Professional Documents
Culture Documents
Kyowa Accel
Kyowa Accel
$FFHOHUDWLRQ
7UDQVGXFHUV
2-117 Acceleration Transducers
■Acceleration Transducers
Kyowa's strain-gage acceleration transducers convert
TRANSDUCERS
Features
■Principle of Acceleration Transducers ●There are 2 marks which indicates the sensitivity axis of
acceleration.
With the basic configuration shown below, acceleration (1) When the arrow which indicates the sensitivity axis is "+←
initiates inertia force to the weight and deforms the leaf → -";In case a acceleration transducers is set as ”+” points the
spring. The strain gage adhered to the leaf spring detects earth's center (Direction for Acceleration of Gravity),+1 G is
the displacement of the leaf spring as a strain quantity output when any load is not added. As the output is based on
proportional to the acceleration. The strain-gage signal Acceleration of Gravity, the relationship between input condition
is amplified to enable acceleration measurement. An and output of acceleration is shown on the following table.
advantageous feature of this configuration is to enable the
Acceleration Impact Rotation It agrees with a
transducer to respond to static acceleration at DC. motion of a plumb
Center of bob and outputs
rotation
1 G at the time
Acceleration of stillness.
Weight Strain gage Gravitational
conditions
Sensitivity direction
acceleration is
to be basic
Acceleration
Transducers
Leaf spring Polarity of
output
Outline
(2) When the arrow which indicates the sensitivity axis is " ↑ " ;
Arrows on the case “ ”
General Fig. 1 Basic Configuration of strain-gage Acceleration Transducer Acceleration Impact Rotation
The arrow on
Center of the the case is
Acceleration rotation
in accordance
Piezoelectric conditions with the
direction of
■Installation and Removal acceleration.
Polarities of output
Gyro
Install the acceleration transducer aligning the sensitive axis
("+ ← →-" marked on the transducer) with the acceleration
Note: Please check instruction Acceleration transducers are
measuring direction.
installed to objects by adhesives like CC-33A, bolts, or mount
bases. To measure correctly, mount acceleration transducers
following instruction manual. When removing acceleration
transducers, take sufficiently care to avoid excessive impact or
force resulting in damaging transducers.
Measurement of
acceleration
Output Ratio (%) Output Ratio (%)
Screw/Bolt
Acceleration
Measurement of acceleration
Bonded
in vertical direction
Acceleration
120
(CC-33A)
(Measuring range in the up direction 110
is narrower by 9.807 m/s2 (1 G).) 100
90
Fig. 2 Installing or Removing Acceleration Transducers 80
AS-50HB 10 2 Frequency (Hz) 10 3
2-117
Acceleration Transducers Measurement Examples
2-118
TRANSDUCERS
●Vibration tests of goods during truck transportation
Universal Recorder
EDX-200A
Acceleration
Transducers
Outline
■Temperature Effect on Frequency Response ■Overload Considerations
To ensure flat frequency response characteristics, some Generally, the magnitude of acceleration is difficult to be
models of acceleration transducers have oil sealed inside. The grasped by human perception. If the transducer is dropped General
viscosity of the oil is adjusted to make the frequency response on the floor, it may easily sense acceleration exceeding
flat at 23°C. Changes in viscosity due to temperature changes 9807 m/s2 (1000 G) depending on the material of the
affect the frequency response and phase characteristics. floor. If a small-capacity acceleration transducer receives Piezoelectric
Though a silicone oil which the viscosity hardly changes an acceleration 10 times larger than the rated capacity, the
is adopted, the frequency response characteristics of the initial voltage unbalance changes outstandingly, thereby
transducer are affected by temperatures as shown in the making the transducer unusable due to disconnection of the
Gyro
figure below. Thus, for accurate measurement in a frequency gage, etc. Thus, the acceleration transducer must be handled
zone exceeding one-tenth the stated frequency response carefully
range, the temperature of the transducer should be kept
around 23°C. We assume 1 G = 9.807 m/s2 in this catalog.
33°C
+10%
Output Sensitivity (%)
23°C
100
−10% 13°C
−2°C
AS-50HB
100 1000
Frequency (Hz)
2-118
2-119
●Vibration tests on railway vehicle and truck
TRANSDUCERS
Small-sized Triaxial
Accelerometer
AMA-A
Universal Recorder
EDX-200A
Small-sized High
Frequency Response
Acceleration Transducer
ASH-A
Acceleration
Transducers
Memory Recorder/Analyzer
Outline EDX-5000A
General
●Vibration tests on various structures such as piers
Piezoelectric
Gyro
Memory Recorder/Analyzer
EDX-5000A
2-119
Acceleration Transducer Selection Chart 2-120
TRANSDUCERS
9.807 19.61 49.03 98.07 196.1 490.3 980.7 1961 4903 9807 Pages
Models (1 G) (2 G) (5 G) (10 G) (20 G) (50 G) (100 G) (200 G) (500 G) (1000 G)
Small-Large Capacity
Small-sized
Triaxial Yes Yes Yes Yes Yes 2-135
AMA-A
Large Capacity
Small-sized Yes Yes 2-134
AMAS-A
Medium Capacity
Small-sized Yes Yes Yes 2-122
AS-B
Small-
Medium Capacity
Yes Yes Yes Yes Yes 2-121
Small-sized AS-GA
Small Capacity Small-
Medium Capacity Yes Yes Yes Yes Yes 2-121
AS-GB
Large Capacity
Small-sized Yes Yes Yes Yes 2-124
ASH-A
High Medium Capacity
Frequency Yes Yes Yes 2-123
Response AS-HB
Large Capacity
Triaxial Yes Yes Yes Yes 2-127
ASHT-A
Small-sized,
Servo Type Output ±5 V FS Yes Yes Yes 2-129
ASQ-D
Medium Capacity
Triaxial Yes Yes Yes 2-126
AS-TB
Small-
Small-sized Medium Capacity
Triaxial Yes Yes Yes Yes Yes 2-125
AS-TG
Small-
Water Proof Medium Capacity Yes Yes Yes Yes Yes 2-128
ASW-A
5-22 5-25
ASM-A-ID
5-29
ASE-A ASDR-A-1K
ASM-1KCBV
5-23 5-26 5-30
2-120
2 AS-GA/GB
-121 Small-sized Small-capacity Acceleration Transducer
●9.807 to 196.1 m/s2
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more
Environmental Characteristics
Safe Temperature -15 to 65°C
Easy to use
Measuring instrument side: PRC03-12A10-7M
(Shield wire is not connected to the case.)
Suitable for measurement of
AS-GB Terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
vibration of model structures and Mechanical Properties
in the field of human engineering. Safe Overloads 300%
Frequency Response See table below.
Using a strain gage as the sensing element, AS-GA and Transverse Sensitivity 4% RO or less
AS-GB series acceleration transducers are designed Weight Approx. 15 g (AS-GA) (Excluding cable)
to measure small levels of acceleration. The compact Approx. 25 g (AS-GB) (Excluding cable)
& lightweight design makes them widely used for
Rated Capacity
measurement of vibration in small structures or scale Models
(Reference Value)
Frequency Response (At 23°C)
models as well as in the field of human engineering. AS-1GA, GB ±9.807 m/s2 (±1 G) DC to 40 Hz ±5%
AS-GA series comes with hermetic terminal and AS-GB AS-2GA, GB ±19.61 m/s2 (±2 G) DC to 60 Hz ±5%
series are integrated with cable. AS-5GA, GB ±49.03 m/s2 (±5 G) DC to 100 Hz ±5%
AS-10GA, GB ±98.07 m/s2 (±10 G) DC to 150 Hz ±5%
■Dimensions
AS-20GA, GB ±196.1 m/s2 (±20 G) DC to 250 Hz ±5%
(Note) To install AS-GB, use CC-33A adhesive or optional mount base
(See figures below).
Sensitive
Axis
(6) 3
(6) 3
General
2.5
5
32
14
Gyro 25
4.5
2.5
16 10
10.4
(25) 13.8
3
25
20
2 3.6
1
(6) 3
(6) 3
drilled hole
M4 2 2.2drilled hole
10 4 M2 d=3 10 φ4.2 counterbore
Mounting screw hole 2 2.2 drilled hole d=2.5
13.8
φ4.2 counterbore, d=2.5 2 M3 through hole
AS-GB 14 Connector plug
PRC03-12A10-7M DK-1A DK-1B
Weight: Approx. 2.5 g, Weight: Approx. 10 g,
aluminum aluminum
●Dynamic measurement
AS-GA/GB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10B: 0.5 mV/V ±25%
Environmental Characteristics
Safe Temperature -10 to 60°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is connected to the case.)
DC to 350 Hz ±5%
The compact and lightweight design barely disturbs AS-20B ±196.1 m/s2 (±20 G) DC to 500 Hz ±5%
AS-50B ±490.3 m/s2 (±50 G) DC to 1 kHz ±5%
the vibration mode of the object under measurement.
Easy installation is ensured using CC-33A adhesive.
Acceleration
Transducers
Outline
■Dimensions General
Piezoelectric
Sensitive Axis
16.5
Gyro
φ14
(0.5)
16
Connector plug
16 (25) PRC03-12A10-7M
●Dynamic measurement
AS-B
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A
→ 3-5 → 3-9 → 3-49 → 3-78 2-122
2 AS-HB
-123 Small-sized High Frequency Response Acceleration Transducer
●High frequency response ●98.07 to 490.3 m/s2
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10HB: 0.5 mV/V ±25%
Environmental Characteristics
Safe Temperature -15 to 65°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter
by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
Mechanical Properties
*TEDS-installed models are available. Inquiries are welcome. Safe Overloads 300%
Frequency Response See table below.
Transverse Sensitivity 2% RO or less
Weight Approx. 13 g (Excluding cable)
Highly accurate and reliable
Wide frequency response range Models
Rated Capacity
(Reference Value)
Frequency Response (At 23°C)
Acceleration
Transducers
Outline
General ■Dimensions
Piezoelectric
Sensitive Axis
16.5
Gyro
(φ14)
(0.5)
16
●Dynamic measurement
AS-HB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO/°C
Temperature Effect on Output Within ±1%/°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 120 Ω ±8.3%
Output Resistance 120 Ω ±8.3%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
*TEDS-installed models are available. Inquiries are welcome.
PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Acceleration
Transducers
Outline
■Dimensions General
Sensitive Axis
Piezoelectric
15.5
(0.5)
Gyro
φ12
(5.7)
14 (25)
Flat-to-flat
Connector plug
.2)
PRC03-12A10-7M
(15
●Dynamic measurement
ASH-A
Recommended
products for Strain Amplifier Compact Recording System Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination DPM-900 series EDX-10 series EDX-200A EDX-100A EDX-5000A
→ 3-5 → 3-49 → 3-55 → 3-63 → 3-68 2-124
2 AS-TG
-125 Small-sized Triaxial Acceleration Transducer
●Simultaneous measurement of acceleration
in X, Y and Z directions
●9.807 to 196.1 m/s2
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more
Environmental Characteristics
Safe Temperature -10 to 60°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 121 Ω ±1.7%
Output Resistance 121 Ω ±1.7%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
*TEDS-installed models are available. Inquiries are welcome.
Safe Overloads 1000% (With a stopper)
Frequency Response See table below.
Transverse Sensitivity 4% RO or less
Acceleration
Transducers
Outline
■Dimensions
General 26
10
Piezoelectric
4 M4 d=3.5
44
10 36
Gyro
26
36
44
2 φ4.5
thru-hole
Connector plug
PRC03-12A10-7M
20
C1
●Dynamic measurement
AS-TG
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10TB: 0.5 mV/V ±25%
Environmental Characteristics
Safe Temperature -15 to 65°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is connected to the case.)
*TEDS-installed models are available. Inquiries are welcome.
Mechanical Properties
Safe Overloads 300% (Each axis)
Frequency Response See table below.
Compact and lightweight design Transverse Sensitivity
Weight
2% RO or less
Approx. 95 g (Excluding cable)
and simultaneous measurement
of accelerations in X, Y, and Z
Rated Capacity
Models Frequency Response (At 23°C)
(Reference Value)
AS-10TB ±98.07 m/s2 (±10 G) DC to 350 Hz ±5%
directions AS-20TB ±196.1 m/s2 (±20 G) DC to 500 Hz ±5%
AS-50TB ±490.3 m/s2 (±50 G) DC to 1 kHz ±5%
Outline
■Dimensions
36 4 6
4
Piezoelectric
29
37
Gyro
(25)
C2
Connector plug
4.5
20
PRC03-12A10-7M
●Dynamic measurement
AS-TB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A
→ 3-5 → 3-9 → 3-49 → 3-63 2-126
2 ASHT-A
-127 Triaxial Acceleration Transducer
●Simultaneous measurement of acceleration
in X, Y and Z directions
●980.7 to 9807 m/s2
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
Environmental Characteristics
Compensated Temperature 5 to 40°C
Safe Temperature -15 to 65°C
Temperature Effect on Zero Within ±1% RO/°C
Temperature Effect on Output Within ±1% /°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 2 VAC or DC
Input Resistance 120 Ω ±8.3%
Output Resistance 120 Ω ±8.3%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by
5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
*TEDS-installed models are available. Inquiries are welcome.
Mechanical Properties
Safe Overloads 300%
directions ASHT-A-100
ASHT-A-200
±980.7 m/s2 (±100 G)
±1961 m/s2 (±200 G)
DC to 1.2 kHz ±5%
DC to 2.1 kHz ±5%
●Measurement from DC is possible ASHT-A-500 ±4903 m/s2 (±500 G) DC to 3 kHz ±10%
ASHT-A-1K ±9807 m/s2 (±1000 G) DC to 5 kHz ±10%
●3 acceleration transducers are within the same
case, enabling measurement in X, Y, and Z axes.
●Minimal mutual interference between each axis,
enabling high-accuracy measurement.
●Applicable to the analysis of acceleration in
complex vibration phenomena
●Compact & lightweight
Acceleration ■Dimensions
Transducers
38
Outline
16 30 4 3.5
φ6
General
φ3.5
22
30
Piezoelectric
4
(25)
Gyro
(4.6)
●Dynamic measurement
ASHT-A
Recommended
products for Strain Amplifier Compact Recording System Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination DPM-900 series EDX-10 series EDX-200A EDX-100A EDX-5000A
→ 3-5 → 3-49 → 3-55 → 3-63 → 3-68
2-127
ASW-A
Waterproof Acceleration Transducer
●Usable underwater or underground
●9.807 to 196.1 m/s2 2-128
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more
Environmental Characteristics
Safe Temperature -15 to 65°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 122 Ω ±1.6%
Output Resistance 122 Ω ±1.6%
Cable 4-conductor (0.08 mm ) chloroprene shielded cable,
2
General
18
(ASW-A)
18 (ASW-A)
Piezoelectric
6
8
φ34
M3 φ20 Gyro
M5 d=5 2 M3 thru-hole
φ20 2 3.4 drilled
φ6 counterbore d=4
2 3.4 drilled 11.6
2 3.4 drilled
φ6 counterbore d=6
60
4×M3 d=4
φ34
28
24
12
11.6
11.6 28
Sensitive Axes Connector plug
PRC03-12A10-7M DK-1C DK-1D
Weight: Approx. 5.3 g Weight: Approx. 13 g
Aluminum Aluminum
●Dynamic measurement
ASW-A
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A
→ 3-5 → 3-9 → 3-49 → 3-78 2-128
2 ASQ-D
-129 Servo Type Acceleration Transducer
●9.807 to 49.03 m/s2
●Measurement of minute vibrations
●IP67
Specifications
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±0.03% RO*1
Hysteresis Within ±0.05% RO*1
Rated Output ±5 V (10 V) ±5% *2
Environmental Characteristics
Safe Temperature -20 to 80°C
Compensated Temperature -10 to 60°C
Temperature Effect on Zero Within ±0.05% RO/°C
Temperature Effect on Output Within ±0.05%/°C
Electrical Characteristics
Power Supply ±11 to ±16 VDC, 40 mA or less (±12 V recommended)
Highly sensitive measurement of minute vibration Supplied from dedicated signal conditioner VAQ-700A,
if used.
Most suitable for vibration measurement of Cable N-41: (Optional Accessory) (For connecting ASQ-D and VAQ-700A)
6-conductor (0.2 mm2) vinyl shielded cable,
vehicles, structures and the ground 5.8 mm diameter by 50 m long
(Sensor side: 272FCW-12P)
●Acceleration measurement in a range of DC to (Measuring instrument side: PRC03-12A10-7M)
100 Hz is possible. (If desired, a model covering a N-42: (Optional Accessory)
range of DC to 300 Hz is available.) (Sensor side: 272FCW-12P)
●Compact & lightweight while ensuring high (Measuring instrument side: Bared at the tip)
accuracy and high output 1-G cancel cable: (Optional Accessory)
(WITCO OF JUPITER DENTSU CO., Ltd.)
Unlike conventional strain-gage acceleration 6-conductor (0.2 mm2) vinyl shielded cable,
5.8 mm diameter by 40 cm long
transducers, the acceleration transducers have a (Sensor side: 272FCW-12P)
servomechanism that ensures accurate, stable and (Measuring instrument side: 272MCW-12P)
reliable measurement of minute vibration with high
Mechanical Properties
sensitivity. A dedicated VAQ-700A signal conditioner
Frequency Response DC to 100 Hz (Sensitivity deviation ±10%)
is available as the mating instrument. (DC to 300 Hz available on request*1)
Measuring targets include vibration generated by Transverse Sensitivity 0.3% RO or less*2
running vehicles, earthquake or wind in structures and Degree of Protection IP67 (IEC 60529)
the ground as well as general low-frequency vibration. Weight Approx. 220 g (Excluding cable)
*1 Inspect by applying the current to a single coil.
*2 Inspect with ±1G (inclination).
Standard Accessories Hexagon socket head bolts (M4, length: 25) × 2
■Dimensions
Optional Accessories Connection cable N-41 (50 m), N-42 (5 m)
Acceleration 1-G cancel cable N-45 (40 cm)
dimensions with
counterbore 8 mm diameter
and 16 mm deep ASQ-D-1 ±9.807 m/s2 (±1 G)
(70)
22 22 50 m
Piezoelectric
(75)
5.8 mm diameter
(Option)
5m Bared at the tip
32.5
2-129 → 2-130
VAQ-700A
ASQ Dedicated Conditioner
●Simultaneous measurement of
acceleration, velocity and displacement 2-130
TRANSDUCERS
Signal conditioners allow acceleration, velocity and displacement to be
measured synchronously
●Easy-to-read LED indicator
●Single channel type. Multiple units are accommodated in a portable housing case for multi-channel measurement.
The 1-channel signal conditioner enables simultaneous measurement of acceleration, velocity by 1-time integration
and displacement by 2-time integration.
Specifications
Applicable Transducers ASQ-D-1 ASQ-D-2 ASQ-D-5
Number of Measuring Channels 1
Measuring Modes Simultaneous measurement and output of acceleration, velocity and displacement
Acceleration Measuring Range ±9.807 m/s2 (±1 G) ±19.61 m/s2 (±2 G) ±49.03 m/s2 (±5 G)
Range Select 0.01, 0.1, 1 G, OFF 0.02, 0.2, 2 G, OFF 0.05, 0.5, 5 G, OFF
Calibration Linked with selected range × 0.51
Accuracy ±0.5% FS to reading with both measuring range and calibration
Frequency Response DC to 300 Hz (±5%) in DC acceleration mode, 0.1 to 300 Hz (±5%) in AC acceleration mode
Velocity Measuring Range ±100 cm/s ±200 cm/s ±500 cm/s
Range Select 1, 10, 100 cm/s, OFF 2, 20, 200 cm/s, OFF 5, 50, 500 cm/s, OFF
Calibration Linked with selected range × 0.5 Acceleration
Accuracy ±1% FS to reading with both measuring range and calibration Transducers
Frequency Response 0.1 to 100 Hz (±5%)
Displacement Measuring Range ±100 mm ±200 mm ±500 mm Outline
Range Select 1, 10, 100 mm, OFF 2, 20, 200 mm, OFF 5, 50, 500 mm, OFF
Calibration Linked with selected range × 0.5
Accuracy ±1% FS to reading with both measuring range and calibration General
Frequency Response 0.1 to 60 Hz (±5%) (1 to 60 Hz, ±0.5% with a maximum sensitivity selected for the measuring range)
Output ±10 V (Load 5 kΩ or more)
Operating Temperature −10 to 50°C Piezoelectric
Power Supply 100 V AC or 12 VDC
Dimensions & Weight 49 W × 128.5 H × 262.5 D mm, approx.1.4 kg
Gyro
Standard Accessories AC power cable P-16 (With a conversion adapter CM-52), output cable U-58 (3 PC.), fuse, miniature screwdriver,
Instruction Manual
Optional Accessories Housing case YC-A (Page 3-21)
■Dimensions
49 2 φ3
8.5
111.5
122.5
128.5
262.5 13 48.6
8.5
2-130
2 ASPA-A/ASPB-A
-131 Piezoelectric Acceleration Transducer (Built-in Amplifier)
●2200 m/s2
TRANSDUCERS
Specifications
Rated Capacity ±2200 m/s2
Voltage Sensitivity 1.0 mV/m/s2 ±10%
Resonant Frequency Approx. 45 kHz
Frequency Response (±1 dB) 3 to 12000 Hz
Frequency Response (±3 dB) 1.5 to 16000 Hz
ASPA-A
Impact Resistant 10000 m/s2
Operating Temperature -30 to 110°C
Transverse Sensitivity 5% RO or less
Output Impedance 100 Ω or less
Weight ASPA-A-200: Approx. 2 g
ASPB-A-200: Approx. 3 g
Case Material Titanium
Mounting Screw Female screw (M3×0.5, depth 2)
ASPB-A
Power Supply 15 to 25 VDC, 0.5 to 5.0 mA
Cable Dedicated cable, length approx. 2 m
Sensor side: C29-104P
Measuring instrument side: Miniature connector
(Shield wire is connected to the case.)
Wide measurement range, capable Standard Accessories Miniature BNC conversion connector
of measuring slight through to high Optional Accessories Insulated stad
φ6.9
10.25
Outline
C29-103R
5.75
(Tajimi)
(4.2)
General C29-103R
(3.1)
(Tajimi)
9.2
11.5
Piezoelectric φ8.8
φ6
(2.3)
0.3
φ7.8
0.25 (4.5) 6.75
Gyro
11.5
Hex7
φ8.5
2.5
M3 0.5 depth 2
Detection direction arrow
on the cylindrical surface
M3 0.5 depth 2
ASPA-A ASPB-A
●Dynamic measurement
ASPA-A/
ASPB-A
Recommended
products for
Strain/Voltage/Acceleration
Measurement Card
+ Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A EDX-200A EDX-100A EDX-5000A
TRANSDUCERS
●360 to 4500 m/s2
ASPC-A Specifications
Rated Capacity See table below.
Voltage Sensitivity See table below.
Resonant Frequency Approx. 35 kHz
Frequency Response (±1 dB) 1 to 5000 Hz
Frequency Response (±3 dB) 1 to 8000 Hz
Impact Resistant 30000 m/s2
Operating Temperature ASPC-A-30/ASPC-A-300:
-50 to 110°C
(With operating power supply: 0.5 to 5 mA)
ASPC-A ASPD-A -50 to 70°C
(With operating power supply: 0.5 to 10 mA)
Measuring instrument side's operating
temperature: -20 to 60°C
ASPC-A-30-ID/ASPC-A-300-ID:
-40 to 85°C
(With operating power supply: 0.5 to 5 mA)
Wide measurement range, capable -40 to 70°C
of measuring slight through to high (With operating power supply: 0.5 to 10 mA)
accelerations.
Measuring instrument side's operating
temperature: -20 to 60°C
Transverse Sensitivity 5% RO or less
●High sensitivity, small size
Output Impedance 1000 Ω or less
●Capable of measurement of wide band, low to
Weight Approx. 11 g (Excluding cable)
high frequencies
Case Material Titanium
●High mechanical strength
Mounting Screw Female screw (M5×0.8, depth 3.5)
●Environmentally-resistant
Power Supply 21 to 24 VDC, 0.5 to 10 mA
Cable Dedicated cable, length approx. 3.3 m
Sensor side: DR-4S-1
Measuring instrument side: BNC connector (BNC163)
(Shield wire is connected to the case.) Acceleration
Voltage Sensitivity Transducers
Models Rated Capacity (±10%) TEDS Sensor ID TEDS (IEEE1451.4)
ASPC-A-30-ID ±360 m/s2 10 mV/m/s2 ✔ (ASPC-A-30 -ID/ ASPC-A-300 -ID only)
Outline
ASPC-A-30 ±400 m/s2 10 mV/m/s2 −
Optional Accessories Mount base
ASPD-A-45-ID ±450 m/s2 10 mV/m/s2 ✔
ASPD-A-45 ±450 m/s2 10 mV/m/s2 − *Acceleration (m/s2)
ASPC-A-300-ID ±3600 m/s2 1.0 mV/m/s2 ✔ = Output voltage from sensor (mV) ÷ Voltage sensitivity (mV/m/s2) General
ASPC-A-300 ±4000 m/s2 1.0 mV/m/s2 −
ASPD-A-450-ID ±4500 m/s2 1.0 mV/m/s2 ✔
ASPD-A-450 ±4500 m/s2 1.0 mV/m/s2 −
Piezoelectric
2-132
2-133
ASPD-A Specifications
Performance
Rated Capacity See table on the previous page.
Voltage Sensitivity See table on the previous page.
Environmental Characteristics
Mechanical Properties
Frequency Response (±5 dB) ASPD-A-45 (-ID):
(±5%) (X, Y): 2 to 7000 Hz
(Z): 2 to 10000 Hz
(±3 dB) (X, Y): 0.5 to 10000 Hz
Operating Temperature ASPD-A-45 (-ID): (Z): 0.5 to 18000 Hz
-50 to 110°C ASPD-A-450 (-ID):
(±5%) (X, Y): 2 to 10000 Hz
TRANSDUCERS
■Dimensions
Y
14.2
X
Acceleration
Transducers
Y
Outline
X
Y
(9.5) 14.2
Y
10
General
X
Z
X
14.2
Piezoelectric
(6.5) 10
Z
Gyro Z
X Z
10
DR-4S-4
X
CZ710
M5 0.8 depth 3.5 or more
Gasket M3 0.5 depth 2
ASPC-A ASPD-A
●Dynamic measurement
ASPC-A/
ASPD-A
Recommended
products for
Strain/Voltage/Acceleration
Measurement Card
+ Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A EDX-200A EDX-100A EDX-5000A
TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±20%
Peak-to-peak Sensitivity Error 4% RO or less
Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 60°C (Non-condensing)
Temperature Effect on Zero Within ± 0.5% RO / °C
Temperature Effect on Output Within ±1% /°C
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ± 7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ± 2.5 to ± 6 VDC
Single supply: 5 to 12 VDC
Current Consumption 20 mA or less (At 5 VDC)
Cable ① Sensor - relay part
7-conductor (0.04 mm2), vinyl shielded cable, 2.4 mm diameter
Small & durable accelerometers by 5 m long
② Relay part - connector
7-conductor (0.04 mm2), vinyl shielded cable, 2.4 mm
●High frequency response
diameter by 2 m long, terminated with a connector plug
●Safe overloads ±39227 m/s2 (±4000 G)
(PRC03-12A10-7M)
●No external power supply unit is necessary. *Shield wire is not connected to the case.
(When using the Strain/Voltage/Acceleration
Mechanical Properties
Measurement Card CVM-41A and A/D Converter
Safe Overloads ±39227 m/s2 (±4000 G)
Card AD-40AS) Transverse Sensitivity ±4% RO or less
Frequency Response DC to 2000 Hz (Sensitivity deviation: ±10%)
Weight Approx. 5 g (Excluding cable)
Sensor
General
11
Piezoelectric
6.3
(5 m)
Gyro
(2 m)
23
65
Connector plug
Relay part PRC03-12A10-7M
12
●Dynamic measurement
AMAS-A
+
Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A
→ 3-74 → 3-77 → 3-55 → 3-63 → 3-68 2-134
2 AMA-A
-135 Small-sized Triaxial Accelerometer
●Simultaneous measurement of acceleration
in X, Y and Z directions
TRANSDUCERS
AMA-A-2/5 Specifications
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO (100, 200: Within ±2% RO)
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less
Electrical Characteristics
Safe Excitation Dual supply: ± 7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ± 2.5 to ± 6 VDC
Single supply: 5 to 12 VDC
AMA-A-100/200 Current Consumption 10 mA or less (At 5 VDC)
(10-S1, 100, 200: 20 mA or less)
Cable See table below.
Mechanical Properties
Safe Overloads See table below.
Piezoelectric
+X
Gyro +Y
X axis
Y axis
Models Rated Capacity Safe Overloads Weight Cable
2-135
2
■Dimensions
AMA-A-2, 5 Sensor
14
C0.5 12.5
-136
10
7
2×φ1.8
TRANSDUCERS
5.8
Relay cable (Option)
・TE-55
Cable length: Approx. 30 cm Relay part
Relay part: Dedicated connector
Measuring instrument side: PRC03-12A10-7M (50)
30
(21)
・TE-56
Cable length: Approx. 30 cm
Relay part: Dedicated connector
Measuring instrument side: PRC05-P8M
(9)
Relay part
AMA-A-10-S1 15
(7)
Sensor (5 m)
11
(13.5)
2 φ1.8
23
AMA-A-10
SER No.
Acceleration
12 Transducers
Outline
AMA-A-100/200 19.3
(7)
(5 m)
Sensor
General
11
(13.5)
2 φ1.8
Piezoelectric
11
65
(15 cm)
23
AMA-A-
SER No.
12
●Dynamic measurement
AMA-A
+
Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A
→ 3-74 → 3-77 → 3-55 → 3-63 → 3-68 2-136
2 GSAT-A-900
-137 Three Axis Angular Rate Gyro
●±15.71 rad/s
Specifications
TRANSDUCERS
Performance
Rated Capacity ±15.71 rad/s (±900 deg/s)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2.0 V
Environmental Characteristics
Safe Temperature −10°C to 60°C
Compensated Temperature 5°C to 40°C
Temperature Effect on Zero Within ±1.0% RO/°C
AMA-A-2/5 Electrical Characteristics
Safe Excitation Dual supply: ±6.0 VDC
Single supply: 12 VDC
Recommended Excitation Dual supply: ±2.5 to ±5.0 VDC
With single supply, see to the instruction manual.
No-load Output Within ±10% RO
Cable Sensor side: 9-conductor (0.04 mm2) vinyl shielded cable,
GSAT-A 2.7 mm diameter by approx. 7 m long
Relay: 4-conductor (0.05 mm2) vinyl shielded cables,
2.6 mm diameter by approx. 1 m long, terminated with
connector plugs PRC03-12A10-7M
+X
■Dimensions
Acceleration
Transducers Sensor
20 2 φ1.8 9-conductor (0.04 mm2) vinyl shielded cable,
Outline 2.7 mm diameter by approx. 7 m long
18.5
10
Centroid positions
3.3
General
7
3.3
8.7
10
Piezoelectric
8
5.4
Relay cable
Centroid of Centroid of
Gyro X-axis element Y-axis element
(12)
(100)
4-conductor (0.05 mm2) vinyl shielded cable, *1
PRC03-12A10-7M
6
Z-axis element
●Dynamic measurement
GSAT-A
+
Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A
TRANSDUCERS
Acceleration
Transducers
Outline
General
Piezoelectric
Gyro
2-138
5 ASD-B
-21 Acceleration Transducer for Crash Test
●For crash tests ●9807 m/s2, 19613 m/s2
Specifications
AUTOMOTIVE TEST EQUIPMENT
Performance
Rated Capacity See table below.
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1.2 mV/V or more
Peak-to-peak Sensitivity Error 1% RO or less
Environmental Characteristics
Safe Temperature –20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±0.5% RO/°C
Temperature Effect on Output Within ±0.1%/°C
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
Measures acceleration of Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
crash-test cars. (Shield wire is not connected to the case.)
7.6 0.1
10 (4.5) 10 (4.5)
12.5 12.5
4.7
4.7
1
Type V Type H
2.6 6.1 2.6 6.1
4.6
4.6
Connector plug
R05-PB5M
Center of mass Center of mass
ASD-B-1KV/2KV ASD-B-1KH/2KH
ASD-B
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
5-21 → 5-38 → 5-46 → 5-47
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
(Horizontal) Temperature Effect on Zero Within ±0.5% RO/°C
Temperature Effect on Output Within ±0.1%/°C
Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
7.6
10
10
5 5
10 (4.5) 10 (4.5)
12.5 12.5
4.7
4.7
2
2.6
2.6
Type V Type H
Sensitive Axis Sensitive Axis
6.1 6.1
4.6
Connector plug
R05-PB5M
ASDH-A-1KV/2KV ASDH-A-1KH/2KH
ASDH-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-22
It requires change of the conversion cable or plug.
5 ASE-A
-23 Damped Acceleration Transducer for Crash Test
●For crash tests ●980.7 m/s2 to 9807 m/s2
Specifications
AUTOMOTIVE TEST EQUIPMENT
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output See table below.
Peak-to-peak Sensitivity Error 1% RO or less
Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 300 to 1000 Ω
Output Resistance 300 to 1000 Ω
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)
Mechanical Properties
Measures acceleration of car bodies, Frequency Response See table below.
Crash test
measuring
system Models Rated Capacity Rated Output Frequency Response (23°C) Safe Overloads
DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-100 ±980.7 m/s2 (±100 G) 0.5 mV/V or more 500%
Crash test 1 kHz to 2 kHz (Sensitivity deviation±10%)
software DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-500 ±4903 m/s2 (±500 G) 1 mV/V or more 400%
1 kHz to 4 kHz (Sensitivity deviation±10%)
DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-1K ±9807 m/s2 (±1000 G) 2 mV/V or more 200%
1 kHz to 4 kHz (Sensitivity deviation±10%)
ASE-A
Recommended Data Acquisition System Small-sized Data Logger Small-sized Data Logger
products for for Crash Test for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-503A DIS-618A/632A DIS-5210A
5-23 → 5-38 → 5-46 → 5-46 → 5-47
Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% / °C
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 300 to 1000 Ω
Output Resistance 300 to 1000 Ω
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)
Mechanical Properties
Measures acceleration of car bodies Safe Overloads See table below.
■Dimensions
Cable is exchangeable
when damaged.
To Ensure Safe Usage
10 (26)
(8) ●When conducting the Pedestrian Head Protection
Performance Test, ground the aluminum skull
8
(9.5)
(4.3)
Connector plug
2.3
R05-PB5M
Mounting surface
Center of mass
ASER-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-24
It requires change of the conversion cable or plug.
5 ASDE-A
-25 Damped Acceleration Transducer for Crash Test
Specifications
AUTOMOTIVE TEST EQUIPMENT
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output See table below.
Peak-to-peak Sensitivity Error 1% RO or less
Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
The oil damped design is least Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
affected by impact acceleration- (Shield wire is not connected to the case.)
Crash test
software ■Dimensions
2 1.8
7.6 0.1
10
11.5 (5)
13.5
XXXXXXXXX
4.9
Sensitive Axis
1
2.6 4.5
Connector plug
R05-PB5M
4.6
Center of mass
ASDE-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
5-25 → 5-38 → 5-46 → 5-47
Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
The oil damped design is least affected by Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
impact acceleration-initiated resonance. (Shield wire is not connected to the case.)
Mechanical Properties
●For crash tests
Safe Overloads 200%
Vehicle, components acceleration measurement Frequency Response DC to 1 kHz at 23°C (Sensitivity deviation ±3%)
●Damped type 1 to 4 kHz (Sensitivity deviation ±10%)
Because this is an oil-damped type, there is Transverse Sensitivity 2% RO or less
little adverse impact from resonant output in Weight Approx. 1.2 g (Excluding cable)
Automotive Test
pedestrian head impact protection function Optional Accessories Equipment
Conversion cable TT-18
tests and vehicle crash safety tests. Automotive
●Compact, lightweight and flangeless performance
test
Mounting in limited space is possible.
●Cable is exchangeable when damaged.
Crash test
Crash test
measuring
system
■Dimensions
Crash test
R05-PB5M software
Enlarged View A
13
5
(9)
5.4
(22)
2.7
Connector plug
Sensitive Axis R05-PB5M
4.4
(1.2)
(3.6)
Center of mass
A
ASDR-A-1K
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-26
It requires change of the conversion cable or plug.
5 ASM-200BA
-27 Semiconductor Acceleration Transducer for Crash Test
●1961 m/s2
Specifications
AUTOMOTIVE TEST EQUIPMENT
Performance
Rated Capacity ±1961 m/s2 (±200 G)
Nonlinearity Within ±1% RO (Within ±0.5% RO optional)
Hysteresis Within ±1% RO
Rated Output 1.3 mV/V or more
Peak-to-peak Sensitivity Error 1.5% RO or less
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±2% RO/°C
(Within ±1% RO/°C optional)
Temperature Effect on Output -0.25 to 0%/°C
Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Measures acceleration of car bodies Output Resistance 120 Ω ±20%
and dummies. Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter
by 7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)
●Compact and lightweight design (approx. 1.2 g)
causes minimal influence to the vibration mode Mechanical Properties
of a measuring object. Safe Overloads 500%
●High safe overload rating 500% Frequency Response DC to 3.5 kHz at 23°C (Sensitivity deviation ±5%)
●No damping oil resulting in no temperature Resonance Frequency 21 kHz ±10%
effects on frequency response and phase Transverse Sensitivity 3% RO (1% RO optional) or less
Automotive Test Weight Approx. 1.2 g (Excluding cable)
Equipment characteristics.
Automotive ●Undamped design ensures minimal phase shift. Optional Accessories Conversion cable TT-18
performance
test
The ASM-200BA acceleration transducer adopts
semiconductor strain gages for the sensing element. Its To Ensure Safe Usage
Crash test
compact and lightweight design less affects to vibration ●Excitation voltage should be 2 VDC.
mode of measuring objects. Thus, it is applicable to ●Use screws to mount the acceleration
Crash test various acceleration or vibration measurement. transducer. Removing the transducer mounted
measuring
system with an adhesive may give it impact, thereby
causing damage.
Crash test
software
●Bore screw holes for M1.6 or No. 0-80UNF
in the measuring object. Tightening torque
should be 0.08 to 0.1 N・m (0.8 to 1 kgf・cm).
●When mounting with screws, slightly apply
silicone oil or grease to the contact surface.
Resultant closer contact will ensure better
fixing condition.
●This transducer comes with a connector, whose
initial balance has been achieved. Therefore,
if the transducer is to be used after removal
of the connector, contact us for necessary
information.
■Dimensions
4.6 (2.5)
15
7
Metal Sleeve
(Outer diameter 2.1)
4.6
10
7.6
Connector plug
R05-PB5M
1
4.5 2 φ1.8
Sensitive Axes
Center of mass
ASM-200BA
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
5-27 → 5-38 → 5-47
Transducer
output polarity (+) (+) (+)
■Dimensions
25
14
2.1
2 M1.6
Nut
12
9
3.6
Rubber cap
5
Joined surface
5.4
Connector plug
R05-PB5M
2.6
0.9
ASM-
1KBCV/BCH M3
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
→ 5-38 → 5-47 5-28
It requires change of the conversion cable or plug.
5 ASM-A-ID
-29 Semiconductor Acceleration Transducer for Crash Test
●For crash tests ●19613 m/s2
AUTOMOTIVE TEST EQUIPMENT
Specifications
Performance
Rated Capacity ±19613 m/s2 (±2000 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
ASM-A-2KV-ID Rated Output 6 mV/V or more
Peak-to-peak Sensitivity Error 1.5% RO or less
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±3% RO/°C
Temperature Effect on Output -1 to 0% / °C
ASM-A-2KH-ID
Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Output Resistance 120 Ω ±20%
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 3.2 mm diameter by 8 m
long, terminated with a connector plug 3RT01-PE7M (TEDS installed)
(Shield wire is not connected to the case.)
Transducer
output polarity (+) (+) (+)
■Dimensions
3RT01-PE7M
(16)
25
14
5.4 0.3
12
9
Connector plug
2 x M1.6 Cross-recessed
0.9
3RT01-PE7M
Sensitive Axes Sensitive Axes round head machine screw 3.6
(ASM-A-2KH-ID) (ASM-A-2KV-ID) 5
ASM-A-ID
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
5-29 → 5-38 → 5-47
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±2% RO/°C
Temperature Effect on Output -0.25 to 0%/°C
Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Output Resistance 120 Ω ±20%
Cable 4-conductor (0.035 mm2) shielded cable, 1.7 mm diameter by
7 m long, terminated with connector plugs at both ends
(Sensor side: MR01-P4F, Measuring instrument side: R05-PB5M)
(Shield wire is not connected to the case.)
For crash tests Mechanical Properties
12.5 (13.1)
7.7 6
4 2.8
2 0.5
12.4
16
7.4
Connector plug
R05-PB5M
φ6.5
ASM-1KCBV
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
→ 5-38 → 5-47 5-30
It requires change of the conversion cable or plug.
You can count on Kyowa.
Feel free to contact us,
if there is something you would like to know or
do not understand about Kyowa products.
Applications of
Applications ofthe
theenergy industry
automotive
+
Y
-
Z X
- +