Test for Granular Sub Base

Atterberg Limit Test


Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.4 22.2 24.3 26.8 -
Penetration in (mm) 16.7 18.4 20.2 22.4 -

Liquid Limit (LL) = 23.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.4 19.3 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 5.05 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.05 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.7 19.4
18.4 22.2
20.2 24.3
22.4 26.8

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.4 22.3 24.5 26.4 -
Penetration in (mm) 17.6 19.4 20.8 22.4 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.2 18.6 -
Plastic Limit (PL) = 17.9 %
Plasticity Index (PI) = LL - PL = 5.4 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.40 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.6 20.4
19.4 22.3
20.8 24.5
22.4 26.4

23.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 17.2 21.3 24.2 26.8 -
Penetration in (mm) 15.5 18.6 20.4 22.3 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.6 20.3 -
Plastic Limit (PL) = 19.95 %
Plasticity Index (PI) = LL - PL = 3.55 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.55 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.5 17.2
18.6 21.3
20.4 24.2
22.3 26.8

22.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.3 22.5 23.8 26.8 -
Penetration in (mm) 16.8 19.1 20.2 22.1 -

Liquid Limit (LL) = 23.70 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.7 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.3 20.1 -
Plastic Limit (PL) = 19.2 %
Plasticity Index (PI) = LL - PL = 4.5 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.50 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.8 19.3
19.1 22.5
20.2 23.8
22.1 26.8

23.1
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 23.4 25.1 26.2 -
Penetration in (mm) 15.3 19.2 21.1 22.2 -

Liquid Limit (LL) = 24.20 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 19.5 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 5.35 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.35 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.3 20.1
19.2 23.4
21.1 25.1
22.2 26.2

23.7
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 23.9 25.9 -
Penetration in (mm) 16.6 17.9 19.1 20.3 -

Liquid Limit (LL) = 25.40 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 25.4 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 21.2 19.9 -
Plastic Limit (PL) = 20.55 %
Plasticity Index (PI) = LL - PL = 4.85 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.85 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.6 20.5
17.9 22.6
19.1 23.9
20.3 25.9

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 22.2 23.5 25.5 -
Penetration in (mm) 16.9 18.2 19.4 20.6 -

Liquid Limit (LL) = 24.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.5 21.1 -
Plastic Limit (PL) = 19.8 %
Plasticity Index (PI) = LL - PL = 4.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.9 20.1
18.2 22.2
19.4 23.5
20.6 25.5

22.8
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 24.9 25.9 -
Penetration in (mm) 17.7 19.1 20.5 21.5 -

Liquid Limit (LL) = 24.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.1 19.5 -
Plastic Limit (PL) = 19.3 %
Plasticity Index (PI) = LL - PL = 4.7 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.70 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.7 20.5
19.1 22.6
20.5 24.9
21.5 25.9

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 24.9 26.5 -
Penetration in (mm) 17.3 19.2 21.2 22.8 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.9 18.8 -
Plastic Limit (PL) = 18.35 %
Plasticity Index (PI) = LL - PL = 4.95 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.95 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.3 20.3
19.2 22.4
21.2 24.9
22.8 26.5

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 25.1 26.5 -
Penetration in (mm) 16.9 18.7 21.7 22.6 -

Liquid Limit (LL) = 23.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.9 -
Plastic Limit (PL) = 19.7 %
Plasticity Index (PI) = LL - PL = 3.9 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.90 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.9 20.3
18.7 22.4
21.7 25.1
22.6 26.5

23.6
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 25.1 26.5 -
Penetration in (mm) 16.5 18.2 20.9 22.1 -

Liquid Limit (LL) = 24.20 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.8 19.5 -
Plastic Limit (PL) = 19.15 %
Plasticity Index (PI) = LL - PL = 5.05 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.05 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.5 20.3
18.2 22.4
20.9 25.1
22.1 26.5

23.6
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.9 21.9 24.1 25.9 -
Penetration in (mm) 15.2 17.6 19.5 21.3 -

Liquid Limit (LL) = 24.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.9 -
Plastic Limit (PL) = 19.7 %
Plasticity Index (PI) = LL - PL = 4.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.2 19.9
17.6 21.9
19.5 24.1
21.3 25.9

23.0
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.2 20.9 22.5 25.1 -
Penetration in (mm) 15.8 17.6 18.9 21.5 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 19.9 -
Plastic Limit (PL) = 19.05 %
Plasticity Index (PI) = LL - PL = 4.45 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.45 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.8 19.2
17.6 20.9
18.9 22.5
21.5 25.1

21.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.3 22.2 24.2 26.8 -
Penetration in (mm) 16.3 18.4 20.5 22.5 -

Liquid Limit (LL) = 23.80 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.8 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.8 19.5 -
Plastic Limit (PL) = 19.15 %
Plasticity Index (PI) = LL - PL = 4.65 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.65 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.3 19.3
18.4 22.2
20.5 24.2
22.5 26.8

23.1
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.2 20.8 22.5 25.1 -
Penetration in (mm) 17.8 18.5 19.2 20.5 -

Liquid Limit (LL) = 24.10 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.8 19.3 -
Plastic Limit (PL) = 19.55 %
Plasticity Index (PI) = LL - PL = 4.55 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.55 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.8 19.2
18.5 20.8
19.2 22.5
20.5 25.1

21.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.5 22.8 24.1 24.8 -
Penetration in (mm) 17.9 19.5 21.3 22.2 -

Liquid Limit (LL) = 23.10 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.5 18.9 -
Plastic Limit (PL) = 18.2 %
Plasticity Index (PI) = LL - PL = 4.9 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.90 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.9 21.5
19.5 22.8
21.3 24.1
22.2 24.8

23.3
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.1 24.6 25.6 -
Penetration in (mm) 15.5 17.9 21.8 22.9 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.6 -
Plastic Limit (PL) = 19.55 %
Plasticity Index (PI) = LL - PL = 3.95 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.95 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.5 20.3
17.9 22.1
21.8 24.6
22.9 25.6

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.2 22.1 24.8 25.3 -
Penetration in (mm) 18.3 19.5 21.3 22.2 -

Liquid Limit (LL) = 23.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.9 -
Plastic Limit (PL) = 19.7 %
Plasticity Index (PI) = LL - PL = 3.3 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.30 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

18.3 21.2
19.5 22.1
21.3 24.8
22.2 25.3

23.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.2 22.1 24.1 25.3 -
Penetration in (mm) 17.5 18.7 20.9 22.1 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 22.2 -
Plastic Limit (PL) = 20.2 %
Plasticity Index (PI) = LL - PL = 3.1 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.10 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.5 21.2
18.7 22.1
20.9 24.1
22.1 25.3

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.2 22.1 24.1 25.3 -
Penetration in (mm) 14.9 16.5 19.7 20.8 -

Liquid Limit (LL) = 24.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 22.2 -
Plastic Limit (PL) = 20.2 %
Plasticity Index (PI) = LL - PL = 4.4 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.40 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

14.9 21.2
16.5 22.1
19.7 24.1
20.8 25.3

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 23.9 25.1 -
Penetration in (mm) 16.2 19.7 21.6 22.9 -

Liquid Limit (LL) = 23.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.6 22.7 -
Plastic Limit (PL) = 20.15 %
Plasticity Index (PI) = LL - PL = 2.85 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 2.85 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.2 20.5
19.7 22.6
21.6 23.9
22.9 25.1

23.0
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 23.9 25.1 -
Penetration in (mm) 16.6 17.9 19.1 20.3 -

Liquid Limit (LL) = 24.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.9 22.7 -
Plastic Limit (PL) = 20.8 %
Plasticity Index (PI) = LL - PL = 4.1 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.10 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.6 20.5
17.9 22.6
19.1 23.9
20.3 25.1

23.0
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 23.6 25.3 26.2 -
Penetration in (mm) 17.1 20.1 21.6 22.9 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.2 21.8 -
Plastic Limit (PL) = 19.5 %
Plasticity Index (PI) = LL - PL = 3.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.1 20.1
20.1 23.6
21.6 25.3
22.9 26.2

23.8
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 23.6 25.3 26.2 -
Penetration in (mm) 15.3 19.2 21.5 22.2 -

Liquid Limit (LL) = 24.20 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.6 21.5 -
Plastic Limit (PL) = 20.05 %
Plasticity Index (PI) = LL - PL = 4.15 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.15 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.3 20.1
19.2 23.6
21.5 25.3
22.2 26.2

23.8
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.2 22.9 24.6 26.2 -
Penetration in (mm) 17.1 19.6 22.3 25.1 -

Liquid Limit (LL) = 23.10 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.5 19.8 -
Plastic Limit (PL) = 18.65 %
Plasticity Index (PI) = LL - PL = 4.45 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.45 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.1 21.2
19.6 22.9
22.3 24.6
25.1 26.2

23.7
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.4 20.3 23.4 24.8 -
Penetration in (mm) 14.9 16.5 19.7 20.8 -

Liquid Limit (LL) = 23.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 22.1 -
Plastic Limit (PL) = 20.8 %
Plasticity Index (PI) = LL - PL = 3.1 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.10 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

14.9 18.4
16.5 20.3
19.7 23.4
20.8 24.8

21.7
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 23.4 24.5 25.4 -
Penetration in (mm) 15.7 19.5 21.3 22.2 -

Liquid Limit (LL) = 23.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.5 20.2 -
Plastic Limit (PL) = 19.35 %
Plasticity Index (PI) = LL - PL = 4.25 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.25 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.7 20.1
19.5 23.4
21.3 24.5
22.2 25.4

23.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 24.9 26.2 -
Penetration in (mm) 15.9 18.7 21.2 22.1 -

Liquid Limit (LL) = 24.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 20.5 -
Plastic Limit (PL) = 20 %
Plasticity Index (PI) = LL - PL = 4%
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.00 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.9 20.3
18.7 22.4
21.2 24.9
22.1 26.2

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 25.3 26.1 -
Penetration in (mm) 16.9 18.7 21.2 22.1 -

Liquid Limit (LL) = 23.80 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.8 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.2 20.5 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 4.95 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.95 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.9 20.3
18.7 22.4
21.2 25.3
22.1 26.1

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.4 21.9 24.8 25.8 -
Penetration in (mm) 17.7 18.8 20.7 21.9 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.9 19.8 -
Plastic Limit (PL) = 19.35 %
Plasticity Index (PI) = LL - PL = 4.15 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.15 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.7 20.4
18.8 21.9
20.7 24.8
21.9 25.8

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.7 23.2 24.1 25.7 -
Penetration in (mm) 17.5 19.8 20.7 22.5 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.6 19.8 -
Plastic Limit (PL) = 18.7 %
Plasticity Index (PI) = LL - PL = 4.6 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.60 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.5 20.7
19.8 23.2
20.7 24.1
22.5 25.7

23.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 23.9 25.9 -
Penetration in (mm) 16.6 17.9 19.1 20.3 -

Liquid Limit (LL) = 25.40 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 25.4 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 21.2 19.9 -
Plastic Limit (PL) = 20.55 %
Plasticity Index (PI) = LL - PL = 4.85 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.85 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.6 20.5
17.9 22.6
19.1 23.9
20.3 25.9

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 22.2 23.5 25.5 -
Penetration in (mm) 16.9 18.2 19.4 20.6 -

Liquid Limit (LL) = 24.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.5 21.1 -
Plastic Limit (PL) = 19.8 %
Plasticity Index (PI) = LL - PL = 4.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.9 20.1
18.2 22.2
19.4 23.5
20.6 25.5

22.8
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 22.6 24.9 25.9 -
Penetration in (mm) 17.7 19.1 20.5 21.5 -

Liquid Limit (LL) = 24.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.1 19.5 -
Plastic Limit (PL) = 19.3 %
Plasticity Index (PI) = LL - PL = 4.7 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.70 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.7 20.5
19.1 22.6
20.5 24.9
21.5 25.9

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 24.9 26.5 -
Penetration in (mm) 17.3 19.2 21.2 22.8 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.9 18.8 -
Plastic Limit (PL) = 18.35 %
Plasticity Index (PI) = LL - PL = 4.95 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.95 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.3 20.3
19.2 22.4
21.2 24.9
22.8 26.5

23.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 25.1 26.5 -
Penetration in (mm) 16.9 18.7 21.7 22.6 -

Liquid Limit (LL) = 23.60 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.9 -
Plastic Limit (PL) = 19.7 %
Plasticity Index (PI) = LL - PL = 3.9 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.90 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.9 20.3
18.7 22.4
21.7 25.1
22.6 26.5

23.6
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.3 22.4 25.1 26.5 -
Penetration in (mm) 16.5 18.2 20.9 22.1 -

Liquid Limit (LL) = 24.20 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.8 19.5 -
Plastic Limit (PL) = 19.15 %
Plasticity Index (PI) = LL - PL = 5.05 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.05 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.5 20.3
18.2 22.4
20.9 25.1
22.1 26.5

23.6
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.9 21.9 24.1 25.9 -
Penetration in (mm) 15.2 17.6 19.5 21.3 -

Liquid Limit (LL) = 24.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.5 19.9 -
Plastic Limit (PL) = 19.7 %
Plasticity Index (PI) = LL - PL = 4.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.2 19.9
17.6 21.9
19.5 24.1
21.3 25.9

23.0
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.2 20.9 22.5 25.1 -
Penetration in (mm) 15.8 17.6 18.9 21.5 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 19.9 -
Plastic Limit (PL) = 19.05 %
Plasticity Index (PI) = LL - PL = 4.45 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.45 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.8 19.2
17.6 20.9
18.9 22.5
21.5 25.1

21.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.3 22.2 24.2 26.8 -
Penetration in (mm) 16.3 18.4 20.5 22.5 -

Liquid Limit (LL) = 23.80 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.8 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.8 19.5 -
Plastic Limit (PL) = 19.15 %
Plasticity Index (PI) = LL - PL = 4.65 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.65 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.3 19.3
18.4 22.2
20.5 24.2
22.5 26.8

23.1
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.3 22.5 24.2 26.8 -
Penetration in (mm) 16.8 19.1 20.5 22.1 -

Liquid Limit (LL) = 23.70 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.7 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.5 19.1 -
Plastic Limit (PL) = 18.8 %
Plasticity Index (PI) = LL - PL = 4.9 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.90 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.8 19.3
19.1 22.5
20.5 24.2
22.1 26.8

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.2 20.8 22.5 25.1 -
Penetration in (mm) 17.8 18.5 19.2 20.5 -

Liquid Limit (LL) = 24.10 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.8 19.3 -
Plastic Limit (PL) = 19.55 %
Plasticity Index (PI) = LL - PL = 4.55 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.55 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.8 19.2
18.5 20.8
19.2 22.5
20.5 25.1

21.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.5 20.6 21.8 24.6 -
Penetration in (mm) 15.8 17.6 18.8 21 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.5 18.5 -
Plastic Limit (PL) = 18 %
Plasticity Index (PI) = LL - PL = 5.3 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.30 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.8 18.5
17.6 20.6
18.8 21.8
21 24.6

21.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.4 22.2 24.3 26.8 -
Penetration in (mm) 16.7 18.4 20.2 22.4 -

Liquid Limit (LL) = 23.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.4 19.3 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 5.05 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.05 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.7 19.4
18.4 22.2
20.2 24.3
22.4 26.8

23.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.4 22.3 24.5 26.4 -
Penetration in (mm) 17.6 19.4 20.8 22.4 -

Liquid Limit (LL) = 23.30 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.3 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.2 18.6 -
Plastic Limit (PL) = 17.9 %
Plasticity Index (PI) = LL - PL = 5.4 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.40 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.6 20.4
19.4 22.3
20.8 24.5
22.4 26.4

23.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 17.2 21.3 24.2 26.8 -
Penetration in (mm) 15.5 18.6 20.4 22.3 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.6 20.3 -
Plastic Limit (PL) = 19.95 %
Plasticity Index (PI) = LL - PL = 3.55 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.55 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.5 17.2
18.6 21.3
20.4 24.2
22.3 26.8

22.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.3 22.5 23.8 26.8 -
Penetration in (mm) 16.8 19.1 20.2 22.1 -

Liquid Limit (LL) = 23.70 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.7 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.3 20.1 -
Plastic Limit (PL) = 19.2 %
Plasticity Index (PI) = LL - PL = 4.5 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.50 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.8 19.3
19.1 22.5
20.2 23.8
22.1 26.8

23.1
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.1 23.4 25.1 26.2 -
Penetration in (mm) 15.3 19.2 21.1 22.2 -

Liquid Limit (LL) = 24.20 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 24.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 19.5 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 5.35 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.35 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.3 20.1
19.2 23.4
21.1 25.1
22.2 26.2

23.7
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 24.2 26.2 27.1 28.3 -
Penetration in (mm) 17.6 22.5 25.3 27.6 -

Liquid Limit (LL) = 25.10 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 25.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.6 20.3 -
Plastic Limit (PL) = 19.95 %
Plasticity Index (PI) = LL - PL = 5.15 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.15 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

17.6 24.2
22.5 26.2
25.3 27.1
27.6 28.3

26.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 17.2 21.3 24.2 26.8 -
Penetration in (mm) 15.5 18.6 20.4 22.3 -

Liquid Limit (LL) = 23.50 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.6 20.3 -
Plastic Limit (PL) = 19.95 %
Plasticity Index (PI) = LL - PL = 3.55 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.55 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.5 17.2
18.6 21.3
20.4 24.2
22.3 26.8

22.4
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18 20.4 22.3 24.6 -
Penetration in (mm) 16.3 18.4 20.5 22.5 -

Liquid Limit (LL) = 21.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 21.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.5 17.3 -
Plastic Limit (PL) = 17.4 %
Plasticity Index (PI) = LL - PL = 4.5 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.50 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

23

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.3 18
18.4 20.4
20.5 22.3
22.5 24.6

21.3
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 15.8 18.4 22.3 24.6 -
Penetration in (mm) 15.2 17.6 20.5 22.8 -

Liquid Limit (LL) = 21.40 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 21.4 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.8 15.6 -
Plastic Limit (PL) = 16.7 %
Plasticity Index (PI) = LL - PL = 4.7 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.70 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

15.2 15.8
17.6 18.4
20.5 22.3
22.8 24.6

20.3
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.5 21.1 25.3 28.2 -
Penetration in (mm) 16.4 18.2 22.3 25.1 -

Liquid Limit (LL) = 22.70 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 22.7 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 16.5 18.4 -
Plastic Limit (PL) = 17.45 %
Plasticity Index (PI) = LL - PL = 5.25 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.25 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

Checked By : Tested by:


penetration
in (mm) - Y- Moisture %
X-axis
axis

16.4 18.5
18.2 21.1
22.3 25.3
25.1 28.2

23.3
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.4 20.3 23.1 24.8 -
Penetration in (mm) 14.9 16.8 19.2 20.8 -

Liquid Limit (LL) = 23.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.5 19.2 -
Plastic Limit (PL) = 18.85 %
Plasticity Index (PI) = LL - PL = 5.05 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.05 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

22

21

20

19

18

17

16

15

14
15 16 17 18 19 20 21 22 23 24 25 26

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

14.9 18.4
16.8 20.3
19.2 23.1
20.8 24.8

21.7
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 21.2 22.8 24.1 26.2 -
Penetration in (mm) 17.5 19.6 22.3 25.8 -

Liquid Limit (LL) = 22.90 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 22.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.4 19.5 -
Plastic Limit (PL) = 18.45 %
Plasticity Index (PI) = LL - PL = 4.45 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.45 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

17.5 21.2
19.6 22.8
22.3 24.1
25.8 26.2

23.6
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.5 21.8 24.5 28.7 -
Penetration in (mm) 18.6 20 22.3 24.8 -

Liquid Limit (LL) = 22.00 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 22 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 18.2 16.5 -
Plastic Limit (PL) = 17.35 %
Plasticity Index (PI) = LL - PL = 4.65 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.65 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

18.6 20.5
20 21.8
22.3 24.5
24.8 28.7

23.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.2 20.7 25.3 26.9 -
Penetration in (mm) 16.3 18.6 24.5 26.3 -

Liquid Limit (LL) = 21.6 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 21.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 15.8 15.9 -
Plastic Limit (PL) = 15.85 %
Plasticity Index (PI) = LL - PL = 5.75 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.75 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

16.3 18.2
18.6 20.7
24.5 25.3
26.3 26.9

22.8
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.2 22.2 26.8 27.4 -
Penetration in (mm) 18.5 20.3 26.4 28.3 -

Liquid Limit (LL) = 21.6 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 21.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 16.8 17.4 -
Plastic Limit (PL) = 17.1 %
Plasticity Index (PI) = LL - PL = 4.5 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.50 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

18.5 20.2
20.3 22.2
26.4 26.8
28.3 27.4

24.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 22.2 26.5 27.3 28.4 -
Penetration in (mm) 17.5 24.8 26.9 28.6 -

Liquid Limit (LL) = 23.6 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.6 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.1 19.3 -
Plastic Limit (PL) = 18.2 %
Plasticity Index (PI) = LL - PL = 5.4 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.40 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

17.5 22.2
24.8 26.5
26.9 27.3
28.6 28.4

26.1
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.6 22.5 24.8 26.3 -
Penetration in (mm) 19.5 22.4 26.8 27.4 -

Liquid Limit (LL) = 20.1 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 20.1 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 16.2 15.4 -
Plastic Limit (PL) = 15.8 %
Plasticity Index (PI) = LL - PL = 4.3 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.30 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

19.5 19.6
22.4 22.5
26.8 24.8
27.4 26.3

23.3
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 18.5 24.7 26.3 28.4 -
Penetration in (mm) 18.2 22.6 25 27.3 -

Liquid Limit (LL) = 20.8 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 20.8 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 15.3 15.8 -
Plastic Limit (PL) = 15.55 %
Plasticity Index (PI) = LL - PL = 5.25 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 5.25 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

18.2 18.5
22.6 24.7
25.0 26.3
27.3 28.4

24.5
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.7 23.4 27.4 29.4 -
Penetration in (mm) 16.4 20.4 24.5 27.1 -

Liquid Limit (LL) = 23.4 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.4 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.8 19.3 -
Plastic Limit (PL) = 19.55 %
Plasticity Index (PI) = LL - PL = 3.85 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.85 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

16.4 20.7
20.4 23.4
24.5 27.4
27.1 29.4

25.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.7 23.4 27.4 29.4 -
Penetration in (mm) 16.2 20.4 24.5 27.1 -

Liquid Limit (LL) = 23.5 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 23.5 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.2 19.5 -
Plastic Limit (PL) = 19.35 %
Plasticity Index (PI) = LL - PL = 4.15 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 4.15 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
18 19 20 21 22 23 24 25 26 27 28 29 30

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

16.2 20.7
20.4 23.4
24.5 27.4
27.1 29.4

25.2
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 19.5 21.7 24.5 25.8 -
Penetration in (mm) 15.6 18.4 21.6 24.1 -

Liquid Limit (LL) = 22.9 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 22.9 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 19.4 18.8 -
Plastic Limit (PL) = 19.1 %
Plasticity Index (PI) = LL - PL = 3.8 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.80 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

25

24

23

22

21

20

19

18

17

16

15

14
18 19 20 21 22 23 24 25 26 27

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

15.6 19.5
18.4 21.7
21.6 24.5
24.1 25.8

22.9
Test for Granular Sub Base
Atterberg Limit Test
Sample no. Date of testing:
Name of quarry/Location Type of soil : GSB

Determination of Liquid Limit (LL)


1 2 3 4 Remarks
Moisture Content % 20.9 22.7 24.7 26.7 -
Penetration in (mm) 19.2 22.4 24.3 26.3 -

Liquid Limit (LL) = 21.2 %


Layer Value Permissible Limit Whether conform to the
precribed limit (Yes/No.)

GSB 21.2 -
if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

Determination of Plastic Limit (PL)


1 2 Remarks
Moisture Content % 17.5 18.5 -
Plastic Limit (PL) = 18 %
Plasticity Index (PI) = LL - PL = 3.2 %
Whether conform to the
Layer Value Permissible Limit precribed limit (Yes/No.)

GSB 3.20 <6 Yes


if Results don’t conform to the prescribed limits. Non conformance report will be issued by PIU . The
reference of the page no. of this register on which ono confermence reports copy preserved page no.
…………………date of issue…………………..

27
26
25
24
23
22
21
20
19
18
17
16
15
14
18 19 20 21 22 23 24 25 26 27 28

Checked By : Tested by:


penetration
Moisture %
in (mm) - Y-
axis X-axis

19.2 20.9
22.4 22.7
24.3 24.7
26.3 26.7

23.8