Sikagard®-63 N: Product Data Sheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

PRODUCT DATA SHEET

Sikagard®-63 N
2-PART EPOXY PROTECTIVE COATING

DESCRIPTION ENVIRONMENTAL INFORMATION


Sikagard®-63 N is a two part, rigid, total solid, col- Conformity with LEED v2009 IEQc 4.2: Low-Emitting
oured epoxy resin based protective coating. Materials - Paints and Coatings

USES APPROVALS / STANDARDS


Sikagard®-63 N may only be used by experienced pro- Coating for concrete protection according the require-
fessionals. ments of EN 1504-2/2004, DoP
▪ Chemical resistant protective layer on concrete, 0206060100300000011008, certified by FPC Notified
stone, cementitious mortars and renderings, epoxy Body and provided with CE-Marking.
cement, epoxy resin based products and steel
▪ Lining in storage tanks and silos
▪ Anti-corrosion coating on steel in food processing
plants, sewage works, farms, agricultural enterprises,
chemical and pharmaceutical facilities and beverage
industry

CHARACTERISTICS / ADVANTAGES
▪ Solvent free
▪ Good mechanical and chemical resistance
▪ High build
▪ Impervious to liquids
▪ Easy to mix and to apply

PRODUCT INFORMATION
Chemical Base Epoxy resin
Packaging Part A 8.70 kg drums
Part B 1.3 kg drums

Appearance / Colour RAL 7032 (pebble grey), other on request


Shelf Life 12 months from date of production
Storage Conditions The packaging must be stored properly in original, unopened and undam-
aged sealed packaging, in dry conditions at temperatures between +5 °C
and +30 °C. Protected from direct sunlight.

Product Data Sheet


Sikagard®-63 N
November 2018, Version 02.01
020606010030000001

1/3
Density Mixed resin approx. 1.35 kg/l (EN ISO 2811-1)
Density values determined at +23 °C
Solid Content ~100 %

TECHNICAL INFORMATION
Tensile Adhesion Strength > 1.5 N/mm² to concrete (ISO 4624)
>15 N/mm² to steel (EN 24624)
>10 N/mm2 to aluminium (EN 24624)

Chemical Resistance For further information please contact Sika Technical Service.
Thermal Resistance Exposure Dry heat
Permanent +40 °C
max. 3 days +60 °C

Diffusion Resistance to Water Vapour µH2O ~ 100 000 (EN ISO 7783-1)

APPLICATION INFORMATION
Mixing Ratio Part A : Part B = 83 : 17 by weight
Consumption ~0.15 kg/m² per layer
Layer Thickness ~0.1 mm per layer
Ambient Air Temperature +10 °C min. / +30 °C max.
Relative Air Humidity < 80 %
Substrate Temperature +10 °C min. / +40 °C max.
Minimum 3 °C above dew point, beware of condensation
Pot Life Temperature Time
+10 °C ~30 min
+20 °C ~20 min
+30 °C ~10 min

Waiting Time / Overcoating Temperature Min. Max. Full Cure


+10 °C ~9 hours ~3 days ~14 days
+20 °C ~5 hours ~2 days ~9 days
+30 °C ~4 hours ~1 day ~5 days

APPLICATION INSTRUCTIONS the product, preferably by brush and/or vacuum.


Open voids and blowholes need to be closed with a
SUBSTRATE QUALITY suitable Sika® pore filling mortar. The roughness of the
substrate needs to be levelled with a suitable Sika®
The substrate must be sound, clean, dry, free from rendering and levelling mortar.
contaminants such as dirt, grease, oil, old coatings, re-
lease agents, laitance and other adhesion preventing Steel Surface
or influencing substances. Steel surface must be prepared mechanically using ab-
On high absorbent, non-sound, contaminated, not ce- rasive blast cleaning. The level SSPC-SP 10 “near white
ment based substrates precautions have to be taken metal blast cleaned” or level Sa 2 ½ according to ISO
and a suitable primer has to be used. EN 12944-4 has to be achieved. Welds and joints have
to be prepared according to EN 14879, part 1. After
SUBSTRATE PREPARATION blast cleaning remove all dust dirt and blasting materi-
al. In order to maintain the surface conditions after
Concrete Substrates
blast cleaning air-conditioning is recommended.
Concrete substrate must be prepared mechanically to
achieve an open textured surface. MIXING
Weak areas in the substrate must be removed and sur-
face defects such as blowholes and voids must be fully Prior to mixing stir part A mechanically. When all of
exposed. part B has been added to part A mix continuously for 3
All dust, loose and friable material must be com- minutes until a uniform mix has been achieved. Use a
pletely removed from all surfaces before application of low speed electrical stirrer (300–400 rpm) to avoid air

Product Data Sheet


Sikagard®-63 N
November 2018, Version 02.01
020606010030000001

2/3
entrapment. To ensure proper mixing pour material in- ECOLOGY, HEALTH AND SAFETY
to a clean container and stir again.
For information and advice on the safe handling, stor-
APPLICATION age and disposal of chemical products, users shall refer
Apply by brush, roller or airless spray. to the most recent Safety Data Sheet (SDS) containing
physical, ecological, toxicological and other safety-re-
CLEANING OF TOOLS lated data.

Clean all tools with Thinner C immediately after use. DIRECTIVE 2004/42/CE - LIMITATION OF EMISSIONS
Hardened and/or cured material can only be removed OF VOC
mechanically.
According to the EU-Directive 2004/42, the maximum
allowed content of VOC (Product category IIA / j type
LIMITATIONS sb) is 500 g/l (Limits 2010) for the ready to use
▪ Do not apply Sikagard®-63 N on moist substrates. product. The maximum content of Sikagard®-63 N is
▪ Sag resistance on vertical surface is < 100 μm. <500 g/l VOC for the ready to use product.
▪ Sikagard®-63 N cannot be used to produce glass fibre
reinforced linings. LEGAL NOTES
▪ Freshly applied Sikagard®-63 N must be protected
from rain, condensation and water for at least 24 The information, and, in particular, the recommenda-
hours. tions relating to the application and end-use of Sika
▪ For exact colour matching ensure using material from products, are given in good faith based on Sika's cur-
the same control batch numbers. rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
BASIS OF PRODUCT DATA tions. In practice, the differences in materials, sub-
All technical data stated in this Product Data Sheet are strates and actual site conditions are such that no war-
based on laboratory tests. Actual measured data may ranty in respect of merchantability or of fitness for a
vary due to circumstances beyond our control. particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
LOCAL RESTRICTIONS mendations, or from any other advice offered. The
Please note that as a result of specific local regula- user of the product must test the product’s suitability
tions the declared data for this product may vary from for the intended application and purpose. Sika re-
country to country. Please consult the local Product serves the right to change the properties of its
Data Sheet for the exact product data. products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.

Sika India Pvt. Ltd.


620, Diamond Harbour Road
Commercial Complex II
Kolkata - 700 034
Tel : +91 33 24472448
Fax : +91 33 23978688
Mail : info.india@in.sika.com

Sikagard-63N-en-IN-(11-2018)-2-1.pdf

Product Data Sheet


Sikagard®-63 N
November 2018, Version 02.01
020606010030000001

3/3

You might also like