Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

September 6, 2008 Version : D

CMX-7-E
Intelligent Relay/ Monitor Module
Section: Intelligent/ Addressable Devices

General
The CMX-7-E Monitor Module is a compact addressable
module which contains one relay output and one monitor
input. These two input and output points can work
independently. The relay output is to activate devices,
while the monitor input is to supervise status feedback
from the contact devices.
Features
y Full analog supervision.
y Locking output drive circuit.
y Excellent tamper-resistance ( EMF/RFI ).
y SEMS screws for ease of wiring.
CMX-7-E Intelligent Relay/ Monitor Module
y Occupies two module addresses, the base address N for
relay output and N+1 for monitor input.
y LED flashes during normal operation and latches steady will be N and the encoder will not assign its input
to indicate alarm. LED light is programmable to be off, address.
flashing, or latches steady. Wiring
Specification y T1 ( – )、T2 ( + ) : Loop communication bus
y Operating Voltage : 15 ~ 32VDC y T4、T5 : CBE contact output ( NO )
y Operating Temperature : -10 ~ 50 ºC y T3 : N/A
y Relative Humidity : 10% ~ 95%RH, non-condensing y T6、T7 : CBE contact output ( NC )
y Relay Contact Current (Resistive) : y T8、T9 : Passive supervising devices input
- 2A@30VDC
- 1A@125VAC Wiring Diagram
y Dimensions : 120mm (Height) × 105mm (Width)
Application
Loop
Under normal circumstances, the CMX-7-E monitor Bus
module occupies two consecutive addresses, N as the CBE
output address and N+1 as the supervision input address.
The encoder sets the module address to N, and the address
Mounting
N+1 will be assigned automatically. The CMX-7-E monitor module can be
If no supervision input is required, short T8 and T9 before mounted directly to a 50 to 100 mm
and only when addressing. The module output address junction box as shown in the
NOTIFIER® is registered trademark of Honeywell
will Mounting Diagram.
International Inc.
©2006 Honeywell International Inc. All rights reserved.
Unauthorized use of this document is strictly prohibited. Mounting Diagram
This document is not intended to be used for installation purposes. We try to keep our product
information up-to-date and accurate. We cannot cover all specific applications or anticipate all
requirements. All specifications are subject to change without notice. For more information, please
contact NOTIFIER. Phone: +886 (2) 22487171 Fax: +886 (2) 22450927

Page 1 of 1 – CMX-7-E Rev. D • 9/6/08