Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SUNRISE TELECOM®

The Datacom/
Datacom/DDS Module SSxDSL-9
DDS Module is
part of a family of Data Sheet
plug-in modules
for the SunSet
MTT® and xDSL The SSxDSL-9 Datacom/DDS Module, part of the SunSet Modular Test
test sets Toolkit (MTT) family of products, is a rugged, battery-operated handheld
test solution for WAN/data, Frame Relay, and DDS service verification. The
module is designed to assist technicians in bringing up new data com-
munication service and troubleshooting the existing data network fast
and effectively. The powerful test module can be used for all your testing
requirements including, DTE/DCE emulation for end-to-end testing of data
networks, bidirectional monitoring for a greater level of troubleshooting
for data networks, FOX testing for Frame Relay CIR verification, and Frame
Relay Ping testing for checking link connectivity.

features applications
Datacom CSU/DSU CPE Mode
• DTE/DCE emulation DSU/CSU

• Bidirectional monitoring with Y-adapter Cha n


ne l B
ank
OCU
-D
• V.35, RS232, RS449, RS530, X.21 P

• Data rates from 2400 bps to 2.048 Mbps Central Office Customer Premises

• Bit error rate testing with stress patterns


• Control lead status monitor for CTS, RTS, DSR, DTR DTE Emulation
• Received data display DTE DTE

• Frame relay UNI/NNI testing


DCE DCE
DDS 4-Wire
• CSU/DSU emulation
• Bit error rate testing on a primary channel DCE Emulation
DCE
• Loopback testing
• Received data display
DTE

benefits
Datacom Monitoring
• Lightweight
Datacom
• Flexible modular design Monitor

• Eliminates the need for multiple instruments


• Intuitive and easy-to-use CSU
/D SU

• Cost-effective and future-proof CPE/Router

www.sunrisetelecom.com
datacom specifications Frame Relay NNI (SWxDSL-9FRNNI)
LMI standards: ITU-T Q.933, ANSI T1.617, LMI (DLCI 1023, GOF
Supports V.35, X.21/V.11, RS232/V.24, RS449/V.36, RS530 interfaces Vendors), NO LMI
Test modes: DTE Emulation, DCE Emulation, Bidirectional monitoring Modes: NNI USER, NNI NETWORK
Connector: SCSI port with adapter cables
LMI Analysis, PING Test, FOX Test, Statistic Analysis - as
described in Frame Relay Basic section
Operation Modes
DTE Emulation
• Point-to-point or point-to-loopback BERT
• Control and analyze datacom control leads DDS 4-Wire Specifications
DCE Emulation Test modes: CSU/DSU Emulation
• Point-to-point BERT Signal: Bipolar return to zero with alternate mark inversion
• Control and analyze datacom control leads Primary channel conforms to AT&T PUB 62310
Connector: 8-pin modular RJ-48
Datacom Monitoring
• Bidirectional monitoring with Y-adapter cable Operation Mode
• Monitor control leads, frequency
CSU/DSU CPE Mode
Measurements • BERT testing at the DDS-4W interface
Bit error/G.821 • Test primary channels
Error count and rate • Respond to DSU/CSU loop codes
ITU-T G.821 Analysis
Data loss, data loss seconds, pattern loss, pattern loss seconds Measurements
Datacom interface analysis Frequency, LOSS, LOFS, EXZS, OOS, OOFS, BPVs, FBEs
View received data Bit error/G.821 Analysis
Propagation delay View received data

Frame Relay Basic (SWxDSL-9FRA) Loopback Testing


LMI standards: ITU-T Q.933, ANSI T1.617, LMI (DLCI 1023, GOF Transmit: Latching DSU/CSU
Vendors), NO LMI Internal loopback: Manual or auto-respond to DSU/CSU command
Modes: UNI DTE, UNI DCE
Status/Alarm Indicators
LMI Analysis Dual-color LEDs indicator
Results: Link OK Total, Link Errored Total, Timeout Error, Response Current status and alarm history conditions
Sequence Number, Wrong Message
PVC status

PING Test
Product description
Results: Number of PINGs, Number of PINGs sent, PING status Module size (WxLxH): 5.0 x 3.5 x 0.9 in (12.6 x 9 x 2.2 cm)
(Received, Unreached, Errored), Round Trip Time (Current, Operating temperature: 32˚ to 122˚F (0˚ to 50˚C)
Average, Maximum, Minimum) Storage temperature: -4˚ to 158˚F (-20˚ to 70˚C)
InARP support Humidity: 5% to 85% noncondensing
IP encapsulation conforms to RFC1490 specification
Echo PING

FOX Test ORDERING INFORMATION


Results: PVC Status, Current Rate, Errored Frames, RSN Error, SSN SSxDSL-9 Datacom/DDS Module
Error, Frame Check Sequence (FCS) Error, Count of Frame Re- Testing at both Datacom and DDS-4W interfaces
ceived with FECN, with BECN, with DE, Count of transmit frames, SWxDSL-9FRA Frame Relay Basic
Count of received frames SWxDSL-9FRNNI Frame Relay NNI
[Requires SWxDSL-9FRA]
Statistics Analysis
Bidirectional monitoring
Frame relay performance and statistics
DLCI analysis and statistics

For more information or a directory of sales offices: info@sunrisetelecom.com www.sunrisetelecom.com

© 2007 Sunrise Telecom Incorporated. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their respective corporations.
Sunrise Telecom San Jose, Modena, and Taiwan facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Sunrise Telecom. REV.A01 April 2007