Professional Documents
Culture Documents
Dw3605 T Abcd Cal Davit 01 Rev.1 Design Input
Dw3605 T Abcd Cal Davit 01 Rev.1 Design Input
Dw3605 T Abcd Cal Davit 01 Rev.1 Design Input
DESIGN VERIFICATION:
1. GENERAL LAYOUT
2. DESIGN INPUT
3. DESIGN REPORT
4. ANCHOR DESIGN
1. GENERAL LAYOUT
2. INPUT
2.1. INTRODUCTION
The project deals with the construction of Davit system at varies level in the Project of Artesia Mid Rise
Building (G+28) on plot No. 676-5408 (E006) Tower ‘A’ , ‘B’ , ‘C’ , ‘D’ in Dubai at UAE. Davit system fixed on
the concrete on the anchor bolts. There are different reach of davit in varies level and calculation prepared
for maximum reach of Davit.
2.4. LOADINGS
Dead load are calculated on the basis of unit weight of material specified for construction or based on
the unit weight of materials as per the design criteria
2.4.1 Dead Load (DL)
Total Suspended Load (TSL) = RL + SWP + Mwr + Mc (BS EN 1808:1999 clauses 6.5.2.1 (8)
Rated Load RL = Mp + Me + Mm = (2 x 80) + (2 x 40) + 0 = 240 (BS EN 1808:1999 clauses 6.3.2.1 (2)
Mass of Plat form (SWP) = 280 Kg (Ref. shop drawing)
Mass of wire ropes ( Mwr) = 0.25 Kg / m (Ref. supporting document)
= (Number of wire ropes x Ht. of suspension point )
Wind Pressure (q) = Guided platform 250 N/m 2 (BS EN 1808:1999 clauses 6.3.3, Table 6)
Wind Load on Davit at wire rope point = Area of Platform x Wind Pressure
= 2 m2 x 250 N/m2
= 500 N, 0.5 kN
2.4.4 Combination Load
1DL + 1WL
1.4DL + 1.4WL
Design and Analysis done by Staad Pro and excel spread sheets.