Professional Documents
Culture Documents
F13278 Ace300 114116 Broch GB 0104
F13278 Ace300 114116 Broch GB 0104
F13278 Ace300 114116 Broch GB 0104
Key Benefits
High Measurement Accuracy ACE300 1 16 series meters are designed to meet the most stringent requirements for 14/1 residential, commercial and industrial applications. They are available in a wide variety of configurations to suit the distribution network: Active energy meters Class 1 accuracy for transformer connection Class 2 accuracy for direct and transformer connection Reactive energy meters Class 3 accuracy for direct and transformer connection Class 1 and 2 meters meet IEC 62053-1 (formerly IEC 60521) 1 Class 3 meters meet IEC 60145. Long-term Stability The use of robust construction techniques, precision bearings and a high torque driving system ensure that ACE300 1 16 series meters combine excellent metrological characteristics with 14/1 long-term stability. Accelerated life testing has shown that the Actaris Ferraris meters provide satisfactory operation in networks for more than 40 years. Load Capacities of up to 1000% The ACE300 1 16 series of meters caters for a wide variety of load capacities; models with 14/1 400%, 500%, 600%, 800% and 1000% load capacities are available. Direct Connection up to 160A The layout and diameter of the current terminals in ACE300 C1 series direct connected 14 meters enable currents of up to 160A to be accommodated. The terminals are suitable for copper and aluminium cables. Choice of Connection Styles ACE300 1 16 series meters are available with asymmetrical (DIN) or symmetrical (UTE) 14/1 connections, and can be equipped with optional auxiliary terminals for signalling purposes. Fraud Prevention ACE300 1 16 series meters offer a number of features to help to minimise fraud: 14/1 Main cover and terminal cover can be sealed separately Reverse running stop Voltage links under the main cover (internal voltage links)
Accuracy class 2.0 - ACE300 C1 14U 10 (60)A At rated voltage UN 50 Hz or 60 Hz and at 23C (IN = rated current)
Features
Main Cover Tinted transparent (standard), or bakelite with glass window (special version). Baseplate Bakelite, and integrated with terminal block. Terminals protected by glass fibre polycarbonate insulator. Terminal Cover Bakelite or polycarbonate, depending upon cable space requirements. Upper Hanger Adjustable to 2 positions (fixing screw can be hidden). Cable Inputs Sloped, to facilitate installation of cables in terminal block. Upper Bearing Highly-polished, precision-ground guide pin. Lower Bearing Double jewel (standard) or magnetic system. Registers Mechanical single-tariff, DIN version Mechanical single-tariff, BS version with large drums Mechanical double-tariff, DIN version
Optional Features
Internal or external voltage links Voltage failure indicator Pulse emitter with S0 interface according to DIN 43864/IEC 62053-31 Type A Pulse emitter with potential-free pulse output Dual-voltage versions
Voltage Ranges
Four-wire meters 3x58/100V to 3x290/500V 50 or 60Hz Three-wire meters 3x100V to 3x500V
Product Variants
Direct connected meters
Four-wire meters
Accuracy Energy type Current rating in Amps 10 (40) 20 (80) 20 (100) 5 (30) 10 (60) 20 (120) 5 (40) 10 (80) 20 (160) 5 (50) 10 (100) 10 (40) Class 3 Reactive 5 (30) 5 (40) 5 (50) 10 (60) 10 (80) 10 (100) 20 (80) 20 (100) 20 (120) 20 (160) 30 (120) 25 (150) Model ACE300 C1 14G ACE300 C1 14N ACE300 C1 14U ACE300 C1 14K ACE300 C1 14T ACE300 BVC1 14G ACE300 BVC1 14N ACE300 BVC1 14U ACE300 BVC1 14K ACE300 BVC1 14T
Class 2
Active
50 or 60Hz
30 (120) 25 (150)
Three-wire meters
Accuracy Class 2 Class 3 Energy type Active Reactive Current rating in Amps 10 (40) 20 (80) 5 (30) 10 (60) 20 (120) 5 (30) 10 (40) 10 (60) 20 (80) 20 (120) 30 (120) 25 (150) 30 (120) 25 (150) Model ACE300 B1 14G ACE300 B1 14U
EL-001 1.0-GB-01.04 - Copyright 2002, Actaris. All Rights Reserved. - Actaris reserves the right to change these specifications without prior notice.
Three-wire meters
Accuracy Class 2 Energy type Active Current rating in Amps (secondary) 1 5 5 (10) 1 Class 3 Reactive 1 Class 1 Active 5 5 (10) 5 5 (10) Model ACE300 B1 14W-0.2/1.2 ACE300 B1 14W-1/6 ACE300 B1 14W-1.66/10 ACE300 BVB1 14W-0.2/1.2 ACE300 BVB1 14W-1/6 ACE300 BVB1 14W-1.66/10 ACE300 B1 16W-0.2/1.2 ACE300 B1 16W-1/6 ACE300 B1 16W-1.66/10
Actaris Ganz Meter Company Ltd. Tncsics M. u. 11. H-2101 Gdll - Hungary For more information, www.actaris.com tel +36 28 520 600 fax +36 28 520 605