03 2.1 Excavator Maintenance.

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 59

Excavator Maintenance

Pre-service =
MAINTENANCE ?

※ The R220LC-9(S) is mainly mentioned in this guide book.

HHI Training Center page 0


※ Precaution and Proper Maintenance instructions

(1) Start to maintenance after you have the full knowledge of the machine.

(2) Use genuine parts(If not, HHI will not reimburse for the failed parts arising from

the wrong use of maintenance check item).

(3) Use the recommended oil.

(4) Remove the dust or water around the inlet of oil tank before supplying oil.

(5) Drain oil when the temperature of oil is warm.

(6) Do not repair anything while operating the Engine. Stop the engine when you fill

the oil.

(7) Relieve hydraulic system of the pressure before repairing the hydraulic system.

(8) Confirm if the cluster is in the normal condition after completion of service.

(9) For more detail information of maintenance, please contact local Hyundai dealer.

HHI Training Center page 1


※ Periodical replacement of safety parts
; The following parts are recommended to replace periodically for using the machine
safely for a long time.

HHI Training Center page 2


1) Fuel hose 2) Heater hose

3) Pump Suction and Delivery hose 4) Boom,Arm and Bucket cylinder line hose

HHI Training Center page 3


1. Spec. of Fuel, Coolant and Lubricants

HHI Training Center page 4


Note] 1. Long life Hyd. Oil(5,000hrs) application on HYUNDAI Excavator, Wheel Loader and Forklift.
1) VG 46 type : From Oct. 2008 ~ 2) VG 68 type : From Oct. 2009 ~
☞ One can see the life of Hyd. oil at the Decal in Cabin.
HHI Training Center page 5
2. Maintenance Chart

HHI Training Center page 6


Note

* Visual check :
1. Bolt Loosening
2. Leakage
3. Narrowness / Wear
4. Cleaning: Radiator,
Cooler…

Rev]Every 250hr

* Air cleaner(Heavy
dusty Air condition)
1) Check : Everyday
2) Clean : Max. 4 Times
3) Replacement :
Every 250Hrs at least.

HHI Training Center page 7


☞ See Note 2.

* Recommendation:
1,000Hrs(Normal Air condition)
Note] 1.

2. Hyd. oil change guide for


machine use of breaker.

HHI Training Center page 8


Note] 3. 9S-Series, Improvement of Pin&Bushing
① Improve Noise and Durability by Reducing The Gap

Assembling Gap
Group Remark
Before After

② ③ A 1 mm 0.5 mm
B 2 mm 1 mm
A: Boom + Upper, Boom + Arm
B: Except Cyl’Installation (However, Boom Cyl’Rod
& Arm Cyl’Rod : 2mm)
② Apply Sintering Bush
- Improve Lubrication and Wear-Resistance
⑤ ⑥ (Injection Period : 50hr  250hr)
③ Apply Polymer Shim : Improve Lubrication

④ Apply Wear-Resistant Cover Plate At Arm End


- Improve Wear-Resistance of The Side of Arm
⑤ Improve Wear-Resistance by Increase of
Hardness of Bucket Boss
- Material Change and Add Heat Treatment
(SM50A  S45C)
- Hardness : HB140  HB240
⑥ Add Reinforce Plate To Control Link
- Improve Strength
- Prevent Link Deformation

HHI Training Center page 9


3. MAINTENANCE Instruction

HHI Training Center page 10


R1200LC-9

1-1) E/G Oil consumption review

Model R800LC-9 R1200-9 Note

Engine Model QSX15 QSK23

Power 510HP 760HP

Oil tank capacity 45.4ℓ 70.0ℓ


Oil Q’ty
9.4ℓ(45.4-36) 14ℓ(70-56)
(between Low and High)
Fuel Consumption 52.7ℓ/H 78.32ℓ/H S Mode

0.135ℓ/H 0.55ℓ/H Acceptable

Eng’ Oil Consumption 0.10∼0.25% Normal

2.7ℓ/20H 11ℓ/20H Per 1 day

3.5days(9.4÷2.7) 1.3days(14÷11) Acceptable


Running Time without filling
Eng’ Oil 3.6days(9.4/2.6) 3.5days(14/4) Normal

※ Caution! One can meet Oil pressure low error or worst E/G trouble just in one week.

HHI Training Center page 11


1-2) Causes of excessive E/G Oil consumption

(1) Piston Ring and Cylinder Liner wear


(2) Horsepower output(Load Factor)
- E/G Oil Consumption depends strongly on horsepower output.
(3) High E/G temperature
- Overheating causes increase of Piston and E/G Oil temperature result in faster degradation
of E/G Oil level and accumulation of carbon deposit on piston.
As a rule of Thumb, every 11℃ increasing of temperature the chemical reaction rate goes
double which produce deposits.
(4) Improper Piston ring assembly

HHI Training Center page 12


HHI Training Center page 13
HHI Training Center page 14
HHI Training Center page 15
3)

Wing
Outer Nut
Element

Inner Element
HHI Training Center page 16
3-1) T/Shooting Case : Imitated Air filter / out of maintenance period problem

Model R210LC-7 Serial 9484 Working Hours 2,509 Hours

Work
Dealer - Dump Delivery date 2008.12.20
condition

Damaged
(1) Symptom section
- Not possible to Engine start (Dark exhaust gas when cranking).

(2) Check Ruined Pad


ⓐ Air Cleaner inspection
- Imitation Air Cleaner. Primary filter was damaged.
- Filter pad was ruined (torn).
ⓑ Engine Oil was polluted severely.
- Engine Oil Level is low.
ⓒ Engine Head inspection : Piston & Ring are all worn out.

(Imitated Air Cleaner)


(3) Service action
- Engine Overhaul.

HHI Training Center page 17


(4) Imitational filters - Poor quality

HHI Training Center page 18


R210LC-9, R380LC-9(S),R450LC-9(s) and up
3-2) Oil washed Air cleaner(Option)
Applied Model] R210LC-9(S)&Bigger model than R380LC-9(S)

Application]

※ HHI option code: EY12

HHI Training Center page 19


(1) Composition

(Filter
including)

HHI Training Center page 20


(2) Service instruction

HHI Training Center page 21


(3) Test result

HHI Training Center page 22


4)

HHI Training Center page 23


5)

HHI Training Center page 24


6)

HHI Training Center page 25


HHI Training Center page 26
HHI Training Center page 27
7)

HHI Training Center page 28


Note] 1. Service interval change when work with Breaker

A. Hyd.oil change guide for the average operating rate

B. Service interval

※ Replace the following filters at one time.

HHI Training Center page 29


2. Maintenance trouble case
1/2

Model R210LC-7 Serial No. #8,022 Hour meter 2,195 Hours

Work
Dealer AGCO Breaker Delivery date 2008.07.30
classification

1) Symptoms
- Every attachment doesn’t work(Main pump not work).
- Hyd. oil color is dark.

2) Checks
ⓐ Disassembly of the Main pump
- Piston Shoe (1ea) missing.
- Excessive rear of Piston shoe.
ⓑ Hyd. tank inspection (Damaged Main pump)
- Sticky polluted(dark colored) oil on the Return filter
(and on the bottom of the tank).

3) Remedy
- Main Pump Assy’ replacement and hyd tank cleaning.

HHI Training Center page 30


2/2
4) Remarks (Pictures for the damaged Main pump and polluted Return filter)

(Polluted Return filter)


(Damaged Piston Shoe)

5) The reason why sticky oil is in the hyd. tank


- Muddy cloud inflow to the Tank through the Breaker.
- Muddy cloud and pollutant got into the Hyd. System in hot temperature, and so the sticky oil is piled up
on the bottom of the tank.

HHI Training Center page 31


3. Long life Hyd.oil

A. Effect of the Long life Hyd.oil use

Wrong use of Hyd.oil] Normal hyd. oil use – rare case] Long life hyd. oil use]
: Wear prevention additive is not : Poor environment and hard work : Normal more than 5,000 hrs.
included in the Oil. condition(w. high temperature).

B. P/No(Long life Hyd. oil) C. Normal Hyd. oil characteristic


Long life hyd. Oil Remark Flashing Liquidity
Viscosity Viscosity Temp.
(VG 46) Temp.
Index
91EE-61440 20 Litter
P/No.
91EE-61420 200 Litter


HHI Training Center page 32
8)

HHI Training Center page 33


9)

10)

HHI Training Center page 34


11)

Hyd. oil

Gear oil

11-1)

Grease

HHI Training Center page 35


11-2)

12)

HHI Training Center page 36


13)

HHI Training Center page 37


14)

드레인 플러그

15)

HHI Training Center page 38


16)

HHI Training Center page 39


17)

HHI Training Center page 40


HHI Training Center page 41
18)

☞ see note (Auto-Grease).

HHI Training Center page 42


HHI Training Center page 43
Note] Auto-Grease

(Model : EP-1, for R800LC-7A/Wheel Loader)

(Model : EBP-2000S, for R800LC-9/R1200LC-9)

HHI Training Center page 44


1) Control unit – Control of Grease filling and pause period

(1) Open the control panel cover with a ‘+’driver.

※ Be careful the Over-torque

(2) Adjust the Grease supply timing with a ‘-’driver.

Pause period
Grease Filling period

•Grease filling cycle increase : Adjust clock-wise.


*Grease filling cycle Decrease : Adjust counter clock-wise

HHI Training Center page 45


① Used for Additional Grease pumping or control
system check.
② Pushing one time: Greasing once for 16 minutes.

Pause time

A. Lubricating period setting Dial

B. Pause period setting Dial

HHI Training Center page 46


2) Indication of LEDs

HHI Training Center page 47


3) Lubrication circuit
(1) Lubrication spots

HHI Training Center page 48


(2) Lubrication circuit

HHI Training Center page 49


Bolt Spring washer

D1 Allotter
D0 Allotter

Spring washer

Protection Cover
Bolt

(D2 Allotter-Bucket link)


(D0,D1 Allotter)

(D3 Allotter) (D4 Allotter)

HHI Training Center page 50


4) Installation and Test
(1) Grease filling(through the Grease nipple with Grease gun)
* To the Grease Pump

Grease nipple

※ Fill the Grease while it be leaked through


the Grease vent.
* Capacity : 8Kg
Grease vent
Grease Tank

Grease nipple

HHI Training Center page 51


(2) Filling through the filling press port

Filling press port

!!! When Grease filling is not sufficient at some grease spots, fill the Grease to
the Allotter directly by hand.

HHI Training Center page 52


T/Shooting case] Reamed hall of Arm+Bucket bushing
1/3

Model R800LC-7A Serial No. #0021 Hour meter 2,565 Hours

User SBS Work condition Construction Delivery Date 2009.06.08

1. Symptoms
(1) Severe working noise on the Bucket
(2) Bucket linkage check
- Arm Bushing hole is reamed so much.

2. Check
(1) Auto Grease System
- Grease Nipple trouble on the Boom : Grease leak
- Grease leak at the end of Arm : Grease Nipple is modified by user
- Grease Nipple trouble on the distributor for Swing Bearing. Grease leak

3. Cause (Arm Bushing hole wear)


: Grease Nipple is modified by user → Grease leak → Lack of lubrication

HHI Training Center page 53


D3

D0

(Grease leakage)

D1

(Modified Nipple) (Trouble on Grease nipple)

HHI Training Center page 54


5) Troubleshooting

HHI Training Center page 55


4. When required Maintenance item

1) Air Conditioner Filter

Full out

(After filter
separation)

HHI Training Center page 56


2) Pilot Pump Relief Valve Screen Filter

View

(Screen filter for relief v/v)

HHI Training Center page 57


3) Last Guard Filter

P-포트

HHI Training Center page 58

You might also like