ALMANSOORI INSPECTION SERVICES

LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT


This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Report Number: 5010025517-WH-003 Date of Report: 04-Jun-2020
Job Allocation No: 5010025517 Type of Inspection: Visual & Function Test
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-51 Rig Floor-Driller Side
Due Date of Next Date of Last Proof Due Date of Date of Last
Date of Inspection
Inspection Load Test Next Proof Load Test Inspection
04-Jun-2020 03-Sep-2020 05-Mar-2020 04-Mar-2021 05-Mar-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)
Man Rider winch and foundation
150 kg N/A
Sticker No: 15584
Motive Power: Pneumatic Manufacture Year of
150231 1
Model: 150RLP-CE Name Manufacturing
Wire Rope Details: Single leg wire rope sling terminated
with spelter on one end, other end plain. Ingersoll Rand
Ingersoll Rand
10mmx 450 ft. SWL: 1.3 t COC
Applicable Reference Standards : ASME B30.7
Applicable Reference Regulations: SWIM Sec.38
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details:
Is this the first examination after installation or assembly at a new site or location? : Yes☐ No☒
If the answer to the above question is YES, has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & Function Test
IS THIS EQUIPMENT SAFE TO USE? YES☒ NO☐
Remarks (if Any) :
Inspected By Inspector Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT LEVEL II

Signature:

Name and address of employer of persons making and reviewing this report:
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer,
manufacturer, seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the willful negligence or deliberate
omissions of its employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of
negligent operation or any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards
and only those items actually inspected by AlMansoori and which are covered by this certificate.

F. 836
Rev. 03
28.11.2018

ALMANSOORI INSPECTION SERVICES


MAN RIDING POWER OPERATED WINCHES CHECKLIST
Identification No : 150231 Report Number : 5010025517-WH-003 Date of Inspection : 04-Jun-2020
Client name : Arabian Drilling Co. CL No : 40 WI No : 43
Inspection shall be compliance with ASME B 30.7 and Aramco SWIM and General Safety features
SR# Inspection check points Status Remarks
Certification information
1. Proof load test certificate Yes
2. Recent periodic inspection record condition of the winch. Yes
3. Last thorough visual examination & NDT report Yes
4. Declaration of conformity Yes
5. Other (specify)
Physical markings
6. Winch rating Yes
7. Drum size consisting of barrel diameter, barrel length, and flange diameter Yes
8. Rope diameter(s) Yes
9. Rope speed in feet per minute (mtr/sec) at rated load on specified layer Yes
10. Power requirement Yes
Aramco SWIM design requirement
11. Hoist operating lever which will come neutral from any operating position Yes
12. An automatic brake Yes
13. Certified rotation resistant winch line. Yes
14. Provision of a secondary brake. Yes
15. A clutch capable of disengaging the drum shall not be fitted. Yes
16. Upper and lower limit devices Yes
17. Slack wire detector device Yes
18. Overload protection to limit pulling force to 150 KG (330 LB.). Yes
19. The hoist shall be fitted with an emergency stop device. Yes
20. Specific written instructions Yes
21. Welded name on winches frames “man riding hoist” Yes
Inspection & test
22. Control mechanisms for proper operation OK
23. Limit devices for proper operation OK
24. Deterioration or leakage in air or hydraulic systems OK
25. Ropes for excessive wear, damage, or distortion (Refer ASME 30.7 Sec 7-2.4.2) OK
26. Ropes shall be away from mast structure OK
27. Rope end securement and fittings at the working end OK
28. Indication of loose, damaged, or missing structural components OK
29. Indication of loose, damaged, or missing supports and anchorages OK
30. Any additional items specified by the manufacturer OK
31. Any adjustments and repairs by unauthorized person N/A
32. Replacement parts from different manufacturers N/A
33. Control and drive mechanisms for improper adjustment N/A
34. Control and drive mechanisms for excessive wear N/A
35. Tubing, piping, electrical cables, or hoses and their fittings for damage N/A
36. Fluids for adequate condition and supply N/A
37. Gearboxes and lubrication systems for oil level N/A
38. Gearboxes and lubrication systems for clogged filters N/A
39. Hydraulic oil reservoir for proper level(s) N/A
Operational Tests in no load conditions
40. Drum rotation , Clutches, brakes, and pawls, Limit devices and all other aids OK
Load test
41. Minimum of five wraps of rope on the drum during the load test. N/A
42. The load shall be applied to the winch and held by the winch brake(s). N/A
43. Load test for 100% SWL (Periodic load test ) N/A
44. Proof test for 110-125% SWL (New, repaired or altered Winches) N/A
45. Photo of the load cell with reading (if load test conducted) N/A
Comments & Observations (that could become a potential hazard and/or danger to personnel)

Inspector name and signature: Mohamed Yasir