Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

2009 IITA International Conference on Control, Automation and Systems Engineering

Application of Raman Spectroscopy to Detecting Organic Contaminant in Water

Gang Li
Faculty of Mechanical and Electronic Information
China University of Geosciences
Wuhan 430074, China
ligang_chn@yahoo.com.cn

Minghong Chen
College of High Vocational Education
Central China Normal University
Wuhan 430079, China
350159311@qq.com

Tianyun Wei
GHT
guangzhou 510663, China
108711299@qq.com

Abstract—Organic contaminants are harmful to body health, Raman spectroscopy may be a potential alternative of IR
and are usually contained in waste water, so it is necessary to absorption technique, because it has many advantages in
determine and monitor them. The demand for real-time analyzing aqueous solutions and organic matter [4-12].
analysis and online examination of organic contaminants in Raman spectrum of water is so weak that Raman spectra of
water has presented a challenge to analytical and physical organic contaminants in waste water are unaffected by
chemist. Raman Spectroscopy is a molecular vibrational Raman spectrum of water. Furthermore, Raman
spectroscopic technique, and Raman effect is caused by spectroscopy requires little or no sample preparation. Most
interactions of molecule and photon and shows the information importantly, the intensity of Raman spectra of solute is
in molecules. Because the Raman spectra of different molecules
directly proportional to its concentration. It is very easy to
are much more distinct, they provides characteristic of the
molecule. Especially, Raman spectra of the solutes are
qualitative analyze aqueous solutions. This paper analyzed
unaffected by the water, therefore the weak scattering of water the Raman spectra of toluene, ethylbenzene, o-xylene, m-
makes the technique well suited to analyzing aqueous xylene and p-xylene in detail, and assigned Raman identified
contaminants. The paper firstly introduced Raman spectra of their mixture.
spectroscopy, and then analyzed and assigned the Raman
spectra of five kinds of organic contaminants and their
II. EXPERIMENTAL
mixture. The results showed that Raman spectroscopy is a
powerful technique for analyzing aqueous solutions of organic A. Instrumentation
contaminants. The Raman spectra in this paper were obtained using
Raman Systems R-3000 spectrometer (Boston Advanced
Keywords- water analysis; organic contaminant; Raman Technologies, Marlboro, MA, USA) with spectral resolution
spectroscopy; frequency shift 10 cm–1. All experiments were carried out under a room
temperature.
I. INTRODUCTION
B. Materials and Reagents
Water environment is increasingly contaminated by All the chemicals used were of analytical reagent grade.
organic pollutants in recent years because of agricultural Toluene of 99% purity, ethylbenzene of 98% purity, o-
fertilizers [1, 2]. It is essential to determine and monitor the xylene of 99% purity, m-xylene of 99% purity, and p-xylene
organic contaminants such as benzene derivatives in waste of 98% purity were provided by Chemical Reagent Company
water. The IR spectroscopy are widely applied to analyze Ltd. of National Leechdom Group (Shanghai, China).
organic contaminants [3]. However, the absorption of the
aqueous solvent is so intense that it becomes difficult to III. RESULTS AND ANALYSIS
analyze the solute in the water by IR absorption. The
analysis of organic contaminants in aqueous solutions has Raman spectra of toluene, ethylbenzene, o-xylene, m-
presented a new challenge to analytical and physical chemist. xylene and p-xylene were shown in Fig. 1 A-E, respectively.

978-0-7695-3728-3/09 $25.00 © 2009 IEEE 493


DOI 10.1109/CASE.2009.149
Benzene's derivatives

996.5

1202.3
729.3

1027.5
824.6
Intensity (a. u.)

718.9
515.1

1047.4
784
535.1

1377.7

1605.4
806.1
765.6
577.9

1220.7
616.9

1175.9

1586.1
1446.5
639

1153.1
964.8

1247.4
1088.5

1314.7
600 800 1000 1200 1400 1600
-1
Raman Shift (cm )
Figure 3. Raman spectrum of mixture of toluene, ethylbenzene, o-xylene,
m-xylene and p-xylene after polynomial fit.

Raman peaks of the mixture were assigned in Table I.


TABLE I. ASSIGNMENT OF RAMAN PEAKS OF THE MIXTURE OF
TOLUENE, ETHYLBENZENE, O-XYLENE, M-XYLENE AND P-XYLENE (RS:
RAMAN SHIFT; RI: RAMAN INTENSITY)
Figure 1. Raman spectra of (A) toluene, (B) ethylbenzene, (C) o-xylene,
Peak Component assignment
(D) m-xylene and (E) p-xylene.
[RS (cm-1), RI a] [RS (cm-1), RI a]
515.1, s toluene (517.5, s)
From Fig. 1 (A) and (B), it was clear that most Raman 535.1, s m-xylene (533.3, s)
peaks of toluene and ethylbenzene were different in both 577.9, s o-xylene (577.8, s)
Raman shifts and intensities, The same is true of xylene. 616.9, s toluene (618, m),
The mixture of toluene, ethylbenzene, o-xylene, m- ethylbenzene (616.6, s);
xylene, p-xylene, ethano and water was used to simulated the m-xylene (616.6, vw)
639, s p-xylene (639.6, s)
waste water. It’s Raman spectrum was shown in Fig. 2 (A). 718.9, s m-xylene (721.6, s);
Raman spectrum of ethano and water was removed from that p-xylene (717.2, vw)
of the mixture, as was shown in Fig. 2 (B). Raman peaks 729.3, s toluene (727.3, vw);
fitted by polynomial were presented in Fig. 3. o-xylene (728.8, s)
765.6, s ethylbenzene (763.3, s);
m-xylene (763.2, vw)
784, s toluene (781.9, s)
806.1, s p-xylene (819.4, s)
824.6, s p-xylene (819.4, s);
o-xylene (822.2, vw)
964.8, m ethylbenzene (963, m)
996.5, vs toluene (998.9, s);
ethylbenzene(998.9,vs);
o-xylene (981.7, s);
m-xylene (994.7, vs);
p-xylene (994.7, vw)
1027.5, vs toluene (1026.3, s);
ethylbenzene (1026.3, s);
m-xylene (1029.2, m);
p-xylene (1030.6, vw)
1047.4, s ethylbenzene (1059.3, m);
o-xylene (1047.9, s)
1088.5, w m-xylene (1090.9, w)
1153.1, m toluene (1152.8, m);
ethylbenzene (1152.9, m);
o-xylene (1154.2, w)
1175.9, m toluene (1177.2, m);
ethylbenzene (1176.4, m);
m-xylene (1167.2, w);
p-xylene (1178.7, m)
1202.3, vs toluene (1207.4, s);
ethylbenzene (1198, s);
Figure 2. Raman spectrum of mixture of toluene, ethylbenzene, o-xylene,
m-xylene (1194.4, vw);
m-xylene and p-xylene. (A) before and (B) after removed spectrum of
p-xylene (1202.1, vs)
water and ethanol.

494
1220.7, s o-xylene (1220.3, s) University. The authors would like to thank very much all
1247.4, m ethylbenzene (1240.2, vw); the staffs of the laboratory for their assistance.
m-xylene (1247.7, m)
1314.7, w ethylbenzene (1322.4, w); REFERENCES
p-xylene (1309.5, w)
1377.7, s toluene (1377, m); [1] J. D. Berset and R. Holzer, “Organic micropollutants in Swiss
ethylbenzene (1374.1, vw); agriculture: distribution of polycyclic aromatic hydrocarbons ( PAH)
o-xylene (1381.3, s); and polychlorinated biphenyls ( PCB) in soil , liquid manure , sewage
m-xylene (1377, m); sludge and compost samples: a comparative study,” International
p-xylene (1375.6, s) Journal of Environ. Anal. Chem. vol. 59, Apr. 1995 , pp. 145-165,
1446.5, s toluene(1441.7, vw); doi:10.1080/03067319508041324.
ethylbenzene(1446, m); [2] A. M. Kipopoulou, E. Manoli and C. Samara, “Bioconcentration of
o-xylene(1447.5, m); polycyclic aromatic hydrocarbons in vegetables grown in an
m-xylene(1446, w); industrial area,” Environ. Pollut. vol. 106, Sep.1999, pp. 369-380,
p-xylene(1447.4, m) doi: 10.1016/S0269-7491(99)00107-4.
1586.1, s toluene(1582.4, m), [3] Yonggang Shi, XinLu Feng and Ping Sun, “Rapid Identification of
ethylbenzene(1581.4, m); Organic Contaminants in Waste Water by Near Infrared
o-xylene(1581.1, m); Spectroscopy,” Chinese Journal of Spectroscopy Laboratory, vol. 22,
m-xylene(1590.6, m); May, 2005, pp. 575-577. doi: CNKI:SUN:GPSS.0.2005-03-036.
p-xylene(1576.8, w) [4] Changhu Yang, Xiaoying Zeng and Jiaxin Liao, “study on Raman
1605.4, s toluene(1602.4, s); spectrum in comparing impurity concentration in water,”
ethylbenzene(1602.8, m); Environmental Monitoring in China, vol. 24, Feb. 2008, pp. 21-23,
o-xylene(1604.2, m); doi: CNKI:SUN:IAOB.0.2008-01-006.
m-xylene(1609.6, m);
[5] Shona Stewart, John S. Maier and Patrick J. Treado. Water quality
p-xylene(1615.6, m)
monitoring by Raman spectral analysis. United States Patent : US 6
a
vs: very strong; s: strong; m: medium; w: weak; vw: very weak. ,950 ,184 ,Sep. 27 ,2005.
[6] Yongzhou Zhao, Zuowei Li, Shuqin Gao, Chunnian Ren, Guohui Lu
As shown in Table I, the characteristic Raman peaks of and Yingnin Yu, “Ultra-trace analysis of biological molecules in
the five kinds of organic contaminant were presented in water by means of the resonance Raman spectra in liquid-core optical
Raman spectrum of the mixture. Raman peaks at 515.1 cm-1 fiber,” Laser Technology, vol. 28 Oct. 2004, pp. 491-493, doi:
CNKI:SUN:JGJS.0.2004-05-013.
and 784 cm-1 could be assigned to toluene; the 1047.4 cm-1
[7] Junlian Qiao, Guanghong Zheng and Fengting Li, “Determination of
and 765.6 cm-1 Raman peaks could be dued to ethylbenzene; Trance Pesticide in Water by Surface Enhanced Raman
the peaks at 577.9 cm-1 and 1220.7 cm-1 were both attributed Spectroscopy,” Chemistry, vol. 6 Jun. 2006, pp. 462-464, doi:
to o-xylene; Raman peaks at 535.1 cm-1 and 964.8 cm-1 were CNKI:SUN:HXTB.0.2006-06-013.
assigned to m-xylene; Raman peaks at 639 cm-1 and 806.1 [8] Yulan Hao and Gangsheng Zhang, “In situ Resonance Raman Spectra
cm-1 were dued to ethylbenzene. of Organic Pigments in Freshwater Cultured Pearls,” Spectroscopy
and Spectral Analysis, vol. 26, Jan. 2006, pp. 78-80, doi:
IV. CONCLUSION CNKI:SUN:GUAN.0.2006-01-021.
[9] J. R. Baena and B. Lendl, “ Raman spectroscopy in chemical
As a vibrational spectroscopy, Raman spectrum is a bioanalysis,” Current Opinion in Chemical Biology, vol. 8, Oct. 2004,
precise spectral fingerprint of the molecule, and different pp. 534-539, doi: 10.1016/j.cbpa.2004.08.014.
samples’ Raman spectra are much distinct, so Raman [10] S. R. Ahmad and V. G. Foster, “Pre-resonance Raman scattering in
spectroscopy is a perfect analytical technology. More nitrobenzene vapour,” Journal of Raman Spectroscopy, vol. 31, Nov.
importantly, because Raman spectrum of water is very weak, 2000, pp. 1023–1028, doi: 10.1002/1097-4555 (200011) 31:11
<1023: AID-JRS639> 3.0.CO;2-2.
Raman spectroscopy will be more widely employed to
analyze organic contaminants in waste water. [11] Horst B. Lueck, Tim C. Swinney, Bruce S. Hudson and Donald M.
Friedrich, “Resonance Raman studies of benzene derivatives with
This paper assigned Raman spectrum of the mixture of strong conjugation: nitrile substitution,” Chemical Physics Letters,
toluene, ethylbenzene, o-xylene, m-xylene and p-xylene in vol. 258, Aug. 1996, pp. 80-86, doi: 10.1016/0009-2614(96)00644-6.
detail, and the experimental results demonstrated that Raman [12] Jose M. Alia, Howell G. M. Edwards and Breda M. Kiernan,
spectroscopy is a particularly powerful technique for “Hydrogen bonding in benzenesulfonic and 4-toluenesulfonic acids
aqueous solutions of organic contaminants. dissolved in N,N’-dimethylformamide: an FT-Raman study,” Journal
of Raman Spectroscopy, vol. 35 Feb. 2004, pp. 111–118, doi:
ACKNOWLEDGMENTS 10.1002/jrs.1112.

This work was performed in the photoelectron and


information engineering laboratory of Central China Normal

495