Professional Documents
Culture Documents
Water Table at Depth 3m From Ground Level: Marks CO R.B.T. Level
Water Table at Depth 3m From Ground Level: Marks CO R.B.T. Level
OR
Discuss about the negative skin friction of pile, and write the set of formulae for negative
2a) skin friction in different soils. 12 5 2
A nine pile group arranged in a square pattern is used as a foundation for a column in sand
angle of internal friction is 320 . piles 300mmin diameter and 10m in length, are placed at a
2b) spacing of 900mm in each direction. Calculate the ultimate load capacity of the pile group. 13 5 3
Assume then unit weight of the soil as 18kN/m3. Use Nq =27 , K= 1.0, ẟ= 3/4 of 320
Part –B
Explain the standard penetration test for determining the bearing capacity of soil in field.
3a) 12 4 2
Determine the allowable pile load capacity of 40 cm dia., Driven concrete pile shown in
fig below, given K=1, ẟ= 3/4 of angle of internal friction, Nq= 144. water table at depth 3m
3b) from Ground Level 13 5 3
5m
Dense sand, saturated unit weight 20kN/m3,
angle of internal friction= 400
OR
Describe the types pf pile based on materials, function and installation, and write about
4a) 12 5 2
underreamed piles with neat diagram.
A 300mm diameter concrete pile 10m long, was driven by a Mckiernan ans Terry double
4b) acting hammer(rated energy is 16.62kJ, total mass 2200kg). the driving was done with a 13 5 3
short dolly and cushion 2.50m. the average penetrationn recorded in the last five blows was
3.0mm/blow. Calculate the safe pile load .