ACCESS AND CONTENTS OF MONITOR DISPLAYS (Diagnostic mode)

Access to monitor displays


Key switch turned "ON"

Normal display (Coolant temperature, hydraulic oil temperature, fuel level, travel mode, work mode,
idle mode)
A
D C

Machine Diagnostic Machine Re-


B B B E
condition code history initialisation

CHK1 DIAG1 HR12 C HR1 RST1

C C C
C

CHK2 DIAG2 HR11 HR2

C C C
C

CHK3 DIAG3 HR10 HR3

F C C C
C

CHK4 DIAG4 HR9 HR4

C C C
C

CHK5 DIAG5 HR8 HR5

G C C
C

CHK6 DIAG6 HR7 HR6

C C

A. Press the travel mode and work mode switches E. To re-initialise the system, press the audible alarm
simultaneously for a minimum of 3 seconds. cut out switch.
B. Press the auto work mode switch. To programme the system, press the travel mode
switch.
C. Press the audible alarm cut out switch.
To erase the data, press the work mode switch for a
D. To erase the data, press the work mode switch for a minimum of 10 seconds and the audible warning
minimum of 10 seconds and the audible warning device sounds.
device sounds. F. To initialise the automatic overload detection on the
electrical circuit, press the travel mode switch.
G. To initialise the automatic detection of short-circuits,
press the travel mode switch for a minimum of
10 seconds and the audible warning device sounds.