Professional Documents
Culture Documents
Manual Instalation and Use - English
Manual Instalation and Use - English
Thank you for purchasing Rastre Curve 2Plus , help us improve even more .
Follow the instructions in the pdf document as well as the installation, setup and use demo
videos that came with the DVD
Any questions or information please contact us
Join our portal,l, ask questions, learn, exchange knowledge and exchange and download curves in
our bank of curves (soon Many curves).
www.rastrecurve.com
Presentation :
The Rastre Curve 2PLUS is a tracker device defects, commonly known as curves signature
analyzer, or Curve Tracer containing Analysis features characteristic curves. Curve analysis is a
powerful testingg technique for finding PCB faults : an AC voltage at a given frequency is injected
into a pin at a given point on a circuit board and the analyzer injects voltage and current resulting
in a curve shape on an XY screen. This display is a "signature" of circuit
circuit operation, which can be
compared to a known standard or "good" card. If the patterns do not match, the test board is
defective. For example, when testing a point, a capacitor will show an ellipse, a resistor will show
a straight line at an angle, a diode
ode shows the characteristic exponential curve, and so on.
.
Signature analysis is popular in bench testing situations because it does not require knowledge
of circuit operation and can thus be used to expedite equipment analysis and
maintenance. The Rastre Curve 2PLUS represents a significant advantage over existing signature
analysis tools: it costs cheaper compared to existing signature analysis instruments and the
band frequency of the test signal is injected by a very short time (1.5 ms ) not to damage
sensitive circuits ... In this software that comes with the acquisition device , there are 4 test
profiles:
Low Power: Indicated for boards where voltage / frequency are low . Also suitable for boards
with high capacitance level, because the inserted frequency is 4 HZ.
Normal Power : Suitable for most tests, this option is already defaulted to start future tests, you
can change to your liking.
Automatic Power: Indicated when the board to be measured is unknown, the current in this
option willl be limited by the measured circuit.
Maximum Power: Suitable for power circuits, transistors, amplifiers, etc. In this option
the frequency will be higher.
With these options you can change as you like during the test and during the
memorization, the way that the results can be translated into more accurate values. "Curve
signature" and other waveforms can be saved, retrieved and compared to make this a valuable
debugging tool. Allowing a wider range of useful measures.
All functions of the instrument can be controlled via a USB2 connection . 0 from a computer.
Through our software that can be installed on Windows XP SP3 operating systems up to
Windows10, 32bits or 64bits.
Content:
1- Data Acquisition Device
2- Pairs of Probes
1- Yellow Pulse Test Cable
1- USB cable
1- DVD Containing Software and License + PDF manuals
Features:
Channels: 3 , 2 for comparison and memorization and testing, and 1 for firing
transistors, triacs , scr , photocouplers , etc.
Photo memorization, point-to-point,
point, and three-point
three capture mode.
USB Power Only
Test Profiles: 4 (Low, Normal, Maximum and Automatic Power)
Maximum Test Voltage up to 2.4 vp (4.8 vpp )
Max Current 10mA
Test Voltage Application Time: 1.5 ms
NOTE: Testing should be done with the board and / or modules off
of and if capacitors are charged
they should be discharged.
Installation:
1- Click on the installation program located on the accompanying DVD:
DVD
2- Read the Agreement, and to proceed select “I accept the terms of the agreement” and click
next.
8- Wait...
Drive installation:
During installation the installer configures the drive automatically, if Windows does not
recognize the drive when plugging the Rastre 2Plus into the USB port, do the following:
5- Select the drive folder that is in the DVD drive or select the folder in which this software
installation path " C: \ RastreCurve2PLUS \ RastreCurve \ driver " and click OK
Execution:
1- Click on the icon of RastreCurve
RastreCur 2PLUS, in the area of work or in the start menu.
menu
2- In the first run will ask your data for system registration, after registration will not appear
this screen. Here enter your name in field 1 , enter your serial in field 2 the same as
described on the DVD VD or Cover or along with your software purchase documentation. Click
OK to proceed. Ready your software will be registered!
registered
Index 1 = This button starts the tests selected by the memorized curve or virtual board, which
should be compared to any defective physics.
Index 2 = This button gives you the option to edit or re-map
map the curves already saved in the
selected project.
Index 3 = This button when selected will allow you to rename the selected curve.
Index 4 = This button when selected allows you to delete the selected curve.
Index 5 = This button when selected returns to the main menu
Index 1 = Button to exit this screen and return to the previous menu.
Index 2 = Button where you can modulate as needed, in three options:
Low Power : Indicated for boards where the voltage / frequency should not be high as boards
containing BGAs . Also suitable for boards with high capacitance level, because
the inserted frequency is 4 HZ.
Normal Power : Suitable for most tests, this option is already defaulted to start future tests,
you can change to your liking.
Automatic Power : Indicated when the board to be measured is unknown, the current in this
option will be limited by the measured circuit.
Maximum Power : Suitable for power circuits, transistors, amplifiers, etc. In this option
the frequency will be higher.
Index 3 = Here you select whether you want to hear a beep when the curve is different or equal
within tolerance.
Index 4 = Here you can export a curve image in BMP format and save it to your computer.
Index 5 = Here you willl select the folder where the curve image will be saved.
Index 6 = Here the comparison icon if the curve is within the established tolerance limit.
Index 7 = Curves, or analog signature of available channel 1 and channel2.
Index 8 = Graph curves: Generated d + channel1 + channel2.
Index 9 = Channel 1 curve.
Index 10 = Channel 2 curve .
Index 11 = Here is a caption to identify the channels, and you can also change the color of the
curves of each channel by clicking on the color caption.
caption
Index 1 = Here you set the firing angle of the first pulse.
Index 2 = Here you set the duration of the first pulse, defined in ms ( milliseconds )
Index 3 = Here you set the firing angle of the second pulse.
Index 4 = Here you set the duration of the second pulse, defined in ms ( milliseconds )
Index 5 = First pulse in the configuration chart.
Index 6 = Second pulse on the configuration chart.
Index 7 = Button to start or stop pulse generation.
Index 8 = VI curve of the trigger generation.
Index 9 = Button to return to the previous menu .
Index 10 = Graph curves: Generated + channel1 + channel2.
Index 11 = Channel 1 curve.
Index 1 2 = Channel 2 curve .
Index 1 3 = Channel
nnel 1 trigger capture button
Index 1 4 = Channel 2 trigger capture button
Index 1 5 = Memory / Channel Comparison Percentage1
Index 1 6 = Memory / channel comparison percentage2
Result:
Result:
Index 1 = Channel 1 curves in this photo in green and memory in lilac, visual comparison screen.
Index 2 = Channel 2 curves in this photo in green and memory in lilac, visual comparison screen.
Index 3 = Percentage of comparison between channel 1 and memory captured by button 5 .
Index 4 = Percentage of comparison between channel 2 and memory captured by button 7 .
Index 5 = Channel 1 capture button, saves curve in memory to be compared on same channel.
Index 6 = Button where you can modulate as needed, in three options:
Low Power : Indicated for boards where the voltage / frequency should not be high as
boards containing BGAs . Also suitable for boards with high capacitance level, because
the inserted frequency is 4 HZ.
Normal Power : Suitable for most tests, this option is already defaulted to start future
tests, you can change to your liking.
Automatic Power : Indicated when the board to be measured is unknown, the current in
this option will be limited by the measured circuit.
Maximum Power : Suitable for power circuits, transistors, amplifiers, etc. In this option
the frequency will be higher.
Index 7 = Channel 2 capture button, saves curve in memory for comparison on same channel.
Index 8 = Close button of this function.
function
Index 1 = Image selection of usage examples, when selected the example image will be shown
on the index screen 2 .
Index 2 = Image shown as an example of use selected by the option in index 1 , in this case the
image channel 1 in Drain, Channel 2 in Gate and GND (black terminal) in Source.
Index 3 = Transistor switching curve, in this case in lilac is the captured memory of a Fet N
channel transistor and the e curve, green the actual channel 1.
Index 4 = Percentage of comparison between memory and channel1.
Index 5 = Curve capture button generated in channel 1 for comparison.
Index 6 = Button where you can modulate as needed,
needed, in three options:
Low Power : Indicated for boards where the voltage / frequency should not be high as
boards containing BGAs . Also suitable for boards with high capacitance level, because
the inserted frequency is 4 HZ.
Normal Power : Suitable for most tests, this option is already defaulted to start future tests,
you can change to your liking.
Automatic Power : Indicated when the board to be measured is unknown, the current in this
option will be limited
imited by the measured circuit.
Maximum Power : Suitable for power circuits, transistors, amplifiers, etc. In this option
the frequency will be higher.
Index 7 = Selection knob if you want to beep when the curve is identical high pitch, different
curve low pitch.
Index 8 = Button to exit the function.
function
Index 1 = Visualization
on of the generated and converged signal.
Index 2 = Button where you can modulate as needed, in three options:
Low Power : Indicated for boards where the voltage / frequency should not be high as
boards containing BGAs . Also suitable for boards with high capacitance level, because
the inserted frequency is 4 HZ.
Normal Power : Suitable for most tests, this option is already defaulted to start future
tests, you can change to your liking.
Automatic Power : Indicated when the board to be measured is unknown, the current in
this option will be limited by the measured circuit.
Maximum Power : Suitable for power circuits, transistors, amplifiers, etc. In this option
the frequency will be higher.
Index 3 = Setting selection, example in this case, I selected as indicated by the index 5 .A
image, (not required, indication of use only). IRF640 component, Channel 1 on pin3
(source) Channel2 on pin1 ( gate ), GND black tip on Pin2 (Drain).
Index 4 = LED finish recording indication.
indication
Index 5 = Image selection of usage examples, when selected the example image will be
shown on the index 5 .A screen .
Index 6 = Photo of component selected for editing or memorization.
memorization
Index 7 = Memory totalization indication.
indicatio
Index 8 = Actual Channel 1 Curve.
Curve
Index 9 = Color legend of the curves by clicking on the frame, and 'you can change the
colors as you wish. Index 10 = Save curve and return.
Index 11 = Go back and edit the recorded curve.
curve Index 12 = Button to record theth curve.