Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

SCHEDULE OF COLUMNS

RINGS AS PER ELEVATION


18"
MAIN BAR
ROOF 6#4

6"
18"
01 02 03 04 05 06
COLUMN C1 TO

6"
(11 NOS.)
4'-6" 7'-0" 7'-0" 4'-6" 10'-6"
PLINTH (6"x18")
MAIN BAR
PLINTH 6#4

18"

TO

6"
3" 9" 3" 3"
FOUNDATION (6"x18")

C
3"

3"

3"

3"
C1 C1 C1 C1 LEVELS C1
(11 NOS.)

18"
10'-0"

ROOF

3" 3"
3"

3"
9"

9"
C1

12'-0"
C1 C1
#3@9"c/c

6#4
10'-6"

(TYP.)
3" P.L
3" 3" 3"

1'-6"
VARIES
A
3"

3"

3"

3"
C1 C1 C1 C1 #3@5"c/c

6#4

6'-0"
COLUMN LAYOUT PLAN

6" 4" 12"


4" THICK LEAN
6" THICK STONE SOLING

TYPICAL COLUMN ELEVATION


SCALE 1/4" = 1'-0"

CONSULTANT CLIENT PROJECT TITLE REVISION DESIGNED BY SCALE N.T.S CODE


A.H.M DRAWING NO. ST-WWBS-01
WORKERS WELFARE REHABILITATION/ RENOVATION SUB ENGINEERS DRAWN BY JOB NO. -
WWBS
atif nazar (pvt.) ltd. BOARD SINDH LABOUR SQUARE 1000 FLATS OFFICE
AHSAN DATE
REVISION
FEB-2022
0
PROJECT MANAGERS, PLANNERS, ARCHITECTS & CONSULTING ENGINEERS 23-2-2022 ISSUED FOR CONSTRUCTION
CHECKED/CO-ORDINATED
GULSHAN E MAYMAR KARACHI 0 AHSAN

D-11/A, BLOCK NO-17, GULSHAN-E-IQBAL, KARACHI. P.H. 34820497 - 34982561


NO. DATE DESCRIPTION REV. BY A.H.M SHEET SIZE A3
B

SCHEDULE OF R . C . C . FOOTING

L
SIZE DEPTH REINFORCEMENT
MARK REMARK
A B D S L
F1 3'-6" 4'-6" 12" #4@8"C/C #10@10"C/C -

A
F2 4'-6" 5-6" 12" #4@8"C/C #10@10"C/C -
A A
00 S 00
01 02 03 04 05 06
4'-6" 7'-0" 7'-0" 4'-6" 10'-6"
TYPICAL FOOTING DETAIL
5'-6" 5'-6" SCALE 3/16" = 1'-0"
4'-6" 4'-6"
2'-9" 2'-9" 3'-3" 2'-3"
1'-9" 2'-9" 2'-9" 1'-9"
2'-3" 2'-3"

2'-3" 2'-3"
1'-9" 1'-9"

1'-9" 1'-9"
4'-6"

4'-6"
3'-6"

3'-6"
C
F1 F2 F2 F1
P.L

4'-6" 4'-6"
10'-0"

5'-6"

1'-6"
2'-3" 2'-3" 2'-3" 2'-3"
3'-3" 2'-3"
2'-9"

2'-9"
2'-3" 2'-3"

VARIES
4'-6"
5'-6"

5'-6"
B
2'-9"

2'-9"
F2 N.G.L
F2 F2

3'-6"
10'-6"

5'-6" 5'-6"
1'-9" 1'-9" 4'-6"

6'-0"
2'-3" 3'-3" 2'-3" 3'-3"
2'-9" 1'-9"

6" 4" 12"


1'-8" 2'-10"

1'-8" 1'-10"
2'-3" 2'-3"

2'-3" 2'-3"
4'-6"

4" THICK LEAN


3'-6"
4'-6"
4'-6"

A 6" THICK STONE SOLING


F1 F2 F1
F2 L
S

FOUNDATION LAYOUT PLAN SECTION A - A


SCALE 3/16" = 1'-0"

CONSULTANT CLIENT PROJECT TITLE REVISION DESIGNED BY SCALE N.T.S CODE


A.H.M DRAWING NO. ST-WWBS-02
WORKERS WELFARE REHABILITATION/ RENOVATION SUB ENGINEERS DRAWN BY JOB NO. -
WWBS
atif nazar (pvt.) ltd. BOARD SINDH LABOUR SQUARE 1000 FLATS OFFICE
AHSAN DATE
REVISION
FEB-2022
0
PROJECT MANAGERS, PLANNERS, ARCHITECTS & CONSULTING ENGINEERS 23-2-2022 ISSUED FOR CONSTRUCTION
CHECKED/CO-ORDINATED
GULSHAN E MAYMAR KARACHI 0 AHSAN

D-11/A, BLOCK NO-17, GULSHAN-E-IQBAL, KARACHI. P.H. 34820497 - 34982561


NO. DATE DESCRIPTION REV. BY A.H.M SHEET SIZE A3
01 02 03 04 05 06 SCHEDULE OF PLINTH BEAMS

SIZE BOTTOM BARS


TOP EXTRA TOP RINGS
MARKS SPAN REMARK
WIDTH DEPTH MAIN BARS CURTAIL BARS BARS LEFT SUPP. RIGHT SUPP. UPTO 2D FROM SUPP.
4'-6" 7'-0" 7'-0" 4'-6" 10'-6" 1 6" 18" 2#4 - 2#4 - - #3@6" c/c
MID SPAN
#3@10" c/c -
PB-1 2 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
3 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-2
2 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-3 1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-4 2 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
3 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-5
2 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-6 1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-7 1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-8 1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
PB-1 PB-9 1 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -
C PB-10
PB-11
1
1
6"
6"
18"
18"
2#4
2#4
-
-
2#4
2#4
-
-
-
-
#3@6" c/c
#3@6" c/c
#3@10" c/c
#3@10" c/c
-
-
2 6" 18" 2#4 - 2#4 - - #3@6" c/c #3@10" c/c -

PB-7

PB-9
10'-0"

00 00
UP

A A
1'-5" 3'-0"
8" 8" 8" 8" 6"

PB-11
2#4
PB-5

PB-2 P.L.
B
Cast In SITU

4'-1"

18"
#3@6"/10"/6"

PB-3
10'-6"

2#4
SECTION A-A

PB-10
PB-10
PB-6

PB-8
TYPICAL SECTION
OF BEAM

A PB-4 6"
P.L.

PLINTH BEAM FRAMING PLAN

18"
Plinth Beam
ALL BEAM ARE 6"X18" 6"
P.L.
1" 1"

Varies

18"
Plinth Beam
2 #4 2#4 C.C. 1:3:6
N.G.L
C.C. 1:4:8

4" 6"
#3@6"C/C #3@10"C/C

4"
#3@6"C/C #3@6"C/C #3@10"C/C #3@6"C/C
C.C. 1:4:8

2#4 2#4 4" 4"


TYPICAL SECTION TYPICAL SECTION
TYPICAL PLINTH BEAM ELEVATION
SCALE 1/4" = 1'-0"
OF EXTERNAL BEAM OF INTERNAL BEAM

CONSULTANT CLIENT PROJECT TITLE REVISION DESIGNED BY SCALE N.T.S CODE


A.H.M DRAWING NO. ST-WWBS-03
WORKERS WELFARE REHABILITATION/ RENOVATION SUB ENGINEERS DRAWN BY JOB NO. -
WWBS
atif nazar (pvt.) ltd. BOARD SINDH LABOUR SQUARE 1000 FLATS OFFICE
AHSAN DATE
REVISION
FEB-2022
0
PROJECT MANAGERS, PLANNERS, ARCHITECTS & CONSULTING ENGINEERS 23-2-2022 ISSUED FOR CONSTRUCTION AHSAN CHECKED/CO-ORDINATED
D-11/A, BLOCK NO-17, GULSHAN-E-IQBAL, KARACHI. P.H. 34820497 - 34982561 GULSHAN E MAYMAR KARACHI 0

DESCRIPTION REV. BY A.H.M A3


NO. DATE SHEET SIZE
01 02 03 04 05 06
4'-6" 7'-0" 7'-0" 4'-6" 10'-6" SCHEDULE OF ROOF BEAMS

SIZE BOTTOM BARS TOP EXTRA TOP RINGS


MARKS SPAN REMARK
WIDTH DEPTH MAIN BARS CURTAIL BARS BARS CONTINOUS SUPP. UPTO 2D FROM SUPP. MID SPAN
1 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
RB-1 2 6" 18" 2#4 - 2#4 1#4 #3@6" c/c #3@10" c/c -
3 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
1 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
RB-2 1#4
2 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
RB-3 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -
1 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
RB-4 2 6" 18" 2#4 - 2#4 1#4 #3@6" c/c #3@10" c/c -
RB-1 3 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -
C RB-5
1
2
6"
6"
18"
18"
2#4
2#4
-
-
2#4
2#4
1#4
#3@6" c/c
#3@6" c/c
#3@10" c/c
#3@10" c/c
-
-
RB-6 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -
RB-7 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -
RB-8 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -
RB-9 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -

RB-7

RB-9
RB-10 1 6" 18" 2#4 - 2#4 - #3@6" c/c #3@10" c/c -
10'-0"

1 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -


RB-11 1#4
S1 S1 S1 2 6" 18" 2#4 - 2#4 #3@6" c/c #3@10" c/c -

1'-5" 3'-0"

RB-11
RB-5

RB-2
B

4'-1"
S4
6 6
RB-3 2#4 2#4

RB-10
RB-6

RB-8
10'-6"

S3 S2 S3 S1
1#4

RB-10

18

18
S4 #3@6"/10"/6" #3@6"/10"/6"

2#4 2#4
A RB-4 TYPICAL SECTIONS
OF BEAM

ROOF FRAMING PLAN


ALL BEAM ARE 6"X18"
ALL SLABS ARE 5" THICK

L/3 L/3
(TYP.) (TYP.)

TYPICAL BEAM ELEVATION


SCALE 1/4" = 1'-0"

CONSULTANT CLIENT PROJECT TITLE REVISION DESIGNED BY SCALE N.T.S CODE


A.H.M DRAWING NO. ST-WWBS-04
WORKERS WELFARE REHABILITATION/ RENOVATION SUB ENGINEERS DRAWN BY JOB NO. -
WWBS
atif nazar (pvt.) ltd. BOARD SINDH LABOUR SQUARE 1000 FLATS OFFICE
AHSAN DATE
REVISION
FEB-2022
0
PROJECT MANAGERS, PLANNERS, ARCHITECTS & CONSULTING ENGINEERS 23-2-2022 ISSUED FOR CONSTRUCTION AHSAN CHECKED/CO-ORDINATED
D-11/A, BLOCK NO-17, GULSHAN-E-IQBAL, KARACHI. P.H. 34820497 - 34982561 GULSHAN E MAYMAR KARACHI 0

DESCRIPTION REV. BY A.H.M A3


NO. DATE SHEET SIZE
01 02 03 04 05 06
4'-6" 7'-0" 7'-0" 4'-6" 10'-6"
SCHEDULE OF SLAB STEEL
Z #3@10"c/c
Y #3@9"c/c
X #3@8"c/c
W #3@6"c/c

EQ
W

EQ
X
10'-0"

S1 S1

X
S1

Z
X

W
W

B
S4
X

X
Z

Y
S3
10'-6"

S3 S2 Y S1
X

X
Y

S4

Y
A
W

SLAB REINFORCEMENT
ALL BEAM ARE 6"X18"
ALL SLABS ARE 5" THICK

CONSULTANT CLIENT PROJECT TITLE REVISION DESIGNED BY SCALE N.T.S CODE


A.H.M DRAWING NO. ST-WWBS-05
WORKERS WELFARE REHABILITATION/ RENOVATION SUB ENGINEERS DRAWN BY JOB NO. -
WWBS
atif nazar (pvt.) ltd. BOARD SINDH LABOUR SQUARE 1000 FLATS OFFICE
AHSAN DATE
REVISION
FEB-2022
0
PROJECT MANAGERS, PLANNERS, ARCHITECTS & CONSULTING ENGINEERS 23-2-2022 ISSUED FOR CONSTRUCTION AHSAN CHECKED/CO-ORDINATED
D-11/A, BLOCK NO-17, GULSHAN-E-IQBAL, KARACHI. P.H. 34820497 - 34982561 GULSHAN E MAYMAR KARACHI 0

DESCRIPTION REV. BY A.H.M A3


NO. DATE SHEET SIZE