Technical Service Bulletin

TSB-2013-01-VE-002

Manufacturer Product Line Engine Model Page


Volvo Excavator D7E EAE2 1
Component Group Model Series Date
Electrical EC290BPrime 17------- 30.01.2013

Subject
To share the about battery charging alarm.

Failure/Problem
Battery charging alarm.

Symptom
Battery charging alarm.

History
Machine was stopped for a long time.

Cause & analysis

- Battery
- Alternator
- Belt
- Cable between alternator and battery
- VECU not good, IECU not good

Action
We start rung the machine with boosted batteries. And then we measured the alternator B1+ voltage. It was
16 voltages. Charging alarm still on IECU, even if engine was running. Because, fed voltage for alternator
wasn’t enough. So, alternator wasn’t working. Changed the new batteries. And then, tested run the machine.
Battery charging alarm was disappeared on IECU. It was normal.

Part number responsible Part number replaced


Parts no. Description Qty Parts no. Description Qty

Picture

Remark

Prepared by: Zaw Htun (2) Title: Junior Mechanic


Acknowledged by: U Aung Toe Title: Section Head
Company: UMG Myanmar (PHK)

Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.