Professional Documents
Culture Documents
Filters For Hydraulic and Lube Oil
Filters For Hydraulic and Lube Oil
Filters For Hydraulic and Lube Oil
Offshore / Marine
Special Order Filters Minimum order quantities and/or extended lead times will apply (consult HYDAC Product Management)
Low Pressure
RFM…S & RFM…Set - H2; RFMP - H8; RKT - H12; RKB - H24; RFT - H30; RFB - H46; RFLDH Welded - H54; AFLD API 614 - H64; SF - H74 H
High Pressure
DFFX - H80; HDF/HDFF - H88; HFDK4P - H92; HFDK3P - H96
*For specific details on each filter assembly, please refer to the “Quick Reference Guide” - Section A.
Filter Division
2260 City Line Road NOTE
Bethlehem, PA 18017 Information and related materials are subject to change without notice. This catalog, and all information
+1.610.266.0100 and related materials it contains, are provided “as is.” HYDAC makes no representation or warranty
Internet: www.hydac-na.com whatsoever regarding the completeness, accuracy, “up-to-dateness”, or adequacy of, the HYDAC-NA
Email: HYD.catalog@hydac-na.com domain and this catalog.
It seems that everyone is in the replacement element business, but “Buyer Beware!”. There are suppliers—pirates—
who have no concern for quality. Their mission is simply to capitalize on a brand’s reputation for quality engineering.
Pirates will offer rock bottom prices, but remember: design differences result in performance differences. Keep in
mind that “you get what you pay for”. Don’t end up paying the ultimate price – component failure, production down
time and costly repair - by using a cheap, imitation, low-performing element.
The housing pictured right shows evidence of competitor element failure—
bypass springs and pieces of the end cap in the outlet side. Application—
gearbox. Using Genuine HYDAC products is imperative for optimal
performance.
Identifying Genuine
HYDAC could
mean the difference
between
Stress
Success and Failure!
PN#02081318 / 07.19 / FIL1907-2109
QUICK REFERENCE
A
Quick Reference Guide
Quick Reference is an easy one-stop general selection guide. Broken down
by operating pressure (low, medium, high), filter type (inside-tank, in-tank,
inline, duplex, manifold-mount, etc.), maximum flow rate, port size, and flow
path; Quick Reference narrows down the selection into one or more filter
series suitable for the application. Catalog page numbers are also provided
so that the desired filter series data sheet can be found with ease.
360 350 RFL Cast Back Mount single filter with metric
3, 4 D
(25) (1325) page D145 threads.
(360 / 580) 343 RFLD Cast Back mounted duplex filter with metric
1-4 D
(25 / 40) (1300) page D149 threads. Ball valve changeover.
Mechanical
In-Tank 360 30 SF*** Mounts in-tank. Modified vacuum gauge
3/4 - 2 Bypass
Suction (25) (114) page H74 indicators are available.
In Element
**For a Set version of this filter, refer to Set Series section of the catalog. ***Special Order Filter. Refer to catalog information for details.
120 30 MF 160
1 1/4 - 1 1/2 S Standard length element.
(8.3) (113) page D54
5800 37 HFM
1 D In-line high pressure filter.
(400) (140) page F40
Betterfit® Elements
Description Types of Elements
HYDAC supplies a wide range of elements that are dimensionally • High efficiency depth filtration, pressure and return
interchangeable with elements of other manufacturers. Elements are • Surface filtration (wire mesh or paper) nominal, low pressure
of the same media and quality construction as HYDAC proprietary • Tank air-breather filters
elements. A list of available interchanges can be found under “Betterfit • Suction Strainers
Element Selector” at www.hydac-na.com.
Overview of Filters
Visit Us Online...
HYDAC’s web site, www.hydac-na.com, now offers our Online
Cross-Reference Guide to Betterfit® replacement elements titled
Betterfit Element Selector. With this user-friendly guide you
can match filter elements from many other manufacturers with
appropriate HYDAC Betafit® replacements.
No Wear
Some Wear
Heavy Wear
How Contaminants are Measured and How will these changes affect you?
Reported - Changes in the Industry In comparing the old standards to the new,
the following have not changed:
In hydraulic fluid power systems, power is transmitted and contained
through a liquid under pressure within an enclosed circuit. These • T
he amount and the size of solid contamination in your system is
fluids all contain a certain amount of solid particle contaminants. still the same!
The amount of particulate contaminants present in a hydraulic or • The filters still work the same way!
lubrication system’s fluid is commonly referred to as its cleanliness
level.
What has changed:
In 1999, the International Standards Organization (ISO) introduced
a series of new fluid cleanliness standards that reflect changes in The way particle size is specified has changed.
measuring and defining the cleanliness of fluid systems and the The new standards and reporting methods “move the measuring
way the size and amount of solid contaminants are reported. These stick” to correct for the inaccurate calibration assumptions made.
standards are summarized in Table 1.
mL Fluid
of changing the classification of the size of the particle. 17
15
Size Size
Table 2. A Comparison of Particle Size Classification 16
100Fluid
104 14
ISO 4402 (ACFTD) ISO 11171 (ISO MTD) 15
than Indicated
13
permL
< 1.0 µm 4.0 µm(c) 14
104
than Indicated
1.0 µm 4.2 µm(c)
12
per 100
13
11
of Particles
2 µm 4.6 µm(c)
103 12
3 µm 5.1 µm(c) 10
11
Greater
Particles
5 µm 6.4 µm(c) 103 9
10
8
Greater
10 µm 9.8 µm(c)
No. ofNo.
9
15 µm 13.6 µm(c) 102 7
8
20 µm 17.5 µm(c)
102 ISO
7
25 µm 21.2 µm(c) CODE
Previous Size per ISO 4402 Current Size per ISO 11171 ISO
1 2 5 10CODE15 20 30 40 50
Note that the size of the particles is reported differently; i.e., a particle Particle Size (micrometers)
1.0 µm in size under ISO 4402 is now considered to be 4.2 µm(c) in 1 2 5 10 15 20 30 40 50
size. Keep in mind that the particles are actually the same size Particle Size (micrometers)
they have always been; we are just using a different ruler.
ISO Scale Numbers - Figure 3(b). Graphing Particle Counts per ISO 4406:1999
ISO 4406 vs. ISO 4406:1999
ISO 4406:1999 provides guidelines for defining the level of 18
contamination present in a fluid sample in terms of an ISO rating. Due
to the change in the specification of particle sizes shown in Table 103 17
2, the definition of the ISO scale (or range) numbers needed to be 18
redefined. Tables 3(a) and 3(b) provide a comparison of ISO scale 103 16
17
mL Fluid
define an ISO rating. Under the old ISO 4406, the ISO scale numbers 15
than Indicated
Previous ISO codes are commonly made up of 2 scale numbers Current ISO codes are made up of 3 numbers representing the
representing the number of particles ≥5 µm and ≥15 µm. Showing number of particles ≥4 µm(c), ≥6 µm(c) and ≥14 µm(c). The particle
a third scale number, ≥2 µm is optional. The left number will always count is expressed as the number of particles per mL.
be larger. The scale numbers are defined such that each successive
scale is generally a doubling of the previous scale. The particle count
can be expressed as the number of particles per mL or per 100 mL,
but the ISO range numbers and the ISO codes do not change. xample Effects of Abrasion:
E
- Changes to tolerances
- Leakage
- Reduced efficiency
What types of wear are there?
- Particles produced in the
1. Abrasion caused by particles between
system create more wear!
reciprocating surfaces.
2. Erosion caused by particles and high fluid velocity. load
Solid Contamination
• pressure filters
• return line filters 17/15/12
• offline filtration loops
• oil transfer units for precleaning new oil
• portable and online contamination monitors
• reservoir breathers and filler/breathers
Water Content
• water content sensors 20/18/15
• reservoir breathers with silica gel desiccant
• vacuum dehydration water removal units
• water removal elements
Fluid Analysis
• bottle sampling kits
• complete analysis kits
23/21/18
Metered
MTD Slurry Test Filter
Downstream Upstream
Sample Sample
(ND > ) (NU > )
Pump
Invert Emulsions
Invert emulsions consist of a mixture of petroleum based oil and
water. Typical proportions are 60% oil to 40% water. Standard
HYDAC filters with 10 µm and 25 µm media elements are satisfactory
for use with these fluids. Filters should be sized conservatively for
invert emulsions. These fluids are non-Newtonian - their viscosity is
a function of shear. We recommend up to twice the normal element
area be used as space and other conditions permit.
Some special factors that need to be considered in the selection
process include the following:
• Potential
exists for cavitation problems with invert emulsions
similar to high water based fluids.
• Buna N or Viton seals are recommended, subject to manufacturer
stated compatibility.
Water Glycols
Water glycols consist of a mixture of water, glycol, and various
additives. HYDAC Betamicron® filter elements are compatible for use
with these fluids. Some special factors that need to be considered in
the selection process include the following:
• All aluminum in the filter should be water tolerant or anodized.
• Potential exists for cavitation problems with water glycols similar
to high water based fluids.
• Buna N or Viton seals are recommended, subject to manufacturer
stated compatibility.
TRANSDUCER
TRANSDUCER
components in the event of catastrophic failures. Systems with high
TRANSDUCER
intermittent return line flows may need only be sized to match the
output of the pump, where the return line may require a much larger
filter for the higher intermittent flows. See Figure 6(a).
Return line filtration: Return line filters are often considered
when initial cost is a major concern. A special concern in applying
return line filters is sizing for flow. Large rod cylinders and other
components can cause return line flows to be much greater than
pump output. Return lines can have substantial pressure surges, INPUT
INPUT
which need to be taken into consideration when selecting filters and INPUT
Pressure 1
1 GAL.
GAL.
Line 1 GAL.
Filter Return 10
10 GAL.
GAL.
Line 10 GAL.
Filter
a
a b
b
Air a b
Breather
Offline
Filters
1. Determining desired cleanliness level Step 1. Determine the most sensitive component in the system. Then, determine the desired
cleanliness level (ISO code) by using Tables 4 and 5 (in this Overview), review of component manuals or
by contacting the component manufacturer directly.
Operating pressure levels and system environmental conditions also have a bearing on cleanliness
requirements.
2. Selecting correct medium Step 2. Using Table 9 (in this Overview, respectively), identify the proper HYDAC filter media rating to
employ.
3. Where to filter Step 3. Determine where to locate the filters, using the information on “Filter Location” (Section 3, in
this Overview).
4. Selecting filter housing Step 4. Refer to Filter Products in the Table of Contents or the Quick Reference Guide and the
individual filter catalog pages to select the specific filter housing that will meet the requirements set
forth in Steps 2 and 3 above, as well as the pressure and flow parameters where the particular filter
will be located.
Consideration should also be given to installation convenience for your particular application. Use
the filter selection charts shown on the catalog pages to determine the specific filter model number
for the desired media rating at the required flow rate.
5. Selecting filter breather Step 5. For nonpressurized reservoirs, refer to the HYDAC Accessories Catalog to select the
appropriate filter breather.
6. Contamination control practices Step 6. Implement the appropriate manufacturing, assembly, and maintenance contamination
control procedures. Effective contamination control is achieved through the conscientious use
of sound manufacturing and maintenance practices. Some examples are: filtering make-up oil;
controlling contamination ingestion during manufacturing, assembly, maintenance, and repair
processes; and properly maintaining cylinder wiper seals.
7. Verifying results Step 7. Check all filtration systems to determine if the results expected are obtained and maintained
during system operation, as operating conditions and maintenance practices may not remain
constant. Take periodic fluid samples on a regular basis to monitor cleanliness, water content and
variations on amounts of wear metals. HYDAC distributors and field representatives have access
to contamination monitoring equipment that can determine the exact cleanliness level (ISO code) of
your system on the spot. Contact your HYDAC distributor or phone us for complete details.
To calculate a filter assembly ∆P we must first know the specifics of the application.
To calculate the ∆P across the housing we must know the flow rate and specific gravity of the fluid we wish to filter. A chart is provided in each of
the product pages that provides a curve outlining the pressure drop across the housing based upon the flow in GPM (gallons per minute). This data
must then be adjusted if the specific gravity is at a lower or higher point than the test Hydraulic Fluid (0.86). The formula for calculation of the
housing ∆P is shown as follows:
To calculate the ∆P across the element additional information is required. This will include the viscosity of the fluid (at operating temperature),
required filtration rating in µm (microns), type of element (High collapse -BH or Low collapse -BN), and K (coefficient) factor from the attached
conversion tables. With this information the following formula is used to calculate ∆P across the element. Again the specific gravity and
viscosity (standard hydraulic fluid figured at a viscosity of 141 SSU - Saybolt Universal Seconds - 30 centistrokes) will change the ∆P.
∆P Clean Element = Flow Rate GPM X Element K factor x Actual Specific Gravity x Actual Viscosity in SSU
or (∆P from element curve) 0.86 141
HOUSING
∆P Housing = ∆P Calculation (From Curve in catalog) x Actual Specific Gravity
0.86
∆P Housing = 1.5 psid x 0.86 = 1.5 psid
0.86
ELEMENT
FILTER ASSEMBLY
∆P Filter Assembly = ∆P Housing + ∆P Clean Element Clean assembly ∆P is less than 10 – 15 psid per “Typical Targets”
P Filter Assembly = 1.5 psid + 5.25 psid = 6.75 psid on Table 9 (in this Overview)
NOTE:
A change in the fluid can make a significant difference in the pressure drop across a filter assembly. A second calculation for the
element (∆P) should be done at the lowest temperature condition (cold start) to determine how the filter will operate under these
severe conditions with significantly higher viscosity.
See the next page for Cold Start Calculation.
HOUSING
∆P Housing = ∆P Calculation (From Curve in catalog) x Actual Specific Gravity
0.86
∆P Housing = 1.5 psid x 0.86 or (1.0) = 1.5 psid
0.86
ELEMENT
FILTER ASSEMBLY
∆P Filter Assembly = ∆P Housing + ∆P Clean Element
P Filter Assembly = 1.5 psid + 50.40 psid = 51.90 psid (Almost 8 times normal clean assembly ∆P)
NOTE:
When the element is partially loaded with some contamination and the system is cold started, the indicator may trip or possibly go
into bypass, until the fluids in the system warm up. This information is relative and important for our customers to understand as
they operate their systems under diverse conditions. This additional performance data helps our customers to define their system
operating procedures, assist in component selection and finalize design.
4. Make sure that the port size is large enough to handle the flow
2. Check pressure drop at maximum flow (especially when cylinders are used)
If pressure drop at maximum flow is >50% of indicator trip pressure use one size larger.
Check again if pressure drop is now <50%.
4. Make sure that the port size is large enough to handle the flow
*Company:___________________________________________________________________ *Email:_________________________________________________________________
Inlet/Outlet Configuration
(i.e. inline, side inlet/bottom outlet)
Overview of Elements
2. Integrated
drainage layer
6. Upstream
protective layer
Features
• U
nique HELIOS pleat geometry – optimizes media area open to
flow to calm the flow in areas between pleats reducing ΔP.
• Outer wrap perforations insure optimized flow onto the filter
pleats and help to minimize pressure losses.
• Outer wrap perforations also help to distribute the fluid incidence
stresses evenly in the axial and radial directions and thus
increase tear resistance.
Model Codes Containing Red are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
20 µm
1000
400
200
100
10
Example:
Filtration rate:
10 µm ß10 (c) = 400
1
0 2 4 6 8 10 12 14 16 18 20 22
Features
• API 614 compliant
• Glass fiber media, single-layer with support
• Innovative outer wrap with increased strength & better diffuser
effect = homogenous flow
• Integrated Stat-Free® technology
• Low collapse only - 145 psid (10 bar)
5. F
inal active depth layer to
remove fine particles
7. D
iffusion layer to equalize flow
across surface
8. O
uter screen to stabilize pleats
(under cover)
9. M
ulti-protection cover (for high
pressure elements)
can result.
• Improved performance (optimized Beta efficiency, contamination 1000
retention, ∆P/Q characteristics and Beta stability) and lowered weight
due to plastic spiral lock seam support tubes.
• All plastic end caps and support tubes are carbon impregnated 200
to conduct electricity, which ensures that static electricity will not 100
be generated to levels high enough to arc.
• Element outer wraps are made of plastic (polyester) to reduce
environment a impact and improve fatigue resistance. 10
• Zinc-free construction prevents zinc soaping.
1
0 2 4 6 8 10 12 14 16 18 20 22
Particle size (µm)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Technical Specifications
Collapse Pressure Rating 145 psid/10 bar
Temperature range: 32°F to 160°F (0°C to 71°C)
Compatibility with
Test criteria to ISO 2943
hydraulic media
High fatigue resistance due to solid
Flow fatigue resistance filter material supports on both sides
to ISO 3724 and high inherent stability of the filter
materials.
Opening pressure
∆P0 = 43 psid + 10% (3 bar + 10%)
of bypass valve
Element Construction
1. Bypass Valve with Metal Spring (can be easily removed when crushed)
2. Plastic Endcap
4. Fiberglass Media
5. P
lastic Outer Wrap
Features
• U
nique filter media has a very low resistance to fluid flow – thus,
reducing element ΔP.
• Synthetic fiber media, multi-layered with support
• Low collapse – 10 bar (145 psid)
• For use in HYDAC RF, RFD, RFL, RFLD, RFM, RKM, MFX Filters
1000
200
100
10
1
0 2 4 6 8 10 12 14 16 18 20 22
Particle size (µm)
Autospec HF4
5.03.XXDXXW
Wire Mesh
Size 25, 50, 100, 200 µm Wgt. (lbs.)
5.03.09DXXW 0.007 1.71
5.03.18DXXW 0.004 3.29
5.03.27DXXW 0.002 N/A*
Autospec HF3 1.11.08DXXBN (Low Collapse) Autospec HF3 1.11.08DXXBH (High Collapse)
Size 3 µm 5 µm 10 µm 20 µm Wgt. (lbs.) Size 3 µm 5 µm 10 µm 20 µm Wgt. (lbs.)
1.11.04DXXBN 0.590 0.500 0.266 0.153 0.69 1.11.04DXXBH 0.937 0.660 0.401 0.210 1.83
1.11.08DXXBN 0.289 0.241 0.135 0.076 1.02 1.11.08DXXBH 0.460 0.321 0.195 0.102 2.61
1.11.13DXXBN 0.175 0.146 0.082 0.046 1.51 1.11.13DXXBH 0.274 0.193 0.117 0.615 3.64
1.11.16DXXBN 0.132 0.110 0.062 0.035 1.89 1.11.16DXXBH 0.206 0.145 0.089 0.046 4.66
Autospec HF2 1.07.08DXXBN (Low Collapse) Autospec HF2 1.07.08DXXBH (High Collapse)
Size 3 µm 5 µm 10 µm 20 µm Wgt. (lbs.) Size 3 µm 5 µm 10 µm 20 µm Wgt. (lbs.)
1.07.04DXXBN 2.046 1.735 0.925 0.531 0.26 1.07.04DXXBH 2.400 1.690 1.027 0.538 0.51
1.07.08DXXBN 0.975 0.815 0.457 0.257 0.39 1.07.08DXXBH 1.165 0.820 0.499 0.262 0.85
* Not Available at the time of publication. Please contact HYDAC for latest information.
All Element K Factors in psi / gpm.
* Not Available at the time of publication. Please contact HYDAC for latest information.
All Element K Factors in psi / gpm.
* Not Available at the time of publication. Please contact HYDAC for latest information.
All Element K Factors in psi / gpm.
Spin-on …MA…P
Size 3 µm 10 µm 25 µm Wgt. (lbs.)
0040 MA XXX P 7.763 2.348 1.516 0.6
0080 MA XXX P 1.606 0.486 0.314 1.08
0085 MA XXX P 1.161 0.351 0.227 1.42
0090 MA XXX P 1.594 0.482 0.311 1.29
0095 MA XXX P 0.894 0.270 0.174 1.47
0160 MA XXX P 0.839 0.192 0.145 2.15
0180 MA XXX P 0.443 0.134 0.087 2.68
Spin-on …MA…AM
Size 10 µm 40 µm Wgt. (lbs.)
0080 MA XXX AM 0.513 N/A* 1.35
0085 MA XXX AM N/A* N/A* N/A*
0090 MA XXX AM 0.507 N/A* 1.50
0095 MA XXX AM 0.284 N/A* 2.00
0160 MA XXX AM N/A* 0.233 2.50
0180 MA XXX AM N/A* 0.136 3.60
* Not Available at the time of publication. Please contact HYDAC for latest information.
All Element K Factors in psi / gpm.
ΔP in bar
ΔP in psi
ΔP in psi
4.5 80
60
4.5
60
40 3.0
40 3.0
20 1.5 1.5
20
0 0 0 0
0 3 6 9 12 15 0 10 20 30 40 50
Q (gpm) Q (gpm)
60 60 4.0
4.0
50 50
3.0 3.0
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
40 40
30 2.0 30 2.0
20 20
1.0 1.0
10 10
0 0 0 0
0 10 20 30 40 50 0 20 40 60 80 100 120
Q (gpm) Q (gpm)
ΔP in bar
ΔP in psi
ΔP in psi
3.0
30 2.0 40
20 2.0
1.0 20
10 1.0
0 0 0 0
0 20 40 60 80 100 120 140 0 40 80 120 160 200
Q (gpm) Q (gpm)
B
Technical Specifications
Mounting Method 4 Mounting holes - filter housing
Port Connections Inlet / Outlet
30 ½” Threaded / 0.71” Dia Smooth
60/110 SAE-12 / SAE-12; 3/4” NPT / SAE-12
160/240 SAE-20 / SAE-20; 1 1/4” NPT
(with adapter) / SAE-20
330 SAE-20 / 2” NPT (with flange port adapter)
2” Threaded (NPT/BSPP/SAE) / same as inlet
2” SAE Flange, Code 61 / 2” NPT
Features 660 3” SAE Flange, Code 61 / 3” NPT
3” SAE Flange, Code 61 /
• RF 30 filters are constructed of polyamide plastic. 3” SAE Flange, Code 61
• RF 60 - 330 filters are constructed of aluminum material. 950 3-1/2” SAE Flange, Code 61 /
Aluminum alloy is water tolerant - anodization is not required for 3-1/2” SAE Flange, Code 61
high water based fluids (HWBF). 1300 4” SAE Flange, Code 61 /
• RF 660 - 1300 filters are constructed of ductile iron. 4” SAE Flange, Code 61
• Non-welded housing design reduces stress concentrations and Direction of Flow Inlet: Side Outlet: bottom
prevents fatigue failure. Materials of Construction
• Inlet/outlet port options include NPT, SAE straight thread O-ring Housing Lid
boss, and SAE 4-bolt flange to allow easy installation without 30 Polyamide Polyamide
costly adapters. 60-330 Aluminum Aluminum
• O -ring seals are used to provide positive, reliable sealing. Choice 660-1300 Ductile Iron Ductile Iron
of O-ring materials (nitrile rubber, fluorocarbon elastomer,
Flow Capacity
ethylene propylene rubber) provides compatibility with petroleum
oils, synthetic fluids, water-glycols, oil/water emulsions, and high 30 8 gpm (30 lpm)
water base fluids. 60 16 gpm (60 lpm)
110 29 gpm (110 lpm)
• Bolt-on lid requires minimal clearance for removal.
160 42 gpm (160 lpm)
• Reusable contamination basket prevents loss of retained 240 63 gpm (240 lpm)
contaminants into the reservoir during element replacement. 330 87 gpm (330 lpm)
• Single piece casting provides rigidity for inline or in-tank 660 174 gpm (660 lpm)
mounting. 950 251 gpm (950 lpm)
Note: This filter is configured with an ..... R .... type (return/low pressure) 1300 343 gpm (1300 lpm)
element, so if the filter requires a bypass, the bypass is located in the Housing Pressure Rating
closed end cap of the cartridge element.
Max. Allowable
Working Pressure* 360 psi (25 bar); (size 30 - 145 psi, 10 bar)
Fatigue Pressure 478 psi (33 bar) @ 700,000 cycles;
Burst Pressure 30 580 psi (40 bar)
60/110 1080 psi (75 bar)
Applications 160/240 1230 psi (85 bar)
330 1440 psi (100 bar)
660-1300 3045 psi (210 bar)
Element Collapse Pressure Rating
ON, W/HC, 290 psid (20 bar)
ECON2, BN4AM, P/HC, AM 145 psid (10 bar)
V 435 psid (30 bar)
Agricultural Industrial Construction Gearboxes Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Automotive Steel / Heavy Indicator Trip Pressure
Industry P = 29 psi (2 bar) -10% (standard)
P = 72 psi (5 bar) -10% (optional)
Bypass Valve Cracking Pressure
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10% (optional)
*Note: All RF Filters MAWP reduce to 7 bar (101.5 psi) when using the following
“VMF” and “VR” indicators: B, BM, E, ES, GC, LE, LZ.
1.69
1.5 43
38 Breather
[3.54]
90
Clearance
required
for element
removal Static
Indicator port
G 1/2"
1.06
3.39 27
86
Front View
OUTLET PORT
[0.71]
18
ID Smooth
[0.2] 0.394
5 10
(Uses M4 bolt)
4 Places
1.693
43
[2.36]
[3.07] 60
78 Tank opening
Mounting Pattern
Size 30
Weight (lbs.) 0.9
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
RF60/110
[3.78]
96
RF160/240
4.96
126
RF60/110
RF60/110 [3.23]
[2.17] 82
55 RF160/240
4.33
RF160 RF240 110
[2.83] [2.83]
72 72
[1.13]
RF 60/110 28.7
Adapter
[1.38] (For NPT Filters)
RF160/240 35.1 RF 60/110 3/4" NPT (2054390)
RF 160/240 11/4" NPT (2054389) RF60 RF110 RF160 RF240
[3.15] [5.71] [4.72] [7.09]
80 145 120 180
Clearance required for element
removal
Static indicator port
G 1/2"
INLET
RF60/110 RF60/110
3/4" Threaded RF60
[3.94] [6.54]
SF160/240
1 1/4" Threaded 100 166
RF160/240 RF110
[4.72] [9.17]
120 233
RF160
RF60/110
[8.23]
[1.73] RF60 RF110
[2.60] [5.24] 209
44
66 133 RF240
RF160/240
[10.63]
[2.13]
RF160 RF240 270
54 [3.50] [5.91]
89 150
OUTLET
RF60/110
3/4" Threaded
RF160/240
1 1/4" Threaded
D3
4 Places
Mounting Pattern
3.646
6.30 92.6 6.60
160 167.6
2.48
5.59 1.69
63
142 42.9
11.06 11.06
281 281
2.48
63 1.06 5.47
5.47 1/2-13UNC X 27 DP 139
139 4 Places
5.91
150
6.30
160
6.69 3.35
0.35
170 9 85
Uses M8 Bolts
INLET
2 1/2-12UN-2B Static
SAE-32 Indicator
Port
5.31 G 1/2"
135 2.48
63
Mounting Pattern
11.06
281
5.47
139
OUTLET
2" NPT
Size 330
Weight (lbs.) 9.0
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
8.465
215
4.33
110
INLET
Static [12.6]
Indicator Port 4.19 320
G 1/2" 106.4 Clearance
required for
element removal
2.44
61.9
3.27
83 8.31
3" SAE 211
Flange
Code 61
17.99
457
1.10
5/8"-11UNC-2B X 28 DP 9.69 G 1/2"
4 Places 246 ∆P Indicator
Port - "DE"
Option
6.54 5.43
166 138
9.65
245.1
3" NPT
OUTLET
0.55
14
(Uses M12 Bolts)
2.44
61.9 4.19
106.4
0.71
5/8"-11UNC-2B X 18 DP 8.66
4 Places 220
Mounting Pattern
OUTLET
3" SAE
Flange BOTTOM VIEW
Code 61 RF..660DM
Size 660
Weight (lbs.) 68.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
9.84
250
RF950:
[15.16]
RF950 385
5.31 RF1300:
[19.09]
135 485
RF1300 Clearance
[5.71] required for
145 element removal
INLET
RF950:
RF950:
4.75 9.17
Static Indicator Port 120.7 233
G 1/2" RF1300: RF1300:
[5.13] [10.91]
130.2 277
0.79
RF950: 5/8"-11UNC-2B X 20 DP
4 Places RF950:
3.66
1.1 93
RF1300: 5/8"-11UNC-2B X 28 DP RF1300:
4 Places [4.76] RF950:
121 19.11
RF950: 485.5
3 1/2" SAE Flange Code 61 RF1300:
RF1300: RF950:
[23.92]
4" SAE Flange Code 61 [9.92]
607.5
140
RF950: RF1300:
2.75 [13.02]
69.9 330
RF1300:
[3.06]
77.8 7.64 5.94
194 151
OUTLET G 1/2"
∆P Indicator 10.94
Port - "DE" 277.9
Option
RF950:
RF950:
2.75
3 1/2" SAE Flange Code 61
RF1300: 69.9
11.42 0.71
4" SAE Flange Code 61 RF1300:
290 18
[3.06]
Uses
77.8
M16
Bolts
RF950:
4.75 8.19
120.7 208
RF1300: 0.79
[5.13] 5/8"-11UNC-2B X 20 DP
130.2 4 Places Mounting Pattern
0 0 0 0
0 1 2 3 4 5 6 7 8 0 5 10 15 20 25 30
Q in gpm Q in gpm
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0030 R XXX ON 4.928 3.754 2.409 1.471 0.922 0.807
0060 R XXX ON 2.59 1.295 0.944 0.539 0.494 0.376
0110 R XXX ON 1.224 0.719 0.487 0.296 0.234 0.178
0160 R XXX ON 0.878 0.439 0.312 0.177 0.148 0.182
0240 R XXX ON 0.571 0.284 0.201 0.125 0.101 0.077
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0660 R XXX ON 0.196 0.093 0.066 0.037 0.031 0.025
0950 R XXX ON 0.131 0.057 0.043 0.026 0.021 0.017
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0160 R XXX ECON2 0.521 0.324 0.209 0.159
0240 R XXX ECON2 0.340 0.209 0.143 0.099
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0660 R XXX ECON2 0.104 0.066 0.044 0.027
0950 R XXX ECON2 0.066 0.044 0.027 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
B1 B2
B4
B1
B3
RFD 110: 1.00
25.4
RFD 240: L
Adapter NPT Inlet
[1.57]
39.8 H4
Adapter SAE Inlet Clearance
[1.31] required for
33.3 Static Indicator element
G 1/2" removal
2 places
H5
H3
H2
INLET
RFD 110: 1 1/16"-12UN-2B
SAE-12
or Size 110 240
3/4" NPT w/ adapter H1 [3.77] [4.96]
B1
PN (2700529) 96 126
RFD 240: 1 5/16"-12UN-2B [10.26] [13.2]
B2
SAE-16 260.5 335.5
or [1.87] [2.22]
1" NPT w/ adapter B3
47.5 56.5
PN (2701261)
OUTLET OUTLET [14] [18.14]
B4
RFD 110: 1 1/16"-12UN-2B RFD 110: 1 1/16"-12UN-2B 357 461
SAE-12 SAE-12 [3.15] [4.17]
RFD 240: G-1-1/4" female RFD 240: G-1-1/4" female D1
80 106
[3.9] [5.3]
D2
100 135
[0.315] [0.374]
D3
8 9.5
[5.24] [5.91]
H1
B2 133 150
D3 [3.46] [4.25]
H2
88 108
[1.73] [2.13]
H3
44 54
D1 [5.71] [7.1]
Tank H4
145 180
D2 Cut-out
[3.62] [3.74]
H5
92 95
[6.81] [6.81]
L
Mounting Pattern 173 173
Reservoir
M5 M6
bolts
Static
indicator port
G 1/2"
2 places
5.91
150
9.02
229
15.91 [7.09]
404 180
Clearance required
Static Indicator 3.06 for element removal
Port G1/2" 77.8 4.33
2 places 110
1.69
42.9
5.12
130
INLET
SAE DN 51
Flange 7.95 5.47
202 139
0.39
10 10
Use bolts 254
M8
5.31
6.69 135
170 Tank
Cut-out
Mounting Pattern
Size 330
Weight (lbs.) 29.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Static
indicator port
B4 G 1/2"
2 places
B1
B3
to
flange face L
H2
B7 INLET
H3
D8 Size 660 950 1300
H1
B1 [8.27] 210 [9.61] 244 [9.61] 244
6.54 B2 [12.99] 330 [15.35] 390 [16.14] 410
166
B3 [3.9] 100 [5.51] 140 [5.51] 140
B4 [21.26] 540 [25.2] 640 [25.98] 660
B5 [4.19] 106.5 [5.13] 130.2 [5.13] 130.2
OUTLET OUTLET
B6 [4.19] 106.4 [4.75] 120.7 [5.13] 130.2
B7 [2.43] 61.9 [3.06] 77.8 [3.06] 77.8
B6
B8 [2.43] 61.9 [2.75] 69.9 [3.06] 77.8
B9 [7.68] 195 [9.84] 250 [9.84] 250
D1 [7.1] 180 [8.19] 208 [8.19] 208
B9 D2 [8.66] 220 [11.42] 290 [11.42] 290
Mounting Flange D3 [0.55] 14 [0.71] 18 [0.63] 16
SAE DN 76 SAE DN 102 SAE DN 102
B8 D6
Flange Flange Flange
3” BSPP or
D9 D7 D7 SAE DN 76 SAE DN 89 SAE DN 102
Flange
D8 M16 x 2* M16 x 2* M16 x 2*
B2 M16 X 2, M16 X 2, M16 X 2,
D9
18 mm deep 20 mm deep 20 mm deep
D1
Tank H1 [9.68] 246 [9.94] 252.5 [13.01] 330.5
D3 Cut-Out H2 [7.99] 203 [8.85] 225 [10.6] 269
H3 [3.27] 83 [[3.66] 93 [4.76] 121
H4 [12.6] 320 [15.16] 385 [19.09] 485
H5 [4.48] 114 [6.69] 170 [6.69] 170
L [9.02] 229 [12.52] 318 [12.52] 318
Bolts** M12 x 1.75 M16 x 2 M16 x 2
D2
*Bolts included
** Recommended reservoir mounting bolts
Mounting Pattern
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0110 R XXX ON 1.224 0.719 0.487 0.296 0.234 0.178
0240 R XXX ON 0.571 0.284 0.201 0.125 0.101 0.077
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0660 R XXX ON 0.196 0.093 0.066 0.037 0.031 0.025
0950 R XXX ON 0.131 0.057 0.043 0.026 0.021 0.017
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0240 R XXX ECON2 0.340 0.209 0.143 0.099
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0660 R XXX ECON2 0.104 0.066 0.044 0.027
0950 R XXX ECON2 0.066 0.044 0.027 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
Technical Specifications
Mounting Method
75/90/150/165/185 2 mounting holes - filter
housing
2.0
Additional
Port
1.0
Primary INLET
2.0
Standard
RFM 90/150/-4L
2.0
1.0
3.0
Special
3.0
Special
3.35
85
1.83
46.5
1.00
25.4
Hex
3.03
77
[9.37]
238
Clearance required
for element removal 2.0 position G1/8"
Static indicator
port
2.0 position
G 1/8" Static
indicator port
1.0 position
Inlet
2.85
72.4
INLET
3/4"-16
SAE-8 11.72 1.02
297.7 25.9
2.16
55 8.87
225.3
0.76 OUTLET
19.2 I.D.
0.90
22.8 O.D.
3.07
78
bolt circle 0.24
6
4 places
Tank Cutout
2.34
59.5
Mounting Pattern
Size 50
Weight (lbs.) 1.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
1.06
27
2.72
69
5.45
138.5
[5.91]
RFM 75: 150
[9.06]
RFM 165: 230
[11.81]
RFM185: 300
G1/8" Clearance required
Static indicator for element removal
port INLET
Standard 1.0 1 5/16-12
postion SAE-16 port
1.34
34 3.19
81
G 1/8" Satic
Indicator ports
(optional cast
closed) [4.80]
6 places Oil separator 1.89 RFM 75: 122
[On Breather 48
Version] 8.11
RFM 165: 206
[10.71]
2.89 RFM185: 272
73.5
[Top of Bowl]
OUTLET 1.26
32
1.5 I.D.
38 O.D.
3.32
84.3
3.46
3.07 88
78 Tank Opening
Tank Opening w/ breather &
without breather & oil separator
oil separator
0.43
11
4.43
112.5
Mounting Pattern
1.06
27
4.33
110
2.76
70
5.53
140.3
[5.91]
G1/8" RFM 75: 150
Option [9.06]
Static indicator RFM 165: 230
port [11.8]
RFM185: 300
4.37 2.76 Clearance required
111 70 for element removal
1.19 3.19
30.3 81
3.30
83.7
G 1/8" Static
Indicator Ports
2 places
G 1/4"
[4.80] [7.99] INLET
Breather port
RFM 75: 203 1 5/16-12
RFM 75: 122
SAE-16 port
[8.11] [11.29]
RFM 165: 206 RFM 165: 287
[10.71] [10.71] 2.36
RFM 185: 272 RFM 185: 353 60
OUTLET 1.5
38 O.D.
1.26
2.89
32 I.D.
73.5
[Top of Bowl]
4.33
110
Tank Cutout
3.07
2.76 78
7.04 70
178.8
Mounting Pattern
Note: Breather (BF10
With Anti Splash)
INLET 1.06
1 5/16-12 27
SAE-16 port 4.88
(optional)
124
[5.91]
RFM 75: 150
[9.06]
RFM 165: 230 G1/8" 7.4
[11.81] Option
RFM185: 300 188
Static
Clearance required indicator G 1/4"
INLET port 2.93 Breather
for element removal
1 5/16-12 74.5 port
SAE-16 port 1.57 3.19
40 81
1.34
34 3.19
1.0
G1/8" 81
Option
Static
indicator
port
[4.80]
RFM 75: 122
[8.11]
RFM 165: 206
[10.71]
RFM 185: 272
1.26
2.89
32
73.5
I.D.
OUTLET Top of Bowl
1.5
38 0.35
O.D. 9
4 places
4.96
126
Bolt circle
3.07
78
Tank
opening
Mounting Pattern
1.8 2.56
Tank breather 45.6 65
(Optional) Without breather With breather
2.22
56.5
4.37
111
[8.46]
RFM 90: 215
[11.81]
RFM 150: 300
Clearance required
for element removal
1 1/16"-12UN
SAE-12 Port
INLET 0.55 1.22
14 31 3.11
79
G1/8"
Static indicator
port
2.36
60
Top of bowl
6.57
RFM 90: 167
[9.84]
RFM 150: 250
OUTLET
(Hose barb)
O.D. [0.98]
25
Mounting Pattern
Size 90 150
Weight (lbs.) 1.2 1.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
2.56
65
2.22
56.5
[8.46]
RFM 90: 215
[11.81]
RFM 150: 300
Clearance required
for element removal
G 1/8"
Static Indicator
port
2 Places
3.11
79
1-1/16"-12UN 1.22
SAE -12 Port
0.55 [9.69] 31
INLET
14 RFM 90: 246
12.95
RFM 150: 329
[6.57]
RFM 90: 167
9.84
RFM 150: 250
2.36
60
Top of Bowl
OUTLET
(Hose Barb)
O.D. [0.98]
25 0.33
8.5
3.54
4 Places
88
Bolt Circle
Tank Cutout
2.52
64
Mounting Pattern
Size 90 150
Weight (lbs.) 1.2 1.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
1.42
36
6.1
6.79
155
172.5
3.74
95
INLET 13.68
1 7/8"-12UN 1.38 RFM 210: 348
SAE-24 Port 35 [18.89]
RFM270: 480
0.43
11
9.9
RFM 210: 252 3.94
[15.12] 100
RFM270: 384
[1.34]
34
Open bottom
OUTLET
6.69 0.43
170 11
bolt circle 4 places
4.13
105
Tank
opening Mounting Pattern
8.27
210
6.1
155
7.28
185
10.32
RFM 330: 262.1
[13.51]
RFM500: 343.1
2
4.81 50.7
122.2 1-7/8"-12UN 6.26
SAE-24 Port RFM 330: 159
Top of Bowl
INLET or [9.45]
1 1/2" SAE Flange- RFM500: 240
Code 61 Port
2" NPT
OUTLET
0.43
11
6.99 4 places
2.75 177.5
69.9 Bolt circle
Tank Opening
5
1.41 127
35.7 1/2"-13UNC-2B Thru Mounting Pattern
1 1/2" SAE code 61
flange
9.92
252
Static indicator
port 3.5
G 1/2" 88.9
4.78
2 121.5
50.8
16.59
RFM 661: 421.5
[19.98]
INLET PORT RFM 851: 507.5
2 1/2" SAE Flange 2.17
Code 61 55 11.81
RFM 661: 300
[15.20]
RFM 851: 386
1/2"-13UNC-2A Thru
6.5
165.2 G 2 1/2"
[Top of Bowl] OUTLET
8.66
220
bolt circle 0.53
13.5
4 places
6.69
170
Tank Opening
Mounting Pattern
3.5
88.9 Threaded INLET
8.75
[9.00]
222.2
228.6 9.25
235
1/2"-13UNC
INLET Port
2 1/2" SAE code 61 flange
Standard
(optional)
INLET
[17.76]
RFM 975: 451
[35.5]
5.98 RFM 1100: 902
152
8.39
213
Bolt circle
Mounting Pattern
RFM 75/165/185
RFM 50/-4L Housing & RFM 75/165/185/-4L Housing
Q in l/min Q in l/min
0 10 20 30 40 50 60 0 40 80 120 160
10 5 0.30
0.6 0.25
8 4
0.5
0.20
6 0.4 3
0.15
4 0.3 2
0.2 0.10
2 1 0.05
0.1
0 0 0 0
0 2 4 6 8 10 12 14 16 18 0 10 20 30 40 50
Q in gpm Q in gpm
RFM 90/150
& RFM 90/150/-4L Housing RFM 210 / 270 Housing
Q in l/min Q in l/min
0 40 80 120 0 100 200 300
7 6 0.4
6 5
0.4
5 0.3
4
4 0.3
3 0.2
3 0.2
2
2 0.1
1 0.1 1
0 0 0 0
0 10 20 30 40 0 20 40 60 80 100
Q in gpm Q in gpm
Betamicron ...R...BN4HC
Size 3 μm 5 μm 10 μm 20 μm
0975 R XXX BN4HC 0.050 0.040 0.030 0.020
1100 R XXX BN4HC 0.030 0.020 0.020 0.010
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0050 R XXX ON N.A. N.A N.A. 0.296 N.A. N.A.
0075 R XXX ON 1.405 1.065 0.735 0.401 0.263 0.241
0090 R XXX ON 1.235 0.719 0.521 0.333 0.236 0.176
0165 R XXX ON 0.774 0.518 0.404 0.221 0.123 0.133
0185 R XXX ON 0.571 0.408 0.315 0.161 0.091 0.077
0210 R XXX ON 0.311 0.18 0.14 0.084 0.055 0.048
0270 R XXX ON 0.201 0.116 0.091 0.054 0.036 0.031
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0500 R XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
0660 R XXX ON 0.196 0.093 0.066 0.037 0.031 0.025
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
B B
Technical Specifications
Features Mounting Method 4 mounting holes - filter housing
Port Connection
• D esigned to meet and comply with HF4 Automotive standard
and SAE J2066 standard. Inlet SAE-24, 1 1/2” NPT, 1 1/2” BSPP,
• Inlet port options include SAE straight thread O-ring boss, SAE 1 1/2” Flange, Code 61
Flange, BSPP and NPT ports to allow easy installation without Outlet
costly adapters. HF4R 09/18/27 1 1/2” NPT male
• O -ring seals are used to provide positive, reliable sealing. Choice Flow Direction Inlet Outlet
of Nitrile rubber (NBR), or Fluorocarbon elastomer (FKM) O-ring HF4R Side Bottom
material provides compatibility with petroleum oils, synthetic
fluids, water-glycols, oil/water emulsions, and water based fluids. Construction Materials
• In-tank design requires minimal space for installation. Head, Lid Aluminum
• Provision is made for an additional inlet port to allow two return Bowl Carbon Steel
lines to be connected to the same filter. Flow Capacity
• Filters include 1 1/2” threaded NPT outlet connection. HF4R09 50 gpm (189 lpm)
HF4R18 75 gpm (378 lpm)
HF4R27 100 gpm (454 lpm)
Housing Pressure Rating
Max. Allowable Working
Pressure* 100 psi (7 bar)
Fatigue Pressure Contact HYDAC
Burst Pressure Contact HYDAC
Applications Element Collapse Pressure Rating
BN, BN4AM, AM, W, P/HC 145 psid (10 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
Agricultural Automotive Construction Gearboxes oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
All Other Indicators Gauges (E / ES)
P = 14.5 psi (1 bar) -10% P = 11.6 psi (0.8 bar)
P = 29 psi (2 bar) -10% P = 20 psi (1.4 bar)
P = 36 psi (2.5 bar) -10% P = 29 psi (2 bar)
Industrial Steel / Heavy
Industry Bypass Valve Cracking Pressure
∆P = 25 psid (1.7 bar) +10% (optional)
∆P = 40 psid (2.7 bar) +10% (standard)
∆P = 50 psid (3.4 bar) +10% (contact factory)
*Note: All HF4R Filters MAWP reduce to 101.5 psi (7 bar) when using the
following “VR” indicators: B, BM, E, ES, GC, LE, LZ.
Any filters incorporating a VMFXE.X/3 or VMFXES.X/3 static gauge
indicator (1/8” NPT thread) will be de-rated to an MAWP of 60 psi (4 bar).
7 6.25
177.8 158.8
Bolt Circle
0.44
11.1
4 PL'S
Static clogging indicator/
Vent port G 1/2" plug Equally Spaced 5.06
129
Reservoir
opening
Mounting Pattern
[9.80]
HF4R-09: 249
[19.13]
HF4R-18: 486
[28.50]
HF4R-27: 724
Clearance required
for element removal
Optional
2nd INLET
[Matching
Ports] 6.38
1/8" NPT
162.1
static clogging indicator
Threaded ports port boss (standard)
HF4R-09: [4.16] Vent G 1/2"
[180.9]
105.9 or optional
7.12 static clogging
4.26
4 bolt flange indicator port
HF4R-18/27: 108.2
1.5" NPT
OUTLET
Size 09 18 27
Weight (lbs.) 13 17.5 23.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Autospec HF4 Paper 5.03.XXDXXP Low Collapse Autospec HF4 Water 5.03.09DXXAM & BN/AM
Size 3 µm 10 µm 25 µm Size 3 µm 10 µm 40 µm
5.03.09DXXP 0.250 0.120 0.080 5.03.09DXXAM N/A N/A 0.125
5.03.18DXXP 0.090 0.050 0.030 5.03.09DXXBN/AM 0.320 0.230 N/A
5.03.27DXXP 0.020 0.010 0.010 Notes: Requires stacking for 18” and 27” configurations.
Water retention (per 9” section) 500ml at 2 gpm; 150 ml at 20 gpm
VA VA
VA VA
B1 B1
V2 V2
B2 B B2 B
V3 V1
V1
T T
/-ND (with pressure release orifice) /-NRD /-NRF125 (with anti-cavitation valve
and a coarse filter with 125 µm)
A A A
VA VA VA
VA VA
B1 B1 B1
V2 V2 B2 B V2
B2 B B2
B
V1 V1 V3 V1
T T T
Technical Specifications
Mounting Method 100 2 mounting holes
201 - 800 4 mounting holes
Features Port Connection Return / Suction
• R KM is a combination open loop return and closed loop suction 100 SAE-8 / SAE-8
boost filter in one housing. SAE-12 / SAE-12
• The return line flow of the operating hydraulics is fed to the SAE-16 / SAE-16
filter via port A (inlet) and is cleaned by the filter element (full flow 201/251 SAE-20 / 2 x SAE-16
return line filtration). A pressure (standard = 7 psi) is applied by the 300 SAE 1 1/2” CS, Code 61-Split Flange (SF)
back-pressure valve V1. This insures that the filtered, precharged / 2 x SAE 1 1/4” CS, Code 61-Split Flange (SF)
return line flow is available to the hydrostatic feed pump via ports 350 SAE-24 / SAE-16
B (full flow suction boost filtration). Excess fluid is drained via the 400/800 R1–2” SAE flange / Cust. specified or
back-pressure valve to the tank (port T). R1–2 1/2” SAE flange / Cust. specified
• A bypass valve V2 (standard = 36 psi) is incorporated in the filter Flow Direction Inlet: Side Outlet: Side & bottom
housing to relieve excessive back-pressures in the element
(important on cold starts). Flow from the tank can be drawn via
Construction Materials
the anti-cavitation valve V3 to the suction side for a short time Head Aluminum
(emergency function). Housing/Bowl Steel (100/201/251/350/400/800)
• Full flow finest filtration (10 µm, 15 µm absolute) of the return line Polyamide (300)
and hydrostatic feed pump extends the service life of your Lid Polyamide (100/201/251/350)
components. Aluminum (300/400/800)
• Outstanding cold start characteristics due to the precharge via Flow Capacity
the back pressure valve (standard = 7 psi). 100 26 gpm (100 lpm)
• Due to the advanced RKM element technology and specially 201 52 gpm (200 lpm)
developed bypass valves, the lowest back-pressures can be 251 66 gpm (250 lpm)
achieved across the filter even at very low temperatures. 300 79 gpm (300 lpm)
• One tank cutout for up to 6 suction and 3 return lines. 350 92 gpm (350 lpm)
• Aluminum alloy is water tolerant - anodization is not required for 400 105 gpm (400 lpm)
water based fluids (HWBF). 800 211 gpm (800 lpm)
• RKM elements do not incorporate bypass in the end cap —the Housing Pressure Rating
bypass is located in the RKM housing. Max. Allowable Working Pressure* 145 psi (10 bar)
Fatigue Pressure Contact HYDAC
Burst Pressure Contact HYDAC
Applications Element Collapse Pressure Rating
MM 145 psid (10 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
Agricultural Construction oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
P = 29 psi (2 bar) -10% (standard)
P = 72 psi (5 bar) -10% (optional)
Bypass Valve Cracking Pressure
∆P = 36 psid (2.5 bar) +10% (standard)
∆P = 87 psid (6 bar) +10% (optional)
Back Pressure Valve Cracking Pressure
∆P = 7 psid (0.5 bar) +10% (standard)
∆P = 43 psid (3 bar) +10% (optional)
*Note: All RKM Filters MAWP reduce to 7 bar (101.5 psi) when using the following
“VR” and “VMF” indicators: B, BM, E, ES, GC, LE, LZ
S2 S1
R1
S2 R1 S1
R1
Size 201/251
2.0 1.0 Type Mounting Position of Type of Clogging
Measuring
Code the Clogging Indicator Indicator
2.0
on the filter inlet –
1.0 return line before the filter element
opposite side
on the filter inlet –
3.0 2.0 return line before the filter element
left-hand side
3.0 on the filter outlet –
3.0 vacuum after the filter element
1.0, right-hand side
3.0
1.0,
40°
3.0
°
Size 201/251/-MP1
40° 40
2.0,
Size 300
1.0, Type Mounting Position of Type of Clogging
Measuring
3.0 4.0 Code the Clogging Indicator Indicator
3.0 4.0 on the filter inlet –
1.0 return line before the filter element
left-hand side
on the filter inlet –
2.0, 1.0, 2.0 return line before the filter element
right-hand side
3.0 4.0
on the filter outlet –
3.0 4.0 3.0 vacuum after the filter element
1.0 2.0 left-hand side
on the filter outlet –
4.0 vacuum after the filter element
right-hand side
1.0
1.0 2.0
2.0 Size 350 Type Mounting Position of Type of Clogging
Measuring
Code the Clogging Indicator Indicator
on the filter inlet –
1.0 1.0 differential pressure before and after element
2.0 1.0 right-hand side
2.0 on the filter inlet –
3.0 2.0 return line before and after element
left-hand side
1.0,
3.0
3.0
40°
+ = T T
Anti-cavitation
T
Anti-cavitation Throttle in back
valve* with coarse valve* in the pressure valve “V1”
strainer element bypass for reducing pressure
for filtered
A oil also in valve “V2” and draining oil
anti-cavitation mode A filtered oil
for finely
also in anti-cavitation *not for RKM 355
V2 VA mode VA = clogging indicator
B1 V2 VA
V3 B
contaminatedB2 filtered,
oil from pre-charged
V3 V1the V1
operating oil for the boost
hydraulics
T (QR) pump (QS)
A T
V2 VA
B1
Working B2 A
hydraulics V1
V3 suction line,
return line,
filter inlet (A) V2 VA filter outlet (B)
T B1
B2
filter element FE
V3 V1
A T pre-charged
oil for the boost
pump (QS)
V2 VA
return B1
to the tank
B2
V1
V3
back-pressure
valve V1
T
bypass valve V2
outlet to the
tank (T)
A
Application example for the RKM in mobile machines. Function of the RKM. VA
V2
B1
D44 PN#02081318 / 07.19 / FIL1907-2109
B2
V1
LOW PRESSURE FILTERS
Dimensions
RKM 100
5.39
137
4.53
115
2.17
55 1.06
SW 27
0.43
11 4.92
125
1.89
48
1.33 2.76
33.8 70
4.33 [12.99]
330
110 Clearance required
for element removal
Suction
OUTLET 4.09
1 5/16"-12UN-2B 1.02 103.8
SAE-16 Port Indicator
26 port 1.97
2.05 4.02
suction line 50
1.63 52 102
41 HEX
Return 1.1
INLET 0.47 Adapter
for 28
1 5/16"-12UN-2B 12 10.59 14.61
SAE-16 Port 1" BSPP-SAE-16
9.8 269 371 PN 2700909 Indicator
2.87 249 port
73 return line
1.42 2.87
36 73
OUTLET
(Tank)
3.15
0.43
80
11
Tank opening
Use M8 bolt
4.53
115
Bolt circle
Mounting Pattern
Size 100
Weight (lbs.) 3.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
0.43
11
2.87
73
[12.99]
330
Clearance required
2.91 for element removal
S1 74 4.33
Suction
OUTLET 110
2.17
S2 55
2.17 Suction
55 OUTLET
0.49
4.02
12
102 2.19
55.5
1.02 R3
26 0.77 INLET
R1 19.5
INLET 10.57 1.02
269 26
R2
9.76 INLET
248 14.59
371
Outlet
(Tank) 1.42 2.87
36 73
0.43
11
Use M8 bolt 3.15
80
Tank opening
4.53
115 Mounting Pattern
Bolt circle
Size 100
Weight (lbs.) 4.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
6.5
3.54 165
90 Bolt circle
6.3
160
RKM201: [18.50]
470
RKM251: [21.10]
Indicator 536
Port 2.2 Clearance required
Return Line 56 for element removal
Indicator
Port 5
Suction line 127
1.81
46 1.81
46
0.47 19.92
12 RKM201: 506
[22.52]
RKM251: 572
Return
INLET 1.26 1.0
Indicator 14.92
1 5/16"-12 UN 32
RKM201: 379
(SAE-16) Port
2.44 G 1/8" [17.52]
62 RKM251: 445
Suction
OUTLET
3.94 1 5/16"-12 UN
100 13.94
(SAE-16)
RKM 201: 354
[16.54]
RKM 251: 420
1.73 OUTLET
44 (Tank)
4.33
110
0.43
Tank opening
11
Use M8 bolts
6.5
165
Bolt circle
Mounting Pattern
5.51 Indicator
2.06 140 port
52 suction line
0.43 3.35
11 85
1.42
6.5 SW 36
165
Bolt circle
Indicator
port
return line 3.54 3.35
90 85
3.05 5.2
77.5 132
1.26
3.03 RKM 201
32
77 0.47 19.92
12 506
2.0 Indicator Suction RKM 251
Port OUTLET
G 1/8" 1 5/16"-12 UN RKM 201 RKM 201 [22.52]
(SAE-16) 13.94 14.92 572
2 places 354 379
3.94 RKM 251 RKM 251
Return [16.54] [17.52]
INLET 100
1 5/16"-12 UN 420 445
(SAE-16)
1.73
44
OUTLET
(Tank)
0.43
4.33 Port Configuration RKM 201 / 251 Multiport
110 Position in code 1 2 3 4 5
11
Tank opening
Use M8 bolts Connection R1 R2 R3 S1 S2
SAE-12 C C C C
SAE-16 D D D D D
SAE-20 E
Port plugged 0 0 0 0 0
6.5
Special port Z Z Z Z Z
165
Mounting Pattern
Bolt circle
9.73
247.1
7.13
181
[19.68] 8.69
500 220.6
Clearance required Return
for element removal INLET
4.13 3.94 1 1/2"-12 SAE code 61
105 100 Flange Head
2.68 1.85
68 47
Indicator
Port 5.48
3.0 139
2.36 2.52 2.05
60 64 52
Indicator
Suction Port
Indicator OUTLETS Indicator
1.0 Port
Port 1 1/4" SAE code 61
4.0 Flange Head 19.14 2.0
5.28
486
134
4.96 Tank opening
126
Top of Bowl
13.66
347
2.2
56
OUTLET
(Tank)
5.28
134
0.43
Tank opening
11
Use M8 bolts
7.09
180
Bolt circle Mounting Pattern
Size 300
Weight (lbs.) 10.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Optional
7.19
182.5 6.89
175
3.94 Bolt circle
100
1.37
Hex 34.8
[25.00] ∆P Clogging
635 indicator
Clearance port
required for 1.1 Suction G 1/2" 1.0
element removal 28 OUTLET
1 5/16"-12UN
SAE-16 port
3.35
85
5.63
143 Optional 3.39
86
1.65
1.73
42
44
Return
INLET 3.76
1 7/8-12UN 95.5
Thermo sensor port
SAE-24 port M14x1.5 to ISO 6149
29.53
750
0.98 3.52
23.9 25 89.5
607
4.29
109
Bottom
of Bowl
OUTLET
0.45 (tank)
11.5
Use M8 bolts 4.61
117
Tank opening
6.89
175
Bolt circle
Mounting Pattern
Size 350
Weight (lbs.) 13.9
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
8.74
222
9.37
238
6.5 OUTLET
(tank)
165
Top of Bowl
S8 S6 S7
S9 Suction Suction Suction
Suction OUTLETS OUTLETS OUTLETS
OUTLETS (Optional) (Optional)
2.15
54.5
4.82
122.5
0.53
13.5
R3 Use M10 bolts 6.69
Inlet 170
Optional Tank opening
View Y
View X 8.66
220
Bolt Circle Mounting Pattern
0 0 0 0 0 0
0 4 8 12 16 20 24 28 32 0 15 30 45 60 75 0 10 20 30 40 50 60 70 80
Flow in gpm Flow in gpm Flow in gpm
0 0 0 0.0 0 0
0 20 40 60 80 100 0 40 80 120 160 0 20 40 60 80 100 120 140
Flow in gpm Flow in gpm Flow in gpm
RKM 800
Flow in l/min
0 150 300 450 600 750 900
15 1.0
12 0.8
9 0.6
6 0.4
3 0.2
0 0
0 40 80 120 160 200 240
Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Mobilemicron RK …RK…MM
Size 8 μm 10 μm 15 μm
0100 RK XXX MM 0.095 0.095 0.061
0201 RK XXX MM 0.041 0.041 0.026
0251 RK XXX MM 0.032 0.032 0.020
0300 RK XXX MM 0.034 0.034 0.021
0350 RK XXX MM 0.016 0.016 0.011
0400 RK XXX MM 0.031 0.031 0.019
0800 RK XXX MM 0.024 0.024 0.015
(Standard)
(Suction)
B B
Technical Specifications
Mounting Method
MF40/80/85 2 mounting holes
MF90/95 3 mounting holes
MF160/180 2 or 4 mounting holes
Features MF190/195 2 or 3 mounting holes
• M F Filters are manufactured with an aluminum head. MFD 2 mounting holes
MFDS 4 mounting holes
• Choice of NPT, SAE straight thread O-ring boss, and SAE 4-bolt
flange porting to allow easy installation without costly adapters. Port Connection
• Quick easy element changeouts. MF40 SAE-6
• MF Filters are designed to be used with hydrocarbon based MF80/85 3/4” NPT, SAE-12, 1” NPT, SAE-16
fluids only – (not suitable for use with high water based fluids or MF90/95 3/4” NPT, SAE-12, 1” NPT, SAE-16
phosphate esters) MF160/180/190/195 1 1/4” NPT, SAE-20, 1 1/2” NPT, SAE-24
• MF Filters are available in static and differential pressure MFD160/180 1 1/2” NPT, SAE-24
sensing configurations. MFDS160/180* 2” SAE Flange Code 61, 1 1/2” NPT Comb. Port
• Static Indication for Mobile/Return Applications - Sizes MFDS190/195* 2” SAE Flange Code 61, 1 1/2” NPT Comb. Port
40/80/85/160/180 *Note: Max. allowable torque for flanged ports is 26 ft-lbs (1/2” - 13 UNC bolts)
• Differential Indication for Inline Applications - Sizes Flow Direction Inlet: Side Outlet: Side
90/95/190/195 Construc. Materials Head: Aluminum Can: Steel
Flow Capacity
40 7 gpm (26 lpm)
80 15 gpm (57 lpm)
85 25 gpm (95 lpm)
90 15 gpm (57 lpm)
95 25 gpm (95 lpm)
160,190 30 gpm (114 lpm) per can
180,195 60 gpm (227 lpm) per can
Housing Pressure MF40/80/85/160/
MF90/95
Rating 180/190/195
Max. Allowable
Applications Working Pressure** 120 psi (8 bar) 250 psi (17 bar)
Fatigue Pressure Contact HYDAC
Burst Pressure Contact HYDAC
Element Collapse Pressure Rating
BN, P, AM 80 psid (5.5 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)
Agricultural Automotive Construction Gearboxes Consult HYDAC for applications operating below 14°F (-10°C)
Fluid Compatibility
Compatible with all petroleum oils and synthetic fluids rated for use
with Nitrile rubber (NBR) seals and aluminum and steel metals
Indicator Trip Pressure ∆P Units (Differential)
20 psid (1.4 bar) -10% ∆P 14.5 psid (1 bar) - 10%
25 psid (1.7 bar) -10% ∆P 22 psid (1.5 bar) - 10%
Industrial Pulp & Paper Steel / Heavy 40 psid (2.7 bar) (B3.4 Bypass) ∆P 44 psid (3 bar) - 10%
Industry Vacuum = 2 psid (0.1 bar) (Suction)
Bypass Valve Cracking Pressure
∆P = 3 psid (0.2 bar) +10% (for suction applications)
∆P = 25 psid (1.7 bar) +10% (standard for nominal/surface type filters)
∆P = 50 psid (3.4 bar) +10% (standard for absolute/depth filters)
(standard for absolute/depth type BN filters, MF
80/90/95/160/180/190/195, MFD 160/180, MFDS 160/180)
**Note: A
ll MF, MFD, MFDS MAWP reduce to 60 psi (4 bar) when using the
following ”VMF” indicators: B, BM, E, ES, GC, LE, LZ.
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
[0.38]
1/4"-20UNF X 9.5 DP
2 PL'S
1.50
38.1
1.13
INLET OUTLET 28.7
MF 40
[3.46] 4.61
87 117
MF 45
[5.5]
139
2.99
76 [0.40]
10
Clearance
required
for element
removal
Size 40 45
Weight (lbs.) 1 1.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
1.50
38.1
3.69
93.8 Optional Gauge
Port
1/8" NPT
Location 2
3.65
92.7 H1 H2
INLET OUTLET H3
MF 80
[5.38] L
138
MF 85
[8.08]
207
3.66 [0.63]
93 16
Clearance
required for
element removal
Size 80 85
Weight (lbs.) 1.8 2.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
2.00
50.8
∆P Indicator
(Electric or Visual)
2.12
53.9
5/16"-18UNC-2B X [0.50]
12.7
3 PL'S
4.14
1.00
105.2
25.4
MF 90
[5.88] L
150
MF 95
[8.03]
204
3.66
[1.50]
93 38
Clearance
required for
element removal
SAE-16
3/4” NPT
SAE-12 [8.03]
MF95
1” NPT 204
SAE-16
Size 90 95
Weight (lbs.) 2.7 3.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
1.88
47.8
2.50
63.5
1.25
31.8
Location 4 Location 3
5.34 1.88
135.7 47.8
1 1/2" NPTF
5.40 SAE-24
137 (3 Bolt Mounting)
H1 H2 (Special Order)
1.50
H3 38.1
INLET OUTLET
MF 160 1.88
[6.70] L 47.8
175
MF 180
[10.9]
277
1 1/4" NPTF
SAE-20
(4 Bolt Mounting)
[1.50]
4.99 38
126.7 Clearance
required
for element
removal
[0.56]
5/16"-18UNC-2B INCH X 14.3 DP
Indicator 2 PL'S
Position 2 0.56 ∆P Indicator
(Optional) M10 X 1.5 X 14.2 DP (Electric or Visual)
3 PL'S
1.87 1.88
47.5 47.8
Indicator
Position 1
(Standard) 1.50
38.1
3.00 3.00
76.2 76.2
1 1/4" NPT 1 1/4" BSPP - Discontinued
SAE-20 (3 Bolt Mounting)
(2 Bolt Mounting)
5.34
135.6 1.12
28
MF 190
[6.90] L
175
MF 195
[10.9]
277
4.99 [1.50]
126.7 38
Clearance
required for
element
removal
1/8" NPT
Pressure
gauge OUTLET
6.47
3.25 2.56 164.3
82.6 65
2.68 2.9
68.1 73.7
INLET
4.9
124.5
[16.73]
2.8 MFD 160 : 425.05
71.1 24.73
MFD 180 : 628.2
[1.5]
38.1
Clearance
required
for element
removal
7.56
191.9
4.72
Location 4 Optional gauge port
(1/8" NPTF) 119.8
Inlet Pressure Locations
(Locations 1,2,3, or 4)
Location 1
3/8-16UNC-2B x 15.8 DP. (1/8" NPTF)
[0.625]
Mtg. Holes Alternate Indicator
4 PL'S Position
MFDS 190/195
6.50
165.1
2.00
50.8
Alternate Indicator
Position
MFDS 190/195 Location 2
(1/8" NPTF)
Location 3
(1/8" NPTF) INLET & OUTLET port sizes
1 1/2" NPTF &
2" SAE, CODE 61 Flange Combination
2.44
61.9
3.41
86.6 INLET OUTLET
0.31
7.8
1.06 MFDS 160/190
14.37 [6.70]
1/2-13UNC-2B X 27 DP
365.1 175
4 PL'S
MFDS 180 /195
[10.9]
277
5.10
129.5
[1.5]
38.1
Clearance
required
for element
removal
MF 40 MF 80 / 85 MF 90 / 95
MF 160 / 180 / 190 / 195 MFD / MFDS 160 / 180 / 190 / 195
5.12
130
∆P clogging
indicator
port
G 1/2"
0.24 5.91
6 150
1 5/8"-12UN-2B 1.71
SAE-20 43.5
or
1 7/8"-12UN-2B
SAE-24
or
1 1/2" SAE DN 38 INLET OUTLET
Flange FLN 160:
INLET and OUTLET 2.99
10.83
76
275
FLN 250:
[14.37]
365
FLN 400:
[20.28]
515 4.17
106
[3.35]
85
Clearance required
for element removal
2.75
69.9
1.26
M12X19.5 dp
32 Hex
1.41
35.7 Drain plug (Included)
G 3/8"
12.0
10.5
9.0
7.5
6.0
4.5
3.0
1.5
0.0
0 13 26 40 52 66 79 92 106
Q in gpm
6m
∆p in bar
Element
0.8 12 K Factors 1.2 18
∆p in psid
∆p in bar
10m Viscosity1.0
Actual 15 Specific Gravity
(SUS) x Actual 10m
0.6 9
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 25m 141 SUS 0.8 12 0.86
25m
0.4 6 0.6 9
0.4 6
0.2 3
BN4HC 0.2 3
...DN…BN4HC (Betamicron Low Collapse)
0.0 0 0.0 0
Size
0 13 26 3 µm 40 52 6 µm 0 10 µm
26 52 7925 µm 106
0160 DN XXX BN4HC 0.434 0.280 0.187 0.143
Q in gpm Q in gpm
0250 DN XXX BN4HC 0.280 0.176 0.115 0.099
0
0400 DN XXX BN4HC50 100 0.176 150 200 0.110 0 100
0.071 200 300
0.055 400
Q in L/min Q in L/min
0400 DNXX
BH4HC BN/HC W/HC
...DN…BH/HC (Betamicron High Collapse)
2.0 30Size 3 µm 6 µm0.08 1.20 10 µm 25 µm size 160
1.80160 DN
27XXX BH4HC 0.439 0.2800.07 1.05 0.209 0.137
1.6 24
0250 DN XXX BH4HC 0.296 0.1870.06 0.90 0.154 0.104
1.4 21
∆p in psid
∆p in bar
1/4" NPT
14mm HEX
2.44 7.51
62 190.8
2.26
57.5
1.1 4.94
-DDE
28 125.5
Clogging Indicator port 1 5/8"-12UN-2B
G1/2 SAE-20
Dirty Side Vent
OR
G1/8 -DDF
SW5 1 7/8"-12UN-2B
2 Places SAE-24
OR
-DDK
11.1 1 1/2" SAE DN 38
282 Flange
1.69
INLET OUTLET 43
5.43
FLND 160: 138
11.69
297
FLND 250:
[15.24]
387
FLND 400:
[21.14]
537
1.26
[3.35] 32
85 Drain plug
5.12 (included) HEX
Clearance 130 4.17
G3/8 106
required for
element removal
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
FLND 160/250/400
[1.41]
35.7
1-7/8"-12UN-2B 1-5/8"-12UN-2B
SAE-24 Port SAE-20 Port
INLET & OUTLET INLET & OUTLET
Flange SAE (1 1/2" Flanged)
DN38
INLET & OUTLET
B B
Technical Specifications
Mounting Method See drawings
Port Connection
330 / 500 / 750 SAE DN 38 (1 1/2”) Code 61
1310 / 2610 4” SAE DN 102 Flange Code 61
(with M16 bolts included) - other
options available
1350 / 2650 SAE DN 51 (2”) Code 61
1.0 Version 2.0 Version 1350 / 2650 SAE DN (2 1/2”) Code 61
SAE DN 76 (3”) Code 61
Flow Direction
Features 1.0 version Inlet: Side Outlet: Bottom
2.0 version Inlet: Side Outlet: Bottom
• N F Filters have an extremely large filtration area and flow capacity 1350 / 2650 Inlet: Side Outlet: Side
of 450 gpm (4” pipe size limitation)
• NF Filters can be configured for in-tank or in-line applications Construction Materials
• Vent and drain ports are standard Head, Housing, Lid Aluminum
• Aluminum alloy is water tolerant - anodizing is not required Elbows, Manifolds Ductile Iron
for high water based fluids (HWBF) Flow Capacity 4” Headers
• Screw-on lid provides easy access to filter element 330 80 gpm (303 lpm)
for replacement 500 132 gpm (500 lpm)
• Reusable contamination basket prevents re-entry of retained 750 200 gpm (757 lpm)
contaminants into the reservoir during element replacement 1310, 1350 343 gpm (1300 lpm)
(1.0 Version only) 2610, 2650, 5210, 7810, 10410 450 gpm (1700 lpm)
• F ilters can be fitted with clogging indicators to monitor the
6” Headers
contamination level of the element
• Flange connection bolts included for all SAE-DIN flange ports 5210..D7/D8 900 gpm (3407 lpm)
Note: This filter is configured with an …..R…. type (return/low pressure) 7810.. D7/D8 1350 gpm (5110 lpm)
element, so if the filter requires a bypass, the bypass is located in the 10410.. D7/D8 1350 gpm (5110 lpm)
closed end cap of the cartridge element. Housing Pressure Rating
Max. Allowable Working Pressure* 360 psi (25 bar)
Applications Fatigue Pressure 360 psi (25 bar)
Burst Pressure 1754 psi (121 bar)
Element Collapse Pressure Rating
ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, P/HC, AM 145 psid (10 bar)
V 435 psid (30 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Agricultural Gearboxes Industrial Power
Generation Consult HYDAC for applications below -22˚F (-30˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
Pulp & Paper Shipbuilding Steel / Heavy ∆P = 29 psid (2 bar) -10% 1.0 - Static
Industry ∆P = 72 psid (5 bar) -10% 2.0 - Differential
Bypass Valve Cracking Pressure
∆P = 14.5 psid (1 bar) +10%
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10%
*Note: All NF…1.0 Filters MAWP reduce to 7 bar (101.5 psi) when using the
following “VMF” and “VR” indicators: B, BM, E, ES, GC, LE, LZ.
Vent port
SW 6
G1/4" 1.47
37.3
Hex
∆P Clogging
indicator
port
G 1/2"
0.440
11.2
Thru
5.70 6.68
4 Places
144.8 169.7
5.63
143
7.00
177.8
Bottom View
Mounting Pattern
11.42
290
0.71
18
Thru NF 1310: [18.50]
470
NF 2610: [36.02]
915
Clearance required for
element removal
4.92
10.24
125 INLET
Vent Port SAE DN 100 260
G 1/2" 4" Flange Lid Top
Filling
Connection 3.06
Port 77.8
G 3/4" 4.33
110
Static Clogging
Indicator Port NF 1310: [23.86]
G 1/2" 606
NF 2610: [41.14]
7.87 1045
200
M16 X 2 X 24 Dp
4 Places
∆P Clogging
indicator port
(not used in 1.0
configuration
M16 X 2 X 23 Dp
G 1/2")
4 Places
5.12
130
9.21
234
OUTLET 11.02 Tank Cutout
SAE DN 280
11.42
4" Flange 3.06 0.71 290
77.8 18 Bolt circle
Bottom View
Mounting Pattern
11.42
290
NF 1310: [18.50]
470
0.71 NF 2610: [36.02]
915 10.24
18
Clearance required 260
Thru for element Lid Top
removal
Vent Port
G 1/2"
NF 1310: [23.23]
7.87 590
200 NF 2610: [40.51]
1029
Static clogging
indicator port
G 1/2"
(not used in the
M16X 2 X 24 Dp 2.0 configuration)
4 Places INLET
3.06 SAE DN 100
77.8 4" Flange Filling connection port
G 3/4"
INLET
SAE DN 100
4" Flange
7.68 Dirty Side Drain Port
195 G 1/2"
5.12 ∆P Clogging
130 4.92 OUTLET
indicator 125 SAE DN
port 100
G 1/2" 4" Flange
3.06 0.71
5.12
77.8 18 Thru
130
4 PL'S
11.02 M16 X 2 X 23 DP
280 4 Places
11.42
290
OUTLET
SAE DN 100
4" Flange Bottom View
Vent port
G 1/2"
9.84
250
NF1350 :[18.50]
470
NF2650 :[36.02]
915
Clearance required 10.24
for element removal
260
Lid top
26.89
NF 1350: 683
[44.17]
NF 2650: 1122
7.87
200
INLET OUTLET
M
4 Places
7.6
193
B 2.8
∆P Clogging 0.98 C 71
indicator 25 A
port Dirty side drain port ∆P Clogging
G 1/2" G 3/4" indicator
port
Dirty side drain port G 1/2"
G 3/4"
6.69
170
6.54
166
Port Connections
Flange A B øC M
2” SAE-DN 50 77.8 42.9 50 M12 x 1.75 x 19 DP
2 1/2” SAE-DN 65 88.9 50.8 65 M12 x 1.75 x 19 DP
3” SAE-DN 80 106.4 62.9 75 M16 x 2.0 x 24 DP 0.53
Bottom View 13.5 Thru
4” SAE-DN 100 130.2 77.8 100 M16 x 2.0 thru 4 Places
Mounting Pattern
25.66
11.42 651.8 9.82
290 250
0.71 19.27
18 489.5
Thru
[36.02]
915
Clearance 3.94
required Vent port 100
for element G 1/2"
removal Vent port 2 Places
G 1/2"
10.24
Inlet
SAE DN 100 260
4" Flange Lid top
Smooth
50 Face
1270
Static 7.87
clogging 0.75 200
indicator + 0.12
19 12.54 - 0.00
port Thru
G 1/2" INLET +3
8 Places SAE DN 100 318.5 0
2 Places
4" Flange
Filling Smooth
connection SAE DN 100
Face Blanking
port 5.12
G 3/4" 4" Flange
130 OUTLET
2 places ∆ P Clogging SAE DN 100
indicator 4" Flange Dirty side port
port Smooth G 1/2"
G 1/2" Face
OUTLET 2 places ∆P Clogging 3.94
SAE DN 100 indicator 100
4" Flange 3.06 port
Smooth 77.8 G 1/2"
Face 2 places
11.81 5.91
300 150
11.81 4.72
300 120
0.55
14
Thru
4 Places
Mounting Pattern
Size 5210
Weight (lbs.) 198.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
For complete dimensions please contact HYDAC to request a certified print.
Vent port
G 1/2"
3 Places
11.42
0.71 290
18
Thru
19.27
489.5
9.84
250
3.94
[36.02] 100
915 5.91 11.81
Clearance 150 300
required 35.04
for element 890
removal
Vent port
G 1/2" 10.24
260
Lid top
INLET
SAE DN 100
50.00 4" Flange 7.87
1270 Smooth 200
Face
INLET
Static 0.75 SAE DN 100
clogging 4" Flange
19 Smooth
indicator
port Thru Face
G 1/2" 8 Places
3 Places +0.00
12.58 - 0.00
Filling 0.12
connection 319.5+0
port 5.12 Dirty side
G 3/4" OUTLET drain port
3 places 130
SAE DN 100 G 1/2"
∆P Clogging 4" Flange
indicator 3 Places
Smooth
port Face
G 1/2"
3 places
OUTLET 3.94
SAE DN 100 100 17.72
4" Flange 450 ∆P Clogging
3.06 indicator
Smooth 35.06
Face 77.8 port
890.5 29.53 G 1/2"
750 3 places
11.81 13.72
300 348.5
0.55 4.72
14 120
6 Places Mounting Pattern
Size 7810
Weight (lbs.) 275.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
For complete dimensions please contact HYDAC to request a certified print.
49.28
1251.8
Vent port
11.42 G 1/2"
4 Places 9.84
290
250
19.27
0.71 489.5
18
3.94
11.81 100
[36.02] 300
5.91
915 Typ.
Clearance 150
required 10.24
for element Vent port
removal G 1/2" 260
INLET
SAE DN 100
4" Flange
50 Smooth
Static Face
1270 clogging 7.87
indicator 0.75 200
port 19 + 0.12
G 1/2" 12.54 - 0.00
4 Places Thru
8 Places INLET +3
SAE DN 4" 318.5 0
Filling Flange
connection smooth face
port 5.12 4" SAE DN
G 3/4" 130 OUTLET Blanking
4 places ∆ P Clogging SAE DN 4" flanges
indicator Flange
port smooth
G 1/2" face
OUTLET 4 places 3.94
5.91 100
SAE DN 100
4" Flange 150
3.06 ∆P Clogging Dirty side
Smooth 77.8 indicator drain port
Face port G 1/2"
G 1/2" 4 Places
4 places
11.81
300
11.81
300
11.81
300
0.55
14 4.73
Thru Mounting Pattern 120
8 Places
Size 10410
Weight (lbs.) 397
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include elements.
For complete dimensions please contact HYDAC to request a certified print.
11.81 5.91
300 150
29.99 [36.02]
761.8 915
Clearance
10.24 required
260 Manual vent for element
Lid top valves Option removal
G 1/2" ports
2 places
Drain
manifold
Filling connection 61.41 (Option)
G 3/4" 1559.7 15.55
3 places 395
6.25
OUTLET 158.7
6" ANSI CS
12.8 300 lb flange
325 25.84
26.67 656.3
677.4 ∆ P Clogging indicator
port G 1/2"
2 places
M16 X 2
1.5 Threaded
38.1 Typ
11.81 1.5 4
300 38.1 101.6
13.31
338.1
Mounting Pattern
11.81 11.81
300 300
5.91
150
39.88
1012.9
[36.02]
10.24 Manual vent 915
260 valves Option Clearance required
Lid top G 1/2" ports for element removal
3 places
Drain
manifold
Filling connection 61.42 (Option) 2.1 15.55
G 3/4" 1560 53.2 395
3 places
6.25
12.8 158.8 OUTLET
325 6" ANSI CS
300 lb flange
26.67
677.4
∆ P Clogging indicator
port G 1/2"
3 places
M16 X 2
1.5 Threaded
38.1 Typ
4
11.81 11.81 101.6
300 300 1.5
38.1
25.12
638.1
Mounting Pattern
NF 330/500/750 HOUSING
Q in l/min
0 100 200 300 400 500
0.8
10
0.6
8
6 0.4
4
0.2
2
0 0
0 20 40 60 80 100 120 140
Q in gpm
2.0 0.1
0.1 1.0
1.0 0.05
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0500 R XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
0750 R XXX ON 0.116 0.061 0.05 0.029 0.019 0.018
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0500 R XXX ECON2 0.165 0.104 0.071 0.044
0750 R XXX ECON2 0.071 0.049 0.033 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
(1.0)
B
B B
Version 1.0 Version 2.0
33 39 30 33 39
60 69
Version 2.0 pictured
93 99 93 99
Features 0 0 = Pointed to Top 33 = Stand Configuration
• N FD Filters have an extremely large filtration area and flow 3 = Pointed to Front (not given as supplementary
capacity of 450 gpm (4” pipe size limitation).
• NFD Filters can be configured for in-tank or inline applications
9 3 6 = Pointed to Bottom details)
9 = Pointed to Back
• Vent and drain ports are standard First Number = Inlet Orientation
• Aluminum alloy is water tolerant - anodization is not required for 6 Second Number = Outlet Orientation
high water based fluids (HWBF)
• Screw-on lid provides easy access to filter element for Technical Specifications
replacement
Mounting Method See drawings
• Reusable contamination basket prevents re-entry of retained
contaminants into the reservoir during element replacement Port Connection SAE DN 102 Flange Code 61
(1.0 Version only) Flow Direction
• F ilters can be fitted with clogging indicators to monitor the 1.0 version Inlet: Side Outlet: Bottom
contamination level of the element 2.0 version Inlet: Side Outlet: Side
• NFD duplex filters have a ball-type diverter valve to provide Construction Materials
continuous filtration and eliminate the need to shut-down the
system during element changeout Head, Housing, Lid Aluminum
Elbows, Manifolds Ductile Iron
• Flange connection bolts included for all SAE-DIN flange ports
Note: This filter is configured with an …..R…. type (return/low pressure) Flow Capacity
element, so if the filter requires a bypass, the bypass is located in the 1310 343 gpm (1300 lpm)
closed end cap of the cartridge element. 2610, 5210, 7810, 10410 450 gpm (1700 lpm)
Housing Pressure Rating
Max. Allowable Working Pressure* 360 psi (25 bar)
Applications Fatigue Pressure 360 psi (25 bar)
Burst Pressure Contact HYDAC office
Element Collapse Pressure Rating
ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, P/HC, AM 145 psid (10 bar)
V 435 psid (30 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Agricultural Automotive Construction Gearboxes
Consult HYDAC for applications below -22˚F (-30˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
Industrial Offshore Power Pulp & Paper ∆P = 29 psid (2 bar) -10% 1.X - Static
Generation ∆P = 72 psid (5 bar) -10% 2.X - Differential
Bypass Valve Cracking Pressure
∆P = 14.5 psid (1 bar) +10%
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10%
*Note: All NFD…1.0 Filters MAWP reduce to 7 bar (101.5 psi) when using the
following “VMF” and “VR” indicators: B, BM, E, ES, GC, LE, LZ.
31.1 11.42
790 290
Bolt circle
20.08
510 11.02
280
5.31
135
0.71
3.06 19.69
18
77.8 500
Thru
Vent plug
5.12 G 1/2" 0.71
130 2 places 14.45
18
R367
8 PL'S
INLET flange detail
NFD1310 [18.50]
470
NFD2610 [36.02]
915
Clearance required
Vent Port
for element removal
G 1/2" 2 places
INLET 4" 10.24
SAE DN100 13.86
260
Flange 352
Lid Top
Filling connection port
G 3/4"
2 places NFD1310
[23.86]
Static clogging
606
indicator port
G 1/2" NFD2610
2 places [41.14]
9.13 4.33 1045
232 NFD1310
110 [10.00]
Tank opening INLET
254
7.87 4" sae-dn 100
flange NFD2610
200 [27.28]
693
Drain on contamination
OUTLET side G 1/2"
Drain on contamination
4" sae-dn 100 2 places
side G 1/2"
flange
2 places
5.12
M16X23 dp 130
8 places
3.06
77.8
11.02
280
19.68
0.71 500
0.71
5.31 18
18 3.06 135 Thru
Thru 77.8
Vent plug 8 places
G 1/2"
2 places
14.45
R367 NFD1310 [18.50]
5.12 470
130 NFD2610 [36.02]
915
INLET & OUTLET Flange Detail Clearance required
10.24
for element removal
260
Vent port Lid Top
G 1/2"
2 places
7.87
200
INLET
4" SAE-DN 100
Flange
NFD1310
[33.01]
Static clogging 838.4
indicator port
G 1/2" NFD2610
2 places
[50.38]
Filling connection port 1279.7
G 3/4" 13.58
2 places 345
Drain on contamination
side G 1/2" (Right Tower)
2 places
OUTLET 4"
SAE DN100 ∆ P Clogging Indicator
Drain on Flange Ports G1/2" 2 places 3.94
Contamination Side 100
G1/2" (Left Tower)
20.08 OUTLET
4" sae-dn 100 Drain on contamination
510 flange side G 1/2"
0.55
4.72 14
Mounting Pattern
120 Thru
4 places
22.05
560
0.71
3.06 19.27
18
77.8 15.14 9.82 489.5
Thru
384.5 249.5
29.51
749.5
5.12
130
INLET & OUTLET Flange Detail
14.45 [36.02]
R367 915
Clearance
Vent port required
G 1/2" 10.24
260 for element
4 places removal
Lid Top
7.87
200
INLET 49.4
SAE-dn 100 1254.7
4" flange
Static clogging
indicator port Dirty side
G 1/2" drain port
4 places 12.6 G 1/2"
320 4 Places
Filling
connection
port
G 3/4" 16.54
4 places 420
7.94
9.82
201.8
249.5
11.81
5.31
300
135
11.02
OUTLET
∆ P Clogging Indicator SAE-dn 100 280
G 1/2" 4" flange
4 places
61.57
1564
[45.67]
1160
[22.05] [11.81]
560 300
9.82 19.27
15.14 249.5 489.5
384.5 29.52
750
7.87
200 INLET
4" sae-dn 100
Static clogging
flange
indicator port 49.4
G 1/2"
6 places 1254.8
12.6
Filling 320 Drain G 1/2"
connection port Port 6 places
G 3/4" Contamination
6 places 16.54 Side
420
PN 413671
9.82 Bracket
249.5
5.31
135 OUTLET 11.02
4" sae-dn 100 280
∆P Clogging indicator flange
ports G 1/2" 11.81 13.7
6 places
300 348
77.8
1976
73.07
1856 0.55
45.67 14
1160 THRU
12 Places
22.05
560
11.81 4.72
300 120
13.7
348
11.02 11.02
280 280
Mounting Pattern
92.91
2360
69.29
1760
45.67
1160
22.05 19.27
560 489.5
15.14
384.5
0.71
18 3.06 29.51
Thru 77.8 749.5
14.45
5.12 R367
130
INLET & OUTLET Flange Detail [36.02]
915
Vent plug Clearance required
G 1/2" for element removal
10.24
8 places
260
Lid Top
0.55
14
Thru
11.02 16 places
280
Mounting Pattern
NFD 1310-2610 …1.X HOUSING NFD 1310-2610 …2.X HOUSING NFD 5210 …2.X HOUSING
Q in l/min Q in l/min Q in l/min
0 400 800 1200 1600 2000 0 400 800 1200 1600 2000 0 400 800 1200 1600 2000
10 16 14
0.6 1.0 12 0.8
8 12 0.8 10
0.6
6 0.4 0.6 8
8
6 0.4
4 0.4
0.2 4 4
2 0.2 0.2
2
0 0 0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Features
• T op access for easy element changeout. Technical Specifications
• All models have an air bleed valve (vent) installed in the lid.
Mounting Method
• Single large element with no leak points for highest efficiency and
dirt capacity NFH 2 mounting holes - filter head
• Lid with swing bolts for fast servicing without tools NFH Manifold Floor mounting brackets
• Drain port (right side of Inlet Port) SAE 12 (3/4”) SAE DN 102 Flange Code 61 (single tower)
Port Connection
• Clogging Indicator for local and/or remote signals SAE DN 102 (multi-tower)
• Easily banked in parallel (manifolded) for high viscosity Flow Direction Inlet: Side Outlet: Bottom
applications. Construction Materials
Notes: This filter is configured with an …..R…. type (return/low pressure)
Head, Lid, Elbows,
element, so if the filter requires a bypass, the bypass is located in the Ductile Iron
closed end cap of the cartridge element. Manifolds
Steel
Housing
Flow Capacity
1300 343 gpm (1300 lpm)
2600, 5200, 7800, 10400 450 gpm (1700 lpm)
(Flow limited by 4” pipe size)
Housing Pressure Rating
Max. Allowable Working
Applications Pressure 500 psi (34.5 bar)
Fatigue Pressure 500 psi (34.5 bar)
Burst Pressure > 1440 psi (100 bar)
Element Collapse Pressure Rating
ON, W/HC
290 psid (20 bar)
ECON2, BN4AM, AM,
145 psid (10 bar)
Automotive Gearboxes Industrial Power P/HC
Generation Fluid Temperature
14°F to 212°F (-10°C to 100°C)
Range
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
Pulp & Paper Shipbuilding Steel / Heavy appropriate seals are selected.
Industry
Indicator Trip Pressure
∆P = 29 psid (2 bar) -10% (standard)
∆P = 72 psid (5 bar) -10% (optional)
Bypass Valve Cracking Pressure
∆P = 43 psid (3 bar) +10%
∆P = 87 psid (6 bar) +10%
10.11
256.9
4.92
125
[1.19]
5/8-11UNC X 30.2 dp 5.13
4 places 130.2
OUTLET
4" Code 61
SAE-64 Flange
3.06
77.8
Bottom View
9.82
249.5
18.95
481.3
25.66
651.8
[36.30]
10.38 922
Vent valve (Brass) Clearance required
263.7 SAE-4 port for element removal
2 Places
7.00
177.8
53.10
INLET 1348.7
SAE-DN 100
4" Flange Top Of Valve
∆ P Clogging
indicator
port G 1/2"
2 places
8.69
220.6 12.62
320.6
3.06 0.75
77.8 19 3.43
thru OUTLET 87
4 Places SAE-DN 100
4" Flange Dirty Side Drain Port
5.12 SAE-12
130 1 1/16"-12UNF
2 Places
9.82
249.5
13.76
349.5 0.55
14
4 Places
11.81
300
Mounting Pattern
Size 5200
Weight (lbs.) 356
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
9.82
249.5
18.95
481.3
33.46
850
[36.30]
10.38 Vent valve (Brass) 922
SAE-4 port Clearance required
263.7
2 Places for element removal
7.00
177.8
53.10
INLET 1348.7
SAE-DN 100
4" flange Top Of Valve
∆ P Clogging
indicator
port G 1/2"
2 places
8.69
220.6 12.62
320.6
0.75
3.06 19 3.43
77.8 thru PN 413671 87
OUTLET
4 Places SAE-DN 100 Bracket
4" flange Dirty side drain port
SAE-12
5.12 1 1/16"-12UNF
130
9.82
249.5
13.76
349.5 0.55 4.72
14 120
6 Places
11.81 13.70
300 348
Mounting Pattern
Size 7800
Weight (lbs.) 477.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
11.81 11.81
300 300
9.82
249.5
18.95
481.3
49.28
1251.8
[36.30]
10.38 922
263.7 Clearance required
Vent valve (Brass) for element removal
SAE-4 port
2 Places
7.00
177.8
53.10
INLET 1348.7
∆ P Clogging SAE-DN 100 Top Of
indicator 4" flange Valve
port G 1/2"
2 places
8.69
220.6 12.62
320.6
0.75
3.06 19
77.8 OUTLET Dirty side Drain Port
thru SAE-DN 100 SAE-12
4 Places 4" flange 1 1/16"-12UNF
4 places
3.43
5.12 87
130
9.82
249.5
13.76 0.55
349.5 14 4.72
8 places 120
11.81 11.81
300 300
11.81
300
Mounting Pattern
Size 10400
Weight (lbs.) 684
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
∆P Housing
NFH 1300 / NFH 2600 NFH System 1
Multiplier 0.0689
Q in l/min 5200 73%
0 378 756 1134 1412
7800 61%
3 0.206
10400 48%
0 0
0 100 200 300 400
Q in gpm
2 0.138
Example
Conditions
1 0.0689 400 gpm flow
NFH 5200 manifold specified
∆P Curve = 2 psid
∆P 5200 = 2 psid X 0.73
0 0 = 1.5 psid Piping & Housing
0 100 200 300 400
Q in gpm ∆P Total System = 1.5 psid + ∆P Element
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element ∆P Calculations:
60 4
40 3
Sizing (K) Flow Factors below show the pressure drops across clean elements (excluding housings and piping). (K) Factors are calculated from
2
20mineral based fluid at viscosity of 141 SUS and specific gravity of 0.86. To determine clean ∆P for NFH manifolds with more than one housing,
1
use the appropriate sized single element (K) factor and multiply (total assembly flow rate divided by the number of housings in the manifold),
then correct for viscosity.
0
0
50 100 150 200 250 300 350 400
NFH 1300 and NFH 2600
(Single Filter)
Q in gpm
3
Example 1: Lube System Example 2: System Return Filter
Conditions Conditions
Viscosity = 500 SUS @ 120˚F Viscosity = ISO 68 Fluid 220 SUS @ 120˚F
Specific gravity = 0.86 Specific gravity = 0.86
Clean P, psid
2
Flow = 75 gpm Flow = 350 gpm
Low pressure drop essential 3µm Filtration (depth) ß (beta) = 1000
K Factor = 10 µm Optimicron® filter element K Factor = 3 µm Optimicron® filter element = 0.04
Selection - NFH 2600 Filter NFH 1300 and NFH 2600 Selection - NFH 7800 Filter
1
An NFH 2600 filter gives an Adjusted Clean(Single Filter)
Element ∆P as follows: Element ∆P = (350 ÷ 3 housings) x 0.04 x 220 x 0.86 = 7.28 psid
Clean ∆P = 75 gpm x 0.01 =30.75 psid 141 0.86
Clean ∆Padj. = 0.75 x 500 x 0.86 = 2.7 psid Housing ∆P = 1.05 (curve) x 0.61 x 0.86 x = 0.64 psid
141 0.86 0.86
1300 Polyester 0
Housing ∆P = “0” (negligible) Assembly ∆P = 7.28 psid + 0.64 psid = 7.92 psid 0 100 200 300 400
n P, psid
2
flow in gpm
D100 PN#02081318 / 07.19 / FIL1907-2109
LOW PRESSURE FILTERS
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Notes
03 09 00 03 09
33 39 30 33 39
60 69
Features
• Top access for easy element changeout.
• All models have an air bleed valve (vent) installed in the lid. 93 99 93 99
• Single large element with no leak points for highest efficiency
and dirt capacity 0 0 = Pointed to Top
• Lid with swing bolts for fast servicing without tools
3 = Pointed to Front
• Drain port - dirty side (right side of Inlet Port) SAE 12 (3/4”)
• Clogging Indicator for local and remote signals
9 3 6 = Pointed to Bottom
9 = Pointed to Back
• Easily banked in parallel (manifolded) for high viscosity
First Number = Inlet Orientation
applications. 6 Second Number = Outlet Orientation
• Available with Betterfit elements - consult HYDAC.
Notes: This filter is configured with an …..R…. type (return/low pressure)
element, so if the filter requires a bypass, the bypass is located in the Technical Specifications
closed end cap of the cartridge element.
Mounting Method loor mounting brackets
F
Port Connection SAE DN 102 Flange Code 61
Flow Direction (Standard) Inlet: Side Outlet: Side
Construction Materials
Head, Lid, Elbows, Manifolds Ductile Iron
Housing Steel
Flow Capacity
Applications 1300 343 gpm (1300 lpm)
2600, 5200, 7800, 10400 450 gpm (1700 lpm)
(Flow limited by 4” pipe size)
Housing Pressure Rating
Max. Allowable Working Pressure 500 psi (34 bar)
Fatigue Pressure 500 psi (34 bar)
Burst Pressure > 1440 psi (100 bar)
Automotive Gearboxes Industrial Power
Generation Element Collapse Pressure Rating
ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, AM, P/HC 145 psid (10 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Pulp & Paper Shipbuilding Steel / Heavy Compatible with all hydrocarbon based, synthetic, water glycol,
Industry oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure
∆P = 29 psid (2 bar) -10% (standard)
∆P = 72 psid (5 bar) -10% (optional)
Bypass Valve Cracking Pressure
∆P = 43 psid (3 bar) +10%
∆P = 87 psid (6 bar) +10%
30.46
773.6
20.08
510
5.31
5.12 135
130 19.29
3.06
77.8 490
0.12
5.12
3
130
36.81
NFHD 1300: 935
[54.09]
7.00
NFHD 2600: 1374
177.8 Dirty Side
Drain port
SAE-12
∆P clogging
1 1/16"-12un
indicator
2 places
port ← INLET
G 1/2" VIEW A
2 Places
9.69
12.75 246.1
323.9
← OUTLET
VIEW A
0.39 3.94
10 100
0.55 4.72
14 120
Thru
4 Places
20.08
510
Mounting Pattern
61.56
1564
Vent valve port
45.67 SAE-4 port
1160 7/16"-20UNF
4 Places
22.05
560
9.82
249.5
27.50
698.4
5.31
135
14.17 [36.77]
360 934
Clearance required
for element removal
0.12
INLET 3
7.00
53.07
177.8
1348
Top Of Valve
Dirty Side Drain Port
SAE-12
1 1/16"-12UNF
4 Places
8.69
220.6 ∆ P Clogging
indicator
port G 1/2"
4 places
OUTLET
3.94 5.31
100 135
45.67
1160
5.12
3.06 22.05 11.81
130
77.8 560 300
0.71 0.55
11.02 11.02
18 4.72 14
INLET & OUTLET 280 280
SAE-64, CODE 61 Flange 4 Places 120 Thru
Mounting Pattern
8 Places
Size 5200
Weight (lbs.) 803
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
79.18
2011
69.29
1760 Vent valve port
45.67 SAE-4 port
1160 7/16"-20UNF
6 Places
22.05
560
9.82
249.5
27.28
692.9
5.31
135
14.17 [36.77]
934
360
Clearance required
for element removal
0.12
INLET 3
7.00
177.8
53.07
1348
Dirty Side Drain Port
Top Of Valve SAE-12
1 1/16"-12UNF
6 Places
8.77
∆ P Clogging
222.8 indicator
port G 1/2"
6 places
3.85 5.31
OUTLET 97.8 135
73.07
1856
45.67
1160
5.12 11.81
3.06
130 300
77.8
22.04 13.70
560 348 4.72
120
0.71
INLET & OUTLET 18
SAE-64, CODE 61 Flange 4 Places
11.02 11.02
280 280
Mounting Pattern
Size 7800
Weight (lbs.) 1008
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
109.21
2773.8
92.91
2360
69.29
1760
45.67 Vent valve port
1160 SAE-4 port
7/16"-20UNF
22.05 8 Places
560
9.82
249.5
5.32
[36.77] 135
934
27.47 14.17 Clearance required
697.8 360 for element removal
0.12
INLET 3
7.00
177.8
53.10
1349 Dirty Side
Top Of Valve Drain Port
SAE-12
1 1/16"-12UNF
8 Places
8.69
220.6
∆P Clogging
indicator
port G 1/2"
8 places
OUTLET 3.94 5.31
100 135
92.91
2360
69.29
5.12 3.06 1760
130 77.8 45.67
1160
22.05
560
0.71
INLET & OUTLET 18
SAE-64, CODE 61 Flange 4 Places
11.02 11.02
280 280
Mounting Pattern
Size 10400
Weight (lbs.) 1459
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
∆P Housing
NFHD System Multiplier
5200 93%
7800 83%
10400 74%
Example
Conditions
400 gpm flow
NFHD 10400 manifold
specified = 9 psid
∆P Curve = 9 psid X 0.74
∆P 10400 = 6.7 psid Piping & Housing
Fluid Specific Gr = .86 psid
∆P Total System = 6.7 psid ∆P Housing + ∆P Element
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element ∆P Calculations:
Sizing (K) Flow Factors below show the pressure drops across clean elements (excluding housings and piping). (K) Factors are calculated from
mineral based fluid at viscosity of 141 SUS and specific gravity of 0.86. To determine clean ∆P for NFH manifolds with more than one housing,
use the (K) factors below and divide total flow rate by # towers per side.
Element ∆P = Elements (k) flow Factor x total flow x Actual Viscosity (SUS) x Actual Sp Gravity = 7.09 psid
filter towers (on one side) 141 0.86
Example
Conditions Selection - NFDH 10400 Filter
Lube system An NFHD 10400 filter (with 4 towers) gives an Adjusted Clean element ∆P as
Viscosity of 1,000 SUS follows:
Specific gravity 0.86 Clean Assembly ∆P = ∆P Housing & ∆P Element
400 gpm flow Clean ∆P = 400 gpm x 0.01 = 1.0 psid
Low pressure drop essential 4 towers
10 µm Optimicron® filter element Clean ∆Padj. = 1.0 x 1000 x 0.86 = 7.09 psid
141 0.86
Clean Assembly ∆P = 6.7 psid + 7.09 psid = 13.8 psid
housing elements
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Notes
A B A B
A B
NF 1354/2654 UHE
NF 1350/2650
NF 32
1354/2654 Stage
STAGE
2 STAGE NF 1354/2654NF UHE 3 Stage
1354/2654 3 STAGE
AA B B A B
↑ ↓
A
B
NF 5254 2 STAGE UHE
NF 1354/2654 3 STAGE
NF 5250 UHE 2 Stage
NF 5250 2 STAGE UHE NF 5250 UHE 3 Stage
NF 5250 3 STAGE UHE
A B
NF1350 / 1354-XXX ↑ ↑
A
↓ ↑
A ↓ ↓
B A B B
NF1350 / 1354-XX
NF 1350 CCP
Features
• Multi-pass filtration in a single pass!
• Beta efficiency values > 5000 single pass possible
• Conventional NF housings are piped in series to achieve ↑ ↓
multi-levels of filtration in one pass. A
B
24.69
627
14.84
377
OUTLET
SAE DN 100 INLET
4" Flange SAE DN 100
4" Flange
10.45
265.4
9.84
250
5
127
Connector
Length [18.5]
NF 1350:470
[36.02]
NF 2650: 915
Clearance
required
for element
removal
Vent port
G 1/2"
2 Places
10.24
260
Lid top
INLET 27.09
SAE DN 100 NF1350: 688
7.87 [44.37]
4" Flange
200 NF 2650: 1127
OUTLET 0.19
SAE DN 100 5
4" Flange
3.06
77.8
∆P Clogging 2.8 7.6
indicator 5.13 4.92 71 193
port 130.2 125
G 1/2" M16X2 Thru 9.84
2 Places Dirty side drain port 4 Places 250
G 3/4"
2 Places
∆P Clogging
Dirty side drain port indicator
G 3/4" port
2 Places G 1/2"
21.54 2 Places
547
6.69
170
8.15
207
0.53
6.54
13.5 Thru
166 Mounting pattern 8 Places
39.53
1004
14.84 14.84
377 377
10.45
265.4 [18.50]
NF 1350:470
[36.02]
OUTLET 9.84 INLET NF2650: 915
SAE DN 100 250 SAE DN 100 Clearance
4" Flange 4" Flange required
5 for element
127 removal
Vent port
G 1/2"
3 Places
10.24
260
lid top
INLET 27.09
7.87 NF1350: 688
SAE DN 100
4" Flange 200
[44.37]
NF 2650: 1127
0.19
5
3.06
77.8 7.6
Dirty side port 4.92 193
OUTLET G 3/4" 125
3 Places 5.13 9.84
SAE DN 100
4" Flange 130.2 250 2.8
ΔP Clogging
71
indicator
port M16X2 Thru
Dirty side drain port ΔP Clogging
G 1/2" 4 Places G 3/4" indicator
3 Places 3 Places port
G 1/2"
36.38 3 Places
924
6.69
170 8.15
207
0.53
6.54
13.5 Thru
166
Mounting pattern 12 Places
43.94
1116
38.11
968
14.84 Butterfly
377 shuttle valve
Butterfly INLET
shuttle valve
OUTLET
10.45
265.4
16.56 Inlet
5 SAE DN 100
420.5 4" Flange
127
Outlet Connector
SAE DN 100 Length [18.5]
4" Flange NF 1354 :470
[36.02]
NF 2654 : 915
Clearance
required
Vent port for element
G 1/2" removal
2 Places
38.11
10.24 968 11.13
260 282.7
Lid top
7.87 27.09
3.06 200 NF1354: 688
77.8 [44.37]
OUTLET
SAE DN 100 28.19 NF 2654: 1127
4" Flange 716
5.12
ΔP Clogging 130 7.6
indicator 5.91 11.63 193
port M16X2 Thru 150 295.5
G 1/2" 4 Places 2.8
2 Places INLET Dirty side drain port 71
SAE DN 100 G 3/4"
Dirty side drain port 4" Flange 2 Places
G 3/4" ΔP Clogging
2 Places indicator
port
21.54 G 1/2"
547 2 Places
6.69 8.15
170 207
2.5 6.54
63.5 MIN 166 0.53
Mounting pattern 13.5 Thru
Vertical offset of
customer mounting 8 Places
feature to clear
butterfly valves
INLET
[18.50]
NF 1354 :470
[36.02]
NF 2654 : 915
OUTLET INLET Clearance
required
for element
removal
OUTLET
[27.09]
NF1354: 688
[44.37]
NF 2654: 1127
OUTLET 7.6
193
Δ 2.8
indicator
INLET ΔP Clogging 71
Dirty side drain port indicator
G 3/4" port
3 Places G 1/2"
3 Places
feature to clear
42.36
1076
34.49
876
14.84
377
25.66
652 11.81
300 [36.02]
915
Clearance
required
for element
OUTLET INLET removal
SAE DN 100 SAE DN 100
4" Flange 4" Flange
Vent port
G 1/2" 10.24
4 Places 260
Lid top
3.06
77.8
7.87 44.37
200 1127
OUTLET
SAE DN 100
4" Flange
5.12
130
11.81
300
0.53
13.5 Thru
6.54
16 Places
166
Mounting Pattern
57.2
1453
49.33
1253
14.84
377
25.66
652 11.81
300 [36.02]
915
Clearance
required
for element
OUTLET INLET removal
SAE DN 100 SAE DN 100
4" Flange 4" Flange 10.24
Vent port 260
G 1/2" Lid top
6 Places
3.06
77.8
7.87
200 44.37
1127
OUTLET
SAE DN 100
4" Flange
5.12
130
7.6
INLET 0.19
193
SAE DN 100 5
0.75 4" Flange 2.8
19 Dirty side drain port 9.84
G 3/4" 71
Thru 250
8 Places
8 Places ∆P Clogging ∆P Clogging
indicator indicator
port Dirty side drain port
G 3/4" port
G 1/2" G 1/2"
8 Places 8 Places
36.37 8 Places
923.8
8.15
207 8.14
207
6.69
170
11.81
300
6.54 0.53
166 13.5 Thru
Mounting Pattern 16 Places
Butterfly
Shuttle 21.54
38.11 3.94 547
Valve 968 100
4 Places 8.15 6.69
207 170
19.76
501.8 6.54
166
11.81 37.29
6.89 300 947
175 Envelope 5.28
4.93 6.54
134
125.3 166
5.91 0.53
150 13.5 thru
24 Places
9.91
251.7 2 Mounting Pattern
21.55 50.8 MIN
547.2 Vertical offset of
customer mounting
feature to clear
butterfly valves
10.45
50.03 265.4
1271 6 Places
Envelope 4" SAE
Code 61 flange
7.87
200 OUTLET
45.89
1165.7 6 Places
3.94
100
2 Places
2.95
5.12
75
130
2 Places
4.72
9.91 120 0.59
3.06 0.55
251.7 TYP 15
77.8 14
14.84 11.63 Places 12 Places
377 295.5
2
38.11 50.8
968 See mounting
45.98 pattern detail
4" SAE 1168
Code 61 flange
INLET
38.11 3.94
968 100 21.54
547
Butterfly
Shuttle 8.15 6.69
0.53
207 170
Valve 13.5 thru
6 Places 24 Places
6.54
27.56 166
700
23.62
600 5.28
6.54 134
166
11.81
6.89 300 30.16
175 766
6.54
49.11 166
1247
5.91 Envelope
150
4.93 9.91
125.3 251.7 2
Mounting Pattern
21.55 50.8 MIN
547.2 Vertical offset of
customer mounting
feature to clear
butterfly valves
10.45
50.03 265.4
1271 6 Places
Envelope 4" SAE
Code 61 flange
7.87
200 OUTLET
45.89
1165.7 6 Places
3.94
100
2 Places
5.12 2.95
130 75
2 Places
4.72
9.91 120 0.59
3.06 0.55
251.7 TYP 15
77.8 14
14.84 11.63 Places 12 Places
377 295.5
2
38.11 50.8
968 See mounting
45.98 pattern detail
4" SAE 1168
Code 61 flange
INLET
8.15
207
36.38
924 6.69
170
8.15
207
49.11
1247
Envelope
2
50.8 MIN
6.89
175 Vertical offset of
customer mounting
feature to clear
9.26 butterfly valves
Butterfly 235
shuttle valve Mounting Pattern
6 places
10.45
265.4
9 Places
50.03 4" SAE
1271 Code 61 flange 7.87
Envelope INLET 200
9 Places
45.89 4" SAE
1165.7 0.55
Code 61 flange 14
3.94 OUTLET 12 Places
100
2 Places 0.59
15
5.12 4.72
9.91
130 120
251.7
2 Places 3.06
77.8 5.91 11.81 11.81
11.63 150 300 300
2 Places 14.84 14.84
295.5 377 377 33.46
52.95 850
1345 2
60.83 50.8
1545 See mounting
pattern detail
9.26 21.54
235 547 0.53
6.69 8.15 13.5 thru
170 207 32 Places
6.54
166
4.92
125
5.28
6.54 134
166
60.92
1547 41.97
ENVELOPE 1066
6.54
166
4.92
125 5.28
6.54 134
166
Butterfly 2
shuttle valve 50.8 MIN
8 Places Vertical offset of
9.26 Mounting Pattern customer mounting
235 feature to clear
butterfly valves
10.45
265.4
8 Places
45.89
1165.7 7.87
4" SAE 200
Code 61 flange 8 Places
50.03
1271 INLET 4" SAE
Envelope Code 61 flange
3.94
100 OUTLET
4 Places 0.59
4.72
15
120
0.55
5.12 5.91 11.81 11.81 11.81
9.91 14
130 150 300 300 300
3.06 251.7 16 Places
4 Places
77.8
4 Places 11.63 14.84 47.26
295.5 377 1200.5
38.11 2
968 50.8
45.98 See mounting
1168 pattern detail
Dimensions:
NF 10454 - 3 Stage UHE (with butterfly valves showing)
36.38
924
9.26 8.15 8.15
235 207 207 0.53
6.69 6.69
13.5 thru
170 170
48 Places
6.54
166
4.92
60.92 125 5.28
1547 6.54
134
Envelope 166
41.97
1066
6.54
4.92
166
125
5.28
134
9.26
235 6.54
Butterfly 166
shuttle valve 2
8 Places 50.8 MIN
Vertical offset of
customer mounting Mounting Pattern
feature to clear
butterfly valves
10.45
265.4
12 Places
7.87
200
45.89
12 Places
1165.7 4" SAE
Code 61 flange 4" SAE
50.03 INLET Code 61
1271 flange
Envelope 3.94 OUTLET
100
0.59 4.72
4 Places 15 120
5.12
130 5.91 11.81 11.81 11.81 0.55
3.06
4 Places 150 300 300 300 14
77.8
16 Places
4 Places 11.63 14.84 14.84 47.26
295.5 377 377 1200.5
52.95
1345 2
50.8
60.83
See mounting
1545
pattern detail
NF 1350, 1354, 2650, 2654 UHE - 2 STAGE HOUSING NF 1350, 1354, 2650, 2654 UHE - 3 STAGE HOUSING
Q in l/min Q in l/min
0 300 600 900 1200 1500 1800 0 300 600 900 1200 1500 1800
18 1.2 25
1.6
15 1.0 20
12 1.2
0.8
15
9 0.6 0.8
10
6 0.4
5 0.4
3 0.2
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
NF 5250, 5254 UHE - 2 STAGE HOUSING NF 5250, 5254 UHE - 3 STAGE HOUSING
Q in l/min Q in l/min
0 300 600 900 1200 1500 1800 0 300 600 900 1200 1500 1800
6 0.4 8
0.5
5
0.3 6 0.4
4
0.3
3 0.2 4
2 0.2
0.1 2
1 0.1
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
B
A
A
NFD 1350-2650 UHE 3 Stage NFD 5250 UHE 3 Stage
B
NFD2650-XX
(2 Stage)
B
NFD1350-XXX
(3 Stage)
A
A
Features
• Multi-pass filtration in a single pass!
• Beta efficiency values > 5000 in a single pass are possible
• Conventional NF housings are piped in a series to achieve
multi-levels of filtration in one pass. Technical Specifications
Note: This filter is configured with an …..R…. type (return/low pressure)
element, so if the filter requires a bypass, the bypass is located in the Mounting Method See drawings
closed end cap of the cartridge element. Port Connection 4” SAE DN 102 Flange Code 61
(with M16 bolts included)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
22.04 32.28
560 820
Top of lid
14.45
R367
14.84
15.14 377 15.14
384.5 384.5
[36.02] 53.97
915
Clearance 1371
required
Vent port for element
10.24 G 1/2" removal
260 4 places
Lid top
[24.09]
NF 1350: 612
7.87 [41.38]
200 NF 2650: 1051
[27.64]
NF 1350: 702
[44.92]
NF 2650: 1141
0.75
3.06
19 5.12 Dirty side ΔP Clogging
77.8 drain port indicator
Thru 130
G 1/2" port G 1/2"
0.53 8 Places 8 places
13.5
Thru 6.54
16 Places 166
6.69
170
21.54
547
22.04
559.8
28.58
726
Mounting Pattern
68.83
1748.2
OUTLET
49.33 4" SAE-DN 100
1253 FLANGE
INLET
4" SAE-DN 100
FLANGE
22.04
559.8 32.49
825.2
14.45
R367
[36.02] 15.14
915 15.14
Vent port Clearance 384.5 384.5
G 1/2 required
6 places for element 14.84 14.84
removal 377 377
10.24
260
[24.09]
7.87 NF 1350: 612
200 [41.38]
NF 2650: 1051
[27.64]
NF 1350: 702
[44.92]
NF 2650: 1141
0.75
5.12 3.06 ΔP Clogging
19 indicator port
130 77.8
Thru G 1/2
12 places
6.54
166 Drain
dirty side
6.69 G 1/2"
170 12 places
0.53
13.5
36.38 Thru
924 16 Places
11.81 INLET
300 SAE-DN 100 OUTLET
4" flange SAE-DN 100
4" flange
60.48 11.02
1536.2 280
11.81 14.45
300 R367
[36.02]
915
Clearance 53.98
Vent port required 1371.2
G 1/2" for element
10.24 8 places removal
260
Lid top
7.87
200 41.38
1051
44.92
1141
0.75
19 5.12 3.06 ∆P Clogging
Thru 130 77.8 indicator
port
52.2 G 1/2"
5.28 1326 16 places
6.54
134 Dirty side
15.51 166
drain port
394 G 1/2"
16 places
21.54
547
0.53
6.69
13.5
170
32 places
Mounting Pattern
Size 5250
Weight (lbs.) 906.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
11.81
300
OUTLET
61.59 INLET SAE-DN 100
1564.4 11.02 SAE-DN 100 4" flange
280 4" flange
11.81 14.45
300 R367
68.58
[36.02]
915 1741.9
10.24 Clearance
260 Vent port required
Lid Top G 1/2" for element
8 places removal
41.32
1049.4
7.87
200 44.92
1141
0.75 3.06
5.12
19 77.8 ∆P Clogging
130 indicator
THRU
52.2 port
1326 G 1/2"
5.28 33.86 6.54 24 places
134 860 166
Dirty side
drain port
G 1/2"
24 places
22.99
584
36.38
924
0.53
13.5
6.69 Bottom Pattern 48 pls
170
Size 5250
Weight (lbs.) 1207.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
NFD 1350-2650 UHE - 2 STAGE HOUSING NFD 1350-2650 UHE - 3 STAGE HOUSING
Q in l/min Q in l/min
0 300 600 900 1200 1500 1800 0 300 600 900 1200 1500 1800
30 2.0 40
2.5
24 32
1.5 2.0
18 24
1.5
1.0
12 16 1.0
0.5
6 8 0.5
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
NFD 5250 UHE - 2 STAGE HOUSING NFD 5250 UHE - 3 STAGE HOUSING
Q in l/min Q in l/min
0 300 600 900 1200 1500 1800 0 300 600 900 1200 1500 1800
18 1.2 20
1.3
15 1.0 16
1.0
12 0.8
12
0.8
9 0.6
8 0.5
6 0.4
3 4 0.3
0.2
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
A
→
A
→
B
←
B
←
NF 104XX MANIFOLD
NF 104XX Manifold
MODULAR Modular
NF 104XX MANIFOLD
MODULAR
A
→
A
→
B
←
B
←
Replacement Element Model Code (ON, ECON2) Clogging Indicator Model Code
2600 R 005 ON / V B6 . VM 5 BM . X / .
Size Indicator Prefix
2600 VM = ∆P, G 1/2” 3000 psi
VD = ∆P G 1/2” 6000 psi
Filtration Rating (micron) (2.0 ver. - LE Indicators only)
1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = ECON2 Trip Pressure
Element Media 2 = 29 psid (2 bar) (return filters)
ON, ECON2 5 = 72 psid (5 bar) (optional)
Seals Type of Indicator
(omit) = Nitrile rubber (NBR) (standard) A = No indicator, plugged port
BM = Pop-up indicator (manual reset)
V = Fluorocarbon elastomer (FKM) C = Electric switch - SPDT
EPR = Ethylene Propylene rubber (EPDM) D = Electric switch and LED light - SPDT
Bypass Valve LE = Electric switch and pop-up
(omit) = 43 psid (3 bar) (standard) B1 = 14.5 psid (1 bar) Modification Number
B6 = 87 psid (6 bar) KB = no bypass
Supplementary Details
Supplementary Details Seals
SO263 = (See above) SFREE = (See above) (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM)
EPR = Ethylene Propylene rubber (EPDM)
Replacement Element Model Code (ECOmicron-fit) Light Voltage (D type indicators only)
1.14.39D 6 ECON2 - V. L24 = 24V L110 = 110V
Size Thermal Lockout (VM type C, D, J, J4 only)
1.14.39D T100 = Lockout below 100˚F
Filtration Rating (micron) Underwriter’s Approval (VM type C, D, J, J4 only)
3, 6, 12, 25 = ECON2 cRUus = Electrical Indicator with underwriter’s recognition
Element Media (For additional details and options, see Clogging Indicators section.)
ECON2
Seals
(omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
23.32
592.3
[36.02]
915 28.18
Clearance required 716
for element removal
10.24 Manual vent
260 valves Option
G 1/2" ports
Lid Top 2 places
52.68
1338
INLET
Filling connection SAE DN100
port 4" Flange
G 3/4"
2 places
Drain
manifold
(Option)
15.96 5.12
405.5 130 Isolation valve
OUTLET
Bolt
Spacing OUTLET
SAE DN100
4" Flange
3.94 13.21
∆ P Clogging indicator 25.66
100 335.5
port 652
G 1/2"
17.81 2 places Dirty side drain port
452.3 G 1/2"
11.81
300 4.72
120
0.55
14
Thru Mounting pattern
4 Places
Size 5210
Weight (lbs.) 287
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
23.32
592.3
[36.02] 28.18
10.24 915 716
260 Clearance required
Lid top for element removal Manual vent
valves Option
G 1/2" ports
2 places
68.11
1730
7.87
3.06 200
77.8
0.75
Connection for static 19
clogging indicator Thru
G 1/2" Isolation valve
8 places 60.78 INLET
2 places 1543.8
INLET
Filling connection SAE DN100
port 4" Flange
G 3/4"
2 places Drain
manifold
(Option)
15.96 5.12
405.5 Isolation valve
130
OUTLET
Bolt
Spacing OUTLET
SAE DN100
4" Flange
25.66
3.94 13.21 652
100 335.5 ∆ P Clogging indicator
port
G 1/2" Dirty Side
17.81 2 places Drain Port
452.3 G 1/2"
11.81
300 4.72
120
Size 5214
Weight (lbs.) 291
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
23.32
592.3
[36.02] 42.67
915 1084
Clearance required
10.24 for element removal
260
Lid Top
Manual vent
valves Option
(G 1/2" ports)
(3 places)
60.08
1526
3.06
Connection 77.8
for static
clogging
indicator
0.75
G 1/2"
3 places 19
Thru 7.87
Isolation valve 200
8 places INLET
Filling connection
port 52.69 INLET
G 3/4" 1338.3 SAE DN100
3 places 4" Flange
Drain
manifold
(Option)
15.96 5.12 Isolation valve
405.5 130 OUTLET
Bolt OUTLET
Spacing SAE DN100
4" Flange
3.94 13.21
100 335.5 ∆ P Clogging indicator 34.24
port 869.7
17.81 G 1/2"
3 places Dirty Side
452.3 Drain Port
G 1/2"
11.81 13.7
300 348
0.55
14 4.72
thru Mounting pattern 120
6 places
Size 7810
Weight (lbs.) 370
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
23.32
592.3
[36.02] 42.67
915 1084
Clearance required
10.24 for element removal
260
Lid Top
Manual vent
valves Option
(G 1/2" ports)
(3 places)
60.08
1526
3.06
Connection 77.8
for static
clogging
indicator
0.75
G 1/2"
3 places 19
Thru 7.87
Isolation valve 200
8 places INLET
Filling connection
port 52.69 INLET
G 3/4" 1338.3 SAE DN100
3 places 4" Flange
Drain
manifold
(Option)
15.96 5.12 Isolation valve
405.5 130 OUTLET
Bolt OUTLET
Spacing SAE DN100
4" Flange
3.94 13.21
100 335.5 ∆ P Clogging indicator 34.24
port 869.7
17.81 G 1/2"
3 places Dirty Side
452.3 Drain Port
G 1/2"
11.81 13.7
300 348
0.55
14 4.72
thru Mounting pattern 120
6 places
Size 7814
Weight (lbs.) 380
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
23.32
592.3
51.22
1301
[36.02]
915 Manual vent
Clearance required valves Option
10.24 for element removal (G 1/2" ports)
260 (4 places)
Lid top
3.06 60.08
77.8 1526 7.87
200
Connection for static 52.69
clogging indicator 0.75 1338.3
G 1/2" 19
4 places
Thru
8 places
Filling connection Isolation valve
port INLET
G 3/4" INLET
4 places SAE DN100
4" Flange
15.96 5.12 Drain
405.5 130 manifold
(Option)
Bolt
Spacing Isolation valve
OUTLET
OUTLET Dirty Side
3.94 SAE DN100 Drain Port
100 4" Flange G1/2"
13.21
335.5 49.28
∆ P Clogging indicator
port 1251.8
17.81
G 1/2"
452.3 4 places
11.81
300
11.81
300
11.81
300
4.72
Mounting pattern
0.55 120
14
Thru
8 Places
Size 10410
Weight (lbs.) 554
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
23.32
592.3
51.22
1301
[36.02]
10.24 915 Manual vent
260 Clearance required valves Option
Lid top for element removal G 1/2" ports
4 places
3.06
68.11 7.87
77.8
1730 200
Connection for static
clogging indicator 0.75
G 1/2" 19
4 places
Thru
8 places
Filling connection Isolation valve
port 60.78 INLET
G 3/4" INLET
4 places 1543.8
SAE DN100
4" Flange
15.96 5.12 Drain
405.5 manifold
130 (Option)
Bolt
Spacing Isolation valve
OUTLET
OUTLET
3.94
SAE DN100
100 4" Flange
13.21
335.5 49.28
∆ P Clogging indicator
17.81 port 1251.8
452.3 G 1/2" Dirty Side
4 places Drain Port
G 1/2"
11.81
300
11.81
300
11.81
300
[36.02]
915
Manual vent Clearance required
valves Option for element removal
(G 1/2" ports)
(2 places)
Isolation valve
INLET
INLET
Connection 6" ANSI CS
for static 64.83 300 lb flange 51.8
clogging 1646.7 1315.7
indicator G 1/2" Drain
2 places manifold
60.59 (Option)
1539
Filling
connection 18.94
(G 3/4" ) 481
2 places
∆ P Clogging indicator
port G 1/2"
(2 places)
15.39
391 Isolation valve 25.84
OUTLET
29.27 656.4 OUTLET
743.4 6" ANSI CS
29.98 300 lb flange
761.5
M16 X 2
1.5 Threaded
38.1 Typ
1.5 4
38.1 101.6
1.5
12.12 38.1
307.8
13.62
345.9
Mounting Pattern
Size 5210DC7
Weight (lbs.) 530
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
5.9
150
[36.02]
10.24 915
260 Manual vent Clearance
Lid top valves Option required
G 1/2" ports for element
3 places removal
58.54
1487
7.87
200 Isolation valve
Connection INLET
INLET 51.8
for static 6" ANSI CS
clogging 1315.7
300 lb flange
indicator G 1/2"
3 places
Drain
64.79 Filling manifold
1645.7 connection Option 18.94
G 3/4" OUTLET 481
3 places 6" ANSI CS
300 lb flange
Isolation valve
OUTLET
Dirty Side
Drain Port ∆ P Clogging 6.25
G 1/2" indicator
16.18 158.8
3 Places port G 1/2"
411 (3 Places)
39.76
30.05 1009.8
763.4
∆ P Clogging indicator
port G 1/2"
(3 places)
M16 X 2
1.5 Threaded
38.1 Typ
4
11.81 11.81 101.6
300 300 1.5
38.1
25.12
638.1
Mounting Pattern
Size 7810DC7
Weight (lbs.) 679
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
NF 330/500/750 HOUSING
Q in l/min
0 100 200 300 400 500
0.8
10
0.6
8
6 0.4
4
0.2
2
0 0
0 20 40 60 80 100 120 140
Q in gpm
2.0 0.1
0.1 1.0
1.0 0.05
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
0 0 0 0
0 100 200 300 400 500 0 100 200 300 400 500
Q in gpm Q in gpm
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Notes
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
B1 B1
B
H1
Clearance
required for
element removal
Vent port
G 1/2"
D H
Max.
∆P clogging
INLET indicator
port
G 1/2”
Dirty side
H3 Drain
G 1/2"
OUTLET
H4
H5
Clean side drain H2 D1
G 1/4"
A
Weight
Size A B B1 H H1 H2 H3 H4 H5 D D1
(lbs)
RFL [7.56] [8.78] [5.23] [24.09] [16.54] [2.66] [9.05] [2.44] [4.19] [6.77]
M16 84.9
851 192 266 133 612 420 67.5 230 61.9 106.4 172
RFL [8.78] [11.26] [5.63] [27.99] [19.69] [3.05] [9.84] [3.06] [5.13] [8.66]
M16 122.4
1301 223 286 143 711 500 77.5 250 77.8 130.2 220
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 25 50 75 100 125 150 175 200 225 0 50 100 150 200 250 275 300
Q in gpm Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0850 R XXX ECON2 0.082 0.055 0.038 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
FI FI
B B
Technical Specifications
Mounting ounting holes on opposite side from Inlet/Outlet
M
Method port faces
Port
Flange ports with metric threads
Connection
111 1” SAE DN 25 Code 61
241 1 1/2” SAE DN 38 Code 61
331 1 1/2” SAE DN 38 Code 61, 2” SAE DN 51 Code 61
501 1 1/2” SAE DN 38 Code 61, 2” SAE DN 51 Code 61
Features 661 2” SAE DN 51 Code 61, 2 1/2” SAE DN 64 Code 61
3” SAE/DIN DN 76 Code 61
• Inlet and outlet connections are located on the same side of
851 2” SAE DN 51 Code 61, 2 1/2” SAE DN 64 Code 61
the transfer valve. Inlet on top and the outlet on bottom.
3” SAE/DIN DN 76 Code 61
• Transfer valve and pressure equalization line allows easy 951 3” SAE/DIN DN 76 Code 61, 4” SAE/DIN DN 102
changeover between filter housings without costly 1301 Code 61
system shutdown. (standard with 851, 951 & 1301) 3” SAE/DIN DN 76 Code 61, 4” SAE/DIN DN 102
• Clogging indicators have no external dynamic seal. High Code 61
reliability is achieved and magnetic actuation eliminates a
leak point. Flow
Inlet: Front Top Outlet: Front Bottom
Note: This filter is configured with an …..R…. type (return/low pressure)
Direction
element, so if the filter requires a bypass, the bypass is located in the Construction Materials
closed end cap of the cartridge element. Head, Lid,
Ductile iron
Elbow
Flow Capacity
111 29 gpm (110 lpm)
241 63 gpm (240 lpm)
331 87 gpm (330 lpm)
501 132 gpm (500 lpm)
661 174 gpm (660 lpm)
851 225 gpm (850 lpm)
951 251 gpm (950 lpm)
1301 343 gpm (1300 lpm)
Housing
111 - 241 501 - 1301
Press. Rating
Max. Allowable
Working
Pressure 580 psi (40 bar) 360 psi (25 bar)
Applications Fatigue 580 psi (40 bar) 360 psi (25 bar)
Pressure >2320 psi (160 bar) >1440 psi (100 bar)
Burst Pressure
Element Collapse Pressure Rating
ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, AM, P/HC 145 psid (10 bar)
Automotive Gearboxes Industrial Power Fluid Temp.
14°F to 212°F (-10°C to 100°C)
Generation Range
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Pulp & Paper Railways Shipbuilding Steel / Heavy Indicator Trip Pressure
Industry
∆P = 29 psid (2 bar) -10% (standard)
∆P = 72 psid (5 bar) -10%
Bypass Valve Cracking Pressure
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10%
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
9.69
246
7.2
R183
H1
Clearance
required
A B1
for element
removal
Vent plug
G 1/2"
∆P Clogging
indicator
port
G 1/2"
H4
H H2
INLET
OUTLET
D3 X T2
H5 2 Mounting holes
D4 D2
B D1
8 PL'S Drain Drain
(Clean side) (Dirty side)
11.54
293
Wt.
Size A B B1 H H1 H2 H4 H5 D1 D2 D3 D4 T2
(lbs)
RFLD 111 [9.17] [2.06] [6.18] [10.35] [6.89] [1.03] [0.98]
[3.15] 80 [3.15] 80 G 1/4 G 1/4 M12 M10 37.4
EAI (DN 25) 233 52.4 157 263 175 26.2 25
RFLD 241 [11.89] [2.75] [6.57] [12.28] [8.27] [5.51] [1.41] [0.71]
[3.74] 95 G 1/4 G 1/4 M12 M12 59.4
EAK (DN 40) 302 69.8 167 312 210 140 35.7 18
RFLD 331 [14.96] [3.06] [7.36] [12.72] [7.87] [4.33] [6.50] [1.69] [0.71]
G 1/2 G 1/4 M12 M12 81.4
DAL (DN 50) 380 77.8 187 323 200 110 165 42.9 18
RFLD 501 [14.96] [3.06] [7.36] [15.75] [11.02] [4.33] [6.50] [1.69] [0.71]
G 1/2 G 1/4 M12 M12 85.8
DAL (DN 50) 380 77.8 187 400 280 110 165 42.9 18
RFLD 661 [19.52] [3.50] [9.92] [18.58] [13.39] [4.33] [6.50] [2.00] [0.71]
G 1/2 G 1/4 M12 M12 162.8
DAM (DN 65) 496 88.9 252 472 340 110 165 50.8 18
RFLD 851 [19.52] [4.19] [8.74] [25.59] [16.54] [9.06] [9.06] [2.44] [0.91]
G 1/2 G 1/4 M12 M16 193.6
DAS (DN 80) 496 106.4 222 650 420 230 230 61.9 23
RFLD 951 [21.57] [4.19] [8.74] [23.43] [14.57] [9.06] [9.06] [2.44] [0.91]
G 1/2 G 1/4 M12 M16 231
DAS (DN 80) 548 106.4 222 595 370 230 230 61.9 23
RFLD 1301 [21.85] [5.13] [9.76] [29.37] [19.29] [9.84] [9.84] [3.06] [0.91]
G 1/2 G 1/4 M16 M16 275
DAT (DN 100) 555 130.2 248 746 490 250 250 77.8 23
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0110 R XXX ON 1.224 0.719 0.487 0.296 0.234 0.178
0240 R XXX ON 0.571 0.284 0.201 0.125 0.101 0.077
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0500 R XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
0660 R XXX ON 0.196 0.093 0.066 0.037 0.031 0.025
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
0950 R XXX ON 0.131 0.057 0.043 0.026 0.021 0.017
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0240 R XXX ECON2 0.340 0.209 0.143 0.099
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0500 R XXX ECON2 0.165 0.104 0.071 0.044
0660 R XXX ECON2 0.104 0.066 0.044 0.027
0850 R XXX ECON2 0.082 0.055 0.038 0.022
0950 R XXX ECON2 0.066 0.044 0.027 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
Vent port
G 1/2"
2.42
b1
61.3
h7
Clearance
d3 required
for element
removal
h5
d2
∆P clogging
indicator
port
h1
G 1/2”
INLET
h4
h2
OUTLET
h3
Drain port
G 1/2"
0.87
22
b2
d1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Flange Use
Size b1 b2 d1 d2 d3 h1 h2 h3 h4 h5 h7 Wt. (lbs)
Port Bolt
5/8”-11
2” ANSI [16.22] [10.24] [9.84] [8.63] [13.39] [38.72] [14.57] [10.47] [9.45] [15.12] [19.69] UNC
141/172
150 lb RF 412 260 250 219.1 340 972 370 266 240 384 500 HEAVY
RFL 1300 HEX
DIN DN [16.22] [10.24] [9.84] [8.63] [13.39] [38.72] [14.57] [10.47] [9.45] [15.12] [19.69]
141/172 M16X2
50 412 260 250 219.1 340 972 370 266 240 384 500
[38.72] [15.12] [19.69] 5/8”-11
3” ANSI [16.22] [10.24] [9.84] [8.63] [13.39] 972 [14.57] [10.47] [9.45] 384 500 UNC
148/178
150 lb RF 412 260 250 219.1 340 [55.75] 370 266 240 [32.44] [37.01] HEAVY
1416 824 940 HEX
[38.72] [15.12] [19.69]
DIN DN [16.22] [10.24] [9.84] [8.63] [13.39] 972 [14.57] [10.47] [9.45] 384 500
148/178 M16X2
80 412 260 250 219.1 340 [55.75] 370 266 240 [32.44] [37.01]
RFL 1416 824 940
1300/1320 [38.72] [14.25] [19.69] 5/8”-11
4” ANSI [16.22] [10.24] [9.84] [8.63] [13.39] 972 [14.57] [9.96] [10.83] 362 500 UNC
152/183
150 lb RF 412 260 250 219.1 340 [55.75] 370 253 275 [31.57] [37.01] HEAVY
1416 802 940 HEX
[38.72] [14.25] [19.69]
DIN DN [16.22] [10.24] [9.84] [8.63] [13.39] 972 [14.57] [9.96] [10.83] 362 500
152/183 M16X2
100 412 260 250 219.1 340 [55.75] 370 253 275 [31.57] [37.01]
1416 802 940
DIN DN [18.90] [10.24] [9.84] [8.63] [13.39] [55.75] [14.57] [8.46] [11.46] [32.44] [37.01]
RFL 1320 192 M16X2
125 480 260 250 219.1 340 1416 370 215 291 824 940
[38.98] [4.72] [16.54] 5/8”-11
3” ANSI [18.35] [12.28] [9.84] [10.50] [14.17] 990 [8.66] [15.28] [16.14 120 420 UNC
160/192
150 lb RF 466 312 250 273 360 [54.33] 220 388 410 [20.08] [31.89] HEAVY
1380 510 810 HEX
[38.98] [4.72] [16.54]
DIN DN [18.35] [12.28] [9.84] [10.50] [14.17] 990 [8.66] [15.28] [16.14] 120 420
160/192 M16X2
80 466 312 250 273 360 [54.33] 220 388 410 [20.08] [31.89]
1380 510 810
[41.34] [9.29] [16.54] 5/8”-11
4” ANSI [18.35] [12.28] [9.84] [10.50] [14.17] 1050 [8.66] [17.24] [11.97] 236 420 UNC
167/199
150 lb RF 466 312 250 273 360 [56.69] 220 438 304 [24.65] [31.89] HEAVY
1440 626 810 HEX
[41.34] [9.29] [16.54]
RFL DIN DN [18.35] [12.28] [9.84] [10.50] [14.17] 1050 [8.66] [17.24] [11.97] 236 420
167/199 M16X2
2500/2520 100 466 312 250 273 360 [56.69] 220 438 304 [24.65] [31.89]
1440 626 810
[41.34] [6.30] [16.54]
DIN DN [18.35] [12.28] [9.84] [10.50] [14.17] 1050 [8.66] [17.24] [14.96] 160 420
176/208 M16X2
125 466 312 250 273 360 [56.69] 220 438 380 [21.65] [31.89]
1440 550 810
[41.34] [6.89] [16.54] 3/4”-10
6” ANSI [18.35] [12.28] [9.84] [10.50] [14.17] 1050 [8.66] [17.24] [14.37] 175 420 UNC
185/217
150 lb RF 466 312 250 273 360 [56.69] 220 438 365 [22.24] [31.89] HEAVY
1440 565 810 HEX
[41.34] [6.89] [16.54]
DIN DN [18.35] [12.28] [9.84] [10.50] [14.17] 1050 [8.66] [17.24] [14.37] 175 420
185/217 M20X2.5
150 466 312 250 273 360 [56.69] 220 438 365 [22.24] [31.89]
1440 565 810
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print..
INLET OUTLET
Vent plug
G 1/2"
h7
Clearance required
for element removal
∆P Clogging
indicator h5
port
G 1/2"
h6
d2 h4
INLET
G 1" h1
Drain port
(dirty side)
h3 OUTLET
h2
G 1"
Drain port
d1 (clean side)
0.87
22
d4
b1 0.59
15 Approx.
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
1700 R XXX ON 0.074 0.035 0.029 0.015 0.014 0.01
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0850 R XXX ECON2 0.082 0.055 0.038 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
1700 R XXX ECON2 0.038 0.027 0.016 0.011
2600 R XXX ECON2 0.022 0.016 0.011 0.005
FI FI
B B
Port Connections
Filter Ball Valve Segment / Butterfly Valve
Size ANSI SAE DN DIN DN SAE/DIN DN DN
1300 2” 50 – – –
1320 3”, 4” – 125 80, 100 –
2500 3”, 4” – 125, 150 80, 100 150
2520 5”, 6” – 125, 150, 200 80, 100 150
4000/4020 4”, 6”, 8 – 125, 150, 200 100 150, 200
5200/5220 4”, 6”, 8 – 125, 150, 200 100 150, 200, 250
6500/6520 4”, 6”, 8 – 125, 150, 200 100 150, 200, 250
7800/7820 4”, 6”, 8 – 125, 150, 200 100 150, 200, 250
15000/15020 – – – – 150, 200, 250
19.29
490
H6
12.48
R317
H7
Clearance
required 36.55
for element 928.4
removal
B1±5
H5 ∆P Clogging D2 INLET
indicator
port
G 1/2"
H1
H4
H2
H3
OUTLET
Drain G 1/2"
(Dirty side)
D3
Use bolts: M20 OR 3/4"
B3
B4±5
B2±5
Foot Pattern
Notes
21.46
545
H6
12.48
R317
H7
Clearance required
for element removal
37.37
949.2
∆P Clogging
H5 indicator INLET
port
G 1/2"
D2
H4
Drain G1"
(Dirty side)
OUTLET
H1
H3
Drain G1"
H2 (Clean side)
D3
Use bolts: M20 OR 3/4"
B4
B2±5 B3
Foot Pattern
Notes
[28.86]
733
Vent plug
G 1/2"
H6
R317
H7
Clearance
required
for element
removal
INLET
∆ P Clogging
indicator
port
G 1/2" H5
D2
Drain G1"
(Dirty side
H4
H1
H3
OUTLET
H2 Drain G1"
(Clean side)
D3
D1±5
Foot Pattern
H8
[26.14]
664
Vent plug
G 1/2" H6
Indicator port
G1/2
H7
Clearance
required
for element
removal
INLET
D2 H5
Drain G1"
H1
(Dirty side) H4
H3
OUTLET
Can be turned
through
H2
180
Drain port
(Clean side)
G1"
D1±5
D3
Foot Pattern
Size 2500 2520 4000 4020 5200 5220 6500 6520 7800 7820 15000 15020
Weight (lbs.) 632.8 721 866.5 1111.2 2107.7 2464.8 2471.4 2826.4 2489.1 2861.6 3278.3 3578.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
H8
32.7
830.7
Vent plug
G 1/2"
H6
∆P Clogging R317
indicator
port
G 1/2"
H7
Clearance
required
for element
removal
INLET
D2 H5
Drain G1"
(Dirty side)
H1
H4
H3
OUTLET
H2
Drain G1"
(clean side)
D1±5
D3
Foot Pattern
Size 4000 4020 5200 5220 6500 6520 7800 7820 15000 15020
Weight (lbs.) 866.5 1111.2 2107.7 2464.8 2471.4 2826.4 2489.1 2861.6 3278.3 3578.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Notes
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
1700 R XXX ON 0.074 0.035 0.029 0.015 0.014 0.01
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0850 R XXX ECON2 0.082 0.055 0.038 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
1700 R XXX ECON2 0.038 0.027 0.016 0.011
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
INLET
HF4RL 09: [9.80]
249 6.60
HF4RL 18: [19.13]
486 167.6
HF4RL 27: [28.50]
724
Clearance required
for element removal 5.21
132.4
4.63
117.6
∆P Indicator Port
G 1/2"
5.20
132.1
5.70 7.00
0.44 144.8 177.8
11.2
Thru
4 pl's
5.63
143
Size 09 18 27
Weight (lbs.) 10.7 33 45.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
HF4RL Housing
30 2.0
25
1.5
20
15 1.0
10
0.5
5
0 0
0 10 20 30 40 50 60 70 80 90 100
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
2.07
52.5
3/4"-16UNF
3.31 SAE-8 Port
84 or
1/2" Bspp
INLET & OUTLET 1.18
∆P clogging 0.28
indicator 30
port 7 0.75 0.55 0.83
G 1/2" 19 14 21
1.30
33
1.34
3.31 34
OUTLET Inlet 84
6.06
LPF 35: 154
[6.89]
LPF 55: 175
1.06 2.69
SW 27 68.2
Hex [3.35]
85 3.23
Clearance required 82
for element removal
Size 35 55
Weight (lbs.) 2.3 2.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
INLET/OUTLET øD Depth T
SAE-20 3/8-24 UNF-2B [0.551]
G 1-1/4 (BSPP) M10 x 1.50 14
2.20
Mounting Holes 56
DXT
2 Places
4.25
108
5.12
130
∆ P clogging
indicator
2.09 port
53 0.24 G 1/2"
6
1-5/8-12UNF3
SAE-20 Port
or G1/4"
4.43 Inlet & Outlet
112.5
9.21
LPF 160: 234
[11.3]
LPF 240: 287
[18.58]
LPF 280: 472
1.06
3.75 27
95.2 HEX
[3.35]
85 Clearance required
for element removal
8.7 0.6 10
5.8 0.4 0.5
5
2.9 0.2
0 0 0 0
0 2.0 5.0 7.9 10.6 13.2 15.9 18.5 0 20 40 60 80 100
Q (gpm) Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
d1 b5
b2 b3
b4
b1 (NPT)
d3 x t1
(4 Places)
h3 b1
h2
OUTLET INLET
h1
d2
h4
Clearance required d3* - UN Threads for SAE & NPT Ports
SW
for element removal - M. Threads for BSPP Ports
b1
Size b1 b2 b3 b4 b5 d1 d2 d3* h1 h2 h3 h4 SW t1 HEX
(NPT)
(2.72) (4.84) (1.42) (1.77) (1.18) (1.062) (2.64) (2.05) 10-32UNF-2B (6.16) (1.22) (2.95) (0.94) (1.125)
30 (0.28) 7 (0.24) 6
69 123 36 45 30 27 67 52 M5 X 0.8 156 31 75 24 28.6
(3.54) (5.80) (1.89) (2.20) (1.26) (1.126) (3.31) (2.68) 1/4-28UNF-2B (6.95) (1.54) (2.95) (1.06) (1.38)
60 (0.24) 6 (0.35) 9
90 147.2 48 56 32 28.6 84 68 M6 X 1.0 176.5 39 75 27 34.93
(3.54) (5.80) (1.89) (2.20) (1.26) (1.126) (3.31) (2.68) 1/4-28UNF-2B (9.68) (1.54) (2.95) (1.06) (1.38)
110 (0.24) 6 (0.35) 9
90 147.2 48 56 32 28.6 84 68 M6 X 1.0 246 39 75 27 34.93
(4.92) (7.67) (2.56) (3.35) (1.38) (1.376) (4.57) (3.74) 3/8-24UNF-2B (9.29) (1.81) (3.74) (1.26) (0.55) (2.00)
160 (0.24) 6
125 194.9 65 85 35 34.95 116 95 M10 X 1.5 236 46 95 32 14 50.8
(4.92) (7.67) (2.56) (3.35) (1.38) (1.376) (4.57) (3.74) 3/8-24UNF-2B (11.67) (1.81) (3.74) (1.26) (0.55) (2.00)
240 (0.24) 6
125 194.9 65 85 35 34.95 116 95 M10 X 1.5 296.5 46 95 32 14 50.8
(4.92) (7.67) (2.56) (3.35) (1.38) (1.376) (4.57) (3.74) 3/8-24UNF-2B (18.98) (1.81) (3.74) (1.26) (0.55) (2.00)
280 (0.24) 6
125 194.9 65 85 35 34.95 116 95 M10 X 1.5 482 46 95 32 14 50.8
(6.26) (9.07) (3.35) (4.53) (2.36) (1.406) (6.3) (5.12) 1/2-20UNF-2B (11.90) (1.97) (4.13) (1.42) (0.67) (2.25)
330 (0.24) 6
159 230.4 85 115 60 35.71 160 130 M12 X 1.75 302.5 50 105 36 17 57.15
(6.26) (9.07) (3.35) (4.53) (2.36) (1.406) (6.3) (5.12) 1/2-20UNF-2B (18.40) (1.97) (4.13) (1.42) (0.67) (2.25)
660 (0.24) 6
159 230.4 85 115 60 35.71 160 130 M12 X 1.75 467.5 50 105 36 17 57.15
P in psid
8 8
6 0.41 6 0.41
4 4
2 0.13 2 0.13
0 0 0 0
0 3 6 9 12 0 5 10 15 20 25 30
Flow in gpm Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
"D" Pressure Elements ...D…BH4HC (Betamicron High Collapse) Wire Mesh ...D…W/HC Elements (Low Collapse)
Size 3 µm 5 µm 10 µm 20 µm Size 25, 50, 100, 200 µm
0030 D XXX BH4HC 5.005 2.782 1.992 1.043 0030 D XXX W/HC 0.166
0060 D XXX BH4HC 3.216 1.789 0.993 0.670 0060 D XXX W/HC 0.042
0110 D XXX BH4HC 1.394 0.818 0.489 0.307 0110 D XXX W/HC 0.023
0160 D XXX BH4HC 0.922 0.571 0.324 0.241 0160 D XXX W/HC 0.016
0240 D XXX BH4HC 0.582 0.373 0.214 0.159 0240 D XXX W/HC 0.010
0280 D XXX BH4HC 0.313 0.187 0.099 0.088 0280 D XXX W/HC 0.005
0330 D XXX BH4HC 0.423 0.247 0.154 0.110 0330 D XXX W/HC 0.008
0660 D XXX BH4HC 0.181 0.104 0.055 0.049 0660 D XXX W/HC 0.004
0.67 1.06
17 27
2.52
64
5.67
143.9
4.49
∆P clogging indicator 114
0.24 port G 1/2”
6
0.79
20
INLET OUTLET
13.17
LPFH 325: 334.5
[16.70]
LPFH 425: 424.2 1-7/8-12UN-2B
SAE-24 PORT OR
1-1/2 BSPP PORT
INLET AND OUTLET
11.12 10.92
LPFH 325: 282.5 LPFH 325: 277.5
[14.65] [14.46]
LPFH 425: 372.2 LPFH 425: 367.2
8.19
LPFH 325: 208
[11.72]
LPFH 425: 297.7
4.00 0.3
0.2
2.00
0.1
0 0
0 20 40 60 80 100 120
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron ...D...ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0325 D XXX ON 0.444 0.204 0.150 0.081 0.070 0.056
0425 D XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
Betamicron ...D...BH/HC
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0325 D XXX BH/HC
Consult factory upon request
0425 D XXX BH/HC
All Element K Factors in psi / gpm.
Railways
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
OUTLET
0.94
1.38
24
35.1
4.00
101.6
1.61
INLET 41
Mounting Holes 1.38
4 Places 35.1
3.54
90
VLXBF.0
Right or left
side as option
9.37
MFX 100: 238 3/4" or 1"
[12.83] INLET and OUTLET
MFX 200: 326 Port
0.94
[1.58] 24 HEX
4.00
60 3.29
Clearance required 101.6
84
for element Bottom of
removal bowl
20 SAE-12, G 3/4"
SAE-16, G 1" 1.2
15
0.8
10
0.4
5
0 0
0 10 20 30 40 50 60
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
(From Tables Below) 141 SUS 0.86
ECOmicron …MX…ECON2
Size 3 μm 5 μm 10 μm 20 μm
0100 MX XXX ECON2 0.713 0.549 0.357 0.263
0200 MX XXX ECON2 0.439 0.324 0.209 0.154
Mobilemicron …MX…MM
Size 8 μm 10 μm 15 μm
0100 MX XXX MM 0.148 0.148 0.121
0200 MX XXX MM 0.088 0.088 0.071
OUTLET
INLET
2.73 1.77
← 1/2" Port
69.3 45 4 Places
1.18
30
1.50
38
2.99
76
0.94
HEX 24
Size 30
Weight (lbs.) 5.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
c1
d1 b3 b2
c2
d5 x †2
b4 Flange
2 Places
b1
h2
OUTLET INLET
h1
d2
Optional G 1/2"
Drain Port
h4 HEX
Clearance
required
for element
removal
Notes
b2 b3
b1
OUTLET b4 INLET
d1
b1
c1 G 1/2"
0.24 Indicator Port d3
Indicator
6 G 1/2" 2 Places d5 x t2 Port
h2 c2
OUTLET INLET Inlet
h1
h1 d2
d2
4.41
112
HEX 5.98
G 1/2" G 1/2"
h4 Drain Port Drain Port 152
Clearance required
for element removal
d3
Size b1 b2 b3 b4 c1 c2 d1 d2 NOM d4* d5 h1 h2 h4 HEX †1 †2
660...F... (6.3) (5.24) (4.53) (2.36) (6.42) (5.12) 1- (18.93) (2.05) (4.53) (1.42) (0.67)
- - - -
1.X 160 133 115 60 163 130 1/2" 1/2- 481 52 115 36 17
20UNF- 2B 3/4-
660...L... (6.3) (5.24) (4.53) (2.36) (3.81) (1.75) (6.42) (5.12) M12x1.75 10UNC- 2B (18.93) (2.05) (4.53) (1.42) (0.67) (0.98)
2"
1.X 160 133 115 60 96.8 44.5 163 130 481 52 115 36 17 25
M20x2.5
660...F... (6.3) (5.24) (4.53) (2.36) (6.42) (5.12) 1- (18.54) (2.05) (13.78) (1.42) (0.67)
- - - -
2.X 160 133 115 60 163 130 1/2" 1/2- 471 52 350 36 17
20UNF- 2B 3/4-
660...L... (6.3) (5.24) (4.53) (2.36) (3.81) (1.75) (6.42) (5.12) M12x1.75 10UNC- 2B (18.54) (2.05) (13.78) (1.42) (0.67) (0.98)
2"
2.X 160 133 115 60 96.8 44.5 163 130 471 52 350 36 17 25
M20x2.5
1320...F... (6.3) (5.24) (4.53) (2.36) (6.42) (5.12) 1- (29.25) (2.05) (26.38) (1.42) (0.67)
- - - -
2.X 160 133 115 60 163 130 1/2" 1/2- 743 52 670 36 17
20UNF- 2B 3/4-
1320...L... (6.3) (5.24) (4.53) (2.36) (3.81) (1.75) (6.42) (5.12) M12x1.75 10UNC- 2B (29.25) (2.05) (26.38) (1.42) (0.67) (0.98)
2"
2.X 160 133 115 60 96.8 44.5 163 130 743 52 670 36 17 25
M20x2.5
h4
Clearance
[0.39] required for
1.42 HEX 10 element removal 5.98
Vent Port 152
HEX 36 G1/2"
5.87
149
1.26
SAE- 32 Flange 5.20
Code 62 (2") 132
h1
1.75
44.5 INLET
OUTLET
2.05
52 HEX 8 Drain Port
G3/8"
[1.06] ∆ P Clogging
HEX 27 3.81 0.24 6.30 Indicator Cavity
6 G 1/2"
96.8 160
1-7/8-12UN-2B
SAE-24 Port
M12X22/27
0.40
deep 10.2
2.36
Threaded Port
60
Size h1 h4
4.53
330...F..3.X [10.35] [3.15]
115
330...L..3.X 263 80
6.42 660...F..3.x [16.85] [9.84]
163 660...L..3.x 428 250
1320...F..3.x [29.49] [22.44]
1320...L..3.x 749 570
9 9
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
0.6 0.6
6 0.4 6 0.4
3 0.2 3 0.2
0 0 0 0
0 3 6 9 12 0 5 10 15 20 25 30
Q (gpm) Q (gpm)
DF 160/240/280 Housing DF 330/660/1320 Housing
Q (l/min) Q (l/min)
0 50 100 150 200 250 300 350 0 100 200 300 400 500 600 700
15 15
1.0 1.0
0.8 0.8
10 10
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
0.6 0.6
0.4 0.4
5 5
0.2 0.2
0 0 0 0
0 20 40 60 80 100 0 40 80 120 160 200
Q (gpm) Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Wire Mesh …D…W/HC Elements Metal Fiber …D…V Elements (High Collapse)
Size 25, 50, 100, 200 µm Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX W/HC 0.166 0030 D XXX V 1.011 0.740 0.411 0.200
0060 D XXX W/HC 0.042 0060 D XXX V 0.877 0.511 0.296 0.183
0110 D XXX W/HC 0.023 0110 D XXX V 0.452 0.304 0.182 0.118
0160 D XXX W/HC 0.016 0160 D XXX V 0.251 0.177 0.123 0.079
0240 D XXX W/HC 0.010 0240 D XXX V 0.169 0.137 0.093 0.062
0280 D XXX W/HC 0.005 0280 D XXX V 0.126 0.093 0.064 0.041
0330 D XXX W/HC 0.008 0330 D XXX V 0.121 0.097 0.065 0.043
0660 D XXX W/HC 0.004 0660 D XXX V 0.063 0.050 0.034 0.021
1320 D XXX W/HC 0.002 1320 D XXX V 0.032 0.026 0.018 0.012
All Element K Factors in psi / gpm.
Filter
Bypass
Element
Valve
Pop-up
Indicator
OUTLET
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
0.98 0.24
25 6
3.81 6.93
96.8 176
1.75 5.28
44.5 134
Mounting Pattern
OUTLET
3.86 3.86 3.81
4.33 98 98 96.8 2.36 G 1/2"
110 2.13 60 Indicator
54 INLET 1.75 Port
44.5
Mounting
Surface SAE 6000PSI
DN 50
M12x1.75 M20x2.5
x 22 DP x 30 DP
INLET
34.76
883
6.00
152.4
4.80
122
36 HEX G 1/2"
Drain Port
6.93
[27.56] 176
700
Clearance required
for element removal
6.93
176
G 1/2"
Vent Port HEX 36
4.80
122
6.00
152.4 34.76
883
M12x1.75
x 22 DP M20x
2.13 2.5x30 DP Inlet
54
OUTLET
INLET
1.75
44.5
0.98 0.24
25 6
1.06
27
2.13
54
7.72
196
0.24 3.81
6 Indicator Port 96.8
G 1/2"
1.75
44.5
M20x2.5
x 30 DP
2.36
60
OUTLET INLET
INLET
34.76
883
6.00
152.4
4.80
122
36 HEX
G1/2"
Drain Port
[27.56] 6.93
700 176
Clearance required
for element removal
4.88
124
34.29
871
6.00
152.4
INLET OUTLET
M20x2.5
1.75
x 30 DP
44.5
3.81
0.24
96.8 G 1/2" Indicator
6 Port
7.72
196
2.13
Threaded Version
54 1.06
HEX 27
5.28 6.93
134 176
M12x1.75
x 23 DP
2-1/2"-12UN-2B IN. 4.33
Mounting Pattern 110
SAE 32 Port
2 Places
Size DF/DFF 1500 3.0 “T”
Weight (lbs.) 152.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Railways
2.05 3.39
52 86
0.84
21.4 ∆ P Clogging
Indicator Port
G 1/2
4.02
102
3.13
79.4
0.24
6
INLET OUTLET
3.86
98
1.00
25.4
[0.95]
3.00 HEX
24
76.2
[2.96]
75
Clearance required
for element removal
Size 04 08
Weight (lbs.) 10.7 14.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
[1.75] [0.17]
44.5 4.3
[1.25±0.01]
[0.34]
31.8±0.2
4X Ø8.6 HOLES
THRU
[3.43]
Ø87
[0.69]
Ø17.5 [0.69]
INLET [0.63] [1.25±0.01]
Ø17.5 15.9 31.8±0.2
OUTLET
[4.09]
104
[1.02] [4.09]
26 104
[3.78]
96 Δ CLOGGING
INDICATOR PORT
G 1/2”
[8.34]
HF2P-04 212
[12.01]
HF2P-08 305
[0.95]
24
HEX
[3.00]
Ø76.2
Size 04 08
Weight (lbs.) 10.7 14.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Q in l/min
0 20 40 60 80 100
14 1.2
12
10 0.8
8
6
4 0.4
2
0.0
0 5 10 15 20 25
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
6.30 6.42
160 163
Flange
HF3P-16
2.05 0.24
52 6 ∆P Clogging 6.30
Indicator ∆P Clogging
160 Indicator
Port G 1/2"
Port G 1/2"
Outlet Inlet
[10.00]
HF3P-04 254 5.12
[13.74] 130
HF3P-08
349
18.98 22.40
HF3P-13 HF3P-16 569
482.1
5.12
130
4.41
1.42 112
HEX 36 Drain Port
G 1/2"
[4.53]
115 Drain Port
Clearance required G 1/2"
for element removal
1.42 [16.81]
HEX 36 427
5.98 Clearance
152 required for
element
removal
Size 04 08 13 16
Weight (lbs.) 49.2 56.1 72.5 107.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
5.75
146
5.25
133.4
[12.00]
HF4P-09
305
[21.00]
HF4P-18
533
[30.00]
HF4P-27
762
Clearance required
for element removal
0.88
22.4
Vent Plug
SAE-4
(7/16-20UNF)
HF4P-09
[16.33]
415
HF4P-18
[25.62]
651
HF4P-27
[35.00]
∆ P Clogging 889
indicator port
G 1/2"
1.38
35
2.75
69.9
b
5.00
Flange
a b c d 127
Details
a
Code (1.406) (2.750) 1/2-13UNC (1.06)
61 35.7 69.8 27
Code (1.437) (3.125) 5/8-11UNC (1.38) 38.1
62 36.50 79.38 35 c x d DP
4.50 SAE Flange
114.3
Size 09 18 27
Weight (lbs.) 69.9 98.4 132.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
0.88
22
HF4P-09
[16.30]
414
HF4P-18
[25.59]
650
HF4P-27
[34.98]
888
Drain Plug
SAE 8
(3/4"-16UNF)
1.38
35
2.75
69.9
∆P Clogging
6.25 0.58 Indicator Port
G 1/2"
159 15
0.56
14
Mounting
holes Through
4 Places
4.50
114.3
2.25
57.2
0.81
20.6 OUTLET
[1.25]
2.00 32
50.8
INLET
5.00 [1.25]
127 32
Size 09 18 27
Weight (lbs.) 71.7 100.2 134.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
2.17
55
Mounting Holes
3/8-16 UNC-2B x 12 DP
4 Places INLET
1.57 3.54
40 90
OUTLET
∆ P Clogging 1.01
Indicator Port 25.7
G 1/2
HEX 27
3.62
0.24 92
6
1.38
35
3.54
90
[6.30]
Size 35 160
[8.11]
Size 55 206
10.20 3.00
Size 75 259 76.2
[11.77]
Size 95 297
0.94
HEX 24
[2.91]
74 3.39
Clearance Required 86
for Element Removal
Size 35 55 75 95
Weight (lbs.) 8.2 9.3 10.4 11.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
1.26
0.93
32
23.5
55°
OUTLET INLET
Mounting Holes
3/8-16UNC-2B
3 Places
3.62
92
∆P Clogging
Indicator Port
G1/2
1.38 HEX 27
35
3.54
90
[6.30]
Size 35 160
[8.11]
Size 55 206
10.20 3.00
Size 75 259 76.2
[11.77]
Size 95 297
0.94
HEX 24
3.39
[2.91] 86
74
Clearance Required
for Element Removal
Size 35 55 75 95
Weight (lbs.) 8.2 9.3 10.4 11.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Q in l/min
0 10 20 30 40 50 60 70 80 90 100
25.0 1.72
20.0 1.38
15.0 1.03
10.0 0.69
5.0 0.34
0.0 0.00
0 3 5 8 11 13 16 18 21 24 26
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
2.20
3.86 2.01 2.20 2.20 56
98 51 56 56
0.75
[0.33]
19
5/16-24UNF-2B x 8.5 DP [0.43]
Mounting holes M6 x 1.0 x 11 DP 0.35
1.26 4 Places Mounting Holes 9
32 4 Places
0.24 ∆P Clogging
6 Indicator Port
G 1/2 Inlet
HEX 27
1.38
35
4.21
107
10.67
HFM 75 271
[12.24] 3.00
HFM 95 311 76.2
0.94
HEX 24
[2.95]
75
Clearance required
for element removal
Size 75 95
Weight (lbs.) 12.4 13.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Q in l/min
0 20 40 60 80 100 120 140
10.1 0.7
8.7 0.6
7.2 0.5
5.8 0.4
4.3 0.3
2.9 0.2
1.4 0.1
0.0 0.0
0 5.3 10.6 15.8 21.1 26.4 31.7 37.0
Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
VA
INLET
-LDE
1 5/8"-12UN-2B
SAE-20
OR 11.02
-LDF
1 7/8"-12UN-2B 280 LDK
SAE-24 1.97 [11.10]
OR 50 282 LDE/LDF
-LDK
1 1/2" SAE DN 38
Flange
INLET AND OUTLET
FMND 160: INLET OUTLET
12.20
310
FMND 250:
[15.75]
400
FMND 400: 4.13
105 4.17
[21.65] 106
550
[3.35] 5.12
85 130
Clearance required
2.75 for element removal
69.9
[1.26]
32
0.75 HEX
1.41
M12 X 1.75 X 19 DP
35.7 Flange
LDK Version 4 Places
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
FMND 160/250/400 LDK [0.75] FMND 160/250/400 LDF FMND 160/250/400 LDE
[2.75] M12X1.75X19 DP
69.9
[1.41]
35.7
1-7/8"-12UN-2B 1-5/8"-12UN-2B
SAE-24 Port SAE-20 Port
INLET & OUTLET INLET & OUTLET
Flange SAE (1 1/2" Flanged)
DN38 3000 PSI
INLET & OUTLET
B B
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
b4
b11
b8
b9 INLET
d1
Vent Plug G1/8
Dirty Side
220.3
b14 b13
b2 b7 b1 b12
0.24 SQ1
6
OUTLET
d2
h2 h1
h5 h7 MAX h4
h6
d4 x t1
h3
HEX 1
d3 HEX 2
h9 b5 drain
G 1/2" Drain
b6
h8
Clearance Required
for Element Removal
b1 [5.43] 138 [5.43] 138 [7.48] 190 [7.48] 190 [7.48] 190
b2 [6.69] 170 [6.69] 170 [8.27] 210 [8.27] 210 [8.27] 210
b6 [4.78] 121.5 [4.78] 121.5 [6.20] 157.5 [6.20] 157.5 [6.20] 157.5
b10 [1.91] 48.5 [1.91] 48.5 [2.07] 52.5 [2.07] 52.5 [2.07] 52.5
b13 (≈) [5.91] 150 [5.91] 150 [7.60] 193 [7.60] 193 [7.60] 193
b14 (≈) [7.13] 181 [7.13] 181 [8.70] 221 [8.70] 221 [8.70] 221
d1*
1-1/16-12UN-2B 1-7/8-12UN-2B
SAE-12 SAE-24
d2*
d3 [2.69] 68.2 [2.69] 68.2 [3.75] 95.2 [3.75] 95.2 [3.75] 95.2
d4 1/4-28UNF-2B 3/8-24UNF-2B
h2 [4.61] 117 [4.61] 117 [6.38] 162 [6.38] 162 [6.38] 162
h4 [2.54] 64.5 [2.54] 64.5 [4.17] 106 [4.17] 106 [4.17] 106
h6 [8.07] 205 [10.89] 276.5 [11.20] 284.5 [13.60] 345.5 [20.69] 525.5
h7 (≈) [8.07] 205 [8.07] 205 [9.65] 245 [9.65] 245 [9.65] 245
Dimensions shown are [inches] millimeters for general information and overall envelope size only.
Dirty Side
Vent Plug G1/8 Clean Side
Vent Plug G1/8
12.8
325 ∆P Clogging
0.62 6.89 indicator port
15.7 175 G1/2"
Approx.
Vent Plug
G1/8"
10.63
5.91
270
Lifting holes 150
Approx. [0.67]
1/2-20UNF-2B x 17 DP
2.38
INLET 60.5
Indexing plunger SAE 2"(DN50)
for locking 6000 PSI
the lever
(optional)
0.62
Pressure 15.7 5.39
0.24 Equalization 137
6 Valve 3.27
8.98 83
228
Approx.
3.86
7.87 98
200 SIZE 330
[14.51]
368.5
SIZE 660
[21.18] OUTLET
538 SAE 2" (DN50)
0.31 6000 PSI
8 Mounting
ring size
660 only
INLET / OUTLET
4.69 11.61 0.59 Flange
119 295 15
5.08 0.79 3.81
129 20 96.8
8.23
209 6.69
170
3/4-10UNC-2B x
1.75
[0.98] Min.
44.5
25 Full Thread
4 PL's
0.67 1.42
1/2-20UNF-2B X 17 DP 36 HEX
4 PLS 3.23
82
9.65
245
12.8 ∆P Clogging
325 Indicator Port
0.62 G 1/2"
6.89
15.7
175 Vent plug
Approx.
G1/8"
10.63 5.91
270 Lifting Holes 150
[0.67]
Approx. 1/2-20UNF-2B x 17
DP
2.38
Indexing INLET 60.5
plunger for SAE 2" (DN50)
locking lever 6000 PSI
(Optional)
5.39
137
0.62
15.7
8.98 Pressure
228 equalization
0.24 valve
Approx.
6
3.86
98
7.87
200
4.41
112
INLET / OUTLET
11.61 0.59
Flange 4.69
295 15
119
3.81 5.08 0.79
96.8 129 20
8.23
209
1.75 3/4-10UNC-2B x
44.5 [0.98] Min.
25 Full Thread 6.69
170
0.67 1.42
1/2-20UNF-2B X 17 DP 36 HEX
4 PLS 3.23
82
9.65
245
Size 660 1320
Weight (lbs.) 262.5 335.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Q (l/min) Q (l/min)
0 20 40 60 80 100 0 30 60 90 120 150 180
35 50
2.0
30 3.0
40
25 1.5 2.5
30
ΔP in bar
ΔP in bar
2.0
ΔP in psi
ΔP in psi
20
1.0
15 1.5
20
10 1.0
0.5
10
5 0.5
0 0 0 0
0 10 20 30 0 10 20 30 40 50
Q (gpm) Q (gpm)
DFDK 330 / 660 / 1320 QLL Housing “L” Ball Valve DFDK 330 / 660 / 1320 QTL Housing “T” Ball Valve
Q (l/min) Q (l/min)
0 100 200 300 400 500 600 0 100 200 300 400 500 600 700 800 900
30 35
2.0
25 30
2.0
1.5 25
20
1.5
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
20
15 1.0
15 1.0
10
10
0.5
0.50
5 5
0 0 0 0
0 20 40 60 80 100 120 140 160 0 50 100 150 200 250
Q (gpm) Q (gpm)
Notes
BY-PASS
VALVES
(OPTIONAL)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
5.63
142.9
1.38
35 OUTLET
INLET
2.63 0.24
66.7 6 ∆ P Clogging
[1.00] Indicator Port
1/2"-13UNC-2B x 25.4 DP G 1/2"
4 Places
1.85
47.1
1.25
31.8
SAE 20 Thread or
SAE 20 Flange code
62 (1-1/4")
[9.68]
DFFH 160 246
12.05
DFFH 240 306
[19.17]
DFFH 280 487
(Optional) 1.26
Drain Port HEX 32
G 1/2"
3.75
[3.35] 95.2
85
Clearance required
for Element Removal
6.3
[0.67] 160
1/2-20UNF-2B IN. x 17 DP
2.36 SAE Ported Version
60
1-7/8-12UNC
SAE-24 PORT
OUTLET
INLET 0.71
(Filtered 18
Flow)
DFFH 660 & 1320 2.X
[0.95] Two Piece Bowl
3/4-10UNC-2B x 24 DP
4 Places
0.24 0.24
6 3.81 6
∆P Clogging 96.8
Indicator Port
G 1/2"
2.39 2.39
60.7 60.7
1.75
44.5
6.98
177.4
SAE 24 Thread
Or SAE 32 flange
[13.19] code 62 (2") 19.57
DFFH 330 335 DFFH 660 497
19.88 [32.28]
DFFH 660 505 DFFH 1320 820
5.2
132
4.41
112
Mounting holes
11.1 0.55
∆ P Clogging
Indicator Port 282 3/8-24UNF-2B x 14
0.56 0.56 8 Places
G 1/2"
2 Places 14.2 14.2
3.35 4.57
85 116
1.67
0.69 5.47 5.63 42.5
18 139 142.9
1.38
35
16.73
425 0.24
6
1.85
47
9.68
DFFHM 160 F 246
[12.05]
DFFHM 240 F 306
[19.17]
DFFHM 280 F 487
A1
A3
Flange bolt holes
(4 Places)
Size A1 A2 A3
A2
DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP
4.53 6.26
115 159
Inlet
1.18 2.26
30 6.77 6.3 57.5
172 160
2.36
60
0.24
19.37 6
492
2.39
60.7
[13.19]
DFFHM 300 335
[19.88]
DFFHM 660 505
1.42
Drain Port HEX 36 5.13
G 1/2"
130.2
[3.74]
95
Clearance required
A1 for element removal
A3
Flange bolt holes
(4 Places)
Size A1 A2 A3
A2 DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP
19.37
492 Flange Detail
13.07 3/4-10UNC-2B x 1.97
332 0.94 50
24 DP
1.18
30 6.77 6.30 2.26 3.81
172 160 57.5 96.8
2.36
60
[0.24]
6
Indicator Port 2.39
G 1/2" 60.7
32.26
819.4
5.20
132
4.41
112
[26.38]
670
Clearance Required
for Element Removal
DFFH 160/240/280 Forward Flow DFFH 330/660/1320 Forward Flow DFFHM 160/240/280 Forward & Reverse Flow
40 20.0 150
30 15.0
100
20 10.0
50
10 5.0
0 0.0 0
0 20 40 60 80 0 20 40 60 80 100 0 20 40 60 80
Flow in gpm Flow in gpm Flow in gpm
DFFH 160/240/280 Reverse Flow DFFH 330/660/1320 Reverse Flow DFFHM 330/660/1320 Forward & Reverse Flow
40 20.0 50
40
30 15.0
30
20 10.0
20
10 5.0
10
0 0.0 0
0 20 40 60 80 0 15 30 45 60 75 90 0 50 100 150
Flow in gpm Flow in gpm Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Drain Port
G 1/2" DF60-280 [2.95] DF 30 QE DF 60/110 QE
G 1/4" DF30 DF 30/60/110 75 [2.64] [3.31]
(Optional SO184) [3.35] 67 84
DF 160/240/280 85 DF 160/240/280 QE
Clearance required [4.57]
for element removal 116
[0.94]
DF30 QE 24
[1.06]
HEX DF60/110 QE 27
[1.26]
DF 160/240/280 QE 32
Indicator Port
G 1/2"
5.51
140
3.13
3.74 0.16 79.5
OUTLET 95 4
2.28 2.05
58 52
0.91
23
INLET 14.06
DF 330 QE 357
DF 660 QE [20.70]
526
Drain Port
G 1/2" (Standard) 5.12
130
[4.53]
115
Clearance required 6.06
for element removal 154
1.42
HEX 36
6.06
154
6.16
5.51
156.5
140 0.16
4 3.13 ∆ P Clogging
3.74
2.05 79.5 Indicator Port
95 G 1/2"
52
2.28
58
[20.31]
DF 660 QE 516
32.99
DF 1320 QE 838
5.2
132
4.41
112
Drain Port
5.98 G 1/2"
152 [13.82]
351 DF 660 QE
[25.59]
650 DF1320 QE
Clearance required
for elemental removal
1.42
HEX 36
18 1.2
6 0.4
12 0.8
3 0.2
6 0.4
00 0.0 0
4 8 12 16 0 3 6 9 12 15 18
Q in gpm Q in gpm
0.4 1.4
5.0 18
0.3 1.2
0.2 9
2.5 0.8
0.1
0.4
0 0
0 6 12 18 24 30 36 42 0 22 44 66 88 110 132
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Metal Fiber ...D…V Elements (High Collapse) Wire Mesh ...D…W/HC Elements (Low Collapse)
Size 3 µm 5 µm 10 µm 20 µm Size 25, 50, 100, 200 µm
0030 D XXX V 1.011 0.740 0.411 0.200 0030 D XXX W/HC 0.166
0060 D XXX V 0.877 0.511 0.296 0.183 0060 D XXX W/HC 0.042
0110 D XXX V 0.452 0.304 0.182 0.118 0110 D XXX W/HC 0.023
0160 D XXX V 0.251 0.177 0.123 0.079 0160 D XXX W/HC 0.016
0240 D XXX V 0.169 0.137 0.093 0.062 0240 D XXX W/HC 0.010
0280 D XXX V 0.126 0.093 0.064 0.041 0280 D XXX W/HC 0.005
0330 D XXX V 0.121 0.097 0.065 0.043 0330 D XXX W/HC 0.008
0660 D XXX V 0.063 0.050 0.034 0.021 0660 D XXX W/HC 0.004
1320 D XXX V 0.032 0.026 0.018 0.012 1320 D XXX W/HC 0.002
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
[6.30]
DFP 60 160
[9.06]
DFP 110 230
[7.99]
DFP 160 203
10.35 DFP [2.68]
DFP 240 263 60/110 68.2
[17.48] 3.75
DFP 280 444 DFP 95.2
160/240/280
3.31 2.00
84.1 50.7
0.75
1.66 19
42.1
0.45
0.66 OUTLET 11.5
16.7 1.18 Mounting
30 Holes
6 Places
6.22
158
∆ P Clogging
Indicator Ports
G 1/2"
[13.54] 2 Places
(Both Machined)
DFP 330 344
20.24
DFP 660 514
5.13
130.2
G 1/2"
Drain Plug
[3.74] 1.42
95 HEX 36
Clearance
required for
element
removal
1.66
42.1
OUTLET 0.45
0.66 1.18 11.5
16.7 30 Mounting Holes
6 Places
6.22
158
∆ P Clogging
Indicator Ports
G 1/2"
2 Places
(Both Machined)
[19.80]
DFP 660 503
32.48
DFP 1320 825
5.20
132
4.41
112
5.98 G 1/2"
[13.78] 152 Drain Plug
DFP 660 350
[26.38]
1.42
DFP 1320 670
Clearance HEX 36
required
for element
removal
30 60 30
20 40 20
10 20 10
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Wire Mesh ...D…W/HC Elements (Low Collapse) Metal Fiber ...D…V Elements (High Collapse)
Size 25, 50, 100, 200 µm Size 3 µm 5 µm 10 µm 20 µm
0060 D XXX W/HC 0.042 0060 D XXX V 0.877 0.511 0.296 0.183
0110 D XXX W/HC 0.023 0110 D XXX V 0.452 0.304 0.182 0.118
0160 D XXX W/HC 0.016 0160 D XXX V 0.251 0.177 0.123 0.079
0240 D XXX W/HC 0.010 0240 D XXX V 0.169 0.137 0.093 0.062
0280 D XXX W/HC 0.005 0280 D XXX V 0.126 0.093 0.064 0.041
0330 D XXX W/HC 0.008 0330 D XXX V 0.121 0.097 0.065 0.043
0660 D XXX W/HC 0.004 0660 D XXX V 0.063 0.050 0.034 0.021
1320 D XXX W/HC 0.002 1320 D XXX V 0.032 0.026 0.018 0.012
OUTLET OUTLET
T A P B T A P B T
INLET INLET
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Indicator Port
G 1/2" INLET Face
1.89 B 1.81
48 A 46
T
P
B
A
T
D03 Pattern
0.23
6
0.03 1.59 0.64
0.8 40.5 16.3
0.41
0.209 10.3
5.3 THRU
4 Places 0.75
19
1.09
27.8
Size 30
Weight (lbs.) 5.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Indicator Port
G 1/2" Port
Indicator DF 60 Z DF 110 Z [3.15]
G 1/2" 0.24 [9.88]
DF [12.63]
60 Z DF 110 Z 80
[3.15]
0.24
6 251
[9.88] 321
[12.63] Clearance
80 required
6 251 321 for elementrequired
Clearance removal
for element removal
Indicator Port
(Left Hand Side Version) - (optional) G 1/2" Port
Indicator
G 1/2"
T T
T T
A B
A B
P
P
D05 Pattern
D05 Pattern
D05 Pattern
0.79
0.79
20
20
0.47
0.47
12
12
T T
1.81 T T
1.81
46 1.28
1.28
32.5 A B
46
32.5 A B
P
P
0.84 0.13
0.84 0.13
3.2
21.4
21.4 0.25 3.2
0.66
0.25
6.3 0.66
16.7
6.3 16.7
1.06
1.06
27
27
1.47
1.47
37.3
37.3
2
2
50.8
50.8
2.13
2.13
54
54
Size 60 110
Weight (lbs.) 13.1 15
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
60 80
50
60
40
30 40
20
20
10
0 1 2 3 4 5 6 7 0 5 10 15 20
Q in gpm Q in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
CFxx20 CFxx45
Railways
CFMM20G15W1.0/12 CFW20G25/149W1.0/12
Q in l/min Q in l/min
0 3 6 9 12 15 0 10 20 30 40 50 60
21.0 21.0
18.0 1.3 18.0 1.3
15.0 15.0
ΔP in psid
ΔP in psid
1.0 1.0
ΔP in bar
ΔP in bar
12.0 12.0
0.8 0.8
9.0 9.0
0.5 0.5
6.0 6.0
3.0 0.3 3.0 0.3
CFMM45G15W1.0/12 CFW45G25/149W1.0/12
Q in l/min Q in l/min
0 5 10 15 20 25 30 35 40 45 50 55 0 10 20 30 40 50 60 70 80 90 100110120130
21.0 21.0
18.0 1.3 18.0 1.3
15.0 15.0
ΔP in psid
ΔP in psid
1.0 1.0
ΔP in bar
ΔP in bar
12.0 12.0
0.8 0.8
9.0 9.0
0.5 0.5
6.0 6.0
3.0 0.3 3.0 0.3
6
Ra1 .
1.50" HEX
15°
0.008 +0.012
0.13 - 0.000
R0.2
0.3
3.3+0
3.16 DETAIL Z
80.2 2.63 SCALE 1.5 : 1
67 45°±5°
1.93
49
1.00 Spot Face
25.4 +0.004
1.398 - 0.000
0.1 0.1 A
35.5+0
1-5/16-12UN-2A IN.
Z
Ra1.6
0.79 MIN
[1.18] [1.64] 20 MIN
From 30 to 41
2.24 2.60
57 66 2.70
INLET Min Depth 68.5
of the Fitting
0.75
19
0.008
R0.2
.6
R a1
OUTLET
20°
0.75
19
Pilot Drill
1.003±0.002
0.05 A
25.5±0.1
Ra1.6
Size 20
Weight (lbs.) 0.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
2.00
51 HEX
6
Ra1.
.6
Ra1
20° 15°±1°
+0.012
0.134 - 0.000
0.3
3.4+0
0.008
R0.2
0.008
R0.2
45°
DETAIL X DETAIL Z
3.52 SCALE 4 : 1 SCALE 1.5 : 1
89.4 3.00
76.2
2.283
58
SPOTFACE
1.713±0.004 0.1 A
1.311 43.5±0.1
33.3
1 5/8"-12UN-2B IN.
A
1-5/8"-12UN-2A IN. SAE-20 PORT
0.031 0.1 A
0.8 Z Ra1.6
0.79 MIN
20 MIN
[1.497] [1.969]
2.293 From to
38 50
2.598 58
3.059 66
77.7
INLET
1.00
25.4
OUTLET X
1.187
30.15
MAX
Ra1.6
+0.002
1.313 - 0.000
0.05 A
0.051
33.35+0
Size 45
Weight (lbs.) 0.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Applications
10 µm
60
50
40
30
20
141 µm
10
0
0 4 8 12
Q in gpm
1.5
38.1 HEX
0.49
12.5
Installation Torque:
200 lb – ft into Steel Block
2.29
58.3 155 lb – ft into
Aluminum Block
1.12
28.52
1.93
49
1-5/16-12UN-2A IN.
15°
[ 0.004 A ] 1.4±0.002
35.55±0.05
0.1 A
1-5/16-12UN-2B IN.
0.13 MAX
3.2 MAX A
0.14±0.008
3.5±0.2 1.22
31
[ 0.008 A ]
0.2 A 0.75
19 0.97
1.34 24.6
1.844 MIN 34
46.84 MIN
0.53
13.5
[0.06]
R1.5
0.03
R0.75
0.53
13.5
20°
1.6
+0.002
1.126 - 0.000
[ 0.002 A ]
0.05
0.05 A 28.6+0
Size 40
Weight (lbs.) 0.75
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Replacement Elements
Part Number Description Flow Rate
02069397 0015 D 010 W 0015 - 4 gpm
02069398 0040 D 010 W 0040 - 12 gpm
02069399 0120 D 010 W 0120 - 30 gpm
CP-SAE 15 CP-SAE 40
Q (l/min) Q (l/min)
0 7.57 20.8 33.1 0 18.9 37.8 56.7 75.6
50 3.44 50 3.44
10 µm
40 40
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
30 2.06 30 2.06
10 µm
20 20
75/141 µm 75/141 µm
10 0.68 10 0.68
0 0 0 0
0 2 4 6 8 10 0 5 10 15 20
Q (gpm) Q (gpm)
CP-SAE 120
Q (l/min)
0 37.8 75.6 113.4 151.2
50 3.44
40
10 µm
ΔP in bar
ΔP in psi
30 2.06
20
75/141 µm
10 0.68
0 0
0 10 20 30 40
Q (gpm)
A
A A
Bypass
Valve Assembly
50 P.S.I.D.
Bypass Valve
(Initial Cracking)
C
Filter
Element (10 Micron
Wire Cloth Standard)
OUTLET PORT
D
INLET PORT
Manifold Filter
Cavity Configuration
E SAE Torque
Model A B C D F G H J
O-Ring Port Alu. Steel
1.12/28.4 min 0.781/19.8 min 65 85
CP-SAE 15 1.00/25.4 0.41/10.4 1.75/44.5 0.74/18.8 -10 (7/8-14) 2.41/61.2 0.266/6.8
1.87/47.5 max 0.814/20.7 max ft-lb ft-lb
1.49/37.8 min 1.140/29.0 min 150 200
CP-SAE 40 1.5/38.1 0.5/12.7 2.50/63.5 1.00/25.4 -16 (1 5/16-12) 3.34/84.8 0.531/13.5
2.53/64.3 max 1.1875/30.1 max ft-lb ft-lb
1.92/48.8 min 1.750/44.5 min 230 305
CP-SAE 120 2.13/54.1 0.65/16.5 4.00/101.6 1.50/38.1 -24 (1 7/8-12) 5.01/127.3 0.875/22.2
3.81/96.8 max 1.803/45.8 max ft-lb ft-lb
SET Series –
Manifold Cartridge Filters
Manifold cartridge filters are installed into a threaded cavity that is machined
in the customer’s manifold. More than one SET may be installed in the
manifold, if required for capacity. Cavity drawings are provided for easy
implementation and installation. A SET filter can be provided with an
element or without an element (existing installations). A differential pressure
clogging indicator, to warn of high upstream pressure (element clogged), can
be attached to the manifold as well (indicator cavity drawings available upon
request).
Installation
The NF Set Manifold Cartridge Filter is installed into a threaded cavity
that is machined in the manifold (manifold not included - see cavity
drawing). A bushing is provided for proper element installation, as
well as a bowl with o-ring seal and back-up ring. An element can be
provided as a option. The bushing holds the element in place during
Manifold cavity is only for filtration operation, and facilitates easy removal for element change
representation and not out.
HYDAC’s scope of supply
Features More than one SET may be installed in the manifold if required for
capacity. A differential pressure clogging indicator, to warn of high
• N on-welded housing design reduces stress concentrations and upstream pressure (element clogged), can be attached to the manifold
• prevents fatigue failure. as well (cavity drawings for that upon request). For additional information,
• Aluminum alloy is water tolerant - anodization is not required for contact HYDAC.
water based fluids (HWBF).
• O -ring seals are used to provide positive, reliable sealing. Choice
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene
Technical Specifications
propylene rubber) provides compatibility with petroleum oils, Mounting Method See drawings
synthetic fluids, water-glycols, oil/water emulsions, and high Flow Direction
water based fluids. Element Out-to-in
• Screw-in lid requires minimal clearance to remove the element Construction Materials
for replacement, and contaminated fluid cannot be washed Housing, Lid Aluminum
downstream when element is serviced.
• HYDAC differential Pressure Indicators (optional) have no external Flow Capacity
dynamic seal. This results in a high system reliability due to 1350 343 gpm (1300 lpm)
magnetic actuation, thus eliminating a potential leak point. 2250 396 gpm (1500 lpm)
• For special finishes and coatings – consult HYDAC for minimum 2650 450 gpm (1700 lpm)
quantities, availability and pricing. Housing Pressure Rating
Max. Allowable Working Pressure* 360 psi (25 bar)
Applications Fatigue Pressure 360 psi (25 bar)
Burst Pressure 1754 psi (121 bar)
Element Collapse Pressure Rating (optional)
ON, W/HC 290 psid (20 bar)
ECON2, BN4AM, P/HC, AM 145 psid (10 bar)
V 435 psid (30 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Agricultural Gearboxes Industrial Power
Generation Consult HYDAC for applications below -22˚F (-30˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure (optional)
Pulp & Paper Shipbuilding Steel / Heavy ∆P = 29 psid (2 bar) -10% 1.0 - Static
Industry ∆P = 72 psid (5 bar) -10% 2.0 - Differential
Bypass Valve Cracking Pressure (included when element present)
∆P = 14.5 psid (1 bar) +10%
∆P = 43 psid (3 bar) +10% (standard)
∆P = 87 psid (6 bar) +10%
*Note: All NF…1.0 Filters MAWP reduce to 7 bar (101.5 psi) when using the
following “VMF” and “VR” indicators: B, BM, E, ES, GC, LE, LZ.
6 0
95.38-0.015
L 89.28
1.2X20
200 1.2X20
40
1
R0.3 Bushing detail R0.3
Item 4
(Not supplied by HYDAC)
(LN1 FIT)
7 Torque to
110 LBF-FT
186
1.6
89.28
OUTLET
INLET
20±1.5
Bushing press depth
65
35 41.2 46
Z 0 1.6
31-0.3
+0.02
95.36 0
A
+0.2
190.2 0
0
199.4-0.2 0.05 A
M198 X 3 0.05 A
1.6
Section A-A
45°
30°
R2
R2
1.6
R85.3 R0.5 1.6
7.5 +0.2
6.2 0
R2
R0.2
A A 5
+15°
30° - 0° 1x45
3.2
+0.2
190.2 0
R55.3
+0.3
198.5 0
Detail Z
200
1
Bushing detail
Item 4
(Supplied by HYDAC)
7 Torque to
110 LBF-FT
186
0
86-1
1.6
OUTLET
INLET
+2 +2
23 0 27 0
3.2
41.2 46 55
35
Z 0 1.6
0.1 B 31-0.3
B M95X2
A
+0.2
190.2 0
0
199.4-0.2 0.05 A
M198 X 3 0.05 A
1.6
Section A-A
45°
30° R2
R2
R85.3
R2
1.6
R0.5 1.6
7.5 +0.2
6.2 0
R2
R0.2
A A 5
+15°
30° - 0° 1x45
3.2
R55.3
+0.2
190.2 0
+0.3
198.5 0
Detail Z
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
2200 R XXX ON 0.058 0.027 0.022 0.012 0.011 0.008
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.016
2200 R XXX ECON2 0.029 0.021 0.013 0.008
2600 R XXX ECON2 0.022 0.016 0.011 0.005
Manifold cavity
is only for
representation
and not HYDAC’s
scope of supply
Installation
The LPF Set Manifold Cartridge Filter is installed into a threaded
cavity that is machined in the manifold (manifold not included - see cavity
drawing). A bushing is provided for proper element installation, as
well as a bowl with o-ring seal and back-up ring. An element can be
provided as a option. The bushing holds the element in place during
filtration operation, and facilitates easy removal for element change
out.
Features More than one SET may be installed in the manifold if required for
• N on-welded housing design reduces stress concentrations and capacity. A differential pressure clogging indicator, to warn of high
• prevents fatigue failure. upstream pressure (element clogged), can be attached to the manifold
• Aluminum alloy is water tolerant - anodization is not required for as well (cavity drawings for that upon request). For additional information,
water based fluids (HWBF). contact HYDAC.
• O -ring seals are used to provide positive, reliable sealing. Choice
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene Technical Specifications
propylene rubber) provides compatibility with petroleum oils,
synthetic fluids, water-glycols, oil/water emulsions, and high Mounting Method Threaded bowl
water based fluids. Flow Direction
• Screw-in bowl requires minimal clearance to remove the element Element Out-to-in
for replacement, and contaminated fluid cannot be washed Construction Materials
downstream when element is serviced. Bowl Aluminum Extrusion
• HYDAC differential Pressure Indicators (optional) have no external Flow Capacity
dynamic seal. This results in a high system reliability due to 35 9 gpm (35 lpm)
magnetic actuation, thus eliminating a potential leak point. 55 15 gpm (55 lpm)
• For special finishes and coatings – consult HYDAC for minimum 160 42 gpm (160 lpm)
quantities, availability and pricing. 240 63 gpm (240 lpm)
280 74 gpm (280 lpm)
Applications Housing Pressure Rating
Max. Allowable Working 35 - 55 580 psi (40 bar)
Pressure 160 - 280 725 psi (50 bar)*
*Note: 580 psi (40 bar) when using BF indicator
Fatigue Pressure 35 - 55 580 psi (40 bar) (107 cycles)
160 - 280 725 psi (50 bar) (106 cycles)
35 - 55 Contact HYDAC
Agricultural Automotive Construction Industrial Burst Pressure 160 - 280 > 3625 psi (200 bar)
Element Collapse Pressure Rating (optional)
BH4HC, V 3045 psid (210 bar)
ON, W/HC 290 psid (20 bar)
Fluid Temp. Range -22°F to 212°F (-30°C to 100°C)
Consult HYDAC for applications operating below -22°F (-30°C)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
2 6 1
INLET
27 HEX 68.2
OUTLET
75 min
Clearance required
for element removal
h1
21
1.2 1.2
Item No SET Components
R0.3 R0.3 1 Bowl
Ra 1.6 2 Bowl back-up ring
R0.3 R0.3
3 Bowl o-ring
4 Bushing
Drain plug
20° 20° 5 (Std – sizes 330/660,
20 25.3 r6 Opt – sizes 60-280 - use code SO184)
6 Element (optional)
Ra 1.6
1.6 Ra
Bushing Detail
Item 4
Size h1
Unspecified Tolerances
LPF 35 SET 70.5 From 0.5 3 6 30 120
To 3 6 30 120 400
LPF 55 SET 116.5 ±0.1 ±0.1 ±0.2 ±0.3 ±0.5
Size 35 55
Weight (lbs.) 1 1.6
Dimensions shown are millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
18.5
1.5x45°
R1 X
A
Ra 1.6
M68x2
H7
20 25.3
Ra 1.6 H8
65
Ra
1. 6 20°
0.05 A
1.2
5 MIN
Depth of fit
27
6
Depth of fit
29
+0.3
2.5
0
R1.6
Ra 3.2
30° 30°
1.6
Ra R1.6 Ra
3.2
R0.3 +0.3
68.3
0
Detail X
2 6 1
INLET
27 HEX 68.2
OUTLET
75 min
Clearance required
for element removal
h1
Bushing Detail
Item 4
Secure with Loctite 4204
Torque to 10-2 Nm
Size h1
Unspecified Tolerances
LPF 35 SET 70.5 From 0.5 3 6 30
To 3 6 30 120
LPF 55 SET 116.5 ±0.1 ±0.1 ±0.2 ±0.3
Size 35 55
Weight (lbs.) 1 1.6
Dimensions shown are millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
18.5
1.5x45°
R1 X
A
Ra 1.6
H8
65
14 M22x1.5 LH
M68x2
0.05 A
0.05 A
+1
6 0
27
8
Depth of fit
29
+0.3
2.5
0
R1.6
Ra 3.2
30° 30°
1.6
Ra R1.6 Ra
3.2
R0.3 +0.3
68.3
0
Detail X
85 min
Clearance required
for element removal
h1
2
6 1
INLET
4 86.4
95.2
OUTLET
27 HEX
25
1.2 1.2
Ra 1.6
R0.3 R0.3
Bushing Detail
Item 4
Size h1
35
33 MIN
Depth of fit
29.5
23
2x45°
0,05 A
1.6 20°
Ra
Ra 1.6
H7 +2 H8
33.8 42 92 M95x2
0
Z
Ra 3.2
A
Ra 1.6
+0.8
1.2
- 0.2
Ra 1.6
7 0°-5°
Depth of fit
3.2
0°-5°
Ra
8 32
+0.5
R0.3
0
+0.3
Ra
40 95.3
H9
3.
98.2 R1.6 0
2
45° 60°
Ra 3.2
Ra 1.6
R1.6
R1.6 R0.2 R0.2
R1.6
R1.6
+0.25
4.8 2.5±0.3
0
Detail Z
85 min
Clearance required
for element removal
h1
2
6 1
INLET
4 86.4
95.2
OUTLET
27 HEX
Bushing Detail
Item 4
(Supplied by HYDAC)
Size h1
35
33 MIN
Depth of fit
29.5
23
2x45°
0,05 A
1.6 20°
Ra
Ra 1.6
H7 +2 H8
33.8 42 92 M95x2
0
Z
Ra 3.2
A
Ra 1.6
+0.8
1.2
- 0.2
Ra 1.6
7 0°-5°
Depth of fit
3.2
0°-5°
Ra
8 32
+0.5
R0.3
0
+0.3
Ra
H9 95.3
3.
40 98.2 R1.6 0
2
45° 60°
Ra 3.2
Ra 1.6
R1.6
R1.6 R0.2 R0.2
R1.6
R1.6
+0.25
4.8 2.5±0.3
0
Detail Z
Installation
The LF Set Manifold Cartridge Filter is installed into a threaded cavity
that is machined in the manifold (manifold not included - see cavity
drawing). A bushing is provided for proper element installation, as
well as a bowl with o-ring seal and back-up ring. An element can be
provided as a option. The bushing holds the element in place during
Features filtration operation, and facilitates easy removal for element change
out.
• N on-welded housing design reduces stress concentrations and
• prevents fatigue failure. More than one SET may be installed in the manifold if required for
• Aluminum alloy is water tolerant - anodization is not required for capacity. A differential pressure clogging indicator, to warn of high
water based fluids (HWBF). upstream pressure (element clogged), can be attached to the manifold
• O -ring seals are used to provide positive, reliable sealing. Choice as well (cavity drawings for that upon request). For additional information,
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene contact HYDAC.
propylene rubber) provides compatibility with petroleum oils,
synthetic fluids, water-glycols, oil/water emulsions, and high Technical Specifications
water based fluids.
Mounting Method Threaded bowl
• Screw-in bowl requires minimal clearance to remove the element
for replacement, and contaminated fluid cannot be washed Flow Direction
downstream when element is serviced. Element Out-to-in
• HYDAC differential Pressure Indicators (optional) have no external Construction Materials
dynamic seal. This results in a high system reliability due to Bowl Aluminum Extrusion (sizes 30 - 660)
magnetic actuation, thus eliminating a potential leak point. Steel (size 280)
• For special finishes and coatings – consult HYDAC for minimum Flow Capacity
quantities, availability and pricing. 30 8 gpm (30 lpm)
60 16 gpm (60 lpm)
110 29 gpm (110 lpm)
160 42 gpm (160 lpm)
Applications 240 63 gpm (240 lpm)
280 74 gpm (280 lpm)
330 84 gpm (330 lpm)
660 174 gpm (660 lpm)
Housing Pressure Rating
Max. Operating Pressure 1500 psi (100 bar)
Fatigue Pressure 1500 psi (100 bar)
Agricultural Automotive Construction Industrial Burst Pressure size 30 5510 psi (380bar)
sizes 60 - 660 > 6090 psi (420 bar)
Element Collapse Pressure Rating (optional)
BH4HC, V 3045 psid (210 bar)
ON, W/HC 290 psid (20 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Railways Steel / Heavy Consult HYDAC for applications operating below -22°F (-30°C)
Industry Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected
∆P Indicator Trip Pressure (optional)
∆P = 29 psid (2 bar) -10%
∆P = 72 psid (5 bar) -10%
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
3 6 1 5
INLET
Item No SET Components
1 Bowl
2 Bowl back-up ring
4
d7 3 Bowl o-ring
d1
4 Bushing
Drain plug
5 (Std – sizes 330/660,
OUTLET Opt – sizes 60-280 - use code SO184)
HEX 6 Element (optional)
h2 min
Clearance required for element removal
h1 - SO184 -
h6
1.2 1.2
Ra 1.6
20° 20°
1 .6 Ra
Ra 1. 6
d6 d5 r6
R0.3 R0.3
5 R0.3
R0.3
Bushing Detail
Version with -SO184
Item 4
h1
Size d1 d2 d3 d4 d5 d6 d7 d8 d9 h1 h2 h3 h4 h5 h6 h7 h8 h9 HEX
-SO184
30 52 52 M55x1.5 11.9 11.9 8 44 56 55.2 77.5 80.5 75 33 31 23 18 6 4 5 24
330 130 125 M130x2 47.8 47.8 36 110 131 130.3 165.5 - 105 55 52 41.6 26 10 6 9 36
660 130 125 M130x2 47.8 47.8 36 110 131 130.3 336.5 - 105 55 52 41.6 26 10 6 9 36
Unspecified Tolerances
From 0.5 3 6 30 120
To 3 6 30 120 400
±0.1 ±0.1 ±0.2 ±0.3 ±0.5
h3
h7
h4
h9 h5
20°
1 .6
Ra
0
d4-0.012 d3
Ra 1.6
0
d2-0.018
1.2 Ra 1.6
R1 X
MANIFOLD MACHINING
d5
d5 +0.3
+0.3 d9 0
Ra d9 0 Ra
1.6 R0.3 1.6
R0.3 3.2
3.2 Ra
Ra
30° 30° 30°
30° Ra 3.2
Ra 3.2
+0.3 +0.3
6 0 2.5 0
h5
Ra
+0.3
Ra R0.3 d9 0
1.6 R0.3 3.2
Ra
45°
.5
30° 30°
12
Ra 3.2
Ra
+0.3
4 0 0.5x45°
0 +0.3
39 h8-1 d8 0
6 1 5
d1
HEX
Size d1 d2 d3 d4 d5 d6 d7 d8 d9 h1 h2 h3 h4 h5 h6 h7 h8 h9 HEX
330 130 125 M130x2 47.8 47.8 36 110 131 130.3 165.5 105 55 52 41.6 26 10 6 9 36
660 130 125 M130x2 47.8 47.8 36 110 131 130.3 336.5 105 55 52 41.6 26 10 6 9 36
Unspecified Tolerances
From 0.5 3 6 30 120
To 3 6 30 120 400
±0.1 ±0.1 ±0.2 ±0.3 ±0.5
h7 h3
h4
h9 h5
20°
1 .6
Ra
H7
d4 d3
Ra 1.6
H8
d2
1.2 Ra 1.6
R1 X
h5
h5 +0.3
+0.3 d9 0
Ra d9 0 Ra
1.6 R0.3 1.6
R0.3 3.2
3.2 Ra
Ra
30° 30° 30°
30° Ra 3.2
Ra 3.2
+0.3 +0.3
6 0 2.5 0
h5
Ra
+0.3
Ra R0.3 d9 0
1.6 R0.3 3.2
Ra
45°
.5
30° 30°
12
Ra 3.2
Ra
+0.3
4 0 0.5x45°
0 +0.3
39 h8-1 d8 0
"D" Pressure Elements ...D…BH4HC (Betamicron High Collapse) Wire Mesh ...D…W/HC Elements (Low Collapse)
Size 3 µm 5 µm 10 µm 20 µm Size 25, 50, 100, 200 µm
0030 D XXX BH4HC 5.005 2.782 1.992 1.043 0030 D XXX W/HC 0.166
0060 D XXX BH4HC 3.216 1.789 0.993 0.670 0060 D XXX W/HC 0.042
0110 D XXX BH4HC 1.394 0.818 0.489 0.307 0110 D XXX W/HC 0.023
0160 D XXX BH4HC 0.922 0.571 0.324 0.241 0160 D XXX W/HC 0.016
0240 D XXX BH4HC 0.582 0.373 0.214 0.159 0240 D XXX W/HC 0.010
0280 D XXX BH4HC 0.313 0.187 0.099 0.088 0280 D XXX W/HC 0.005
0330 D XXX BH4HC 0.423 0.247 0.154 0.110 0330 D XXX W/HC 0.008
0660 D XXX BH4HC 0.181 0.104 0.055 0.049 0660 D XXX W/HC 0.004
Installation
Features The LPFH Set Manifold Cartridge Filter is installed into a threaded
• Integrated retrofit protection cavity that is machined in the manifold (manifold not included - see cavity
• Non-welded housing design reduces stress concentrations and drawing). A bushing is provided for proper element installation, as
• prevents fatigue failure. well as a bowl with o-ring seal and back-up ring. An element can be
• Aluminum alloy is water tolerant - anodization is not required for provided as a option. The bushing holds the element in place during
water based fluids (HWBF). filtration operation, and facilitates easy removal for element change
• O -ring seals are used to provide positive, reliable sealing. Choice out.
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene More than one SET may be installed in the manifold if required for
propylene rubber) provides compatibility with petroleum oils, capacity. A differential pressure clogging indicator, to warn of high
synthetic fluids, water-glycols, oil/water emulsions, and high upstream pressure (element clogged), can be attached to the manifold
water based fluids. as well (cavity drawings for that upon request). For additional information,
• Screw-in bowl requires minimal clearance to remove the element contact HYDAC.
for replacement, and contaminated fluid cannot be washed
downstream when element is serviced. Technical Specifications
• HYDAC differential Pressure Indicators (optional) have no external
dynamic seal. This results in a high system reliability due to Mounting Method Threaded bowl
magnetic actuation, thus eliminating a potential leak point. Flow Direction
• For special finishes and coatings – consult HYDAC for minimum Element Out-to-in
quantities, availability and pricing. Construction Materials
Bowl Aluminum Extrusion
Applications Flow Capacity
325 87 gpm (325 lpm)
425 112 gpm (425 lpm)
Housing Pressure Rating
Max. Allowable Working
Pressure 325 - 425 500 psi (34 bar)
Fatigue Pressure 325 - 425 500 psi (34 bar) (10 6 cycles)
Agricultural Automotive Construction Industrial
Burst Pressure 325 - 425 > 2700 psi (186 bar)
Element Collapse Pressure Rating (optional)
ON, W/HC 290 psid (20 bar)
Fluid Temp. Range -22°F to 212°F (-30°C to 100°C)
Consult HYDAC for applications operating below -22°F (-30°C)
Fluid Compatibility
Steel / Heavy
Industry Compatible with all hydrocarbon based, synthetic, water glycwol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected
∆P Indicator Trip Pressure (optional)
∆P = 29 psid (2 bar) -10% (optional)
∆P = 36.25 psid (2.5 bar) (BF indicator)
∆P = 72 psid (5 bar) -10% (standard)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
3 2 1 6 5
INLET
OUTLET
119.5
ITEM 4
PROVIDED
Size L
Unspecified Tolerances
From 0.5 3 6 30 120
325 262 To 3 6 30 120 400
±0.1 ±0.1 ±0.2 ±0.3 ±0.5
425 352
18 MAX 0.1
INLET, DIRTY SIDE
E 140
BOLT CIRCLE
6X M8X1.25 - 6H 16DP
0.8 A B
Ra1.6
B
79±0.2 40
170
EXTENT OF A
FLATNESS AND FINISH
30°
SECTION E-E
E
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron ...D...ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0325 D XXX ON 0.444 0.204 0.150 0.081 0.070 0.056
0425 D XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
Betamicron ...D...BH/HC
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0325 D XXX BH/HC
Consult factory upon request
0425 D XXX BH/HC
All Element K Factors in psi / gpm.
Installation
The MFX Set Manifold Cartridge Filter is installed into a threaded
cavity that is machined in the manifold (manifold not included - see cavity
drawing). A bushing is provided for proper element installation. The
bushing holds the element in place during filtration operation, and
Features facilitates easy removal for element change out.
• Integrated retrofit (quality) protection More than one SET may be installed in the manifold if required for
• High level of operational safety - Bowl seal and bypass valve are capacity. A differential pressure clogging indicator, to warn of high
integrated in the filter element and therefore replaced at every upstream pressure (element clogged), can be attached to the manifold
element change as well (cavity drawings for that upon request). For additional information,
• “Missing Element Protection” - cannot operate without element contact HYDAC.
installed.
• Non-welded housing design reduces stress concentrations and Technical Specifications
• prevents fatigue failure.
Mounting Method Threaded
• Aluminum alloy is water tolerant - anodization is not required for
water based fluids (HWBF). Flow Direction
Element Out-to-in
• Screw-in bowl requires minimal clearance to remove the element
for replacement, and contaminated fluid cannot be washed Construction Materials
downstream when element is serviced. Bowl Extruded Aluminum
• HYDAC differential Pressure Indicators (optional) have no external Flow Capacity
dynamic seal. This results in a high system reliability due to
100 26 gpm (100 lpm)
magnetic actuation, thus eliminating a potential leak point.
200 35 gpm (130 lpm)
• For special finishes and coatings – consult HYDAC for minimum
quantities, availability and pricing. Housing Pressure Rating
Max. Allowable Working
Pressure 725 psi (50 bar)
Applications Fatigue Pressure 725 psi (50 bar) @ 1 million cycles
Burst Pressure 2600 psi (183 bar)
Element Collapse Pressure Rating
BN4HC 290 psid (20 bar)
ECON2, MM 145 psid (10 bar)
Fluid Temperature Range -22°F to 212°F (-30°C to 100°C)
Agricultural Automotive Construction Commercial Consult HYDAC for applications below -22˚F (-30˚C)
Municipal
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, and high water
based fluids compatible with Nitrile Rubber (NBR) seals
∆P Indicator Trip Pressure (optional)
∆P = 36.25 psid (2.5 bar) -10% (standard).
∆P = 14.5 psid (1 bar) -10% (optional)
Railways
Bypass Valve Cracking Pressure
B1.7 = Cracking pressure (bypass valve) 25 psi (1.7) bar
B3.5 = Standard, cracking pressure bypass valve 50 psi (3.5 bar)
KB = Non-bypass option
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
2 1
INLET
24 HEX
OUTLET
83.6
60
Clearance required
for element removal
h1
Size h1
Unspecified Tolerances
From 0.5 6 30 120
MFX 100 SET 154.5 To 6 30 120 400
±0.1 ±0.2 ±0.3 ±0.5
MFX 200 SET 242.5
0.1 A 0.1 A
+0.3
90.3 0
0.05
R2±1 0.1 A
0
24-2 38
80
M90x2-6H
+0.1
87 0
Ra 1.6
A
0.1 A
+0.3
Ra 1.6
2.5 0
30°
15°
0
35-2
R1
R1
R3 R3
+0.2 +0.5
4.5 0 7.5 0
Detail Z
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
(From Tables Below) 141 SUS 0.86
ECOmicron …MX…ECON2
Size 3 μm 5 μm 10 μm 20 μm
0100 MX XXX ECON2 0.713 0.549 0.357 0.263
0200 MX XXX ECON2 0.439 0.324 0.209 0.154
Mobilemicron …MX…MM
Size 8 μm 10 μm 15 μm
0100 MX XXX MM 0.148 0.148 0.121
0200 MX XXX MM 0.088 0.088 0.071
All Element K Factors in psi / gpm.
Installation
The DF Set Manifold Cartridge Filter is installed into a threaded cavity
that is machined in the manifold (manifold not included - see cavity
Manifold cavity is only for drawing). A bushing is provided for proper element installation, as
representation and not well as a bowl with o-ring seal and back-up ring. An element can be
HYDAC’s scope of supply provided as a option. The bushing holds the element in place during
filtration operation, and facilitates easy removal for element change
out.
More than one SET may be installed in the manifold if required for
capacity. A differential pressure clogging indicator, to warn of high
upstream pressure (element clogged), can be attached to the manifold
as well (cavity drawings for that upon request). For additional information,
contact HYDAC.
Features
• N on-welded housing design reduces stress concentrations and Technical Specifications
prevents fatigue failure. Mounting Method Threaded bowl
• O -ring seals are used to provide positive, reliable sealing. Choice Flow Direction
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene Element Out-to-in
propylene rubber) provides compatibility with petroleum oils,
Construction Materials
synthetic fluids, water-glycols, oil/water emulsions, and high
Bowl (30-660) Steel
water based fluids.
Housing/Bowl (660-1320 - 2.0) Steel
• Screw-in bowl requires minimal clearance to remove the element
for replacement, and contaminated fluid cannot be washed Flow Capacity
downstream when element is serviced. 30 8 gpm (30 lpm)
• HYDAC differential Pressure Indicators (optional) have no external 60 16 gpm (60 lpm)
dynamic seal. This results in a high system reliability due to 110 29 gpm (110 lpm)
magnetic actuation, thus eliminating a potential leak point. 160 42 gpm (160 lpm)
240 63 gpm (240 lpm)
• For special finishes and coatings – consult HYDAC for minimum
280 74 gpm (280 lpm)
quantities, availability and pricing.
330 87 gpm (330 lpm)
660 174 gpm (660 lpm)
Applications 1320 200 gpm (757 lpm)
Housing Pressure Rating
Max. Allowable Working
Pressure 6090 psi (420 bar)
Fatigue Pressure 6090 psi (420 bar) @ 1 million cycles
Burst Pressure 30 15950 psi (1100 bar)
60/110 17400 psi (1200 bar)
Agricultural Automotive Construction Gearboxes 160/240/280 17110 psi (1180 bar)
330/660/1320 15080 psi (1040 bar)
Element Collapse Pressure Rating (optional)
BH4HC, V 3045 psid (210 bar)
ON, W/HC 290 psid (20 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)
Industrial Offshore Commercial Power Consult HYDAC for applications operating below 14ºF (-10ºC)
Municipal Generation Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure (optional)
∆P = 29 psid (2 bar) -10% (optional)
Pulp & Paper Railways Shipbuilding Steel / Heavy
∆P = 72 psid (5 bar) -10% (standard)
Industry ∆P = 116 psid (8 bar) -10% (optional non bypass)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
INLET
h2 min
Clearance required
for element removal
h1 - SO184 -
h6
1.2 1.2
Ra 1.6
20° 20°
1 .6 Ra
Ra 1. 6
d6 d5 r6
R0.3 R0.3
5 R0.3
R0.3
Version with -SO184 Bushing Detail
Item 4
h1
Size d1 d2 d3 d4 d5 d6 d7 d8 d9 h1 h2 h3 h4 h5 h6 h7 h8 h9 h10 HEX
-SO184
030 52 52 M55x1.5 11.9 11.9 8 42 56 55.2 76 81 75 36 34 26 18 6 4 5 1.8 24
060 68 65 M68x2 21.8 21.8 17 52 69 68.3 72.5 77.5 85 45 43 34.5 21 6 6.5 5 2.5 27
110 68 65 M68x2 21.8 21.8 17 52 69 68.3 140 145 85 45 43 34.5 21 6 6.5 5 2.5 27
140 68 65 M68x2 21.8 21.8 17 52 69 68.3 183.5 188.5 85 45 43 34.5 21 6 6.5 5 2.5 27
160 95 88 M95x2 33.8 33.8 26 75 96 95.3 106 110 105 56 54 44 25 8 6.5 7 2.5 32
240 95 88 M95x2 33.8 33.8 26 75 96 95.3 166 169.5 105 56 54 44 25 8 6.5 7 2.5 32
280 95 88 M95x2 33.8 33.8 26 75 96 95.3 348 352 105 56 54 44 25 8 6.5 7 2.5 32
330 130 125 M130x2 47.8 47.8 36 102 131 130.3 156 - 115 66 64 52.6 26 10 5 9 4 36
500 130 125 M130x2 47.8 47.8 36 102 131 130.3 249 - 115 66 64 52.6 26 10 5 9 4 36
660 130 125 M130x2 47.8 47.8 36 102 131 130.3 326.5 - 115 66 64 52.6 26 10 5 9 4 36
Unspecified Tolerances
From 0.5 3 6 30 120
To 3 6 30 120 400
±0.1 ±0.1 ±0.2 ±0.3 ±0.5
h7 h3
h4
h9 h5
20°
1 .6
Ra
H7
d4 d3
Ra 1.6
H8
d2
1.2 Ra 1.6
R1 X
h5
h5 +0.3 +0.3
d9 0 d9 0
Ra Ra
1.6 R0.3 1.6
R0.3 3.2
3.2 Ra
Ra
30° 30° 30°
30° Ra 3.2
Ra 3.2
45°
.5
12
Ra
Ra 12.5
0.5x45°
0 +1
h8-1 d8 0
DETAIL Y
h2 min
Clearance required
for element removal
h1
3 9 7 2 3 8
6 1
INLET
5
4
152
OUTLET
36
HEX
2
46
1.2 20
Ra 1.6
Size h1 h2
Unspecified Tolerances
From 0.5 3 6 30 120 400
660 2.X 319 350 To 3 6 30 120 400 1000
±0.1 ±0.1 ±0.2 ±0.3 ±0.5 ±0.8
990 2.X 477 500
h7 h3
h4
h9 h5
20°
1 .6
Ra
H7
d4 d3
Ra 1.6
H8
d2
1.2 Ra 1.6
R1 X
h5
h5 +0.3 +0.3
d9 0 d9 0
Ra Ra
1.6 R0.3 1.6
R0.3 3.2
3.2 Ra
Ra
30° 30° 30°
30° Ra 3.2
Ra 3.2
45°
.5
12
Ra
Ra 12.5
0.5x45°
0 +1
h8-1 d8 0
DETAIL Y
6 1 5
INLET
d1
OUTLET
HEX
R0.3 R0.3
R0.3 R0.3
BUSHING DETAIL
ITEM 4
140 130 125 M130x2 47.8 47.8 36 102 131 130.3 156 115 66 64 52.6 26 10 5 9 4 36
160 130 125 M130x2 47.8 47.8 36 102 131 130.3 249 115 66 64 52.6 26 10 5 9 4 36
240 130 125 M130x2 47.8 47.8 36 102 131 130.3 326.5 115 66 64 52.6 26 10 5 9 4 36
Unspecified Tolerances
From 0.5 3 6 30 120
To 3 6 30 120 400
±0.1 ±0.1 ±0.2 ±0.3 ±0.5
h7 h3
h4
h9 h5
20°
1 .6
Ra
H7
d4 d3
Ra 1.6
H8
d2
1.2 Ra 1.6
R1 X
h5 h5
+0.3 +0.3
d9 0 d9 0
Ra Ra
1.6 R0.3 1.6
R0.3 3.2
3.2 Ra
Ra
30° 30° 30°
30° Ra 3.2
Ra 3.2
45°
.5
12
Ra
Ra 12.5
0.5x45°
0 +1
h8-1 d8 0
DETAIL Y
Wire Mesh …D…W/HC Elements Metal Fiber …D…V Elements (High Collapse)
Size 25, 50, 100, 200 µm Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX W/HC 0.166 0030 D XXX V 1.011 0.740 0.411 0.200
0060 D XXX W/HC 0.042 0060 D XXX V 0.877 0.511 0.296 0.183
0110 D XXX W/HC 0.023 0110 D XXX V 0.452 0.304 0.182 0.118
0160 D XXX W/HC 0.016 0160 D XXX V 0.251 0.177 0.123 0.079
0240 D XXX W/HC 0.010 0240 D XXX V 0.169 0.137 0.093 0.062
0280 D XXX W/HC 0.005 0280 D XXX V 0.126 0.093 0.064 0.041
0330 D XXX W/HC 0.008 0330 D XXX V 0.121 0.097 0.065 0.043
0660 D XXX W/HC 0.004 0660 D XXX V 0.063 0.050 0.034 0.021
1320 D XXX W/HC 0.002 1320 D XXX V 0.032 0.026 0.018 0.012
All Element K Factors in psi / gpm.
Manifold cavity
is only for
representation
and not HYDAC’s
scope of supply
Installation
The MFM Set Manifold Cartridge Filter is installed into a threaded
cavity that is machined in the manifold (manifold not included - see cavity
Features drawing). A bushing is provided for proper element installation, as
well as a bowl with o-ring seal and back-up ring. An element can be
• N on-welded housing design reduces stress concentrations and
provided as a option. The bushing holds the element in place during
prevents fatigue failure.
filtration operation, and facilitates easy removal for element change
• O -ring seals are used to provide positive, reliable sealing. Choice out.
of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene
propylene rubber) provides compatibility with petroleum oils, More than one SET may be installed in the manifold if required for
synthetic fluids, water-glycols, oil/water emulsions, and high capacity. A differential pressure clogging indicator, to warn of high
water based fluids. upstream pressure (element clogged), can be attached to the manifold
• Screw-in bowl requires minimal clearance to remove the element as well (cavity drawings for that upon request). For additional information,
for replacement, and contaminated fluid cannot be washed contact HYDAC.
downstream when element is serviced.
• HYDAC differential Pressure Indicators (optional) have no external Technical Specifications
dynamic seal. This results in a high system reliability due to
magnetic actuation, thus eliminating a potential leak point. Mounting Method Threaded bowl
• For special finishes and coatings – consult HYDAC for minimum Flow Direction
quantities, availability and pricing. Element Out-to-in
Construction Materials
Bowl Steel
Flow Capacity
Applications 35 10 gpm (35 lpm)
55 18 gpm (68 lpm)
75 20 gpm (76 lpm)
95 25 gpm (95 lpm)
Housing Pressure Rating
Max. Allowable Working
Pressure 4060 psi (280 bar)
Agricultural Automotive Construction Gearboxes Fatigue Pressure 4060 psi (280 bar) @ 1 million cycles
4641 psi (320 bar) @ 100,000 cycles
Burst Pressure 13,920 psi (960 bar)
Element Collapse Pressure Rating (optional)
ON 290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications operating below 14ºF (-10ºC)
Industrial Commercial
Municipal Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Indicator Trip Pressure (optional)
∆P = 72 psid (5 bar) -10%
∆P = 100 psid (7 bar) +10% (standard)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
INLET
OUTLET
24 HEX
4 1 6
21
1.2 1.2
20° 20°
1 .6
Ra Ra
1. 6
Bushing Detail
Item 4
Size h1
MFM 35 SET ~ 70
Size 35 55 75 95
Weight (lbs.) 3 4.5 5.7 6.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
0.05 A
Depth of fit
1.2
Z
+0.3 Ra 1.6
76.3
0
20°
H8
H7
25.3 20 M76x2
73
1 .6
Ra 1.6 Ra
R2
A
1.5x45°
17
24
35
DEPTH OF FIT
37
43
+0.3
7 0
R1.6
Ra 3.2
30°
30°
Ra
1.6 3.2
Ra
R1.6
R0.3 - R1.6
DETAIL Z
74 min
Clearance required
2 3 for element removal
h1
INLET
OUTLET
24 HEX
4 6 1
Size h1
MFM 35 QP SET ~ 70
Size 35 55 75 95
Weight (lbs.) 3.2 4.7 5.9 6.9
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Ra 1.6
+0.3
76.3 20 M26x1.5 LH M76x2
0
H8
73
R2 1.5x45° A
17
24
35
Extent
of finish
37
45
+0.3
7 0
R1.6
Ra 3.2
30°
30°
Ra
1.6 3.2
Ra R1.6
R0.3 - R1.6
Detail C
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Installation
RFM...SET: Inside Tank Filters are installed into a separate chamber
(see tank cutaway) built into the reservoir tank via the filter ring and
four bolts. More than one filter may be installed in the chamber if
required for capacity. This procedure will require a hole to be cut
into the top of the reservoir tank and an access cover fastened to
the tank for each filter installed. The inlet piping for return should
be connected through the tank wall into the separate chamber. A
clip installed on the filter ring holds the element in place during
filtration operations, and facilitates easy removal for element change
RFM...S RFM...Set out. A static pressure clogging indicator, to warn of high upstream
pressure (element clogged), can be attached to the access cover. For
additional information, contact HYDAC.
RFM...S: Inside Tank Filters are installed to the top of the tank by
welding the inner chamber to the tank cover (see tank cutaway).
This procedure will require a hole to be cut into the top of the
Typical Installation of Both Models reservoir tank and an access cover fastened to the tank. A smaller
Tank Cutaway hole must be cut somewhere in the tank for the return line piping
to pass through. The hole located in the side of the inner chamber
must be directed towards the return line piping. The inlet piping for
return should then be welded through the tank wall and to the inner
Features chamber. The spring located between the element and the access
• U nique design allows filter to be installed completely inside of cover provides force to hold element in place during filter operation.
the reservoir tank. This saves space, protects the filter, reduces A static pressure indicator to warn of high upstream pressure,
leak points and reduces overall installation cost. and if element is clogged can be attached to the access cover.
• Lightweight unit requiring no filter head reduces pressure drop Multiple filters can be installed in the tank. For additional installation
while decreasing cost. information, contact HYDAC.
• Excellent option for low overhead clearance applications.
• Allows pre-filtration of new make-up oil assuring cleanliness of Technical Specifications
system.
• Contamination Basket prevents filtered contamination from Mounting Method See Installation at left
re-entering the tank during element changeout on 330 & 500 size Port Connection Outlet
models. 75/165 1.26” Smooth Port
• Simplifies element changeout procedure in the field. 330/500 2” NPT
• RFM Set configuration (tank plenum) allows for multiple returns to Flow Direction Inlet: Side Outlet: Bottom
enter plenum without manifolding.
Note: This filter is configured with an …..R…. type (return/low pressure)
Construction Materials
element, so if the filter requires a bypass, the bypass is located in the Chamber Steel (75/165/185)
closed end cap of the cartridge element. Bowl Plastic
Ring Aluminum (330/500)
Flow Capacity
Applications 75 RFM-S 20 gpm (75 lpm)
165 RFM-S 43 gpm (165 lpm)
330 RFM-Set 87 gpm (330 lpm)
500 RFM-Set 132 gpm (500 lpm)
Housing Pressure Rating
Max. Allowable Working Pressure: 145 psi (10 bar)
Agricultural Automotive Construction Fatigue Pressure 145 psi (10 bar)
Burst Pressure > 580 psi (40 bar)
Element Collapse Pressure Rating
Hydraulic Symbol A
ON, W/HC, MM, 290 psid (20 bar)
BN4AM, ECON2, AM, P/HC, 145 psid (10 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol,
oil/water emulsion, and high water based fluids when the
appropriate seals are selected.
Bypass Valve Cracking Pressure
∆P = 43 psid (3 bar) +10%
B ∆P = 87 psid (6 bar) +10%
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
RFM 75/165
4.04
102.5 1.57
Reservoir cutout 40
1.3
33 3.96
INLET 100.5
pipe
connection
RFM 75 Plenum
chamber
[9.88]
251
RFM165
[13.19]
335
1.26
OUTLET 2.8
32
71
1.5 Bottom of bowl
38
Size 75 165
Weight (lbs.) 2.1 2.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
3.74 3.43
95 87
6.54
166
Bolt circle
6.14
156
7.64
194
0.47
12
4 Places
Equally spaced
8.66
220
7.2 Min lid opening
183 min.
Element
hold down clamp
5.04
128
Tank Plenum
floor opening
[6.89]
RFM 330: 175
10.08
RFM 500: 256
2.68
68 2" NPT
OUTLET
4.61
117
Bottom of bowl
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
Assembly = ∆P Element = Elements (K)
∆P Flow Factor x Flow Rate (gpm) x
(From Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0075 R XXX ON 1.405 1.065 0.735 0.401 0.263 0.241
0165 R XXX ON 0.774 0.518 0.404 0.221 0.123 0.133
0330 R XXX ON 0.444 0.204 0.15 0.081 0.07 0.056
0500 R XXX ON 0.289 0.143 0.104 0.06 0.046 0.038
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0165 R XXX ECON2 0.615 0.428 0.247 0.132
0330 R XXX ECON2 0.230 0.148 0.093 0.066
0500 R XXX ECON2 0.165 0.104 0.071 0.044
Mobilemicron …R…MM
Size 8 μm 10 μm 15 μm
0075 R XXX MM 0.265 0.265 0.166
0165 R XXX MM 0.146 0.146 0.091
0330 R XXX MM 0.078 0.078 0.049
0500 R XXX MM 0.052 0.052 0.032
All Element K Factors in psi / gpm.
T T T
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
1.X
Clogging indicator
location
(right front)
Uses indicator model (VMF...)
with adapter (P/N: 02702449)
[0.2]
0.43
11
1 4 Places
25.4 (Uses M8 bolts)
Hex
0.84
21.2
4.31 4.53 3.11
109.4 115 79
Bolt circle Tank opening
Mounting pattern
4.25
108
[9.65]
3.36 245
Clearance
85.4 required for
0.59
15 element removal
Clogging indicator
port (static)
sae-4
2.76
70
11.49 3.11
291.7 79
Tank Opening
8.73
221.7
1.5 OUTLET
38
2.83
72
Housing bottom
Size 165
Weight (lbs.) 2.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print
3.0 0.20
2.5
0.15
P in bar
P in psi
2.0
1.5 0.10
1.0
0.05
0.5
0.0 0.0
0 5 10 15 20 25 30
Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0165 R XXX ON 0.774 0.518 0.404 0.221 0.123 0.133
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0165 R XXX ECON2 0.615 0.428 0.247 0.132
Replacement Element
UMC - 0010 - 117-X509-S - N - RT / __
Element Media
ULP, UMC, WPI
Filtration Rating (micron)
10, 25 = ULP
10, 20 = UMC
100 = WPI
Size
117-X509-S = RKT0170 element code
117-X512-S = RKT0230 element code
117-X516-S = RKT0300 element code
120-XZ11-Q = RKT0310 element code
117-X520-S = RKT0400 element code
120-XZ14-Q = RKT0410 element code
120-XZ18-Q = RKT0500 element code
152-X218-S = RKT0600 element code
152-X225-S = RKT0800 element code
152-X231-S = RKT1200 element code
Seals
N = Nitrile rubber (NBR)
V = Fluorocarob elastomer (FKM)
Packaging
Supplementary details
d1
h4
Clearance
h4 FILTER WITHOUT SHROUD required for FILTER WITH SHROUD
Clearance element removal
required for
element removal
h1
h1
h2
h2
→
→ h3 IN h
h3 h
IN D3
D2 D2
Flange Diameter Flange
Diameter
H2 H2
H4 Min.
→
Oil Level
OUT
H4 Min.
Oil Level
→
H1 Min. TANK
TANK H1 Min. OUT
D1
h1 h1
h2 h2
→ IN
h3 IN
h h3 → h
D3
D3
D2 D2
Flange Diameter Flange
Diameter
H4 Min.
Oil Level
H2
H4 Min.
Oil Level
H2
→
H3 OUT
H3 →
OUT
4x90°
d3
h3
←
IN
h h3
← h
IN
D2 D2
Flange Diameter Flange Diameter
H2
H2
H4 Min.
Oil Level
→
OUT
H4 Min.
Oil Level
H1 Min.
Tank
D1 H1 Min. D1 Tank
↓
OUT
h3 ←
IN
h h3 ←
IN
h
D2 D2
Flange Diameter Flange Diameter
H2
H2
H4 Min.
H4 Min.
Oil Level
→
OUT
Oil Level
H3
→
OUT
H3
D1 H1 Min. D1 Tank
H1 Min.
Tank
+1
85 0
3 x Clamp
8
3x120
d1
h3 In
D3
← h3
D3
←
IN IN
D2
Flange Diameter D2
Flange Diameter
H2 H2
H4 Min.
Oil level
H4 Min. H3
→
OUT
Oil level
H1 Min.
↓OUT H1 Min. D1
Tank Tank
ØD1
h1
h2
D2
Flange Diameter
H4 Min.
Oil level
H2
H3
→
OUT
H1 Min.
D1 Tank
Shroud Wt
Type H1 H2 H3 H4 h1 h2 h3 h4 ØD1 ØD2 ØD3 Ød1
Version (lbs)
[0.98] [2.95]
With shroud -
25 75
0.5 A 5
+0.3
5 0
Flange Welded Leaktight
1.
6
15° 150
D1±0.2
137
45° 30°
+0.3
+0.1 D2 - 0.1 126±0.5
156.2 0
+0.2
121.4 0 116.5±0.1
+0.2
152.2 0
A
Filter Installation:
4x M10 W Tank Flange Not Supplied
2
Cover Flange
Not Supplied 10 Min. 15
92
Shroud Design B - L - R
0.5 W
0.2 Flange Welded Leaktight
0.5 A
A
1.5
+0.2
152.2 0 +0.25
D2 0 170
D1±0.2 160
45°
1.6
5±0.5
1.5x30
1.
Shroud Design X 6
0.5 W 45°
0.2
1.6
Flange welded leaktight
0.5 a
Flange welded leaktight DETAIL X
SCALE 1 : 2
Filter installation
W
Tank flange no supplied.
4xM12 3
18 Min. 18
Cover flange
118
not supplied.
Shroud Design B - L - R
Flange welded leaktight
1.6
0.5 a 0.5 W 3
0.2
W
4x90° Flange welded leaktight
0.5 a 3
15°
1.6
a
d3±0.2
225
Filter installation
Tank flange no supplied.
4xM12
9
Cover flange
not supplied. 12
118
3x120° a
4x90° 212±0.2
W
1.6
d1±0.2
4xM12
R80 3
17
12 Min.
+0.7
h3 - 1.3
Sizing Information
Assembly Curve:
Pressure loss through housing is as follows:
Adjustments must be made for viscosity & specific gravity of the fluid to be used!
Actual Specific Gravity
Assembly ∆P = Assembly Curve ∆P x
0.86
Note: All curves represent 30 cSt viscosity.
6 0.4 6 0.4
ΔP in psid
ΔP in psid
ΔP in bar
ΔP in bar
0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q (gpm) Q (gpm)
ΔP in psid
20µm UMC
ΔP in bar
ΔP in bar
5 6 20µm UMC 0.4
0.3 5
4
10µm ULP 0.3
4 10µm ULP
3 0.2
3 0.2
2 25µm ULP
0.1 2 25µm ULP
1 0.1
1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q (gpm) Q (gpm)
ΔP in psid
6 6
ΔP in bar
ΔP in bar
10µm ULP 0.4 10µm ULP 0.4
5 5
0.3 0.3
4 4
20µm UMC 20µm UMC
3 0.2 3 0.2
2 25µm ULP 2 25µm ULP
0.1 0.1
1 1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q (gpm) Q (gpm)
ΔP in psid
6 0.3
ΔP in bar
ΔP in bar
10µm ULP 0.4 4
5 10µm ULP
0.3 3
4 0.2
20µm UMC
3 25µm ULP
0.2 2
2 25µm ULP 0.1
0.1 1
1
0 0 0 0
0 10 30 50 70 90 110 130 150 0 20 40 60 80 100 120 140 160 180 200
Q (gpm) Q (gpm)
ΔP in psid
ΔP in bar
ΔP in bar
0.3 5
4 0.3
10µm ULP 4
3 0.2 25µm ULP
3 0.2
25µm ULP
2 2
0.1
1 0.1
1
0 0 0 0
0 20 60 100 140 180 220 260 0 50 100 150 200 250 300 350
Q (gpm) Q (gpm)
TANK
Replacement Element
UMC - 0010 - 117-X509-S - N - RT / __
Element Media
ULP, UMC, WPI
Filtration Rating (micron)
10, 25 = ULP
10, 20 = UMC
100 = WPI
Size
Filter with Flange B or E
152-XD18-S = RKB0600 element code
152-XD25-S = RKB0800 element code
152-XD31-S = RKB1200 element code
Filter with Flange C or I
152-XD18-Q = RKB0600 element code
152-XD25-Q = RKB0800 element code
152-XD31-Q = RKB1200 element code
Seals
N = Nitrile rubber (NBR)
V = Fluorocarob elastomer (FKM)
Packaging
Supplementary details
D4
Fastening elements, eg.:
Hex. nut with collar
Din EN 1661-M12
Stud DIN938-M12x30-8.8
D4
D1
H2
↑ Tank
IN K
D4±0.2
D3
↑ Tank
IN K
D4±0.2
D4
D3
D2 D1
H1
H2
H3 → ↑
OUT Tank
IN K
D3 D4±0.2
H4 Min.
Oil level
↑
Tank
IN K
D4±0.2
Dimensions
RKB 0600-1200
Flange welded
30±0.1
leaktight
Flange welded
1.5 B
Welding flange leaktight 5
0.2
d1±0.2 not supplied
3xM10 2.5 A
3x120°
12°
D4±0.2
+1 0 +0.2
4x90° 90 0 200-0.5 183.1 - 0.3
189 A
+1
3.2
207 D2 0
170 Min d1±0.2
1
5 0.2
45°
D4±0.2 21±0.1 4xM12
B 3
Cover flange
3.2
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Q (l/min)
0 100 200 300 400 500 600 800
0.6
8
0.5
7
10µm UMC
6 0.4
ΔP in bar
ΔP in psi
5 20µm UMC
0.3
4
10µm ULP
3 0.2
2 25µm ULP
0.1
1
0 0
0 20 40 60 80 100 120 140 160 180 200
Q (gpm)
Q (l/min)
0 100 200 300 400 500 600 700 800 900 1000
10 0.6
0.5
8
10µm UMC
0.4
ΔP in psid
6
ΔP in bar
20µm UMC
0.3
10µm
ULP
4
0.2
25µm ULP
2 0.1
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Q (gpm)
Q (l/min)
0 200 400 600 800 1000 1200 1400
10 0.6
10µm UMC
0.5
8
20µm
UMC
0.4
ΔP in psid
6
ΔP in bar
10µm
ULP
0.3
4
25µm ULP 0.2
2
0.1
0 0
0 50 100 150 200 250 300 350 375
Q (gpm)
The filter housings are designed in accordance with international Flow Capacity
regulations. They consist of a filter cover, filter head, shroud cover, 0170 45 gpm (170 l/min)
and element location nozzle. 0230 66 gpm (250 l/min)
0300 79 gpm (300 l/min)
The element is top-removable. 0310 92 gpm (350 l/min)
Standard equipment 0400 105 gpm (400 l/min)
0410 118 gpm (450 l/min)
• Magnetic core integrated into clamp (only for RFT 0170 – 0500) 0500 145 gpm (550 l/min)
• Magnetic core integrated into cover (only for RFT 0600 – 2400) 0600 158 gpm (600 l/min)
• with protective tube 0800 211 gpm (800 l/min)
• with bypass valve 1200 317 gpm (1200 l/min)
1800 475 gpm (1800 l/min)
Filter Elements 2000 528 gpm 2000 l/min)
HYDAC filter elements are validated and their quality is constantly 2400 634 gpm (2400 l/min)
monitored according to the following standards: Housing Pressure Rating
ISO 2941, ISO 2942, ISO 2943, ISO 3724,ISO 3968, ISO 11170, ISO Max. Allowable Working
16889 Pressure* 145 psi (10 bar) MAWP
Filter elements are available with the following pressure stability Element Collapse Pressure Rating
values:
ULP, UMC, WPI 87 psid (6 bar)
Glass fiber (ULP): 87 psi (6 bar) Fluid Temp. Range -22°F to 248°F (-30°C to 120°C)
Glass fiber with pre-filter (UMC): 87 psi (6 bar)
Consult HYDAC for applications below -22˚F (-30˚C)
Wire mesh (WPI): 87 psi (6 bar)
Fluid Compatibility
Other filtration ratings on request.
Compatible with all hydrocarbon based, synthetic, water glycol,
Special Models and Accessories oil/water emulsion, and high water based fluids when the
• without magnetic core appropriate seals are selected.
• without shroud (only RFT 0170 – 500) Indicator Trip Pressure
• with shroud P = 29 psi (2.0 bar) standard
• Outlet grill in openings in shroud P = 11 psi (0.8 bar) optional - consult factory
• Seals made of FKM Bypass Valve Cracking Pressure
• Hydraulic oils H to HLPD DIN 51524
∆P = 36 psi (2.5 bar) standard)
• Lubrication oils DIN 51517, API, ACEA, DIN 51515, ISO 6743 ∆P = 11 psi (0.8 bar) optional
• Compressor oils DIN 51506
• Biodegradable operating fluids VDMA 24568 HETG, HEES, HEPG
Important Information Applications
• Filter housings must be grounded
• When using electrical clogging indicators, the electrical power
supply to the system must be switched off before removing the
clogging indicator connector
h2
h2 min min clearance
FILTER WITHOUT SHROUD Clearance
required for required for
FILTER WITH SHROUD
element removal element removal
h1
h1
h
h
h3
h3 D2 D2
Flange diameter Flange diameter
H2
H2
h4 min
Oil level →
OUT
H4 MIN
Oil level
h1 min
Tank ↓ OUT Tank
h1 MIN
D1
h2
min clearance h2
required for FILTER WITH DIFFUSER min clearance
FILTER WITH DIFFUSER element removal
(OPENING WITH GRILL) required for
element removal
h1 h1
h h
h3
D2
h3 D2
Flange diameter
Flange diameter
H4 MIN
Oil level
H2 H2
H4 MIN
Oil level
H3 →
OUT
→
H3
OUT
J2 J1
G1/8” G1/8” 2x f±0.2
4x90° h4
4x k2
4x k 2x d±0.2
SAE DN 40 (1-1/2")
E1
IN ↑ 45°
d3
Shroud Wt
Type H1 H2 H3 H4 h h1 h2 h3 h4 ØD1 ØD2 Ød3 a b c d f Øk Øk2
Version (lbs)
* Non-machined port
** Machined port
h2 min h2 min
Clearance FILTER WITH SHROUD Clearance
FILTER WITHOUT SHROUD required for required for
element removal element removal
→ h1
→
h1
IN IN
h
h
h3 h3
D2
D2 Flange Diameter
Flange Diameter
H2 H2
H4 MIN
→
Oil level
OUT
H4 MIN
Oil level
Tank
H1 min
↓
H1 MIN OUT
Tank D1
h1
→ h1 →
IN
h h IN
h3 h3
D2 D2
Flange diameter Flange Diameter
H4 MIN
H2 Oil level
H4 MIN H2
Oil level
→
H3 → H3 OUT
OUT
H1 MIN D1 Tank
H1 MIN D1 Tank
b a k 4x
Torque TANK MOUNTING
25+5 Nm J 4 x Hex head screws
(18.5 ft lbs + 4 ft lbs) G1/8” M12x30
Recommended torque 30 +5 Nm
by using the specified standard
→
E1 parts and flange made of steel
IN 45°
A
c d3
IN
→
→
IN B
A → →
4x90°
E2
d
k 4x
E1
→
E1
IN 45°
B
A
d3
→
h4
E1
E2
B
Wt
Type Design H1 H2 H3 H4 h h1 h2 h3 h4 ØD1 ØD2 Ød3 a b c d Øk
(lbs)
IN
b
E5
←
B
d3
→D
IN
4x90°
D2
a
Flange diameter
H2
E1
45°
H4 min
Oil level d
c e
→
H1 min
Tank OUT h2 min A ↑IN h2 min
Clearance
D1 Clearance required
required for element
FILTER WITH DIFFUSER
for element removal
(OPENING WITH GRILL)
FILTER WITH DIFFUSER removal
h1
h1
h3
h3
D2
Flange diameter
H4 min
Oil level
D2
Flange diameter
H2
H4 min H2
Oil level
H3
→
Out
H3 →
Out
H1 min Tank
H1 min D1 D1
Tank
h4
h7
E1
E4
h6 h7
h5
E5
J1
G1/8”
Wt
Type Design H1 H2 H3 H4 h h1 h2 h3 h4 ØD1 ØD2 Ød3 a f f2 g g2 Øk Øk2
(lbs)
With [0.39] [3.15]
- 26.5
shroud 10 80
With [5.51]
RFT diffuser [18.94] 140 [19.69] 26.9
0600 [0.2] 481 [0.39] 500
Diffuser 5 10
[11.42]
with 27.1
290
opening
With [0.39] [3.15]
- 28.2
shroud 10 80
[4.21]
With [5.51] M12
RFT [26.54] [1.63] [4.41] [27.56] [0.51] [2.01] [6.81] [6.89] [8.66] 107* [2.75] [3.06] [1.41] [1.69] [0.49] 28.7
diffuser 140 18
0800 [0.2] 674 [0.39] 41.5 112 700 13 51 173 175 220 [4.17] 69.9 77.8 35.7 42.9 12.5
deep
Diffuser 5 10 106**
[15.75]
with 28.9
400
opening
With [0.39] [3.15]
- 34.6
shroud 10 80
With [5.51]
RFT diffuser [32.6] 140 [35.43] 35.1
1200 828 [0.39] 900
Diffuser [0.2] 5 10
[21.65]
with 35.3
550
opening
* Non-machined port
** Machined port
↑IN
Recommended torque 30 +5 Nm (22 + 4 ft-lbs)
by using the specified standard
parts and flange made of steel
h1 h1
h h
h3 h3
D2 D2
Flange diameter Flange diameter
H2 H2
H4 Min.
Oil level
H4 Min. OUT
Oil level
H3
→
H1 Min. OUT
↓ Tank H1 Min.
D1 Tank
D1
h2 min
Clearance required
for element removal
h1
h
h3
D2
Flange diameter
H4 min
Oil level
H2
OUT
H3
→
H1 Min. Tank
D1
J2 4x k
G1/8” J1
b
G1/8”
d3 2x g±0.1
4X90°
a
4x k2 E1 45°
↑IN
Recommended torque 30 +5 Nm (22 + 4 ft-lbs)
by using the specified standard
parts and flange made of steel
h1 h1
h h
h3 h3 Wt
Type Design H1 H2 H3 H4 h h1 h2 h3 ØD1 ØD2 Ød3 a b c f g Øk Øk2
(lbs)
D2 D2
With [1.38] [5.12]
- Flange diameter Flange diameter 64.6
shroud 35 130
With [7.09]
RFT diffuser [36.22] 180 [35.43] 66.8
1800 [0.59] 920 [0.39] 900
Diffuser 15
[16.14] 10
with 67.2
410
opening SAE
4" SAE
With [1.38] [5.12]
shroud 35
-
130 [5.13] 4" 76.5
[5.98] [5.98] [5.98] 130.2 [3.06] M
RFT With [47.24] [8.07] [45.28] 152* 152* 152* 77.8 16x32
[2.87] [6.89] [0.75] [9.35] [9.43] [11.61] [0.53] 78.7
2000 diffuser
H2[0.59] 1200 205
[0.39] 73 175 1150 19 237.5 H2 239.5 295 SAE deep 13.5
Diffuser 15 [5.91] [5.91] [5.91] 3" SAE
[21.65] 10 150** 150** 150** [4.19] 3"
with 79.1
550
opening 106.4 [2.44]
61.9
With [1.38] [5.12]
- 78.9
shroud 35 130
H1 Min. OUT
↓ Tank H1 Min.
D1 Tank
D1
10 MIN
1.6
RFT 0170, 0230, 0300, 0400
4xM8
10 MIN
1.6
165
4xM8
165
d3±0.1 D2±1
2
d3±0.1 D2±1
30°
0.2
30°
4x90° 45°
0.2
Tank flange Flange welded
not supplied leaktight
4x90° 45°
Tank flange Flange welded
18 MIN
RFT 0310, 0410, 0500 not supplied leaktight
1.6
Dimensions 4xM8
18 MIN
RFT 0310, 0410, 0500
RFT 0310, 0410, 0500
1.6
200
4xM8
200
D2±1
d3
D2±1
d3
0.2
4x90°
45°
0.2
Tank flange Flange welded
4x90° not supplied leaktight
45°
3.2
20
18 MIN
4xM12
+0.05
220 1.1 - 0.15
30°
+0.2
2 0
0
d3±0.1 D2-0.1
0.2
4x90°
45°
Tank flange Flange welded
not supplied leaktight
Dimensions
RFT 1800, 2000, 2400
5
1.6
4xM12
290
0
240.4 - 0.2
+1
D2 0
0.2
4x90° d3±0.1
45° Tank flange not
supplied
Adjustments must be made for viscosity & specific gravity of the fluid to be used!
Q (l/min) Q (l/min)
0 25 50 75 100 125 150 175 200 225 250 0 50 100 150 200 250 300
0.6 0.6
8 8
10µm UMC 0.5 0.5
7 7 10µm UMC
6 0.4 6 0.4
20µm UMC
ΔP in psid
ΔP in psid
20µm UMC
ΔP in bar
ΔP in bar
5 5
0.3 0.3
4 4
10µm ULP 10µm ULP
3 0.2 3 0.2
2 2
25µm ULP 0.1 25µm ULP 0.1
1 1
0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q (gpm) Q (gpm)
Q (l/min) Q (l/min)
0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400 450 500
0.6 0.6
8 8
10µm UMC
10µm UMC 0.5 0.5
7 7
20µm UMC
6 6 0.4
20µm UMC 0.4
ΔP in psid
ΔP in psid
ΔP in bar
ΔP in bar
5 5
0.3 10µm ULP 0.3
4 10µm ULP 4
3 0.2 3 0.2
25µm ULP
2 25µm ULP 2
0.1 0.1
1 1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q (gpm) Q (gpm)
Q (l/min) Q (l/min)
0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400 450 500
10 0.7 10 0.7
10µm UMC 10µm UMC
9 9
0.6 0.6
8 8
7 0.5 7 0.5
ΔP in psid
ΔP in bar
ΔP in bar
0.4 0.4
5 5
0.3 0.3
4 4
20µm UMC
20µm UMC
3 0.2 3 0.2
2 25µm ULP 2 25µm ULP
0.1 0.1
1 1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q (gpm) Q (gpm)
6 10µm ULP
ΔP in psid
ΔP in psid
0.3
ΔP in bar
ΔP in bar
0.4 4 10µm ULP
5
0.3 3
4 20µm UMC 0.2
3 25µm ULP
0.2 2
2 25µm ULP 0.1
0.1 1
1
0 0 0 0
0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200
Q (gpm) Q (gpm)
ΔP in bar
7 0.5
20µm UMC
5 10µm ULP
ΔP in psid
ΔP in psid
6
ΔP in bar
0.3 0.4
4 5
10µm ULP
0.3
3 4
0.2 25µm ULP
25µm ULP 3 0.2
2
0.1 2
1 0.1
1
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 50 100 150 200 250 300 350
Q (gpm) Q (gpm)
ΔP in psid
ΔP in bar
0.4 0.3
10µm ULP 4 25µm ULP
0.3
ΔP in bar
4 3 0.2
25µm ULP
0.2
2
2 0.1
0.1 1
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 0 100 200 300 400 500 600
Q (gpm) Q (gpm)
ΔP in bar
5 0.4
3
0.2
2
0.1
1
0 0
0 100 200 300 400 500 600 700
Q (gpm)
Recommended torque
4x k J1 connection for differential
25 +5 Nm by using the specified
standard parts and flange made of steel pressure indicator
Housing closure V
Housing closure H
h2 min
Clearance required h2 min
for element removal Clearance required
↓ A for element removal
←
B h1 h1
H4
H5
H1
H1
→
→
OUT
OUT
H2 H2 H3 Min.
H3 Min.
Oil level Oil level
←
IN
↑IN
D1 D1
Connection Weight
Type Design H1 H2 H3 H4 H5 h1 h2 h3 ØD1 Ød1 Ød2 Øk
position (lbs)
Diffuser with [12.7] [8.68] [7.32] [11.69]
H - 7.3
RFB opening 322.5 220.5 186 297 [11.81]
0170 Diffuser with [11.99] [7.97] [6.61] [10.61] 300
V - 7.1
opening 304.5 202.5 168 269.5 [2.42] [0.69] [5.28] [7.09] [7.87] [0.41]
Diffuser with [18.6] [11.67] [10.31] [17.6] 61.5 17.5 134 180 200 10.5
H - 8.6
RFB opening 472.5 296.5 262 447 [17.72]
0300 Diffuser with [17.89] [10.96] [9.61] [16.52] 450
V - 8.8
opening 454.5 278.5 244 419.5
h3
4x k1
← h1 h1
B
H1
H5 H1
H5
H2 →
H2 OUT
H3 min
→
OUT
Oil level
H3 min
Oil level
←
IN
↑ IN
D1
D1
Connection Weight
Type Design H1 H2 H3 H4 H5 h1 h2 h3 ØD1 Ød1 Ød2 Øk1
position (lbs)
Diffuser with [18.37] [12.09] [9.21] [16.85]
H – 9.9
RFB opening 466.5 307 234 428 [16.93]
0400 Diffuser with [16.63] [10.34] [7.17] [15.5] 430
V - 9.5
opening 422.4 262.6 182 393.8 [2.42] [0.69] [6.06] [7.31] [8.07] [0.41]
Diffuser with [24.16] [15.09] [12.2] [22.65] 61.5 17.5 154 185.7 205 10.5
H – 12.1
RFB opening 613.7 383.2 310 575.2 [22.83]
0600 Diffuser with [22.11] [13.04] [10.16] [21.3] 580
V - 11.7
opening 561.6 331.1 258 541
Dimensions
RFB 0170-0300
200 MIN Tank flange not supplied
Ra3.2
D
140±1 180
C D 22.5°
0.2 W A
0.2
90°
4 x M10
0.2 A 15
4x 90° (=360 ) MIN
SECTION D-D
W
2 A
2 C
2 x 30 H5
Tube not
40 max supplied
Installation depth
3.2
Ra
2 x 30 30 min
Installation depth
Ra
35±0.2
3.2
40 MIN
30 MIN Ra3.2
Sealing surface Sealing
Tube not supplied
area
Ra3.2
25 min surface
Installation depth
area
30 max
Installation depth
35±0.2 2 W 65
Ra3.2
D
185.7
155.5±0.1
C D 22.5°
0.2 W A
0.2 A 0.2
90°
W 15
MIN
4x 90° (=360 )
SECTION D-D
2 A
2 C
2 x 45
H5
Tube not
40 max supplied
Installation depth
2
3.
Ra
30 min
2 x 30 Installation depth
57.7±0.2
Ra
3.2
40 MIN
Ra3.2
26 MIN Ra3.2
Sealing surface Tube not
area supplied 20 min Sealing
Installation depth surface
57.7±0.2 2 W 26 max area
Installation depth
65
Q (l/min) Q (l/min)
0 50 100 150 200 250 0 50 100 150 200 250 300 350
400
0.6 0.6
8 8 10µm UMC
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
5 5
0.3 10µm ULP 0.3
4 10µm ULP 4
3 0.2 3 0.2
25µm ULP
2 2
25µm ULP 0.1 0.1
1 1
0 0 0 0
0 10 20 30 40 50 60 0 20 40 60 80 100
Q (gpm) Q (gpm)
Q (l/min) Q (l/min)
0 100 200 300 400 500 600 0 100 200 300 400 500 600 700 800 900
0.6 10 0.7
8 10µm UMC 10µm UMC
0.5 0.6
7 20µm UMC
20µm UMC 8
6 0.5
0.4
ΔP in psid
ΔP in psid
6
ΔP in bar
ΔP in bar
5 10µm ULP 0.4
10µm ULP
0.3
4 25µm ULP 0.3
4
3 25µm ULP 0.2
0.2
2
0.1 2
1 0.1
0 0 0 0
0 10 30 50 70 90 110 130 150 0 10 30 50 70 90 110 130 150 170 190 210 230
Q (gpm) Q (gpm)
A A
FI FI
B B
20.2
513
1 5 .8 5
4 0 2 .7
6 .9 7
177
8.94
R 2 27
T r a n s f e r v a lv e
h a n d le
tu rn ra d i u s
[5 0 0 ]
19.69 P re s s u re
C l e a r a n c e fo r Lid ve n t e q u a l iz a t io n
e le m e n t re m o va l S A E - 4 p o rt line
(vent valving
o p t io n a l )
∆ P C lo g g i n g
i n d i c a to r
p o rt 8 .6 3
G 1 /2 " 219 INLET
2 " A N S I 1 5 0 lb s . R F
2 9 .3 7 Dirty side Flange
D rai n - S A E -1 2
7 4 6 .1 (drain valving 7 .4 8
optional) 190
3 2 .6 9
5 .9 1 8 3 0 .2
1 50
C l e a n s i de
dr a i n - S A E -1 2
(drain valving
o p t io n a l )
4 OUTLET 5 .1 4
1 0 1 .6 2" A N S I 15 0 lb s. R F 1 3 0 .6
F l a ng e
0 .8 8 3 0 .2
2 2 .2 767
T h ru
8 P la c e s
12
10 3 0 4 .8
254
3 2 .2
8 1 7 .8
M o u n ti n g P a tte rn
19.4
492.7
5.12
130
23.17
588.4 12.48
R317 RFLDH 1320
37.76
[37.01] [14.45]
959.2
RFLDH1320: R367 RFLDH 1323
940
Clearance for Lid vent Transfer valve
element removal SAE-4 port handle
(vent valving turn radius
optional)
8.63 Pressure
219.1 equalization
line
∆P Clogging
indicator INLET
48.75 port 4" ANSI 150 lbs. RF
1238.3 G 1/2" Flange
9.84
52.06
Dirty side 250
1322.4
Drain- SAE -12
7.87 (drain valving
200 optional)
Clean side
Drain- SAE -12 8.5
(drain valving 216
4 optional) OUTLET
101.6 4" ANSI 150 lbs. RF
Flange
0.88
34.4
22.2
873.8
Thru
8 Places
10.5 12
266.7 304.8
35.9
911.9
Mounting Pattern
22.54
572.6
21.02
533.9
4.72
120
12.48
R317 RFLDH 2500
[420] [14.45]
16.54 R360 RFLDH 2503
Clearance for Transfer valve
element removal Lid vent handle
SAE-4 port Pressure
turn radius
∆P Clogging (vent valving equalization
indicator optional) line
port
G 1/2"
INLET
3" ANSI 150 lbs. RF
26.74 Dirty side 10.75 Flange
679.2 Drain- SAE-12 273.1
(drain valving
optional) 30.05
763
6.1 9.06
154.9 230
Clean side
Drain- SAE-12
(drain valving
optional)
OUTLET 6
3" ANSI 150 lbs. RF 152.4
Flange
0.75
19.1
35.5
Thru
901.7
8 Places
13 15
330.2 381
37.5
952.5
Mounting Pattern
19.49
495
5.12
130
37.08
941.8
12.49
R317 RFLDH2520
[14.45]
R360 RFLDH2523
Transfer valve
[810] handle
31.89
Clearance required Lid vent turn radius
for element removal SAE-4 port
(vent valving Pressure
optional) equalization
line
∆P Clogging
indicator
port 10.75
G 1/2" 273.1 INLET
4" ANSI 150 lbs.
Dirty side RF
Drain- SAE -12 Flange
(drain valving 47.50
44.19 optional) 1206.5
1122.4
8.50
216
9.84
250
Clean side
Drain- SAE -12
(drain valving
optional)
33.92
0.88
861.6
22.2
Thru 10.83
8 Places 275.1
11.00 14.00
279.4 355.6
37.08
941.80
Mounting Pattern
22.48
571.1
7.48
190
[12.48]
R317
[31.89] Lid vent T.V. handle
810 SAE-4 port turning radius
Clearance required (vent valving
for element removal optional) Pressure
equalization
line
67.5
1714.5 Max
62.52
1588
14 INLET
Dirty side 6" ANSI 150 lbs. RF
Drain- SAE-12 355.6 Flange
(drain valving
optional)
12.5
53.72 317.5
1364.6 11.81
300
Clean side
Drain- SAE-12
(drain valving
optional)
9
15 OUTLET 228.6
381 6" ANSI 150 lbs. RF
Flange
46.51
0.75 1181.4
19.1
16 20
406.4 508
50.51
1283
Mounting Pattern
Size 4020
Weight (lbs.) 1500
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
40 0.4
2.5 5
30 2.0 0.3
4
20 1.5 3 0.2
10 2
10 0.1
0.5 1
0 0 0 0
0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400
Q (gpm) Q (gpm)
50 3.5 25
3.0 1.5
40 20
2.5
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
30 2.0 15 1.0
20 1.5 10
10 0.5
10 5
0.5
0 0 0 0
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700
Q (gpm) Q (gpm)
12 0.8
10
ΔP in bar
ΔP in psi
0.6
8
6 0.4
4
0.2
2
0 0
0 200 400 600 800 1000
Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
Elements = Elements (From
∆P (K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Optimicron …R…ON
Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0850 R XXX ON 0.152 0.072 0.055 0.032 0.024 0.02
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.012
1700 R XXX ON 0.074 0.035 0.029 0.015 0.014 0.01
2600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2
Size 3 μm 5 μm 10 μm 20 μm
0850 R XXX ECON2 0.082 0.055 0.038 0.022
1300 R XXX ECON2 0.044 0.033 0.022 0.016
1700 R XXX ECON2 0.038 0.027 0.016 0.011
2600 R XXX ECON2 0.022 0.016 0.011 0.005
A A
FI FI
B B
Technical Specifications
Mounting Method Floor mounted legs
(Filters must not be used as pipe support)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
M
Transfer
valve handle
turn
O
radius
Differential pressure Clearance required B
Connections for element removal
(G 1/4") C
2 Places
Vent Port
(G 1/8") INLET
2 Places
J H
E OUTLET
A
N
M16X2
I
G D
M12x1.75
3.25 F
82.6
3.94
Dirty side Clean side 0.87 100
drain port drain port 22
(G 3/4") (G 3/4") 4 Places
2 Places 2 Places
3.94
100 0.79
20
Size A B C D E F G H I J K L M N O Connection
AFLD [20.24] [4.99] [2.49] [7.87] [6.10] [9.09] [8.50] [6.10] [9.02] [6.04] [3.78] [4.25] [7.20] [3.13] [7.68] ANSI 150 lb
122/123 514 126. 8 63.4 200 155 230.8 216 155 229 153. 5 96 108 183 79.4 195 RF 1"
AFLD [23.5] [7.04] [3.91] [8.74] [8.66] [12.87] [9.57] [8.66] [10.71] [6.69] [4.79] [5.71] [8.94] [3.87] [8.07] ANSI 150 lb
232/233 597 178. 8 89.4 222 220 326.8 243 220 22 170 121. 7 145 227 98.4 205 RF 1.5"
B4
Vent Port
(G 3/4") B3
2 PL
[0.08]
2 B5
[8.94]
R227
øD2 Transfer valve
handle turn radius
Differential Pressure H6
Connections Clearance required
(G 1/4") for element removal B2
2 Pl
H2
H5
H8
M16X2
Flange holes INLET
H3
H1
OUTLET
[ø3.25]
H7 Dirty side H4
drain port ø82.6
(G 3/4") M16X2
2 PL 8 PL
[0.39]
Clean side 10
B1
drain port
(G 3/4")
2 PL
B6
[4.15]
[3.94]
105
100
[ø0.87]
ø22 THRU
[3.94] 4 Places
100
[0.77]
20 [3.54] Mounting Pattern
90
Size Flange Size B1 B2 B3 B4 B5 B6 D2 H1 H2 H3 H4 H5 H6 H7 H8
AFLD [15.75] [9.13] [6.69] [5.16] [1.38] [5.91] [6.65] [22.56] [20.59] [19.65] [9.25] [6.69] [8.07] [11.38] [5.91]
332/333 400 232 170 131 35 150 169 573 523 499 235 170 205 289 150
AFLD [15.75] [9.13] [6.69] [5.16] [1.38] [5.91] [6.65] [25.71] [23.78] [22.83] [9.25] [6.69] [11.81] [11.38] [9.09]
2” 150 lb
502/503 400 232 170 131 35 150 169 653 604 580 235 170 300 289 231
AFLD [15.75] [9.13] [6.69] [5.16] [1.38] [5.91] [6.65] [22.56] [26.69] [25.71] [9.25] [6.69] [14.57] [12.4] [12.4]
542/543 400 232 170 131 35 150 169 573 678 653 235 170 370 315 315
7.87
ALFD 882 R200
[5.20]
AFLD 883: R132 Pressure equalization line
Equalization line
handle turn radius
9.07
230.5
17.24
6.69
R438
170
Transfer 9.88
valve 251
handle turn
radius 19.76 [20]
502 515
Clearance required
29.09 for element removal Vent Port
739 (G 3/4")
INLET
3" ANSI 150LB RF Differential
Flange 32.83 pressure ports
Use bolts 834 (G 1/4") 16.18
5/8"-11UNC 411
Heavy hex
12.99 5.00
330 127
35.31
897
Dirty side
17.32 vent plug
440 (G 3/4")
10.83 2 Places
275
Clean side
vent plug
(G 3/4")
2 Places
OUTLET
3" ANSI 150LB RF 9.09
Flange 231
Use bolt
5/8"-11UNC
Heavy hex 0.87
22
16.93
430
Mounting Pattern
90°
L2
b4
12.6 9.84 7.48
320 250 190
b3
0.08 0.87
2 L1
22
b5
View: F
90°
M16X2
INLET 3.25
82.6
h8
h7
OUTLET
b1
Vol. of
Flange M1 Pressure
Size b1 b2 b3 b4 b5 d1 h1 h2 h3 h4 h5 h6 h7 h8 L1 L2
Size [N/m] Vessel,
[liters]
AFLD 4” [6.1] [7.9]
8 x ø19 170
1402 150 lbs [33.6] [23] [8.3] 155 [18.8] [41.6] [38.3] [11] [15.2] [25.6] [8.5] [6.3] [20.9] [17.2] 200
2 x 24
AFLD 4” 854 584 210 [10.5] 478 1057 972 280 385 650 216 160 532 438 [5.2]
8 x ø23 110
1403 300 lbs 266 132
Size 1402 1403
Weight (lbs.) 639 639
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
90°
L2 7.48
190
b4
12.6 8.66
320 220
b3
0.04 L1
0.87
1 22
90° b5
View: F
h5
Clearance required Torque value for cover
for element removal plate screws M1
G 1/2"
Vent port Vent port G 3/4" and
flange connection
3/4" 300 lbs.
b2
b1
Vol. of
Flange M1 Pressure
Size b1 b2 b3 b4 b5 d1 h1 h2 h3 h4 h5 h6 h7 h8 L1 L2
Size [N/m] Vessel,
liters
AFLD [7.2] [7.9]
2702 6” [38.6] [25.7] [7.5] 184 [25.4] [38] [34] [11.8] [16.7] [19.7] [9.4] [7] [15.1] [12.5] 200
8 x ø23 110 2 x 37
AFLD 150 lbs 980 653 190 [9.8] 645 964 863 300 425 500 239 177 383 317 [5.2]
2703 249 132
Size 2702 2703
Weight (lbs.) 794 794
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
ΔP in bar
ΔP in bar
ΔP in psi
ΔP in psi
6 0.4 6 0.4
4 4
0.2 0.2
2 2
0 0 0 0
0 5 10 15 20 25 30 0 10 20 30 40 50 60 70
Q (gpm) Q (gpm)
ΔP in bar
ΔP in psi
ΔP in psi
9 0.6
3 0.2
6 0.4
2
0.1
1 3 0.2
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 25 50 75 100 125 150
Q (gpm) Q (gpm)
ΔP in bar
ΔP in psi
3 2.7
ΔP in psi
0.20 0.18
0.15
2 1.8 0.12
0.10
1 0.9 0.06
0.50
0 0 0 0
0 50 100 150 200 250 0 85 170 255 340 425
Q (gpm) Q (gpm)
3.0
4
2.5
ΔP in bar
3
ΔP in psi
2.0
2 1.5
1.0
1
0.5
0 0
0 170 340 510 680 850
Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
SF110
SF110 [3.23]
[2.17] 82
55 SF160/240
SF240
4.33
[2.83]
110
72
[0.41]
SF 110: 10.4
1.38
SF 240: 35.1 Adapter
(For NPT Filters)
SF 110 3/4" NPT (2054390) SF110 SF240
SF 240 11/4" NPT (2054389) [5.71] [7.09]
145 180
Clearance required for element
Vacuum indicator port removal
G 1/2"
OUTLET
SF110 SF110
3/4" Threaded
[3.94]
SF240
1 1/4" Threaded 100
SF240
[4.72] SF110
120 [9.17]
233
SF240
SF110 [10.63]
[5.24] 270
SF110 133
[1.73]
44 SF240
[5.91]
SF240
150
[2.13]
54
INLET
SF110
3/4" Threaded SAE-12
SF240
D3
1 1/4" Threaded SAE-20
Mounting pattern
Size SF 110 SF 240
Weight (lbs.) 2.5 5.0
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
5.91 5.91
150 150
3.65
6.3 92.6
6.6
160 167.6
11.06
281 11.06
2.48 281
63 1.06
5.47 5.47
1/2"-13UNC X 27 DP 139
139 4 Places
6.3
3.35 160
6.69 0.35
170 85
9
Uses
M8
2 1/2"-12UN-2B Vacuum
bolts SAE-32 indicator
OUTLET port
5.31 G 1/2"
135
Mounting pattern 2.48
63
11.06
281
5.47
139
INLET
2" NPT
Size SF 330
Weight (lbs.) 9.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
SF 330 HOUSING
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
WIRESCREEN …RS...W/HC
SIZE 74 μm 125 μm
0110 RS XXX W/HC 0.029 0.014
0240 RS XXX W/HC 0.014 0.007
0330 RS XXX W/HC 0.010 0.005
INLET OUTLET
BY-PASS
VALVES
(OPTIONAL)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
[0.78]
1/2"-20UNF-2Bx20 DP
0.16
4
5.91 6.69
150 170
0.79
0.79 20
20
8.27
210
9.02
229
5.87
149 6.85
174
3.81±0.01 3.23
96.8±0.2 82 3.15 3.54 3.23
80 90 82
2.24 0.24 0.16 1.77
57 6 4 45
2" SAE
Code 62 Flange
2 PL'S 2.56
INLET 2.95
65 3.94
75
100
1.75±0.01 7.28
44.5±0.2 185
G 1/2"
Vent Plug
13.64
OUTLET
DFFX 330: 346.5
[1.00]
G 1/2" [20.35]
3/4"-10UNC-2Bx25.3 DP
Clogging DFFX 660: 517
Indicator
Port
G 1/2" 1.42
Drain Plug 36
[4.53]
115 HEX
Clearance required 5.13
for element removal 130.2
9.02
229
2.56
65
2" SAE
Code 62 Flange
2 PL'S
INLET
3.23
82
3.81±0.01
96.8±0.2 [1.00]
3/4"-10UNC-2Bx25.3 DP
1.75±0.01
44.5±0.2
5.79
147 8.27
6.46
164 210
5.08
129 0.24 3.23 0.79
6 82 0.98 20
25
3.15
80 6.10
7.28 2.95 155
185 75
G1/2" Clogging
Indicator OUTLET
Port [13.64]
DFFX 330: 346.5 [0.79]
20.35 1/2"-20UNFx20 DP
DFFX 660: 517 4 PL'S
0.79
0.79 20 20.31
20 DFFX 660: 516
[32.99]
8.27
DFFX 1320: 838
210
9.02
229
G 1/2"
Drain plug
5.87
149
3.15 3.54
3.81±0.01 3.23
80 90 6.85
96.8±0.2 82
0.24 0.16 174 1.77
2.56 2.24 3.23
6 4 45
65 57 82
1.75±0.01
3.94 2.95
44.5±0.2
100 75
7.28
185 G1/2"
Vent plug
G 1/2" 20.04
Clogging OUTLET
DFFX 660: 509
2" SAE Indicator
Code 62 Flange port [32.72]
2 PL'S DFFX 1320: 831
INLET
[1.00]
3/4"-10UNC-2Bx25.3 DP 4.41
112
G1/2" 1.42
Drain plug 36
HEX [13.78]
5.20 DFFX 660: 350 MIN
132 [26.38]
DFFX 1320: 670 MIN
5.98 Clearance required
152 for element removal
3.23
82
3.81±0.01
96.8±0.2
[1.00]
1.75±0.01
3/4"-10UNC-2Bx25.3 DP
44.5±0.2
5.79
147 6.46 8.27
164 210
5.08
0.24 3.23
129 0.79
6 82 0.98
20
25
3.15 2.95
80 75
6.10
7.28 155
G1/2" Clogging 185
Indicator
Port
20.04 OUTLET
[0.79]
DFFX 660: 509 1/2"-20UNFx20 DP
[32.72] 4 PL'S
DFFX 1320: 831
4.41
112
1.42 G1/2"
36 Drain Plug
[13.78]
HEX DFFX 660: 350
5.20 [26.38]
132 DFFX 1320: 670
Clearance required
5.98 for element removal
152
DFFX 330 / 660 / 1320 TL Housing DFFX 330 / 660 / 1320 TLL Housing
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700
25 25
1.6 1.6
Forward
20 20
Forward
1.2 1.2
15 15
Reverse
Reverse
0.8 0.8
10 10
5 0.4 5 0.4
0 0.0 0 0.0
0 40 80 120 160 200 0 40 80 120 160 200
Flow in gpm Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Wire Mesh …D…W/HC Elements Metal Fiber …D…V Elements (High Collapse)
Size 25, 50, 100, 200 µm Size 3 µm 5 µm 10 µm 20 µm
0330 D XXX W/HC 0.008 0330 D XXX V 0.121 0.097 0.065 0.043
0660 D XXX W/HC 0.004 0660 D XXX V 0.063 0.050 0.034 0.021
1320 D XXX W/HC 0.002 1320 D XXX V 0.032 0.026 0.018 0.012
B B
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
d3 t1
∆ P Clogging
Indicator Port t1
INLET
G 1/2" 57 Port
d3
h1
4.14
105.2
Q (l/min) Q (l/min)
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
10 30
2.0
9
0.6
25
8
7 0.5 1.5
20
6
ΔP in bar
ΔP in bar
0.4
ΔP in psi
ΔP in psi
5 15 1.0
0.3
4
10
3 0.2
0.5
2
0.1 5
1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Q (gpm) Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
∆P Elements = Elements (From
(K) Flow Factor x Flow Rate (gpm) x
Tables Below) 141 SUS 0.86
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
6.42 3.23
163 82
1.00
25.4
HEX
10.65 5.08
4.69
270.5 129
119
[12.00]
1.57 HFDK4P-09 305
40 [21.00]
18 533
[30.00]
27 762
Clearance required
Vent Plug 0.88 for element removal
SAE-4 22.4
(7/16-20 UNF)
5.25
133.4
Pressure 18.02
Equalization
Valve HFDK4P-09 457.8
[27.41]
18 696.1
[36.79]
27 934.6
7.87
200
4.02 3.27
102 83
Drain Plug
Dirty side
SAE-8
OUTLET 5.39 (3/4-16UNF) 1.77
137 7.01 5.85
45
178 148.5
8.23
12.80 0.61
209
325 15.6
INLET
1/2"-20UNF-2B x 17DP
3.81
96.8 SAE Flange
2" SAE CODE 62
6.69
170 5.85 3/4"-10UNC-2B
148.5 x 25DP
0.59 1.75
15 44.5
6.89
175
11.61
295
Size 09 18 27
Weight (lbs.) 233.7 270.5 306.4
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
Flow in l/min
0 50 100 150 200 250 300 350
30 2.0
1.8
25
1.6
20 1.4
1.2
15 1.0
0.8
10
0.6
5 0.4
0.2
0 0
0 10 20 30 40 50 60 70 80 90 100
Flow in gpm
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
(From Tables Below) 141 SUS 0.86
12.8
325
6.89 Δ P Clogging
175 indicator port
15.7 G1/2"
APPROX.
Vent Plug
G1/8"
10.63
270
APPROX. 5.91
Lifting holes
[0.67] 150
1/2-20UNF-2B x 17 DP
2.38
60.5
INLET
Indexing plunger SAE 2"
for locking 6000 PSI
the lever
(optional)
0.62
15.7 5.39
0.24 8.94 3.27 137
6 227 83
APPROX.
3.86
7.87 98
200 15.94
Size 08: 405
[21.18]
Size 13: 538.1
0.31 24.72
8 OUTLET Size 16 628
SAE 2"
6000 PSI
5.13 [4.53]
Drain Port
G 1/2" 130.2 115
Clearance required
5.98 for element removal
152
5.98 [16.81]
152 427
Clearance
11.61 0.59 required
4.69 295 15 Inlet/Outlet for element
119 Flange removal
5.08 0.79
20 3.81
129
96.8
8.23
6.69
209
170
3/4-10UNC-2B x
1.75
0.67 [0.98] Min.
1.42 44.5 25 Full Thread
1/2-20UNF-2B X 17 DP 3.23 36 Hex 4 PL's
4 Pls 82
9.65
245
Size 08 13 16
Dimensions are [inches] millimeters
Weight (lbs.) 225.3 250.6 284.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
6.43 3.23
163.3 82
0.39
10
1.42
5.08 36 HEX
129
PRESSURE EQUALIZATION
VALVE
1.57
40 6.5
165 [8.19]
SIZE: 08 - 208 MIN
[12.95]
13 - 329 MIN
[16.81]
VENT PLUG 16 - 427 MIN
G 1/2 5.98 CLEARANCE
HEX 10 152 FOR ELEMENT
REMOVAL
5.87 [16.1]
149 SIZE 08: 409
20.94
SIZE 13: 532
5.2 [24.73]
0.98 132 SIZE 16: 628
3/4-10UNC-2Bx 25 DP
4PLS
1.75±0.01
44.5±0.2 8.94
~ 227 7.87
OUTLET 200
SAE 2"
6,000 PSI
INLET
SAE 2", 6000 PSI 6.89
175
2.38
0.79
60.5
20
6.69
170
0.67
1/2-20UNF-2Bx 17 DP 11.61 0.59
4PLS 295 15
Size 08 13 16
Weight (lbs.) 239.4 266.2 297.9
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.
For complete dimensions please contact HYDAC to request a certified print.
HFDK3P Housing
Q (l/min)
0 100 200 300 400 500 600
30
2.0
25
1.5
20
ΔP in bar
ΔP in psi
15 1.0
10
0.5
5
0 0
0 20 40 60 80 100 120 140 160
Q (gpm)
Element K Factors
Actual Viscosity (SUS) x Actual Specific Gravity
P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
(From Tables Below) 141 SUS 0.86
Clogging Indicators
Early warning pressure devices protect the hydraulic circuit from
contamination, alerting the operator that the filter element is near capacity
and must be changed. The clogging indicator is typically set to trip at 1-bar
(14 psid) below the filter bypass setting, to allow the operator sufficient time
for element change-out. Available in visual, combo electrical/visual, as well
as an extensive list of other options and certifications. A comprehensive
offering of clogging indicators ensures that any application can be
accommodated.
Introduction I2
General Indicator Type
I4
Drawings
Standard Indicators
Vacuum I6
Return line I8
Differential pressure I21
Mobile Indicators
Return line I29
Differential pressure I30
ATEX Indicators
Return line I32
Differential pressure I34
UL/CSA Indicators
Return line I36
Differential pressure I36
Model Code - Standard I38
Dual Indicator / Gauge Blocks I40
Indicator Installation
I42
Information for Filters
Cap
Spring
Piston
Profile Seal
Spring
Housing
Piston
O-ring
High Pressure Side (before element - dirty side)
Plug Low Pressure Side (after element - clean side)
Standard without
Dome Cap;
Indicator pin (Red) (For Indicator with optional
Dome Cap contact HYDAC)
Piston
Housing
Spring
Diaphragm
O-ring
Threaded Body
Fluid Port
High Pressure Side (before element - dirty side)
VR x UE.x
Type of indication Visual-analog, scale indication [ø1.97]
Weight 0.28 lbs (125 g) ø50
Trip Pressure / Range use w/3 psi (0.2 bar) bypass valve
Permitt. operating pressure -30 inHg to 0 inHg
[1.20]
Permitt. temperature range -40°F to 200°F (-40°C to 93°C) 30.5
[1.84]
Thread 1/8” NPTF 46.8
Max. torque Refer to end of section H HEX 14
Switching type –
1/8 NPTF
Max. switching voltage –
Electrical connection –
Max. switching voltage at
–
resistive load
Switching capacity –
Protection class to DIN 40050 –
Order example VMF0.2UE.0/3
VMF x UF.x
Type of indication Electrical switch [ø1.26]
Weight 0.37 lbs (170 g) ø32
VR x UF.x
Type of indication Electrical switch [ø1.26]
Weight 0.37 lbs (170 g)
ø32
VR x B.x
Type of indication visual, red pin
Weight 0.10 lbs (44 g)
29 psi -2.9 psi [ø0.39]
Trip Pressure / Range*
(2 bar -0.2 bar) [~0.20] ø10
~5 Hub
Permitt. operating pressure 102 psi (7 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H [~1.87]
~47.5
[~2.34]
Switching type – ~59.5
HEX 30
Max. switching voltage –
Electrical connection –
Max. switching voltage at
–
resistive load [0.47]
Switching capacity – G1/2 12
VMF x C.x
Type of indication Electrical switch
Weight 0.60 lbs (270 g)
29 psi -4.4 psi (2 bar -0.3 bar)
Trip Pressure / Range*
73 psi -7.3 psi (5 bar -0.5 bar)
[~1.34] [1.10]
Permitt. operating pressure 580 psi (40 bar) ~34 28
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VR x D.x /-L…
Type of indication Visual indicator & electrical switch
Weight 0.79 lbs (360 g)
29 psi -4.4 psi (2 bar -0.3 bar)
Trip Pressure / Range*
73 psi -7.3 psi (5 bar -0.5 bar)
[*1.10] [~1.34]
Permitt. operating pressure 580 psi (40 bar) *28 ~34
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VR x D.x /-LED
Type of indication Visual indicator & electrical switch
Weight 0.79 lbs (360 g)
29 psi -4.4 psi (2 bar -0.3 bar)
Trip Pressure / Range*
73 psi -7.3 psi (5 bar -0.5 bar) [*1.10] [~1.34]
*28 ~34
Permitt. operating pressure 580 psi (40 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H
[~4.23] [~3.07]
Switching type N/O contact ~107.5 ~78
VMF x E.x
Type of indication Visual-analog, scale indication
[ø1.97]
Weight 0.12 lbs (54 g) ø50
VR x E.x
Type of indication Visual-analog, scale indication [ø1.97]
Weight 0.28 lbs (125 g) ø50
VMF x ES.x
Type of indication Visual-analog, scale indication
[1.18]
Weight 0.12 lbs (54 g) 30
Switching type –
Max. switching voltage – [0.39]
G 1/8
10
Electrical connection – *12
VMF x F.x
Type of indication Electrical switch [ø1.26]
ø32
Weight 0.15 lbs (70 g)
29 psi ±4.4 psi
Trip Pressure / Range
(2 bar ±0.3 bar)
Permitt. operating pressure 580 psi (40 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/8
Max. torque Refer to end of section H [~3.44]
Switching type N/O contact (N/C as an option) ~87.5
VR x F.x
Type of indication Electrical switch [ø1.26]
ø32
Weight 0.29 lbs (130 g)
29 psi ±4.4 psi
Trip Pressure / Range
(2 bar ±0.3 bar)
Permitt. operating pressure 580 psi (40 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H
[~4.11]
Switching type N/O contact (N/C as an option) ~104.5
Thread G 1/2
[~5.02] [~6.00]
Max. torque Refer to end of section H ~127.5 ~152.5
N/C or N/O, electronic, PNP
Switching type positive switching (factory setting) HEX 30
Max. switching voltage Operating voltage 20-30 V DC
Electrical connection 7 pole plug to DIN 43651, PG 11
Max. switching voltage at G1/2 [0.47]
12 W 12
resistive load [ø1.81]
ø46
Switching capacity Ohmic 0.4 A at 30 V =
IP 65 (only if the connector is wired
Protection class to DIN 40050 and fitted correctly)
Order example VR 2 GC.0 /-LED-SQ-123
VMF x J.x
Type of indication Electrical switch
Weight 0.66 lbs (300 g)
29 psi -4.4 psi (2 bar -0.3 bar) [~ 1.77]
Trip Pressure / Range* ~ 45
73 psi -7.3 psi (5 bar -0.5 bar) [ 1.06]
Permitt. operating pressure 580 psi (40 bar) 27
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VMF x J4.x
Type of indication Electrical switch
Weight 0.60 lbs (270 g)
[~ 1.59]
29 psi -4.4 psi (2 bar -0.3 bar) ~ 40.5
Trip Pressure / Range* [*1.06]
73 psi -7.3 psi (5 bar -0.5 bar) *27
Permitt. operating pressure 580 psi (40 bar)
Permitt. temperature range -13˚F to 185˚F (-25˚C to 85˚C)
Thread G1/8
Max. torque Refer to end of section H
Switching type N/C or N/O (change-over contacts) [~ 3.76] [~ 2.58]
~ 95.5 ~ 65.5
Max. switching voltage 230V
12mm (Micro) connector (4 PIN);
Electrical connection HEX 27
A Female connector to DIN 43650
1 Max. switching voltage at 250W=
2 resistive load 300VA~
p 2 Ohmic 6A at 24V=
1 Switching capacity
3 Ohmic 0.03 to 6A at max. 230V~ [0.39]
3 G 1/8
4 IP 65 (only if the connector is wired 10
Protection class to DIN 40050
and fitted correctly)
B Order example VMF 2 J4.1
VR x J4.x
Type of indication Electrical switch
[~ 1.59]
Weight 0.75 lbs (340 g) ~ 40.5
[1.06]
29 psi -4.4 psi (2 bar -0.3 bar) 27
Trip Pressure / Range*
73 psi -7.3 psi (5 bar -0.5 bar)
Permitt. operating pressure 580 psi (40 bar)
Permitt. temperature range -13˚F to 185˚F (-25˚C to 85˚C)
Thread G1/2
Max. torque Refer to end of section H
[~ 4.04] [~ 3.05]
Switching type N/C or N/O (change-over contacts) ~ 102.5 ~ 77.5
Max. switching voltage 230V
12mm (Micro) connector (4 PIN);
Electrical connection
A Female connector to DIN 43650
1 Max. switching voltage at 250W= HEX 19
2 resistive load 300VA~
p 2
1 Ohmic 6A at 24V=
3 Switching capacity Ohmic 0.03 to 6A at max. 230V~
3
4 IP 65 (only if the connector is wired
Protection class to DIN 40050 [0.55]
and fitted correctly) 14 G 1/2
B Order example VR 2 J4.1
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VR x LE.x
Visual (red pin) & electrical switch
Type of indication [~3.12]
(100% activation) ~79
Weight 0.32 lbs (143 g)
Trip Pressure / Range* 29 psi -2.9 psi (2 bar -0.2 bar)
Permitt. operating pressure 102 psi (7 bar)
[~1.34]
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C) ~34
VMF x LZ.x
Visual (red pin) & electrical switch
Type of indication
(75% & 100% activation)
Weight 0.51 lbs (230 g)
[~4.86]
Trip Pressure / Range* 29 psi -2.9 psi (2 bar -0.2 bar) ~123
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VR x LZ.x /-DB
Visual (red pin) & electrical switch
Type of indication (75% & 100% activation). 3 LEDs
(grn=power, yel=75%, red=100%)
[~3.39]
Weight 0.42 lbs (190 g) ~86 PG 11
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
4 [0.39]
Ohmic 1 A at 15 V = 10
+ Switching capacity
P 2 Ohmic 1 A at 15 V ~ G 1/8 [0.47]
12
Yellow
IP 65 (only if the connector is wired
3 Protection class to DIN 40050
Switch
Warning Green and fitted correctly)
75% 1
Order example VMF 2 LZ.1 /-CN
VR x LZ.x /-CN
Visual (red pin) & electrical switch
Type of indication (75% & 100% activation). 3 LEDs
(grn=pwr, yel=75%, red=100%)
[~3.39]
Weight 0.42 lbs (190 g) ~86 PG 11
*When presented as a pressure followed by a negative (ex 29 psi -4.4 psi), the 4.4 is the lower tolerance. This is not to be interpreted as a range (ex 4.4 - 29 psi).
The range in this instance would be 24.6 - 29 psi. Indicators are not field adjustable.
VR x LZ.x /-AV
Visual (red pin) & electrical switch
Type of indication
(75% & 100% activation)
Weight 0.32 lbs (145 g)
29 psi (or 36 psi) -10% [2.87]
Trip Pressure / Range
2 bar (or 2.5 bar) -10% 73
[*1.38]
Permitt. operating pressure 102 psi (7 bar) *35
Switch
Warning
75%
Order example VMF 2 LZ.1 /-D4C
VR x LZ.x /-D4C
Electrical switch (75% & 100%
activation) w/30˚C thermal lockout.
Type of indication
4 LEDs (grn=pwr, blue=
below 86˚F, yel=75%, red=100%)
Weight 0.45 lbs (205 g) [1.65]
42
Trip Pressure / Range 36 psi -10% (2.5 bar -10%)
Permitt. operating pressure 102 psi (7 bar)
[~2.72]
Permitt. temperature range 14˚F to 212˚F (-10°C to 100°C) ~69
[2.09]
Thread G 1/2 ~53
+24V 0V V A-
Max. torque Refer to end of section H
M12x1
1 3 4 2 Switching type N/O (75%), N/C (100%)
HEX 30 [~3.28]
Max. switching voltage 24 V [~1.48] ~83
Grn Yel Blue Red
~37.5
Electrical connection Male connection M12 x 1 LEDs [1.02]
26
Max. switching voltage at 15 W =
Schematic with
resistive load max. 15 VA ~ G 1/2
Temperature [0.47]
switch activated
Ohmic 1 A at 15 V = 12
Switching capacity
(<30˚C)
Switch
Ohmic 1 A at 15 V ~
Alarm
Switch
Warning
75%
Order example VR 2 LZ.1 /-D4C
M21x1
Switching type N/O (75%), N/C (100%)
[~ 2.80]
Max. switching voltage 24 V
~ 71
100% alarm
2
Electrical connection Male connection M12 x 1
[1.48]
P
37.5
LEDs
4 Max. switching voltage at 15 W = HEX 30
red resistive load max. 15 VA ~
P 1 +24v Ohmic 1 A at 15 V =
yellow Switching capacity
green Ohmic 1 A at 15 V ~ [0.47]
G 1/2
3 0v 12
Protection class to DIN 40050 IP 65
75% warning
VD x B.x
Visual, red/green band
Type of indication [ø1.06]
automatic reset
ø27
Weight 0.24 lbs (110 g)
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 6000 psi 420 bar
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
[~2.50]
Max. torque Refer to end of section H *27
~63.5
Switching type -
Max. switching voltage -
Electrical connection - [1.06]
27
Max. switching voltage at
-
resistive load
Switching capacity -
Protection class to DIN 40050 - G 1/2
Order example VD 5 B.1
VM x BM.x
Visual, red/green band
Type of indication
manual reset
Weight 0.12 lbs (55 g) [ø1.06] [0.20]
ø27 5 Stroke
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 3000 psi (210 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H [~2.72]
HEX 30 ~69
Switching type -
Max. switching voltage -
[1.06]
Electrical connection -
27
Max. switching voltage at
-
resistive load
Switching capacity -
G 1/2
Protection class to DIN 40050 -
Order example VM 5 BM.1
VM x C.x
Type of indication Electrical switch
Weight 0.26 lbs (120 g) [~1.33]
~34
29 psi -10% (2 bar -10%) [*1.09]
Trip Pressure / Range 73 psi -10% (5 bar -10%) *28
116 psi ±10% (8 bar ±10%) M20x1.5
Permitt. operating pressure 3000 psi (210 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H [~2.63]
*30
~67
Switching type N/C or N/O (change-over contacts) [~4.15]
~106
Max. switching voltage 230 V
Male connection M20
Electrical connection
Female connector to DIN 43650
Max. switching voltage at 60 W =
resistive load 100 VA ~ [1.06]
27
Ohmic 3 A at 24 V =
Switching capacity*
Ohmic 0.03 to 5 A at max. 230 V ~
IP 65 (only if the connector is wired
Protection class to DIN 40050 G 1/2
and fitted correctly)
Order example VM 5 C.0
VD x C.x
Type of indication Electrical switch
[~1.33]
Weight 0.49 lbs (220 g) ~34
[*1.09]
29 psi -10% (2 bar -10%) *28
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%) M20x1.5
Permitt. operating pressure 6000 psi (420 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H
*30 [~2.63]
Switching type N/C or N/O (change-over contacts) [~4.15]
~67
~105.5
Max. switching voltage 230 V
Male connection M20
Electrical connection
Female connector to DIN 43650
Max. switching voltage at 60 W =
resistive load 100 VA ~ [1.06]
Ohmic 3 A at 24 V = 27
Switching capacity*
Ohmic 0.03 to 5 A at max. 230 V ~
IP 65 (only if the connector is wired
Protection class to DIN 40050
and fitted correctly) G 1/2
Order example VD 5 C.0
*Required amperage > 20 mA; for lower amperages, order “-SO135” indicators (see Supplementary Details in the Model Code).
VD x D.x/-L…
Type of indication Visual indicator & electrical switch
[~1.34]
Weight 0.55 lbs (250 g) ~34
[*1.10]
29 psi -10% (2 bar -10%) *28
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%) M20x1.5
Permitt. operating pressure 6000 psi (420 bar)
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C)
Thread G 1/2
Max. torque Refer to end of section H
*30 [~2.65]
Switching type N/C or N/O (change-over contacts) [~4.32] ~67
~110
24, 48, 115, 230 V
Max. switching voltage
(depending on the type of light insert)
1 p
Male connection M20
2 Electrical connection
3
Female connector to DIN 43650
Max. switching voltage at 60 W =
resistive load 100 VA ~ [1.06]
R
Ohmic 3 A at 24 V = 27
Switching capacity*
Ohmic 0.03 to 5 A at max. 230 V ~
Connection
IP 65 (only if the connector is wired
block
5 Protection class to DIN 40050
and fitted correctly)
G 1/2
Order example VD 5 D.0 /-L24
VM x D.x/-LED
Type of indication Visual indicator & electrical switch
[~1.34]
Weight 0.33 lbs (150 g) ~34
29 psi -10% (2 bar -10%) [*1.10]
*28
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%) M20x1.5
VL x GW.x
Electronic / Analog, (4-20 mA)
Type of indication 1 switch contact at 75% and
at 100% trip pressure [ø1.81]
ø46
Weight 0.35 lbs (157 g)
M12x1
29 psi ±5% 44 psi ±5% 73 psi ±5%
Pressure setting (100%) (2 bar ±5%) (3 bar ±5%) (5 bar ±5%)
0 - 73 psi 0 - 73 psi 0 - 116 psi
Indication range ∆p (0 - 5 bar) (0 - 5 bar) (0 - 8 bar) [0.46]
11.6
Indication range (p before filter) 363 psi (25 bar)
El. switch, PNP positive switching
Switching type (output ∆p)
N/C or N/O contacts (factory set.)
Output load 400 mA
Max. switching 20 - 30V DC
operating voltage [3.58]
Analog outputs 4 - 20 mA (max. load resistance 91
(p before filter & ∆p) 600Ω) HEX 27
Electrical connection M12x1/8 pole
Protection class to DIN 40050 IP 65
Permitt. operating pressure 25 bar [1.06]
27
Permitt. temperature range -40˚F to 185˚F (-40°C to 85°C)
Thread G 1/2
Max. torque Refer to end of section H G 1/2
VD x J.x
Type of indication Electrical switch
Weight 0.55 lbs (250 g) [~ 1.77]
29 psi -10% (2 bar -10%) ~ 45
[*1.06]
Trip Pressure / Range 73 psi -10% (5 bar -10%) *27
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 6000 psi (420 bar)
Permitt. temperature range -13˚F to 185˚F (-25˚C to 85˚C)
Thread G 1/2
Max. torque Refer to end of section H HEX 30 [~ 2.38]
[~ 3.96] ~ 60.5
Switching type N/C or N/O (change-over contacts) ~ 100.5
Max. switching voltage 230V
7/8” (Mini) connector (5 PIN);
A Electrical connection
Female connector to DIN 43650
2 Max. switching voltage at 60W=
p 2 RED [1.06]
1 WHITE resistive load 100VA~ 27
1 Ohmic 3A at 24V=
3 ORANGE Switching capacity
4 Ohmic 0.03 to 5A at max. 230V~
GREEN 3 Protection class to DIN 40050 IP 65 (only if the connector is wired G 1/2
B BLACK and fitted correctly)
5
Order example VD 5 J.1
VM x J4.x
Type of indication Electrical switch
Weight 0.26 lbs (120 g) ~ [1.59]
~ 40.5
29 psi -10% (2 bar -10%) [*1.06]
*27
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 3000 psi (210 bar)
Permitt. temperature range -13˚F to 185˚F (-25˚C to 85˚C)
Thread G 1/2
Max. torque Refer to end of section H [~ 3.96] HEX 30 [~ 2.46]
~ 100.5 ~ 62.5
Switching type N/C or N/O (change-over contacts)
Max. switching voltage 230V
12mm (Micro) connector (4 PIN);
A Electrical connection
1 Female connector to DIN 43650
2 Max. switching voltage at 60W=
p 2 [1.06]
1 resistive load 100VA~ 27
3 Ohmic 3A at 24V=
3 Switching capacity
4 Ohmic 0.03 to 5A at max. 230V~
IP 65 (only if the connector is wired
Protection class to DIN 40050 G 1/2
and fitted correctly)
B
Order example VM 5 J4.1
VD x LE.x
Visual (red pin) & electrical switch
Type of indication
(100% activation) [~3.12]
~79
Weight 0.44 lbs (198 g)
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi (8 bar) - Consult HYDAC
Permitt. operating pressure 6000 psi (420 bar) [~1.34]
~34
Permitt. temperature range 14˚F to 212˚F (-10°C to 100°C)
[1.38]
Thread G 1/2 35 M20x1.5
VD x LZ.x
Visual (red pin) & electrical switch
Type of indication
(75% & 100% activation)
Weight 0.53 lbs (240 g)
29 psi -10% (2 bar -10%) [~4.86]
~123
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi (8 bar) - Consult HYDAC
Permitt. operating pressure 6000 psi (420 bar)
[~1.34]
Permitt. temperature range 14˚F to 212˚F (-10°C to 100°C) ~34
VD x LZ.x /-CN
Visual (red pin) & electrical switch
Type of indication (75% & 100% activation). 3 LEDs
(grn=pwr, yel=75%, red=100%)
Weight 0.54 lbs (245 g) [~3.39] PG 11
~86
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi (8 bar) - Consult HYDAC [2.35]
Permitt. operating pressure 6000 psi (420 bar) max. 60
VD x LZ.x /-BO
Visual (red pin) & electrical switch
Type of indication (75% & 100% activation)
Weight 0.43 lbs (197 g) [2.87]
29 psi -10% (2 bar -10%) 73
Trip Pressure / Range 73 psi -10% (5 bar -10%) [*1.38]
116 psi (8 bar) - Consult HYDAC *35
4
Electrical connection Male connection M12 x1
[1.06]
Max. switching voltage at 15 W = 27
P 1 resistive load max. 15 VA ~
Ohmic 1 A at 15 V =
3 Switching capacity Ohmic 1 A at 15 V ~ G 1/2
Switch:
Warning 75% Protection class to DIN 40050 IP 65
B Order example VD 5 LZ.1 /-AV
VD x LZ.x /-D4C
Electrical switch (75% & 100%
activation) w/30˚C thermal lockout.
Type of indication
4 LEDs (grn=pwr, blue=
below 86˚F, yel=75%, red=100%)
Weight 0.56 lbs (256 g) [1.65]
42
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi (8 bar) - Consult HYDAC
Permitt. operating pressure 6000 psi (420 bar)
[2.72]
Permitt. temperature range 14˚F to 212˚F (-10°C to 100°C) ~69 [2.13]
+24V 0V V A-
54
Thread G 1/2
1 3 4 2
Max. torque Refer to end of section H
M12x1
Switching type N/O (75%), N/C (100%) [2.40]
Grn Yel Blue Red
~61
Max. switching voltage 24 V
[1.06]
~27
Electrical connection Male connection M12 x1 HEX 30
Schematic with
Max. switching voltage at 15 W =
max. 15 VA ~ LEDs [1.06]
Temperature
switch activated resistive load 27
(<30˚C)
Ohmic 1 A at 15 V =
Switching capacity
Switch Ohmic 1 A at 15 V ~
Alarm
100% G 1/2
Switch
Protection class to DIN 40050 IP 65
Warning
VD x LZ.x /-BO-LED
Electrical switch (75% & 100%
Type of indication activation). 3 LEDs (grn=pwr,
yel=75%, red=100%)
Weight 0.55 lbs (250 g) [1.65]
42
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi (8 bar) - Consult HYDAC
Permitt. operating pressure 6000 psi (420 bar)
[2.72]
Permitt. temperature range 14˚F to 212˚F (-10°C to 100°C) ~69 [2.13]
Thread G 1/2 54
VR x FD.x
Type of indication Electrical switch
[ø0.98]
Weight 0.20 lbs (90 g) ø25
Ohmic 2.5 A at 24 V =
Switching capacity
Ohmic 1 A at 220 V ~
IP 67 (only if the connector is wired
Protection class to DIN 40050 [0.55]
and fitted correctly) 14
G 1/2
Order example VR 2 FD.0 /-2M0
VM x CD.x
Type of indication Electrical switch
Weight 0.22 lbs (100 g)
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 3000 psi (210 bar)
HEX 30 [~2.73]
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C) ~69
[1.87]
Thread G 1/2 47.5
VD x CD.x
Type of indication Electrical switch
Weight 0.43 lbs (195 g)
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 6000 psi (420 bar)
HEX 30 [~2.73]
Permitt. temperature range -22˚F to 212˚F (-30°C to 100°C) ~69
[1.87]
Thread G 1/2 47.5
B…CMF*
Type of indication Single pole (ground switching)
Weight 0.05 lbs (24 g) [0.88]
22.4
Trip Pressure / Range 44 psi +6 psi (3 bar +0.4 bar)
Permitt. operating pressure 3000 psi (210 bar)
Permitt. temperature range 22˚F to 200˚F (-30°C to 93°C)
#8-32 thread post
connector
Thread SAE-8 differential port
Max. torque Refer to end of section H [0.90]
22.9
Switching type N/O
Max. switching voltage –
Electrical connection #8 - 32 threaded post
Max. switching voltage at
–
resistive load
Switching capacity ohmic 200MA at 36VDC
Chassis Protection class to DIN 40050 Terminals IP00
Ground
3/4"-16UNF-2B
Order example B3420CMF.0
Red Pop-up
A Electrical connection Female connector to DIN 43650 Indicator
Max. switching voltage at
3 –
p resistive load
ohmic 5A at 125/250VAC,
Switching capacity
1 5A at 24VDC
Protection class to DIN 40050 IP60
B 2
3/4"-16UNF-2B
Order example B3420LEMF.0
*This clogging indicator is for use with the MF/MFD/MFDS Series only.
VD x C.x /-2GEXDIIC
Type of indication Electrical switch
Weight 1.32 lbs (600 g)
29 psi -10% (2 bar -10%)
Trip Pressure / Range 73 psi -10% (5 bar -10%)
116 psi ±10% (8 bar ±10%)
Permitt. operating pressure 6000 psi (420 bar)
-4˚F to 140˚F (-20°C to 60°C)
Permitt. temperature range HEX 24
setting (media temp. max. 75° C)
Thread G 1/2 [~4.53]
~115
Max. torque Refer to end of section H [~3.48]
~89
Switching type Change-over [2.34]
59.5
Max. switching voltage 250 V
HEX 30 [0.79]
Electrical connection Cable connection 20
Max. switching voltage at 60 W =
resistive load 100 VA ~ [1.06]
27
ohmic 3 A at 24 V =
Switching capacity
ohmic 0.03 A to 5 A at 250 V ~
G1/2
Protection class to DIN 40050 IP 66
[ø1.38]
ATEX designation ø35
II 2G Ex d IIC T6
Order example VD 2 C.1 /-2GEXDIIC
Supplementary Details for “GC” type Discontinued (consult HYDAC for suitable replacements)
SP = Analog signal: output 1-10 V if SP or SQ are not specified
SQ = Analog signal: output 4-20 mA (current source) “current sink” model supplied
113 = N/O function - pressure peak suppression up to 10 sec.
Cold start suppression of switching outputs
(PNP technique, positive switching) up to 25°C Must be specified!
123 = N/C function - p ressure peak suppression up to 10 sec. Others on request
Cold start suppression of switching outputs
(PNP technique positive switching) up to 25°C
30C = Cold start suppression of switching outputs up to 30°C (other temperatures on request)
LED = 3 LED‘s (green, yellow, red) in terminal box
PF = Floating switching outputs (due to relay in the plug)
Notes: 1. Old style indicators for filters HF2P / HF3P / HF4P - pre 2008 (Example Model Code: B2210BHF), contact HYDAC for further information.
2. VMF indicators of type B, LE, LZ, and C I-EX2G, must include “V” at the end of the Model Code if Fluorocarbon elastomer (FKM) seals are required. All
other VMF indicators come with Fluorocarbon elastomer (FKM) seals as a standard (no Supplementary Detail required).
SECTION
G 1/2
SECTION
3/4-16UNF-2A
Adapter - Static - G 1/2” to G 1/8” Adapter - Static - G 1/8” to G 1/2” Pipe Connection Block - SAE-4 Ports
(Part No. 319004 w/NBR seal) (Part No. 318740) to G1/2 Differential Indicator Port
(Part No. 02080588)
HEX 19 [2.00]
HEX 36 50.8
[0.79 -0.04]
20 -1
[1.50]
38.1
[2.36]
60
[1.50]
G 1/2 G 1/2 38
[1.26]
[1.69] 32
[0.28]
43 7
G 1/2
Dual Indicator Block- Differential - G 1/2 Indicator Port to 2 x G 1/2 Indicator Ports
(Part No. 00318732 with NBR seals)
[3.43]
87
[1.97]
50 [1.57]
G 1/2 G 1/2 40
[2.36]
60
[3.43]
87 [0.79]
20
G 1/2
APPLICABLE
UF/UFJ sealant.
A 37 37 24
B/BM 11 11 11
C/CM
D
37 37 24
E/ES
F/FA/FD/FF/FJ/FM/FS
Elastomeric seal
VR GC* 7.5
11 11 11 included.
LE/LEC/LEM/LZ
K
R/RS
UC/UCM 37 37 24
UE/UED
UF/UFJ
C/CM
D
E/ES
K
Elastomeric seal
VRD F/FA/FD/FF/FJ/FM/FS 37 37 24 7.5
included.
R/RS
UC/UCM
UE/UED
UF/UFJ
A 37 37 24 7.5
B/BM
NOT
C/CA/CC/CD/CJ/CM/CS/CW
APPLICABLE
D
NOT
B/BM (W Option) APPLICABLE
74 74
C/CA/CC/CD/CJ/CM/CS/CW Elastomeric seal
VD
(W Option) included.
DIFFERENTIAL INDICATORS
D (W Option)
24
GC*
LE/LEC/LEM/LZ
7.5
MB/MBM 37 37
MC/MCD/MCJ
NOT
BF 0.5 0.5 0.5 Elastomeric seal
VL APPLICABLE
included.
GW 24 24 24 7.5
B/BM
C/CA/CC/CD/CJ/CM/CS/CW
D
Elastomeric seal
VM GM 24 24 24 7.5
included.
M
MB/MBM
MC/MCD/MCJ
B
Elastomeric seal
B…MF LE* N/A N/A 24 N/A
included.
C
This drawing is PROPRIETARY. Distribution, reproduction or disclosure of information pertaining to this drawing to any party other than those
directly working with HYDAC is strictly prohibited without the written consent of HYDAC.
D
J E
F-TAP X G-DEEP
B M (4 PLACES)
K A
C H
j c
u
Ø d1-TAP X t1-DEEP
v x (4 PLACES)
z Ød3
w y
m
j c j f
t g t
a
a 0.0625
k
k 0.0625 1.6
o 1.6 o
B1 A
S
L C2
L
C1 K
K
D
D
# OF
DN D K L BOLT SIZE A B1 C1 C2 S
BOLTS
(3.54) (2.36) (0.55) (0.68) (0.71) (0.55) (0.63) (0.07)
10 4 M12
90 60 14 17.2 18 14 16 1.8
(3.74) (2.56) (0.55) (0.84) (0.87) (0.55) (0.63) (0.08)
15 4 M12
95 65 14 21.3 22 14 16 2
(4.13) (2.95) (0.55) (1.06) (1.08) (0.63) (0.71) (0.09)
20 4 M12
105 75 14 26.9 27.5 16 18 2.3
(4.53) (3.35) (0.55) (1.33) (1.36) (0.63) (0.71) (0.10)
25 4 M12
115 85 14 33.7 34.5 16 18 2.6
(5.51) (3.94) (0.71) (1.67) (1.71) (0.71) (0.71) (0.10)
32 4 M16
140 100 18 42.4 43.5 18 18 2.6
(5.91) (4.33) (0.71) (1.90) (1.95) (0.71) (0.71) (0.10)
40 4 M16
150 110 18 48.3 49.5 18 18 2.6
(6.5) (4.92) (2.37) (2.42) (0.79) (0.71) (0.11)
50 (0.71) 18 4 M16
165 125 60.3 61.5 20 18 2.9
(7.28) (5.71) (0.71) (3.00) (3.05) (0.79) (0.71) (0.11)
65 8 M16
185 145 18 76.1 77.5 20 18 2.9
(7.87) (6.30) (0.71) (3.50) (3.56) (0.79) (0.79) (0.13)
80 8 M16
200 160 18 88.9 90.5 20 20 3.2
(8.66) (7.09) (0.71) (4.50) (4.57) (0.87) (0.79) (0.14)
100 8 M16
220 180 18 114.3 116 22 20 3.6
(9.84) (8.27) (0.71) (5.50) (5.57) (0.87) (0.87) (0.16)
125 8 M16
250 210 18 139.7 141.5 22 22 4
(11.22) (9.45) (0.87) (6.63) (6.71) (0.94) (0.87) (0.18)
150 8 M20
285 240 22 168.3 170.5 24 22 4.5
(13.39) (11.61) (0.87) (8.63) (8.72) (1.02) (0.94) (0.25)
200 12 M20
340 295 22 219.1 221.5 26 24 6.3
(15.94) (13.98) (1.02) (10.75) (10.89) (1.14) (1.02) (0.25)
250 12 M24
405 355 26 273 276.5 29 26 6.3
(18.11) (16.14) (1.02) (12.75) (12.89) (1.26) (1.10) (0.28)
300 12 M24
460 410 26 323.9 327.5 32 28 7.1
B1 A
S
L C2
L
C1 K
K
D
D
# OF
DN D K L BOLT SIZE A B1 C1 C2 S
BOLTS
(3.54) (2.36) (0.55) (0.68) (0.71) (0.55) (0.63) (0.07)
10 4 M12
90 60 14 17.2 18 14 16 1.8
(3.74) (2.56) (0.55) (0.84) (0.87) (0.55) (0.63) (0.08)
15 4 M12
95 65 14 21.3 22 14 16 2
(4.13) (2.95) (0.55) (1.06) (1.08) (0.63) (0.71) (0.09)
20 4 M12
10ww5 75 14 26.9 27.5 16 18 2.3
(4.53) (3.35) (0.55) (1.33) (1.36) (0.63) (0.71) (0.10)
25 4 M12
115 85 14 33.7 34.5 16 18 2.6
(5.51) (3.94) (0.71) (1.67) (1.71) (0.71) (0.71) (0.10)
32 4 M16
140 100 18 42.4 43.5 18 18 2.6
(5.91) (4.33) (0.71) (1.90) (1.95) (0.71) (0.71) (0.10)
40 4 M16
150 110 18 48.3 49.5 18 18 2.6
(6.50) (4.92) (0.71) (2.37) (2.42) (0.79) (0.79) (0.11)
50 4 M16
165 125 18 60.3 61.5 20 20 2.9
(7.28) (5.71) (0.71) (3.00) (3.05) (0.87) (0.87) (0.11)
65 8 M16
185 145 18 76.1 77.5 22 22 2.9
(7.87) (6.3) (0.71) (3.50) (3.56) (0.94) (0.94) (0.13)
80 8 M16
200 160 18 88.9 90.5 24 24 3.2
(9.25) (7.48) (0.87) (4.50) (4.57) (1.02) (0.94) (0.14)
100 8 M20
235 190 22 114.3 116 26 24 3.6
(10.63) (8.66) (1.02) (5.50) (5.57) (1.10) (1.02) (0.16)
125 8 M24
270 220 26 139.7 141.5 28 26 4
(11.81) (9.84) (1.02) (6.63) (6.71) (1.18) (1.10) (0.18)
150 8 M24
300 250 26 168.3 170.5 30 28 4.5
(14.17) (12.2) (1.02) (8.63) (8.72) (1.26) (1.18) (0.25)
200 12 M24
360 310 26 219.1 221.5 32 30 6.3
(16.73) (14.57) (1.18) (10.75) (10.89) (1.38) (1.26) (0.28)
250 12 M27
425 370 30 273 276.5 35 32 7.1
(19.09) (16.93) (1.18) (12.75) (12.89) (1.50) (1.34) (0.31)
300 16 M27
485 430 30 323.9 327.5 38 34 8
B1 A
S
L C2
L
C1 K
K
D
D
# OF
DN D K L BOLT SIZE A B1 C1 C2 S
BOLTS
(3.54) (2.36) (0.55) (0.68) (0.71) (0.55) (0.63) (0.07)
10 4 M12
90 60 14 17.2 18 14 16 1.8
(3.74) (2.56) (0.55) (0.84) (0.87) (0.55) (0.63) (0.08)
15 4 M12
95 65 14 21.3 22 14 16 2
(4.13) (2.95) (0.55) (1.06) (1.08) (0.63) (0.71) (0.09)
20 4 M12
105 75 14 26.9 27.5 16 18 2.3
(4.53) (3.35) (0.55) (1.33) (1.36) (0.63) (0.71) (0.10)
25 4 M12
115 85 14 33.7 34.5 16 18 2.6
(5.51) (3.94) (0.71) (1.67) (1.71) (0.71) (0.71) (0.10)
32 4 M16
140 100 18 42.4 43.5 18 18 2.6
(5.91) (4.33) (0.71) (1.90) (1.95) (0.71) (0.71) (0.10)
40 4 M16
150 110 18 48.3 49.5 18 18 2.6
(6.50) (4.92) (0.71) (2.37) (2.42) (0.79) (0.79) (0.11)
50 4 M16
165 125 18 60.3 61.5 20 20 2.9
(7.28) (5.71) (0.71) (3.00) (3.05) (0.87) (0.87) (0.11)
65 8 M16
185 145 18 76.1 77.5 22 22 2.9
(7.87) (6.3) (0.71) (3.50) (3.56) (0.94) (0.94) (0.13)
80 8 M16
200 160 18 88.9 90.5 24 24 3.2
(9.25) (7.48) (0.87) (4.50) (4.57) (1.02) (0.94) (0.14)
100 8 M20
235 190 22 114.3 116 26 24 3.6
(10.63) (8.66) (1.02) (5.50) (5.57) (1.10) (1.02) (0.16)
125 8 M24
270 220 26 139.7 141.6 28 26 4
(11.81) (9.84) (1.02) (6.63) (6.71) (1.18) (1.10) (0.18)
150 8 M24
300 250 26 168.3 170.5 30 28 4.5
(14.76) (12.60) (1.18) (8.63) (8.72) (1.42) (1.34) (0.25)
200 12 M27
375 320 30 219.1 221.5 36 34 6.3
(17.72) (15.16) (1.30) (10.75) (10.89) (1.65) (1.50) (0.28)
250 12 M30
450 385 33 273 276.5 42 38 7.1
(20.28) (17.72) (1.30) (12.75) (12.89) (2.05) (1.65) (0.31)
300 16 M30
515 450 33 323.9 327.5 52 42 8
Canada www.HYDAC-NA.com
HYDAC CORPORATION HYDAC CORPORATION HYDAC CORPORATION
14 Federal Road Sales Office Sales Office
Welland, Ontario, Canada L3B 3P2 5160 75 Street NW Montreal, Québec, Canada J2M 1K9
+1.905.714.9322 Edmonton, Alberta, Canada T6E 6W2 +1.877.539.3388
+1.780.484.4228
Mexico www.HYDACmex.com
HYDAC INTERNATIONAL SA de CV
Calle Alfredo A Nobel No 35
Col Puente de Vigas
Tlalnepantla, Edo Mexico
CP 54090
Mexico
+011.52.55.4777.1262
© Copyright 2019 HYDAC TECHNOLOGY CORPORATION • Filter Catalog PN#02081318 / 07.19 / FIL190.2109