Catálogo de Fusibles: Líder en Suministros de Productos Eléctricos

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 54

Líder en suministros de productos Eléctricos

CATÁLOGO DE FUSIBLES

N T0 0C
N H00 C
gL/g G

8 0A c

500 V~1 20kA


690V ~ 50kA
IEC269
DIN 43620
General technical date

Name NH/NT NGT/RS0 Cylindrical D0 Screw Switch

Standards

Dimensions

Operating classes

Rated voltage

Rated current range

Rated breaking
capacity

Mounting position

Resistance to
climate
rel.humidity

Non-
interchangea-
bility

Application

For more information visit our website at www.kep.cl


NH(NT) Series Fuse

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


NH Fuse link
Features

In

NT 00C
NH 00C
gL/g G

80 A
500V ~120
kA
690V ~50k
A
IEC269
DIN 43620

NT0 0
NH0 0
gL/gG

16 0A
500V ~120k A
690V ~50kA
IEC269
DIN 43620

For more information visit our website at www.kep.cl


NH Fuse link (Continuation)

In

NT0
NH0
gL/gG

16 0A
500V~120kA
690V~ 50kA
IEC269
DIN 43620

NT1
NH1
gL/gG

25 0A
500V ~120k
A
690V ~50kA
IEC269
DIN 43620

NT2
NH2
gL/gG

400 A
500V~12 0kA
690V~50 kA
IEC269
DIN 43620

NT3
NH3
gL/gG

630 A
500V~1 20kA
690V~5 0kA
IEC269
DIN 43620

NT4
NH4
gL/gG

125 0A
500V~12 0kA
690V~50 kA
IEC269
DIN 43620

For more information visit our website at www.kep.cl


NH-FUSES

NH-Fuse bases

160A/Rated current 160A


single-pole
c

A
0 62
0

00 16 43
H 0V DIN
N /69 9
500 26
IEC

triple-pole

single-pole

Rated current 250A


single-pole

400A/Rated current 400A


single-pole
NH 2
c

Sis t
500/6
90V
401
IEC2 400
69
DIN4 A
3620

Rated current 630A


/single-pole
NH 3 c

Sis
500/
690V
t 601
IEC
269 630
DIN A
436
20

Rated current 1250A


single-pole
NH
50 4 Si c
0/6 st
90
12 10 01
IE V
C2
69
DI 50
N4
36
A
20

1000V/Rated insulation Voltage1000V

For more information visit our website at www.kep.cl


DIMENSION DRAWING

NH ( NT ) fuse link
Dimension drawing
0
10 -0.3
0
10 -0.3

A A
A
0
10 -0.3

B B B

E
E
C
F
C C
D
F F
D D

No.

NH fuse base
Dimension drawing
C

H
C
C

2- D G G
B 2- D 2- D G
B
A A B
A
F
F

F
E

No.

For more information visit our website at www.kep.cl


DIMENSION DRAWING

NH fuse base

Dimension drawing

154

65
48
64

95
Characteristic curves

For more information visit our website at www.kep.cl


CHARACTERISTIC CURVES

Characteristic curves

For more information visit our website at www.kep.cl


Fuse Disconnecting Switches

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


FUSE DISCONNECTING SWITCHES

NH fuse disconnecting switches

Features

In

A
NH-fuse disconnecting switches 3 phases break simultaneously,upper/lower end connection.

NH-fuse disconnecting switches single-phase breaking simultaneously,upper/lower end connection.

For more information visit our website at www.kep.cl


DIMENSION DRAWING

Dimension drawing

For more information visit our website at www.kep.cl


FUSE DISCONNECTING SWITCHES

NH fuse disconnecting switches


Features

In

A
For install in switchboard, STAB/SIKUS-switchboard and 8HP-case

Dimension drawing

For more information visit our website at www.kep.cl


Solar Fuse

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


Solar Fuse

Rated breaking capacity: C kA

In

gPV

10

Rated current 20A

ZT18- 32
1000V dc 20A
IEC 269 10x38

ZT18- 32X
c
Rated current 20A
1000V dc 20A
IEC 269 10x38

with LED
80

10.3
60

38.5

78
78
18

For more information visit our website at www.kep.cl


Technical Ratings

Current Energy Integrals Power Loss


Order rating (A2s/l2t) (Watts)
No. (Amps)

01PV1038
02PV1038
03PV1038
3.5PV1038
04PV1038
05PV1038
06PV1038
08PV1038
10PV1038
12PV1038
15PV1038
20PV1038

Characteristic curves

20PV1038

15PV1038

12PV1038

10PV1038

08PV1038

06PV1038

05PV1038

04PV1038

3.5PV1038
time (S)

03PV1038

02PV1038

01PV1038

Perspective current DC-time constant 1ms(Amp)

For more information visit our website at www.kep.cl


Cylindrical Contact Cap Fuses

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


CYLINDRICAL CONTACT CAP FUSES

Cylindrical fuse links

In

I 8.5 X 31.5
500V~100kA
gL 2 A
IEC269
VDE0636

I 10 X 38
500V~100kA
gL 2 A
IEC269
VDE0636

I 14 X 51
500V~100kA
gL 40 A
IEC269
VDE0636

I 22 X 58
500V~100kA
gL 80 A
IEC269
VDE0636

For more information visit our website at www.kep.cl


CYLINDRICAL CONTACT CAP FUSES

Mounting fuse bases for cylindrical fuse links

Rated current 32A

RT18-32
10 X 38
32A 690 V
IEC 269

VDE 0636

Rated current 32A

c
c
c
RT18-32X
RT18-32X
RT18-32X

10 X 38
10 X 38
32A 10 X 38
690 V 32A 690 V
IEC 269 32A 690 V
IEC 269
VDE 0636 IEC 269
VDE 0636
VDE 0636

Rated current 63A


c

RT18-63
14 X 51
63A 690 V
IEC 269

VDE 0636

Rated current 63A


c
c
c
RT18-63X
RT18-63X
RT18-63X

14 X 51

with LED
14 X 51
14 X 51
63A 690 V 63A 690 V 63A
IEC 269 690 V
IEC 269
IEC 269
VDE 0636
VDE 0636
VDE 0636

Rated current 125A


c

RT18-125
22 X 58
63A 690 V
IEC 269

VDE 0636

Rated current 125A


c

with LED
c
c
RT18-125X
RT18-125X
RT18-125X

22 X 58
22 X 58
63A 22 X 58
690 V 63A 690 V
IEC 269 63A 690 V
IEC 269
VDE 0636 IEC 269
VDE 0636
VDE 0636

For more information visit our website at www.kep.cl For more information visit our website at www.zhotr.com
CYLINDRICAL CONTACT CAP FUSES

Mounting fuse bases for cylindrical fuse links

Rated current 32A

ZT18- 32
690V ac 32A
IEC 269 10x38

ZT18- 32X
690V ac 32A

Rated current 32A


IEC 269 10x38

with LED

Rated current 63A

ZT18 -63
690V ac 63A
IEC 269 14x51

c
Rated current 63A
ZT18- 63X
690V ac 63A
IEC 269 14x51

with LED

Rated current 125A

ZT18-1 25
690V ac 125A
IEC 269 22x58

Rated current 125A


c

ZT18 -125X
690V ac 125A
IEC 269 22x58

with LED

For more information visit our website at www.zhotr.com For more information visit our website at www.kep.cl
DIMENSION DRAWING

Cylindrical fuse link


Dimension drawing

A
C C B

Mounting fuse bases for cylindrical fuse links


Dimension drawing

Dimension drawing
E
D

E
D

A
B
TH35(Guide installation)
A
B
C
C
K
L

C
C

For more information visit our website at www.kep.cl


CHARACTERISTIC CURVES

Characteristic curves

For more information visit our website at www.kep.cl


Screw Type Fuse

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


SCREW TYPE FUSES
D0- Fuse links

In

D0- Flush mounting fuse bases D01/D02/D03, single-pole

In

with protective cover, with snap-on fitting

without protective cover, with snap-on fitting

D0- Flush mounting fuse bases D01/D02, triple-pole


with protective cover, with snap-on fitting

For more information visit our website at www.kep.cl


SCREW TYPE FUSES

DI DII DIII Fuse links

Features

In

A
Fuse links TN DZ/NDZ/E16

Characteristic: slow

Characteristic: quick

Fuse links TDz (slow)

Packed in 5 packs of 5

Packed of 10

For more information visit our website at www.kep.cl


SCREW TYPE FUSES

Screw type fuse base

In

Rated current 25A

Rated current 25A

Rated current 63A

Rated current 25A

Rated current 63A

Rated current 25A

Rated current 63A

For more information visit our website at www.kep.cl


DIMENSION DRAWING

Screw type fuses


Dimension drawing

D
C
A

L
D
C
B
A

Screw type fuses

Dimension drawing

4.2 5.8 8 17
max.49

max. 32
33

34
73

34

25
48

SS-2256

4.2 19
max.29
max.44.6
27 48
max.75
67

For more information visit our website at www.kep.cl


DIMENSION DRAWING

Dimension drawing

4.5 1.5 1.8 1.5 1.8


4.5
31

max. 41.5

37
30

max. 41.5
34

34

14

34
29

40
SS-2260
27 9
max.38 18.5

SS-2263
45 34 9
max.83 max.46 45
max.83

38
42
)

25

77
72

TH35(

2-5x7

37
79
82 62 90
48

48
95

2-6x10

37
110 80

For more information visit our website at www.kep.cl


NGT,RSO&RS3 Series Fuse Links

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


NGT-FUSE LINKS

NGT-fuse links

In

A
With bolt-on lugs
Rated voltage: AC 690V

NGT 00
aR

16 0A
500V~ 120kA
690V~ 50kA
IEC269
DIN 43620

With bolt-on lugs


c

NG T1
aR
25 0A
500 V~1
20k A
Rated voltage: AC 690V
690 V~5
0kA
IEC269
DIN 4362
0

With bolt-on lugs


Rated voltage: AC 690V
c

NG T2
aR
40 0A
500V ~120
kA
690V ~50k
A
IEC269
DIN 4362
0

With bolt-on lugs


Rated voltage: AC 690V
c

NG T3
aR
63 0A
500V ~120
kA
690V ~50k
A
IEC269
DIN 43620

For more information visit our website at www.kep.cl


NGT-FUSE LINKS
RS0-FUSE LINKS

RS0-fuse links

In

A
With bolt-on lugs
Rated voltage: AC 690V

Ke p c
RS0-5 0
aR

50A
500V~120kA
690V~50kA
IEC269
DIN 43620

With bolt-on lugs


Ke p c Rated voltage: AC 690V
RS0 -10 0
aR

10 0A
500V~120k
A
690V~50kA
IEC269
DIN 43620

With bolt-on lugs


Rated voltage: AC 690V

Ke p c
RS0 -200
aR

200 A
500V~120kA
690V~50kA
IEC269
DIN 43620

Ke p c
RS0- 350
aR

350 A
500V~12 0kA
690V~50 kA
IEC269
DIN 43620

With bolt-on lugs


Rated voltage: AC 690V

Ke p c
RS0 -480
aR

480 A
500V~ 120kA
690V~ 50kA
IEC269
DIN 43620

For more information visit our website at www.kep.cl


DIMENSION DRAWING

NGT fuse
Dimension drawing

G
F
G

E
D
E

C
C B 6
B A E
A

RS0(RS3) fuse
Dimension drawing
F
G

2-MxN
D
E

C
B
A

For more information visit our website at www.kep.cl


Bolting Type Fuses

Low Voltage Series Fuse

For more information visit our website at www.kep.cl


BOLTING TYPE FUSES

Bolting type fuses

In

For more information visit our website at www.kep.cl


BOLTING TYPE FUSES

Bolting type fuses

In

For more information visit our website at www.kep.cl


BOLTING TYPE FUSES

Bolting type fuses

In Order No.

For more information visit our website at www.kep.cl


BOLTING TYPE SERIES FUSE

Dimension drawing

A
B
H
C
D I
G
E

K
J L

For more information visit our website at www.kep.cl


H.V Current-limiting Series Fuses

37 For more
For moreinformation
information visit
visitour
our website
websiteatat wwww.kep.cl
ww.kep.cl
H.V CURRENT-LIMITING FUSES

For more information visit our website at www.kep.cl 38


H.V CURRENT-LIMITING FUSES

Selection of prodper fuse links for transformer protection

Dimension drawing
D

p
Ke

Kep
c
Kep c
Kep
c

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

H.V.HRC current-limiting fuses type A/B for transformer protection

Mode and implication

- X R N T 1 - -

Basic Data

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

A/BSelection of prodper H.V.fuse according to the transformer capacity

Dimension drawing

p
e
K

p
e
K

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

H.V.HRC.current-limiting fuses type W for motor protection

Mode and implication

X R N M 1-

Basic Data

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES
Dimension drawing

p
e
K

p
e
K

Kep

Kep
c

c
c

p
p

e
e

K
K

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

Characteristic curves

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES
Characteristic curves

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

H.V HRC current-limiting fuses type F for transformer protection

Mode and implication

F A-
nsert installation

Dimension drawing
c

p
Ke

Kep
c
Kep
c

Kep
c

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

Dimension drawing

I 2t Characteristics of Full-range H.V. Current-limiting Fuses Type F

Selection of Proper Full-rage H.V. Fuses Type F for Transformer Protection

Characteristic curves

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

H.V HRC current-liniting Fuses type XRNP for transformer protection

Mode and implication

Dimension drawing
c
Kep

Kep
c
Kep
c
Kep

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

Dimension drawing

p
Ke

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

H.V HRC current-liniting Fuses type XRNP for transformer protection

Mode and implication

Basic Date

Dimension drawing

c
Kep

For more information visit our website at www.kep.cl


H.V CURRENT-LIMITING FUSES

Dimension drawing

p
e
K

For more information visit our website at www.kep.cl


HIGH VOLTAGE DROP-OUT FUSES

High voltage drop-out fuses

In

A Fix Fix

Fix

For more information visit our website at www.kep.cl


LÍDER EN SUMINISTROS DE PRODUCTOS ELÉCTRICOS

CONTACTO
Dirección de Nuestras Oficina y Bodega
Marathon 1315 BODEGA C-01
ÑUÑOA, SANTIAGO-CHILE
www.kep.cl
contacto@kep.cl
(56) 2 29638330

You might also like