MOTOR DETAIL PUMP DETAIL SOLAR PANEL INPUT


CONTROLLER DETAIL
TYPE HP RATED STAGE SHUT OFF MFG VOLTAGE POWER
DC 2 160V 3300RPM 15 80 NORYL 222 V 1800 W SEA
PHASE DC_2HP FREQUENCY TESTING ON
KORA 4.5/15ST_B DATE : 23-06-2022
3-PHASE SOLARTIVE_DESIGN 110HZ 40M,50M & 60M

AC
DC Volt DC Current DC Power AC Volt AC Current AC Power Discharge Head Irradiation
SrNo Frequency
(V) (A) (W) (V) (A) (W) (Hz) (LPM) (M) (W/m2)
1 222.82 7.899 1760 115.19 8.552 1692.7 87.577 130 0 1000
2 222.89 7.903 1761 114.9 8.583 1693.6 87.225 85.9 40 1000
3 220.95 7.164 1582 110.72 8.016 1523 84.232 78.7 40 900
4 217.12 6.481 1407 106.17 7.437 1354 81.133 70 40 800
5 212.35 5.791 1229 101.42 6.826 1185.3 77.786 60.8 40 700
6 208.86 5.038 1052 96.24 6.16 1012.4 74.193 48.9 40 600
7 209.07 4.1 857 89.86 5.386 827.8 70.06 34.4 40 500
8 205.25 3.259 668 84.5 4.488 646.2 66.696 17.3 40 400
9 204.95 2.117 433 75.6 3.273 418.9 60.881 0 40 300
MOTOR DETAIL PUMP DETAIL SOLAR PANEL INPUT
CONTROLLER DETAIL
TYPE HP RATED STAGE SHUT OFF MFG VOLTAGE POWER
DC 2 160V 3300RPM 15 80 NORYL 222 V 1800 W SEA
PHASE DC_2HP FREQUENCY TESTING ON
KORA 4.5/15ST_B DATE : 23-06-2022
3-PHASE SOLARTIVE_DESIGN 110HZ 40M,50M & 60M
AC
DC Volt DC Current DC Power AC Volt AC Current AC Power Discharge Head Irradiation
SrNo Frequency
(V) (A) (W) (V) (A) (W) (Hz) (LPM) (M) (W/m2)
1 226.37 7.751 1754 115.27 8.506 1686 87.599 70 50 1000
2 221.22 7.158 1583 111.36 7.958 1521.9 84.89 62.6 50 900
3 221.3 6.308 1395 106.84 7.32 1341.9 81.779 52.8 50 800
4 218.72 5.55 1213 102.07 6.667 1167.4 78.601 42.4 50 700
5 208.13 5.063 1053 98.07 6.049 1015.8 76.087 31 50 600
6 207.73 4.16 864 94.18 5.186 834.7 73.946 16 50 500
7 206.19 3.223 664 89.38 4.212 641.6 71.29 0 50 400

MOTOR DETAIL PUMP DETAIL SOLAR PANEL INPUT


CONTROLLER DETAIL
TYPE HP RATED STAGE SHUT OFF MFG VOLTAGE POWER
DC 2 160V 3300RPM 15 80 NORYL 222 V 1800 W SEA
PHASE DC_2HP FREQUENCY TESTING ON
KORA 4.5/15ST_B DATE : 23-06-2022
3-PHASE SOLARTIVE_DESIGN 110HZ 40M,50M & 60M
AC
DC Volt DC Current DC Power AC Volt AC Current AC Power Discharge Head Irradiation
SrNo Frequency
(V) (A) (W) (V) (A) (W) (Hz) (LPM) (M) (W/m2)
1 218.87 7.978 1746 115.71 8.291 1645.4 87.938 54.6 60 1000
2 218.43 7.244 1582 111.51 7.848 1515 86.044 47.4 60 900
3 217.15 6.464 1403 109 7.237 1349 83.583 38.4 60 800
4 211.04 5.85 1234 104.93 6.599 1188.9 81.462 28.4 60 700
5 210.97 4.975 1049 102.28 5.761 1011.1 80.327 14.9 60 600
6 209.4 4.102 858 98.7 4.912 830.2 78.499 0 60 500