DOOSAN G2 Stage5 (De-tier) Trouble shooting guide

Revision v.1.64
PAGE 313 / 933

Fault Code Fault Name


P025D Fuel metering unit Short circuit to Battery fault
1) Overview

“E” SPN-FMI REASON EFFECT


1. Electrical problem (Metering unit connector)
2. Electrical problem (Wiring harness from Metering unit to CE lamp ON
E004082-03
ECU, Faulty Metering unit) Torque Reduction 1(Mild)
3. Electrical problem (Faulty ECU, ECU connection)

No ECU Pin Description


1 A7 Fuel metering unit supply
2 A6 Fuel metering unit signal

2) Component Location

Copyright by Doosan Infracore Co., Ltd. Rights Reserved.


DOOSAN G2 Stage5 (De-tier) Trouble shooting guide
Revision v.1.64
PAGE 314 / 933

3) Condition for Running Diagnostic


Key on or engine running or Key off(ECU on)

4) Condition for Setting the Fault Code


If the fuel metering unit signal is short circuit to battery, fault code is raised.

5) Condition for Clearing the Fault Code


If the fault condition is restored, fault code is cleared.

6) Check List
Standard
Step Inspection YES NO
Value
1 P025D is detected on service tool? Step 2

2 Let the machine be in safety area, and key OFF Step 3

3 Check the Fuel Metering unit connection Step 4

Copyright by Doosan Infracore Co., Ltd. Rights Reserved.


DOOSAN G2 Stage5 (De-tier) Trouble shooting guide
Revision v.1.64
PAGE 315 / 933

Connection problem? (pin to pin) Do necessary


repair
Check the ECU Connection. Do necessary
4 Step5
Connection problem? repair

Measure Fuel Metering unit electrical resistance?


2.6~3.15 Ω Change Fuel Contact
5 (Pin#1 & #2)
@ 20 degC metering unit Helpdesk
Resistance problem?

* The service tool supports the “Metering unit test” function for related checking.