ELGAS, s.r.o.

Semtínská 211 Ohrazenice 533 53 Pardubice IČO 47469978

Metrological centre

CALIBRATION CERTIFICATE
№. 1933 / 2018
Test : Performed according to Procedure PI 006, Accuracy at reference conditions
Date of issue: 2018-03-22 Page: 1 of 2

Zdeněk Alinče
MC Officer
Applicant:

Device under test: Volume Conversion Device


Model: miniELCOR, FW : 4.06 CRC EC4C
Type: 1 (complete system) Mnfr: ELGAS, s.r.o.
Serial number: 1809000708
pressure transducer: 1682600416
Measuring ranges: Pressure: ( 7.00 to 35.00 ) bar a.
Power voltage: battery powered

Test equipment used:


Pressure calibrator GE company PACE6000, CM2-B-10G s. n. 10884045
range ( 0 to 800 ) kPa a. 6013-KL-C0025-18
U (k=2) ± ( 0.005 %MV + 0.005 %FS )
Pressure calibrator GE company PACE6000, CM2-B-16G s. n. 10889108
range ( 0 to 7100 ) kPa a. 6013-KL-C0026-18
U (k=2) ± ( 0.005 %MV + 0.005 %FS )

Conditions in laboratory Temperature: ( 23.00 ± 1 ) °C Rel. humidity: ( 30.00 ± 5 ) %


Conditions of DUT Temperature: ( 23.00 ± 1 ) °C Rel. humidity: ( 30.00 ± 5 ) %
Barometric pressure: ( 99.41 ± 0.5 ) kPa a.

Document is not valid without signature(s) of the authorized persons. Document can be copied only whole as it is and with
no changes. Changes can be made only by the laboratory that issued this document. program v. 03.04.09.07
CALIBRATION CERTIFICATE №. 1933 / 2018 Page: 2 of 2
Test results

pr conventional true value of pressure


p pressure value measured by DUT
difference value = P - pr
error value = ( difference / MV ) * 100
U expanded uncertainty, k=2

incrementation decrementation

pr p differ. error U pr p differ. error U


[bar a.] [bar a.] [bar] [%MV] [%MV] [bar a.] [bar a.] [bar] [%MV] [%MV]
7.0000 7.0013 0.0013 0.019 0.05 7.0000 7.0003 0.0003 0.004 0.05
14.0000 14.0019 0.0019 0.013 0.05 13.9999 14.0008 0.0009 0.006 0.05
21.0000 21.0024 0.0024 0.011 0.05 21.0000 21.0024 0.0024 0.012 0.05
28.0000 28.0056 0.0056 0.020 0.05 28.0000 28.0061 0.0062 0.022 0.05
35.0000 35.0051 0.0051 0.015 0.05 35.0000 35.0051 0.0050 0.014 0.05

Date of test: 2018-03-22 Eva Dimovová

Checked by: Gabriela Bucharová


The mentioned expanded uncertainty of measurement results is obtained by multiplying
combined standard uncertainty uc by coverage factor k = 2, what, for normal distribution defines
an interval having level of confidence of approximately 95%.
Standard uncertainty of measurement results was evaluated in compliance with the document EA-4/02.
Used abbreviations:
FS Full Scale MV Measured Value (reading)
kPa a. kPa absolute DUT Device under test