HMTS SERIES

The World’s First 2nd Generation


Low Temperature Plasma Sterilizer

HMTS-80E

HMTS has the Best Answer!


“Can your sterilizer process different kinds of instruments all at the same time?”
“Can it finish processing in as fast as 35 minutes?”
“Does it have an established track record of durability, quality, and performance?”
“Is it safe for both users and the environment?”
“Is it cost-efficient?”
HMTS-80E
Dimensions and Weight
Size Width 750 mm Height* 1670 mm Depth 835 mm *Including built-in wheels
Weight 430 kg

Sterilization Chamber
Total Volume 80 L (2.83 cubic feet)
Usable Volume 71 L (2.5 cubic feet)
Dimensions (W x H x D) Ø400 mm x 650 mm (D) (Ø15.7 in x 25.6 in)
Shelf Strength 35 kg (77 lbs)
Shelf Dimensions (W x D) Upper: 380 mm x 635 mm (14.9 in x 25 in) Lower: 260 mm x 635mm (10.2 in x 25 in)

Sterilization System Cycle Normal cycle (Dual cycle)


Vacuum 1 Stage Initial evacuation of sterilization chamber to basal vacuum, 7-8 min
Diffusion 1 Stage Automatic injection and diffusion stage of 3.5 cc H202, 8-9 min
Vacuum 2 Stage Re-evacuation of sterilization chamber to 500m Torr, 2-5 min
with Plasma 1 Stage
Diffusion 2 Stage Automatic injection and diffusion stage of 3.5 cc H2O2, 8-9 min
Plasma 2 Stage Re-evacuation of sterilization chamber to basal vacuum, 2-4 min
Vent & Dry Run Stage Return of sterilization chamber to atmospheric pressure and re-evacuation of chamber, 4-6 min
Total Cycle Time 1 Phase 35 ~ 40 Minutes
Chamber Material Stainless Steel
Cycle time varies depending on the type of load being sterilized.
Installation and Operating Requirements
Electricity 220~240 VAC, 50/60 Hz, 3.5KW, 1-Phase
200/208/220/240/380/400/415VAC, 50/60 Hz. 5KW, 3-Phase
Placement Built-in wheels provide mobility
Operational Environment Temperature: 18°C – 35°C (64.4°F – 95°F) Humidity: 10% – 85% RH (Non-condensing)
Installation space Minimum area: 1290 mm x 1750 mm (50.7 in x 68.8 in) Surface: Flat = 5 mm/m (0.188 in / 3 feet)
Minimum distance from wall: 300 mm (11.8 in) Minimum service access: 1 m (3 feet) on all sides

Features
Operating system Windows Embedded (Standard 7)
User interface 6.4” TFT Touch Monitor and Audible/Voice Alarm
Network 100/10 Mbps Ethernet
Print Built-in thermal printer
Self-test Functions are available

Regulatory Approvals Normative Reference


1) Medical Devices Directive 93/42/EEC 1) ISO 14971: 2007 Medical Device. Application of risk management
2) ISO 13485: 2016 Quality management systems - Medical devices to medical devices
- Design, development and manufacture of low temperature 2) ISO 14937: 2009 Sterilization of health care products
hydrogen peroxide sterilizer and hydrogen peroxide sterilant 3) ISO 10993-5: 2009 Biological evaluation of medical devices
agent for use in HMTS series. – Part 5: Tests for in vitro cytotoxicity
3) KGMP (Korea Good Manufacturing Practice) 4) EN 61010-1: 2010 Safety requirements for electrical equipment
for measurement, control and laboratory use. General requirements.
LL-80E (Rev.15) 5) EN 61010-2-040: 2015 Particular requirements for sterilizers and
washer-disinfectors used to treat medical materials
6) EN 60601-1-2: 2015. Medical electrical
equipment. General requirements for safety. Collateral standard.
Electromagnetic compatibility. Requirements and tests.
* Product descriptions and images are subject to change without notice.