Engineering Specifications

Title: Page: No.:


2007 TLB VCM Specification 1 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

APPENDIX 4: FAILURE MESSAGES DETAILS / WARNINGS


As a general rule:

During cranking all the warning detection activities have to be stopped (SEE APPENDIX 4)
Each warning based on a can message shall be activated if the message is received for three times in a
row and only if the value contained into relevant message is valid (that means not FFFE or FFFF).
Each warning based on a direct input should be filtered as per the diagram below indicated unless
specified differently. The de-activation timer does not correspond to the visualization of a specific
warning. If there is an error code active relevant to a specific sensor, all the warnings related to that
sensor has to be deactivated.
For all those warnings which are activated upon the engine speed presence, whenever the Engine speed
value (either direct reading or CAN message) is not correct, the Engine oil pressure value has to be used
as a reference.
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 2 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
WARNING ACTIVATION UPON SWITCH/SENSOR INPUT DETECTION
Switch
/Sensor
commutation
for
warning
condition
t
Time
trigger
for
warning
activation
counter
t

Warning
activation

t
1sec
debounce

debounce

5 sec
activation de -activation
filter filter

Switch
/Sensor
commutation
for
warning
condition
t
Time
trigger
for
warning
activation
counter
t
Warning
activation

t
t<5 sec t<5 sec 5 sec
debounce

debounce

debounce

debounce

debounce

counter counter warning


reset reset active

NOTE: Counter needs to be reset to 0 all the times the reading of a switch/sensor goes to 0
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 3 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
In the following tables, the features of each warning are described:
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Engine Coolant 1002 VCM Coolant temp 1 Red
coolant above signal –
Continuous
too high 112°C for Above
5 sec. Normal
Engine oil Pressure 3028 ECU Oil pressure 1 Red
pressure < 37.7 sensor –
Continuous
too low psi pressure too
rpm>500 low
Transmiss Continuous Switch 1008 VCM The engine 1 Red
ion oil C1-25 must be
pressure closed to running with
too low ground switch closed
for 25 for 25
seconds seconds
CAN Continuous DTC for 3334 ECU Timeout of 1 Red
malfunction
200 ms CAN message
TCS1 Speed
CAN Continuous DTC for 3339 ECU Timeout of 1 Red
malfunction
200 ms CAN message
TCS1 Torque
CAN Continuous 5 1051 VCM Timeout of 1 Red
malfunction
seconds CAN message
without EEC1
message
CAN Continuous 5 sec. 1052 VCM Timeout of 1 Red
malfunction
without CAN message
message EEC3
CAN Continuous 25 sec. 1053 VCM Timeout of 1 Red
malfunction
without CAN message
message CNFBAM

CAN Continuous 5 sec. 1054 VCM Timeout of 1 Red


malfunction
without CAN message
message Engine
Temperature
CAN Continuous 5 sec. 1055 VCM Timeout of 1 Red
malfunction
without CAN message
message Inlet/Exhaust
CAN 5 sec. 1056 VCM Timeout of 1 Red
malfunction
without CAN message
Continuous
message Engine Fluid
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 4 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
CAN 5 sec. 1057 VCM Timeout of 1 Red
malfunction
without CAN message
Continuous
message Vehicle
Electrical
CAN Continuous 5 sec. 1058 VCM Timeout of 1 Red
malfunction
without CAN message
message EDC2BC

CAN Continuous 5 sec. 1059 VCM Timeout of 1 Red


malfunction
without CAN message
message DM1

Trans. oil Continuous Trans Oil 1009 VCM Transmission 1 Red


temperature
above oil
too high
115°C for temperature
5 sec. limit reached
General Continuous DTC’s Only display 1 Red
DM1 3000 – with DM1
message 3366 request

One N/A VCM 1 Red


Touch
Idle
Active
Park Continuous, Switch N/A VCM This prevents 2 Red
if vehicle is
brake C1-18 park brake
in gear
engaged closed to damage
ground
Brake Continuous Sender 1006 VCM Warns 2 Red
temp too temp customer
high over before brake
152° C fade
for 5 sec.
Brake Continuous Switch 1007 VCM 2 Red
fluid level C1-9
low closed to
Vbat for
5 sec.
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 5 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Engine oil Continuous Pressure 3032 ECU 2 Red
pressure depends
too high on speed
Battery 3051 ECU Battery 2 Red
Charge
voltage to
voltage too Continuous
high ECM too high

Battery Continuous VCM 1014 VCM VCM battery 2 Red


Charge
source voltage
voltage too
high above 16 above 16
volts for volts
5 sec.
Battery Continuous 3052 ECU Battery 2 Red
Charge
voltage to
voltage too
low ECM too low

Battery Continuous VCM 1015 VCM VCM battery 2 Red


Charge
source voltage below
voltage too
low below 11 11 volts
volts for
5 sec.
Alternator Continuous Alternator 1050 VCM Alternator 2 Red
not able to L+ terminal
unable to
charge under 1.5
volts for 5 charge
sec.
Foot One second IVS not 1010 VCM Foot throttle 2 Amber
Throttle alarm every
changing sensor – not
signal out of 30 seconds
range state in plausible
300 ms
Foot One second Throttle 1011 VCM Foot throttle 2 Amber
Throttle alarm every
above sensor –
signal out of 30 seconds
range 4.75 volts signal above
for 5 sec. range
Foot One second Throttle 1012 VCM Foot throttle 2 Amber
Throttle alarm every
below sensor –
signal out of 30 seconds
range 0.25 volts signal below
for 5 sec. range
Foot One second 1013 VCM Foot throttle 2 Amber
Throttle alarm every
sensor – no
signal out of 30 seconds
range signal
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 6 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Foot One second Voltage 1029 VCM Foot throttle 2 Amber
Throttle alarm every
over 9 sensor –
signal out of 30 seconds
range volts for shorted high
5 sec. to Vbat
Foot One second Voltage 1030 VCM Foot throttle 2 Amber
Throttle alarm every
under 0.5 sensor –
signal out of 30 seconds
range volts for shorted low
5 sec. to ground
Foot One second Voltage 1023 VCM Foot throttle 2 Amber
alarm every
throttle over supply
30 seconds
5 volt 5.1 volts voltage too
supply for 5 sec. high
Foot One second Voltage 1024 VCM Foot throttle 2 Amber
alarm every
throttle under 4.9 supply
30 seconds
5 volt volts for voltage too
supply 5 sec. low
Foot One second Voltage 1025 VCM Foot throttle 2 Amber
alarm every
throttle over 9 supply
30 seconds
5 volt volts for shorted high
supply 5 sec. to Vbat
Foot One second Voltage 1026 VCM Foot throttle 2 Amber
alarm every
throttle under 0.5 supply
30 seconds
5 volt volts for shorted low
supply 5 sec. to ground
Hand One second Throttle 1035 VCM Hand throttle 2 Amber
Throttle alarm every
above sensor –
signal out of 30 seconds
range 4.75 volts signal above
for 5 sec. range
Hand One second Throttle 1036 VCM Hand throttle 2 Amber
Throttle alarm every
below sensor –
signal out of 30 seconds
range 0.25 volts signal above
for 5 sec. range
Hand One second 1037 VCM Hand throttle 2 Amber
Throttle alarm every
sensor – no
signal out of 30 seconds
range signal

Hand One second Voltage 1038 VCM Hand throttle 2 Amber


Throttle alarm every
over 9 sensor –
signal out of 30 seconds
range volts for shorted high
5 sec. to Vbat
Hand One second Voltage 1039 VCM Hand throttle 2 Amber
Throttle alarm every
under 0.5 sensor –
signal out of 30 seconds
range volts for shorted low
5 sec. to ground
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 7 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Hand One second Voltage 1031 VCM Hand throttle 2 Amber
alarm every
throttle over supply
30 seconds
5 volt 5.1 volts voltage too
supply for 5 sec. high
Hand One second Voltage 1032 VCM Hand throttle 2 Amber
alarm every
throttle under 4.9 supply
30 seconds
5 volt volts voltage too
supply For 5 sec. low
Hand One second Voltage 1033 VCM Hand throttle 2 Amber
alarm every
throttle over 9 supply
30 seconds
5 volt volts for shorted high
supply 5 sec.
Hand One second Voltage 1034 VCM Foot throttle 2 Amber
alarm every
throttle under 0.5 supply
30 seconds
5 volt volts for shorted low
supply 5 sec.
Seat not in Continuous Switch N/A VCM This must 2 Amber
driving
C1-19 have a
position
closed to debounce
ground time of less
with then 500 ms
vehicle in
gear and
no park
brake
Boost Air One second Boost 1018 VCM Engine over 3 Amber
alarm every
temp too temp operating
30 seconds
high over boost air
88° C for temp
5 sec.
Engine One second Coolant 1019 VCM Engine over 3 Amber
alarm every
coolant above operating
30 seconds
too high 106° C coolant temp
for 5 sec.
Engine One second 3007 ECU Coolant temp 3 Amber
alarm every
coolant signal source
30 seconds
too high high
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 8 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Trans. Oil One second Coolant 1020 VCM Trans over 3 Amber
alarm every
above above operating
30 seconds
105° C 105° C temperature
for 5 sec.
Fuel One second Fuel over 1021 VCM Fuel over 3 Amber
alarm every
Temp. 82° C for operating
30 seconds
too high 5 sec. temperature

Fuel One second 3015 ECU Fuel Temp. 3 Amber


alarm every
Temp. signal source
30 seconds
too high high

Fuel One second 3016 ECU Fuel Temp. 3 Amber


alarm every
Temp. signal no
30 seconds
too high signal

Air filter One second Switch 1001 VCM Air filter 4 Red
alarm every
restriction C1-16 threshold
30 seconds
closed to
ground
for 5 sec.
Air cond. One second Switch 1003 VCM Air 4 Amber
alarm every
Not C1-10 conditioning
30 seconds
functional closed to high pressure
Vbat for
5 sec.
Hydraulic One second Switch 1004 VCM Hydraulic 4 Red
alarm every
Filter C1-17 filter
30 seconds
restriction closed to threshold
ground
for 5 sec.
Fuel One second DM1 1022 VCM 4 Amber
alarm every
contamin message
30 seconds
ated with
Water
(WIF)
Fuel One Fuel 1043 VCM Fuel sender 4 Amber
second
Level sender shorted high
alarm every
Sensor 30 seconds above 9 – park gauge
volts for
5 sec.
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 9 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Fuel One Fuel 1044 VCM Fuel sender 4 Amber
second
Level sender shorted low –
alarm every
Sensor 30 seconds below 0.5 park gauge
volts for
5 sec.
Fuel One Input is 1045 VCM Fuel sender 4 Amber
second
Level switched open circuit –
alarm every
Sensor 30 seconds battery park gauge
for 5 sec.
Trans. One second Trans 1046 VCM Trans Temp 4 Amber
alarm every
Temp Temp sender
30 seconds
Sensor sender shorted high
above 9
volts for
5 sec.
Trans. One second Trans 1047 VCM Trans Temp 4 Amber
alarm every
Temp Temp sender
30 seconds
Sensor sender shorted low
below 0.5
volts for
5 sec
Trans. One second Input is 1048 VCM Trans Temp 4 Amber
alarm every
Temp switched open circuit
30 seconds
Sensor battery
for 5 sec.
Brake One second Sender 1049 VCM Brake Temp. 4 Amber
alarm every
Temp. over sender out of
30 seconds
Sensor 1000 range
ohms for
5 sec.
General One second DTC’s VCM Only display 4 Amber
alarm
DM 1 3000 – with DM1
message 3366 request

Low Fuel One second VCM Low Fuel – 5 Amber


alarm
Warning must stay on
for remaining
key cycle
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 10 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Hour meter 9001 VCM Internal error 5 Green
Plausibility
Hour meter 9002 VCM Internal error 5 Green
RAM
Checksum
Failure
J1939 9003 VCM Internal error 5 Green
Receive
Buffer
Overflow
EEPROM 9004 VCM Internal error 5 Green
Checksum
Failure,
Hourmeter
Location 1
EEPROM 9005 VCM Internal error 5 Green
Checksum
Failure,
Hourmeter
Location 2
EEPROM 9006 VCM Internal error 5 Green
Checksum
Failure,
Hourmeter
Location 3
Abnormal 9007 VCM Internal error 5 Green
reset
Watchdog
Timeout
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 11 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

Appendix 5. Engine error codes


CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3006 X X X 10031 12 Coolant Temperature Sensor - Signal Not
Plausible (Compared with Engine Oil
Temperature)
3007 X X X X 10031 3 Coolant Temperature Sensor - Signal
Above Range Max.
3008 X X X 10031 4 Coolant Temperature Sensor - Signal
Below Range Min.
3009 X X X 10031 2 Coolant Temperature Sensor - (via CAN)
No Signal
3010 10033 3 Air Intake Temperature Sensor - Signal
Above Range Max.
3011 10033 4 Air Intake Temperature Sensor - Signal
Above Range Min.
3012 10033 2 Air Intake Temperature Sensor - (via
CAN) No Signal
3015 X X X X 10035 3 Fuel Temperature Signal - Signal Above
Range Max.
3016 X X X X 10035 4 Fuel Temperature Signal - Signal Below
Range Min.
3019 X X X 10034 3 Boost Pressure Sensor - Signal Above
Range Max.
3021 X X X 10034 2 Boost Pressure Sensor - (via CAN) No
Signal
3022 X X X 10034 12 Boost Pressure Sensor - Signal Not
Plausible
3023 X X X 100EB 12 Atmospheric Pressure Sensor - Signal
Not Plausible Compared with Boost
Pressure
3024 X X X 100EB 3 Atmospheric Pressure Sensor - Signal
Above Range Max.
3025 X X X 100EB 4 Atmospheric Pressure Sensor - Signal
Below Range Min.
3028 X X X X 20038 12 Oil Pressure Too Low
3029 X X X 10038 3 Oil Pressure Sensor – Short circuit to
Battery
3030 X X X 10038 4 Oil Pressure Sensor – Short circuit to
Ground
3031 X X X 10038 2 Oil Pressure Sensor - Hardware Error
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 12 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3032 X X X X 10038 12 Oil Pressure Sensor - Value Too High
3033 X X X 1003A 12 Oil Temperature Sensor - Signal Not
Plausible (Compared with Coolant
Temperature)
3034 X X X 1003A 3 Oil Temperature Sensor - Signal Above
Range Max.
3035 X X X 1003A 4 Oil Temperature Sensor - Signal Below
Range Min.
3036 X X X 1003A 2 Oil Temperature Sensor - (via CAN) No
Signal
3037 X X X 10034 4 Boost Pressure Sensor - Signal Low
3047 10025 3 Main Relay 2 Failure - Shortcircuit to
Battery
3048 10025 4 Main Relay 2 Failure - Shortcircuit to
Ground
3051 X X X X 10026 3 Battery Voltage to ECM too High
3052 X X X X 10026 4 Battery Voltage to ECM too Low
3059 20025 3 ECM Afterrun was Interrupted
3060 X X X 10061 12 Cylinder1 - Unclassifiable Error in
Injector
3061 X X X 10061 3 Cylinder1 - Injector Cable Short circuit
(Low Side to Battery)
3063 X X X 10061 2 Cylinder1 - Injector Cable Short circuit
(High Side to Ground)
3068 X X X 10063 12 Cylinder3 - Unclassifiable Error in
Injector
3069 X X X 10063 3 Cylinder3 - Injector Cable Short circuit
(Low Side to Battery)
3071 X X X 10063 2 Cylinder3 - Injector Cable Short circuit
(High Side to Ground)
3076 X X X 10062 12 Cylinder2 - Unclassifiable Error in
Injector
3077 X X X 10062 3 Cylinder2 - Injector Cable Short circuit
(Low Side to Battery)
3079 X X X 10062 2 Cylinder2 - Injector Cable Short circuit
(High Side to Ground)

CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 13 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
3080 X X X 10064 12 Cylinder4 - Unclassifiable Error in
Injector
3081 X X X 10064 3 Cylinder4 - Injector Cable Short circuit
(Low Side to Battery)
3038 X X X 10064 2 Cylinder4 - Injector Cable Short circuit
(High Side to Ground)
3088 X X X 10041 2 Crankshaft Sensor - No Signal
3089 X X X 10041 4 Crankshaft Sensor - Invalid Signal
3090 X X X 10043 2 Camshaft Sensor - No Signal
3091 X X X 10043 4 Camshaft Sensor - Invalid Signal
3093 X X X 10044 3 Offset Between Camshaft and Crankshaft
- Outside Boundaries
3095 X X X 10042 4 Operating with Camshaft Sensor Only -
Backup Mode
3102 X X X 10036 4 Rail Pressure Sensor CP3 - Signal Below
Range Min.
3104 X X X 10037 3 Rail Pressure Relief Valve – Open
3105 X X X 10037 4 Rail Pressure Relief Valve - Pressure
Shock Requested
3106 X X X 10037 2 Rail Pressure Relief Valve - Did Not Open
After Pressure Shock
3107 X X X 20059 3 Metering Unit – Short circuit to Battery
3108 30059 4 Metering Unit – Short circuit to Ground
3110 X X X 20036 3 Rail Pressure Sensor Monitoring - Signal
Above Range Max.
3111 X X X 20036 4 Rail Pressure Sensor Monitoring - Signal
Below Range Min.
3112 X X X 10036 3 Rail Pressure Sensor CP3 - Signal Above
Range Max.
3113 X X X 10028 3 Main Relay 1 – Short circuit to Battery
3114 X X X 20028 4 Main Relay 1 – Short circuit to Ground
3118 X X X 100E5 3 ECM 12V Sensor Supply Voltage High
3119 X X X 100E5 4 ECM 12V Sensor Supply Voltage Low
3131 X X X 1002E 3 Grid Heater Always Switched On
3137 X X X 10059 2 Metering Unit - Open Load
3138 X X X 10059 12 Metering Unit - Temperature Too High
3141 X X X 10058 3 Fuel Flow Set point Too Low
3142 1005B 3 High Pressure Test - Test Active
3145 10019 2 Terminal 15 - No Signal
3147 X X X 2003A 12 Oil Temperature Too High

CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3148 10032 12 Coolant Temperature Sensor Dynamic
Test - Failure (Minimum Temperature
Raise Not Reached)
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 14 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
3154 X X X 1002B 3 Grid Heater Relay – Short circuit to
Battery
3155 X X X 1002B 4 Grid Heater Relay – Short circuit to
Ground
3156 X X X 1002B 2 Grid Heater Relay - No Load
3171 X X X 10052 3 Rail Pressure Governor Deviation
Exceeded Max. Limit with Fuel Delivery
Quantity on Limit
3172 X X X 10053 3 Rail Pressure Governor Deviation
Exceeded Min. Limit with Fuel Delivery
Quantity on Limit
3173 X X X 10054 3 Rail Pressure Governor Deviation Below
Min. Limit for Speed
3174 X X X 10055 3 Rail Pressure Governor Deviation
Exceeded Max. Limit
3176 X X X 10057 3 Set point of Metering Unit Not Plausible
in Overrun
3177 1004D 3 Engine Over speed Detected
3188 X X X 10067 2 Cylinder1 Warning - Open Load
3192 X X X 10068 2 Cylinder2 Warning - Open Load
3196 X X X 10069 2 Cylinder3 Warning - Open Load
3200 X X X 1006A 2 Cylinder4 Warning - Open Load
3210 X X X 10071 3 Bank1 - General Short circuit on
Injection Cable
3211 X X X 10071 4 Bank1 - Injection Cable Short circuit Low
Side to Ground
3213 X X X 10071 12 Bank1 - Unclassifiable Error
3218 X X X 10073 3 Bank2- General Short circuit on Injection
Cable
3219 X X X 10073 4 Bank2 - Injection Cable Short circuit Low
Side to Ground
3221 X X X 10073 12 Bank2 - Unclassifiable Error
3227 X X X 1007C 3 Injection Processor (CY33X) Error -
Internal Reset / Clock Loss / Voltage Too
Low
3228 X X X 1007C 4 Injection Processor (CY33X) Error -
Unlocked / Initialization Failure
3229 X X X 1007C 2 Injection Processor (CY33X) Error -
Injections Limited By Software
3230 X X X 1007C 12 Injection Processor (CY33X) Error - SPI
Communication Failure

CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3231 X X X 2007C 3 Injection Processor Error - Internal Reset
/ Clock Loss / Voltage Too Low
3232 X X X 2007C 4 Injection Processor Error - Unlocked /
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 15 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
Initialization Failure
3233 X X X 2007C 2 Injection Processor Error - Test Mode
3234 X X X 2007C 12 Injection Processor Error - SPI
Communication Failure
3238 X X X 100D1 3 ECM Internal SPI Communication Error -
CJ940
3239 100D2 4 ECM EEPROM - Read Operation Failure
3240 100D2 2 ECM EEPROM - Write Operation Failure
3241 100D2 12 ECM EEPROM - Default Value Used
3242 X X X 100D3 12 ECM (Locked) Recovery Occurred
3243 X X X 200D3 12 ECM Recovery (Suppressed) - Recovery
Occurred
3244 X X X 300D3 12 ECU Recovery (Visible) - Recovery
Occurred
3245 X X X 100D4 12 ECM Processor - Watchdog Not Plausible
3246 X X X 100D5 4 Shutoff Paths During Initialization -
Watchdog
3247 X X X 100D5 2 Shutoff Paths During Initialization -
Supply Voltage Too High
3248 X X X 100D5 12 Shutoff Paths During Initialization -
Supply Voltage Too Low
3249 X X 100D6 12 TPU Monitoring - Time Deviation
between TPU and System Not Plausible
3250 X X 100D7 2 Dataset - Variant Defective
3251 X X 100D7 12 Dataset - Requested Variant Could Not
Be Set
3252 X X 100D8 12 Controller Watchdog - SPI
Communication Failure
3253 X X X 100D9 3 ADC Monitoring - Reference Voltage Too
Low
3254 X X X 100D9 4 ADC Monitoring - Reference Voltage Too
High
3255 X X X 100D9 2 ADC Monitoring - Test Impulse Error
3256 X X X 100D9 12 ADC Monitoring - Queue Error
3258 X X X 100E1 3 High Side Power – Short circuit to
Battery
3259 X X X 100E1 4 High Side Power – Short circuit to
Ground
3260 X X X 200E1 2 Low Side Power - Open Load
3261 X X X 200E1 3 Low Side Power – Short circuit to Battery
of Excess Temperature
3262 X X X 200E1 4 Low Side Power – Short circuit to Ground

CNH Wheel TLB TLB Amber Red DMx SPN FMI Short Failure Description
DTC Loader ICON Warning Stop (Hex).
(Dec.)
3263 X 100B3 3 ECM Bus Off on CAN C
3265 X X 100E3 3 Overrun Monitoring - Injection Time
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 16 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West
Too Long
3266 X X X 100E4 3 Redundant Engine Speed in Overrun
Monitoring - Speed Signal Not Plausible
3278 X X X 100E9 3 ECM Internal Supply Voltage Too High -
CJ940 Above Limit
3279 X X X 100EA 4 ECM Internal Supply Voltage Too Low -
CJ940 Below Limit
3280 X X X 100E6 3 Sensor Supply Voltage 1 – High
3281 X X X 100E6 4 Sensor Supply Voltage 1 – Low
3283 X X X 100E7 3 Sensor Supply Voltage 2 – High
3284 X X X 100E7 4 Sensor Supply Voltage 2 – Low
3285 X X X 100E8 3 Sensor Supply Voltage 3 – High
3286 X X X 100E8 4 Sensor Supply Voltage 3 - Low
3316 1006E 3 Minimum Number of Injections Not
Reached - Stop Engine
3334 X X X 100C6 3 Timeout of CAN message TSC1-PE
Torque
3339 X X X 100C8 3 Timeout of CAN message TSC1-VE
Speed
3350 1001A 3 Terminal 50 - Always On
3361 100D2 3 ECM EEPROM - General Erro
3363 X X 100EB 2 Atmospheric Pressure Sensor -
Processed via ADC (no CAN Plausibility
Performed)
3998 X X X Unknown unknown error code with amber lamp
3999 X X X Unknown possible unknown error code with red
lamp
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 17 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

In the following table, the park brake activation law is described:

FUNCTION without seat switch Telltale ACTIVATION LAW


Parking brake is off and the unit is in gear No alarm
Parking brake is off and the unit is in neutral No alarm
Continuous
Parking brake is on and the unit is in gear Alarm
Red LCD
No alarm
Parking brake is on and the unit is in neutral

FUNCTION with seat switch telltale ACTIVATION LAW


Parking brake is off, seat is not facing forward Continuous Alarm
Amber LCD and the unit is in gear
show in amber for 3 sec. One second alarm
with 50% duty ratio Parking brake is off, seat is not facing forward,
and the unit is in neutral

Parking brake is off, seat is facing forward and No alarm


the unit is in gear
Parking brake is off, seat is facing forward and No alarm
the unit is in neutral
Continuous Alarm
Parking brake is on, seat is not facing forward
Red LCD and the unit is in gear

Parking brake is on, seat is not facing forward, No alarm


and the unit is in neutral
Continuous Alarm
Parking brake is on, seat is facing forward and
Red LCD the unit is in gear

Parking brake is on, seat is facing forward and No alarm


the unit is in neutral
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 18 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

APPENDIX 6: Draft List of BRAND STRATEGY, HARDWARE and


BUILD LOCATION.

High Level Cluster Configurations:


Imola
 New Holland NA/Eu. 2ws (Electronic) Tier 3 P/N 87521757

o Maxima side console cluster with new New Holland appliqué.

o Standard front console cluster (with optional speedometer) from CIAM (new appliqué to
more closely match Maxima cluster).

 New Holland NA/Eu. 4ws (Electronic) Same P/N as 2 wheel steering.

o Maxima side console cluster. Same as New Holland Electronic 2ws.

o Standard CIAM front console with speedometer & 4ws lights (new appliqué to more
closely match the Maxima cluster).

 Case Eu. 2ws (Electronic) Tier 3 P/N 87527687

o Maxima side console cluster with integral speedometer and Case "R" Series appliqué.

 Case Eu. 4ws (Electronic) A full complexity that has the same P/N as 2 wheel steering.

Burlington

 Case NA (Electronic) Tier 3 P/N 87521765

o Maxima side console cluster with Case "M" Series appliqué.


Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 19 of 83 ES-D418

Models Affected: Rev.: Date: Control:


New Holland B110,LB110,B115 and LB115 Case 590 and 695 B OCT’ 06 S. West

APPENDIX 7: LOW BATTERY VOLTAGE MANAGEMENT


NOTES:
When the voltage is below 9 Volts, errors related to the VCM, shall not be displayed not stored