PATIENT DETAILS
VI-SCAN CENTER Vi-Scan (VIJAYAPURA) Date: 13th JUNE, 2022
PATIENT NAME Mrs DANAMMA ZALAKI Age: 46 Sex: FEMALE
REFERRED BY Dr. RAVI S
PURPOSE IMPLANT PLANNING

SCAN DETAILS
Voxel: 160µm Slice Thickness: 160µm Inter-slice Distance: 1 mm
Area of Interest 16
Remarks on Scan Optimal Quality

RADIOGRAPHIC FINDINGS

Evaluation of maxillary dento-alveolar arch:

Teeth missing 16
Root stumps/grossly destructed -
Endodontically treated 13
Fixed partial prosthesis -
Periodontally compromised -

Anatomical considerations:

 Minimal muco-periosteal thickening of the floor of the right maxillary sinus noted.
The cortication of the maxillary sinus walls intact. No interfering septation within.

MOST HEIG
TOOT REPRESENTATIV HT* WIDTH BONE ANY SPECIFIC
H NO E SECTION (in (in mm) TYPE** FINDINGS/COMMENTS
(SUBJECTIVE) mm)

11 3 4.5 D3 Deficient height of bone

*In maxillary arch: Height close/up to floor of the nasal cavity and/or maxillary sinus.

VI-SCAN DIAGNOSTICS
Chesa Helpline - 9606980274 | vi.scan@chesadentalcare.com
NEW DELHI | MUMBAI | KALYAN | PUNE | NASHIK | CHENNAI | MADURAI | HASSAN | BANGALORE | SHIVAMOGGA
Powered By Chesa Dental Care
*In mandibular arch: Height close/up to inferior alveolar canal/incisive canal/closest vital
structure.

OTHER FINDINGS

 Generalised mild interdental crestal bone loss


 Breach in the mesial enamel surface of 15 noted with rarefaction involving dentin
suggestive of dental caries. To be correlated clinically.
 Endodontically treated 13.

RADIOGRAPHIC DIAGNOSIS

 MAXILLARY EDENTULOUS SITE 16 WITH HEIGHT, WIDTH AND


LENGTH OF AVAILABLE BONE AS DESCRIBED.

Dear Doctor – Kindly ensure to correlate our report with your clinical findings.

Thank you for the referral of this patient and the opportunity to serve your practice.

SIGNATURE

REPORTED BY DR. JIGNA V RAJA


CREDENTIALS MDS, DENTO-MAXILLOFACIAL RADIOLOGY
CENTER Vi-Scan (VIJAYAPURA)

(CBCT is an adjunct to clinical observations, not replacement. Practitioner is advised to create his own
workup using viewing software. Dimensions are indicative & may vary according to plane of slicing. 3D
images are for visualization only and are not identical to actual anatomy. Consultative report only, not
valid for medico-legal purpose. We take no responsibility/liability for any untoward incident arising from
the scan data. Artefacts may affect accuracy of measurements in the scanned data.)

VI-SCAN DIAGNOSTICS
Chesa Helpline - 9606980274 | vi.scan@chesadentalcare.com
NEW DELHI | MUMBAI | KALYAN | PUNE | NASHIK | CHENNAI | MADURAI | HASSAN | BANGALORE | SHIVAMOGGA