Performance and Durability

for High-Temperature GC
Agilent J&W high-temperature GC columns and consumables
What Is High-Temperature
Gas Chromatography?
High-temperature
BP C number GC (HT-GC) is the
D 7096
D 3710
analysis of IPcompounds
D 2887 D 6417 D 7500
IP 406 D 7213 D 6352
507 D 7169
IP 545
with boiling points in the
D 5399 IP 480
500 to 800 °C range.
LPG
1 Light naphtha It can also applyD to 7398any GC analysis with a final oven temperature
DIN 51435
Heavy naphtha

between
650 °F/345 °C350
20 and 450 °C.
Kerosene

Light gasoline

Simulated Distillation
Vacuum gas oil (SimDis) is a typical HT-GC method for determining the boiling
650 °F/345 °C 40

point distribution of petroleum products. However, there are many other HT-GC
1140 °F/ 620 °C 60

applications,
1247 °F/ 675 °C 80
including biodiesel, polymer additives, nonionic surfactants, waxes, and
certain food100
1328 °F/ 720 °C
applications.
Bright stock
High vacuum
HT-GC applications

1382 °F/ 750 °C 120 Residual

@ !"#"$%&'()&'*+,
HT- GC applications
-.%/0&&&&&&&&&&&&&&&&&&&&&&&&&&&&&1234.503%.6/.%7&/680/&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&90#"/6%2:7&$%6%0;03%&<.4&6==/.>68/0?

Fused Silica
HT-Fused Silica
UltiMetal
-50 0 100 200 300 350 400 450 500

Gases
Volatiles GC analysis temperatures
Semivolatiles
by application
Finished Petroleum Products
Crude and Waxes (SimDis) C50–C120
Industrial Chemicals Additives,
Flavors and Fragrances antioxidants, dyes

Glycerides and Sterols Triglycerides

D 7096 D 2887 D 6417 D 7500 IP 507 D 7169


BP C number D 3710 IP 406 D 7213 D 6352 IP 545
LPG D 5399 IP 480
1 Light naphtha D 7398 DIN 51435
Heavy naphtha
Kerosene
650 °F/345 °C 20
Light gasoline

650 °F/345 °C 40
Vacuum gas oil
ASTM and other
1140 °F/ 620 °C 60
SimDis methods

1247 °F/ 675 °C 80

1328 °F/ 720 °C 100 Bright stock HT-GC applications


High vacuum

1382 °F/ 750 °C 120 Residual

@ !"#"$%&'()&'*+,
HT- GC applications
-.%/0&&&&&&&&&&&&&&&&&&&&&&&&&&&&&1234.503%.6/.%7&/680/&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&90#"/6%2:7&$%6%0;03%&<.4&6==/.>68/0?

Fused Silica
3
HT-Fused Silica
UltiMetal
-50 0 100 200 300 350 400 450 500
Agilent J&W High-Temperature
GC Columns Can Take the Heat

Applications operating between 360 and 400 °C often use a high-temperature, polyimide-coated, fused silica GC column
to meet the challenges of routine analysis. However, if the columns are heated above 360 °C for an extended time, the
polyimide will begin to flake. And that leaves the column brittle and prone to breakage.
Agilent J&W high-temperature GC columns feature a special high-temperature polyimide that can operate in temperatures
of up to 400 °C. They are engineered to combine robustness with advanced surface deactivation for improved column
lifetime and peak shape. In addition, proprietary Agilent J&W technology enhances stationary phase bonding for low bleed
performance at high temperatures.

Agilent versus the competition.


After operating at 400 °C for
25 hours, the competitor’s 5ht
GC column flaked off, showing
signs of depolymerization. The
coating on the Agilent DB-5ht
GC column remained uniform,
and the column maintained
its flexibility.

Why are most high-temperature columns short with thin films?


–– High molecular weight compounds: Reasonable retention times for these compounds can only be achieved if the
phase ratio (β) of the GC column is large. A large phase ratio is only possible with thin-film stationary phases.
–– Bleed: Acceptable bleed levels depend on several criteria, such as temperature, column length, and film thickness.
Since high bleed is almost inevitable at high temperatures, shorter column lengths and thinner films are necessary
to keep bleed at adequate levels for most applications.

4
Performance and
Durability That Outperform
the Competition

Tridecane An Agilent DB-5ht column and a competitor’s


4000
5ht column were held at 400 °C for 100 hours
3500
to evaluate performance and stability. In just
3000
Agilent DB-5ht 15 hours, the competitor’s column drastically
2500
plates/meter

lost its performance, measured by plates/


2000
120 analyses meter, despite claiming a 430 °C maximum
1500
temperature stability. The Agilent DB-5ht
1000

500
Competitor X-5ht column remained stable—even after 40+
0 hours at the same conditions.
0 20 40 60 80 100 120
Time at 400 °C (hours)

30 m x 0.25 mm x 0.10 mm after 120 hours at 400 °C


A closer look at the chromatograms after
pA 0
90
80
40 hours at 400 °C. With the competitor’s
70
60 5ht column, peak tailing is visible for most
50 3
40
30
1
2 4 5
Competitor X-5ht analytes. Tailing of an alkane, such as
20 30 m x 0.25 mm x 0.10 µm
10
6 7
8 n-tridecane, proves that the active sites that
00 2
0 1
4 6 8 10 12 14 16 18 min
cause peak tailing are due to stationary
pA
90
80 2 3
phase breakdown. The Agilent DB-5ht column
70
4 5
60 shows no sign of phase degradation under
50
40
30
6 7
8 Agilent DB-5ht the same conditions, proving that the phase
20 30 m x 0.25 mm x 0.10 µm
10 is stable after prolonged periods at 400 °C.
0
0 2 4 6 8 10 12 14 16 18 min

@ !"#"$%&'()&'*+, -.%/0&&&&&&&&&&&&&&&&&&&&&&&&&&&&&1234.503%.6/.%7&/680/&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&90#"/6%2:7&$%6%0;03%&<.4&6==/.>68/0?

Peak Identification
0. Methane 3. 2,6-Dimethylphenol 6. 1-Decanol
1. Decane 4. 2,6-Dimethylaniline 7. Tridecane
2. 1-Octanol 5. Naphthalene 8. Methyl decanoate

Can I heat my DB-1ht or DB-5ht column to 430 °C?


Yes. If you operate your GC column beyond 400 °C, it will not immediately be ruined. However, the column will bleed
more, and its overall lifetime will be shorter.
Every GC column supplier sets upper temperature limits according to their internal specifications. Agilent GC column
temperature limits are defined by the industry’s most rigorous evaluations to ensure superior quality and column lifetime.
For a more in-depth look, consult application note 5994-1013EN.

5
Durable and Inert Stainless
Steel GC Columns
for Extreme Conditions

Traditional GC columns are made from fused silica with a polyimide outer coating. This construction is ideal for most
applications below 350 to 360 °C, as fused silica offers flexibility, strength, and easy installation. A special fused silica tubing
is necessary for operations up to 400 °C. However, even high-temperature fused silica will degrade above 400 °C—leading to
polyimide burn off, column breakage, and productivity loss.
For applications above 400 °C, stainless steel GC columns offer better durability and ruggedness than fused silica tubing.
Agilent J&W UltiMetal and ProSteel GC columns last long even under extreme conditions. Their deactivation renders the
stainless steel inert and enhances stationary phase bonding—lowering column bleed and improving detection limits.
The result is a GC column with the best combination of high resolution and long column lifetime.

Agilent J&W stainless steel GC columns offer comparable efficiency to fused silica GC columns
Advanced phase chemistry stabilizes the stationary phase of Agilent UltiMetal and ProSteel columns without
limiting chromatographic performance.

Peak Identification
0 1
0. Methane 3. 2,6-Dimethylphenol 6. 1-Decanol
2 3
1. Decane 4. 2,6-Dimethylaniline 7. Tridecane
4 5 2. 1-Octanol 5. Naphthalene 8. Methyl decanoate

6
7
8 J&W VF-5ht Fused Silica

J&W VF-5ht UltiMetal

0 2 4 6 8 10

Fused silica and UltiMetal VF-5ht columns after 5 hours at 430 °C.

6
Excellent resolution of high-boiling compounds: a stabilized liquid phase coating
ensures low bleed and low baselines
Improved chromatography for high-temperature applications. Agilent stainless steel GC columns use
a proprietary stabilization technology that maximizes signal-to-noise ratios for better detection limits
with high boilers, less detector contamination, and faster stabilization.

Polywax 655
140

120

100 Brand X
∆= 87.0 pA
80

60

40
J&W DB-HT SimDis
∆= 17.3 pA
20

0 5 10 15 20 25 30 35 40 45 min

Comparison of Agilent DB-HT SimDis and Competitor X SimDis columns for polywax 500 analysis. The Agilent column displayed very low bleed
and low baseline, even with a 430 °C final temperature.

Columns: Brand X Stainless Steel SimDis and Agilent J&W DB-HT SimDis ProSteel 5 m x 0.535 mm x 0.15 mm
Carrier: Helium, constant flow, 18 mL/min
Oven: 40 °C (0 min), Ramp 10 °C/min to 430 °C (20 min)
Inlet: MMI Splitless mode, 100 °C (0.5 min), Ramp 10 °C/min to 430 °C

Which injector should I use for high-temperature GC?


Programmable temperature vaporizing (PTV) and cool on-column inlets are best for HT-GC analysis. That’s because
they allow the solute bands to refocus before separation in the GC column.
Although splitless and direct injection are possible with HT-GC, you should avoid solute discrimination in the inlet.
If you must use splitless or direct injection, keep your injector temperature as hot as possible, use a high-boiling
solvent, and minimize your injection volume.

7
The Agilent J&W
High-Temperature
GC Column Portfolio

With a wide range of general purpose and specialty columns, Agilent high-temperature GC columns make method
development fast and easy.

Category Agilent J&W GC Column Max. Temp. (°C)

DB-1ht 400 °C
DB-5ht 400 °C
General purpose columns
VF-5ht 400 °C
DB-17ht 340/365 °C
High-Temperature Fused Silica
CP-SimDist 400 °C
Select biodiesel 400 °C
Specialty columns
Select mineral oil 375/400 °C
CP-TAP CB for triglycerides 380 °C
General purpose columns VF-5 UltiMetal 450 °C
DB-HT SimDis 430 °C
Stainless Steel CP-SimDist UltiMetal 450 °C
Specialty columns
Select biodiesel UltiMetal 400 °C
Select mineral oil UltiMetal 375/400 °C

Which column best fits your application?


DB-1ht and DB-5ht VF-5ht DB-17ht
–– Nonpolar, 100% dimethylpolysiloxane –– Nonpolar, (5% phenyl)- –– Midpolar, (50% phenyl)-methylpolysiloxane
and (5% phenyl)-methylpolysiloxane methylpolysiloxane –– Extended upper temperature limit of 365 °C
–– Extended temperature limit of 400 °C –– Ideal for high-boiling compounds –– High-temperature, polyimide-coated,
–– High-temperature, polyimide-coated, –– Ultralow bleed at high temperatures fused silica tubing
fused silica tubing –– Optimized sensitivity and –– Improved resolution for triglycerides
–– Excellent peak shape and faster accuracy for compounds with –– Ideal for conformational analyses
elution times for high boilers high molecular weight

8
Application examples: low-resolution boiling point distribution

Analysis of polywaxes using a DB-HT SimDis column

C92
C94
200
C96

175
Polywax 500 C98
C100
C102
150 C104
C106
C108
125
Polywax 655 C110
C112
C114
100
Polywax 1000 36 37 38 39 40 41
75

50

25

0 10 20 30 40 50 min

Column advantages: Column: 


5 m x 0.53 mm x 0.15 mm DB-HT SimDist
(p/n 145-1001)
–– “Boiling point” phase for high-temperature SimDis Carrier: Helium, constant flow, 18 mL/min

–– Distillation range of C6 to C110+ with a 430 °C upper temperature limit Oven: 


4 0 °C (0 min), Ramp 10 °C/min to 430 °C
(20 min)
–– 100% Dimethylpolysiloxane MMI Splitless mode, 100 °C (0.5 min),
Inlet: 
Ramp 10 °C/min to 430 °C
–– Durable stainless steel tubing
–– Low bleed, even at 430 °C

Worried about cutting an Agilent J&W stainless steel capillary GC column? Don’t be.
You might think that stainless steel columns are difficult to cut, based on a bad experience with a competitor’s column.
However, with a little practice, Agilent J&W stainless steel columns are no more difficult to cut than a fused silica
column—with no additional tools needed.
Our step-by-step guide shows you just how easy it is.

9
Application examples: higher resolution high-temperature GC up to 400 °C

Analysis of hydrocarbons in beeswax using a DB-5ht column

pA

180

160
400 °C
140

C42
120

100

80 C26
C28
60 C24 C30 C44
C48
90 °C C32 C46
40
C34 C50
C22
C52
20

0
0 2 4 6 8 10 12 14 16 18 min

Column: 
Agilent J&W DB-5ht (p/n 122-5711)
15 m x 0.25 mm x 0.10 mm
N !=I=&C(57J(549K +L M
E:(((((((((((((((((((((((((((((!I'$1"C(:)"*',1"C'#$(((((((((((((((((
Carrier: Helium, constant flow, 1 mL/min
Oven: 90 °C (1.0 min), ramp 20 °C/min to 400 °C (30 min)
Inlet: MMI Split mode, split ratio 20:1, 300 °C (12 min), ramp 20 °C/min to 400 °C
Inlet liner: Ultra Inert, split, low pressure drop, glass wool (p/n 5190-2295)
IGC/FID: Agilent 7890B GC equipped with FID

Triton Analytics Corporation testimonial


Watch as industry expert Dan Villalanti, PhD, chairman of ASTM
Committee D02.04.0K on Correlative Methods and referee for Journal
of Chromatographic Science, shares his 30+ years of experience with
Agilent products.
www.agilent.com/chem/high-temp-video

10
Application example: higher resolution high-temperature GC up to 450 °C

High-temperature GC analysis of Fischer–Tropsch Reaction products

pA C40
440 °C
350

300
C50

250

200 C60

150 C70

100 90 °C C80

50 C90
C30

0
10 20 30 40 50 min

Column: VF-5ht UltiMetal, 30 m x 0.32 mm x 0.10 μm (p/n CP9096)


Sample volume: 1 μl
Carrier gas: Hydrogen, constant flow, 2.5 mL/min
Injector: Cool on-column
Temperature: 90 °C, 25 °C/min, 150 °C, 8 °C/min, 440 °C (15 min)
Detector: FID, 440 °C

Column advantages (VF-5ht):


–– Nonpolar, (5% phenyl)-methylpolysiloxane
–– Enhanced stability improves column longevity and reduces downtime
–– Optimized sensitivity and accuracy for analyzing compounds with high molecular weight
–– Identical selectivity to VF-5ms

11
Choosing the Right GC Column:
Are High-Temperature GC
Columns Ideal for Semivolatiles?

No. Analyzing semivolatiles is not considered a high-temperature application. Although you can use high-temperature
GC columns to analyze semivolatiles, there are other choices that offer improved inertness, better selectivity, and extended
column lifetime. Most semivolatiles have boiling points below 500 ºC (925 ºF), and can be analyzed using GC columns with
a 350/360 ºC upper temperature limit. Column options like Agilent J&W Ultra Inert GC columns deliver consistent inertness
performance to ensure better peak shape and sensitivity for trace-level analysis of semivolatiles. Other columns are
specifically designed for resolving critical isomers for faster and more reliable analysis of challenging semivolatiles.

7 11

Peak Compunds Ions


9 13
1. Benzo[g,h,i]fluoranthene 226
10 12 2. Benzo[c]phenanthrene 228
2
3. Benz[a]anthracene 228
3 6 4. Cyclopenta[c,d]pyrene 226
5
5. Triphenylene 228
6. Chrysene 228
1 7. Benzo[b]fluoranthene 252
8. Benzo[k]fluoranthene 252
4 9. Benzo[j]fluoranthene 252
10. Benzo[a]fluoranthene 252
11. Benzo[e]pyrene 252
12. Benzo[a]pyrene 252
13. Perylene 252
23 25 27 29 31 33 35 37min

PAHs analyzed on a Select PAH column.

Technique: GC/MS Temperature: 


70 °C (0.5 min), 60 °C/min, 210 °C, 5 °C/min, 250 °C, 10 °C/min,
280 °C (3 min), 10 °C/min, 350 °C (3 min)
Column: 
S elect PAH, 30 m x 0.25 mm, df = 0.15 μm
(p/n CP7462) Carrier gas: Helium, constant flow, 2 mL/min
Sample conc: Approx 1 μg/mL Injection: 100 °C, 180 °C/min, 300 °C (20 min), splitless
Injection volume: 1 μL Detection: Triple Quad MS, EI in SIM, source 275 °C, transfer line 300 °C

Product spotlight: Agilent Inert Flow Path


Agilent Ultra Inert GC columns and consumables deliver the inertness that today’s analyses demand. So you can
achieve lower detection limits and more accurate data for semivolatiles such as pesticides, PAHs, and drugs of abuse.
To learn more, visit www.agilent.com/chem/inert

12
Higher Temperatures Demand Quality Consumables
In high-temperature GC analysis, it is important to reduce any possible source of leaks into the GC system. That’s because
oxygen damage can be rapid at high temperatures, resulting in massive bleed and faster column degradation.
You can reduce the presence of oxygen in the carrier gas—and minimize outgassing and leaks—using the proper
high-temperature GC consumables.

Here is what you’ll need for high-temperature applications above 350 °C:

Standard Applications < 350 °C High Temp Application

Advance Green septa


Long life septa BTO septa

Graphite ferrules
Graphite/Vespel ferrules UltiMetal ferrules

Fluorocarbon O-rings Graphite seals

Ultra Inert liners Standard liners

Carrier Gas Filter Carrier Gas Filter

Product spotlight: Agilent gas leak detector


Gas leaks can reduce column lifetime, especially with
high-temperature applications. The Agilent gas leak
detector makes it easy to quickly identify leaks in your
system, so you can minimize expensive downtime.
Take a closer look.

13
Ordering information

High-temperature fused silica GC columns

Description Part Number Description Part Number

DB-1ht DB-17ht

15 m x 0.25 mm, 0.1 µm, 7 in. 122-1111 5 m x 0.25 mm, 0.15 µm, 7 in. 122-1801
15 m x 0.25 mm, 0.1 µm, 5 in. 122-1111E 15 m x 0.25 mm, 0.15 µm, 7 in. 122-1811
30 m x 0.25 mm, 0.1 µm, 7 in. 122-1131 30 m x 0.25 mm, 0.15 µm, 7 in. 122-1831

15 m x 0.25 mm, 0.1 µm, 5975 LTM Toroid 222-1111LTM 30 m x 0.25 mm, 0.15 µm, 7890/6890 LTM module 122-1831LTM

30 m x 0.25 mm, 0.1 µm, 5975 LTM Toroid 222-1131LTM 15 m x 0.32 mm, 0.15 µm, 7 in. 123-1811

2 m x 0.25 mm, 0.1 µm, QuickProbe G3903-61006 30 m x 0.32 mm, 0.15 µm, 7 in. 123-1831

5 m x 0.32 mm, 0.25 µm, 7890/6890 LTM module 123-1102LTM 30 m x 0.32 mm, 0.15 µm, 5 in. 123-1831E

15 m x 0.32 mm, 0.1 µm, 7 in. 123-1111 60 m x 0.32 mm, 0.15 µm, 7 in. 123-1861

15 m x 0.32 mm, 0.1 µm, 7890/6890 LTM module 123-1111LTM Select mineral oil
30 m x 0.32 mm, 0.1 µm, 7 in. 123-1131
15 m x 0.32 mm, 0.1 µm, 7 in. CP7491
30 m x 0.32 mm, 0.1 µm, 5 in. 123-1131E
15 m x 0.32 mm, 0.1 µm, Intuvo CP7491-INT
30 m x 0.53 mm, 0.17 µm, 7 in. 125-1131
15 m x 0.32 mm, 0.1 µm, 7 in. 3/pk CP749103
DB-5ht 15 m x 0.32 mm, 0.1 µm, 7 in. 6/pk CP749106

20 m x 0.18 mm, 0.18 µm, 7 in. 121-5722 Select biodiesel


15 m x 0.25 mm, 0.1 µm, 7 in. 122-5711
10 m x 0.32 mm, 0.1 µm, 7 in. CP9077
15 m x 0.25 mm, 0.1 µm, 5 in. 122-5711E
15 m x 0.32 mm, 0.1 µm, 7 in. CP9079
30 m x 0.25 mm, 0.1 µm, 7 in. 122-5731
30 m x 0.32 mm, 0.25 µm, 7 in. CP9080
30 m x 0.25 mm, 0.25 µm, 7 in. 122-5732
30 m x 0.32 mm, 3 µm, 7 in. CP9083
30 m x 0.25 mm, 0.1 µm, 7890/6890 LTM module 122-5731LTM
CP-TAP CB for triglycerides
30 m x 0.25 mm, 0.1 µm, 5975 LTM toroid 222-5731LTM
15 m x 0.25 mm, 0.1 µm, w/ Smart Key for 8890 GC 122-5711-KEY 25 m x 0.25 mm, 0.1 µm, 7 in. CP7483

10 m x 0.32 mm, 0.1 µm, 7 in. 123-5701 25 m x 0.25 mm, 0.1 µm, Intuvo CP7483-INT

10 m x 0.32 mm, 0.1 µm, 7890/6890 LTM module 123-5701LTM


High-temperature stainless steel GC columns
15 m x 0.32 mm, 0.1 µm, 7 in. 123-5711
15 m x 0.32 mm, 0.1 µm, 5 in. 123-5711E
Description Part Number
30 m x 0.32 mm, 0.1 µm, 7 in. 123-5731
VF-5ht
30 m x 0.32 mm, 0.1 µm, 5 in. 123-5731E
5 m x 0.32 mm, 0.1 µm, Intuvo 123-57J1-INT 15 m x 0.25 mm, 0.1 µm, 7 in. CP9090
30 m x 0.2 mm, 0.1 µm, 7 in. CP9092
VF-5ht
CP-TAP CB for triglycerides
15 m x 0.25 mm, 0.1 µm, 7 in. CP9045
30 m x 0.25 mm, 0.1 µm, 7 in. CP9046 25 m x 0.25 mm, 0.1 µm, 7 in. CP7463

30 m x 0.25 mm, 0.1 µm, 5 in. CP9092I5 Select biodiesel


10 m x 0.32 mm, 0.1 µm, 7 in. CP9044 10 m x 0.32 mm, 0.1 µm, 7 in. CP9076
15 m x 0.32mm, 0.1 µm, 7 in. CP9047 15 m x 0.32 mm, 0.1 µm, 7 in. CP9078
30 m x 0.32mm, 0.1 µm, 7 in. CP9048
DB-HT Simulated Distillation
CP-Simulated Distillation
5 m x 0.53 mm, 0.15 µm, 7 in. 145-1001
10 m x 0.32 mm, 0.1 µm, 7 in. CP7521 5 m x 0.53 mm, 0.1 µm, 7 in. 145-1009
5 m x 0.53 mm, 0.17 µm, 7 in. CP7522
5 m x 0.53 mm, 0.88 µm CP7523
10 m x 0.53 mm, 0.1 µm, 7 in. CP7541

14
High-temperature GC consumables and accessories

Description Part Number

BTO septa

Inlet septa, bleed and temperature optimized 5183-4757


(BTO), non-stick, 11 mm, 50/pk
Inlet septa, bleed and temperature optimized 5183-4758
(BTO), non-stick, 5 mm, through-hole, 50/pk
Inlet septa, bleed and temperature optimized (BTO), 5183-4757-100
non-stick, 11 mm
Inlet septa, bleed and temperature optimized (BTO), 5190-3157
non-stick, 11 mm, 400/pk

Ultimetal Plus Flexible Metal ferrules

Flexible Metal ferrule, Ultimetal Plus, 0.4 mm id, G3188-27501


for 0.1 to 0.25 mm id. fused silica tubing, 10/pk
Flexible Metal ferrule, UltiMetal Plus, 0.5 mm id, G3188-27502 Gas filters
for 0.32 mm fused silica tubing, 10/pk
Flexible Metal ferrule, UltiMetal Plus, 0.8 mm id, G3188-27503 Description Part Number
for 0.53 mm id fused silica tubing, 10/pk
Flexible Metal ferrule, UltiMetal Plus, without hole, G3188-27504 Gas purifier startup kit:
to plug capillary flow technology fittings, 10/pk • Cartridge
• Base
G3440-60004
Flexible Metal Ferrule, UltiMetal Plus, for 0.25 and 0.32 mm id G3188-27505 • Wall/bench mounting hardware
UltiMetal column tubing, 10/pk • Return packaging
• Instructions
Flexible Metal ferrule, UltiMetal Plus, for 0.53 mm id UltiMetal G3188-27506
column tubing, 10/pk Recharged gas purifier cartridge G3440-69003

Graphite ferrules Gas Clean filter: Intuvo kit CP17995


Gas Clean filter: 7890 kit CP17988
Ferrule, 0.4 mm id, graphite, 0.05 to 0.25 mm column, 10/pk 500-2114
Gas Clean filter: 8890/8860 kit
Ferrule, 0.8 mm id, graphite, 0.45 to 0.53 mm column, 10/pk 500-2118 CP179880
(includes Gas Clean sensor)
Ferrule, graphite, 1 mm id, for 0.53 mm column, 10/pk 5080-8773 Replacement Gas Clean carrier gas kit CP17973
Ferrule, graphite, short, 0.5 mm id, 5080-8853
for 0.1 to 0.32 mm columns, 10/pk

Inlet seals

Inlet liner, O-ring, graphite, 6.35 mm id, 9.63 mm od, 10/pk 5180-4168 Gas leak detectors
Inlet liner, O-ring, graphite, for splitless liner, 0.062 in od, 10/pk 5180-4173
Description Part Number
Inlet liner, O-ring, FPM for high temperature PTV, 10/pk 5188-5311
Replacement sample probe filter, G3388-80001
Liners
for Agilent G3388 gas leak detector
Inlet liner, PTV, sintered glass, deactivated 5190-1426 Replacement reference port filter, G3388-80002
Inlet liner, PTV, high temperature 5190-1426 for Agilent G3388 gas leak detector

Inlet liner, PTV, high temperature, quartz, 3.4 mm id, 5188-5313 Electronic gas leak detector, handheld G3388B
713 µL, for G3505A
Inlet liner, PTV, multi baffle, deactivated 5183-2037
Inlet liner, PTV, single baffle, glass wool, deactivated 5183-2038
Cool on-column (COC) inlets
Inlet liner, PTV, single baffle, deactivated 5183-2036
View part numbers and descriptions
Splitless, single taper, deactivated, dimpled, 200 µL 5190-2296
Splitless, straight, deactivated, quartz, 250 µL, 5/pk 5183-4703 Programmable temperature vaporizing (PTV) inlets
Splitless, straight, deactivated, quartz, 250 µL, 25/pk 5183-4704
View part numbers and descriptions
Splitless, double taper, deactivated, 800 µL, 5/pk 5183-4705
Splitless, double taper, deactivated, 800 µL, 4 mm, 5/pk 5183-4706
Splitless, double taper, deactivated, 800 µL, 4 mm, 100/pk 5190-2272
Splitless, single taper, deactivated, 900 µL, 4 mm, 25/pk 5183-4696
Splitless, single taper, deactivated, 900 µL, 4 mm, 5/pk 5183-4695
Splitless, straight, 900 µL, 4 mm, 5/pk 210-3003-5

15
Agilent CrossLab services. From insight to outcome.
CrossLab is an Agilent capability that integrates services and consumables to
support workflow success and important outcomes like improved productivity
and operational efficiency. Through CrossLab, Agilent strives to provide insight in
every interaction to help you achieve your goals. CrossLab services include method
optimization, flexible service plans, and training for all skill levels. We have many
other products and services to help you manage your instruments and your lab for
best performance.

Learn more about Agilent CrossLab, and see examples of insight that leads to great
outcomes, at www.agilent.com/crosslab

Learn more:
www.agilent.com/chem/gc-columns

Buy online:
www.agilent.com/chem/store

Get answers to your technical questions and


access resources in the Agilent Community:
community.agilent.com

U.S. and Canada


1-800-227-9770
agilent_inquiries@agilent.com

Europe
info_agilent@agilent.com

Asia Pacific
inquiry_lsca@agilent.com

This information is subject to change without notice.

© Agilent Technologies, Inc. 2019


Published in the USA, September 26, 2019
5994-1384EN

You might also like