THALES ELECTRON DEVICES 61 411 736 C

USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 1
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

Document Number : TIV/1M.1166/96 EM


sans l’accord de THALES ELECTRON DEVICES.

TH 7195
User's Manual

TABLE OF CONTENTS
1. OVERVIEW OF THE TH7195 USER'S MANUAL....................................................................... 2
1.1. CONTENTS .................................................................................................................................... 2
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

1.2. SYMBOLS USED ............................................................................................................................ 2


1.3. OPERATORS' SAFETY .................................................................................................................... 2
2. DESCRIPTION OF THE TH7195 POWER SUPPLY................................................................... 3
2.1. DESCRIPTION ................................................................................................................................ 3
2.2. DESIGNED APPLICATION ............................................................................................................... 4
party without the prior consent of THALES ELECTRON DEVICES

2.3. REFERENCE TO STANDARDS ......................................................................................................... 4


2.5. CHARACTERISTICS........................................................................................................................ 4
2.4. CE LABEL..................................................................................................................................... 5
2.6. BLOCK DIAGRAM .......................................................................................................................... 5
3. OPERATING INSTRUCTIONS ...................................................................................................... 6
3.1. MECHANICAL INTERFACE ............................................................................................................. 6
3.2. ELECTRICAL INTERFACE ............................................................................................................... 6
3.3. ADJUSTMENTS .............................................................................................................................. 7
3.4. SERIAL PORT............................................................................................................................... 10
3.6. TEST POINTS ............................................................................................................................... 14
3.7. PROCEDURE FOR SETTING UP A THALES XRII.......................................................................... 14
3.8. FACTORY SETTINGS .................................................................................................................... 15
4. TROUBLESHOOTING GUIDE .................................................................................................... 16
5. MAINTENANCE INFORMATION .............................................................................................. 16

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 2
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

1. OVERVIEW OF THE TH7195 USER'S MANUAL

1.1. Contents
This manual explains how to install and use the TH7195 Power Supply.
The manual is divided into five chapters.
sans l’accord de THALES ELECTRON DEVICES.

1.2. Symbols used

F
Complementary information to be read on an other chapter or an
other document.
Note this information.

! To be read absolutely.

To call attention to the risk of electrical shock. Care is required to


prevent personnel injury.

To call attention to the risk of electrostatic discharges. Care is


required to prevent damage on power supply.
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

Protective earth
party without the prior consent of THALES ELECTRON DEVICES

1.3. Operators' safety


For the correct and safe use of the TH7195 Power Supply, it is essential that the personnel
follows the safety precautions described in this manual.

WARNING :
The TH7195 is a High Voltage Power Supply. So that, as a rule, it
must not be powered when the outputs are disconnected. It is
essential that the usual precautions for measurements of high
voltages are taken to avoid the danger of electrocution of personnel.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 3
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

2. DESCRIPTION OF THE TH7195 POWER SUPPLY

2.1. Description
• The TH 7195 is a microprocessor controlled High Voltage Power Supply (HVPS),
designed to drive 7", 9" and 12" x-ray Image Intensifiers (XRII).
• It operates from a 24 V ± 10 % DC input source, with 350mA max current.
sans l’accord de THALES ELECTRON DEVICES.

• In TH7195-2, TH7195-3 and TH7195-4 versions, several ways are provided to control the
power supply and to adjust and switch between the XRII input fields (see chapter 3.3):
- Three Control Input 1, 2 and 3 can be used either to switch between several pre-set XRII
fields, or to control linearly the G1, G2 and G3 electrode voltages of the XRII,
- Three encoders can be used to adjust manually the G1, G2 and G3 voltages, for each
XRII field,
- A set of 5 switches can be used to select the different operating modes of the power
supply,
- A serial port interface can be used to take control of the power supply, to set G1, G2 and
G3 voltages, to select the XRII field, or to measure back the real electrode voltages (see
chapter 3.4).

• Seven test points are available, which provide a low voltage proportional to the five
electrode voltages, as well as to the photocathode and the getter currents (see chapter 3.5).
• TH7195 is designed for use with pulsed X-rays (maximum photocathode instantaneous
current : 50 µA with no significant loss of resolution on the XRII).
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

party without the prior consent of THALES ELECTRON DEVICES

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 4
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

2.2. Designed application


The TH7195 High Voltage Power Supply is designed for RADIOLOGICAL MEDICAL
APPLICATIONS.

It can also be used for Industrial Non Destructive Controls. In such applications, be careful that
the TH7195 specification meets your specific requirements.
sans l’accord de THALES ELECTRON DEVICES.

2.3. Reference to standards


The TH7195 meets the requirements of following standards:

IEC 601-1 : Medical electrical equipment


Part 1 : General requirements for safety

IEC 601-1-2 : Medical electrical equipment


Part 1 : General requirements for safety
Part 2 : Collateral standard : Electromagnetic compatibility -
Requirements and tests

EN 50081-1 : Electromagnetic compatibility - Generic emission standard


Part 1 : Residential, Commercial and Light Industrial environment
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

2.5. Characteristics
EN 50082-2 : Electromagnetic compatibility - Generic immunity standard
Part 2 : Industrial environment
party without the prior consent of THALES ELECTRON DEVICES

IEC 68 : Test methods applicable to equipment


General climatic and mechanical tests
General

UL 187 : Standard for safety


X-ray equipment

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 5
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

2.4. CE label
The TH7195 power supply is in accordance with the essential requirements of the 89/336/CEE
directive for medical and industrial applications.

F
See technical specification for information on electrical and
mechanical characteristics, and on maximum ratings.
sans l’accord de THALES ELECTRON DEVICES.

§ TS 4987-161 for TH7195-1


§ TS 4988-161 for TH7195-2
§ TS 4989-161 for TH7195-3
§ TS 4990-161 for TH7195-4

2.6. Block diagram


- Uc1, Uc2, Uc3 are the low voltages inputs, the serial bus is used for commands (RS232C)
- + 24 V and 0V are the power supply inputs
- GND, U1, U2, U3, U4, U5 are the high voltage outputs

ADC

DAC 20kV U3
+24V multiplier
Safety
Device*
ADC
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

DAC 30kV U5
multiplier U4

0V
party without the prior consent of THALES ELECTRON DEVICES

Microcontroler ADC U2
serial
bus
DAC

ADC U1
Uc1 ADC
GND
Uc2 ADC DAC
Uc3 ADC

(*) Voltage safety device : TRANZORB diode 1.5KE33 maximum voltage = 33 V


Current safety device : POLYSWITCH reset able fuse max. current = 750 mA
ADC = Analog to Digital Converter - DAC = Digital to Analog Converter

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 6
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

3. OPERATING INSTRUCTIONS

3.1. Mechanical interface


The approximate weight of the TH7195 power supply is 1.3 kg.
The TH7195 power supply has six slits on lateral braces to allow different ways for fixing.
sans l’accord de THALES ELECTRON DEVICES.

F See outline drawing 8 323 940 of the technical specification for the
exact position of the slits.

3.2. Electrical interface


Connection connector type voltage, current
symbols
power supply input (UE) pin 15 Ue, Ie
power 0 volt (0VP) pin 8 J 0VP
control input 1 (UC1) pin 14 Male Sub-D Uc1
control input 2 (UC2) pin 6 15 pins Uc2
control input 3 (UC3) pin 13 Uc3
0 volt (0V) pins 4,5,7 0V
Serial port:
reception input (RXD) pin 2
transmission output (TXD) pin 3
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

ready to receive output (DTR) pin 9


enable to send input (CTS) pin 10
0 volt (0V) pin 1 0V
do not use, leave open pin 11
party without the prior consent of THALES ELECTRON DEVICES

do not use, leave open pin 12


ANODE (A) for AMP LGH - 1 L 832 692/2 type cable U5
G4 electrode (G4) for AMP LGH - 1/2 L 840 706/2 type cable U4
G3 electrode (G3) for AMP LGH - 1/2 L 840 706/2 type cable U3
G2 electrode (G2) for AMP LGH - 1/2 L 840 706/2 type cable U2
G1 electrode (G1) for AMP LGH - 1/2 L 840 706/2 type cable U1
photocathode (PC) one 6.3mm FASTON lug Ipc
cathode of active getter (E) one 6.3mm FASTON lug Igetter
HT 0 volt and case ground (GND) one M4 screw 0VHT

0VP, 0V and GND are connected together internally

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 7

TYPICAL CONFIGURATION
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

A UE + 24V DC
G4 0VP -
G3 UC1,2,3 XRII field
G2 0V mode control
XRII G1 TH7195
PC
E Serial port
micro
GND 0V
sans l’accord de THALES ELECTRON DEVICES.

computer

Mode control and the micro-computer are optional, and depend on the equipment.
All inputs and outputs are protected against short cuts and light over voltages.

The continuity of the safety ground must always be maintained.

To prevent electrical shocks and personal injury, be sure there is no


damage on the sheath of the output cables.

3.3. Adjustments
On the TH7195, U5 and U4 voltages are fixed, but U3, U2 and U1 voltages are adjustable in
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

ranges which depend on the version. The typical values of the ranges are given below :

Parameter TH7195-1 TH7195-2 TH7195-3 TH7195-4 Unit


Voltage U5 30 30 30 30 kV
party without the prior consent of THALES ELECTRON DEVICES

Voltage U4 (with 250MΩ load) 2.6 2.6 2.6 2.6 kV


Voltage U3 max 5 8 13 20 kV
Voltage U3 min 2 2 2 2 kV
Voltage U2 max 1000 1000 1200 2000 V
Voltage U2 min 200 200 200 200 V
Voltage U1 max 350 350 350 350 V
Voltage U1 min* 35 35 35 35 V

* It is also possible to set U1 voltage to a value near zero, for quadruple-field XRII.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 8

The TH7195-2, TH7195-3 and TH7195-4 versions enable the adjustment of U1, U2 and U3
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

voltages in their respective ranges, to obtain the different input fields on the XRII.

This adjustment can be done through different ways, selected by internal switches on the side of
the power supply:

Configuration switches
OFF adjustment slots
sans l’accord de THALES ELECTRON DEVICES.

ON
G1 G2 G3
5 4 3 2 1

Switch 3 is reserved for future use and should always be OFF.

3.3.1. Standard XRII field mode control


This is selected when switch 2 is set to OFF (default) before power on.

In this mode, up to 8 different fields of the XRII can be selected through the control voltage
inputs (pins 14, 6 and 13 of the input Sub-D connector). These inputs are TTL compatible
inputs, as below:

Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1 (or none)
open or <0.7V >1.8V open or <0.7V Magnifying mode M2 (or none)
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

>1.8V >1.8V open or <0.7V Magnifying mode M3 (or none)


open or <0.7V open or <0.7V >1.8V Magnifying mode M4 (or M3 or none)
>1.8V open or <0.7V >1.8V Magnifying mode M5 (or none)
party without the prior consent of THALES ELECTRON DEVICES

open or <0.7V >1.8V >1.8V Magnifying mode M6 (or none)


>1.8V >1.8V >1.8V Magnifying mode M7 (or none)

The 8 modes are fully equivalent, and each has its own set of U1, U2, U3 voltages.

F See factory settings (chapter 3.7)

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 9

In general case, only 1, 2, 3 or 4 fields are used, so the mode selection can be done with a
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

simple switch connected as below:

UE + 24V DC
0VP -
MN
TH7195
M1
UC1 M2
UC2 M3
UC3
sans l’accord de THALES ELECTRON DEVICES.

To adjust the U1, U2, U3 voltages for each XRII magnifying mode (if applicable), follow the
description below:
- First, set the switch number 1 to OFF to unlock the voltages
- Select the chosen XRII magnifying mode via UC1, UC2, UC3 inputs (if applicable)
- Turn the adjustment slots G1, G2, G3 with a screwdriver, to adjust the respective U1, U2,
U3 voltages to the desired values.
- Repeat steps 2 and 3 for each desired XRII magnifying mode (if applicable)
- Finally, reset the switch number 1 to ON to lock the voltages

3.3.2. Analogic 0-10V control


This is selected when switch 2 is set to ON before power on.

In this mode, U1, U2 and U3 output voltages are directly proportional to the input voltages
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

applied respectively to UC1, UC2 and UC3 control inputs, as indicated below:

UC input voltage Output high voltage


party without the prior consent of THALES ELECTRON DEVICES

1V < Uc3 < 10V U3 = 2000 x Uc3


1V < Uc2 < 10V U2 = 200 x Uc2
1V < Uc1 < 10V U1 = 35 x Uc1
Uc1 < 0.2V 0V < U1 < 10V

F
This analogic mode is for compatibility with some existing
equipment only, and is not recommended for new equipment, as it
has not a high electromagnetic immunity.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 10
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

3.4. Serial port


This port is provided to control the TH7195 by a micro-computer or any other programmable
device. It consists in 4 signals described below:

Signal Description
TXD output (pin 3) Serial data sent from the TH7195
RXD input (pin 2) Serial data received by the TH7195
sans l’accord de THALES ELECTRON DEVICES.

DTR output (pin 9) Signal sent by the TH7195, indicating (when high) that it is
ready to receive data
CTS input (pin 10) Signal received by the TH7195, indicating (when high) that it
can send data

The characteristics of the serial port are the following :


- type: RS232C
- levels: high = +12V, low = -12V
- bauds: 2400 (default), 4800, 9600 or 19200
- word length: 8 bits
- parity: none
- stop bits: 1
- handshake: DTR/CTS only (not XON/XOFF)
- code: ASCII

To select number of baud, switches 4 and 5 should be set as below, before power on :
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

Number of bauds switch 4 switch 5


2400 (default) OFF OFF
party without the prior consent of THALES ELECTRON DEVICES

4800 OFF ON
9600 ON OFF
19200 ON ON

To control the TH7195, the computer must send instructions, and the power supply will
eventually send an answer. Any instruction sent via the serial interface will be priority on the
configuration switches setting and the input signals state.

Each instruction must be terminated with a LF, or CR LF.


When the powers supply gives an answer, it is terminated with a CR LF.
Decimal number with exponent notation are not allowed.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 11

The valid instructions are described below, they are not case sensitive:
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

Instruction Description Answer


Unv Sets the Un voltage of Gn electrode to v. None
n can be 1, 2 or 3.
if n = 1: 35.0 < v < 350.0 or v=0.0 v is in volts
if n = 2: 200.0 < v <2000.0 v is in volts
if n = 3: 2.0 < v < 20.0 v is in kV
Un? Asks for the actual Un voltage of Gn electrode. value v
sans l’accord de THALES ELECTRON DEVICES.

n can be 1, 2, 3, 4, 5 (anode on TH7195 and TH7197, if n = 1, 2 or 3 : v is in V


screen on TH7198 and TH7221), if n = 3, 5 or 6 : v is in kV
6 (anode on TH7198 and TH7221 only) ,
B (blanking voltage on TH7197 only)
UC Sets the U1, U2 and U3 voltage proportional to the none
Uc1, Uc2, Uc3 voltages, as described in chapter 3.2
Mn Selects the magnifying mode n none
n can be 0 (or N), 1, 2, 3, 4, 5, 6 or 7
MC Selects the magnifying mode with respect to UC1, none
UC2, UC3 inputs, as described in chapter 3.1
N? Asks for description string of the power supply string containing:
name and version of
HVPS
serial number of HVPS
software version and date
authors and company
T? Asks for total working time of power supply total working time in
seconds
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

Examples :

Instruction sent Answer Result


party without the prior consent of THALES ELECTRON DEVICES

U1200.0 none U1 voltage is set to 200 volts


U33.2 none U3 voltage is set to 3.2 kilovolts
U3? 3.200 U3 is measured to be 3.2 kilovolts
M2 none Magnifying mode 2 is selected
U1, U2 and U3 change to their pre-set values for mode
2
T? 15834 The HVPS has worked for 15834 seconds since first
power on

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 12
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

Answer to command « N ? » :
Format : xxxTH719y-v_zz[number]_/_[version]_/_[date]_/_[authors]_/_[factory]_[CRLF]
With :
• xxx are possible dummy characters that can happen in some cases when receiving the very
first message in a session.
sans l’accord de THALES ELECTRON DEVICES.

• TH719y is the generic HVPS name, with a possible revision index.


• -v is the HVPS version (actually represents the number of zoom modes).
• zz are the last 2 characters of the HVPS type (example : 95 for TH7195).
• [number] is the individual HVPS serial number.
• [version] is the software revision number, with x.y-zz format.
• [date] is the release date of the software version.
• [authors] is the HVPS designer names.
• [factory] is the manufacturing company name.
• [CRLF] is the CR/LF character sequence, i.e. ASCII codes 13,10.
• _ is a « space » character (ASCII code 32).
• / is the field delimiting character.
Example : cgbTH7195-3 9512345 / V1.2-30 / 06 Jun 1996 / Eric MARCHE & Alain
GIRARD / TTE TIV Moirans

Answer to command « Un ? » :

* For n=1, sends back the U1 output voltage value, in volts, with « yyy.yy » format
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

(example : 258.25 =>258.25 volts)


* For n=2, sends back the U2 output voltage value, in volts, with « yyyy.y » format
(example : 1258.2 =>1258.2 volts)
* For n=3, sends back the U3 output voltage value, in kilovolts, with « yy.yyy » format
party without the prior consent of THALES ELECTRON DEVICES

(example : 12.582 =>12.582 kilovolts)


* For n=4, sends back the U4 output voltage value, in volts, with « yyyy » format
(example : 2852 =>2852 volts)
* For n=5, sends back the U5 output voltage value, in kilovolts, with « yy.yy » format
(example : 29.92 =>29.92 kilovolts)
* For n=6, sends back the U6 output voltage value, in kilovolts, with « yy.yy » format
(example : 36.79 =>36.79 kilovolts)
* For n=B, sends back the blanking voltage value, in volts, with « yyyy » format
(example : 1005 =>1005 volts)

Answer to command « T ? » :

Sends back 8 characters « xxxxxxxx » corresponding to the HVPS cumulated operating time, in
seconds (example : 12345678 = 12345678 sec = 3429 operating hours)

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 13
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

TH7198-x
Command Answer string description TH7195-x TH7197-x
TH7221-x

N? General description. Variable size character


string. The 5 information fields are separated by
« _/_ ».
Present string length is 87 characters.
sans l’accord de THALES ELECTRON DEVICES.

Info field 1 : 16 characters :


HVPS family « TH719x (x=5 or 7 or 8) »
+ number of zoom modes –v (1≤x≤4) X X X
+ HVPS type _xx = (xx=95 or 97 or 98 or 21)
+ serial number xxxxx
Info field 2 : 7 characters :
Software version, format Vx.y-zz
Info field 3 : 11 characters
Software release date, format dd mmm yyyy
Info field 4 : 26 characters
HVPS designer names
Info field 5 : 15 characters
Manufacturing company name

Fixed point numeric string, format yyy.yy . Sends


U1 ? X X X
back U1 output voltage value, in volts.

Fixed point numeric string, format yyyy.y . Sends


U2 ? X X X
back U2 output voltage value, in volts.

Fixed point numeric string, format yy.yyy . Sends


of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

U3 ? X X X
back U3 output voltage value, in kilovolts.

Fixed point numeric string, format yyyy . Sends


U4 ? X X X
back U4 output voltage value, in volts.
party without the prior consent of THALES ELECTRON DEVICES

Fixed point numeric string, format yy.yy . Sends


U5 ? X X X
back U5 output voltage value, in kilovolts.

Fixed point numeric string, format yy.yy . Sends


U6 ? X
back U6 output voltage value, in kilovolts.

Fixed point numeric string, format yyyy . Sends


UB ? X
back blanking voltage value, in volts.

Numeric string. Sends back HVPS cumulated


T? X X X
operating time, in seconds.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 14
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

3.6. Test points


Seven test points enable a check of the output voltages and currents, by supplying proportional
voltages relative to GND. These voltages can be checked by any voltmeter with an input
impedance higher than or equal to 10 M? .

Test point Ratio Unit


TP1 relative to U1 0.01 ± 2% V/V
sans l’accord de THALES ELECTRON DEVICES.

TP2 relative to U2 1 ± 3% V/kV


TP3 relative to U3 0.1 ± 6% V/kV
TP4 relative to U4 1 ± 4% V/kV
TP5 relative to U5 0.1 ± 6% V/kV
TPE relative to Igetter 0.1 ± 2% V/µA
TPPC relative to Ipc not available

Example: if the voltage between Tp3 and GND is 0.65 V, it means that U3 voltage is 6.5 kV ±
6%

3.7. Procedure for setting up a THALES XRII


The procedure should not be necessary if the power supply is delivered with the tube

1. - Set G3 : To adjust the size of the input image in accordance with the XRII magnifying
modes (if applicable), use the XRII test report to get the G3 value (G3 = U3),

2. - Set G2 : To adjust the focus electrode for the best center resolution (G2 = U2) use the
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

XRII test report value as a starting point,

3. - Adjust G1 : Eventually, for the best center and border resolution (G1 = U1),
party without the prior consent of THALES ELECTRON DEVICES

4. - Reajust G3 : If necessary,

5. - Reajust G2 : For the best center resolution,

6. - Repeat steps 1 to 5 for each mode.

Remarks :
- For a slight change of size input, step 3 is not useful,
- U2 voltage (G2) is always the last adjustment to be done.

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 15
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

3.8. Factory settings


Values when the power supply is delivered with an XRII :

TH7195-1 :

Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
sans l’accord de THALES ELECTRON DEVICES.

open or <0.7V open or <0.7V open or <0.7V Normal mode MN

TH7195-2 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1

TH7195-3 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
open or <0.7V open or <0.7V open or <0.7V Normal mode MN
>1.8V open or <0.7V open or <0.7V Magnifying mode M1
open or <0.7V >1.8V open or <0.7V Magnifying mode M2 (or none)
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

TH7195-4 :
Uc1 (pin 14) Uc2 (pin 6) Uc3 (pin 13) XRII Fields
party without the prior consent of THALES ELECTRON DEVICES

open or <0.7V open or <0.7V open or <0.7V Normal mode MN


>1.8V open or <0.7V open or <0.7V Magnifying mode M1
open or <0.7V >1.8V open or <0.7V Magnifying mode M2
>1.8V >1.8V open or <0.7V Magnifying mode M3
open or <0.7V open or <0.7V >1.8V Magnifying mode M3

THALES ELECTRON DEVICES


SBU Tubes Intensificateurs d'Image et de Visualisation / SBU Image Tubes & Display
THALES ELECTRON DEVICES 61 411 736 C
USER'S
460 rue du Pommarin - ZI Centr'Alp
38430 Moirans - France MANUAL TH 7195
Tél : (+33) 04 76 57 40 00
Fax : (+33) 04 76 57 40 85 POWER SUPPLY April 2001 Page 16
Les informations contenues dans ce document sont la propriété exclusive de THALES
ELECTRON DEVICES et ne doivent pas être divulguées par le destinataire à des tiers

4. TROUBLESHOOTING GUIDE
Checking these points enables to locate a possible operating failure. It is nevertheless
recommended to return the power supply to the factory for expertise in the case of any problem
and to avoid all interventions on the components.

Effect Action
sans l’accord de THALES ELECTRON DEVICES.

There is no output 1. Check the output voltages on the test points


image on XRII If no output voltages, see below
If output voltages are OK
2. Check if the XRII is correctly focused (see the right voltage on the data sheet)
3. Check if there is a good electrical contact on the outputs of the power supply
If output voltages are not OK:
4. Follow instructions of chapter 3. to adjust XRII
There is no output 1. Check if the input voltage is in the limit of 24VDC ± 10%
voltage if yes :
2. Check if there is an input current on +24V of power supply
if OK :
3. Disconnect the High Voltage Power Supply and check the outputs are not
under short-circuit on the XRII
if no current :
4. An element of low voltage section is probably defective return the power
supply to the factory
There is an 1. Disconnect the High Voltage Power Supply and check the outputs are not
intermittent output under short-circuit on the XRII
voltage if not :
of THALES ELECTRON DEVICES and shall not be disclosed by the recipient to a third
All the information contained in this document remain the sole and exclusive property

2. Check if the 24VDC supply is not under current limitation


There is a poor 1. Check if the output voltages of selected mode are OK for the XRII
image resolution or If not :
incorrect image size 2. Adjust the output voltages (chapter 3.)
party without the prior consent of THALES ELECTRON DEVICES

If yes :
3. Check the camera or XRII
It is impossible to 1. Check the position of configuration switches
adjust output 2. Follow instructions of chapter 3.
voltages

5. MAINTENANCE INFORMATION
The power supply includes electrostatic sensitive devices.
A protection as defined in CECC 00015/I must be used to protect
sensitive devices from ESD

Maintenance of the power supply must be factory done.