FUNCTIONAL
TEST PROCEDURE
FTP 628
FOR
INDICATOR, OTL PRESSURE
AEROSONIC P/N 66745-0111
PIPER P/N 55571~2
PREPARED BY Ax! Ze, DAT ee
APPROVED BY &4w2d DATE 2-5-4
QA APPROVAL DATE a:#-2AEROSONC cone
REVISION PAGE
DESCRIPTION OF CHANGE
Orig.FIP NO. 628
AEROSONIC core ee
INTRODUCTION
1,1 Sgope: This procedure defines the requirements
for Individuel Tests to be conducted on the Indicator
P/N 66745-0111 (Piper P/N 55571-2) at the manufacturers
facility.
ie Specifications:
Aerosonic Drawing # 22968
Piper Drawing # 55571-2
GENERAL SPECIFICATIONS
Indicators shall be of new manufactur,
External wiring shall be in accordance with
Figure 1.
Supply current shall be 0,03 Amps max,
Range shall be 0 to 125 PSI.
2.5 Dials and pointers shall conform to Aerosonic
outline draving # 22948.
2.6 Weight shell not exceed 8 oz.
FUNCTIONAL TEST
3.1 Standard Test Conditions:
Unless othervise specified ell tests shall be conducted
at an atmospheric pressure of 29.92 IN. HG., = temp-
erature of approximately 25° C and a relative humidity
not greater then 85%. When tests are conducted vith
conditions substantially different than specified,
allovences shell be made for variations from th
specified conditions,
3.2 Vibration:
Unless otherwise specified, the unit under teet shall
be lightly tapped or vibrated before @ reading is
taken.
3.3 Test Equipments
3.3.1 0 tO 10 Volt DC Power Supply (Power Designs
Ine. Model 5005S or equivalent.
3.3.2 Fluke DRM 6050A or equivalent.AEROSONIC core eee te
SCALE ERROR:
Seale error readings shall be taken at the points
specified in Table 1. Readings shall be taken and
recorded for both increasing and decreasing application
of voltage and the readings shall not exceed the tol-
erances epecified.AEROSONIC com
FIGURE 1,
DKaToR
TABLE 1.
Test pointe Desired
SL.
0
2
50
75