Professional Documents
Culture Documents
Codigo Error B95, B110B
Codigo Error B95, B110B
During cranking all the warning detection activities have to be stopped (SEE APPENDIX 4)
Each warning based on a can message shall be activated if the message is received for three times in a
row and only if the value contained into relevant message is valid (that means not FFFE or FFFF).
Each warning based on a direct input should be filtered as per the diagram below indicated unless
specified differently. The de-activation timer does not correspond to the visualization of a specific
warning. If there is an error code active relevant to a specific sensor, all the warnings related to that
sensor has to be deactivated.
For all those warnings which are activated upon the engine speed presence, whenever the Engine speed
value (either direct reading or CAN message) is not correct, the Engine oil pressure value has to be used
as a reference.
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 2 of 83 ES-D418
Warning
activation
t
1sec
debounce
debounce
5 sec
activation de -activation
filter filter
Switch
/Sensor
commutation
for
warning
condition
t
Time
trigger
for
warning
activation
counter
t
Warning
activation
t
t<5 sec t<5 sec 5 sec
debounce
debounce
debounce
debounce
debounce
NOTE: Counter needs to be reset to 0 all the times the reading of a switch/sensor goes to 0
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 3 of 83 ES-D418
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
CAN 5 sec. 1057 VCM Timeout of 1 Red
malfunction
without CAN message
Continuous
message Vehicle
Electrical
CAN Continuous 5 sec. 1058 VCM Timeout of 1 Red
malfunction
without CAN message
message EDC2BC
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Engine oil Continuous Pressure 3032 ECU 2 Red
pressure depends
too high on speed
Battery 3051 ECU Battery 2 Red
Charge
voltage to
voltage too Continuous
high ECM too high
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Foot One second Voltage 1029 VCM Foot throttle 2 Amber
Throttle alarm every
over 9 sensor –
signal out of 30 seconds
range volts for shorted high
5 sec. to Vbat
Foot One second Voltage 1030 VCM Foot throttle 2 Amber
Throttle alarm every
under 0.5 sensor –
signal out of 30 seconds
range volts for shorted low
5 sec. to ground
Foot One second Voltage 1023 VCM Foot throttle 2 Amber
alarm every
throttle over supply
30 seconds
5 volt 5.1 volts voltage too
supply for 5 sec. high
Foot One second Voltage 1024 VCM Foot throttle 2 Amber
alarm every
throttle under 4.9 supply
30 seconds
5 volt volts for voltage too
supply 5 sec. low
Foot One second Voltage 1025 VCM Foot throttle 2 Amber
alarm every
throttle over 9 supply
30 seconds
5 volt volts for shorted high
supply 5 sec. to Vbat
Foot One second Voltage 1026 VCM Foot throttle 2 Amber
alarm every
throttle under 0.5 supply
30 seconds
5 volt volts for shorted low
supply 5 sec. to ground
Hand One second Throttle 1035 VCM Hand throttle 2 Amber
Throttle alarm every
above sensor –
signal out of 30 seconds
range 4.75 volts signal above
for 5 sec. range
Hand One second Throttle 1036 VCM Hand throttle 2 Amber
Throttle alarm every
below sensor –
signal out of 30 seconds
range 0.25 volts signal above
for 5 sec. range
Hand One second 1037 VCM Hand throttle 2 Amber
Throttle alarm every
sensor – no
signal out of 30 seconds
range signal
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Trans. Oil One second Coolant 1020 VCM Trans over 3 Amber
alarm every
above above operating
30 seconds
105° C 105° C temperature
for 5 sec.
Fuel One second Fuel over 1021 VCM Fuel over 3 Amber
alarm every
Temp. 82° C for operating
30 seconds
too high 5 sec. temperature
Air filter One second Switch 1001 VCM Air filter 4 Red
alarm every
restriction C1-16 threshold
30 seconds
closed to
ground
for 5 sec.
Air cond. One second Switch 1003 VCM Air 4 Amber
alarm every
Not C1-10 conditioning
30 seconds
functional closed to high pressure
Vbat for
5 sec.
Hydraulic One second Switch 1004 VCM Hydraulic 4 Red
alarm every
Filter C1-17 filter
30 seconds
restriction closed to threshold
ground
for 5 sec.
Fuel One second DM1 1022 VCM 4 Amber
alarm every
contamin message
30 seconds
ated with
Water
(WIF)
Fuel One Fuel 1043 VCM Fuel sender 4 Amber
second
Level sender shorted high
alarm every
Sensor 30 seconds above 9 – park gauge
volts for
5 sec.
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 9 of 83 ES-D418
Function Master Audible Telltale LCD Condition DTC SA Verbal Priority LCD Color
Lamp
Alarm Lamp Icon description
Fuel One Fuel 1044 VCM Fuel sender 4 Amber
second
Level sender shorted low –
alarm every
Sensor 30 seconds below 0.5 park gauge
volts for
5 sec.
Fuel One Input is 1045 VCM Fuel sender 4 Amber
second
Level switched open circuit –
alarm every
Sensor 30 seconds battery park gauge
for 5 sec.
Trans. One second Trans 1046 VCM Trans Temp 4 Amber
alarm every
Temp Temp sender
30 seconds
Sensor sender shorted high
above 9
volts for
5 sec.
Trans. One second Trans 1047 VCM Trans Temp 4 Amber
alarm every
Temp Temp sender
30 seconds
Sensor sender shorted low
below 0.5
volts for
5 sec
Trans. One second Input is 1048 VCM Trans Temp 4 Amber
alarm every
Temp switched open circuit
30 seconds
Sensor battery
for 5 sec.
Brake One second Sender 1049 VCM Brake Temp. 4 Amber
alarm every
Temp. over sender out of
30 seconds
Sensor 1000 range
ohms for
5 sec.
General One second DTC’s VCM Only display 4 Amber
alarm
DM 1 3000 – with DM1
message 3366 request
CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 13 of 83 ES-D418
CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3148 10032 12 Coolant Temperature Sensor Dynamic
Test - Failure (Minimum Temperature
Raise Not Reached)
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 14 of 83 ES-D418
CNH Wheel TLB TLB Amber Red DMx FMI Short Failure Description
DTC Loader ICON Warning Stop SPN
(Dec.) (Hex).
3231 X X X 2007C 3 Injection Processor Error - Internal Reset
/ Clock Loss / Voltage Too Low
3232 X X X 2007C 4 Injection Processor Error - Unlocked /
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 15 of 83 ES-D418
CNH Wheel TLB TLB Amber Red DMx SPN FMI Short Failure Description
DTC Loader ICON Warning Stop (Hex).
(Dec.)
3263 X 100B3 3 ECM Bus Off on CAN C
3265 X X 100E3 3 Overrun Monitoring - Injection Time
Engineering Specifications
Title: Page: No.:
2007 TLB VCM Specification 16 of 83 ES-D418
o Standard front console cluster (with optional speedometer) from CIAM (new appliqué to
more closely match Maxima cluster).
o Standard CIAM front console with speedometer & 4ws lights (new appliqué to more
closely match the Maxima cluster).
o Maxima side console cluster with integral speedometer and Case "R" Series appliqué.
Case Eu. 4ws (Electronic) A full complexity that has the same P/N as 2 wheel steering.
Burlington