Professional Documents
Culture Documents
02-HPVS - TH7195 - User Manual
02-HPVS - TH7195 - User Manual
02-HPVS - TH7195 - User Manual
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 1
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers
TH 7195
User's Manual
TABLE OF CONTENTS
1. OVERVIEW OF THE TH7195 USER'S MANUAL....................................................................... 2
1.1. CONTENTS .................................................................................................................................... 2
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
1.1. Contents
This manual explains how to install and use the TH7195 Power Supply.
The manual is divided into five chapters.
sans l’accord de THALES ELECTRON DEVICES.
F
Complementary information to be read on an other chapter or an
other document.
Note this information.
! To be read absolutely.
Protective earth
party without the prior consent of THALES ELECTRON DEVICES
WARNING :
The TH7195 is a High Voltage Power Supply. So that, as a rule, it
must not be powered when the outputs are disconnected. It is
essential that the usual precautions for measurements of high
voltages are taken to avoid the danger of electrocution of personnel.
2.1. Description
• The TH 7195 is a microprocessor controlled High Voltage Power Supply (HVPS),
designed to drive 7", 9" and 12" x-ray Image Intensifiers (XRII).
• It operates from a 24 V ± 10 % DC input source, with 350mA max current.
sans l’accord de THALES ELECTRON DEVICES.
• In TH7195-2, TH7195-3 and TH7195-4 versions, several ways are provided to control the
power supply and to adjust and switch between the XRII input fields (see chapter 3.3):
- Three Control Input 1, 2 and 3 can be used either to switch between several pre-set XRII
fields, or to control linearly the G1, G2 and G3 electrode voltages of the XRII,
- Three encoders can be used to adjust manually the G1, G2 and G3 voltages, for each
XRII field,
- A set of 5 switches can be used to select the different operating modes of the power
supply,
- A serial port interface can be used to take control of the power supply, to set G1, G2 and
G3 voltages, to select the XRII field, or to measure back the real electrode voltages (see
chapter 3.4).
• Seven test points are available, which provide a low voltage proportional to the five
electrode voltages, as well as to the photocathode and the getter currents (see chapter 3.5).
• TH7195 is designed for use with pulsed X-rays (maximum photocathode instantaneous
current : 50 µA with no significant loss of resolution on the XRII).
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
It can also be used for Industrial Non Destructive Controls. In such applications, be careful that
the TH7195 specification meets your specific requirements.
sans l’accord de THALES ELECTRON DEVICES.
2.5. Characteristics
EN 50082-2 : Electromagnetic compatibility - Generic immunity standard
Part 2 : Industrial environment
party without the prior consent of THALES ELECTRON DEVICES
2.4. CE label
The TH7195 power supply is in accordance with the essential requirements of the 89/336/CEE
directive for medical and industrial applications.
F
See technical specification for information on electrical and
mechanical characteristics, and on maximum ratings.
sans l’accord de THALES ELECTRON DEVICES.
ADC
DAC 20kV U3
+24V multiplier
Safety
Device*
ADC
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
DAC 30kV U5
multiplier U4
0V
party without the prior consent of THALES ELECTRON DEVICES
Microcontroler ADC U2
serial
bus
DAC
ADC U1
Uc1 ADC
GND
Uc2 ADC DAC
Uc3 ADC
3. OPERATING INSTRUCTIONS
F See outline drawing 8 323 940 of the technical specification for the
exact position of the slits.
TYPICAL CONFIGURATION
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers
A UE + 24V DC
G4 0VP -
G3 UC1,2,3 XRII field
G2 0V mode control
XRII G1 TH7195
PC
E Serial port
micro
GND 0V
sans l’accord de THALES ELECTRON DEVICES.
computer
Mode control and the micro-computer are optional, and depend on the equipment.
All inputs and outputs are protected against short cuts and light over voltages.
3.3. Adjustments
On the TH7195, U5 and U4 voltages are fixed, but U3, U2 and U1 voltages are adjustable in
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
ranges which depend on the version. The typical values of the ranges are given below :
* It is also possible to set U1 voltage to a value near zero, for quadruple-field XRII.
The TH7195-2, TH7195-3 and TH7195-4 versions enable the adjustment of U1, U2 and U3
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers
voltages in their respective ranges, to obtain the different input fields on the XRII.
This adjustment can be done through different ways, selected by internal switches on the side of
the power supply:
Configuration switches
OFF adjustment slots
sans l’accord de THALES ELECTRON DEVICES.
ON
G1 G2 G3
5 4 3 2 1
In this mode, up to 8 different fields of the XRII can be selected through the control voltage
inputs (pins 14, 6 and 13 of the input Sub-D connector). These inputs are TTL compatible
inputs, as below:
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1 (or none)
open or <0.7V >1.8V open or <0.7V Magnifying mode M2 (or none)
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
The 8 modes are fully equivalent, and each has its own set of U1, U2, U3 voltages.
In general case, only 1, 2, 3 or 4 fields are used, so the mode selection can be done with a
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers
UE + 24V DC
0VP -
MN
TH7195
M1
UC1 M2
UC2 M3
UC3
sans l’accord de THALES ELECTRON DEVICES.
To adjust the U1, U2, U3 voltages for each XRII magnifying mode (if applicable), follow the
description below:
- First, set the switch number 1 to OFF to unlock the voltages
- Select the chosen XRII magnifying mode via UC1, UC2, UC3 inputs (if applicable)
- Turn the adjustment slots G1, G2, G3 with a screwdriver, to adjust the respective U1, U2,
U3 voltages to the desired values.
- Repeat steps 2 and 3 for each desired XRII magnifying mode (if applicable)
- Finally, reset the switch number 1 to ON to lock the voltages
In this mode, U1, U2 and U3 output voltages are directly proportional to the input voltages
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
applied respectively to UC1, UC2 and UC3 control inputs, as indicated below:
F
This analogic mode is for compatibility with some existing
equipment only, and is not recommended for new equipment, as it
has not a high electromagnetic immunity.
Signal Description
TXD output (pin 3) Serial data sent from the TH7195
RXD input (pin 2) Serial data received by the TH7195
sans l’accord de THALES ELECTRON DEVICES.
DTR output (pin 9) Signal sent by the TH7195, indicating (when high) that it is
ready to receive data
CTS input (pin 10) Signal received by the TH7195, indicating (when high) that it
can send data
To select number of baud, switches 4 and 5 should be set as below, before power on :
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
4800 OFF ON
9600 ON OFF
19200 ON ON
To control the TH7195, the computer must send instructions, and the power supply will
eventually send an answer. Any instruction sent via the serial interface will be priority on the
configuration switches setting and the input signals state.
The valid instructions are described below, they are not case sensitive:
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers
Examples :
Answer to command « N ? » :
Format : xxxTH719y-v_zz[number]_/_[version]_/_[date]_/_[authors]_/_[factory]_[CRLF]
With :
• xxx are possible dummy characters that can happen in some cases when receiving the very
first message in a session.
sans l’accord de THALES ELECTRON DEVICES.
Answer to command « Un ? » :
* For n=1, sends back the U1 output voltage value, in volts, with « yyy.yy » format
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
Answer to command « T ? » :
Sends back 8 characters « xxxxxxxx » corresponding to the HVPS cumulated operating time, in
seconds (example : 12345678 = 12345678 sec = 3429 operating hours)
TH7198-x
Command Answer string description TH7195-x TH7197-x
TH7221-x
U3 ? X X X
back U3 output voltage value, in kilovolts.
Example: if the voltage between Tp3 and GND is 0.65 V, it means that U3 voltage is 6.5 kV ±
6%
1. - Set G3 : To adjust the size of the input image in accordance with the XRII magnifying
modes (if applicable), use the XRII test report to get the G3 value (G3 = U3),
2. - Set G2 : To adjust the focus electrode for the best center resolution (G2 = U2) use the
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
3. - Adjust G1 : Eventually, for the best center and border resolution (G1 = U1),
party without the prior consent of THALES ELECTRON DEVICES
4. - Reajust G3 : If necessary,
Remarks :
- For a slight change of size input, step 3 is not useful,
- U2 voltage (G2) is always the last adjustment to be done.
TH7195-1 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
sans l’accord de THALES ELECTRON DEVICES.
TH7195-2 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1
TH7195-3 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1
open or <0.7V >1.8V open or <0.7V Magnifying mode M2 (or none)
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property
TH7195-4 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
party without the prior consent of THALES ELECTRON DEVICES
4. TROUBLESHOOTING GUIDE
Checking these points enables to locate a possible operating failure. It is nevertheless
recommended to return the power supply to the factory for expertise in the case of any problem
and to avoid all interventions on the components.
Effect Action
sans l’accord de THALES ELECTRON DEVICES.
If yes :
3. Check the camera or XRII
It is impossible to 1. Check the position of configuration switches
adjust output 2. Follow instructions of chapter 3.
voltages
5. MAINTENANCE INFORMATION
The power supply includes electrostatic sensitive devices.
A protection as defined in CECC 00015/I must be used to protect
sensitive devices from ESD