terminal (2+)
PWB -- -- -- -- -- --
Pri. to Sec. Trace at between 512 288 4.4 (5.1) 7.0 5.8 7.0
TB211 and TB112 (+)
Pri. to Sec. Trace at between < 420 < 250 4.0 (4.6) 8.5 5.0 8.5
PS1/+V out and L2 of Terminal
Block (TB1) (3+)
Pri. to Sec.Trace at PC204 448 245 4.2 (4.8) 6.2 4.9 6.2
3pin to T301 6, 7, 8pin (2+)
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
Pri. to Sec.Trace at C125 to 440 246 4.2 (4.8) 8.8 5.0 8.8
T301 9, 10, 11pin (2+)
Pri. to Sec.Trace at L311 pin to 728 306 5.0 (5.7) 8.5 6.2 8.5
T301 3, 4, 5pin (2+)
Pri. to Sec.Trace at Optical < 420 < 250 4.0 (4.6) 6.5 4.8 6.5
Isolators (PC201, PC203,
PC204, PC331, PC332) (2+)
Pri. to Sec.Trace at between 408 238 4.0 (4.6) 7.0 4.8 7.0
TR302 and T301 3, 4, 5pin (2+)
Pri. to Sec.Trace at C744 to 496 310 4.4 (5.1) 6.7 6.2 6.7
T701 1pin (2+)
Pri. to Sec. Trace at TR702 to 968 425 5.6 (6.4) 10.0 8.5 10.0
Output terminal trace (2+)
Supplementary information:
(+) FETA7000T-144/-48
(2+) FETA2500BA-48
(3+) FETA7000ST-144/-48
The Value in parentheses of above table is required clearance of operated at up to 3000 m sea level. The
multiplication factors of table A.2 of IEC 60664-1 applied. (1.14 times of required clearance of operated at
up to 2000 m sea level.)
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
Max. -- -- -- -- -- -- -- -- --
current
during
normal
condition
Max. -- -- -- -- -- -- -- -- --
current
during fault
condition
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests P
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
TR491 Short 264Vac 15 (+) 15.0, Output down: 144V, 52A >124V
(C to E) /60Hz minutes 17.0, 52A.
(2+) 15.0 Unit kept the operation aftre short
test.
NB, NC, NT, Ambient: 25 °C
TR491 Short 264Vac 15 (+) 15.0, Output down: 144V, 52A >128V
(E to B) /60Hz minutes 17.0, 52A.
(2+) 15.0 Unit kept the operation aftre short
test.
NB, NC, NT, Ambient: 25 °C
Abnormal -- -- -- -- -- --
Operation
Test
FETA7000T- -- -- -- -- -- --
144
FAN of PS2 Stalled 180 Vac 5 (+) -- After 5 seconds. unit shut down
/60Hz seconds no damaged.
(2+) NB, NC, NT, Ambient: 25 °C
Phase open opened 180 Vac 1 (+) -- Unit shut down no damaged.
(S line) /60Hz second NB, NC, NT, Ambient: 25 °C
(2+)
Phase open opened 180 Vac 1 (+) -- Unit shut down no damaged.
(S line) /60Hz second NB, NC, NT, Ambient: 25 °C
(3+)
Power -- -- -- -- -- --
Supply
output
short- circuit
/overload
Test
FETA7000T- -- -- -- -- -- --
48
52.8V output Short 264 Vac 1 (+) -- Unit shut down no damaged.
/60Hz second NB, NC, NT, Ambient: 25 °C
(2+)
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
52.8V output Overload 264 Vac 7 hours, (+) 22.0, Maximum continuous temperature
/60Hz 21 21.5, was obtained at 52.07V, 173A
(2+) minutes. 22.0 load.
T301 coil (Sec. side) of PS1:
101 °C.
T701 coil of PS1: 81 °C.
T301 coil (Sec. side) of PS2:
107 °C.
T701 coil of PS2: 82 °C.
T301 coil (Sec. side) of PS3:
101 °C.
T701 coil of PS3: 80 °C.
Then temperature decreased
when further loaded over 173 A
load.
NB, NC, NT, Ambient: 25°C
FETA7000T- -- -- -- -- -- --
144
158.4V Short 264 Vac 1 (+) -- Unit shut down no damaged.
output /60Hz seccond NB, NC, NT, Ambient: 25 °C
(2+)
158.4V Overload 264 Vac 4 hours, (+) 22.0, Maximum continuous temperature
output /60Hz 48 22.0, was obtained at 157.6 V, 56.8 A.
(2+) minutes. 22.0 load.
T301 coil (Sec. side) of PS1:
101 °C.
T701 coil of PS1: 81 °C.
T301 coil (Sec. side) of PS2:
108 °C.
T701 coil of PS2: 84 °C.
T301 coil (Sec. side) of PS3:
100 °C.
T701 coil of PS3: 80 °C.
Then temperature decreased
when further loaded over 56.8 A
load.
NB, NC, NT, Ambient: 26 °C
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
(+) Branch circuit breaker, Rated 50A.
(2+) Power Source Connection: 3 PHASE, Delta System,
(3+) Power Source Connection: 3 PHASE, Star System,
CT - Constant temperatures were obtained
NB - No indication of dielectric breakdown after 60 seconds
NC - Cheesecloth remained intact
NT - Tissue paper remained intact
Test performed on models FETA7000T-144 and FETA7000T-48 representative of models FETA7000ST-
144 and FETA7000ST-48 because the difference between each other is only the difference between the
primary part and the supply power source at a level that is not affected by the above test results.
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
T301 1) -- -- -- -- --
Pri. to Sec. Reinforced AC 3000 11.4 11.4 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced AC 3000 -- 2) -- 2) Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
T701 3) -- -- -- -- --
Pri. to Sec. Reinforced AC 3000 12.7 12.7 --
External V
Pri. pin to Core
(Sec.)
Pri. to Sec. Reinforced AC 3000 -- 4) -- 4) Triple
Internal V Insulated
Pri. wire to Sec. wire used.
wire
supplementary information:
1)
Core of Transformer T301 is considered as Sec.
2)
Pri. wire is used Triple Insulation Wire.
3)
Core of Transformer T701 is considered as Pri.
4)
Sec. wire is used Triple Insulation Wire.
Note: The Value in parentheses of above table is required clearance of operated at up to 3000 m sea level.
The multiplication factors of table A.2 of IEC 60664-1 applied. (1.14 times of required clearance of operated
at up to 2000 m sea level.)
This table is for certified power supply: model FETA2500BA-48. But this table was confirmed, because
working voltage of model FETA2500BA-48 increased in combination with 3 PHASE power supply
connection.
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.2.4.1 In Denmark, certain types of Class I appliances (see Built-in component. N/A
3.2.1.1) may be provided with a plug not establishing No power supply cord
earthing conditions when inserted into Danish provided.
socket-outlets.
1.2.13.14 In Norway and Sweden, for requirements see Built-in component. N/A
(A11:2009) 1.7.2.1 and 7.3 of this annex.
Enclosure_1 Page 10 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.5.7.1 In Finland, Norway and Sweden, resistors bridging No such resistor used. N/A
(A11:2009) BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT
TYPE A must comply with the requirements in 1.5.7.1.
In addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.
1.5.8 In Norway, due to the IT power system used (see Built-in component. N/A
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
1.5.9.4 In Finland, Norway and Sweden, the third dashed No such components.. N/A
sentence is applicable only to equipment as defined
in 6.1.2.2 of this annex.
Enclosure_1 Page 11 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.2.1 In Finland, Norway and Sweden, CLASS I Built-in component. N/A
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for
1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
1.7.2.1 In Denmark, CLASS I PLUGGABLE EQUIPMENT Built-in component. N/A
(A2:2013)
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
1.7.5 In Denmark, socket-outlets for providing power to No socket-outlet provided. N/A
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when
used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in
accordance with Standard Sheet DK 1-1b or DK 1-
5a.
1.7.5 For CLASS II EQUIPMENT the socket outlet shall be in
(A11:2009)
accordance with Standard Sheet DKA 1-4a.
Enclosure_1 Page 13 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
1.7.5 In Denmark, socket-outlets for providing power to No socket-outlet provided. N/A
(A2:2013) other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard Sheets
are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception for
STATIONARY EQUIPMENT where the socket-
outlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class
II apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet
DKA 1-4a. Other current rating socket outlets shall
be in compliance with by DS 60884-2-D1
Standard Sheet DKA 1-3a or DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
2.2.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and Built-in component. N/A
6.1.2.2 of this annex.
2.3.2 In Finland, Norway and Sweden there are No TNV circuits. N/A
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
2.3.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and No TNV circuits. N/A
6.1.2.2 of this annex.
2.6.3.3 In the United Kingdom, the current rating of the Considered. P
circuit shall be taken as 13 A, not 16 A.
2.7.1 In the United Kingdom, to protect against excessive Not direct plug-in. N/A
currents and short-circuits in the PRIMARY CIRCUIT
of DIRECT PLUG-IN EQUIPMENT, tests according
to 5.3 shall be conducted, using an external
protective device rated 30 A or 32 A. If these tests
fail, suitable protective devices shall be included as
integral parts of the DIRECT PLUG-IN EQUIPMENT,
so that the requirements of 5.3 are met.
2.10.5.13 In Finland, Norway and Sweden, there are No TNV circuits. N/A
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
3.2.1.1 In Switzerland, supply cords of equipment having a Built-in component. N/A
RATED CURRENT not exceeding 10 A shall be No power supply cord
provided with a plug complying with SEV 1011 or provided.
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15 3P+N+PE
250/400 V, 10 A
Enclosure_1 Page 14 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
SEV 6533-2.1991 Plug Type 11 L+N
250 V, 10 A
SEV 6534-2.1991 Plug Type 12 L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socket-
outlet system is being introduced in Switzerland, the
plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400
V, 16 A
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Denmark, supply cords of single-phase Built-in component. N/A
(A2:2013) equipment having a rated current not exceeding 13
A shall be provided with a plug according to DS No power supply cord
60884-2-D1. provided.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Justification
the Heavy Current Regulations, 6c
3.2.1.1 In Spain, supply cords of single-phase equipment Built-in component. N/A
having a rated current not exceeding 10 A shall be No power supply cord
provided with a plug according to UNE 20315:1994. provided.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules, shall be
provided with a plug in accordance with standard
UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
3.2.1.1 In the United Kingdom, apparatus which is fitted Built-in component. N/A
with a flexible cable or cord and is designed to be No power supply cord
connected to a mains socket conforming to BS 1363 provided.
by means of that flexible cable or cord and plug,
shall be fitted with a ‘standard plug’ in accordance
with Statutory Instrument 1768:1994 - The Plugs and
Sockets etc. (Safety) Regulations 1994, unless
exempted by those regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
Enclosure_1 Page 16 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
3.2.1.1 In Ireland, apparatus which is fitted with a flexible Built-in component. N/A
cable or cord and is designed to be connected to a No power supply cord
mains socket conforming to I.S. 411 by means of provided.
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.
3.2.4 In Switzerland, for requirements see 3.2.1.1 of this N/A
annex.
3.2.5.1 In the United Kingdom, a power supply cord with Built-in component. N/A
conductor of 1,25 mm2 is allowed for equipment with No power supply cord
a rated current over 10 A and up to and including 13 provided.
A.
3.3.4 In the United Kingdom, the range of conductor Built-in component. N/A
sizes of flexible cords to be accepted by terminals No power supply cord
for equipment with a RATED CURRENT of over 10 provided.
A up to and including 13 A is:
• 1,25 mm2 to 1,5 mm2 nominal cross-sectional area.
4.3.6 In the United Kingdom, the torque test is performed Not direct plug-in. N/A
using a socket outlet complying with BS 1363 part
1:1995, including Amendment 1:1997 and
Amendment 2:2003 and the plug part of DIRECT
PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test of 12.17
is performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of clauses
22.2 and 23 also apply.
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is known Not direct plug-in. N/A
as plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 - National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets for
domestic use) Regulations, 1997.
Enclosure_1 Page 17 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
5.1.7.1 In Finland, Norway and Sweden TOUCH Built-in component. N/A
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A
that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation
of that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1 In Finland, Norway and Sweden, add the following No TNV circuits. N/A
(A1:2010)
text between the first and second paragraph of the
compliance clause:
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and in
addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
Enclosure_1 Page 18 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause Requirement + Test Result - Remark Verdict
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Annex ZD
(informative)
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
National Differences --
Appendix Variations to IEC 60950-1, Ed 2.2 (2013) for Australia and New Zealand --
ZZ
1.2 DEFINITIONS P
After definition ‘PERSON, SERVICE’, insert the Added. P
following new definition:
POTENTIAL IGNITION SOURCE…….1.2.12.201
1.5 COMPONENTS P
1.5.1 1. ............................................................. First Added and considered. P
paragraph, insert the following text after the
words ‘IEC component standard:
or the relevant Australian/New Zealand
Standard
2........................................................ In the
Note, insert the following text after the word
standard:
or the relevant Australian/New Zealand
Standard
3........................................................ Second
paragraph, delete the words ‘without further
evaluation’
Enclosure_1 Page 21 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
3. ...........................................................Delete N/A
Footnote a and replace with the following:
a
This nominal cross-sectional area is only allowed for
Class II appliances if the length of the power supply cord,
measured between the point where the cord, or cord
guard, enters the appliance, and the to the plug does
not exceed 2 m (0,5 mm2 three-core supply flexible
cords are not permitted; see AS/NZS 3191)
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
NOTE 202 The 3 kV and 1.5 kV values have been determined N/A
considering the low frequency induced voltages from the power
supply distribution system.
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
1.7.7 Wiring terminals intended to supply Class 2 outputs No such terminals. N/A
in accordance with CEC Part 1 or NEC shall be
marked with the voltage rating and “Class 2” or
equivalent. Marking shall be located adjacent to the
terminals and shall be visible during wiring.
2.5 Where a fuse is used to provide Class 2, Limited No limited power source. N/A
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
2.6 Equipment with isolated ground (earthing) N/A
receptacles are required to comply with NEC
250.146(D) and CEC 10-112 and 10-906(8).
2.7.1 Suitable NEC/CEC branch circuit protection rated at Built-in component. N/A
the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
4.7.3.1 For computer room applications, enclosures with Built-in component. N/A
combustible material measuring greater than 0.9 No such equipment.
m2 (10 sq ft) or a single dimension greater than 1.8
m (6 ft) are required to have a flame spread rating
of 50 or less. For other applications, enclosures
with the same dimensions require a flame spread
rating of 200 or less.
Non-metallic enclosures of equipment for use in N/A
spaces used for environmental air (plenums) are
required to comply
with UL 2043.
Annex H Equipment that produces ionizing radiation is No ionizing radiation. N/A
required to comply with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
Enclosure_1 Page 34 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
OTHER DIFFERENCES
The following key national differences are based on requirements other than national regulatory
requirements.
1.5.1 Some components and materials associated with Considered. P
the risk of fire, electric shock, or personal injury are
required to have component or material ratings in
accordance with the applicable national (Canadian
and/or U.S.) component or material standard
requirements. These components include:
attachment plugs, battery packs (rechargeable type,
used with transportable equipment), cathode ray
tubes, circuit breakers, communication circuit
accessories, connectors (used for current
interruption of non-LPS circuits), cord sets and
power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), fuseholders, ground-fault
current interrupters, industrial control equipment,
insulating tape, interconnecting cables,
lampholders, limit controls, printed wiring, protectors
for communications circuits, receptacles, solid state
controls, supplementary protectors, switches
(including interlock switches), thermal cutoffs,
thermostats, (multi-layer) transformer winding wire,
transient voltage surge suppressors, tubing, wire
connectors, and wire and cables.
1.6.1.2 A circuit for connection to the DC Mains Supply is No DC Mains Supply N/A
classified as either a SELV Circuit, TNV-2 Circuit or connections.
Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage shall include
consideration of the battery charging “float voltage”
associated with the intended supply system,
regardless of the marked power rating of the
equipment.
2.3.1 For TNV-2 and TNV-3 circuits with other than No TNV circuits. N/A
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the maximum acceptable current
through a 2000 ohm resistor (or greater) connected
across the voltage source with other loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal operating conditions.
2.3.2.1 In the event of a single fault between TNV and N/A
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
2.6.2 Equipment with functional earthing is required to be No functional earthing symbol N/A
marked with the functional earthing symbol (IEC used.
60417-6092).
Enclosure_1 Page 35 of 56 Report No. 4788327671
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ATTACHMENT TO TEST REPORT IEC 60950-1 with A1: 2009 and A2:2013
U.S.A. NATIONAL DIFFERENCES
Information technology equipment – Safety – Part 1: General requirements
Differences according to ................ : UL 60950-1-07(Second Edition) + A1: 2011 + A2: 2014
Attachment Form No. ...................... : US_ND_IEC60950_1F
Attachment Originator .................... : UL
Master Attachment .......................... : Date 2014-07
Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
IEC60950_1F - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Copyright © 2017 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
National Differences
1.2.4.1 Add the following new notes. No power cords N/A
provided.
Note: Even if the equipment is designed as Class I, the
equipment is regarded as CLASS 0I EQUIPMENT (see
1.2.4.3A) when 2-pin adaptor with earthing lead wire or cord
set having 2-pin plug with earthing lead wire is provided or
recommended.
1.2.4.3A Add the following new clause. Built-in component. N/A
1.3.2 Add the following notes after the first paragraph: Built-in component. N/A
1.5.2 Add the following Note 2 after the 4th dashed paragraph: No such appliance N/A
coupler.
Note 2 See 1.7.5A when Type C.14 appliance coupler rated
10 A per JIS C 8283-1 is used with an equipment rated not
more than 125 V and rated more than 10 A.
1.5.5 Add the following Note after the last paragraph: No interconnection
cord set.
NOTE An interconnection cord sets provided with
interconnecting coupler for mains supply complying with JIS C
8283-2-2 should comply with JIS C 8286.
1.5.9.1 Add the following in the last of NOTE 1. No such VDR. N/A
1.7.1.2 Replace first and second dashed paragraphs with the Considered. P
followings:
1.7.5A Add the following new clause after 1.7.5. No appliance N/A
coupler.
1.7.5A Power supply cord set
If appliance coupler according to IEC60320-1, C.14(rated
current: 10A) is used in equipment whose rated voltage is less
than 125V and rated current is over 10A, the following
instruction or equivalent shall be described in the operating
instruction.
“ Use only designated cord set attached in this equipment”
Example in Japanese:
1.7.14A Add the following new clause after 1.7.14. Built-in component. N/A
Example in Japanese:
Example in Japanese:
1.7.14B Add the following new clause after 1.7.14A Built-in component. N/A
b) A test with the test finger, Figure 2A, which shall not contact
parts described above when applied to openings in the
ENCLOSURES after removal of parts that can be detached by
an OPERATOR, including fuseholders, and with OPERATOR
access doors and covers open. It is permitted to leave lamps in
place for this test. Connectors that can be separated by an
OPERATOR, other than those complying with JIS C 8303 or
JIS C 8285 or IEC 60309 series or JIS C 8283 series or IEC
60320 series, shall also be tested during disconnection. But
even if the connector does not comply with these standards,
the one having equivalent to or better performance need not be
tested during disconnection.
2.5 Replace “IEC 60730-1” with “JIS C 9730-1” (in item b)). Considered. P
2.6.2 Delete the following line. Built-in component. N/A
2.6.4.2 Replace the first paragraph with the following. Built-in component. N/A
2.6.5.4 Replace the first sentence with the following. Built-in component. N/A
2.10.3.2 In Japan, the value of the main power supply transient voltage
Table 2J for the nominal ac main power supply voltage of 100 V is
determined by applying the row of AC main power supply
voltage 150 V.
2.10.4.3 Replace the 6th paragraph with the following N/A
4.3.4 Add the following after the first sentence: Built-in component. N/A
Annex W Replace the third sentence in the first paragraph with the N/A
W.1 following:
−10 000 cycles of turning the input pin on and off with a
capacitor rated 425 uF ± 10 uF
connected to the input supply while keeping enable active and
shorting the output;
−10 000 cycles of turning the input pin on and off with an
ferrite-core inductor having
350 mH ± 10 mH inductance at 1 kHz and less than 1 Ω d.c.
resistance connected to the
input supply and return while keeping enable active and
shorting the output;
Annex JA
(normative)
Document shredding machines
;
(that use by infants/children may cause a hazard of injury
etc.)
;
(that a hand can be drawn into the mechanical section for
shredding when touching the document-slot)
;
(that clothing can be drawn into the mechanical section for
shredding when touching the document-slot)
;
(that hairs can be drawn into the mechanical section for
shredding when touching the document-slot)
- in case of equipment incorporating a commutator motor,
N/A
N/A
Enclosures
Photographs ID 1-01
Enclosure_2
Page 3 of 29 Report No. 4788327671
Photographs ID 1-02
Enclosure_2
Page 4 of 29 Report No. 4788327671
Photographs ID 1-03
Enclosure_2
Page 5 of 29 Report No. 4788327671
Photographs ID 1-04
Enclosure_2
Page 6 of 29 Report No. 4788327671
Photographs ID 1-05
Enclosure_2
Page 7 of 29 Report No. 4788327671
Photographs ID 1-06
Enclosure_2
Page 8 of 29 Report No. 4788327671
Diagrams ID 2-01
Enclosure_2
Page 9 of 29 Report No. 4788327671
Diagrams ID 2-01
Enclosure_2
Page 24 of 29 Report No. 4788327671
Miscellaneous ID 4-01
Enclosure_2
Page 25 of 29 Report No. 4788327671
Miscellaneous ID 4-02
Enclosure_2
Page 28 of 29 Report No. 4788327671
Miscellaneous ID 5-03
Enclosure_2
Page 29 of 29 Report No. 4788327671
Miscellaneous ID 5-04