PDU For Uninterruptible Power Systems

60~150kVA

4256-5105 D

Operation Manual
All rights reserved.
The information in this document is subject to change without notice.

Publish statement
Thank you for purchasing this series UPS.
This series UPS is an intelligent, three phase in Three phase out, high frequency online
UPS designed by our R&D team who is with years of designing experiences on UPS.
With excellent electrical performance, perfect intelligent monitoring and network
functions, smart appearance, complying with EMC and safety standards, The UPS
meets the world’s advanced level.
Read this manual carefully before installation
This manual provides technical support to the operator of the equipment.
Contents
1.Safety....................................................................................................................................... 2
1.1 Safety notes ....................................................................................................................................... 2
1.2 Symbols used in this guide............................................................................................................ 2
2.Installation.............................................................................................................................. 3
2.1 Unpack checking .............................................................................................................................. 3
2.2 The appearance of the product ..................................................................................................... 3
2.3 UPS Common input connection ................................................................................................... 7
2.4 UPS Dual input connection ............................................................................................................ 8
2.5 PDU-UPS-Load connecting .......................................................................................................... 10

1
1.Safety
Important safety instructions – Save these instructions

There exists dangerous voltage and high temperature inside the PDU. During the
installation, operation and maintenance, please abide the local safety instructions and relative
laws, otherwise it will result in personnel injury or equipment damage. Safety instructions in this
manual act as a supplementary for the local safety instructions. Our company will not assume the
liability that caused by disobeying safety instructions.

1.1 Safety notes


1. Even no connection with PDU, 220/230/240VAC voltage may still exist at connector!

2. For the sake of human being safety, please well earth the PDU before starting it.

3. Don’t disassemble the PDU cover, or there may be an electric shock!

1.2 Symbols used in this guide

WARNING!
Risk of electric shock

CAUTION!
Read this information to avoid equipment damage

2
2.Installation

2.1 Unpack checking


1. Don’t lean the PDU when moving it out from the packaging

2. Check the appearance to see if the PDU is damaged or not during the transportation, do
not switch on the PDU if any damage found. Please contact the dealer right away.

2.2 The appearance of the product

60kVA Front view

150kVA Front view

PDU include 4 breaker : Mains breaker, bypass breaker, maintenance breaker and output breaker

60kVA Side view

3
150kVA Side view

Remove the top cover of copper bar

60kVA Top view (common input, remove cover)

60kVA Top view (dual input, remove cover)

4
150kVA Top view (common input, remove cover)

150kVA Rear view (dual input)

5
150kVA Rear view (dual input, remove insulation)

(1) Mains_L1_IN : PDU mains intput, connect to mains source L1

(2) Mains_L2_IN : PDU mains intput, connect to mains source L2

(3) Mains_L3_IN : PDU mains intput, connect to mains source L3

(4) Mains_L1_Out : PDU mains output, connect to UPS mains_L1

(5) Mains_L2_Out : PDU mains output, connect to UPS mains_L2

(6) Mains_L3_Out : PDU mains output, connect to UPS mains_L3


(7) Bypass_L1_IN : PDU bypass intput, connect to bypass source L1 or mains source L1
(common input)
(8) Bypass_L2_IN : PDU bypass intput, connect to bypass source L2 or mains source L2
(common input)
(9) Bypass_L3_IN : PDU bypass intput, connect to bypass source L3 or mains source L3
(common input)
(10) Bypass_L1_Out :PDU bypass outtput, connect to UPS bypass_L1

(11) Bypass_L2_Out :PDU bypass outtput, connect to UPS bypass_L2

(12) Bypass_L3_Out :PDU bypass outtput, connect to UPS bypass_L3

(13) Output_L1_IN : PDU output intput, connect to UPS Output_L1

(14) Output_L2_IN : PDU output intput, connect to UPS Output_L2

(15) Output_L3_IN : PDU output intput, connect to UPS Output_L3

(16) Output_L1_Out : PDU output, connect to Load L1

(17) Output_L2_Out : PDU output, connect to Load L2

(18) Output_L3_Out : PDU output, connect to Load L3

(19) MAINTAIN- AUXSWS : maintenance breaker contactor connector (Normally closed)

(20) Output-AUXSWS : output breaker contactor connector (Normally closed)

(21) :Grounding terminal


6
2.3 UPS Common input connection

20kVA-60kVA

40kVA-120kVA

60kVA-150kVA

7
INPUT Primary input Line OUTPUT
Vout-L1: Output Phase L1
Vin-L1: Primary input Phase L1 Vout -L2: Output Phase L2
Vin-L2: Primary input Phase L2 Vout -L3: Output Phase L3
Vin-L3: Primary input Phase L3 Vout -N: Output Neutral
Vin-N: Input Neutral for primary and
PE: Grounding
secondary input
BAT+: Positive terminal of the batteries string
BATN: Neutral terminal of the batteries string
BAT-: Negative terminal of the batteries string

2.4 UPS Dual input connection

20kVA-60kVA

40kVA-120kVA

8
60kVA-150kVA

Mains Primary input Line Output


Bypass Secondary/Bypass input line
Vout-L1: Output Phase L1
(optional)
Vin-L1: Primary input Phase L1 Vout-L2: Output Phase L2
Vin-L2: Primary input Phase L2 Vout-L3: Output Phase L3
Vin-L3: Primary input Phase L3 Vout-N: Output Neutral
Vin-N: Input Neutral for primary and
PE: Grounding
secondary input
BPS-L1: Secondary input Phase L1 BAT+: Positive terminal of the batteries string
BPS-L2: Secondary input Phase L2 BATN: Neutral terminal of the batteries string
BPS-L3: Secondary input Phase L3 BAT-: Negative terminal of the batteries string

9
2.5 PDU-UPS-Load connecting
Choose appropriate power cable. (Refer to the table above) and pay attention to the
diameter of the connection terminal of the cable that should be greater than or equal to that of
the connection poles;

2.5.1 Common input wiring

2.5.2 Dual input wiring

10