2-117 Acceleration Transducers
■Acceleration Transducers
Kyowa's strain-gage acceleration transducers convert
TRANSDUCERS

the acceleration of running vehicle or the vibration of


car body or machinery into minute voltage to enable
accurate measurement of acceleration or vibration with
various measuring instruments. Each model is compact
and lightweight, and ensures superior static and dynamic
characteristics. Various rated capacity models cover a
wide scope of applications. In addition, triaxial models are
available for simultaneous detection of accelerations in three
directions: X, Y and Z.

Features

●Compact and lightweight design results in minimal


effects on the vibration mode of the measuring Strain gage

objects to which the transducer is mounted.


●Wide frequency response range enables faithful
detection of impact-initiated acceleration.
●Fatigue life is 10 million times or more.

■Principle of Acceleration Transducers ●There are 2 marks which indicates the sensitivity axis of
acceleration.
With the basic configuration shown below, acceleration (1) When the arrow which indicates the sensitivity axis is "+←
initiates inertia force to the weight and deforms the leaf → -";In case a acceleration transducers is set as ”+” points the
spring. The strain gage adhered to the leaf spring detects earth's center (Direction for Acceleration of Gravity),+1 G is
the displacement of the leaf spring as a strain quantity output when any load is not added. As the output is based on
proportional to the acceleration. The strain-gage signal Acceleration of Gravity, the relationship between input condition
is amplified to enable acceleration measurement. An and output of acceleration is shown on the following table.
advantageous feature of this configuration is to enable the
Acceleration Impact Rotation It agrees with a
transducer to respond to static acceleration at DC. motion of a plumb
Center of bob and outputs
rotation
1 G at the time
Acceleration of stillness.
Weight Strain gage Gravitational
conditions
Sensitivity direction

acceleration is
to be basic
Acceleration
Transducers
Leaf spring Polarity of
output
Outline
(2) When the arrow which indicates the sensitivity axis is " ↑ " ;
Arrows on the case “ ”
General Fig. 1 Basic Configuration of strain-gage Acceleration Transducer Acceleration Impact Rotation
The arrow on
Center of the the case is
Acceleration rotation
in accordance
Piezoelectric conditions with the
direction of
■Installation and Removal acceleration.
Polarities of output
Gyro
Install the acceleration transducer aligning the sensitive axis
("+ ← →-" marked on the transducer) with the acceleration
Note: Please check instruction Acceleration transducers are
measuring direction.
installed to objects by adhesives like CC-33A, bolts, or mount
bases. To measure correctly, mount acceleration transducers
following instruction manual. When removing acceleration
transducers, take sufficiently care to avoid excessive impact or
force resulting in damaging transducers.
Measurement of
acceleration
Output Ratio (%) Output Ratio (%)

Screw/Bolt
Acceleration

in horizontal direction 120


110
100
90
80
AS-50HB 10 2 Frequency (Hz) 10 3

Measurement of acceleration
Bonded
in vertical direction
Acceleration

120
(CC-33A)
(Measuring range in the up direction 110
is narrower by 9.807 m/s2 (1 G).) 100
90
Fig. 2 Installing or Removing Acceleration Transducers 80
AS-50HB 10 2 Frequency (Hz) 10 3

Fig. 3 Example of Frequency Response

2-117
Acceleration Transducers Measurement Examples
2-118

TRANSDUCERS
●Vibration tests of goods during truck transportation

Small-sized Triaxial Accelerometer


AMA-A

Universal Recorder
EDX-200A

Acceleration
Transducers

Outline
■Temperature Effect on Frequency Response ■Overload Considerations
To ensure flat frequency response characteristics, some Generally, the magnitude of acceleration is difficult to be
models of acceleration transducers have oil sealed inside. The grasped by human perception. If the transducer is dropped General
viscosity of the oil is adjusted to make the frequency response on the floor, it may easily sense acceleration exceeding
flat at 23°C. Changes in viscosity due to temperature changes 9807 m/s2 (1000 G) depending on the material of the
affect the frequency response and phase characteristics. floor. If a small-capacity acceleration transducer receives Piezoelectric
Though a silicone oil which the viscosity hardly changes an acceleration 10 times larger than the rated capacity, the
is adopted, the frequency response characteristics of the initial voltage unbalance changes outstandingly, thereby
transducer are affected by temperatures as shown in the making the transducer unusable due to disconnection of the
Gyro
figure below. Thus, for accurate measurement in a frequency gage, etc. Thus, the acceleration transducer must be handled
zone exceeding one-tenth the stated frequency response carefully
range, the temperature of the transducer should be kept
around 23°C. We assume 1 G = 9.807 m/s2 in this catalog.

33°C
+10%
Output Sensitivity (%)

23°C
100

−10% 13°C

−2°C

AS-50HB

100 1000
Frequency (Hz)

Example of Temperature Effect on Frequency Response

2-118
2-119
●Vibration tests on railway vehicle and truck
TRANSDUCERS

Small-sized Triaxial
Accelerometer
AMA-A
Universal Recorder
EDX-200A

●Drop impact tests of fuel cell container and lithium-ion battery

Small-sized High
Frequency Response
Acceleration Transducer
ASH-A
Acceleration
Transducers
Memory Recorder/Analyzer
Outline EDX-5000A

General
●Vibration tests on various structures such as piers

Piezoelectric

Gyro

Small-sized Triaxial Acceleration Transducer


AS-TG

Memory Recorder/Analyzer
EDX-5000A

2-119
Acceleration Transducer Selection Chart 2-120

Rated Capacity (±m/s2)


General Purpose

TRANSDUCERS
9.807 19.61 49.03 98.07 196.1 490.3 980.7 1961 4903 9807 Pages
Models (1 G) (2 G) (5 G) (10 G) (20 G) (50 G) (100 G) (200 G) (500 G) (1000 G)
Small-Large Capacity
Small-sized
Triaxial Yes Yes Yes Yes Yes 2-135
AMA-A
Large Capacity
Small-sized Yes Yes 2-134
AMAS-A
Medium Capacity
Small-sized Yes Yes Yes 2-122
AS-B
Small-
Medium Capacity
Yes Yes Yes Yes Yes 2-121
Small-sized AS-GA
Small Capacity Small-
Medium Capacity Yes Yes Yes Yes Yes 2-121
AS-GB
Large Capacity
Small-sized Yes Yes Yes Yes 2-124
ASH-A
High Medium Capacity
Frequency Yes Yes Yes 2-123
Response AS-HB
Large Capacity
Triaxial Yes Yes Yes Yes 2-127
ASHT-A
Small-sized,
Servo Type Output ±5 V FS Yes Yes Yes 2-129
ASQ-D
Medium Capacity
Triaxial Yes Yes Yes 2-126
AS-TB
Small-
Small-sized Medium Capacity
Triaxial Yes Yes Yes Yes Yes 2-125
AS-TG
Small-
Water Proof Medium Capacity Yes Yes Yes Yes Yes 2-128
ASW-A

Rated Capacity (±m/s2)


Piezoelectric Pages
Models 360 400 450 2200 3600 4000 4500
(36.7 G) (40.8 G) (45.9 G) (224.3 G) (367.1 G) (407.9 G) (458.9 G)
Large Capacity Acceleration
Piezoelectric
type
Yes 2-131 Transducers
ASPA-A
Large Capacity Outline
Piezoelectric
type
Yes 2-131
ASPB-A
Triaxial
Triaxial Yes Yes Yes Yes 2-132 General
ASPC-A(-ID)
Triaxial
Triaxial Yes Yes 2-132
Piezoelectric
ASPD-A(-ID)

Gyro Rated Capacity (±rad/s)


Pages Gyro
Model 15.71 (900 deg/s)

Three Axis Angular Rate Gyro


Yes 2-137
GSAT-A-900

Acceleration Transducers for Crash Test


Models Pages Models Pages Models Pages

ASD-B ASER-A ASM-200BA


5-27
5-21 5-24
ASM-1KBCV/BCH M3
ASDH-A ASDE-A 5-28

5-22 5-25
ASM-A-ID
5-29
ASE-A ASDR-A-1K
ASM-1KCBV
5-23 5-26 5-30

2-120
2 AS-GA/GB
-121 Small-sized Small-capacity Acceleration Transducer
●9.807 to 196.1 m/s2

Specifications
TRANSDUCERS

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more

Environmental Characteristics
Safe Temperature -15 to 65°C

AS-GA Electrical Characteristics


Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
AS-GB
Input Resistance 121 Ω ±1.7%
*AS-GB is available in TEDS-installed version. Inquiries are welcome. Output Resistance 121 Ω ±1.7%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by
5 m long
AS-GA Dedicated cable CB-AS-GA
Compact & lightweight Sensor side: Dedicated connector (removable)

Easy to use

Measuring instrument side: PRC03-12A10-7M
(Shield wire is not connected to the case.)
Suitable for measurement of

AS-GB Terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)
vibration of model structures and Mechanical Properties
in the field of human engineering. Safe Overloads 300%
Frequency Response See table below.
Using a strain gage as the sensing element, AS-GA and Transverse Sensitivity 4% RO or less
AS-GB series acceleration transducers are designed Weight Approx. 15 g (AS-GA) (Excluding cable)
to measure small levels of acceleration. The compact Approx. 25 g (AS-GB) (Excluding cable)
& lightweight design makes them widely used for
Rated Capacity
measurement of vibration in small structures or scale Models
(Reference Value)
Frequency Response (At 23°C)
models as well as in the field of human engineering. AS-1GA, GB ±9.807 m/s2 (±1 G) DC to 40 Hz ±5%
AS-GA series comes with hermetic terminal and AS-GB AS-2GA, GB ±19.61 m/s2 (±2 G) DC to 60 Hz ±5%
series are integrated with cable. AS-5GA, GB ±49.03 m/s2 (±5 G) DC to 100 Hz ±5%
AS-10GA, GB ±98.07 m/s2 (±10 G) DC to 150 Hz ±5%

■Dimensions
AS-20GA, GB ±196.1 m/s2 (±20 G) DC to 250 Hz ±5%
(Note) To install AS-GB, use CC-33A adhesive or optional mount base
(See figures below).
Sensitive

(Note) The acceleration transducer is subject to a constant acceleration


14

Axis

in the direction of gravity, therefore measurement is restricted,


Acceleration taking into account this vertical movement (9.807 m/s2).
Transducers Dedicated connector mounting screw For the AS-1GA/1GB, if sensitivity is set in line with the direction
13.8 of gravity, then the rated capacity will be exceeded. As long as the
Outline safe overload rating is not exceeded, there will be no damage, but
characteristics will be outside the guaranteed range.
■Mount Base
18
15

(6) 3
(6) 3

General

4 M2 d=3 (AS-GA, GB)


10 10
Mounting screw hole (AS-GA, GB)
13.8
Piezoelectric AS-GA 14
5
Sensitive Axis

2.5
5

32
14

Gyro 25
4.5
2.5

16 10
10.4
(25) 13.8
3
25
20

2 3.6
1
(6) 3

(6) 3

drilled hole

M4 2 2.2drilled hole
10 4 M2 d=3 10 φ4.2 counterbore
Mounting screw hole 2 2.2 drilled hole d=2.5
13.8
φ4.2 counterbore, d=2.5 2 M3 through hole
AS-GB 14 Connector plug
PRC03-12A10-7M DK-1A DK-1B
Weight: Approx. 2.5 g, Weight: Approx. 10 g,
aluminum aluminum

●Dynamic measurement

AS-GA/GB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A

2-121 → 3-5 → 3-9 → 3-49 → 3-78


AS-B
Small-sized Acceleration Transducer
●Compact & lightweight ●98.07 to 490.3 m/s2 2-122
Specifications

TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10B: 0.5 mV/V ±25%

Environmental Characteristics
Safe Temperature -10 to 60°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is connected to the case.)

*TEDS-installed models are available. Inquiries are welcome. Mechanical Properties


Safe Overloads 300%
Frequency Response See table below.
Transverse Sensitivity 2% RO or less
Compact & lightweight Weight Approx. 13 g (Excluding cable)

Barely disturbs the vibration mode Rated Capacity


of the object under measurement. Models
AS-10B
(Reference Value)
±98.07 m/s2 (±10 G)
Frequency Response (At 23°C)

DC to 350 Hz ±5%
The compact and lightweight design barely disturbs AS-20B ±196.1 m/s2 (±20 G) DC to 500 Hz ±5%
AS-50B ±490.3 m/s2 (±50 G) DC to 1 kHz ±5%
the vibration mode of the object under measurement.
Easy installation is ensured using CC-33A adhesive.

Acceleration
Transducers

Outline

■Dimensions General

Piezoelectric
Sensitive Axis

16.5

Gyro

φ14
(0.5)
16

Connector plug
16 (25) PRC03-12A10-7M

●Dynamic measurement

AS-B
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A
→ 3-5 → 3-9 → 3-49 → 3-78 2-122
2 AS-HB
-123 Small-sized High Frequency Response Acceleration Transducer
●High frequency response ●98.07 to 490.3 m/s2

Specifications
TRANSDUCERS

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10HB: 0.5 mV/V ±25%

Environmental Characteristics
Safe Temperature -15 to 65°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter
by 5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is connected to the case.)

Mechanical Properties
*TEDS-installed models are available. Inquiries are welcome. Safe Overloads 300%
Frequency Response See table below.
Transverse Sensitivity 2% RO or less
Weight Approx. 13 g (Excluding cable)
Highly accurate and reliable
Wide frequency response range Models
Rated Capacity
(Reference Value)
Frequency Response (At 23°C)

AS-10HB ±98.07 m/s2 (±10 G) DC to 500 Hz ±5%


AS-20HB ±196.1 m/s2 (±20 G) DC to 650 Hz ±5%
AS-50HB ±490.3 m/s2 (±50 G) DC to 1.5 kHz ±5%
AS-HB series acceleration transducers provide twice
wider frequency response range than AS-B series
at maximum. Therefore, AS-HB series ensure more
accurate acceleration measurements. It is easy to install
AS-HB by using the adhesive CC-33A.

Acceleration
Transducers

Outline

General ■Dimensions

Piezoelectric
Sensitive Axis

16.5

Gyro

(φ14)
(0.5)
16

16 (25) Connector plug


PRC03-12A10-7M

●Dynamic measurement

AS-HB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A

2-123 → 3-5 → 3-9 → 3-49 → 3-63


ASH-A
Small-sized High Frequency Response Acceleration Transducer
●980.7 to 9807 m/s2 2-124
Specifications

TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%

Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO/°C
Temperature Effect on Output Within ±1%/°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 120 Ω ±8.3%
Output Resistance 120 Ω ±8.3%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
*TEDS-installed models are available. Inquiries are welcome.
PRC03-12A10-7M
(Shield wire is not connected to the case.)

Mechanical Properties

Compact and lightweight design Safe Overloads


Frequency Response
300%
See table below.
resulting in slight effects on Transverse Sensitivity
Weight
2% RO or less
Approx. 6.5 g (Excluding cable)
vibration mode
Rated Capacity
Models Frequency Response (At 23°C)
(Reference Value)
Compact and lightweight design of ASH-A series ASH-A-100 ±980.7 m/s2 (±100 G) DC to 2 kHz ±5%
acceleration transducers do not disturb vibration mode ASH-A-200 ±1961 m/s2 (±200 G) DC to 3.5 kHz ±5%
of objects by installing these transducers. In addition, ASH-A-500 ±4903 m/s2 (±500 G) DC to 5 kHz ±10%
ASH-A-1K ±9807 m/s2 (±1000 G) DC to 7 kHz ±10%
it is easy to install ASH-A acceleration transducers by
adhesives like CC-33A.

Acceleration
Transducers

Outline

■Dimensions General
Sensitive Axis

Piezoelectric
15.5
(0.5)

Gyro

φ12
(5.7)

14 (25)
Flat-to-flat

Connector plug
.2)

PRC03-12A10-7M
(15

●Dynamic measurement

ASH-A
Recommended
products for Strain Amplifier Compact Recording System Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination DPM-900 series EDX-10 series EDX-200A EDX-100A EDX-5000A
→ 3-5 → 3-49 → 3-55 → 3-63 → 3-68 2-124
2 AS-TG
-125 Small-sized Triaxial Acceleration Transducer
●Simultaneous measurement of acceleration
 in X, Y and Z directions
●9.807 to 196.1 m/s2

Specifications
TRANSDUCERS

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more

Environmental Characteristics
Safe Temperature -10 to 60°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 121 Ω ±1.7%
Output Resistance 121 Ω ±1.7%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is not connected to the case.)

Mechanical Properties
*TEDS-installed models are available. Inquiries are welcome.
Safe Overloads 1000% (With a stopper)
Frequency Response See table below.
Transverse Sensitivity 4% RO or less

Able to withstand against Weight Approx. 110 g (Excluding cable)

10 times larger overload than Models


Rated Capacity
(Reference Value) Frequency Response (At 23°C)

rated capacity by the built-in AS- 1TG


AS- 2TG
±9.807 m/s2 (±1 G)
±19.61 m/s2 (±2 G)
DC to 40 Hz
DC to 60 Hz
±5%
±5%
overload stopper AS- 5TG
AS-10TG
±49.03 m/s2 (±5 G)
±98.07 m/s2 (±10 G)
DC to 100 Hz
DC to 150 Hz
±5%
±5%
AS-20TG ±196.1 m/s2 (±20 G) DC to 250 Hz ±5%
AS-TG series acceleration transducers have 3
Notes: The acceleration transducer is subject to a constant acceleration in
incorporated miniature acceleration transducers to the direction of gravity, therefore measurement is restricted, taking
measure simultaneously 3 axial accelerations (X, Y, and into account this vertical movement (9.807 m/s2).
Z). Not only are interferences of AS-TG series among In terms of AS-1TG, detected value exceeds rated capacity in
positive side toward gravity direction. As long as the safe overload
each axes little, but also AS-TG series withstand against rating is not exceeded, there will be no damage, but characteristics
10 times larger overload than rated capacity. will be outside the guaranteed range.

Acceleration
Transducers

Outline
■Dimensions

General 26
10

Piezoelectric
4 M4 d=3.5
44
10 36
Gyro
26

36
44

2 φ4.5
thru-hole

Connector plug
PRC03-12A10-7M
20

C1

●Dynamic measurement

AS-TG
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A

2-125 → 3-5 → 3-9 → 3-49 → 3-63


AS-TB
Triaxial Acceleration Transducer
●Simultaneous measurement of acceleration
 in X, Y and Z directions
●98.07 to 490.3 m/s2 2-126
Specifications

TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%
10TB: 0.5 mV/V ±25%

Environmental Characteristics
Safe Temperature -15 to 65°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 120 Ω ±5%
Output Resistance 120 Ω ±5%
Cable 4-conductor (0.08 mm2) vinyl shielded cable,
3.2 mm diameter by 5 m long, terminated with a connector plug
PRC03-12A10-7M
(Shield wire is connected to the case.)
*TEDS-installed models are available. Inquiries are welcome.
Mechanical Properties
Safe Overloads 300% (Each axis)
Frequency Response See table below.
Compact and lightweight design Transverse Sensitivity
Weight
2% RO or less
Approx. 95 g (Excluding cable)
and simultaneous measurement
of accelerations in X, Y, and Z
Rated Capacity
Models Frequency Response (At 23°C)
(Reference Value)
AS-10TB ±98.07 m/s2 (±10 G) DC to 350 Hz ±5%
directions AS-20TB ±196.1 m/s2 (±20 G) DC to 500 Hz ±5%
AS-50TB ±490.3 m/s2 (±50 G) DC to 1 kHz ±5%

AS-TB series acceleration transducers have 3


incorporated acceleration transducers to measure
simultaneously 3 axial accelerations (X, Y and Z).
Because of little interference among each axes,
these series acceleration transducers enable accurate
measurement and be applied to acceleration analysis
of complex vibration phenomena. Acceleration
Transducers

Outline
■Dimensions

44 2 φ3.5 φ6 counterbore General

36 4 6
4

Piezoelectric
29

37

Gyro
(25)

C2

Connector plug
4.5

20

PRC03-12A10-7M

●Dynamic measurement

AS-TB
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Universal Recorder
combination DPM-900 series CDV-900A EDX-10 series EDX-100A
→ 3-5 → 3-9 → 3-49 → 3-63 2-126
2 ASHT-A
-127 Triaxial Acceleration Transducer
●Simultaneous measurement of acceleration
 in X, Y and Z directions
●980.7 to 9807 m/s2

Specifications
TRANSDUCERS

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V ±20%

Environmental Characteristics
Compensated Temperature 5 to 40°C
Safe Temperature -15 to 65°C
Temperature Effect on Zero Within ±1% RO/°C
Temperature Effect on Output Within ±1% /°C

Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 2 VAC or DC
Input Resistance 120 Ω ±8.3%
Output Resistance 120 Ω ±8.3%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by
5 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
*TEDS-installed models are available. Inquiries are welcome.
Mechanical Properties
Safe Overloads 300%

Compact and lightweight design Frequency Response


Transverse Sensitivity
See table below.
2% RO or less
and simultaneous measurement Weight Approx. 45 g (Excluding cable)

of accelerations in X, Y, and Z Models


Rated Capacity
(Reference Value)
Frequency Response (At 23°C)

directions ASHT-A-100
ASHT-A-200
±980.7 m/s2 (±100 G)
±1961 m/s2 (±200 G)
DC to 1.2 kHz ±5%
DC to 2.1 kHz ±5%
●Measurement from DC is possible ASHT-A-500 ±4903 m/s2 (±500 G) DC to 3 kHz ±10%
ASHT-A-1K ±9807 m/s2 (±1000 G) DC to 5 kHz ±10%
●3 acceleration transducers are within the same
case, enabling measurement in X, Y, and Z axes.
●Minimal mutual interference between each axis,
enabling high-accuracy measurement.
●Applicable to the analysis of acceleration in
complex vibration phenomena
●Compact & lightweight

Acceleration ■Dimensions
Transducers
38
Outline
16 30 4 3.5
φ6

General
φ3.5
22

30

Piezoelectric
4

(25)

Gyro
(4.6)

(4.6) Connector plug


PRC03-12A10-7M
(16)
(28.5)

●Dynamic measurement

ASHT-A
Recommended
products for Strain Amplifier Compact Recording System Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination DPM-900 series EDX-10 series EDX-200A EDX-100A EDX-5000A
→ 3-5 → 3-49 → 3-55 → 3-63 → 3-68
2-127
ASW-A
Waterproof Acceleration Transducer
●Usable underwater or underground
●9.807 to 196.1 m/s2 2-128
Specifications

TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.5 mV/V or more

Environmental Characteristics
Safe Temperature -15 to 65°C
Electrical Characteristics
Safe Excitation 6 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 122 Ω ±1.6%
Output Resistance 122 Ω ±1.6%
Cable 4-conductor (0.08 mm ) chloroprene shielded cable,
2

4 mm diameter by 5 m long, terminated with a connector plug


PRC03-12A10-7M
Underwater application possible by using Kyowa's cable
connection kit JB-200A
(Shield wire is connected to the case.)
*TEDS-installed models are available. Inquiries are welcome.
Mechanical Properties
Safe Overloads 300%
Frequency Response See table below.

Waterproof structure to withstand Transverse Sensitivity


Water Pressure Resistance
4% RO or less
490.3 kPa
against water pressures up to 490 kPa. Material

Case: Corrosion-resistant aluminum,
anode oxidized coated
Corrosion-resistant model with Weight Approx. 40 g (Excluding cable)
*For installation, use CC-33A adhesive or optional mount base. (See below.)
stainless steel Models
Rated Capacity
Frequency Response (At 23°C)
(Reference Value)
ASW -A series are waterproof acceleration transducers ASW- 1A ±9.807 m/s2 (±1 G) DC to 40 Hz ±5%
ASW- 2A ±19.61 m/s2 (±2 G) DC to 60 Hz ±5%
to withstand against water pressures up to 490 kPa. ASW- 5A ±49.03 m/s2 (±5 G) DC to 100 Hz ±5%
Even small-sized, these acceleration transducers ASW-10A ±98.07 m/s2 (±10 G) DC to 150 Hz ±5%
ensure reliable measurements under harsh operating ASW-20A ±196.1 m/s2 (±20 G) DC to 250 Hz ±5%
Note: The acceleration transducer is subject to a constant acceleration in
environments. In addition, corrosion-resistant version the direction of gravity, therefore measurement is restricted, taking
with stainless steel case is also available. into account this vertical movement (9.807 m/s2).
For the ASW-1A, if sensitivity for vertical acceleration is set in line
with the direction of gravity, then the rated capacity will be exceeded Acceleration
in the + direction. As long as the safe overload rating is not exceeded, Transducers
there will be no damage, but characteristics will be outside the
guaranteed range. Outline
■Dimensions ■Mount Base

General
18

(ASW-A)

18 (ASW-A)
Piezoelectric
6
8

φ34
M3 φ20 Gyro
M5 d=5 2 M3 thru-hole
φ20 2 3.4 drilled
φ6 counterbore d=4
2 3.4 drilled 11.6
2 3.4 drilled
φ6 counterbore d=6
60

4×M3 d=4
φ34
28
24
12

11.6
11.6 28
Sensitive Axes Connector plug
PRC03-12A10-7M DK-1C DK-1D
Weight: Approx. 5.3 g Weight: Approx. 13 g
Aluminum Aluminum

●Dynamic measurement

ASW-A
Recommended
products for Strain Amplifier Signal Conditioner Compact Recording System Sensor Interface
combination DPM-900 series CDV-900A EDX-10 series PCD-400A/430A
→ 3-5 → 3-9 → 3-49 → 3-78 2-128
2 ASQ-D
-129 Servo Type Acceleration Transducer
●9.807 to 49.03 m/s2
●Measurement of minute vibrations
●IP67

Specifications
TRANSDUCERS

Performance
Rated Capacity See table below.
Nonlinearity Within ±0.03% RO*1
Hysteresis Within ±0.05% RO*1
Rated Output ±5 V (10 V) ±5% *2
Environmental Characteristics
Safe Temperature -20 to 80°C
Compensated Temperature -10 to 60°C
Temperature Effect on Zero Within ±0.05% RO/°C
Temperature Effect on Output Within ±0.05%/°C
Electrical Characteristics
Power Supply ±11 to ±16 VDC, 40 mA or less (±12 V recommended)
Highly sensitive measurement of minute vibration Supplied from dedicated signal conditioner VAQ-700A,
if used.
Most suitable for vibration measurement of Cable N-41: (Optional Accessory) (For connecting ASQ-D and VAQ-700A)
6-conductor (0.2 mm2) vinyl shielded cable,
vehicles, structures and the ground 5.8 mm diameter by 50 m long
(Sensor side: 272FCW-12P)
●Acceleration measurement in a range of DC to (Measuring instrument side: PRC03-12A10-7M)
100 Hz is possible. (If desired, a model covering a N-42: (Optional Accessory)
range of DC to 300 Hz is available.) (Sensor side: 272FCW-12P)
●Compact & lightweight while ensuring high (Measuring instrument side: Bared at the tip)
accuracy and high output 1-G cancel cable: (Optional Accessory)
(WITCO OF JUPITER DENTSU CO., Ltd.)
Unlike conventional strain-gage acceleration 6-conductor (0.2 mm2) vinyl shielded cable,
5.8 mm diameter by 40 cm long
transducers, the acceleration transducers have a (Sensor side: 272FCW-12P)
servomechanism that ensures accurate, stable and (Measuring instrument side: 272MCW-12P)
reliable measurement of minute vibration with high
Mechanical Properties
sensitivity. A dedicated VAQ-700A signal conditioner
Frequency Response DC to 100 Hz (Sensitivity deviation ±10%)
is available as the mating instrument. (DC to 300 Hz available on request*1)
Measuring targets include vibration generated by Transverse Sensitivity 0.3% RO or less*2
running vehicles, earthquake or wind in structures and Degree of Protection IP67 (IEC 60529)
the ground as well as general low-frequency vibration. Weight Approx. 220 g (Excluding cable)
*1 Inspect by applying the current to a single coil.
*2 Inspect with ±1G (inclination).
Standard Accessories Hexagon socket head bolts (M4, length: 25) × 2
■Dimensions
Optional Accessories Connection cable N-41 (50 m), N-42 (5 m)
Acceleration 1-G cancel cable N-45 (40 cm)
dimensions with

Transducers Hole 4.5 mm diameter, Models Rated Capacity


Min. mounting
the cable bent

counterbore 8 mm diameter
and 16 mm deep ASQ-D-1 ±9.807 m/s2 (±1 G)
(70)

Outline ASQ-D-2 ±19.61 m/s2 (±2 G)


ASQ-D-5 ±49.03 m/s2 (±5 G)

6-conductor shielded cable,


General 5.8 mm diameter
(32)

22 22 50 m

Piezoelectric
(75)

6-conductor shielded cable,


ASQ-D 5.8 mm diameter Connection cable N-41 (Option)
(Compatible with VAQ-700A)
(40) (400) (40)
Gyro

6-conductor shielded cable,


1-G cancel cable N-45
Sensitive Axes

5.8 mm diameter
(Option)
5m Bared at the tip
32.5

(Note) Allow the ASQ-D to be connected directly to


the N-41 or N-42.
(N-45 is required for acceleration Connection cable N-42
32.5 measurement in gravitational direction.) (Option)

■Example of basic structure of servo type acceleration transducer


With the basic structure shown, an applied acceleration
displaces the weight from the neutral position. The
displacement sensor detects the displacement quantity
and sends via the servo amplifier the signal to the
drive coil that is fixed to the weight support. When
the signal current flows to the drive coil placed in a ●Dynamic measurement /
Servo amplifier Static measurement
magnetic field generated by the permanent magnet,  
the electromagnetic force returns the weight to the Permanent magnet
original position. Since the current is proportional to
the applied acceleration, a proportional voltage to the
Drive coil Displacement sensor ASQ-D
Weight Recommended
acceleration is output from both ends of the resistor products for
inserted in the current loop. combination VAQ-700A

2-129 → 2-130
VAQ-700A
ASQ Dedicated Conditioner
●Simultaneous measurement of  
 acceleration, velocity and displacement 2-130

TRANSDUCERS
Signal conditioners allow acceleration, velocity and displacement to be
measured synchronously
●Easy-to-read LED indicator
●Single channel type. Multiple units are accommodated in a portable housing case for multi-channel measurement.
The 1-channel signal conditioner enables simultaneous measurement of acceleration, velocity by 1-time integration
and displacement by 2-time integration.

Specifications
Applicable Transducers ASQ-D-1 ASQ-D-2 ASQ-D-5
Number of Measuring Channels 1
Measuring Modes Simultaneous measurement and output of acceleration, velocity and displacement
Acceleration Measuring Range ±9.807 m/s2 (±1 G) ±19.61 m/s2 (±2 G) ±49.03 m/s2 (±5 G)
Range Select 0.01, 0.1, 1 G, OFF 0.02, 0.2, 2 G, OFF 0.05, 0.5, 5 G, OFF
Calibration Linked with selected range × 0.51
Accuracy ±0.5% FS to reading with both measuring range and calibration
Frequency Response DC to 300 Hz (±5%) in DC acceleration mode, 0.1 to 300 Hz (±5%) in AC acceleration mode
Velocity Measuring Range ±100 cm/s ±200 cm/s ±500 cm/s
Range Select 1, 10, 100 cm/s, OFF 2, 20, 200 cm/s, OFF 5, 50, 500 cm/s, OFF
Calibration Linked with selected range × 0.5 Acceleration
Accuracy ±1% FS to reading with both measuring range and calibration Transducers
Frequency Response 0.1 to 100 Hz (±5%)
Displacement Measuring Range ±100 mm ±200 mm ±500 mm Outline
Range Select 1, 10, 100 mm, OFF 2, 20, 200 mm, OFF 5, 50, 500 mm, OFF
Calibration Linked with selected range × 0.5
Accuracy ±1% FS to reading with both measuring range and calibration General
Frequency Response 0.1 to 60 Hz (±5%) (1 to 60 Hz, ±0.5% with a maximum sensitivity selected for the measuring range)
Output ±10 V (Load 5 kΩ or more)
Operating Temperature −10 to 50°C Piezoelectric
Power Supply 100 V AC or 12 VDC
Dimensions & Weight 49 W × 128.5 H × 262.5 D mm, approx.1.4 kg
Gyro
Standard Accessories AC power cable P-16 (With a conversion adapter CM-52), output cable U-58 (3 PC.), fuse, miniature screwdriver,
Instruction Manual
Optional Accessories Housing case YC-A (Page 3-21)

■Dimensions

49 2 φ3
8.5

111.5
122.5
128.5

262.5 13 48.6
8.5

2-130
2 ASPA-A/ASPB-A
-131 Piezoelectric Acceleration Transducer (Built-in Amplifier)
●2200 m/s2
TRANSDUCERS

Specifications
Rated Capacity ±2200 m/s2
Voltage Sensitivity 1.0 mV/m/s2 ±10%
Resonant Frequency Approx. 45 kHz
Frequency Response (±1 dB) 3 to 12000 Hz
Frequency Response (±3 dB) 1.5 to 16000 Hz
ASPA-A
Impact Resistant 10000 m/s2
Operating Temperature -30 to 110°C
Transverse Sensitivity 5% RO or less
Output Impedance 100 Ω or less
Weight ASPA-A-200: Approx. 2 g
ASPB-A-200: Approx. 3 g
Case Material Titanium
Mounting Screw Female screw (M3×0.5, depth 2)
ASPB-A
Power Supply 15 to 25 VDC, 0.5 to 5.0 mA
Cable Dedicated cable, length approx. 2 m
Sensor side: C29-104P
Measuring instrument side: Miniature connector
(Shield wire is connected to the case.)
Wide measurement range, capable Standard Accessories Miniature BNC conversion connector
of measuring slight through to high Optional Accessories Insulated stad

accelerations. *Acceleration (m/s2)


= Output voltage from sensor (mV) ÷ Voltage sensitivity (mV/m/s2)

●High sensitivity, small size


●Capable of measurement of wide band, low to
To Ensure Safe Usage
high frequencies
●High mechanical strength Before measuring data by using the CCA-40A or CCA-
●Environmentally-resistant 40A-F, insulate the mounting surface between the
transducer and target object.
■Dimensions
Detection direction arrow
Acceleration x9 on the cylindrical surface
He
Transducers

φ6.9
10.25

Outline
C29-103R
5.75

(Tajimi)
(4.2)

General C29-103R
(3.1)

(Tajimi)
9.2
11.5

Piezoelectric φ8.8
φ6
(2.3)
0.3

φ7.8
0.25 (4.5) 6.75

Gyro
11.5
Hex7

φ8.5
2.5

M3 0.5 depth 2
Detection direction arrow
on the cylindrical surface

M3 0.5 depth 2

ASPA-A ASPB-A

●Dynamic measurement

ASPA-A/
ASPB-A
Recommended
products for
Strain/Voltage/Acceleration
Measurement Card
+ Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A EDX-200A EDX-100A EDX-5000A

2-131 → 3-74 → 3-55 → 3-63 → 3-68


ASPC-A/ASPD-A
Piezoelectric Acceleration Transducer (Built-in Amplifier)
2-132
●Simultaneous measurement of acceleration
in X, Y and Z directions

TRANSDUCERS
●360 to 4500 m/s2
ASPC-A Specifications
Rated Capacity See table below.
Voltage Sensitivity See table below.
Resonant Frequency Approx. 35 kHz
Frequency Response (±1 dB) 1 to 5000 Hz
Frequency Response (±3 dB) 1 to 8000 Hz
Impact Resistant 30000 m/s2
Operating Temperature ASPC-A-30/ASPC-A-300:
-50 to 110°C
(With operating power supply: 0.5 to 5 mA)
ASPC-A ASPD-A -50 to 70°C
(With operating power supply: 0.5 to 10 mA)
Measuring instrument side's operating
temperature: -20 to 60°C
ASPC-A-30-ID/ASPC-A-300-ID:
-40 to 85°C
(With operating power supply: 0.5 to 5 mA)
Wide measurement range, capable -40 to 70°C
of measuring slight through to high (With operating power supply: 0.5 to 10 mA)

accelerations.

Measuring instrument side's operating
temperature: -20 to 60°C
Transverse Sensitivity 5% RO or less
●High sensitivity, small size
Output Impedance 1000 Ω or less
●Capable of measurement of wide band, low to
Weight Approx. 11 g (Excluding cable)
high frequencies
Case Material Titanium
●High mechanical strength
Mounting Screw Female screw (M5×0.8, depth 3.5)
●Environmentally-resistant
Power Supply 21 to 24 VDC, 0.5 to 10 mA
Cable Dedicated cable, length approx. 3.3 m
Sensor side: DR-4S-1
Measuring instrument side: BNC connector (BNC163)
(Shield wire is connected to the case.) Acceleration
Voltage Sensitivity Transducers
Models Rated Capacity (±10%) TEDS Sensor ID TEDS (IEEE1451.4)
ASPC-A-30-ID ±360 m/s2 10 mV/m/s2 ✔ (ASPC-A-30 -ID/ ASPC-A-300 -ID only)
Outline
ASPC-A-30 ±400 m/s2 10 mV/m/s2 −
Optional Accessories Mount base
ASPD-A-45-ID ±450 m/s2 10 mV/m/s2 ✔
ASPD-A-45 ±450 m/s2 10 mV/m/s2 − *Acceleration (m/s2)
ASPC-A-300-ID ±3600 m/s2 1.0 mV/m/s2 ✔ = Output voltage from sensor (mV) ÷ Voltage sensitivity (mV/m/s2) General
ASPC-A-300 ±4000 m/s2 1.0 mV/m/s2 −
ASPD-A-450-ID ±4500 m/s2 1.0 mV/m/s2 ✔
ASPD-A-450 ±4500 m/s2 1.0 mV/m/s2 −
Piezoelectric

To Ensure Safe Usage


Gyro
Before measuring data by using the CCA-40A or CCA-
40A-F, insulate the mounting surface between the
transducer and target object.

2-132
2-133
ASPD-A Specifications
Performance
Rated Capacity See table on the previous page.
Voltage Sensitivity See table on the previous page.

Environmental Characteristics
Mechanical Properties
Frequency Response (±5 dB) ASPD-A-45 (-ID):



(±5%) (X, Y): 2 to 7000 Hz
(Z): 2 to 10000 Hz
(±3 dB) (X, Y): 0.5 to 10000 Hz
Operating Temperature ASPD-A-45 (-ID): (Z): 0.5 to 18000 Hz
-50 to 110°C ASPD-A-450 (-ID):
(±5%) (X, Y): 2 to 10000 Hz
TRANSDUCERS

(With operating power supply: 2 to 5 mA)


-50 to 80°C (Z): 2 to 15000 Hz
(With operating power supply: 2 to 10 mA) (±3 dB) (X, Y):0.5 to 1500 0Hz
ASPD-A-45-ID: (Z) :0.5 to 20000 Hz
-40 to 85°C Resonant Frequency 55 kHz or more (Z axis)
(Operating temperature of TEDS) Impact Resistant ±30000 m/s2
ASPD-A-450 (-ID): Transverse Sensitivity 5% RO or less
-50 to 120°C Case Material Titanium
(With operating power supply: 2 to 5 mA) Dimensions 10 W ×10 H ×10 D mm
-50 to 80°C (Excluding protrusions)
(With operating power supply: 2 to 10 mA) Weight Approx. 4.4 g (Excluding cable)
ASPD-A-450-ID:
-40 to 85°C Other
(Operating temperature of TEDS) Mounting Screw Female screw (M3 × 0.5, depth 2)
Attached Screw Male screw (M3 × 0.5 × 4)
Electrical Characteristics
Output Impedance ASPD-A-45 (-ID): 500 Ω or less Standard Accessories
ASPD-A-450 (-ID): 100 Ω or less Dedicated cable SA11ZSCA-01B
Power Supply 21 to 30 VDC, 2 to 10 mA Attached screw (M3 × 0.5 × 4)
Cable Dedicated cable (SA11ZSCA-01B), length approx. 3.3 m Dedicated mount base
(Measuring instrument side's operating temperature: -20 to 60°C)
Sensor side: CZ663
Measuring instrument side: BNC connector
(Shield wire is connected to the case.)

■Dimensions

Y
14.2

X
Acceleration
Transducers
Y
Outline
X
Y
(9.5) 14.2
Y

10

General
X
Z
X
14.2

Piezoelectric
(6.5) 10

Z
Gyro Z
X Z
10

DR-4S-4
X

CZ710
M5 0.8 depth 3.5 or more
Gasket M3 0.5 depth 2

ASPC-A ASPD-A

●Dynamic measurement

ASPC-A/
ASPD-A
Recommended
products for
Strain/Voltage/Acceleration
Measurement Card
+ Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A EDX-200A EDX-100A EDX-5000A

2-133 → 3-74 → 3-55 → 3-63 → 3-68


AMAS-A
Small-sized Accelerometer
●980.7, 1961 m/s2 2-134
Specifications

TRANSDUCERS
Performance
Rated Capacity See table below.
Nonlinearity Within ±2% RO
Hysteresis Within ±1% RO
Rated Output 2 V ±20%
Peak-to-peak Sensitivity Error 4% RO or less

Environmental Characteristics
Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 60°C (Non-condensing)
Temperature Effect on Zero Within ± 0.5% RO / °C
Temperature Effect on Output Within ±1% /°C
Electrostatic Withstand Voltage 4 kV
Electrical Characteristics
Safe Excitation Dual supply: ± 7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ± 2.5 to ± 6 VDC
Single supply: 5 to 12 VDC
Current Consumption 20 mA or less (At 5 VDC)
Cable ① Sensor - relay part
7-conductor (0.04 mm2), vinyl shielded cable, 2.4 mm diameter
Small & durable accelerometers by 5 m long
② Relay part - connector
7-conductor (0.04 mm2), vinyl shielded cable, 2.4 mm
●High frequency response
diameter by 2 m long, terminated with a connector plug
●Safe overloads ±39227 m/s2 (±4000 G)
(PRC03-12A10-7M)
●No external power supply unit is necessary. *Shield wire is not connected to the case.
(When using the Strain/Voltage/Acceleration
Mechanical Properties
Measurement Card CVM-41A and A/D Converter
Safe Overloads ±39227 m/s2 (±4000 G)
Card AD-40AS) Transverse Sensitivity ±4% RO or less
Frequency Response DC to 2000 Hz (Sensitivity deviation: ±10%)
Weight Approx. 5 g (Excluding cable)

Models Rated Capacity


AMAS-A-100 ±980.7 m/s2 (±100 G)
AMAS-A-200 ±1961 m/s2 (±200 G)
■Dimensions Acceleration
Transducers
15

13.5 2 φ1.8 Outline


Sensitive Axis

Sensor
General
11

Piezoelectric
6.3

(5 m)
Gyro

(2 m)
23

65

Connector plug
Relay part PRC03-12A10-7M
12

●Dynamic measurement

AMAS-A

Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A
→ 3-74 → 3-77 → 3-55 → 3-63 → 3-68 2-134
2 AMA-A
-135 Small-sized Triaxial Accelerometer
●Simultaneous measurement of acceleration
in X, Y and Z directions
TRANSDUCERS

●19.61 to 1961 m/s2

AMA-A-2/5 Specifications
Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO (100, 200: Within ±2% RO)
Hysteresis Within ±1% RO
Rated Output 2 V ±10%
Peak-to-peak Sensitivity Error 4% RO or less

AMA-A-10-S1 Environmental Characteristics


Safe Temperature -20 to 80°C (Non-condensing)
Compensated Temperature -10 to 60°C (Non-condensing)
Temperature Effect on Zero Within ± 0.5% RO / °C
Temperature Effect on Output Within ±1% /°C
Electrostatic Withstand Voltage 4 kV

Electrical Characteristics
Safe Excitation Dual supply: ± 7 VDC
Single supply: 14 VDC
Recommended Excitation Dual supply: ± 2.5 to ± 6 VDC
Single supply: 5 to 12 VDC
AMA-A-100/200 Current Consumption 10 mA or less (At 5 VDC)
(10-S1, 100, 200: 20 mA or less)
Cable See table below.

Mechanical Properties
Safe Overloads See table below.

Compact & lightweight Transverse Sensitivity


Frequency Response (23°C)
4% RO or less
DC to 500 Hz (Sensitivity deviation: ±10%)
acceleration transducer enduring (10-S1: DC to 200 Hz)
Weight See table below.
large overloads Note: The acceleration transducer is subject to a constant acceleration
in the direction of gravity, therefore measurement is restricted,
●Compact and triaxial taking into account this vertical movement (9.807 m/s2).
●High frequency response
Standard Accessories
Acceleration ●No external power supply unit is necessary. (Using
Relay cable AMA-A-M-S2K (AMA-A-10-S1)
Transducers EDX's conditioner card CVM-41A or AD-40AS)
Optional Accessories
●Fault diagnosis function is available (AMA-A-2, 5)
Outline Relay cables TE-55, TE-56 (AMA-A-2/5)
●Battery box for AMA is also available as an Relay cable AMA-A-M-S2K (AMA-A-100/200)
optional accessory.
General
[Sensitive Axes] Z axis
+Z

Piezoelectric

+X
Gyro +Y
X axis
Y axis
Models Rated Capacity Safe Overloads Weight Cable

AMA-A-2 ±19.61 m/s2 (±2 G)


6-conductor (0.04 mm2) vinyl shielded cable, 2.5 mm diameter by 5
±19613 m/s2 (±2000 G) 3g
AMA-A-5 ±49.03 m/s2 (±5 G) m long

① Sensor - relay part


9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by
5 m long
AMA-A-10-S1 ±98.07 m/s (±10 G)
2
±9807 m/s (±1000 G)
2
7g
②Relay part - connector
20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter
by 15 cm long, terminated with a connector plug (HR25A-9J-20S)

① Sensor - relay part


AMA-A-100 ±980.7 m/s2 (±100 G) 9-conductor (0.04 mm2), vinyl shielded cable, 2.9 mm diameter by
5 m long
±39227 m/s2 (±4000 G) 11 g
②Relay part - connector
AMA-A-200 ±1961 m/s2 (±200 G) 20-conductor (0.09 mm2), vinyl shielded cable, 5.4 mm diameter
by 17 cm long, terminated with a connector plug (HR25A-9J-20S)

(*) Shield wire is not connected to the case.


(*) A relay cable (optional) is necessary for connecting measuring instruments.

2-135
2
■Dimensions
AMA-A-2, 5 Sensor
14
C0.5 12.5

-136

10
7
2×φ1.8

TRANSDUCERS
5.8
Relay cable (Option)
・TE-55
Cable length: Approx. 30 cm Relay part
Relay part: Dedicated connector
Measuring instrument side: PRC03-12A10-7M (50)
30

(21)
・TE-56
Cable length: Approx. 30 cm
Relay part: Dedicated connector
Measuring instrument side: PRC05-P8M

(9)
Relay part

AMA-A-10-S1 15

(7)
Sensor (5 m)

11
(13.5)
2 φ1.8

Relay part 6.5

Relay cable (AMA-A-10-S1/100/200)


AMA-A-M-S2K
Relay part: Dedicated connector
65
Measuring instrument side: PRC03-12A10-7M
(15 cm)

23
AMA-A-10
SER No.

Acceleration
12 Transducers

Outline
AMA-A-100/200 19.3
(7)

(5 m)
Sensor
General
11

(13.5)
2 φ1.8
Piezoelectric
11

Relay part Gyro

65
(15 cm)
23

AMA-A-
SER No.
12

●Dynamic measurement

AMA-A

Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A
→ 3-74 → 3-77 → 3-55 → 3-63 → 3-68 2-136
2 GSAT-A-900
-137 Three Axis Angular Rate Gyro
●±15.71 rad/s

Specifications
TRANSDUCERS

Performance
Rated Capacity ±15.71 rad/s (±900 deg/s)
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output Approx. 2.0 V

Environmental Characteristics
Safe Temperature −10°C to 60°C
Compensated Temperature 5°C to 40°C
Temperature Effect on Zero Within ±1.0% RO/°C
AMA-A-2/5 Electrical Characteristics
Safe Excitation Dual supply: ±6.0 VDC
Single supply: 12 VDC
Recommended Excitation Dual supply: ±2.5 to ±5.0 VDC
With single supply, see to the instruction manual.
No-load Output Within ±10% RO
Cable Sensor side: 9-conductor (0.04 mm2) vinyl shielded cable,
GSAT-A 2.7 mm diameter by approx. 7 m long
Relay: 4-conductor (0.05 mm2) vinyl shielded cables,
2.6 mm diameter by approx. 1 m long, terminated with
connector plugs PRC03-12A10-7M

Compact and lightweight (Shield wire is not connected to the case.)

while enabling simultaneous Mechanical Properties


Safe Overloads 1000%
measurement of angular velocities Safe Shock Resistance 9807 m/s2 (1000 G)

in 3 directions Transverse Sensitivity


Weight
10% RO or less
Approx. 10 g (Excluding cable)
Dimensions See below.
●Compact and triaxial
●High shock resistance 9807 m/s2 (1000 G) [Sensitive Axes] +Z

●Most suitable for posture measurement


●Allows AMA-A-2/5 to be mounted on the top +Y
Note: AMA-A-2/5 are compact triaxial acceleration transducers

+X
■Dimensions
Acceleration
Transducers Sensor
20 2 φ1.8 9-conductor (0.04 mm2) vinyl shielded cable,
Outline 2.7 mm diameter by approx. 7 m long
18.5
10

Centroid positions
3.3

General
7

3.3
8.7
10

Piezoelectric
8
5.4

Relay cable
Centroid of Centroid of
Gyro X-axis element Y-axis element
(12)

(100)
4-conductor (0.05 mm2) vinyl shielded cable, *1
PRC03-12A10-7M
6

2.6 mm diameter by approx. 1 m long


Centroid of
2

Z-axis element

Weight: Approx. 10 g (Excluding cables)


Cable full length: Approx. 8 m long

indicates the centroid of element.


*1 For rectangular connectors' type, its model is GSAT-A-J.

●Dynamic measurement

GSAT-A

Recommended
Strain/Voltage/Acceleration
products for Measurement Card A/D Converter Card Universal Recorder Universal Recorder Memory Recorder/Analyzer
combination CVM-41A AD-40AS EDX-200A EDX-100A EDX-5000A

2-137 → 3-74 → 3-77 → 3-55 → 3-63 → 3-68


2-138

TRANSDUCERS
Acceleration
Transducers

Outline

General

Piezoelectric

Gyro

2-138
5 ASD-B
-21 Acceleration Transducer for Crash Test
●For crash tests ●9807 m/s2, 19613 m/s2

Specifications
AUTOMOTIVE TEST EQUIPMENT

Performance
Rated Capacity See table below.
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1.2 mV/V or more
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature –20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±0.5% RO/°C
Temperature Effect on Output Within ±0.1%/°C

Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
Measures acceleration of Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
crash-test cars. (Shield wire is not connected to the case.)

●There are two types: Vertical and horizontal Mechanical Properties


●The range of recommended excitation is 2 to 10 V Safe Overloads 200%
(AC or DC), ensuring high output. Frequency Response DC to 4 kHz at 23°C
●Equips the dedicated connector for connecting (Sensitivity deviation ±5%)
the data acquisition system for crash test directly. Installation Resonance Frequency See table below.
Transverse Sensitivity 3% RO or less
●Centroid is set at the tip of mainframe for triaxial
Automotive Test Weight Approx. 1.0 g (Excluding cable)
Equipment configuration of acceleration transducers.
Sensitive
●Undamped design ensures minimal influence to Models Axis
Rated Capacity
(Reference)
Installation
Resonance Frequency
Automotive
performance the frequency response and phase characteristics. ASD-B-1KV Vertical 2
±9807 m/s (±1000 G) 23 kHz or more
test ASD-B-1KH Horizontal ±9807 m/s2 (±1000 G) 23 kHz or more
The ASD-B is a compact and lightweight undamped ASD-B-2KV Vertical 2
±19613 m/s (±2000 G) 26 kHz or more
Crash test
acceleration transducer adopting a sputter strain gage ASD-B-2KH Horizontal 2
±19613 m/s (±2000 G) 26 kHz or more
for the sensing element. It is suitable for measurement
of acceleration given to a car body or dummy in Acceleration arrow
Crash test Arrows on the case “ ”
measuring automotive crash tests.
system Considering that 3 units may be used for simultaneous Acceleration Impact Rotation
The arrow on
measurement of acceleration in 3 directions. Center of the the case is
Crash test Acceleration rotation
in accordance
The ASD-B provides the centroid at the tip of conditions
software with the
mainframe so that 3 units are arranged with their direction of
vibration centroids put nearby. acceleration.
Polarities of output
■Dimensions
2 φ1.8 2 φ1.8
10
10

Metal Sleeve Metal Sleeve


5 (Outer diameter 3) 5 (Outer diameter 3)
7.6 0.1

7.6 0.1

10 (4.5) 10 (4.5)

12.5 12.5
4.7

4.7
1

Type V Type H
2.6 6.1 2.6 6.1
4.6

4.6

Sensitive Axis Sensitive Axis

Connector plug
R05-PB5M
Center of mass Center of mass

ASD-B-1KV/2KV ASD-B-1KH/2KH

ASD-B
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
5-21 → 5-38 → 5-46 → 5-47

It requires change of the conversion cable or plug.


ASDH-A
Acceleration Transducer for Crash Test
●For crash tests ●9807 m/s2, 19613 m/s2 5 -22
Specifications

AUTOMOTIVE TEST EQUIPMENT


Performance
Rated Capacity See table below.
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
(Vertical) Rated Output 1.2 mV/V or more
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
(Horizontal) Temperature Effect on Zero Within ±0.5% RO/°C
Temperature Effect on Output Within ±0.1%/°C

Electrical Characteristics
Safe Excitation 12 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω

Measures acceleration of Output Resistance 500 to 1000 Ω


Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
crash-test cars. 7 m long, terminated with a connector plug (R05-PB5M)
(Shield wire is not connected to the case.)
●Transverse sensitivity of 1% is much less than
conventional models. Mechanical Properties
●There are two types: Vertical and horizontal Safe Overloads 200%
●Centroid is set at the tip of mainframe for triaxial Frequency Response DC to 4 kHz at 23°C
(Sensitivity deviation ±5%)
configuration of acceleration transducers. Installation Resonance Frequency See table below.
Transverse Sensitivity 1% RO or less Automotive Test
Weight Approx. 1.4 g (Excluding cable) Equipment
Automotive
The ASDH-A is a compact and lightweight undamped Models
Sensitive Rated Capacity Installation performance
Axis (Reference) Resonance Frequency test
acceleration transducer adopting a sputter strain gage ASDH-A-1KV Vertical ±9807 m/s2 (±1000 G) 23 kHz or more
for the sensing element. It is suitable for measurement ASDH-A-1KH Horizontal ±9807 m/s2 (±1000 G) 23 kHz or more
ASDH-A-2KV Vertical ±19613 m/s2 (±2000 G) 26 kHz or more Crash test
of acceleration given to a car body or dummy in ASDH-A-2KH Horizontal ±19613 m/s2 (±2000 G) 26 kHz or more
automotive crash tests.
Crash test
measuring
system
■Dimensions
Crash test
software
2 φ1.8 2 φ1.8

Metal Sleeve Metal Sleeve


(Outer diameter 3) (Outer diameter 3)
7.6

7.6
10

10

5 5

10 (4.5) 10 (4.5)

12.5 12.5
4.7
4.7

2
2.6

2.6

Type V Type H
Sensitive Axis Sensitive Axis

6.1 6.1

Center of mass Center of mass


4.6

4.6

Connector plug
R05-PB5M

ASDH-A-1KV/2KV ASDH-A-1KH/2KH

ASDH-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-22
It requires change of the conversion cable or plug.
5 ASE-A
-23 Damped Acceleration Transducer for Crash Test
●For crash tests ●980.7 m/s2 to 9807 m/s2

Specifications
AUTOMOTIVE TEST EQUIPMENT

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output See table below.
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C

Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 300 to 1000 Ω
Output Resistance 300 to 1000 Ω
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)

Mechanical Properties
Measures acceleration of car bodies, Frequency Response See table below.

components, and dummies. Transverse Sensitivity


Safe Overloads
2% RO or less
See table below.
Weight Approx. 3 g (Excluding cable)
●Lightweight and compact
Standard Accessories
Automotive Test ●Damped type ensures minimal influence of impact
Equipment Hexagon socket head bolts M1.6×8 (×2)
acceleration-initiated resonance. (Tightening torque: 0.1 N・m)
Automotive
performance ●Optional dedicated bracket enables mounting Optional Accessories
test of the transducer to pedestrian protection head Conversion cable TT-18
impactor.
Crash test

Crash test
measuring
system Models Rated Capacity Rated Output Frequency Response (23°C) Safe Overloads
DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-100 ±980.7 m/s2 (±100 G) 0.5 mV/V or more 500%
Crash test 1 kHz to 2 kHz (Sensitivity deviation±10%)
software DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-500 ±4903 m/s2 (±500 G) 1 mV/V or more 400%
1 kHz to 4 kHz (Sensitivity deviation±10%)
DC to 1 kHz (Sensitivity deviation±3%)
ASE-A-1K ±9807 m/s2 (±1000 G) 2 mV/V or more 200%
1 kHz to 4 kHz (Sensitivity deviation±10%)

To Ensure Safe Usage ■Dimensions


●When conducting the Pedestrian Head Protection
Performance Test, ground the aluminum skull 10 (30)
(Metal) portion of the head impactor and the DIS
series. The grounding is an effective measure 8
against noise caused by electric charge. The
charge is generated between the head skin
material and aluminum skull of the head
10
8

impactor resulting to adversely affect the ASE-A


output at the time of impact.
●Due to mounting holes, corners of the transducer 4 φ1.7
case is thin-walled structure. Avoid dropping or
Sensitive Axis

hitting against a hard matter. Or the case will be


deformed or damaged.
●For installation, use dedicated bolts M1.6x8 and
5

fix 2 diagonal positions.


●If this transducer is installed by adhesives, Connector plug
2.3

excessive forces to remove it results in R05-PB5M

deformation of its frame or failure. To avoid these


Center of mass
troubles, fix this transducer by dedicated bolts, if
remove transducer and repeat to use it.

ASE-A
Recommended Data Acquisition System Small-sized Data Logger Small-sized Data Logger
products for for Crash Test for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-503A DIS-618A/632A DIS-5210A
5-23 → 5-38 → 5-46 → 5-46 → 5-47

It requires change of the conversion cable or plug.


ASER-A
Damped Acceleration Transducer for Crash Test
●For crash tests ●980.7 m/s2 to 9807 m/s2
5 -24
Specifications

AUTOMOTIVE TEST EQUIPMENT


Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output See table below.
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% / °C

Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 300 to 1000 Ω
Output Resistance 300 to 1000 Ω
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)

Mechanical Properties
Measures acceleration of car bodies Safe Overloads See table below.

and dummies. Frequency Response


Transverse Sensitivity
See table below.
2% RO or less
Weight Approx. 3 g (Excluding cable)
●Because this is an oil-damped type, there is
no adverse impact from resonant output in Standard Accessories
Automotive Test
pedestrian head impact protection function Hexagon socket head bolts M1.6×8 (×2) Equipment
testing and vehicle crash testing. (Tightening torque: 0.1 N・m)
Automotive
●Compact type, therefore mounting in space-confined Optional Accessories performance
test
measurement locations used in vehicle crash testing Conversion cable TT-18
is possible
●10 V excitation voltage enables high output. Crash test

●Cable is exchangeable when damaged.


Crash test
measuring
Models Rated Capacity Rated Output Frequency Response (23°C) Safe Overloads system
DC to 1 kHz (Sensitivity deviation±3%)
ASER-A-100 ±980.7 m/s2 (±100 G) 0.5 mV/V or more 500%
1 kHz to 2 kHz (Sensitivity deviation±10%) Crash test
DC to 1 kHz (Sensitivity deviation±3%) software
ASER-A-500 ±4903 m/s2 (±500 G) 1 mV/V or more 400%
1 kHz to 4 kHz (Sensitivity deviation±10%)
DC to 1 kHz (Sensitivity deviation±3%)
ASER-A-1K ±9807 m/s2 (±1000 G) 2 mV/V or more 200%
1 kHz to 4 kHz (Sensitivity deviation±10%)

■Dimensions
Cable is exchangeable
when damaged.
To Ensure Safe Usage
10 (26)
(8) ●When conducting the Pedestrian Head Protection
Performance Test, ground the aluminum skull
8
(9.5)

(Metal) portion of the head impactor and the


DIS series. The grounding is an effective measure
against noise caused by electric charge generated
between the head skin material and aluminum
10

skull of the head impactor resulting to adversely


4 φ1.7 affect the ASER-A output at the time of impact.
Sensitive Axis

(4.3)

Connector plug
2.3

R05-PB5M

Mounting surface
Center of mass

ASER-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-24
It requires change of the conversion cable or plug.
5 ASDE-A
-25 Damped Acceleration Transducer for Crash Test
Specifications
AUTOMOTIVE TEST EQUIPMENT

Performance
Rated Capacity See table below.
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output See table below.
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C

Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
The oil damped design is least Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
affected by impact acceleration- (Shield wire is not connected to the case.)

initiated resonance. Mechanical Properties


●For crash tests Safe Overloads See table below.
Frequency Response See table below.
 Vehicle, components, and dummy acceleration
Transverse Sensitivity 2% RO or less
measurement Weight Approx. 1.2 g (Excluding cable)
●Damped type
Automotive Test Because this is an oil-damped type, there is Optional Accessories Conversion cable TT-18
Equipment little adverse impact from resonant output in
Automotive pedestrian head impact protection function
performance testing and vehicle crash safety testing.
test ●Compact & lightweight
 Mounting in limited space is possible.
Crash test ●Rated capacity: 9807 m/s2 ( 1000 G)
Safe
Models Rated Capacity Rated Output Frequency Response (23°C) Overloads
Crash test
measuring DC to 1kHz (Sensitivity deviation ±3%)
system ASDE-A-1K ±9807 m/s2 (±1000 G) 1 mV/V or more 200%
1kHz to 4kHz (Sensitivity deviation ±10%)

Crash test
software ■Dimensions
2 1.8
7.6 0.1
10

5 Metal sleeve (Outer diameter 3)

11.5 (5)
13.5

XXXXXXXXX
4.9

Sensitive Axis
1

2.6 4.5

Connector plug
R05-PB5M
4.6

Center of mass

ASDE-A
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
5-25 → 5-38 → 5-46 → 5-47

It requires change of the conversion cable or plug.


ASDR-A-1K
Damped Acceleration Transducer for Crash Test
5 -26
Specifications

AUTOMOTIVE TEST EQUIPMENT


Performance
Rated Capacity ±9807 m/s2 (±1000 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 2 mV/V or more
Peak-to-peak Sensitivity Error 1% RO or less

Environmental Characteristics
Safe Temperature -15 to 65°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±1% RO /°C
Temperature Effect on Output Within ±0.5% /°C

Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 to 10 V AC or DC
Input Resistance 500 to 1000 Ω
Output Resistance 500 to 1000 Ω
The oil damped design is least affected by Cable 4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
impact acceleration-initiated resonance. (Shield wire is not connected to the case.)

Mechanical Properties
●For crash tests
Safe Overloads 200%
 Vehicle, components acceleration measurement Frequency Response DC to 1 kHz at 23°C (Sensitivity deviation ±3%)
●Damped type 1 to 4 kHz (Sensitivity deviation ±10%)
Because this is an oil-damped type, there is Transverse Sensitivity 2% RO or less
little adverse impact from resonant output in Weight Approx. 1.2 g (Excluding cable)
Automotive Test
pedestrian head impact protection function Optional Accessories Equipment
Conversion cable TT-18
tests and vehicle crash safety tests. Automotive
●Compact, lightweight and flangeless performance
test
 Mounting in limited space is possible.
●Cable is exchangeable when damaged.
Crash test

Crash test
measuring
system
■Dimensions
Crash test
R05-PB5M software

4-conductor (0.05 mm2) vinyl shielded cable, 2.6 mm diameter

Enlarged View A
13
5

(9)
5.4

(22)
2.7

Connector plug
Sensitive Axis R05-PB5M
4.4
(1.2)

(3.6)

Center of mass
A

ASDR-A-1K
Recommended Data Acquisition System Small-sized Data Logger
products for for Crash Test for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-618A/632A DIS-5210A
→ 5-38 → 5-46 → 5-47 5-26
It requires change of the conversion cable or plug.
5 ASM-200BA
-27 Semiconductor Acceleration Transducer for Crash Test
●1961 m/s2

Specifications
AUTOMOTIVE TEST EQUIPMENT

Performance
Rated Capacity ±1961 m/s2 (±200 G)
Nonlinearity Within ±1% RO (Within ±0.5% RO optional)
Hysteresis Within ±1% RO
Rated Output 1.3 mV/V or more
Peak-to-peak Sensitivity Error 1.5% RO or less

Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±2% RO/°C
(Within ±1% RO/°C optional)
Temperature Effect on Output -0.25 to 0%/°C

Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Measures acceleration of car bodies Output Resistance 120 Ω ±20%

and dummies. Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter
by 7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)
●Compact and lightweight design (approx. 1.2 g)
causes minimal influence to the vibration mode Mechanical Properties
of a measuring object. Safe Overloads 500%
●High safe overload rating 500% Frequency Response DC to 3.5 kHz at 23°C (Sensitivity deviation ±5%)
●No damping oil resulting in no temperature Resonance Frequency 21 kHz ±10%
effects on frequency response and phase Transverse Sensitivity 3% RO (1% RO optional) or less
Automotive Test Weight Approx. 1.2 g (Excluding cable)
Equipment characteristics.
Automotive ●Undamped design ensures minimal phase shift. Optional Accessories Conversion cable TT-18
performance
test
The ASM-200BA acceleration transducer adopts
semiconductor strain gages for the sensing element. Its To Ensure Safe Usage
Crash test
compact and lightweight design less affects to vibration ●Excitation voltage should be 2 VDC.
mode of measuring objects. Thus, it is applicable to ●Use screws to mount the acceleration
Crash test various acceleration or vibration measurement. transducer. Removing the transducer mounted
measuring
system with an adhesive may give it impact, thereby
causing damage.
Crash test
software
●Bore screw holes for M1.6 or No. 0-80UNF
in the measuring object. Tightening torque
should be 0.08 to 0.1 N・m (0.8 to 1 kgf・cm).
●When mounting with screws, slightly apply
silicone oil or grease to the contact surface.
Resultant closer contact will ensure better
fixing condition.
●This transducer comes with a connector, whose
initial balance has been achieved. Therefore,
if the transducer is to be used after removal
of the connector, contact us for necessary
information.
■Dimensions
4.6 (2.5)
15
7
Metal Sleeve
(Outer diameter 2.1)
4.6
10

7.6

Connector plug
R05-PB5M
1
4.5 2 φ1.8
Sensitive Axes
Center of mass

ASM-200BA
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
5-27 → 5-38 → 5-47

It requires change of the conversion cable or plug.


ASM-1KBCV/BCH M3
Semiconductor Acceleration Transducer for Crash Test
5 -28
●For crash tests ●9807 m/s2

AUTOMOTIVE TEST EQUIPMENT


Specifications
Performance
Rated Capacity ±9807 m/s2 (±1000 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 1.75 mV/V or more
ASM-1KBCV M3
Peak-to-peak Sensitivity Error 1.5% RO or less
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±3% RO/°C
Temperature Effect on Output -0.25 to 0%/°C
Electrical Characteristics
Safe Excitation 2 VDC only
ASM-1KBCH M3 Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Output Resistance 120 Ω ±20%
Cable 4-conductor (0.08 mm2) vinyl shielded cable, 3.2 mm diameter by
7 m long, terminated with a connector plug R05-PB5M
(Shield wire is not connected to the case.)

Measures acceleration of Mechanical Properties

crash-test cars. Safe Overloads 150%


Frequency Response DC to 2.8 kHz at 23°C
(Sensitivity deviation ±5%)
●Compact and lightweight design (approx. 4 g) Resonance Frequency 35 kHz ±30%
causes minimal influence to the vibration mode Transverse Sensitivity 3% RO or less Automotive Test
of a measuring object. Weight Approx. 4.0 g Equipment
●High safe overload rating 150% Optional Accessories Conversion cable TT-18 Automotive
●No damping oil resulting in no temperature performance
effects on frequency response and phase To Ensure Safe Usage
test
characteristics.
●Undamped design ensures minimal phase shift.
●Excitation voltage should be 2 VDC.
Crash test
●Combinations of 2 sensitivity axes, horizontal ●Transducer output characteristics
(H model) and vertical (V model) to mounting *Not in accordance with the direction of acceleration
Crash test
surface, are able to configure thin-triaxial Acceleration Impact Rotation measuring
acceleration transducers. + The same system
Rotational as weight
These acceleration transducers adopt semiconductor Acceleration
center
movement Crash test
strain gages as the sensing element and are applicable input conditions software
to acceleration measurements of car bodies in crash
tests.

Transducer
output polarity (+) (+) (+)

■Dimensions
25
14
2.1
2 M1.6
Nut
12
9

3.6
Rubber cap
5
Joined surface
5.4

Connector plug
R05-PB5M
2.6
0.9

2 M1.6 cross-recessed head


Center of mass Sensitive Axes Sensitive Axes round machine screw
(ASM-BCH M3) (ASM-BCV M3)

ASM-
1KBCV/BCH M3
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
→ 5-38 → 5-47 5-28
It requires change of the conversion cable or plug.
5 ASM-A-ID
-29 Semiconductor Acceleration Transducer for Crash Test
●For crash tests ●19613 m/s2
AUTOMOTIVE TEST EQUIPMENT

Specifications
Performance
Rated Capacity ±19613 m/s2 (±2000 G)
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
ASM-A-2KV-ID Rated Output 6 mV/V or more
Peak-to-peak Sensitivity Error 1.5% RO or less
Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±3% RO/°C
Temperature Effect on Output -1 to 0% / °C
ASM-A-2KH-ID
Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Output Resistance 120 Ω ±20%
Cable 4-conductor (0.05 mm2) vinyl shielded cable, 3.2 mm diameter by 8 m
long, terminated with a connector plug 3RT01-PE7M (TEDS installed)
(Shield wire is not connected to the case.)

Measures acceleration of Mechanical Properties

crash-test cars. Safe Overloads 150%


Frequency Response DC to 2.8 kHz at 23°C
(Sensitivity deviation ±5%)
●Larger capacity and output than conventional Resonance Frequency 25 kHz ±30%
Automotive Test models Transverse Sensitivity 3% RO or less
Equipment ●Built-in TEDS for labor saving Weight Approx. 4.0 g (Excluding cable)
Automotive ●No damping oil ensures no temperature effect
performance on frequency response and phase characteristics.
test ●Undamped design ensures minimal phase shift. To Ensure Safe Usage
Crash test These acceleration transducers adopt semiconductor ●Excitation voltage should be 2 VDC.
strain gages as the sensing element and are applicable ●Transducer output characteristics
to acceleration measurements of car bodies in crash *Not in accordance with the direction of acceleration
Crash test
measuring tests. Acceleration Impact Rotation
system The same
+
Rotational as weight
center
Crash test Acceleration movement
software input conditions

Transducer
output polarity (+) (+) (+)

■Dimensions
3RT01-PE7M
(16)

Sensitive axes, serial number (44)

25
14
5.4 0.3

12
9

Connector plug
2 x M1.6 Cross-recessed
0.9

3RT01-PE7M
Sensitive Axes Sensitive Axes round head machine screw 3.6
(ASM-A-2KH-ID) (ASM-A-2KV-ID) 5

ASM-A-ID
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
5-29 → 5-38 → 5-47

It requires change of the conversion cable or plug.


ASM-1KCBV
Semiconductor Acceleration Transducer for Crash Test
●For crash tests ●9807 m/s2 5 -30
Specifications

AUTOMOTIVE TEST EQUIPMENT


Performance
Rated Capacity ±9807 m/s2 (±1000 G)
Nonlinearity Within ±1% RO (Within ±0.5% RO optional)
Hysteresis Within ±1% RO
Rated Output 1.5 mV/V or more
Peak-to-peak Sensitivity Error 1.5% RO or less

Environmental Characteristics
Safe Temperature -20 to 60°C
Compensated Temperature 5 to 40°C
Temperature Effect on Zero Within ±2% RO/°C
Temperature Effect on Output -0.25 to 0%/°C

Electrical Characteristics
Safe Excitation 2 VDC only
Recommended Excitation 2 VDC only
Input Resistance 120 Ω ±20%
Output Resistance 120 Ω ±20%
Cable 4-conductor (0.035 mm2) shielded cable, 1.7 mm diameter by
7 m long, terminated with connector plugs at both ends
(Sensor side: MR01-P4F, Measuring instrument side: R05-PB5M)
(Shield wire is not connected to the case.)
For crash tests Mechanical Properties

Cable is exchangeable when Safe Overloads 120%


Frequency Response DC to 3.5 kHz at 23°C
damaged. (Sensitivity deviation ±5%)
Resonance Frequency 30 kHz ±20% Automotive Test
●Compact and light weight design (approx. 4.3 g) Transverse Sensitivity 3% RO or less Equipment
causes minimal influence to the vibration mode Weight Approx. 4.3 g Automotive
of a measuring object. performance
Optional Accessories
●Safe overload rating 120% test
●No damping oil resulting in no temperature Triaxial mount S (MA-10A for mounting with adhesive)
Triaxial mount T (MA-10B for mounting with screws)
effects on frequency response and phase Conversion cable TT-18 Crash test
characteristics.
●Undamped design ensures minimal phase shift.
●Connector-equipped design facilitates cable To Ensure Safe Usage Crash test
measuring
exchange. ●Excitation voltage should be 2 VDC. system
●Mount for triaxial measurement is optionally ●Use screws for mounting. Mounting using an
available. adhesive may result in a shock when removing, Crash test
software
and this may lead to damage.
The ASM-1KCBV acceleration transducer adopts ●When affixing the object to be measured, use
semiconductor strain gages for the sensing element. the following screws.
Its compact and lightweight design less affects Metric course thread M2.5, M2.6, or unified
to vibration mode of measuring objects. Thus, it screw thread No.2-56UNC
is applicable to various acceleration or vibration ●When mounting with screws, slightly apply
measurement. silicone oil or grease to the contact surface.
Resultant closer contact will ensure better
fixing condition.
■Dimensions

12.5 (13.1)
7.7 6

4 2.8
2 0.5
12.4
16

7.4

Connector plug
R05-PB5M
φ6.5

Sensitive Axes 2.5 Dedicated Center of mass


Connector

ASM-1KCBV
Recommended Data Acquisition System
products for for Crash Test Data Logger for Crash Test
combination DIS-7000 Series DIS-5210A
→ 5-38 → 5-47 5-30
It requires change of the conversion cable or plug.
You can count on Kyowa.
Feel free to contact us,
if there is something you would like to know or
do not understand about Kyowa products.

Applications of the automotive

Applications of
Applications ofthe
theenergy industry
automotive

+
Y

-
Z X
- +

ZSE ELECTRONIC MESS-SYSTEME &


SENSORTECHNIK GmbH
Postfach 1830 I 74308 Bietigheim-Bissingen
Telefon: 0 71 42 68 45 I Fax: 0 71 42 69 97 DOWN
e-mail: info@zse.de I www.zse.de

You might also like