Academic Structure 31-44 Slab Details 2nd Floor
Academic Structure 31-44 Slab Details 2nd Floor
°
°
.6
c)FDN 50mm d) COL. 40mm.
.0
°
87
.6
°
87
°
.4
.3
86
4. CONCRETE MIX SHALL BE M-25.
86
90
2°
.
°
°
86
1°
5. CEMENT MORTAR SHALL BE 1:6 FOR 230 TH BRICK WORK AND 1:4
.3
.6
7°
.
5°
85
88
85
°
°
.6
.
.
115TH BRICK WORK.
.1
84
84
87
84
°
.6
°
.9
6. BRICKS OF CLASS DESIGNATION 75 HAVING MINIMUM CRUSHING
83
85
STRENGTH OF 75 kg/Cm2 SHALL BE USED.
7. REINF. SHALL BE :- a) HIGH STRENGTH DEFORMED STEEL BARS OF
GRADE Fe 500 CONFORMING TO IS: 1786- 1985 (CHAR. STRENGTH 500
N/mm2 ) OR
X30 X31 X32 X33 X33' X34 ALL STEEL REINF. SHALL BE HIGH STRENGTH DEFORMED BARS CTD/
X35 X36 X37 X38 X39 TMT CONFIRMING TO I.S. 1786 AND HAVING A YIELD STRENGTH OF
X40 X41 500 N/mm2.
X42 X43 8. IN PORTION MARKED 'Z' (SHOWN IN TYP. SECTION THROUGH COL.)
X44
OF THE COL. SAME LINK SHALL BE PROVIDED FOR ZONE 'h1' IN
CASE OF EXTERNAL COL. & FOR ZONE 'h2' IN CASE OF INTERNAL
COLUMN, FACILITATE IS PLACING THESE LINKS MAY BE PROVIDED
B7 B7 B7 'U' SHAPED.
B7 B7
B7
B7
B7
B7
B7
B7
B7
B7 9. THE FOUNDATION DESIGN IN THIS DRAWING IS BASED ON SOIL
B7
B7
B7
B7
B7
B7
B7
B7
B8 TESTING REPORT SUBMITTED
B7
B8 B3 B7
B7
B9
a B2 B7 10. FOUNDATION HAS BEEN DESINED CONSIDERING SBC 250KN/M2 AT
B7
B7
B8
B7
B7
B7
B9 c B3 B7 DEPTH 2.0 M
B3
B7
B2
B10
11. THIS BUILDING IS DESIGNED FOR G+4 STOREY ONLY. AAC BLOCK
B7
a
B7 WILL BE USED AS IN FILL WALL MASONRY
B4
Y8
B4
B9
12. THIS IS GFC BUIDLING SUBJECTED TO THE APPROVAL BY THE
B4
B9 S2
B10
a S1
B4
B10
b STAIRCASE S2 CLIENT.
B10
B9 B9 B2 13.ALL ELECTRICAL AND PHE SHAFTS WILL BE AS PER ARCHITECTURAL
S1
B9 B9 LIFT SB1
S1 S1
SB1 S1 S1 S1 B2
c c
B3
c
B3 Y7 DRAWINGS.
LIFT
B9 b 14. THE DEPTH OF BEAMS AND INTEGRATED DRAWING OF HVAC
SB1 c
B4 SHOULD BE COMPATIBLE WITH HEIGHT REQUIREMENT OF FLOORS.
B9 B9
F.H.C
c Y6
c c S2 c
c c
B4
B4
c
B4
c
B4
c
B4
a Y5
B4
S1
B9
S4
B9
B4
S4 SB2 S1
B4
c SB3 S4 S1
a
S2
B6 B8 B8
B4
c B8
B2
b B6
c B2 B2
B12
B6
B12
S3 c B6
b
B12
S3
Y4
B12
c S3
B4
B12
B8 B8 B8 c S3
B8
B11 B8
B11
B1
B3
B3
B8
a Y3
B1
B1
a
B1
a S4
B1
c c c c c c c S1
B1
B4 c
c
B5
SB1 c c
SB1
B5
S1 S1 S1 S1 S1 SB1 B3
S1 SB1 c
S1 S1 B10
b S1 SB1 c
S4 a S1
SB1
B1
B1
B1
S1 S1
B1
SB3 b Y2
B1
B1
S1
B1
B1
B8 B8
B8
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7 B8
B7
B7
B7 B7 B7 B7 B11 B8
B7
B7
B7
B7
B8
B7
B7 B7
B7
B7
B7
B7
B7 B8
B7 Y1
Y'
3-12 0.2L1
0
75
SLAB R/F
3-12
(ALAROUND) Bottom Reinforcement
TOP & BOTTOM
L2
L1 N. B. C. C.
I.S.O 9001
Ld
NBCC
TYPICAL SLAB SECTION SHOWING CONSULTANCY DIVISION
ADDITIONAL 1 NO.- 12
TOP & BOTTOM (DIAGONAL BAR) PROVIDE DISTRIBUTION REINF- 8 @200c/c
ALAROUND WHEREVER REQUIVED
3-12 BAR