WELCOME

QUICK START GUIDE This user guide can let users be familiar with this series quickly. Please go through this
user guide carefully before operating.
传感器位置
FOR DATA LOGGERS GETTING STARTED
All you need to prepare are a PC running under Window XP/ Vista/7/8 (32 bit or 64 bit)
with USB port and CD-ROM drive, the CD including Data Logger DGraph software and
Driver, the data logger itself and 2pcs 1.5V triple A battery.

1. SIM CARD INSTALLED ON DATA LOGGER


Need to prepare one 2G SIM card for Data Loggers with GSM SMS alarm function. This
2G SIIM card should have enough money to support the charge. Please insert the SIM
card according to the picture shows on this cover. With hearing the “click” you can insert
the SIM card well; press SIM card again it will pop up automatically and can take it out if
need to change. Data logger could be abnormal if SIM not being installed correctly.

Card slot
2. BATTERY INSTALLATION
Take out battery from the package and open the back cover on the device; Notice the
cathode, install the battery properly and close cover, then device will be turned on
USB port automatically after power supply. Readings also displayed on the LCD.
Special reminding, for Data Logger with GSM SMS alarm function, battery is only
used to maintain the instrument internal clock as well as the system for a short
ºC/º F
period of time. External power supply must be inserted to support the GSM
N
MA X/ MI ON /OF F function when it is in specific work environment after battery installed and some
STOP
STAR T/
necessary settings. After inserting the external power supply, please pay attention
to the screen on the left if there is a sign G around 15 seconds. If there is no sign G,
there should be some problem with the network and have to check whether SIM
card and battery are installed correctly.

3. DRIVER AND SOFTWARE INSTALLATION


Inset the CD into your PC CD-ROM drive; double click the “USBXpressInstaller.exe” file
included on the CD ->Driver Directory to start installing. Users can see the “ Silicon
SMS Laboratories USBXpress Device Driver Installer” dialog first, click “Install” to follow
the prompts until it shows “Success”. Then click the “setup.exe” in the “Software” file
140926GSM0000027-Logger1: directory and follow the prompts till complete the software installation. After software
installation, then plug the data logger to PC USB port to get ready to setup.
TEMP(28.5C);
HUMI(53.9%rh);
BAT OK;

4. SETUP AND START 5. SETUP SMS ALRM NUMBER


Please do the necessary data logger settings according to the following steps: Click “SMS Alarm Phone Number Setup” button on the Data Logger Setup dialog, enter
1.Make sure the data logger battery installed correctly and connected to PC USB port the mobile phone number via which you want to get the alarm message when SMS
properly. alarm appears. 5 mobile phone numbers available at most and please make sure the
2.Double click the “Data Logger Graph” icon on your Windows desktop. This will load the Data integrality and the accuracy of the input numbers, otherwise users can not receive the
Logger Graph software. On the left top of the software, you can see “Start” button and click on SMS normally. Meanwhile, users can query the Data Logger readings and battery
it. This will open “Data Logger Device” dialog. Select data logger device that will be set (or status by dialing the Data Logger and this number will be written into the alarm number
default). Here you can check the serial NO, firmware version, status, etc. of the selected data list automatically. Notice: the top mobile number in the 5 numbers list will be
logger device. If no information display, then you have to check if the connecting or the driver forced to delete if Data Logger being written more than 5 numbers.
is normal. NOTE:
3.Click on the “Setup” button to load “Data Logger Setup” dialog. Here you can follow the User can send “DAM”
screen instructions and setup the data logger. SMS to the data
4.On the “General”, you can set logger name, sample rate (Notice: For data logger with GSM logger to disable any
SMS alarm function, it only can support letters A-Z and 0-9) and visiting password. alarm function, or
5.On the “Channel Settings”, you can set high/low limit, enable/disable alarm, and send “EAM” SMS to
enable/disable alarm hold. Notice that to enable the corresponding channel alarm function so enable alarm function
that this data logger can make sound and light alarm and SMS alarm. Data Logger will sound
and light alarm and sending message once setting limits being exceeded or battery is low.
Meanwhile, users can choose alarm delay, alarm immediately on settings. Data Logger will
send messages to all mobile phone numbers written into the logger ( 5 mobile phone numbers
at most), 2 messages at most for each mobile phone number and then it will dial the first
mobile phone until user hangs up the phone, interval at 5 minutes. Alarm will not stop if
enabled the alarm hold function.
6.On the “Start and Stop Method”, you can select how to start and stop logging by your actual
demands. Strongly suggest choose by “Press button” method to start and stop. In this case,
users can operate Data Logger by long pressing to start or stop repeatedly without connecting
to PC. Also all settings can be factory default if first attempts. Click on the “Finished” button
or escape with “Cancel”.
7.After finishing setting up, data logger will start according to your settings. Plug out the data
logger and put in the specific work environment. Notice if data logger needs external power
support or being logging status.

SMS ALARM EXAMPLE


Serial No. Logger Name (only support A-Z and 0-9)

Example 1
140926GSM0000027-Logger1:
Temperature reading is normal
TEMP(28.5C) OK;
Humidity reading is normal
HUMI(53.9%rh) OK;
BAT OK; Battery status is normal

Serial No. Logger Name (only support A-Z and 0-9)

Example 2
140926GSM0000027-Logger1:
Temperate reading exceeds the
TEMP(28.5C) EXD setting limits
LMT(2.0~20.0); Setting limits ( Low limit-High limit)
Humidity reading exceeds the
HUMI(76.9%rh)EXD
setting limits
LMT(40.0~70.0);
Setting limits (Low limit-High limit)
BAT LOW; Low battery

2 3
7. GRAPH 6. DATA DOWNLOAD
1.Click on the “Download” button on the “Data Logger Device” dialog. Here you can
1. User can open a data logger file (*.dlg, *.mdlg) via the menu “File->Open”, and the
follow the screen instructions to download and save the data to PC. Please note that
graph will be shown.
you need to input correct password to operate this step if the data logger has been set a
2. Zoom in: Use the mouse to click and drag a box around any graph area to magnify thearea
password before (No for factory default).
selected. Zoom out: Click on the "Undo Last" or "Undo All" button on tool bar to showlast graph
2.After downloading finished, a “Downloading Finished” dialog will be shown, user
area or the original graph area.
can click the “Open” button to graph the downloaded data.
3. Pan: Press and hold the mid-button of the mouse at any graph location, and move themouse to
pan the graph area.
4. Zoom and Pan Method. Auto: Zoom and pan in any direction. Horizontal: Zoom and panonly in
horizontal direction. Vertical: Zoom and pan only in vertical direction. Manually: Setthe start time
and end time for horizontal axis, and set the scale for the vertical axis.
5. Mark Data Points: Click right-button on graph area to show the pop-up menu below,
Click "Mark Data Points" to show marks on all sample point locations.
6. Graph Settings: Click right-button on graph area to show the pop-up menu below, click“Graph
Settings” to show a dialog. User can set color, font, line size and unit for the graph.

LCD DISPLAY AND BUTTONS INSTRUCTIONS


(non-recording status)
Maximum reading
Minimum reading Memory using status

Temperature unit

Temperature reading

Humidity unit

Humidity reading
8. FILE EXPORT
The software save and open the *.dlg or *.mdlg file type in default. User can click “File- Low battery
>Save As” to save the *.dlg or *.mdlg as other file types, including *.txt, *.csv, *.xls, *.bmp, indication
and *.jpg.

9. PRINT Network signal Time/Year/Month/Date


1.To print the graph, statistics and data USB connecting indication
table, click on the printer icon on Data Logger is not in Logging mode when there is no LOG symbol on the right top of
standard toolbar orselect “Print” from LCD display.
the “File” pull-down menu. LCD displays the real-time readings and refresh every 16 seconds.
2.User can also click the “File->Print Users single press the MAX/MIN/START/STOP button can have the Maximum and
Minimum readings since the data logger gets.
and Export Options” select the printed
Users single press C/F/ON/OFF button can switch the temperature unit. Long press
contents in thefollowing dialog.
this button can turn on/turn off the LCD display. Notice: there will be no date/time
display if data logger has no setup with PC after installing battery.
4 5

LCD DISPLAY AND BUTTONS INSTRUCTIONS


(under logging mode)
Maximum reading LOG symbol showing
Minimum reading being logging status Memory using status

Alarm symbol shows


exceeding the Temperature unit
temperature limit

Temperature reading
Alarm symbol show
exceeding the Humidity unit
humidity limit

Humidity reading

Low battery
indication

Network signal
Time/Year/Month/Date
USB connecting indication DGraph TM

Data Logger is in Logging mode when there is LOG symbol on the right top of LCD display.
LCD displays the real-time readings and refresh every 16 seconds.
Users single press the MAX/MIN/START/STOP button can have the Maximum /minimum
readings that the data logger records. Notice: Suggest choose the Press Button to start
and stop method, in this case, user can long press this Button to start or stop with no need
connecting to PC to setup.
Users single press C/F/ON/OFF button can switch the temperature unit. Long press this
button can turn on/turn off the LCD display. Notice: If you want to start recording, you have
to connect Data Logger with PC to finish some necessary settings after installing battery.

NOTICES
•Make sure if Data Logger should be supported by external power. Accessory
•Knowing the waterproof level, measuring range, accuracy, work environment well
and put the Data Logger in correct situation properly.
•Some sensors will age and drift inevitably, and if necessary, you can consult your
supplier to get help on recalibration.

Special Reminding:
For further information on the software, you can access the Help menu on the