B25 RRH4x30 Field Installation Guide

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

B25 RRH4x30 (UHFA) Field Installation Guide

3MN-02023-0004-RJZZA (3JR63007AAAD), Issue 4, January 2017

Product photo Physical attributes

538.5 mm
(21.2 in)

304 mm
182.4 mm
(11.97 in)
(7.18 in)
External interfaces Weight = 24 kg
(bottom of RRH) (52.9 lbs)
Important!
The Nokia B25 RRH4x30 must be installed vertically oriented with all cabling Notes:
interfaces at the bottom. Upside down and horizontal mounting are not allowed. 1. All specifications are with the solar shield installed.
The B25 RRH4x30 may also be referred to as UHFA. 2. Dimensions do not include connectors or other small protrusions.
Intended audience
This document is intended for field construction personnel during the installation of hardware for Nokia customers. This product must only be installed
by a Qualified Person (a person designated by the employer; and by reason of training, experience, or instruction has demonstrated the ability to
perform safely all assigned duties; and, when required is properly licensed in accordance with federal, state, or local laws and regulations). Proper safety
polices and practices must be adhered to. Risks are discussed in more detail in the LTE B25 RRH4x30 – Site Preparation Guidelines (3MN-02023-0001-
RJZZA) and LTE Remote Radio Head (RRH) - Safety Guidelines (3MN-01725-0002-RJZZA) documents available to Nokia customers at
http://support.alcatel-lucent.com/. No other use of this document is approved.
Legal notice
Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners.
The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein.
© 2017 Nokia.
Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone
outside Nokia without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Required parts
Part No. 3JR53349AA, 3JR53349AB Part No. 3JR58716AA

Description B25 RRH4x30 Description Wall mounting kit

Qty. 1 Qty. 1

Comments Includes RRH with solar shield Comments Optional: Required only for wall
mounting

Part No. 3JR53491AA Part No. Part number depends on pole


Small pole Large pole
size

Description Wall mounting bracket Description Pole mounting kit

Qty. 1 Qty. 1

Comments Required for wall and pole Comments Optional: Required only for pole
mounting mounting

Part No. 3BK28932AA Part No. 1AB435070001

Description Carrying handle Description DC power plug, circular, 2-pin

Qty. 1 Qty. 1

Comments 1 required per RRH, can be Comments 1 required per RRH, used with
reused customer-provided power cable

Part No. 3JR58776AA Part No. Part number depends on power


cable outside diameter (OD)

Description Spare solar shield kit Description Ferrite core, snap-on, round

Qty. 1 Qty. 1

Comments Optional: Required for Comments 1 required per RRH with CLEI
replacement of damaged solar code CRMRY00DRA. If CLEI
shield; includes fasteners code is not CRMRY00DRA,
then ferrite is not required.

Part No. 300780434 Part No. 301080628

Description Eyebolt, lifting M10 Description RRH outdoor grounding kit 2


Includes 25 ft. of 35 mm (2
Qty. 2 Qty. 1 AWG) ground wire, C-tap, and
hardware
Comments Optional: Customer-provided Comments Required for protective earth
equivalent allowed (PE) ground

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 2 of 18
Required parts (continued)
Part No. 301022679 Part No. Part number depends on length
required and connector type
Includes 2 AWG and 6 AWG 2-
Description Ground lug kit (kit WES bag) hole lugs; M6 bolts, plain, and Description RF cable, coax, 7/16 DIN male Includes coaxial cable with 7/16
Qty. 1 lock washers; and Torx security Qty. 2 or 4 DIN male connectors
bit
Comments Required for PE ground Comments 1 required for each antenna
connection used

Part No. Part number depends on type: Part No. 1AB428730002


MMDF or SMDF

Description SFP transceiver, Rate 3 to 7, LC Description 7/16 DIN 10 W load terminator


connector
Qty. 1 or 2 Qty. 2 or 0 (optional)
Comments 1 required per CPRI connection Comments Required for unused RF ports

Part No. Part number depends on length Part No. 300275484


and type: MMDF or SMDF

Description Optical fiber, LC-LC connectors Description Weatherproofing kit for RF cable
connectors and ferrite
Qty. 1 or 2 Qty. 1
Comments 1 required per CPRI connection, Comments Required for ferrite, optional for
must be same length +/- 100 m RF cable connectors

Part No. 1AB027220001 Part No. Part number depends on length

Description R2CT weatherized plug Description User alarm cable, 4 pair, circular
DIN male on one end
Qty. 1 or 2 Qty. 1 (optional)
Comments 1 required per CPRI connection Comments Required for user alarms

Part No. 1AB031180001 Part No. Part number depends on length

Description R2CT plug extension accessory Description AISG cable, 8-pin circular DIN
Qty. 1 or 2 (optional) Qty. 1 (optional)
Comments 1 required per R2CT plug when Comments Required for AISG daisy chain
simplex optical fiber fan out is connection
between 100 mm and 500 mm

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 3 of 18
External interfaces
Bottom view

CPRI1 CPRI2 ALARM AISG Status GND -48


LED VDC

Solar shield

Important!
Connect CPRI1
port to LTE
BBU

Rx1MON TxRx1 TxRx3 TxRx4 TxRx2

Tx1Mon Rx3Mon Tx3Mon Rx4Mon Tx4Mon Rx2Mon Tx2Mon

Note: Wall mounting bracket not shown in this view

Attention: For all product-specific figures in this document, the colors depicted are for identification purposes only. Final product colors may be different.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 4 of 18
1: Unpack RRH & prepare for installation
Required materials

Part No. Description Qty.

3JR53349AA, 3JR53349AB B25 RRH4x30 1

Important! The remote radio head (RRH) must be 3BK28932AA Carrying handle (optional) 1

handled with care during unpacking and staging. 300780434 Eyebolt, lifting M10 (optional) 2

See note 1 SFP transceiver, MMDF or SMDF, CPRI Rate 3 to 7, 1 or 2

1 Attach carrying handle to RRH using M6 screws. LC connector

Note:
1. Depends on optical connection type. Only use SFPs ordered from Nokia.
Carrying handle
Top view
Solar shield
3 Install M10
eyebolts. Both
eyebolts must Hoisting points
be used when
M6 screws lifting RRH.
(4 total)

M10 M10
Important! The handle is for hand-carrying eyebolt
Note: When hoisting eyebolt
only. Do not use for hoisting! is complete, install
protective plugs (provided with RRH).
2 Carefully lift RRH out of box.
Bottom view
Protective packaging 4 Insert fiber optic
should remain on SFP into CPRI1 port
RRH during manual (and if required
transport CPRI2 port) before
hoisting and
Note: When manual reinstall protective
transportation is complete, cap.

CPRI2
the carrying handle may
be removed at the
customer’s discretion.
M6 torque: 5.6 N·m (4.1 lbf-ft); M10 torque: 34 N·m (25 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 5 of 18
2: Identify CLEI code and need for external ferrite
Required materials

Part No. Description Qty.

Important! B25 RRH4x30s part number 3JR53349AA with CLEI code CRMRY00DRA require an 3JR53349AA B25 RRH4x30 1

external ferrite on the DC power cable. Note:


1. If the B25 RRH4x30 part
If the B25 RRH4x30 CLEI code is not CRMRY00DRA, then the external ferrite is not required. number is 3JR53349AB, the
external ferrite is not required.

1 Determine the CLEI code for the B25 RRH4x30 using one of the following methods:

RRH shipping box RRH right side view

Product packaging label

Product label

2 Go to Step 2 in procedure
CLEI label
11: Connect DC power
cable and note whether an
external ferrite is required.

CLEI code

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 6 of 18
Safety statements for installation procedures
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.

DANGER
Electric shock hazard
Working in severe weather can result in personal injury or death and damage to the equipment.
Never install or perform maintenance during severe weather (high winds, lightning, blizzards, hurricane etc.).

WARNING
Falling-object hazard
If the B25 RRH4x30 falls while being lifted, it can result in personal injury or death and damage to the equipment.
Keep the area beneath the B25 RRH4x30 and the immediate surrounding area completely clear of personnel,
equipment, vehicles, etc. at all times during the lifting and moving operation.

WARNING
Overhead-load hazard
Hoisting points and apparatus can break, severely damaging the B25 RRH4x30 when it is being lifted to its final
mounting position.
Ensure that all hoisting points and lifting apparatus are defect free and properly attached before lifting the
B25 RRH4x30.

WARNING
Fall hazard
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof, etc.) follow safe work practices and wear
appropriate fall protection equipment.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 7 of 18
Safety statements for installation procedures (continued)
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.

CAUTION
Lifting hazard
Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.
Always use at least two people or a lifting device to move or position this equipment.

CAUTION
Laceration hazard
The mounting bracket components may have sharp edges and burrs and contact may cause cuts and lacerations.
Beware of sharp edges and burrs, especially when manually transporting or hoisting the B25 RRH4x30.
Wear appropriate personal protective equipment.

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in personal injury.
The B25 RRH4x30s are designed and installed in order that they are compliant with the exposure guidelines laid down
by 47 CFR 1.1307 to 1.1310.
For all staff that are required to work in close proximity to the equipment, for example maintenance personnel, contact
with the antenna should be avoided. No such persons shall stay in front of the operating product’s antenna at a
distance of less than 2.5 m and 0.6 m on each side of the antenna.
No other persons shall stay in front of the operating product’s antenna at a distance of less than 8.5 m and 3 m on each
side of the antenna.
Workers equipped with personal medical electronic devices, such as pacemakers and hearing aids, shall consult the
manufacturer's instructions and consult their occupational health practitioner.

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 8 of 18
3: Install RRH on a wall
Required materials

Part No. Description Qty.

3JR53349AA, 3JR53349AB B25 RRH4x30 1

1 Install pole bracket on wall using steel expansion 3JR53491AA Wall mounting bracket 1

plug and M12 screws, plain, and lock washers. 3JR58716AA Wall mounting kit 1

Lock Plain
washer washer
3 Install RRH on wall mounting bracket using M8
screws.
Pole
M12 bracket
Loosened
screws M8 mounting screw

Wall
mounting
RRH bracket on
wall
2 Use M8 screws to attach wall mounting bracket to
pole bracket.

Wall Rear view of


mounting assembled
bracket mounting brackets

Tabs overlap
top edge of
pole bracket
M8 screws
(2 per side)

M8 torque: 23 N·m (17 lbf-ft)


M12 torque: 50 N·m (37 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 9 of 18
Required materials
4: Install RRH on Unistrut® framing Part No. Description Qty.

3JR53349AA, 3JR53349AB B25 RRH4x30 1

1 Attach wall mounting bracket to Unistrut framing 3JR53491AA Wall mounting bracket 1

using M10 spring nuts, bolts, and plain washers. N/A Unistrut hardware, customer provided 1

Wall mounting bracket


2 Install RRH on wall mounting bracket using M8
screws.

Loosened
M8 mounting screw
Unistrut
M10
framing
bolts
RRH
Wall
mounting
bracket on
Unistrut
framing

Wall
mounting Important! 51 mm
bracket on (2 in) minimum
Unistrut rear clearance
framing required for wall
mounting bracket!

M8 torque: 23 N·m (17 lbf-ft)


M10 torque: 34 N·m (25 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 10 of 18
5: Install RRH on a small pole
Required materials

Part No. Description Qty.

3JR53349AA, 3JR53349AB B25 RRH4x30 1

Note: The small pole mounting kit (3JR58710AA) is for 3JR53491AA Wall mounting bracket 1

“standard” type poles, 50 mm to 152 mm diameter. 3JR58710AA Small pole mounting kit 1

RRH

Wall mounting bracket

Loosened
M8 mounting
screw

1 Attach pole mounting


brackets to pole.

3 Install RRH on wall


mounting bracket
using M8 screws.

M12 bolt
hardware

M8
screws

2 Use M8 screws
to attach wall
mounting bracket
to pole bracket.
M8 torque: 23 N·m (17 lbf-ft)
M12 torque: 50 N·m (37 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 11 of 18
6: Install RRH on a large pole
Required materials

Part No. Description Qty.

3JR53349AA, 3JR53349AB B25 RRH4x30 1

Note: The large pole mounting kit (3JR58711AA) is for 3JR53491AA Wall mounting bracket 1

“utility” type poles, 152 mm to 380 mm diameter. 3JR58711AA Large pole mounting kit 1

RRH

Wall mounting bracket

Loosened
M8 mounting
screw

1 Attach pole mounting


bracket to pole.
3 Install RRH on wall
mounting bracket
using M8 screws.
Band clamps

M8
screws

2 Use M8
screws to attach
wall mounting
bracket to pole
bracket.
M8 torque: 23 N·m (17 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 12 of 18
7: Connect protective earth (PE) ground
Required materials

Part No. Description Qty.

301080628 RRH outdoor grounding kit 1

1 Crimp 35 mm2 (#2 AWG) two-hole lug (from the 301022679 Ground lug kit (kit WES bag) 1

ground lug kit) onto end of ground cable. Clean


the contact surface area and use antioxidant to
prevent oxidation.

2 Connect ground lug to RRH using M6 bolts, plain,


and lock washers.

Bottom view
Front side
Connect to
ground system

Solar
shield

Wall or M6 ground
pole side points

M6 torque: 5.6 N·m (4.1 lbf-ft)


B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 13 of 18
8: Connect RF cables
Required materials

Part No. Description Qty.

See note 1 RF cable, coax, 7/16 DIN male 2 or 4

1AB428730002
Note: Connect TxRx3 and TxRx4 (when applicable) 7/16 DIN 10 W load terminator (See note 2) 2 or 0

before TxRx1 and TxRx2. 300275484 Weatherproofing kit for RF cable connectors (optional) 1

Notes:
Bottom view Front side
1. Depends on length and connector type
2. Required for unused RF ports

Supported RF configurations
Configuration Antenna connections Load terminators
2T2R TxRx1, TxRx2 TxRx3, TxRx4
2T4R, 4T4R TxRx1, TxRx2, TxRx3, TxRx4 —
TxRx1

TxRx3

TxRx4

TxRx2
1 Attach 7/16 DIN connector to each RF cable.

2 Connect RF cables to RF ports.


Note: The TxRx1 and TxRx2 ports each include an
integrated (internal) bias tee.
OR
RF
3 Apply weatherproofing according to local convention.
cable RF load
terminator
4 Install 7/16 DIN 10 W load terminator on each unused
RF port.

7/16 DIN connector torque: 25 N·m (18.4 lbf-ft)


7/16 DIN 10 W load terminator torque: 20 N·m (14.8 lbf-ft)
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 14 of 18
9: Connect optical fiber cable
Required materials

Part No. Description Qty.


Note: The bend radius limit for fiber optic cable is See note 1 SFP transceiver, MMDF or SMDF, CPRI Rate 3 to 7, LC connector 1 or 2
82.5 mm (3.25 inches). This bend radius limit must not
See note 2 Optical fiber, MMDF or SMDF, LC-LC connectors 1 or 2
be exceeded when installing the fiber optic cables.
1AB027220001 R2CT weatherized plug 1 or 2

Bottom view Front side 1AB031180001 R2CT plug extension accessory (optional) 1 or 2

Notes:
1. Depends on optical connection type. Only use SFPs ordered from Nokia.
2. Depends on length and optical connection type. If 2 fibers are connected to the RRH,
they must be the same length (with a tolerance of +/- 100 m).

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser
radiation can cause considerable injuries to the eyes.
CPRI1

CPRI2

Never look into the end of an exposed fiber or into an open


optical connector when the optical source is switched on.
Always observe the laser warning instructions.
1 If necessary, insert SFP into
CPRI1 port and lock into place.
NOTICE
Protect fiber cable
Note: Clean and inspect the LC
connectors on the CPRI fiber optic Mishandling fiber optic cable can result in damaged and non-
cable before connecting to SFP. functioning cables.
The optical cable is very sensitive, take the maximum
R2CT coupling nut precaution when installing it. The optical fiber should be
protected in solid pipe. Do not use cable ties on the fiber
2 Use assembly instructions provided with R2CT cable. Do not cut this cable on site, excess length should be
weatherized plug to assemble R2CT plug onto coiled inside the eNodeB. The fiber optic connector should be
optical fiber and connect to CPRI1 port. protected by a cap when not being used. Respect the bending
radius during the manipulation of optical cable (82.5 mm).
3 If necessary, repeat Steps 1 and 2 to connect
See LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
a second optical fiber to CPRI2 port. 0002-RJZZA, available at http://support.alcatel-lucent.com/.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 15 of 18
10: Connect user alarm & AISG cables
Required materials

Part No. Description Qty.


(optional) Depends on length User alarm cable, 4 pair, circular DIN male on one end 1

Depends on length AISG connection cable, 8-pin circular DIN 1

Bottom view Alarm connector pin assignments


Front side
Pin Wire ALARM port
color designation
Alarm & AISG 1 WH/BR User_ALM_4_P
connector pin
2 GR User_ALM_3_RTN
configuration
3 WH/BL User_ALM_1_P Legend:

4 OR User_ALM_2_RTN BL = Blue

5 WH/OR User_ALM_2_P BR = Brown

6 BR User_ALM_4_RTN GR = Green

7 WH/GR User_ALM_3_P OR - Orange


ALARM

AISG

8 BL User_ALM_1_RTN WH = White

2 Connect alarm 3 Connect AISG cable


cable to RRH to RRH AISG port.
ALARM port. AISG connector pin assignments
Note: AISG output Pin Designation
port has female pins.
1 N/C
2 N/C

1 Connect alarm cable 3 RS485 B


to distribution frame. 4 Connect AISG cable to 4 N/C
AISG input port of another 5 RS485 A
antenna line device (ALD).
6 +10 V to +30 V DC output
7 DC return
8 N/C

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 16 of 18
11: Connect DC power cable
Required materials

Part No. Description Qty.


DANGER 1AB435070001 DC power plug, circular, 2-pin 1

Electric shock hazard N/A Power cable, customer provided 1

See notes 1 & 2 Ferrite core, snap-on, round (optional) 1


Contact with energized network element power supply
lines can result in serious personal injury. 300275484 Weatherproofing kit (tape) - See note 2 1

Ensure that the DC power is OFF and secured against Notes:

turn-on before completing this procedure. 1. Depends on power cable outside diameter (OD)
2. Required if RRH CLEI code = CRMRY00DRA
See LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-
01725-0002-RJZZA, available at http://support.alcatel-lucent.com/.
Bottom view Front side Important! B25 RRH4x30s with CLEI code CRMRY00DRA
require an external ferrite on the DC power cable.
If the B25 RRH4x30 CLEI code is not CRMRY00DRA, then
the external ferrite is not required.
Ferrite APN1 Outside Inside Dimension A2
diameter (OD) diameter (ID) (maximum)
1AB093970037 38.60 mm 18.35 mm 0
1AB093970027 56.40 mm 25.65 mm 50 mm (1.97 in)
-48 VDC

Notes:
1. Ferrite required depends on the OD of the DC power cable
2. Once installed, the ferrite must be secured in close proximity
1 Attach DC power plug to power 3 Plug DC (as defined in the table) to the DC power plug on the power
cable (instructions provided power cable cable
with plug). into RRH.

A Important! The ferrite must be secured to the power


Rear view of
DC power cable as follows: DIM “A” for 1AB093970037 = 0
plug body A = -48V DIM “A” for 1AB093970027 ≤ 50 mm
B = 0V
Ferrite 2 If required,
attach ferrite to Note: B25 RRH4x30s part number 3JR53349AB
power cable. do not require an external ferrite.
To -48 VDC Important! Ferrite must be wrapped with weatherproofing
tape to provide UV protection and a watertight seal.
B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 17 of 18
General status LED states

General status LED states after power up


LED state Status Description

Off LED disabled or no power supplied LED is disabled in software or no DC power to RRH

Solid red Initial power on RRH is initializing (if just powered on or reset)

Non-recoverable critical failure A critical hardware failure prevents the transmit and/or active receive paths from functioning

Non-critical non-recoverable failure Non-critical fault (other than antenna) detected, fault is not recoverable, RF transmission is still ON

Flashing red Recoverable critical failure RRH not currently operational due to hardware fault, but should recover (e.g., under-temperature
warm up, over-temperature critical shutdown)

External power supply failure A recoverable fault is detected and the external connections (power, antenna) should be checked
Non-critical recoverable failure Non-critical fault (other than antenna) detected, fault is recoverable, RF transmission is still ON

External antenna failure An equipped antenna has a VSWR fault

Flashing yellow Software download RRH is downloading software and RF transmission is OFF, but is currently operational

Solid yellow Slave CPRI link failure The slave CPRI link (CPRI1) has failed

Solid green Normal operation No critical failures or faults, transmitter is enabled.

Flashing green Standby No critical failures or faults, but the transmitter is disabled

Bottom view

Status LED

B25 RRH4x30 (UHFA) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-02023-0004-RJZZA Issue 4 January 2017 Page 18 of 18

You might also like