Professional Documents
Culture Documents
STart Max
STart Max
This document contains information on products which is targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country.
- © Diagnostica Stago - All rights reserved - Non-contractual photos - 06/2016 - Ref: 29621
TECHNICAL Operating conditions Sample and reagent management
SPECIFICATIONS 5-32°C
1 6 incubation wells at 37°C
1
umidity 20-80%
H (4 cells x 4 columns)
Dimensions measuring channels
4
H 100 mm x W 360 mm x D 330 mm Connectivity and interface (4 cells x 1 column)
Weight 2.62 kg ’’ colour touch-screen
7 positions for reagents at 37°C
2
USB ports Type A for printer
2 (one stirring position) and
Power supply: and external drive 2 positions at room temperature
oltage: 100 to 240 V
V
mini USB port for handheld
1
Frequency: 50 / 60 Hz
Maximum Power: 65 W
barcode reader
S 232 unidirectional interface
R
onnected pipette
C
Disposable
ivisible strips of 4 cuvettes
D
One steel ball dispenser
Simplicity born from Expertise
For further information, please contact:
Diagnostica Stago S.A.S.
RCS Nanterre B305 151 409
3 allée Thérésa
92600 Asnières sur Seine
France
Ph.: +33 (0)1 46 88 20 20
Fax: +33 (0)1 47 91 08 91
webmaster@stago.com
www.stago.com
STart Max
Max Innovation
New hardware design to enhance ease of use Extended traceability enhances regulatory
Max Reliability ’’ colour touch-screen with virtual keyboard
7 compliance:
Optional external handheld barcode reader for omplete management of reagents, QC
C
patient sample identification and quick choice of information, patient results and calibration data
test setup Tracking of all events, changes and operators
Viscosity-Based (mechanical) Comprehensive benchtop USB connectivity for an external printer and through login/logout feature
Detection System consistently delivers haemostasis solution an external drive New back up function for patient, QC and
accurate and precise results
Proven reliability and robustness of calibration data on an external drive
E xclusive technology standardised
Stago semi-automated STart line analysers
Intuitive graphical user interface to ensure a
on all Stago systems seamless integration for laboratory staff Connectivity with STA Coag Expert® software
Insensitive to interferences from Environmentally friendly design: standardised on all Max Generation systems or
coloured plasma (haemolysis, icteric Limited solid waste with unique divisible directly with the LIS*
and lipemic samples) cuvette strips and no liquid waste
Maximum precision for weak clot
detection (Fibrinogen)