Professional Documents
Culture Documents
B25 RRH4x30 Field Installation Guide
B25 RRH4x30 Field Installation Guide
B25 RRH4x30 Field Installation Guide
538.5 mm
(21.2 in)
304 mm
182.4 mm
(11.97 in)
(7.18 in)
External interfaces Weight = 24 kg
(bottom of RRH) (52.9 lbs)
Important!
The Nokia B25 RRH4x30 must be installed vertically oriented with all cabling Notes:
interfaces at the bottom. Upside down and horizontal mounting are not allowed. 1. All specifications are with the solar shield installed.
The B25 RRH4x30 may also be referred to as UHFA. 2. Dimensions do not include connectors or other small protrusions.
Intended audience
This document is intended for field construction personnel during the installation of hardware for Nokia customers. This product must only be installed
by a Qualified Person (a person designated by the employer; and by reason of training, experience, or instruction has demonstrated the ability to
perform safely all assigned duties; and, when required is properly licensed in accordance with federal, state, or local laws and regulations). Proper safety
polices and practices must be adhered to. Risks are discussed in more detail in the LTE B25 RRH4x30 – Site Preparation Guidelines (3MN-02023-0001-
RJZZA) and LTE Remote Radio Head (RRH) - Safety Guidelines (3MN-01725-0002-RJZZA) documents available to Nokia customers at
http://support.alcatel-lucent.com/. No other use of this document is approved.
Legal notice
Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners.
The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein.
© 2017 Nokia.
Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone
outside Nokia without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Required parts
Part No. 3JR53349AA, 3JR53349AB Part No. 3JR58716AA
Qty. 1 Qty. 1
Comments Includes RRH with solar shield Comments Optional: Required only for wall
mounting
Qty. 1 Qty. 1
Comments Required for wall and pole Comments Optional: Required only for pole
mounting mounting
Qty. 1 Qty. 1
Comments 1 required per RRH, can be Comments 1 required per RRH, used with
reused customer-provided power cable
Description Spare solar shield kit Description Ferrite core, snap-on, round
Qty. 1 Qty. 1
Comments Optional: Required for Comments 1 required per RRH with CLEI
replacement of damaged solar code CRMRY00DRA. If CLEI
shield; includes fasteners code is not CRMRY00DRA,
then ferrite is not required.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 2 of 18
Required parts (continued)
Part No. 301022679 Part No. Part number depends on length
required and connector type
Includes 2 AWG and 6 AWG 2-
Description Ground lug kit (kit WES bag) hole lugs; M6 bolts, plain, and Description RF cable, coax, 7/16 DIN male Includes coaxial cable with 7/16
Qty. 1 lock washers; and Torx security Qty. 2 or 4 DIN male connectors
bit
Comments Required for PE ground Comments 1 required for each antenna
connection used
Description Optical fiber, LC-LC connectors Description Weatherproofing kit for RF cable
connectors and ferrite
Qty. 1 or 2 Qty. 1
Comments 1 required per CPRI connection, Comments Required for ferrite, optional for
must be same length +/- 100 m RF cable connectors
Description R2CT weatherized plug Description User alarm cable, 4 pair, circular
DIN male on one end
Qty. 1 or 2 Qty. 1 (optional)
Comments 1 required per CPRI connection Comments Required for user alarms
Description R2CT plug extension accessory Description AISG cable, 8-pin circular DIN
Qty. 1 or 2 (optional) Qty. 1 (optional)
Comments 1 required per R2CT plug when Comments Required for AISG daisy chain
simplex optical fiber fan out is connection
between 100 mm and 500 mm
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 3 of 18
External interfaces
Bottom view
Solar shield
Important!
Connect CPRI1
port to LTE
BBU
Attention: For all product-specific figures in this document, the colors depicted are for identification purposes only. Final product colors may be different.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 4 of 18
1: Unpack RRH & prepare for installation
Required materials
Important! The remote radio head (RRH) must be 3BK28932AA Carrying handle (optional) 1
handled with care during unpacking and staging. 300780434 Eyebolt, lifting M10 (optional) 2
Note:
1. Depends on optical connection type. Only use SFPs ordered from Nokia.
Carrying handle
Top view
Solar shield
3 Install M10
eyebolts. Both
eyebolts must Hoisting points
be used when
M6 screws lifting RRH.
(4 total)
M10 M10
Important! The handle is for hand-carrying eyebolt
Note: When hoisting eyebolt
only. Do not use for hoisting! is complete, install
protective plugs (provided with RRH).
2 Carefully lift RRH out of box.
Bottom view
Protective packaging 4 Insert fiber optic
should remain on SFP into CPRI1 port
RRH during manual (and if required
transport CPRI2 port) before
hoisting and
Note: When manual reinstall protective
transportation is complete, cap.
CPRI2
the carrying handle may
be removed at the
customer’s discretion.
M6 torque: 5.6 N·m (4.1 lbf-ft); M10 torque: 34 N·m (25 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 5 of 18
2: Identify CLEI code and need for external ferrite
Required materials
Important! B25 RRH4x30s part number 3JR53349AA with CLEI code CRMRY00DRA require an 3JR53349AA B25 RRH4x30 1
1 Determine the CLEI code for the B25 RRH4x30 using one of the following methods:
Product label
2 Go to Step 2 in procedure
CLEI label
11: Connect DC power
cable and note whether an
external ferrite is required.
CLEI code
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 6 of 18
Safety statements for installation procedures
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.
DANGER
Electric shock hazard
Working in severe weather can result in personal injury or death and damage to the equipment.
Never install or perform maintenance during severe weather (high winds, lightning, blizzards, hurricane etc.).
WARNING
Falling-object hazard
If the B25 RRH4x30 falls while being lifted, it can result in personal injury or death and damage to the equipment.
Keep the area beneath the B25 RRH4x30 and the immediate surrounding area completely clear of personnel,
equipment, vehicles, etc. at all times during the lifting and moving operation.
WARNING
Overhead-load hazard
Hoisting points and apparatus can break, severely damaging the B25 RRH4x30 when it is being lifted to its final
mounting position.
Ensure that all hoisting points and lifting apparatus are defect free and properly attached before lifting the
B25 RRH4x30.
WARNING
Fall hazard
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof, etc.) follow safe work practices and wear
appropriate fall protection equipment.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 7 of 18
Safety statements for installation procedures (continued)
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.
CAUTION
Lifting hazard
Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.
Always use at least two people or a lifting device to move or position this equipment.
CAUTION
Laceration hazard
The mounting bracket components may have sharp edges and burrs and contact may cause cuts and lacerations.
Beware of sharp edges and burrs, especially when manually transporting or hoisting the B25 RRH4x30.
Wear appropriate personal protective equipment.
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in personal injury.
The B25 RRH4x30s are designed and installed in order that they are compliant with the exposure guidelines laid down
by 47 CFR 1.1307 to 1.1310.
For all staff that are required to work in close proximity to the equipment, for example maintenance personnel, contact
with the antenna should be avoided. No such persons shall stay in front of the operating product’s antenna at a
distance of less than 2.5 m and 0.6 m on each side of the antenna.
No other persons shall stay in front of the operating product’s antenna at a distance of less than 8.5 m and 3 m on each
side of the antenna.
Workers equipped with personal medical electronic devices, such as pacemakers and hearing aids, shall consult the
manufacturer's instructions and consult their occupational health practitioner.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 8 of 18
3: Install RRH on a wall
Required materials
1 Install pole bracket on wall using steel expansion 3JR53491AA Wall mounting bracket 1
plug and M12 screws, plain, and lock washers. 3JR58716AA Wall mounting kit 1
Lock Plain
washer washer
3 Install RRH on wall mounting bracket using M8
screws.
Pole
M12 bracket
Loosened
screws M8 mounting screw
Wall
mounting
RRH bracket on
wall
2 Use M8 screws to attach wall mounting bracket to
pole bracket.
Tabs overlap
top edge of
pole bracket
M8 screws
(2 per side)
1 Attach wall mounting bracket to Unistrut framing 3JR53491AA Wall mounting bracket 1
using M10 spring nuts, bolts, and plain washers. N/A Unistrut hardware, customer provided 1
Loosened
M8 mounting screw
Unistrut
M10
framing
bolts
RRH
Wall
mounting
bracket on
Unistrut
framing
Wall
mounting Important! 51 mm
bracket on (2 in) minimum
Unistrut rear clearance
framing required for wall
mounting bracket!
Note: The small pole mounting kit (3JR58710AA) is for 3JR53491AA Wall mounting bracket 1
“standard” type poles, 50 mm to 152 mm diameter. 3JR58710AA Small pole mounting kit 1
RRH
Loosened
M8 mounting
screw
M12 bolt
hardware
M8
screws
2 Use M8 screws
to attach wall
mounting bracket
to pole bracket.
M8 torque: 23 N·m (17 lbf-ft)
M12 torque: 50 N·m (37 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 11 of 18
6: Install RRH on a large pole
Required materials
Note: The large pole mounting kit (3JR58711AA) is for 3JR53491AA Wall mounting bracket 1
“utility” type poles, 152 mm to 380 mm diameter. 3JR58711AA Large pole mounting kit 1
RRH
Loosened
M8 mounting
screw
M8
screws
2 Use M8
screws to attach
wall mounting
bracket to pole
bracket.
M8 torque: 23 N·m (17 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 12 of 18
7: Connect protective earth (PE) ground
Required materials
1 Crimp 35 mm2 (#2 AWG) two-hole lug (from the 301022679 Ground lug kit (kit WES bag) 1
Bottom view
Front side
Connect to
ground system
Solar
shield
Wall or M6 ground
pole side points
1AB428730002
Note: Connect TxRx3 and TxRx4 (when applicable) 7/16 DIN 10 W load terminator (See note 2) 2 or 0
before TxRx1 and TxRx2. 300275484 Weatherproofing kit for RF cable connectors (optional) 1
Notes:
Bottom view Front side
1. Depends on length and connector type
2. Required for unused RF ports
Supported RF configurations
Configuration Antenna connections Load terminators
2T2R TxRx1, TxRx2 TxRx3, TxRx4
2T4R, 4T4R TxRx1, TxRx2, TxRx3, TxRx4 —
TxRx1
TxRx3
TxRx4
TxRx2
1 Attach 7/16 DIN connector to each RF cable.
Bottom view Front side 1AB031180001 R2CT plug extension accessory (optional) 1 or 2
Notes:
1. Depends on optical connection type. Only use SFPs ordered from Nokia.
2. Depends on length and optical connection type. If 2 fibers are connected to the RRH,
they must be the same length (with a tolerance of +/- 100 m).
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser
radiation can cause considerable injuries to the eyes.
CPRI1
CPRI2
4 OR User_ALM_2_RTN BL = Blue
6 BR User_ALM_4_RTN GR = Green
AISG
8 BL User_ALM_1_RTN WH = White
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 16 of 18
11: Connect DC power cable
Required materials
turn-on before completing this procedure. 1. Depends on power cable outside diameter (OD)
2. Required if RRH CLEI code = CRMRY00DRA
See LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-
01725-0002-RJZZA, available at http://support.alcatel-lucent.com/.
Bottom view Front side Important! B25 RRH4x30s with CLEI code CRMRY00DRA
require an external ferrite on the DC power cable.
If the B25 RRH4x30 CLEI code is not CRMRY00DRA, then
the external ferrite is not required.
Ferrite APN1 Outside Inside Dimension A2
diameter (OD) diameter (ID) (maximum)
1AB093970037 38.60 mm 18.35 mm 0
1AB093970027 56.40 mm 25.65 mm 50 mm (1.97 in)
-48 VDC
Notes:
1. Ferrite required depends on the OD of the DC power cable
2. Once installed, the ferrite must be secured in close proximity
1 Attach DC power plug to power 3 Plug DC (as defined in the table) to the DC power plug on the power
cable (instructions provided power cable cable
with plug). into RRH.
Off LED disabled or no power supplied LED is disabled in software or no DC power to RRH
Solid red Initial power on RRH is initializing (if just powered on or reset)
Non-recoverable critical failure A critical hardware failure prevents the transmit and/or active receive paths from functioning
Non-critical non-recoverable failure Non-critical fault (other than antenna) detected, fault is not recoverable, RF transmission is still ON
Flashing red Recoverable critical failure RRH not currently operational due to hardware fault, but should recover (e.g., under-temperature
warm up, over-temperature critical shutdown)
External power supply failure A recoverable fault is detected and the external connections (power, antenna) should be checked
Non-critical recoverable failure Non-critical fault (other than antenna) detected, fault is recoverable, RF transmission is still ON
Flashing yellow Software download RRH is downloading software and RF transmission is OFF, but is currently operational
Solid yellow Slave CPRI link failure The slave CPRI link (CPRI1) has failed
Flashing green Standby No critical failures or faults, but the transmitter is disabled
Bottom view
Status LED
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 18 of 18